HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design...

37
HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008 In the Medusa permanent- magnet system

Transcript of HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design...

Page 1: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

HYDROGEN HELICONS

Part 1: Preliminary considerations

Part 2: Design for high density

Part 3: Design for low density

Francis F. Chen, UCLA, October, 2008

In the Medusa permanent-magnet system

Page 2: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Hydrogen helicons in Medusa 2 tube

0

2

4

6

8

10

12

14

0 20 40 60 80 100

B-field (G)

Lo

we

r h

ybrid

fre

qu

en

cy (

MH

z)

Hydrogen

Argon

13.56 MHzn = 1E12 cm-3

z

nk

k B

The lower hybrid frequency LH) is 6.5 times higher for H than for Ar and is not << (RF). To neglect ion motions, need to have (RF) >> (LH). Need to decrease B to have lower (LH), but low B means bad coupling, like ICPs. Since k is same if we keep 2” diam tube, we have to increase (RF) and change n and kz.

Page 3: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Meaning of the lower hybrid frequency

2 2

1 1 1

c cLH p

The lower hybrid frequency LH is given by

where p is the ion plasma frequency.

The last term is negligible except at very low density, so LH is proportional to B/M.

In simple helicons, is >> LH and c, so the ions cannot move with the RF. When LH approaches RF, the ions will move and contribute to the helicon current. Scime et al. have seen increased ion temperatures when ~ LH, but HELIC does not show any great effect there. At LH, the ion and electron orbits to B look like this:

The blue line is the ion cyclotron orbit, which has been distorted by the LH wave. The red line is the orbit of the electron guiding-center E x B drift. The cyclotron orbits of the electrons is too small to see.

Page 4: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Hydrogen RnB scans for 13.56 MHz

0.00

0.10

0.20

0.30

0.40

0.50

0.60

1E+10 1E+11 1E+12n (cm-3)

R (

oh

ms)

20

40

60

80

B (G)H = 1.0 in. conducting

13.56 MHz

0.0

0.1

0.2

0.3

0.4

0.5

0.6

1E+10 1E+11 1E+12n (cm-3)

R (

oh

ms)

20

40

60

80

B (G)H = 1.5 in. conducting

13.56 MHz

0.0

0.1

0.2

0.3

0.4

0.5

0.6

1E+10 1E+11 1E+12n (cm-3)

R (

oh

ms)

20

40

60

80

H = 1.5 in. insulatingB (G)

13.56 MHz

0.0

0.1

0.2

0.3

0.4

0.5

0.6

1E+10 1E+11 1E+12n (cm-3)

R (

oh

ms)

5

10

15

20

B (G) H = 2.0 in. conducting

13.56 MHz

No stable solution for hydrogen. Here, H is distance from antenna to endplate.

Page 5: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1E+11 1E+12 1E+13n (cm-3)

R (

oh

ms)

10

30

50

70

90

H = 1.0" conductingB (G)

27.12 MHz

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1E+11 1E+12 1E+13n (cm-3)

R (

oh

ms)

20

40

60

80

H = 1.5" conducting

B (G)

27.12 MHz

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1E+11 1E+12 1E+13n (cm-3)

R (

oh

ms)

20

40

60

80

B (G)

H = 1.5 in. insulating

27.12 MHz

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1E+11 1E+12 1E+13n (cm-3)

R (

oh

ms)

20

40

60

80

100

H = 3.0 in. conducting27.12 MHz

B (G)

There are stable solutions, but n has to be high, requiring LOTS of power.

Hydrogen RnB scans for 27.12 MHz

Page 6: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Radial deposition profiles

0

500

1000

1500

2000

2500

0 0.005 0.01 0.015 0.02 0.025r (m)

P (

r)

1.0E+11

1.6E+11

2.5E+11

4.0E+11

6.3E+11

1.0E+12

n (cm-3) H = 1.5", conducting, 80G, 13.56 MHz

0

1000

2000

3000

4000

0 0.005 0.01 0.015 0.02 0.025r (m)

P (

r)

1.0E+11

1.6E+11

2.5E+11

4.0E+11

6.3E+11

1.0E+12

1.6E+12

2.5E+12

4.0E+12

1.0E+13

n (cm-3)H = 1.0", conducting 90G, 27.12 MHz

There is not much difference between 13 and 27 MHz. The TG peak at the edge is wider than for argon, probably because the radial group velocity of the TG waves is faster for hydrogen.

Page 7: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Compare hydrogen at 27.12 MHz with argon at 13.56 MHzto get an idea of how the discharges behave in the standard 2” diam tube

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

1E+11 1E+12 1E+13n (cm-3)

R (

ohm

s)

75

50

25

Argon, 13.56 MHzH = 2"

B (G)

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1E+11 1E+12 1E+13n (cm-3)

R (

ohm

s)

75

50

25

Hydrogen, 27.12 MHzH = 2"

B (G)

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

1E+11 1E+12 1E+13n (cm-3)

R (

ohm

s)

100

75

50

Argon, 13.56 MHzH = 3"

B (G)

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1E+11 1E+12 1E+13n (cm-3)

R (

ohm

s)

125

100

75

Hydrogen, 27.12 MHzH = 3"

B (G)

H is essentially the tube length

Page 8: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1E+11 1E+12 1E+13n (cm-3)

R (

ohm

s)

100

80

60

40

20

Argon, 13.56 MHzB (G)

0

1000

2000

3000

4000

0.000 0.005 0.010 0.015 0.020 0.025r (m)

P(r

) (a

rb.)

100G, 1.6E1240 G, 6.3E11

Argon @ 13.56 MHz

0

1

2

3

4

-1.00 -0.95 -0.90 -0.85z(m)

P(z

) (a

rb.)

100G, 1.6E12

40 G, 6.3E11

Argon @ 13.56

How does the power deposition look in normal Ar discharges?

Here P(z) and P(r) are the power deposition profiles in z and r, and P(k) is the power spectrum. The cases are at two low-field peaks, and the spectrum is almost a pure mode. The dashed line is the location of the antenna.

0.000

0.004

0.008

0.012

0.016

0.020

0.024

0.028

0 25 50 75 100k (m-1)

P(k

) (a

rb.)

100G, 1.6E12

40 G, 6.3E11

50G, 3E11

Argon @ 13.56

Hydrogen, 50G, 3E11 @ 27.12 MHz

Page 9: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

0

200

400

600

800

1000

1200

1400

0.000 0.005 0.010 0.015 0.020 0.025r (m)

P(r

) (a

rb.)

Hydrogen

ArgonR = 0.564R = 0.397

0

1

2

3

4

-1.00 -0.95 -0.90 -0.85z(m)

P(z

) (a

rb.)

Hydrogen

Argon

0.000

0.002

0.004

0.006

0.008

0.010

0 20 40 60 80 100k(m-1)

P(k

) (a

rb.)

Argon

Hydrogen

This compares the profiles for argon and hydrogen in the same 2 x 2” tube and at the same conditions: B = 50G and n = 3 x 1011 cm-3. However, f = 13.56 MHz for argon and 27.12 MHz for hydrogen.

Page 10: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Calculation of plasma loss rate (1)

2 ½ 5tot c e e eW E KT KT KT

The energy needed to replace each electron-ion pair lost to the wall is

F.F. Chen and J.P. Chang, Principles of Plasma Processing (Kluwer, 2003), pp. 71-72

Here Ec is the energy needed to perform each ionization, including other inelastic losses incurred in the process. 2KTe is the average energy carried out by each electron. The ion energy carried out consists of the Bohm energy at the sheath edge, ½KTe, and the sheath drop, about 5KTe. The power lost is Wtot times the particle flux to the walls.

/ ½ sdN dt nc S

Here ½n is the density at the sheath edge, n being the peak density. This assumes few collisions. At higher pressures, the edge density will be even lower. Ions go out at the Bohm velocity cs, which is the acoustic velocity. S is the total area of the tube, including top, bottom, and sides. The required RF power is then

( / )rf totP W dN dt

Page 11: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Calculation of plasma loss rate (2)If Ec were the same for hydrogen as for argon, the loss rate would be 40 times higher for H than for Ar, since cs varies as M-1/2. For a tube 2” is diameter by 2” long, Prf works out to be

Prf (W) = 1.7 10-10 n (Argon) = 1.2 10-9 n (Hydrogen)

They are, of course, proportional to n. Ec will be discussed on the next page.

The power delivered to the plasma is less than Prf because of the circuit resistance Rc.

pin rf

p c

RP P

R R

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0E+00 1E+12 2E+12 3E+12 4E+12 5E+12 6E+12

n (cm-3

)

Po

we

r

Gain

Loss

10

100

1000

1E+11 1E+12 1E+13n0 (cm-3)

Pin

(W

)

1000

500

200

100

Loss

Prf (W)

If Rp < Rc, Pin follows the low-field peak curve, as on the left, and there is the possibility that the loss line will not intersect the Pin curve. But if Rc > ~3, Pin is almost all of Prf, as on the right. Then there is an operating point regardless of how large Ec is.

See F.F. Chen and H. Torreblanca, Plasma Sources Sci. Technol. 16, 593 (2007).

Page 12: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Calculation of plasma loss rate (3) The calculation of Ec involves summing up all the inelastic-collison energy that an electron loses, on the average, before it ionizes an ion. Most of the energy is lost to radiation of spectral lines after the electron raises an atom to an excited state. For argon, this function of Te was computed by Vahid Vahedi in his Ph.D. thesis under Prof. C.K. Birdsall of Berkeley. It is given for Ar, O, and O2 by Lieberman and Lichtenberg, 2nd ed., p. 82. It has probably not been computed for other gases.

An ionization coefficient measured in gas discharges is given on the next page. It shows that hydrogen is harder to ionize in spite of the fact that it has a lower ionization potential. Thus, the loss line for hydrogen may be steeper than for argon for two reasons: faster loss rate and slower ionization. This is the reason that more power is required to achieve a given density for hydrogen than for argon.

However, ionization of hydrocarbon molecules would be easier than for pure hydrogen.

Page 13: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Ionization coefficient in gas dischargesS.C. Brown, Basic Data of Plasma Physics (AIP Press, 1994).

(reprint of 1959 original)

The coefficient is the number of ionizations an electron makes after traveling through a voltage drop of 1 V. It is a function of E/p, in (V/cm)/torr.

These scans were resized so that the horizontal scales are the same, and the vertical scales end at 0.02. The blue line is where the hydrogen graph starts. Note that hydrogen needs a higher E-field to start, but it reaches its peak at about the same E/p as argon. However, these data assume much higher pressures than mTorrs.

The ionization potentials are 15.7 eV for argon and 13.5 eV for hydrogen.

Hydrogen

Page 14: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

HYDROGEN HELICONS

Part 1: Preliminary considerations

Part 2: Design for high density

Part 3: Design for low density

Francis F. Chen, UCLA, October, 2008

Page 15: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Redesign of helicon tubes for hydrogen operation

1. Tube I.D. ~ 5 cm, antenna ID ~7 cm, as before, unless otherwise specified.

2. The gap of 2 cm is slightly less conservative than assumed before.

3. RF frequency assumed to be 27.12 MHz

4. H is the distance between the antenna midplane and the conducting or insulating endplate.

5. Assumed 15 mTorr, KTe = 3 eV, n(r) given by s = 4, t = 1, fa = 0.3.

Page 16: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

1E+11 1E+12 1E+13n (cm-3)

R (

oh

ms)

140

120

100

B (G)

H = 1.5", conducting

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

1E+11 1E+12 1E+13n (cm-3)

R (

oh

ms)

140

120

100

B (G)

H = 2.0", insulating

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

1E+11 1E+12 1E+13n (cm-3)

R (

oh

ms)

140

120

100

B (G)

H = 2.5", insulating

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

1E+11 1E+12 1E+13n (cm-3)

R (

oh

ms)

140

120

100

B (G)

H = 3", insulating

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

1E+11 1E+12 1E+13n (cm-3)

R (

oh

ms)

140

120

100

B (G)

H = 3.5", insulating

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

1E+11 1E+12 1E+13n (cm-3)

R (

oh

ms)

140

120

100

B (G)

H = 4",

Loading resistance vs. n and B curves for varying H

In all cases, highest B is best. The conducting endplate is much better than the insulating ones.

Page 17: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

1E+11 1E+12 1E+13n (cm-3)

R (

oh

ms)

2.0

2.5

3.0

3.5

4.0

H (in.)

B = 140 G, insulating endplate

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

1E+11 1E+12 1E+13n (cm-3)

R (

oh

ms)

1.5

1.0

2.0

2.5

3.0

0.5

H (in.)

B = 140 G, conducting endplate

RnB curves vs. H atB = 140G.

For insulating endplates,H = 2.5” is best.

Loading is higher for conducting endplates

H = 1.5” is best. It seems to be a pure mode with the highest loading. We therefore choose this case for further analysis.

Page 18: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

0

2000

4000

6000

8000

0 0.005 0.01 0.015 0.02 0.025r (m)

P(r

)

1.5", conduct.

3.5", insul.

140G, 1.3E12H (in.), endplate

0

0.01

0.02

0.03

0.04

0.05

0 20 40 60 80 100 120 140k (m-1)

P(k

)

1.5", conduct.

3.5", insul.

140G, 1.3E12 H (in.), endplate

Both are near density peak, but conducting case has pure mode.

Power deposition profiles for two very different cases

P(r) is dominated by the TG mode and does not vary much.

P(z) peaks near the antenna (dashed line in each case). High P near endplate is not good, since plasma created there is lost fast.

The k-spectrum is pure for H = 1.5” but has other modes for H = 3.5”, as seen by the wiggles in the RnB curve on the last page.0

1

2

3

4

5

6

7

-1.00 -0.95 -0.90 -0.85 -0.80z (m)

P(z

)

1.5", conduct.

3.5", insul.

140G, 1.3E12

H (in.), endplate

R = 1.41

R = 1.67

Page 19: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

0

1

2

3

4

5

6

-1.00 -0.95 -0.90 -0.85 -0.80z (m)

|Ez|

(z)

H = 1.5"

H = 3"

140G, 1.4E12, conducting

R = 1.67

R = 0.87

140G, 1.3E12, conducting

0

1

2

3

4

5

6

7

-1.00 -0.95 -0.90 -0.85 -0.80z (m)

P(z

)

H = 1.5 in.

H = 3 in.

140G, 1.3E12, conducting

140G, 1.4E12, conducting R = 1.67

R = 0.87

Comparison of waves in 1.5 in. and 3 in. long tubes

The short tube has higher P(z), but it is high near the endplate. The electric field |Ez|, however, fits properly , whereas it is too short for the 3” tube. The maximum of Ez at the endplate causes strong reflection, which gives a higher low-field peak. Thus, the short tube is better even though a lot of useless ionization occurs near the endplate. This shows that computing Ez may be the best way to fit the tube length to the half-wavelength of the helicon wave and optimize the loading.

Page 20: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Magnet design

This is the external field of NdFeB ring magnets 3” ID x 5” OD x t” thick. The 2” magnet can be made by stacking two 1” magnets. The rectangle shows where the 1.5” long discharge tube can be placed to have ~140G at the antenna. The upper left corner of the rectangle shows the B-field at the endplate. The position z is measured from the midplane of the magnet.

0

100

200

300

400

500

0 5 10 15 20 25 30z (cm)

B (

G)

t = 4"

t = 3"

t = 2"

t = 1"

Page 21: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

R, L

R, L

R, L

R, L

PS

N loadsLs - short

cables

Distributor

Z1

Z2

L - long cable

C1C2

Matching ckt.

Z0

Match circuit design

We calculate the values of C1 and C2 to make sure they are reasonable.Except for the parameter that is being varied, we assume;

f = 27.12 MHzL = 0.39 uH (2-turn antenna); R = 2 N = 4 tubes; matching is easier with more tubes.Z1 = Z2 = 30 cm

Page 22: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

0

200

400

600

800

1000

1200

0.5 1.5 2.5 3.5 4.5R ()

C (

pF)

C1(S)

C2(S)

0

200

400

600

800

1000

1200

0 0.5 1 1.5 2L (uH)

C (

pF)

C1(S)

C2(S)

0

200

400

600

800

1000

0 25 50 75 100 125 150Z2 (cm)

C (

pF)

C1(S)

C2(S)

0

100

200

300

400

500

600

700

800

0 50 100 150 200Z1 (cm)

C (

pF)

C1(S)

C2(S)

This shows insensitivity to R. A 3-turn antenna has L ~ 0.88 H. So a 2-turn antenna should have L ~ 0.88 (2/3)2 ~ 0.39 H. This is within range.

No problem with Z1.The limit for Z2 is OK for 4 tubes. 8

tubes far apart may be a problem.

Page 23: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Increase tube diameter to 3 inches

0.0

0.5

1.0

1.5

2.0

2.5

3.0

1E+10 1E+11 1E+12 1E+13n (cm-3)

R (

oh

ms)

140

120

100

80

60

40

20

B (G)a = 3.8, b = 5.0, c = 30 cmH = 5.1 cm conducting

15 mTorr hydrogen, KTe = 3 eV27.12 MHz, (s,t,fa) = (4,1, 0.3)

0.0

0.5

1.0

1.5

2.0

2.5

3.0

1E+10 1E+11 1E+12 1E+13n (cm-3)

R (

oh

ms) 140

120

100

80

60

40

20

B (G)

a = 3.8, b = 5.0, c = 30 cmH = 7.6 cm conducting

15 mTorr hydrogen, KTe = 3 eV27.12 MHz, (s,t,fa) = (4,1, 0.3)

0

1

2

3

4

5

6

7

-1.00 -0.95 -0.90 -0.85 -0.80z (m)

P(z

) Pz

Ez

3" diam tube, H = 2"100G, 5E11, 27.12, R = 2.51

Here we try a larger tube to get better loading. The scans for H = 3” do not look good, but at H = 2”, there is a good peak at 100G and n = 5 x 1011 cm-3, where R = 2.5. The profiles for this case show a large Ez at the endplate, but the minimum is at the antenna. Therefore, the constructive interference occurs downstream, and Pz maximizes outside the tube.

Page 24: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

0

50

100

150

200

250

300

0 5 10 15 20 25 30z (cm)

B (

G)

1 magnet 4" ID, 6" OD, 2" thick

2" long tube, 100G at antenna

Magnet for 3-in. diam tube

Page 25: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

0

200

400

600

800

1000

1200

0 0.5 1 1.5 2L (uH)

C (

pF)

C1(S)

C2(S)

Matching of 2-turn antenna for 3” diam tube

If a 3-turn, 2” diam antenna has L = 0.88H, a 2-turn, 3” diam antenna has L = (0.88)(2/3)2(3/2)=0.59 H. This is within the range of this diagram for 4 tubes, the same as shown before.

Page 26: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

HYDROGEN HELICONS

Part 1: Preliminary considerations

Part 2: Design for high density

Part 3: Design for low density

Francis F. Chen, UCLA, October, 2008

Page 27: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Design of helicon system for low-density hydrogen operation

1. Since hydrogen is harder to ionize, competing systems probably run at lower density than in argon.

2. We therefore assume n = 2 x 1011 cm-3 and try to optimize the system for that density. The density at the substrate will be in the mid 1010 range.

3. RF frequency assumed to be 27.12 MHz

4. H is the distance between the antenna midplane and the conducting endplate. Insulating endplate is not as good.

5. Assumed 15 mTorr, KTe = 3 eV, n(r) given by s = 4, t = 1, fa = 0.3.

Francis F. Chen, UCLA, October, 2008

Page 28: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

What can we vary?

z

nk

k B

We wish to lower n from our previous optimum, but we don’t want to increase f beyond 27.12 MHz because power supplies are harder to get, and lumped-circuit matching may not be possible. Also, we don’t want to decrease B because of lower coupling efficiency.

We can decrease k by increasing the tube diameter, and decrease

kz by increasing H. To lower n by an order of magnitude from

2E12 to 2E11, we can try to increase a from 2” to 6” and H from 2” to 6”. We shall find that the best solution is not quite that.

Page 29: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Try to optimize constructive interference

From now on, we assume a 6” tube diameter. Here, all cases seem good, with a deep minimum showing good reflection and maxima at the two ends of the tube.

0

1

2

3

4

5

6

7

8

9

-1.00 -0.95 -0.90 -0.85 -0.80z (m)

P(z

), E

z

Pz

|Ez|

R = 3.95 H = 5.5"

0

1

2

3

4

5

6

7

8

9

-1.00 -0.95 -0.90 -0.85 -0.80z (m)

P(z

), E

z

Pz

|Ez|

R = 3.76 H = 6.5"

0

1

2

3

4

5

6

7

8

9

-1.00 -0.95 -0.90 -0.85 -0.80z (m)

P(z

), E

z

Pz

|Ez|

R = 3.68 H = 6"

Page 30: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Scan for low-field peak for various tube lengths

Here we try to get a peak at n = 2E11. Three possibilities are H = 3” @ 100G, H = 4.5” @ 140G, and H = 7” @ 70G. R is much higher than in last slide.

0

1

2

3

4

5

6

7

8

9

1E+11 1E+12n (cm-3)

R (

oh

ms)

140

120

100

80

B (G)

Hydrogen, 27.12 MHz, 6" diam, H = 3"

0

1

2

3

4

5

6

7

8

9

1E+11 1E+12n (cm-3)

R (

oh

ms)

140

120

100

80

B (G)

Hydrogen, 27.12 MHz, 6" diam, H = 4.5"

0

1

2

3

4

5

6

7

8

9

1E+11 1E+12n (cm-3)

R (

oh

ms)

140

120

100

80

B (G)

Hydrogen, 27.12 MHz, 6" diam, H = 6"

0

1

2

3

4

5

6

7

1E+11 1E+12n (cm-3)

R (

oh

ms)

140

120

100

80

70

60

B (G)

Hydrogen, 27.12 MHz, 6" diam, H = 7"

Page 31: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Axial profiles for the three best cases @ 2x1011 cm-3

The best loading (R > 7) occurs when the wave profiles do not show large maxima and minima. The 7” long tube has good resonances, but R < 5

The surprising result is that a short tube with H = 3” at 100G is best because it requires a relatively low field.

0

4

8

12

16

-1 -0.95 -0.9 -0.85 -0.8z (m)

Pz,

Ez

Pz

|Ez|

100G, H = 3", 27.12, 2e11

R = 7.3

0

4

8

12

16

-1 -0.95 -0.9 -0.85 -0.8z (m)

Pz,

Ez Pz

|Ez|

140G, H = 4.5", 27.12, 2e11

13.56 MHz

R = 7.96

0

4

8

12

16

-1 -0.9 -0.8 -0.7z (m)

Pz,

Ez

Pz

|Ez|

Pz

|Ez|

H = 7", 27.12

140G

70G

R = 4.5

R = 4.8

Page 32: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Magnet design

This is the external field of NdFeB ring magnets 7” ID x 10” OD x t” thick. The large rectangle shows where the 4.5” long tube can be placed to have ~140G at the antenna for t = 6”. The smaller rectangle is for a 3” tube, 100G, and t = 4”. The horizontal line is for a 7” tube, 70G, and t = 3”. Only the 3” tube is practical.

0

50

100

150

200

250

300

0 5 10 15 20 25 30 35 40z (cm)

B (

G)

t = 6"

t = 4"

t = 3"

t = 2"

H = 4.5", B = 140G

H = 3", B = 100G

Page 33: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

R, L

R, L

R, L

R, L

PS

N loadsLs - short

cables

Distributor

Z1

Z2

L - long cable

C1C2

Matching ckt.

Z0

Match circuit design

We calculate the values of C1 and C2 to make sure they are reasonable.Except for the parameter that is being varied, we assume;

f = 27.12 MHzL = 0.29 uH (1-turn antenna); R = 6 N = 4 tubes; matching is easier with more tubes.Z1 = Z2 = 30 cm

Page 34: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Antenna and match circuit design

0

100

200

300

400

500

0 50 100 150 200Z1 (cm)

C (

pF)

C1(S)

C2(S)

0

200

400

600

0 25 50 75 100 125 150Z2 (cm)

C (

pF)

C1(S)

C2(S)

0

200

400

600

800

1000

1200

0 0.5 1 1.5 2L (uH)

C (

pF)

C1(S)

C2(S)

0

200

400

600

800

1000

0 2 4 6 8 10R ()

C (

pF)

C1(S)

C2(S)

A 3-turn antenna has L ~ 0.88 H, measured previously. A 2-turn antenna still has too much inductance with a 6” diameter. Hence, we must use a 1-turn antenna with inductance 0.29 H, which is 0.88*3/32. These curves are for 4 tubes and 27.12 MHz.

Page 35: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Voltage and current in one antenna

The voltage and current to each antenna can be large before breakdown, when Rp = 0 and R = Rc ~ 0.5Here are the values for 400W applied to a single antenna.

0

500

1000

1500

2000

0 2 4 6 8 10R ()

Vp

ea

k

0

5

10

15

20

25

30

Irms (A

)

Vpeak

Irms

L = 0.29 uH, 27.12 MHz, Prf = 400W

Page 36: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Comparison of 3 optimized systems of different diameters

For hydrogen at 27.12 MHz

Tube: 2” diam, 1.5” highMagnet: 3 x 5”, 2” high

Tube: 3” diam, 2” highMagnet: 4 x 6”, 2” high

Tube: 6” diam, 3” highMagnet: 7 x 10”, 4” high

Page 37: HYDROGEN HELICONS Part 1: Preliminary considerations Part 2: Design for high density Part 3: Design for low density Francis F. Chen, UCLA, October, 2008.

Conclusion The six-inch diameter system is too large to be practical. In addition to the larger magnets required, the distance between the sources and the substrate has to be increased to achieve plasma uniformity. At low densities helicon discharges have no advantage over ICPs*.

If densities higher than in ICPs are useful, then the Medusa system with either 2-in. or 3-in diameters can be designed to give good performance. The 2-in. system is easiest to make and is more compact, but the 3-in. system has higher plasma resistance and is more likely to make the circuit losses negligible.

0.0

0.1

0.2

0.3

0.4

1E+10 1E+11 1E+12n (cm-3)

R (o

hms)

* However, this HELIC calculation at 1G (B = 0 would diverge) for the Medusa 2 tube and antenna shows very poor plasma resistance at 27.12 MHz in hydrogen.