Icom IC-2720H Instruction Manual

download Icom IC-2720H Instruction Manual

of 96

Transcript of Icom IC-2720H Instruction Manual

  • 8/8/2019 Icom IC-2720H Instruction Manual

    1/96

    INSTRUCTION MANUAL

    i2720H

    DUAL BAND FM TRANSCEIVER

    This device complies with Part 15 of the FCC rules. Operation is sub-ject to the following two conditions: (1) This device may not causeharmful interference, and (2) this device must accept any interferencereceived, including interference that may cause undesired operation.

  • 8/8/2019 Icom IC-2720H Instruction Manual

    2/96

    i

    FOREWORDThank you for purchasing this Icom product. The IC-2720H

    VHF/UHF FM TRANSCEIVER is designed and built with Icoms su-

    perior technology and craftsmanship. With proper care, this

    product should provide you with years of trouble-free opera-

    tion.

    We want to take a couple of moments of your time to thankyou for making your IC-2720H your radio of choice, and hopeyou agree with Icoms philosophy of technology first. Manyhours of research and development went into the design ofyour IC-2720H.

    DFEATURES

    V/V, U/U simultaneous receive capability

    Independent controls for each left and right

    bands

    Separate controller for flexible installation

    50 W* of high transmit output power*VHF band; 35 W for UHF, 25 W for Taiwan version

    Remote control microphone standard

    New DMS (Dynamic Memory Scan) system

    IMPORTANTREAD ALL INSTRUCTIONS carefully and completelybefore using the transceiver.

    SAVE THIS INSTRUCTION MANUAL This in-

    struction manual contains important operating instructions forthe IC-2720H.

    EXPLICIT DEFINITIONS

    WORD DEFINITION

    RWARNING!

    CAUTION

    NOTE

    Personal injury, fire hazard or electric shock

    may occur.

    Equipment damage may occur.

    Recommended for optimum use. No risk of

    personal injury, fire or electric shock.

    Icom, Icom Inc. and the logo are registered trademarks of IcomIncorporated (Japan) in the United States, the United Kingdom, Ger-

    many, France, Spain, Russia and/or other countries.

  • 8/8/2019 Icom IC-2720H Instruction Manual

    3/96

  • 8/8/2019 Icom IC-2720H Instruction Manual

    4/96

  • 8/8/2019 Icom IC-2720H Instruction Manual

    5/96

  • 8/8/2019 Icom IC-2720H Instruction Manual

    6/96

    I

    QUICK REFERENCE GUIDE

    I InstallationD Installation methods Single body installation

    Optional MB-85 COMBINATION BRACKET is necessary to

    mount the controller to the main unit. (20 cm; 778 separa-

    tion cable is supplied with the bracket.) The supplied mounting bracket (or optional MB-17A) can be

    used for the main unit installation.

    Remote installation

    The supplied MB-84 REMOTE CONTROLLER BRACKET and

    OPC-1155 SEPARATION CABLE can be used for installation.

    Optional OPC-1156 SEPARATION CABLE (3.5 m; 11.5 ft) isavailable for extend the separation cable.

    Optional MB-65 MOUNTING BASE is available for increasing

    front panel mounting possibilities.

    Optional OPC-440 MICROPHONE CABLE (5.0 m; 16.4 ft) and

    OPC-647 (2.5 m; 8.2 ft) are available to extend the micro-

    phone cable. Optional OPC-441 SPEAKER CABLE (5.0 m; 16.4 ft) is avail-

    able to extend the speaker cable.

    Main body

    Front panelTransceiver

  • 8/8/2019 Icom IC-2720H Instruction Manual

    7/96

    II

    QUICK REFERENCE GUIDE

    D LocationSelect a location which can support the weight of the trans-ceiver and does not interfere with driving. We recommend the

    locations shown in the diagram below.

    NEVER place the transceiver or remote controller where nor-

    mal operation of the vehicle may be hindered or where it

    could cause bodily injury.NEVER place the transceiver or remote controller where air

    bag deployment may be obstructed.

    DO NOT place the transceiver or remote controller where hot

    or cold air blows directly onto it.

    AVOID placing the transceiver or remote controller in direct

    sunlight.

    D Using the mounting bracketqDrill 4 holes where the mounting bracket is to be installed. Approx. 5.56 mm (14) when using nuts; approx. 23 mm (18)

    when using self-tapping screws.

    w Insert the supplied screws, nuts and washers through the

    mounting bracket and tighten.

    eAdjust the angle for your suitable position.

    25

    Nut

    Spring washer

    When usingself-tappingscrews

    Flat washerMounting nut

    Mountingbracket

    ; ;@ @ ; ;Q Q ;@;Q;@;Q;@;Q

    Controller

    Main unit

    Main unit

    Main unit

    Quickreferenceguide

  • 8/8/2019 Icom IC-2720H Instruction Manual

    8/96

    III

    QUICK REFERENCE GUIDE

    DMB-84 installationThe supplied MB-84 REMOTE CONTROLLER BRACKET is usedfor separate installation.

    qDrill 2 holes where the bracket is to be installed. Approx. 4 mm (18) when using nuts; approx. 12 mm (116)

    when using self-tapping screws.

    wAttach the remote controller to the MB-84 and tighten the

    controller using with the supplied screws.

    eTighten the controller with bracket.

    Using the optional MB-65

    MB-84(supplied)

    OptionalMB-65

    Adjust the view-ing angle formaximum visibili-ty of the functiondisplay.

    MB-84

    MB-84

    Over-head mounting

    Standard mounting

    Remotecontroller

    Suppliedscrews

    Suppliedscrews

    Self-tappingscrews

    Remote

    controller

    Nut

    Springwasher

    Flatwasher

  • 8/8/2019 Icom IC-2720H Instruction Manual

    9/96

    IV

    QUICK REFERENCE GUIDE

    D Optional MB-85 installationWhen using the optional MB-85 (COMBINATION BRACKET), youcan install the control head of the IC-2720H in one of 2 meth-

    ods. A 20 cm (778) remote control cable is supplied for con-nection, and connect the cable before attaching the bracket to

    the main unit is recommended.

    Example 1 Example 2Quickreferenceguide

  • 8/8/2019 Icom IC-2720H Instruction Manual

    10/96

    V

    D Separation cable connectionA separation cable (3.5 m; 11.5 ft) is supplied with the IC-2720H.

    Connect the controller and the main unit using with the sepa-

    ration cable as follows.

    IMPORTANT! For the USA version

    A ferrite core is supplied within the separation cable. Connect

    the cable connector with the ferrite core into the main unit

    [CONTROLLER] socket as below.

    DMicrophone connectionTwo microphone connectors are available for the IC-2720Hone is on the controller side panel, and another is on the main

    unit front panel.

    Connect the supplied microphone to either the desired con-

    nector as illustrated below.

    Controller

    Main unit

    Ferrite core

    Controller Main unit

    See IMPORTANT! below.

    QUICK REFERENCE GUIDE

  • 8/8/2019 Icom IC-2720H Instruction Manual

    11/96

    VI

    QUICK REFERENCE GUIDE

    D Battery connectionRWARNING NEVER remove the fuse holders from theDC power cable.

    NEVER connect the transceiver directly to a 24 V battery. DO NOT use the cigarette lighter socket for power con-

    nections. (See p. 6 for details)

    Attach a rubber grommet when passing the DC power cable

    through a metal plate to prevent a short circuit.

    CONNECTING TO A DC POWER SOURCE

    D DC power supply connectionUse a 13.8 V DC power supply with at least 15 A capacity.

    Make sure the ground terminal of the DC power supply is

    grounded.

    CONNECTING TO A DC POWER SUPPLY

    See p. 74 for fuse replacement.

    DC powersupply 13.8 V

    to anACoutlet

    Fuses20 Ablack

    red

    IC-2720H

    IC-2720H

    Fuses20 A

    blackred

    12 V

    Grommet

    NOTE:Use terminals for thecable connections.

    WARNING!NEVERremove the

    fuse holders.

    Crimp Solder

    12 Vbattery

    SuppliedDC power cable

    + red_ black

    Qui

    ckreferenceguide

  • 8/8/2019 Icom IC-2720H Instruction Manual

    12/96

    VII

    QUICK REFERENCE GUIDE

    D Antenna installation Antenna locationTo obtain maximum performance from the transceiver, select

    a high-quality antenna and mount it in a good location. A non-

    radial antenna should be used when using a magnetic mount.

    Antenna connectorThe antenna uses a PL-259 connector.

    PL-259 CONNECTOR

    q Slide the coupling ring

    down. Strip the cable

    jacket and soft solder.

    w Strip the cable as shown

    at left. Soft solder the cen-

    ter conductor.

    e Slide the connector body

    on and solder it.

    r Screw the coupling ring

    onto the connector body.

    (10 mm 38 in)

    NOTE: There are many publications covering proper an-

    tennas and their installation. Check with your local dealer

    for more information and recommendations.

    30 mm

    10 mm (soft solder)

    10 mm

    12 mm

    solder solder

    Softsolder

    Coupling ring

    To antenna

    Roof-mount antenna

    (Drill a hole or use a magnetic mount.)

    Gutter-mount antenna

    Trunk-mountantenna

  • 8/8/2019 Icom IC-2720H Instruction Manual

    13/96

    VIII

    QUICK REFERENCE GUIDE

    I Your first contactNow that you have your IC-2720H installed in your car or

    shack, you are probably excited to get on the air. We would

    like to take you through a few basic operation steps to make

    your first On The Air an enjoyable experience.

    1. Turning ON the transceiver

    Before powering up your IC-2720H, you may want to make

    sure the audio volume and squelch level controls are set in

    910 oclock positions.

    Although you have purchased a brand new transceiver, some

    settings may be changed from the factory defaults because

    of the QC process. Resetting the CPU is necessary to start

    from factory default.

    While pushing both bands [M/CALLMW], push [PWR] for1 sec. to reset the CPU.

    2. Selecting the main band

    The IC-2720H displays 2 frequencies on left and right bands

    simultaneously. However, transmission, some switches and

    microphone keys operation are accepted for the main band

    only.

    Push the desired bands (left or right) [MAINBAND] to se-lect the main band.

    Q appears for the main band.

    Using the HM-133You can select the main band from the HM-133.

    MAIN

    T X

    MAIN

    T X

    M M

    MAIN

    T X

    MAIN

    T X

    M M

    Push

    Push again

    Push the desired bands[MAINBAND]

    [M/CALLMW]

    While pushing both [M/CALLMW], turn power ON.

    [M/CALLMW]

    Set both [VOL] and [SQL] controls to 910 oclock positions.

    Qui

    ckreferenceguid

    e

  • 8/8/2019 Icom IC-2720H Instruction Manual

    14/96

    IX

    QUICK REFERENCE GUIDE

    3. Selecting the operating frequency band

    The IC-2720H has 2 m and 70 cm bands for each left and

    right band. The operating band can be exchanged between

    them, and the same bands, V/V and U/U settings are also

    possible.

    Push the desired bands (left or right) [MAINBAND] for1 sec. then rotate the appropriate bands [DIAL]. Push the [MAINBAND] momentarily to return to frequency indi-

    cation.

    4. Tune the frequency

    The tuning dial will allow you to dial in the frequency you want

    to operate. Pages 13 and 14 will instruct you on how to set

    the tuning speed.

    Using the HM-133You can directly enter the frequency with the HM-133 keypad

    for the main band.

    MAIN

    T X

    MAIN

    T X

    MAIN

    T X

    MAIN

    T X

    [EXAMPLE]: Setting frequency to 145.3625 MHz.

    Push

    Push

    Push

    Push

    Rotate the desired [DIAL].

    MAIN

    T X

    MAIN

    T X

    M M

    Frequency band initial is displayed.

    Push the desired bands[MAINBAND] for 1 sec.

    [DIAL]

  • 8/8/2019 Icom IC-2720H Instruction Manual

    15/96

    X

    QUICK REFERENCE GUIDE

    I Repeater operation1. Setting duplex

    Push desired bands [MAINBAND] to select the main band.Push [DUPMONI] once or twice to select minus duplex orplus duplex. The USA version has an auto repeater function, therefore, setting

    duplex is not required.

    2. Repeater tone

    Push [TONEDTMF] several times until T appears, if the re-peater requires a subaudible tone to be accessed.

    Using the HM-133Plus or minus duplex selection and the repeater tone setting

    can be made easily via HM-133.

    Push [DUP 7(TONE)] for minus duplex; [DUP+ 8(TSQLS)]

    for plus duplex selection, push [FUNC] then [DUP 7(TONE)]

    to turn the repeater tone ON.MAIN

    T X

    DUP

    MAIN

    T X

    DUP

    MAIN

    T X

    T

    Push

    Push , then

    Push

    MAIN

    T X

    DUP T

    Push [TONEDTMF].

    MAIN

    T X

    DUP

    Push [DUPMONI].

    Quickreferenceguid

    e

  • 8/8/2019 Icom IC-2720H Instruction Manual

    16/96

    XI

    QUICK REFERENCE GUIDE

    I Programming memory channelsThe IC-2720H has a total of 212 memory channels (including10 scan edges and 2 call channels) for storing often used op-

    erating frequency, repeater settings, etc.

    Any memory channel can be recalled from either left or right

    band.

    1. Setting a frequencyIn VFO mode, set the desired operating frequency with re-

    peater, tone and tuning steps, etc.

    Push the desired bands [V/MHzSCAN] to select VFO. Rotate the same bands [DIAL] to set the desired frequency.

    Set other data, such as repeater tone, duplex information, tuning

    step), if desired.

    2. Selecting a memory channel

    Push the same bands [M/CALLMW] for 1 sec., then rotatethe [DIAL] to select the desired memory channel. ! indicator and memory channel number blink.

    3. Writing a memory channel

    Push and hold the [M/CALLMW] for 1 sec. to program. 3 beeps sound

    Return to VFO mode automatically after the program.

    Memory channel number automatically increases when continuing

    to push the [M/CALLMW] after programming.

    MAINT X

    M

    Push [M/CALLMW] for 1 sec.

  • 8/8/2019 Icom IC-2720H Instruction Manual

    17/96

    XII

    QUICK REFERENCE GUIDE

    Using the HM-133q In VFO mode, set the desired operating frequency, includ-

    ing offset direction, tone settings, etc.

    Push [VFO/LOCK] to select VFO. Push [ENT C(T-OFF)] first, then enter the desired oper-

    ating frequency via the keypad. Set other data, such as repeater tone, duplex information,tuning step, if necessary.

    w Push [FUNC] then [CLR A(MW)]. ! indicator and memory channel number blink.

    e Push [Y]/[Z] to select the desired memory channel.

    r Push [FUNC] then push [CLR A(MW)] for 1 sec. to pro-

    gram. 3 beeps sound

    Memory channel number automatically increases when continu-

    ing to push [CLR A(MW)] after programming.

    MAIN

    T X

    M

    Push ,then

    Quickreferenceguid

    e

    1

  • 8/8/2019 Icom IC-2720H Instruction Manual

    18/96

    I Front panel controller

    qPOWER SWITCH [PWR]

    Turns power ON and OFF when pushed for 1 sec.

    wSETLOCK SWITCH [SET ]

    Enters set mode when pushed. (p. 56)

    Switches the lock function ON and OFF when pushedfor 1 sec. (p. 15)

    eOUTPUT POWERPRIORITY SWITCH [LOWPRIO]

    Each push changes the output power selection. (p. 20) Starts priority watch when pushed for 1 sec. (p. 47)

    rTONEDTMF SWITCH [TONEDTMF]

    Each push selects a tone function. (pgs. 23, 52) Subaudible tone encoder, pocket beep (CTCSS), tone

    squelch, pocket beep (DTCS), DTCS squelch or tone func-

    tion OFF can be selected.

    Turns DTMF memory encoder ON and OFF whenpushed for 1 sec. (p. 48)

    tDUPLEXMONITOR SWITCH [DUPMONI]

    Push to select DUP, DUP+ and simplex operation.(p. 23)

    Push for 1 sec. to switch the monitor function ON and

    OFF. (p. 16)

    MAINBAND

    SCAN

    MW

    V/MHz

    M/CALL

    MAINBAND

    SCANV/MHz

    MWM/CALL

    VOLVOL

    DIALDIAL

    SQLSQL

    DUP

    MONI

    TONE

    DTMF

    LOW

    PRIO

    DUAL BAND FM TRANSCEIVER i2720

    PWR SET

    BUSY LOWMIDBUSY LOWMID

    MAIN

    T X

    DUP T SQL DTCSAM

    MAIN

    T X

    DUP T SQL DTCSAM

    MSKIP

    MSKIP

    q Function display (pgs. 3, 4) w

    ert

    1

    PANEL DESCRIPTION1

    *The switches w to t are

    for the MAIN band only.

  • 8/8/2019 Icom IC-2720H Instruction Manual

    19/96

    2

    1PANEL DESCRIPTION

    1

    yMAINBAND SWITCH [MAINBAND]

    Push to select the main band. (p. 11) Enters operating band select condition when pushed for

    1 sec. (p. 11)

    uVFO/MHz TUNINGSCAN SWITCH [V/MHzSCAN]

    Selects and toggles VFO mode and 1 MHz (or 10 MHz

    for some versions) tuning when pushed. (p. 12) Starts scan when pushed for 1 sec. (p. 41)

    Cancels a scan when pushed during scan.

    iMEMORY/CALLMEMORY WRITE SWITCH [M/CALLMW] Push to select and toggle memory, call and weather

    channel* modes. (pgs. 12, 29, 38, 65)

    *Weather channels available for USA versions only. Selects a memory channel for programming whenpushed for 1 sec. (pgs. 30, 39, 42)

    oVOLUME CONTROL [VOL] (p. 16)

    Adjusts the audio level for relative band.

    !0TUNING DIAL [DIAL]

    Selects the operating frequency (p. 13), memory channel

    (p. 29), the setting of the set mode item and the scanning

    direction (p. 41) for the relative band.

    !1SQUELCH CONTROL [SQL]

    Varies the squelch level for relative band. (p. 16) The RF attenuator activates and increases the attenuation when

    rotated clockwise to the center position and further. (p. 17)

    MAINBAND

    SCAN

    MW

    V/MHz

    M/CALL

    MAINBAND

    SCANV/MHz

    MWM/CALL

    VOLVOL

    DIALDIAL

    SQLSQL

    DUP

    MONI

    TONE

    DTMF

    LOW

    PRIO

    DUAL BAND FM TRANSCEIVER i2720

    PWR SET

    o o

    Left band Right band

    y

    u

    i

    !0

    y

    u

    i

    !0

    !1!1*The same controls for both the left and

    right bands are arranged in symmetry.

  • 8/8/2019 Icom IC-2720H Instruction Manual

    20/96

    3

    1 PANEL DESCRIPTION

    I Function display

    qMAIN INDICATOR (p. 11)

    Indicate the main band for transmit and function control.

    wTRANSMIT INDICATOR Appears while transmitting. (p. 20)

    Blinks while transmitting with the one-touch PTT func-

    tion. (p. 21)

    eDUPLEX INDICATORS (p. 23)

    DUP appears when plus duplex, DUP appears whenminus duplex (repeater) operation is selected.

    rTONE INDICATORS

    T appears while the subaudible tone encoder is in use.(p. 23)

    T SQL appears while the tone squelch function is inuse. (p. 52)

    DTCS appears while the DTCS squelch function is inuse. (p. 52)

    S appears with the T SQL or DTCS indicatorwhile the pocket beep function (with CTCSS or DTCS) is in

    use. (p. 52)

    BUSY LOWMIDBUSY LOWMID

    MAIN

    T X

    DUP T SQL DTCS

    AM

    MAIN

    T X

    DUP T SQL DTCS

    AM

    MSKIP

    MSKIP

    q w e r t

    y

    uio!0!1!2

    y

    q w e r t

    uio!0!1!2

    Left band Right band

    *The same indications for both the left and right bands are arranged.

  • 8/8/2019 Icom IC-2720H Instruction Manual

    21/96

    4

    1PANEL DESCRIPTION

    1tAM INDICATOR (p. 64)

    Appears when AM mode is selected.

    yFREQUENCY READOUT

    Shows the operating frequency, set mode contents, etc. Frequency decimal point blinks while scanning. (p. 41)

    d appears in place of the 1st digit while the DTMF memory

    function is in use. (p. 48)

    uMEMORY CHANNEL NUMBER INDICATORS

    Shows the selected memory channel number. (p. 29)

    Shows the selected bank initial. (p. 35) C appears when the call channel is selected. (p. 38) L appears when the lock function is activated. (p. 15)

    iSKIP INDICATOR (p. 44)

    Appears when the displayed memory channel is specifiedas a skip channel.

    oMEMORY INDICATOR (pgs. 12, 29)

    Appears when memory mode is selected.

    !0S/RF INDICATORS

    Shows the relative signal strength while receiving sig-

    nals. (p. 16) Shows the output power level while transmitting. (p. 20)

    !1OUTPUT POWER INDICATORS

    LOW appears when low output power; MID appearswhen middle output power is selected.

    No indicator appears when high output power is selected.

    !2BUSY INDICATOR

    Appears when a signal is being received or the squelch

    is open. (p. 16) Blinks while the monitor function is activated. (p. 16)

  • 8/8/2019 Icom IC-2720H Instruction Manual

    22/96

    5

    1 PANEL DESCRIPTION

    I Main unit

    qDATA SOCKET [DATA]

    Connects a TNC (Terminal Node Controller), etc. for data

    communications. See p. 6 for connection information.

    wMICROPHONE CONNECTOR [MIC]

    Connects the supplied or an optional microphone.

    q +8 V DC output (Max. 10 mA)

    w Channel up/downe 8 V control IN

    r PTT

    t GND (microphone ground)

    yMIC (microphone input)

    u GND

    i Data IN

    e CONTROLLER CONNECTOR [CONTROLLER] (p. V)

    Connects the controller unit with the supplied cable.

    rCOOLING FANRotates while transmitting.

    Also rotates while receiving depending on the setting in ini-

    tial set mode. (p. 62)

    tANTENNA CONNECTOR [ANT]

    Connects a 50 antenna with a PL-259 connector and a

    50 coaxial cable.

    ANTENNA INFORMATION

    For radio communications, the antenna is of critical impor-

    tance, to maximize your output power and receiver sensi-

    tivity. The transceiver accepts a 50 antenna and less

    than 1:1.5 of Voltage Standing Wave Ratio (VSWR). High

    SWR values not only may damage the transceiver but alsolead to TVI or BCI problems.

    qi

    q w e

    r t y u

    i

  • 8/8/2019 Icom IC-2720H Instruction Manual

    23/96

    6

    1PANEL DESCRIPTION

    1yEXTERNAL SPEAKER JACK 1 [SP-1]

    Connects an 8 speaker. Outputs both left and right

    bands audio when no external speaker is connected to

    [SP-2]. See the table below for details. Audio output power is more than 2.4 W.

    uEXTERNAL SPEAKER JACK 2 [SP-2]

    Connects an 8 speaker. Outputs right bands audio only. Audio output power is more than 2.4 W.

    iPOWER RECEPTACLE [DC13.8V]

    Accepts 13.8 V DC 15% with the supplied DC power

    cable.

    NOTE: DO NOT use a cigarette lighter socket as a

    power source when operating in a vehicle. The plugmay cause voltage drops and ignition noise may be su-

    perimposed onto transmit or receive audio.

    D Speaker information

    DDATA JACK PIN ASSIGNMENT

    qDATA IN

    Input terminal for data transmit. See p. 62 for details on

    how to toggle data speed between 1200 (AFSK) and

    9600 bps (G3RUH, GMSK).

    wGND

    Common ground for DATA IN, DATA OUT and AF OUT.ePTT P

    PTT terminal for packet operation only. Connect ground to

    transmit data.rDATA OUT

    Data out terminal for 9600 bps operation only.

    tAF OUT

    Data out terminal for 1200 bps operation only.yP SQL

    Becomes high (+5 V) when the transceiver receives a sig-

    nal which opens the squelch.

    To avoid unnecessary TNC transmission, connect squelch to the

    TNC to inhibit transmission when receiving signals.

    Keep audio output at a normal level, otherwise a P SQL signal

    will not be output.

    Front panel view

    w

    y

    r

    q

    e

    t

    ConnectedLeft band audio Right band audio

    speaker

    No external Internal speaker (mixed audio)speakers

    [SP-1] only External speaker (mixed audio)

    [SP-2] only Internal speaker External speaker

    2 external External speaker via External speaker via

    speakers [SP-1] [SP-2]

  • 8/8/2019 Icom IC-2720H Instruction Manual

    24/96

    7

    1 PANEL DESCRIPTION

    I Microphone (HM-133*)

    qVFO/LOCK SWITCH [VFO/LOCK]

    Push to select VFO mode. (p. 12) Push for 1 sec. to switch the lock function ON and OFF.

    (p. 15)wPTT SWITCH

    Push and hold to transmit; release to receive. Switches between transmitting and receiving while the

    one-touch PTT function is in use. (p. 21)

    eUP/DOWN SWITCHES [Y]/[Z]

    Push either switch to change operating frequency,

    memory channel, set mode setting, etc. (pgs. 13, 29, 56) Push either switch for 1 sec. to start scanning. (p. 41)

    rACTIVITY INDICATOR

    Lights red while any key, except [FUNC] and [DTMF-S],is pushed, or while transmitting.

    Lights green while the one-touch PTT function is in use.

    tKEYPAD (pgs. 8, 9)

    yFUNCTION INDICATOR

    Lights orange while [FUNC] is activatedindicates the

    secondary function of switches can be accessed. Lights green when [DTMF-S] is activatedDTMF sig-

    nals can be transmitted with the keypad.

    u2nd FUNCTION SWITCH [FUNC]

    iDTMF SELECT SWITCH [DTMF-S] (p. 50)

    oFUNCTION SWITCHES [F-1]/[F-2] (p. 66)

    Program and recall your desired transceiver conditions.

    !0BAND SWITCH [BAND] (p. 11)

    Push to switches main band between left and right bands.

    !1MEMORY/CALL SWITCH [MR/CALL]

    Push to select memory mode. (p. 12) Push for 1 sec. to select call channel. (p. 38)

    Important!

    All keys on the microphone function for the main band only.

    Mic element

    q

    e

    r

    t

    w

    yui

    o

    !0!1

    *A different microphonemay be supplied de-

    pending on version.

  • 8/8/2019 Icom IC-2720H Instruction Manual

    25/96

    8

    1PANEL DESCRIPTION

    1I Microphone keypadKEY FUNCTION SECONDARY FUNCTION ( +key) OTHER FUNCTIONS

    Switches between opening and closing the

    squelch. (p. 16)

    Starts and stops scanning. (p. 41)

    Starts and stops priority watch. (p. 47)

    Selects high output power. (p. 20)

    Selects mid. output power. (p. 20)

    Selects low output power (p. 20)

    Selects minus duplex operation. (p. 24)

    Selects plus duplex operation. (p. 24)

    Selects simplex operation. (p. 24)

    Increases audio output level. (p. 16)

    In VFO mode enters operating band select-

    ing condition. (p. 12)

    In memory mode enters bank selecting

    condition. (p. 35)Starts and stops tone scanning. (p. 55)

    Turns the one-touch PTT function ON and

    OFF. (p. 21)

    Turns the DTCS squelch ON. (p. 53)

    Turns the DTCS pocket beep function ON.

    (p. 53)

    Turns the DTMF memory encoder function

    ON. (p. 49)

    Turns the subaudible tone encoder ON.

    (p. 24)

    Turns the CTCSS pocket beep function

    ON. (p. 53)

    Turns the tone squelch function ON.

    (p. 53)

    Sends a 1750 Hz tone signal while pushing

    and holding. (p. 26)

    After pushing :

    Transmits the appropriate

    DTMF code. (pgs. 26, 50)

    When the DTMF memory en-

    coder is activated, push [0] to

    [9] to transmit the appropriate

    DTMF memory contents .

    (p. 50)

  • 8/8/2019 Icom IC-2720H Instruction Manual

    26/96

    9

    1 PANEL DESCRIPTION

    Cancels frequency entry. (p. 13)

    Cancels the scan or priority watch.

    (pgs. 41, 47)

    Exit set mode. (p. 56)

    Enters set mode (p. 56)

    Advances the set mode selection order

    after entering set mode. (p. 56)

    Sets the keypad for numeral input.

    (p. 13) Reverses the set mode selection order

    after entering set mode. (p. 56)

    Adjusts the squelch level increments.

    (p. 16)

    Decreases audio output level. (p. 16)

    Adjusts the squelch level decrement.

    (p. 16)

    Selects a memory channel for program-

    ming. (p. 31)

    Advances the memory channel number

    when continuously pushed after pro-gramming is completed. (p. 31)

    DTMF memory encoder function OFF.

    (p. 50)

    Turns the subaudible tone encoder, pocket

    beep or CTCSS/DTCS tone squelch OFF.(pgs. 24, 53)

    Mutes the audio. (p. 21)

    Mute function is released when any oper-

    ation is performed.

    Sends a 1750 Hz tone signal for 0.5 sec.(p. 26)

    Locks the digit keys on the keypad (includ-

    ing the A to D, # andM keys. (p. 15)

    After pushing :

    Transmits the appropriateDTMF code. (pgs. 26, 50)

    KEY FUNCTION SECONDARY FUNCTION ( +key) OTHER FUNCTIONS

    1

  • 8/8/2019 Icom IC-2720H Instruction Manual

    27/96

    10

    1PANEL DESCRIPTION

    1I Optional Microphones(HM-118N/TN/TAN)

    qPTT SWITCH

    Push and hold to transmit; release to receive.

    wUP/DOWN SWITCHES [UP]/[DN]

    Push either switch to change operating frequency,memory channel, set mode setting, etc. (pgs. 13, 29, 56)

    Push either switch for 1 sec. to start scanning. (p. 41)

    eUP/DN LOCK SWITCH

    Slide to toggle [UP]/[DN] switches function ON and OFF.

    rKEYPAD (HM-118TN/TAN only)

    While pushing [PTT], push the desired key to send theDTMF code.

    w

    q

    ON

    OFF

    e

    w

    r

    q

    ON

    OFF

    e

    HM-118N

    HM-118TN/TAN

    (DTMF)

    SETTING A FREQUENCY2

  • 8/8/2019 Icom IC-2720H Instruction Manual

    28/96

    11

    SETTING A FREQUENCY2

    I PreparationD Turning power ON/OFF

    Push [PWR] for 1 sec. to turn power ON and OFF.

    DMAIN bandThe IC-2720H can receive 144 MHz and 430(440) MHz band

    signals simultaneously. To activate all functions access or to

    change frequency via the microphone, you must designate

    one band as the main band. The transceiver transmits a sig-nal on the main band only.

    Push the desired bands [MAINBAND] to select the mainband. Q indicates the main band.

    Push [BAND] to toggle the main band between

    left and right bands.

    D Operating frequency band selection

    In the default condition, or after resetting the CPU, 2 m band

    is assigned in the left band, 70 cm band is assigned in the

    right band. However, the 2 m band can also be assigned into

    the right, and 70 cm band can also be assigned into the left

    band.

    qPush the desired bands [MAINBAND] for 1 sec. Frequency band initial appears.

    wRotate the same bands [DIAL] to select the desired fre-

    quency band. Pushing [Y]/[Z] on the microphone also selects the band.

    ePush the [MAINBAND] to return to frequency indication inthe selected frequency band.

    MAIN

    T X

    MAIN

    T X

    M M

    Frequency band initial is displayed.

    Push the desired bands[MAINBAND] for 1 sec.

    [DIAL]

    BAND

    Push the desired bands[MAINBAND]

    Push [PWR] for 1 sec.

    Note that in this manual, sections beginning with a micro-

    phone icon (as at left), designate operation via the HM-133microphone.

    2

  • 8/8/2019 Icom IC-2720H Instruction Manual

    29/96

    12

    2SETTING A FREQUENCY

    2z Push [BAND] to select main band.x Push [FUNC], the push [BANK 1(MONI)] to se-

    lect frequency band selecting condition. The frequency band initial is displayed.

    c Push [Y]/[Z] to select the desired frequency

    band.

    v Push [CLR A(MW)] to exit the condition, and re-

    turn to frequency indication.

    About extra frequency bands

    USA and General versions only

    In addition to the 2 m and 70 cm ham bands, the IC-2720H

    USA and General versions have extra frequency bands for

    each left and right bands as follow.

    See the specifications for the available frequency bands fordetails.

    *The frequency band initials are default indication only. Once the op-

    erating frequency is set in the band, the initial indication will be

    changed. : Available, : Not available

    D VFO and memory modesThe transceiver has 2 basic operating modes: VFO mode and

    memory mode. Select VFO mode first to set an operating fre-quency.

    Push the desired bands [V/MHzSCAN] to select VFOmode. When VFO mode is already selected, the digit below 10 MHz

    (the digit below 1 MHz or 100 kHz disappear depending on ver-

    sions) disappear. In this case, push [V/MHzSCAN] again (or

    twice or 3 times depending on version). Push [M/CALLMW] to select memory mode.

    ! indicator appears when memory mode is selected.

    Push [VFO/LOCK] to select VFO mode.

    Push [MR/CALL] to select memory mode. The microphone controls the main band only. Push

    [BAND] to toggle the main band, then push[VFO/LOCK] or [MR/CALL], if necessary.

    VFO/LOCK

    MAIN

    T X

    MAIN

    T X

    M M

    Push [M/CALLMW]

    to select memory mode

    VFO mode is selected ! indicator appears whenmemory mode is selected

    Push [V/MHzSCAN]to select VFO mode

    BANK

    [Y]/[Z]

    FrequencyLeft band Right band

    band initial*

    127

    222

    375

    500

    900

    2 S G Q C

  • 8/8/2019 Icom IC-2720H Instruction Manual

    30/96

    13

    2 SETTING A FREQUENCY

    I Using the tuning dialqRotate the desired bands [DIAL] to set the frequency.

    If VFO mode is not selected, push the same band s

    [V/MHzSCAN] to select VFO mode.

    The frequency changes in the selected tuning steps. (p. 14)

    wTo change the frequency in 1 MHz (10 MHz for some versions)

    steps, push [V/MHzSCAN], then rotate [DIAL]. Pushing [V/MHzSCAN] for 1 sec. starts scan function. If scan

    starts, push [V/MHzSCAN] again to cancel it.

    I Using the [Y]/[Z] keys Push [Y] or [Z] to select the desired frequency.

    Push [BAND] to select the desired band (left or right)

    as the main band in advance.

    Pushing [Y]/[Z] for 1 sec. activates a scan. If scan

    starts, push [Y]/[Z] or [CLR A(MW)] to cancel it.

    I Using the keypadThe frequency can be directly set via numeral keys on the mi-crophone.

    z Push [BAND] to select the desired band (left or

    right) as the main band. Push [VFO/LOCK] to select VFO mode, if necessary.

    xPush [

    ENT

    C(T-OFF)] to activate the keypad fordigit input.

    c Push 6 keys to input a frequency. When a digit is mistakenly input, push [ENT C(T-OFF)]

    to clear the input, then repeat input from the 1st digit.

    Pushing [CLR A(MW)] clears input digits and retrieves

    the frequency.

    MAIN

    T X

    MAIN

    MAIN

    T X

    MAIN

    T X

    Push

    Push

    Push

    Push

    [EXAMPLE]: Setting frequency to 145.3625 MHz.

    ENTC

    YZ

    MAIN

    T X

    MAIN

    T X

    M M

    While 1 MHz tuning step isselected, the digit below

    100 kHz disappear.

    While 10 MHz tuning stepis selected, the digit below

    1 MHz disappear.

    Push [V/MHzSCAN]

    Rotate the tuning dial

    2SETTING A FREQUENCY

  • 8/8/2019 Icom IC-2720H Instruction Manual

    31/96

    14

    2SETTING A FREQUENCY

    2I Tuning step selection[Tuning steps are the minimum frequency change increments

    when you rotate [DIAL] or push [Y]/[Z] on the microphone.

    Independent tuning step for the left and right, as well as each

    frequency bands can be set for individual tuning convenience.

    The following tuning steps are available.

    5 kHz 10 kHz 12.5 kHz 15 kHz 20 kHz 25 kHz 30 kHz 50 kHz

    NOTE: For convenience, select a tuning step that matches

    the frequency intervals of repeaters in your area.

    q Push the desired bands [MAINBAND] to select the mainband. Push the same bands [V/MHzSCAN] to select VFO mode, if

    necessary.

    wPush [SET ] to enter set mode.

    ePush [SET ] or [LOWPRIO] several times until tS ap-pears as shown below.

    rRotate the same bands [DIAL] to select the desired tuningstep.

    tPush [TONEDTMF] to exit set mode.

    z Push [BAND] to select the desired band (left orright) as the main band. Push [VFO/LOCK] to VFO mode, if necessary.

    x Push [SET B(D-OFF)] to enter set mode.

    c Push [SET B(D-OFF)] or [ENT C(T-OFF)] several

    times until tS appears.v Push [Y] or [Z] to select the desired tuning step.

    b Push [CLR A(MW)] to exit set mode.

    SETB

    MAIN

    T X

    Push [SET ]

    [LOWPRIO]

    2 SETTING A FREQUENCY

  • 8/8/2019 Icom IC-2720H Instruction Manual

    32/96

    15

    2 SETTING A FREQUENCY

    ILock functionsTo prevent accidental frequency changes and unnecessary

    function access, use the lock function. The transceiver has 2

    different lock functions.

    D Frequency lockThis function locks [DIAL] and switches electronically and can

    be used together with the microphone lock function.

    Push [SET ] for 1 sec. to turn the lock function ON and

    OFF. [PTT], [DUPMONI] (monitor function only), [VOL], [SQL] and

    [MAINBAND] (main band selection only) can be used while the

    channel lock function is in use. Also, TONE-1, TONE-2, DTMF

    tones or DTMF memory contents can be transmitted from the mi-

    crophone.

    Push [VFO/LOCK] for 1 sec. to switch the

    lock function ON and OFF.

    DMicrophone keypad lockThis function locks the microphone keypad.

    Push [FUNC] then [SQLZ D(16KEY-L)] to

    switch the microphone keypad lock function

    ON and OFF.

    [PTT], [VFO/LOCK], [MR/CALL], [BAND], [Y], [Z],[F-1], [F-2], [DTMF-S] and [FUNC] on the micro-

    phone can be used.

    All switches on the transceiver can be used.

    The keypad lock function is released when the

    power is turned OFF then ON again.

    16KEY-L

    VFO/LOCK

    MAINT X

    MAINT X

    M M

    Push [SET ]for 1 sec.

    2 Ls appear while the lock function is activated.

    3BASIC OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    33/96

    16

    3BASIC OPERATION

    2

    3

    IReceivingqSet the audio level for the main band.

    Push the desired bands [MAINBAND]. Push [DUPMONI] for 1 sec. to open the squelch. Rotate the main bands [VOL] to adjust the audio level. Push the [DUPMONI] for 1 sec. to close the squelch.

    wSet the squelch level.

    Rotate the main bands [SQL] fully counterclockwise inadvance, then rotate the [SQL] clockwise until the noise

    just disappears. When interference is received, rotate the [SQL] clockwise

    again for attenuator operation. (p. 17)

    eSet the operating frequency in the main band. (pgs. 1113)rWhen receiving a signal on the set frequency, squelch

    opens and the transceiver emits audio. BUSY appears and the S/RF

    indicator shows the relative

    signal strength for the re-

    ceived signal.

    CONVENIENT!

    The main bands audio and squelch level can alsobe adjusted with [VOLY(TONE-1)]/[VOLZ 0(TONE-2)]

    and [SQLY D(MUTE)]/[SQLZ #(16KEY-L)], respectively. VOL for audio or SqL for squelch appears during set.

    IMonitor functionThis function is used to listen to weak signals without disturb-

    ing the squelch setting.

    Push [DUPMONI] for 1 sec. to open the squelch. Push [MINBAND] to select the desired band (left or right) as the

    main band in advance.

    BUSY blinks.

    Push [DUPMONI] for 1 sec. again to cancel the function.

    Push [MONI 1(BANK)] to open the squelch. Push [BAND] to select the desired band (left or right)

    as the main band in advance.

    Push [MONI 1(BANK)] again to cancel the function.

    NOTE: When the [SQL] adjustment is set too far clock-

    wise, (125 oclock position) the squelch attenuator is acti-vated. To monitor weak signals on the operating frequency,

    deactivate the squelch attenuator function. See pg. 17 for

    details.

    MONI1

    BUSY

    MAIN

    T X

    MAIN

    T X

    M M

    Push [DUPMONI]for 1 sec.

    M

    Show set level.

    SQLY/Z

    D/#

    VOLY/Z

    M/0

    BUSY

    MAIN

    T X

    M

    Appears when receiving a signal.

    3 BASIC OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    34/96

    17

    3 BASIC OPERATION

    ISquelch attenuatorThe transceiver has an RF attenuator related to the squelch

    level setting. Approx. 10 dB attenuation is obtained at maxi-

    mum setting.

    The squelch attenuator allows you to set a minimum signal

    level needed to open the squelch. The attenuator function can

    be deactivated in initial set mode.

    Rotate [SQL] clockwise past the 12 oclock position to ac-tivate the squelch attenuator. Attenuation level can be adjusted up to 10 dB (approx.) between

    12 oclock and fully clockwise position.

    When setting the squelch from the microphone, a level greater

    than 19 activates the squelch attenuator.

    NOTE: The squelch attenuator functions even when the

    monitor function is in use. Thus set the [SQL] control within

    10 to 12 oclock position is recommended when using the

    monitor function.

    D Squelch attenuator settingqTurn the transceiver power OFF.

    wWhile pushing [SET ], turn the power ON to enter initial

    set mode.

    ePush [SET ] or [LOWPRIO] to select Att-On (squelch

    attenuator) item.

    rRotate the left bands [DIAL] to toggle the function ON and

    OFF. Select OF to deactivate the squelch attenuator function.

    tPush [PWR] to exit initial set mode.

    MAIN

    T X

    M

    MAIN

    T X

    M

    While pushing [SET ]push [PWR] to enter initial

    set mode

    USING INITIAL SET MODE

    Squelch isopen.

    Squelchattenuator

    Squelchthreshold

    Shallow Deep

    Noise squelch

    3BASIC OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    35/96

    IV/V, U/U simultaneous receive (Para-watch)

    18

    3BASIC OPERATION

    3

    The IC-2720H can simultaneously receive two signals on the

    same band, such as 144 MHz band, using the para-watch

    function.

    qPush either the left or right bands [MAINBAND] for 1 sec.to select the frequency band selecting condition.

    wRotate the same bands [DIAL] to select the desired fre-quency band.

    ePush the [MAINBAND] to return to frequency indication.rSet the desired frequency.

    tRepeat the stepsq tor for the other band (left or right).

    To activate the para-watch function from the HM-133, enter

    the desired frequencies for each the left and right bands using

    the direct frequency input capability via the keypad; or per-

    form the following operation.

    z Push [FUNC], the push [BANK 1(MONI)] to se-lect frequency band selecting condition. The frequency band initial appears on the main band.

    x Push [Y]/[Z] to select the desired frequency

    band band.c Push [CLR A(MW)] to exit the condition, and re-

    turn to frequency indication.

    v Push [VFO/LOCK] to change main band, thenrepeat the stepsz toc for the other band.

    NOTE:

    Memory channels are common for the left and right band. Transmitting during the para-watch operation is possible.

    However, the sub bands reception is deactivated during

    transmit as shown in the example at left.

    BANK

    [Y]/[Z]

    MAIN

    T X

    MAIN

    T X

    M M

    MAIN

    T X

    DUP MAIN

    T X

    M M

    MAIN

    T X

    MAIN

    T X

    M M

    [Example]

    While transmitting on the main band, the sub bands memory channelreadout shows the current condition and Si indication alternately.

    Can be switchedbetween VHF andUHF

    3 BASIC OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    36/96

    The sub band mute function automatically cuts out sub band

    audio signals when both main and sub band signals are re-

    ceived simultaneously.

    While operating on the main band, a beep sounds to inform

    you that a signal was received on the sub band.

    qWhile pushing [SET ], push [PWR] for 1 sec. to enter

    initial set mode.

    wPush [SET ] or [LOWPRIO] until SUb appears in thedisplay as shown above.

    eRotate the left bands [DIAL] to select the condition.

    rPush [PWR] momentarily, to exit initial set mode and return

    to the previous indications.

    While pushing [SET ]push [PWR] to enter initialset mode

    MAIN

    T X

    M

    The display shows thatthe sub band mute isturned ON and sub bandbusy beep is turned ON.

    19

    3 BASIC OPERATION

    ISub band mute/sub band busy beep

    USING INITIAL SET MODE

    DISPLAY SUB BAND MUTE BUSY BEEP

    SUb-OF OFF OFF

    SUb-OFS OFF ON

    SUb-On ON OFF

    SUb-OnS ON ON

    3BASIC OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    37/96

    20

    3BASIC OPERATION

    3

    ITransmitting

    NOTE: To prevent interference, listen on the channel be-

    fore transmitting by pushing [DUPMONI] for 1 sec., or[MONI 1(BANK)] on the microphone.

    qSelect the main band. (p. 11)

    wSet the operating frequency. (pgs. 1113) Select output power if desired. See section at right for details.

    ePush and hold [PTT] to transmit. $ appears.

    The S/RF indicator shows the output power selection.

    A one-touch PTT function is available. See p. 21 for details. Si may blinks instead of the sub bands memory channel num-

    ber indication according to the selected frequency band.

    rSpeak into the microphone using your normal voice level. DO NOT hold the microphone too close to your mouth or speak

    too loudly. This may distort the signal.

    tRelease [PTT] to return to receive.

    ISelecting output powerThe transceiver has 3 output power levels to suit your oper-

    ating requirements. Low output powers during short-distance

    communications may reduce the possibility of interference to

    other stations and will reduce current consumption.

    Push [LOWPRIO] once or twice to select the outputpower.

    *approx.

    The output power can be changed while transmitting.

    The microphone can also be used to select output power.

    Push [HIGH 4(DTCS)] for high output power;

    [MID 5(DTCSS)] for middle output power; and

    [LOW 6(DTMF)] for low output power. The output power can be changed via the microphone

    during receive only.

    HIGH

    4

    MID5

    LOW6

    IMPORTANT!(for 50/35 W transmission):

    The IC-2720H is equipped with protection circuit to protect

    the power amplifier circuit from high SWR (Standing Wave

    Ratio) and temperature. When a high SWR antenna or no

    antenna is connected, or when the transceiver temperature

    becomes extremely high, the transceiver reduces transmitoutput power to 15 W (approx.) automatically.

    CAUTION: Transmitting without an antenna will damage

    the transceiver.

    S/RF INDICATORPOWER OUTPUT

    VHF/UHF Taiwan

    50 W/35 W 25 W

    15 W*/15 W* 15 W*

    5 W*/5 W* 5 W*

    High:

    Mid:

    Low:

    3 BASIC OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    38/96

    21

    IOne-touch PTT functionThe PTT switch can be operated as a one-touch PTT switch

    (each push toggles between transmit/receive). Using this

    function you can transmit without pushing and holding the

    PTT switch.

    To prevent accidental, continuous transmissions with this

    function, the transceiver has a time-out timer. See p. 61 fordetails.

    z Push [FUNC] then [PRIO 3(PTT-M)] to turn the

    one-touch PTT function ON.

    The activity indicator lights green.

    x Push [PTT] to transmit and push again to re-

    ceive. A beep sounds when transmission is started and a

    long beep sounds when returning to receive.

    $ blinks when transmitting with the one-touch

    PTT function.

    c Push [FUNC] then [PRIO 3(PTT-M)] to turn the

    one-touch PTT function OFF.

    The activity indicator goes out.

    IAudio mute functionThis function temporarily mutes the audio without disturbing

    the volume setting.

    Push [FUNC] then [SQLY D(MUTE)] to mute

    audio signals. The memory channel number indicator shows the

    current condition and Si indications alternately. Push [CLR A(MW)] (or any other key) to cancel the

    function.

    BUSY

    MAIN

    T X

    MAIN

    T X

    M M

    Shows the current condition and Si indication alternately.

    MUTE

    MAIN

    T X

    T X

    M

    indicator blinks

    PTT-M

    4REPEATER OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    39/96

    22

    3

    4

    IGeneral

    Repeaters allow you to extend the operational range of your

    radio because a repeater has much higher output power than

    the typical transceiver.

    Normally, a repeater has indipendent frequencies for each re-

    ceiver and transmitter.A subaudible tone may also be required to access a repeater

    Reference amateur radio hand books and local ham maga-

    zines for details of local repeaters such as repeater input/out-

    put frequencies and locations.

    Repeater operation flow chart

    The IC-2720H USA version has the auto repeater function. Thus the

    steps 3 and 4 may not be necessary, depending on the setting. Repeater settings can be stored into a memory channel.

    Step 3:

    Set the duplex (shifting) direction ( duplex or +duplex).- Set the offset frequency (shifting value), if required.

    Step 4:Set the subaudible tone (repeater tone) encoder function ON.- Set the subaudible tone frequency, if required.

    Step 1:

    Set the desired band to operate the repeater.

    Step 2:

    Set the desired receive frequency (repeater output frequency).

    Repeater example;

    Receives the 444.540 MHz signaland the detected audio signals aretransmitted on 449.540 MHz simul-taneously.

    Station A:Tx: 444.540 MHzRx: 449.540 MHz

    Station B:Tx: 444.540 MHzRx: 449.540 MHz

    4 REPEATER OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    40/96

    IAccessing a repeaterq Set the receive frequency (repeater output frequency) on

    the main band. (pgs. 1113)w Push [DUPMONI] one or two times, to select minus du-

    plex or plus duplex. DUP or DUP appears to indicate the transmit frequency for

    minus shift or plus shift, respectively.

    When the auto repeater function is turned ON (available for theUSA version only), stepsw ande are not necessary. (p. 28)

    e Push [TONEDTMF] several times to turn ON the subaudi-ble tone encoder, according to repeater requirements. T appears

    88.5 Hz is set as the default; refer to p. 25 for tone frequency set-

    tings.

    When the repeater requires a different tone system, see p. 26.

    r Push and hold [PTT] to transmit. The displayed frequency automatically changes to the transmit

    frequency (repeater input frequency).

    If OFF appears, confirm that the offset frequency (p. 27) is set

    correctly.

    t Release [PTT] to receive.

    yPush [DUPMONI] to check whether the other stations

    transmit signal can be received directly.uTo return to simplex operation, push [DUPMONI] once or

    twice, to clear the DUP or DUP indicator.iTo turn OFF the subaudible tone encoder, push

    [TONEDTMF] several times until no tone indicators ap-pear.

    MAIN

    T X

    DUP T

    M

    MAIN

    T X

    DUP T

    M

    While receiving While transmitting

    MAIN

    T X

    DUP T

    M

    Push [TONEDTMF] once or twiceT appears

    MAIN

    T X

    DUP

    M

    Push [DUPMONI] once or twiceDUP or DUP appear

    23

    4REPEATER OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    41/96

    24

    4

    z Set the receive frequency (repeater output fre-

    quency) on the main band. (pgs. 1113)x Push [DUP 7(TONE)] to select minus duplex;

    push [DUP+ 8(TSQLS)] to select plus duplex.

    c Push [FUNC] then [DUP 7(TONE)] to turn ONthe subaudible tone encoder according to re-

    peater requirements. Refer to p. 25 for the tone frequency setting.

    When the repeater requires a different tone system,

    see p. 26.

    v Push and hold [PTT] to transmit.

    b Release [PTT] to receive.

    n Push [MONI 1(BANK)] to check whether the

    other stations transmit signal can be receiveddirectly.

    m Push [SIMP 9(TSQL)] to return to simplex opera-

    tion. DUP or DUP indicator disappears.

    , To turn OFF the subaudible tone encoder, push

    [FUNC] then [ENT C(T-OFF)].

    SIMP9

    MAIN

    T X

    DUP TPush ,

    then .

    MAIN

    T X

    DUP

    MAIN

    T X

    DUP

    Push

    Push

    DUP7

    DUP+8

    4 REPEATER OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    42/96

    I Subaudible tones(Encoder function)

    D Subaudible tonesq Select the main band, mode/channel you wish to set the

    subaudible tones to, such as VFO mode or memory/call

    channel.

    wPush [SET ] to enter set mode.e Push [SET ] or [DUPMONI] several times until T andrt appear; or until T SQL and Ct appear for tonesquelch or pocket beep use. When d is displayed in place of the 100 MHz digit, cancel the

    DTMF memory encoder in advance. (p. 50)

    r Rotate the main bands [DIAL] to select and set the desiredsubaudible frequency.

    t Push [TONEDTMF] to exit set mode.

    NOTE: The subaudible tone encoder frequency can be set

    in a memory/call channel temporarily. However, the set fre-

    quency is cleared once another memory channel or VFO

    mode is selected. To store the tone frequency permanently,

    overwrite the channel information.

    z Set the main band, mode/channel you wish to

    set the subaudible tones to, such as VFO modeor memory/call channel. The subaudible tone frequency is independently pro-

    grammed into each mode or channel.

    x Push [SET B(D-OFF)] to enter set mode.c Push [SET B(D-OFF)] or [ENT C(T-OFF)] several

    times until T and rt appears; or until T SQL

    and Ct appears for tone squelch or pocketbeep use. When d is displayed in place of the 100 MHz digit,

    cancel the DTMF memory encoder in advance. (p. 50)

    v Push [Y] or [Z] to select and set the desired

    subaudible tone frequency. Push and hold [Y]/[Z] to change the above tones

    continuously.b Push [CLR A(MW)] to exit set mode.

    Subaudible tone frequency list (unit: Hz)

    67.0

    69.3

    71.9

    74.4

    77.0

    79.7

    82.5

    85.4

    88.5

    91.5

    94.8

    97.4

    100.0

    103.5

    107.2

    110.9

    114.8

    118.8

    123.0

    127.3

    131.8

    136.5

    141.3

    146.2

    151.4

    156.7

    159.8

    162.2

    165.5

    167.9

    171.3

    173.8

    177.3

    179.9

    183.5

    186.2

    189.9

    192.8

    196.6

    199.5

    203.5

    206.5

    210.7

    218.1

    225.7

    229.1

    233.6

    241.8

    250.3

    254.1

    MAIN

    T X

    T

    M

    Push

    SETB

    MAIN

    T X

    T

    M

    [SET ]T and rt appear

    USINGSET MODE

    25

    4REPEATER OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    43/96

    26

    4

    D DTMF tones

    Push [DTMF-S], then push the keys of the de-

    sired DTMF digits. The function indicator lights green.

    09, AD, M(E) and #(F) are available.

    When d is displayed in place of the 100 MHz digit,

    cancel the DTMF memory encoder in advance.

    (p. 50)

    Push [DTMF-S] again to return the keypad to nor-mal function control.

    For your convenient!

    The transceiver has 14 DTMF memory channels for au-

    topatch operation. See p. 48 for details.

    D 1750 Hz tone

    The microphone has 1750 Hz tone capability, used for ring

    tone when calling, etc.

    z Push [FUNC]. The function indicator lights orange.

    x Push [M(TONE-1)] to transmit a 1750 Hz tone

    call signal for 0.5 sec.; push and hold

    [0(TONE-2)] to transmit a 1750 Hz tone call

    signal for an arbitrary period. The function indicator goes out automatically.

    Push ,

    then or .

    TONE-1

    TONE-2

    then push desired keys.

    Push ,

    DTMF-S

    4 REPEATER OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    44/96

    27

    I Offset frequencyWhen communicating through a repeater, the transmit fre-

    quency is shifted from the receive frequency by an amount

    determined by the offset frequency.

    Independent offset frequencies can be set for each operating

    frequency.

    qPush [MAINBAND] to select the desired band (left or right)as the main band. Push [MAINBAND] for 1 sec. then rotate the [DIAL] to select the

    desired frequency band if necessary.

    wSelect the desired mode/channel you wish to set the offset

    frequency to, such as VFO mode or memory/call channel. The offset frequency can be independently programmed into

    each mode or channel.ePush [SET ] to enter set mode.rPush [SET ] or [LOWPRIO] until DUP and offset fre-

    quency appear.

    tRotate the main bands [DIAL] to set the desired offset fre-

    quency.

    yPush [TONEDTMF] to exit set mode.

    z Push [BAND] to select the desired band (left or

    right) as the main band. Enter the desired frequency via the keypad if neces-

    sary.

    x Select the desired mode/channel you wish to

    set the offset frequency to, such as VFO mode

    or memory/call channel. The offset frequency can be independently pro-

    grammed into each mode or channel.

    c Push [SET B(D-OFF)] to enter set mode.

    v Push [SET B(D-OFF)] or [ENT C(T-OFF)] until

    DUP and offset frequency appear.

    b Push [Y] or [Z] to set the desired offset.

    Direct frequency entry from the keypad is not possi-ble.

    n Push [CLR A(MW)] to exit set mode.

    NOTE: The offset frequency can be set in a memory/call

    channel temporarily. However, the set frequency is cleared

    once another memory channel or VFO mode is selected.

    To store the offset frequency permanently, overwrite thechannel information.

    MAIN

    T X

    DUP

    M

    Push

    SETB

    MAIN

    T X

    DUP

    M

    [SET ][LOWPRIO]DUP and offset frequency appear

    USINGSET MODE

    4REPEATER OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    45/96

    28

    4

    I Auto repeater(U.S.A. version only)

    The USA version automatically activates the repeater settings

    (DUP or DUP+ and tone encoder ON/OFF) when the operating

    frequency falls within the general repeater output frequency

    range and deactivate them when outside of the range.

    D Setting the auto repeater function ON/OFFq Push [PWR] to turn power OFF.

    wWhile pushing [SET ], turn power ON to enter initial set

    mode.

    e Push [SET ] or [LOWPRIO] several times until therPt display appears as shown above right.

    r Rotate left bands [DIAL] to select the auto repeater func-tion from r1,r2 or OFF.

    r1: auto repeater is ON, tone encoder is OFF.

    r2: auto repeater is ON, tone encoder is ON.

    t Push [PWR] to exit initial set mode.

    D Frequency range and offset direction

    MAIN

    T X

    DUP

    M

    MAIN

    T X

    DUP T

    M

    Auto DUP set: ONAuto tone set: OFF

    Auto DUP set: ONAuto tone set: ON

    While pushing [SET ]push [PWR] to enter initial

    set mode

    USING INITIAL SET MODE

    Frequency range Duplex direction

    145.200145.495 MHzDUP appears

    146.610146.995 MHz

    147.000147.395 MHz DUP appears442.000444.995 MHz DUP appears

    447.000449.995 MHz DUP appears

    MEMORY OPERATION5

  • 8/8/2019 Icom IC-2720H Instruction Manual

    46/96

    29

    I General descriptionThe transceiver has 212 memory channels including 10 scan

    edge memory channels (5 pairs), and 2 call channels. Each of

    these channels can be individually programmed with operating

    frequency (pgs. 1113), duplex direction (p. 23) and offset

    (p. 27), subaudible tone encoder or tone squelch and its tone

    frequency (pgs. 23, 25, 52, 53) and skip information* (p. 44).

    In addition, a total of 10 memory banks, A to J, are availablefor usage by group, etc.

    *except for scan edge memory channels.

    I Memory channel selectionD Using the tuning dial

    q Push the desired bands[M/CALL(MW)] several

    times to select memory

    mode. M indicator appears

    w Rotate the same bands[DIAL] to select the de-

    sired memory channel. Programmed memory

    channels only can be se-

    lected.

    D Using the [Y]/[Z] keys

    z Push [BAND] to select the desired band as

    the main band.

    x Push [MR/CALL] to select memory mode.

    c Push [Y] or [Z] to select and set the desired

    memory channel. Pushing [Y]/[Z] for 1 sec. activates a scan.

    If scan is activated, push [Y]/[Z] again or push

    [CLR A(MW)] to stop it.

    D Using the keypad

    z Push [BAND] to select the desired band as

    the main band.x Push [MR/CALL] to select memory mode.

    c Push [ENT C(T-OFF)] to activate the keypad

    for numeral input.

    v Push 3 appropriate digit keys to input a chan-

    nel number. Blank channel can be selected.

    Push only 1 appropriate digit key, [MONI 1(BANK)],

    [SCAN 2(T-SCAN)], [PRIO 3(PTT-M)],

    [HIGH 4(DTCS)] or [MID 5(DTCSS)] then push

    [M(TONE-1)] or [SQLZ #(16KEY-L)] to select scan

    edge channels. M and # can be used for A

    and b respectively.

    MR/CALL

    Y/Z

    MR/CALL

    Y/Z

    MAIN

    T X

    M

    Push [M/CALLMW] to selectmemory mode.

    ! appears

    5MEMORY OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    47/96

    30

    5

    I Programming a memory channel

    [EXAMPLE]: Programming 145.870 MHz into memory channel 20 (blank channel) via the controller.

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    Push Rotate for setting frequency, etc. Push for 1 sec.

    Rotate Push for 1 sec. and continue to pushS.MWMW

    BeepBeep

    BeepBeep

    BeepBeepBeep

    SCANV/MHz

    MWM/CALL

    VFO settings, including the set mode contents such as sub-

    audible tone frequency, offset, can be programmed into a

    memory channel.

    qSet the desired frequency in the desired band (left or right).

    Push the desired bands [V/MHzSCAN] to select VFO

    mode. Set the frequency using the same bands [DIAL]. Set other data (e.g. tone frequency, duplex information,

    etc.) if required.

    wPush the same bands [M/CALLMW] for 1 sec. 3 beeps sound

    ! indicator and the memory channel number blink.

    eRotate the [DIAL] to select the memory channel to be pro-

    grammed. Memory channels not yet programmed are blank.

    rPush the [M/CALLMW] for 1 sec. to program. 3 beeps sound

    Memory channel number automatically increases when contin-

    uing to push [M/CALLMW] after programming.

    CONVENIENT

    Memory programming can be performed in versatile ways

    e.g. memory channel to the same (or different) memory chan-

    nel, memory channel to the call channel, etc.

    5 MEMORY OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    48/96

    31

    D Programming a memory channel via the microphone

    [EXAMPLE]: Programming 145.870 MHz into memory channel 20 (blank channel) via the microphone.

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    Push

    Beep

    Beep

    BeepBeepBeep

    Push , Push then

    Push then for 1 sec. and continue to push

    The microphone can also be used to program mem-ory channels.

    z Set the desired frequency in VFO mode. Push [VFO/LOCK] to select VFO mode.

    Set the frequency using the keypad.

    Set other data (e.g. offset frequency, duplex direction, sub-audible tone encoder ON/OFF and its frequency), if neces-

    sary.

    x Push [FUNC] then [CLR A(MW)] momentarily.

    c Push [Y] or [Z] to select the memory channel.

    Direct numeral input cannot be used.

    v Push [FUNC] then [CLR A(MW)] for 1 sec. to program. 3 beeps may sound and the VFO contents (including

    the subaudible tone frequency, etc.) are programmed.

    Memory channel number increases when continuing topush [CLR A(MW)] after programming.

    MW

    5MEMORY OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    49/96

    32

    5

    I Transferring memory contentsThis function transfers a memory channels contents to VFO(or another memory/call channel). This is useful when search-

    ing for signals around a memory channel frequency and for

    recalling the offset frequency, subaudible tone frequency etc.

    DMemory/callVFO

    q Select the desired bands (left or right) memory or callchannel. Push the desired bands [M/CALLMW] several times to

    select memory mode or call channel, then rotate the

    same bands [DIAL] to select the desired memory or callchannel.

    w Push [M/CALLMW] for 1 sec. to transfer the selectedmemory/call channel contents to the VFO. VFO mode is selected automatically.

    z Push [BAND] to select the desired band as

    the main band, if necessary.x Select the memory/call channel to be

    transferred.

    Push [MR/CALL] to select memory mode,

    then select the desired memory channel

    via [Y]/[Z] or keypad.

    Push [MR/CALL] for 1 sec. then push

    [Y]/[Z] to select the call channel.c Push [FUNC], then [CLR A(MW)] for 1 sec. to

    transfer the selected memory/call channel

    contents to the VFO. VFO mode is selected automatically.

    MR/CALL

    MW

    [Y]/[Z]

    [EXAMPLE]: Transferring memory channel 30 contents to VFO.

    MAIN

    T X

    M

    MAIN

    T X

    DUP T

    M

    MAIN

    T X

    DUP T

    M

    Push to select memory mode.

    Front panel operation:

    HM-133 operation:

    Push to select memory mode.

    Rotate for selecting memory channel.

    Select memory channel.

    Push for 1 sec.

    Push then push for 1 sec.

    MWM/CALL

    MWM/CALL

    5 MEMORY OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    50/96

    33

    DMemory/callcall/memory

    q Select the memory/call channel to be transferred. Push the desired bands [M/CALLMW] several times to

    select memory mode or call channel, then rotate the

    same bands [DIAL] to select the desired memory or callchannel.

    w Push the same bands [M/CALLMW] for 1 sec. ! indicator and indication blink, and shows VFO condi-

    tions.

    e Rotate the [DIAL] to select the target memory channel. C1 or C2 blinks when the call channel is selected.

    Scan edge channels, 1A/1b, 2A/2b, 3A/3b, 4A/4B, 5A/5b can

    also be selected.

    r Push the [M/CALLMW] for 1 sec. to transfer the selectedmemory/call channel contents to the target memory. The targeted memory and transferred contents are indicated.

    z Select the memory/call channel to be trans-

    ferred. Push [MR/CALL] to select memory mode,

    then select the desired memory channel

    via [Y]/[Z] or keypad.

    Push [MR/CALL] for 1 sec. then push

    [Y]/[Z] to select the desired call channel.

    x Push [FUNC], then [CLR A(MW)] momentarily.

    ! indicator and indication blink, andshows VFO conditions.

    c Push [Y]/[Z] to select the target memory

    channel. C1 or C2 blinks when the call channel is selected.

    Scan edge channels can also be selected.

    The keypad cannot be used for the selection.

    v Push [FUNC] then push [CLR A(MW)] for1 sec. to transfer the selected memory/call

    channel contents to the target memory. The targeted memory and transferred contents

    are indicated.

    MR/CALL

    MW

    [Y]/[Z]

    [EXAMPLE]: Transferring memory channel 30 contents to channel 31.

    MAIN

    T X

    DUP T

    M

    MAIN

    T X

    M

    MAIN

    T X

    DUP T

    M

    MAIN

    T X

    DUP T

    M

    Select the target channel. Push for 1 sec.

    Push then push for 1 sec.

    Select the memory channel, then push for 1sec.

    Select the memory channel, push then push .

    Front panel operation:

    HM-133 operation:

    MWM/CALL

    MWM/CALL

    5MEMORY OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    51/96

    34

    5

    I Memory clearingContents of programmed memories can be cleared (blanked),

    if desired.

    q Push [V/MHzSCAN] to select VFO mode in the desiredband (left or right).

    w Push the same bands [M/CALLMW] for 1 sec.

    ! indicator and the memory channel number blink.e Rotate the same bands [DIAL] to select the memory chan-

    nel to be cleared. Memory channels not yet programmed are blank.

    r Push the same bands [M/CALLMW] momentarily, thenpush the [M/CALLMW] again for 1 sec. This operation must be performed within 1.5 sec.

    3 beeps sound, then the frequency is cleared.

    ! indicator and the channel number blink continuously.

    When clearing the call channel, the current VFO conditions are

    re-programmed into the call channel automatically.t Push the same bands [MAINBAND] or [V/MHzSCAN], toreturn to VFO mode.

    NOTE: Be careful! the contents of cleared memoriesCANNOT be recalled.

    [EXAMPLE]: Clearing memory channel 20.

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    Push to select VFO. Rotate for selecting memory channel.Push for 1 sec.

    Push any switch, except .Push momentarily, then push again for 1 sec.

    BeepBeepBeep

    MWM/CALL

    MWM/CALL

    MWM/CALL

    MWM/CALL

    SCANV/MHz

    5 MEMORY OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    52/96

    35

    I Memory bank selectionThe IC-2720H has a total of 10 banks (A to J). Regular mem-

    ory channels, 000 to 199, are assigned into the desired bank

    for easy memory management.

    q Push the desired bands[M/CALLMW] severaltimes to select memorymode, if desired.

    w Push the same bands[MAINBAND] for 1 sec.to select memory bankcondition. Bank initial blinks

    e Rotate the same bands

    [DIAL] to select the de-sired bank, A to J. Banks that have no pro-

    grammed contents are

    skipped.

    r Push the [MAINBAND] to set the bank. Initial stops blinking.

    t Rotate the [DIAL] to select the contents in the bank. No channel numbers are displayed for memory bank operation.

    y To return to regular memory condition, push the

    [MAINBAND] for 1 sec. then push the [MAINBAND] mo-mentarily again.

    z Push [MR/CALL] to select memory mode, if de-

    sired.x Push [FUNC] then [MONI 1(BANK)] to select

    memory bank condition. Bank initial blinks

    c Push [Y]/[Z] to select the desired bank, A to J.

    Only programmed memory bank can be selected.v Push [CLR A(MW)] to set the bank.

    Initial stops blinking.

    b Push [Y]/[Z] to select the desired contents in

    the bank. No channel numbers are displayed for memory

    bank operation.

    n To return to regular memory condition, push[FUNC], [MONI 1(BANK)] then push [CLR A(MW)].

    BANK

    [Y]/[Z]

    MAIN

    T X

    M

    Push [MAINBAND] for 1 sec.to select memory bank.

    Bank initial appears

    5MEMORY OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    53/96

    36

    5

    I Memory bank settingq Push the desired bands [M/CALLMW] several times to

    select memory mode, then select the desired memory

    channel via the same bands [DIAL].w Push the same bands [MAINBAND] for 1 sec.

    indication blinks as follows.

    e Push the [MAINBAND] again to set the channel to banksetting stand-by condition.

    indication blinking stops.r Push the [M/CALLMW] for 1 sec. then rotate the [DIAL] to

    select the desired bank to be set. Bank initial blinks as follows.

    t Push the [M/CALLMW] again to set the channel into thebank. ! and bank initial blinking stops.

    y Push the [MAINBAND] for 1 sec. then push the[MAINBAND] momentarily again to return to regular mem-ory condition.

    u Repeat stepsq toy to set another memory channel into

    the same or another bank.

    z Push [MR/CALL] then select the desired mem-ory channel via [Y]/[Z] or keypad. Push [BAND] to select the desired band (left or

    right) as the main band, in advance.

    x Push [FUNC] then [MONI 1(BANK)]. indication blinks.

    c Push [CLR A(MW)] to set the channel to bank

    setting stand-by condition. indication stops blinking.

    v Push [FUNC] then [CLR A(MW)] then push

    [Y]/[Z] to select the desired bank to be set. Bank initial blinks.

    b Push [CLR A(MW)] to set the channel into the

    bank. ! and bank initial stops blinking.

    n Push [FUNC], [MONI 1(BANK)] then [CLR A(MW)]

    to return to regular memory channel condition.m Repeat stepsz ton to set an another memory

    channel into the same or another bank.

    BANK

    [Y]/[Z]

    MW

    MAIN

    T X

    M

    MAINT X

    M

    5 MEMORY OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    54/96

    37

    I Transferring bank contentsContents of programmed memory banks can be cleared or

    transferred to another bank.

    INFORMATION: Even if the memory bank contents are

    cleared, the memory channel contents still remain pro-

    grammed.

    q Select the desired bank contents to be transferred or

    erased in the desired band (left or right). Push the desired bands [M/CALLMW] several times to

    select memory mode.

    Push the same bands [MAINBAND] for 1 sec. then ro-tate the same bands [DIAL] to select the desired mem-

    ory bank. Bank initial blinks.

    Push the [MAINBAND] to select the bank then rotatethe [DIAL] to select the desired contents. Bank initial stops blinking.

    w Push the [M/CALLMW] for 1 sec. Bank initial blinks.

    e Rotate the [DIAL] to select the desired bank initial to trans-

    fer or erase.

    Select indication when erasing the contents from the bank.

    r Push the [M/CALLMW] again. Bank initial or indication stops blinking.

    t Push the [MAINBAND] for 1 sec. then push the[MAINBAND] momentarily again to return to regular mem-ory condition.

    y Repeat steps q to t for transferring or erasing an an-

    other banks contents.

    z Select the desired bank contents in the main

    band.

    Push [MR/CALL] to select memory mode. Push [FUNC], [MONI 1(BANK)] then select

    the desired memory bank via [Y]/[Z].

    Push [CLR A(MW)] to select the bank then

    select the desired contents via [Y]/[Z].x Push [FUNC] then [CLR A(MW)].

    Bank initial blinks.

    c Push [Y]/[Z] to select the desired bank initial to

    transfer or erase. Select indication when erasing the contents

    from the bank.

    v Push [CLR A(MW)]. Bank initial or indication stops blinking.

    b Push [FUNC], [MONI 1(BANK)] then [CLR A(MW)]

    to return to regular memory condition.

    n Repeat steps z to b for transferring or eras-

    ing an another banks contents.

    BANK

    [Y]/[Z]

    MW

    MAIN

    T X

    M

    6CALL CHANNEL OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    55/96

    38

    5

    6

    I Call channel selectionCall channel is pre-programmed memory channel that can be

    accessed by simply pushing call channel button.

    Push [M/CALLMW] sev-eral times to select the

    call channel mode then

    rotate the same bands[DIAL] to select the de-

    sired call channel. C1 or C2 appears in-

    stead of memory channel

    number indication.

    Push the [M/CALLMW] sev-

    eral times to select memory

    mode, or push the same

    bands [V/MHzSCAN] to se-

    lect VFO mode.

    Push [MR/CALL] for 1 sec. to select the call

    channel mode then push [Y]/[Z] to select the

    desired call channel in the main band.

    Push [MR/CALL] to select memory mode, or push[VFO/LOCK] to select VFO mode.

    I Call channel transferringq Push the desired bands [M/CALLMW] several times then

    rotate the same bands [DIAL] to select the desired callchannel. C1 or C2 appears.

    w Push the [M/CALLMW] for 1 sec., then rotate the [DIAL] toselect the memory channel to transfer the contents to.

    ! indicator and memory channel number blink. To transfer to the VFO, select with the [DIAL] then push the

    [M/CALLMW] for 1 sec.

    e Push the [M/CALLMW] for 1 sec. to transfer the contents.

    z Push [MR/CALL] for 1 sec. then push [Y]/[Z]

    to select the desired call channel in the main

    band.x Push [FUNC], [CLR A(MW)] momentarily, then

    push [Y]/[Z] to select the memory channel to

    transfer the contents to. To transfer to the VFO, push [Y]/[Z] to select

    then push [FUNC], [CLR A(MW)] for 1 sec.

    c Push [FUNC], then [CLR A(MW)] for 1 sec. to

    transfer the contents.

    MR/CALL

    MW

    [Y]/[Z]MR/CALL

    MAIN

    T X

    M

    Push [M/CALLMW] several timesto select call channel.

    C1 or C2 appears

    INFORMATIONMAIN

    T X

    M

    When the VFO mode isselected from the call channel,a small c appears instead of

    memory channel number.

    6 CALL CHANNEL OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    56/96

    39

    I Programming a call channel

    Operating frequency, duplex information, subaudible tone in-

    formation (tone encoder or tone squelch ON/OFF and its fre-

    quency) can be programmed into the call channel.

    q Set the desired frequency in VFO mode. Push the desired bands [V/MHzSCAN] to select VFO

    mode. Set the frequency using the same bands [DIAL]. Set other data as desired.

    w Push the same bands [M/CALLMW] for 1 sec.e Rotate the [DIAL] to select the desired call channel.

    ! indicator and C1 or C2 blink.

    r Push the [M/CALLMW] for 1 sec. to program. 3 beeps sound and the unit returns to VFO mode automatically.

    z Set the desired frequency in VFO mode. Push [VFO/LOCK] to select VFO mode.

    Set the frequency.

    Set other data as desired.x Push [FUNC], then [CLR A(MW)] momentarily.c Select the call channel via [Y] or [Z] .

    v Push [FUNC] then [CLR A(MW)] for 1 sec. to

    program. 3 beeps sound and the unit returns to VFO mode

    automatically.

    MR/CALL

    MW

    [Y]/[Z]

    [EXAMPLE]: Programming 145.120 MHz into the call channel 2 via the microphone.

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    Set the frequency.Push to select VFO mode. Push , then .

    Push , then push for 1 sec.Push until large C appears.

    BeepBeepBeep

    7SCAN OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    57/96

    40

    67

    I Scan types

    Scanning searches for signals automatically and makes it

    easier to locate new stations for contact or listening purposes.

    There are 3 scan types and 4 resume conditions to suit your

    operating needs.

    BAND SCAN (p. 41) Repeatedly scans all frequen-cies over the entire band.

    Used as the simplest scan

    without any preliminary set-

    tings necessary.

    Bandedge Bandedge

    Scan

    Jump

    PROGRAMMED SCAN(p. 41)

    Repeatedly scans between

    two user-programmed fre-

    quencies. Used for checking

    for frequencies within a speci-

    fied range such as repeater

    output frequencies, etc.

    5 pairs of scan edges are

    available and scans 1A1b(P1), 2A2b (P2), 3A3b (P3),

    4A4b (P4), 5A5b (P5).

    Bandedge

    Bandedge

    Scan edges

    Scan

    Jump

    1A2A3A4A5A

    1b2b3b4b5b

    Start End

    MEMORY SCAN (p. 41) Repeatedly scans memorychannels except those set as

    skip channels. Used for often-

    called channels and for by-

    passing normally busychannels such as repeater

    frequencies.

    SKIP

    SKIP

    M 0 M 4

    M 1 M 2 M 3

    M 5M 199 M 6

    SCAN RESUMECONDITION (p. 45)

    4 resume conditions are avail-

    able: 3 timer scans and pause

    scan. When receiving a sig-

    nal, pause scan pauses until

    the signal disappears; timerscans pause for 5, 10 or

    15 sec.

    Pausescan

    Receivinga signal

    Timerscan

    Pausing

    2 sec.

    NOTE: A tone scan function is available to search for subaudible tones (e.g. when you want to find a subaudible tone fre-quency necessary to open a repeater). See p. 55 for details.

    7 SCAN OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    58/96

    41

    I Scan start/stopD PreparationScan resume condition (p. 45); program the scan edges

    (pgs. 42, 43); program 2 or more memory channels (pgs. 30,

    31); set skip settings, if desired (p. 44).

    D Operation

    q Select VFO mode for full/programmed scan with[V/MHzSCAN]; or memory mode for memory scan with[M/CALLMW] in the desired band. Select the desired bank with the same bands [MAINBAND] for

    bank scan.

    w Set the squelch to the point where noise is just muted.e Push the [V/MHzSCAN] for 1 sec. to start the scan.

    To change the scanning direction, rotate the same bands [DIAL]. The memory channel readout blinks the scan type as follows:

    r Push [SET ] to switch full and programmed scan (P1,

    P2, P3, P4 and P5), if VFO is selected in stepq.t To stop the scan, push the [V/MHzSCAN].

    z Push [VFO/LOCK] to select VFO mode for

    full/programmed scan; push [MR/CALL] to select

    memory mode for memory scan, in the main

    band. Push [FUNC] then [MONI 1(BANK)] to select a bank

    for bank scan.

    x Push [SQLY D(MUTE)] or [SQLZ #(16KEY-L)] to

    set the squelch to the point where noise is just

    muted.

    c Push [SCAN 2(T-SCAN)] to start the scan. Push [Y] or [Z] for 1 sec. also starts the scan.

    v Push [SET B(D-OFF)] to switch full and pro-

    grammed scan (P1, P2, P3, P4 and P5), if VFOis selected in stepz.b To stop the scan push [SCAN 2(T-SCAN)] or

    [CLR A(MW)].

    SCAN2

    SETB

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    During full scan During programmed scan During memory scan During bank scan

    Indicates scan edge channels. P1 stands for 1A/1b P1 to P5 are available when they

    are programmed, and switcheswith [SET ].

    Indicates bank initial.Push [SET ] to select AL(full) or programmed scan (P1,P2, P3, P4 and P5) in

    sequence.

    7SCAN OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    59/96

    42

    7

    I Scan edges programming

    Scan edges can be programmed in the same manner as

    memory channels. Scan edges are programmed into scan

    edges, 1A/1b to 5A/5b, in memory channels.

    q Set the edge frequency of the desired frequency range in

    VFO mode:

    Set the frequency using the desired bands [DIAL]. Set other data (e.g. repeater settings, etc.) if desired.

    w Push the same bands [M/CALLMW] for 1 sec. M indicator and channel number blink.

    e Rotate the [DIAL] to select one of scan edge channel, 1A,

    2A, 3A, 4A or 5A.

    r Push the [M/CALLMW] for 1 sec. to program. 3 beeps sound and VFO is automatically selected.

    Scan edge 1b, 2b, 3b, 4b or 5b is automatically selected when

    continuing to push the [M/CALLMW] after programming.

    t To program a frequency for the other pair of scan edges,

    1b, 2b, 3b, 4b or 5b, repeat stepsq andr.

    If the same frequency is programmed into a pair of scan edges,programmed scan will not function.

    [EXAMPLE]: Programming 145.300 MHz into scan edges 1A.

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    Push for 1 sec.Rotate for setting frequency, etc. Rotate

    Push for 1 sec. and continue to push

    BeepBeepBeep

    Beep

    MWM/CALL

    MWM/CALL

    7 SCAN OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    60/96

    43

    D Programming scan edges via microphone

    z Set the desired frequency in VFO mode. Push [VFO/LOCK] to select VFO mode. Set the frequency via the keypad or [Y]/[Z].

    x Push [FUNC] then [CLR A(MW)] momentarily.

    c Push [Y] or [Z] to select scan edge channels,

    1A, 2A, 3A, 4A or 5A.

    v Push [FUNC], then push [CLR A(MW)] for 1 sec.

    to program. 3 beeps sound and VFO is automatically selected.

    Memory channel number advances to the next scan

    edge channel, 1b, 2b, 3b, 4b or 5b when continuing to

    push [CLR A(MW)] after programming.

    b To program a frequency for the other scan edge channels,repeat stepsz tov.MW

    [EXAMPLE]: Programming 145.800 MHz into scan edge 1b.

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    MAIN

    T X

    M

    Push Push Push then momentarily

    Push Push then for 1 sec. and continue to push

    BeepBeepBeepBeep

    7SCAN OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    61/96

    44

    7

    I Skip channel setting

    The memory skip function speeds up scanning by checking

    only those memory channels not set as skip channels. Set

    skip channels as follows.

    q Select a memory channel in the desired band:

    Push the desired bands [M/CALLMW] to select mem-ory mode. Rotate the same bands [DIAL] to select the desired

    channel to be a skip channel.w Push [SET ] to enter set mode.

    e Push [SET ] or [LOWPRIO] several times until CHSappears as shown above.

    r Rotate the [DIAL] to turn the skip function ON or OFF forthe selected channel. ~ appears : The channel is skipped during scan.

    (CHS-On)

    ~ disappears : The channel is scanned during scan.

    (CHS-OF)

    t Push [TONEDTMF] to exit set mode.

    z Select a memory channel.

    Select memory mode by pushing [MR/CALL]. Push [Y] or [Z] to select the desired channel

    to be a skip channel.

    Direct memory channel selection is also available.x Push [SET B(D-OFF)] to enter set mode.

    c Push [SET B(D-OFF)] or [ENT C(T-OFF)] several

    times until CHS appears as shown at left.v Push [Y] or [Z] to set or cancel the skip setting.

    See itemr at left for skip indicator details.

    b Push [CLR A(MW)] to exit set mode.

    SETB

    MAIN

    T X

    MSKIP

    The display shows that memo-ry channel 1 is set as a skipchannel.

    USINGSET MODE

    7 SCAN OPERATION

  • 8/8/2019 Icom IC-2720H Instruction Manual

    62/96

    45

    I Scan resume condition

    The scan resume condition can be selected as timer or pause

    scan. The selected resume condition is also used for priority

    watch. (p. 47)

    q Push [MAINBAND] to select the desired band (left or right)

    as the main band.w Push [SET ] to enter set mode.

    e Push [SET ] or [LOWPRIO] several times until SCtor SCP appears as shown above. When d is displayed in place of the 100 MHz digit, cancel the

    DTMF memory encoder in advance. (p. 50)

    r Rotate the main bands [DIAL] to set the desired timer:

    SCt-15 : Scan pauses 15 sec. while receiving a signal. SCt-10 : Scan pauses 10 sec. while receiving a signal.

    SCt-5 : Scan pauses 5 sec. while receiving a signal.

    SCP-2 : Scan pauses until the signal disappears and then

    resumes 2 sec. later.

    t Push [TONEDTMF] to exit set mode.

    z Push [BAND] to select the desired band (left or

    right) as the main band.