Hycal Energy Resolution - Purpose

• In order to achieve proper estimation of systematic errors, as well as producing the most accurate simulation models, the energy resolution of the calorimeter were determined for each module.

Page 3: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Hycal Energy Resolution – Data Collection

• Data was acquired during “snake scans,” dry-runs for the purpose of calibrating and testing calorimeter.

• The calorimeter is constituted by two types of detectors, lead glass and lead tungstate (PbWO4).

• The snake scans were done with an incident photon beam of energies between 1 GeV and 5.5 GeV, which were categorized into “energy bins” between 1 and 15.

Page 4: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Hycal Energy Resolution – Data Analysis

• Histograms were made for the ratio of energy defined by Hycal and by Tagger (which has ~0.1% energy resolution).

• After all histograms had been properly fit with a Gaussian, parameters of the fits were extracted, i.e. amplitude, mean, and sigma (along w/ errors).

•These parameters were separately gathered, and graphed for each channel, as a function of energy.

Page 5: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Hycal Energy Resolution – Data Analysis

• These graphed parameters were fit with the function:

• A represents constant term of energy resolution, B represents energy fluctuations (“stochastic” term), and C represents electronic noise.

• E represents beam energy

E

C

E

BA

Page 6: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Hycal Energy Resolution – Data Analysis

• Parameter C was fixed, parameters A and B were extracted and graphed.

• Channels with ID less than 1000 were lead glass, and channels with ID 1000 and up were tungstate. These channels were separated for a more precise result.

Page 7: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Hycal Energy Resolution – Data Analysis

• Parameter B was altered by roc-4 modules, which experienced higher than average distortion.

• Shown Below is a diagram of roc-4 in Hycal.

Page 8: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Hycal Energy Resolution – Final Analysis

• Hycal Resolution was extracted by looking at all sigma values for one energy bin.

• Shown right are the results from the two snake scans, both using energy bin 14 (~5GeV).

• Resolution seems to hover around 1.65-1.8% (for crystal channels).

Page 9: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Timing - Purpose

• To more properly understand Hycal timing in triggers.

• This data will be used in timing alignment and simulation processing.

Page 10: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Timing – Data Processing

• Along with resolution information, timing data was also extracted.

• Thankfully, there were many fewer histograms dealing with timing. This allowed for faster processing.

Page 11: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Timing – Data Analysis• Much like

resolution analysis, these histograms were fitted with a Gaussian, and had fit parameters stored for further analysis.

• Time Difference refers to the time between a beam trigger and a Hycal trigger

Page 12: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Timing – Data Analysis• A problem was

encountered with the first snake scan. The top graph shown right has duel peaks – indicating two signals. This issue only arose for lead glass channels.

• The lower graph is from the same channel in the second snake scan. Clearly this issue was not present during that run

• The error was attributed to a broken or loose cable in the detector, causing a kind of internal reflection. These results were excluded in the final analysis.

Page 13: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Timing – Final Analysis• Fit parameters were

gathered into one histogram, both for collective mean and sigma.

• Shown right top are mean values for first snake, and right bottom are mean values from second snake

Page 14: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Trigger Efficiency - Purpose

• Before this study, a detailed examination of trigger efficiency was lacking. This information will be used to see how close efficiency is to 100%. This will be used in π0 lifetime error budget.

• This is the first study done on trigger efficiency, more important data analysis needing to be done beforehand.

Page 15: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Trigger Efficiency – Data Processing

• Along with resolution and timing, efficiency data was extracted from snake scan data.

• However, for efficiency, analysis was only done one the first snake scan.

• First, data were selected with a proper beam trigger and energy deposition in Hycal. Then event count in sample were checked, followed by checking if sample had a Hycal trigger (trigger bit2).

Page 16: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Trigger Efficiency – Data Analysis

• To say it more accurately, what as analyzed was trigger miss efficiency, i.e. trigger miss rate.

Page 17: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Trigger Efficiency – Data Analysis

• Channels in the highlighted box shown (bottom right) were disconnected during the scan, and yielded nearly 0% efficiency.

• Since then, this hardware problem has been corrected.

Page 18: Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.

Trigger Efficiency – Final Analysis• It was discovered that

nearly all channels, in energy bins greater than 10 (>2.8 GeV) , had 100% efficiency.

• Some channels were broken: 12, 732, 900.

• Other channels had bad efficiency due to a dead dinode: 79, 268, 877, and 1849.

• Shown right is a histogram, in logarithmic scale, of all channels (excluding the disconnected block and problem channels mentioned above).