I1000 d ugm
-
Upload
interlatin -
Category
Technology
-
view
264 -
download
1
Transcript of I1000 d ugm
i1000D with JET Board
Handler
The Key Points about the Handler
Simple but Robust Design
High upper and lower clearance for tall components
Left to Right or Right to Left. Needs to be specified upon
ordering
Knowing the Knobs and Buttons
Status Indicator Tower
LCD monitor
Keyboard & Mouse Tray
i1000D Testhead
Test section with door
Operation Buttons
Page 4
Value
Q
D
JP
Formatting the BOM
Page 5
Resistor Test
Test Mode
CV Mode = Constant Voltage (Max 100mA)
CC Mode = Constant Current (Max 2.5V)
A
R ADC V
B
I R = V
I
CC mode (Low resistance)
CV mode (High resistance) with guarding
Current based on
UUT resistance
100mV
CC guarding
--------------
+++++++++++++
R1 R2
V+V-
A
EAB
When voltage is applied to correct terminals
of a capacitor, it starts charging
We can use R1 and R2 and R3 to simulate. R2 >> R1
because case is mostly tied to negative input.
Voltage between V+ and casing is high because R2>> R1.
Voltage between V- and casing is low.
R3
Electrolytic Capacitor Polarity Test
A
B EA
Page 7
Card Cage Front View
i1000D System Overview
Parts in the Testhead
Measurement Card
Pin Cards – Max of 27pcs
Switch PS modules
Linear PS Board
N6700 DUT PS Unit
PC Controller
System Switch Box
Types of Pin Cards
HV DUT PS Card
DUT PS Card
64 channels Hybrid Pin Card
128 channels Analog Pin card
Page 8
DUT Power Supplies
Types of DUT Power Supplies
System
IO Card
DUT Power Supply Card
HV DUT Power Supply Board
N6700 DUT Power Supply
(4x 6751A)
Channel Output DUT
Power Supply
HV DUT
Power Supply
N6700 DUT Power
Supply
Programmable Chn 1 0~ 5V @ 20A 0~ 5V @ 20A 0~50V @ 5A
Programmable Chn 2 0~ 5V @ 20A 10~ 100V @ 10mA 0~50V @ 5A
Programmable Chn 3 0~ 20V @ 4A 0~ 14V @ 10A 0~50V @ 5A
Programmable Chn 4 0~ -14V @ 5A 0~ -14V @ 5A 0~50V @ 5A
Note : Chn2 of HV DUT PS is used only for Zener Diode tests.
The Control Buttons
Press Up/Down
Left Side and Right Side
Clearance is 20mm
i1000D shows error message when internal temperature > 45 C
Cooling Fans
IN-LINE left side view IN-LINE right side view
Cooling Fans
Main Power
i100D TestheadPower
Controller Power
Compressed air input
Handler Rear View
Compressed air gauge
Electro-MagneticValves for Conveyor, Fixture lock and Board stopper
Electro-MagneticValves for Board Markers
Main Press Down Unit Cylinder
Right Bottom Corner from Back Side
Power connector
Loader signal connector(SMEMA Compatible)
Un-loader signal connector(SMEMA Compatible)
IN
OUT
OUT
SEMEMA INTEFACE
JET I1000 IN_LINE
SHIELD
JR4
AMP_CIR
1
2
345
67
91011
12
13
14
8
TO UNLOAD MACHINE
IN
OUTSHIELD
JR5
AMP_CIR
1
2
345
67
91011
1213
14
8ICT_READY+
ICT_READY-
LOAD_AVAILABLE-
LOAD_AVAILABLE+ UNLOAD READY -
UNLOAD READY +
ICT AVAILABLE-
ICT AVAILABLE+
OK_NG+
OK_NG-
SMEMA Interface
Inside the Front Door
Down Fixture
Rail fix bolt
Press Down Unit
Rail width adjustor
Conveyor Belt
Upper Fixture
FixtureInterface
On the Conveyor
Board Flatness Alignment Sensor
Board Stopper
Slow down triggeringsensor
Double-load sensor
The Board Alignment Switched Probes
Adjusting the Sensors for Loading
Dual Load Sensor
Board Flatness Alignment Sensor (not used)
Motor slow down sensor
Around 2 times of UUT length
More than 8 cm