Hybrid Powered

download Hybrid Powered

of 28

Transcript of Hybrid Powered

  • 8/10/2019 Hybrid Powered

    1/28

    HybridPoweredEnvironmental Quality

    Meter

    850068

    Instruction Manual

  • 8/10/2019 Hybrid Powered

    2/28

    - 2 -

    Hybrid-Powered Envi ronm ental Quality Meter 850068

    Copyrig ht 2009 by Sper Scientific

    ALL RIGHTS RESERVED

    Printed in the USA

    7720 E. Redfield Rd. Suite #7, Scottsdale, AZ 85260

    Tel: (480) 948-4448 Fax: (480) 967-8736Web: www.sperscientific.com

    The contents of this manual may not be reproduced ortransmitted in any form or by any means electronic,mechanical, or other means that do not yet exist ormay be developed, including photocopying, recording,or any information storage and retrieval systemwithout the express permission from Sper Scientific.

  • 8/10/2019 Hybrid Powered

    3/28

    - 3 -

    MATERIALS SUPPLIED .................. 4

    INTRODUCTION ................................... 5

    FEATURES .................................... 7

    UNIT DESCRIPTION ...................... 8

    LCD DISPLAY ................................. 9

    KEYPAD ......................................... 10

    POWER TYPE SELECTION ........... 11

    MEASUREMENT PROCEDURES... 12-21

    BATTERY REPLACEMENT ............ 22TROUBLESHOOTING ..................... 23

    ERROR CODES .............................. 23

    SPECIFICATIONS ........................... 24

    OPTIONAL ACCESSORIES ............ 26

    ENVIRONMENT REFERENCES ..... 27

    WARRANTY .................................... 28

    TABLE OF CONTENTS

  • 8/10/2019 Hybrid Powered

    4/28

  • 8/10/2019 Hybrid Powered

    5/28

    - 5 -

    The Sper Scientific Hybrid-Powered

    Environmental Quality Meter 850068 is a 4-in-1 instrument that functions as a:

    Light Meter measures light using anexclusive photodiode and color-correction-filter, light sensor. Meets theCommission Internationale delEclairage (CIE) photopic standards.

    Anemometer measures wind-speedusing a low-friction, ball bearing wheeldesign to provide exceptional accuracy.

    Hygrometer measures relativehumidity using a high-precisionhumidity sensor with fast response

    time.Thermometer measures temperatureusing standard Type-K (NiCr-NiAl)thermocouple input jack for all Type-Kprobes (optionally available).

    INTRODUCTION

  • 8/10/2019 Hybrid Powered

    6/28

  • 8/10/2019 Hybrid Powered

    7/28

    - 7 -

    Multi-Purpose 4-in-1 Meter

    Hybrid-Power (Hand-Crank Generator)

    Rugged, Light-Weight, and Portable

    Accurate and Easy-to-Use

    One-Button Control

    Hold

    Minimum and Maximum Recall

    Multi-Channel Display

    Tripod Mountable

    Data Analysis through PC ConnectionZero Offset Adjustment

    Easy Calibration

    FEATURES

  • 8/10/2019 Hybrid Powered

    8/28

    - 8 -

    UNIT DESCRIPTION

    LightSensor

    Generator Hand-Crank(Bottom of Unit)

    Easel Stand(Back of Unit)

    LCDDisplay

    KeyPad

    Humidity Sensor(Top of Unit)

    Temperature Thermocouple and Anemometer Probe Input Por ts

    (Top of Unit)

    Tripod Screwand Battery

    Compartment(Back of Unit)

    Power TypeSwitch

    (Side of Unit)

  • 8/10/2019 Hybrid Powered

    9/28

    - 9 -

    LCD DISPLAY

    LightLevel Measurement Units

    LuxFt-cdx10

    Both Lux and Ft-cd (Foot Candle)measure luminance.Lux = lumens per square meter.Ft-cd = lumens per square foot .X10 = Value displayed is 1/10 the value.

    Air Veloc ity Measurement Units

    ft/minm/S

    km/hMPHknots

    Feet per minute

    Meters per second

    Kilometers per hourMiles per hour

    Nautical miles per hour

    Relative Humidity Measurement Units

    %Relative humidity (RH) is a term used todescribe the amount of water vapor thatexists in the air and displays as apercentage.

    Temperature Measurement Units

    C/F Represents the temperature in eitherCelsius or Fahrenheit degrees.

    Record Mode and Hold Indicators

    RECMAXMIN

    HOLD

    Meter is operating in Record Mode.Maximum value recorded.

    Minimum value recorded.

    Meter display is in Hold Mode.

  • 8/10/2019 Hybrid Powered

    10/28

    - 10 -

    KEY PAD

    Turns the unit on/off

    Freezes current measurement valueClears recorded min/max values

    Enters Record ModeDisplays recorded min/max values

    Changes unit of measure for an-

    emometerCalibrates the light sensor

    Changes unit of measure for lightmeter and temperature scale

    Selects measurement mode

  • 8/10/2019 Hybrid Powered

    11/28

    - 11 -

    POWER TYPE SELECTION

    Hybrid Power (Green) Selection

    1. Slide the Power Type Switch up to theG position to use the meters Greenpower source instead of battery power.

    The low battery indicator willdisplay in the upper leftcorner of the LCD display.

    2. Lift and extend the generators hand-

    crank located at the bottom of the unit.

    3. Rotate the handle clockwise to windupor crank the generator to create powerfor the meter.

    Cranking the meters generator for 20seconds will offer several minutes ofenergy. Use as needed for efficientGreen-power operation.

  • 8/10/2019 Hybrid Powered

    12/28

    - 12 -

    POWER TYPE SELECTION

    Battery Power Selection

    1. Ensure that you have correctly installedthe 9V battery in the batterycompartment. (Refer to BatteryReplacement page 22).

    2. Slide the Power Type Switch down tothe B position to use the metersbattery power source instead of Greenpower.

    NoteThe battery life is greater than 1000 hourswhen using alkaline batteries (250 hourswhen using general purpose batteries).

    Light-Level Measurement

    1. Press POWER to turn the meter on .

    2. Press FUNCTION until the meterdisplays the Lux or Ft-cd light-levelmeasuring unit.

    3. Press LUX/FT-CD to select betweenLux and Ft-cd.

    4. To ensure measurement accuracy,calibrate the light meter using the Zero-Offset adjustment feature. Tocalibrate:

    MEASUREMENT PROCEDURES

  • 8/10/2019 Hybrid Powered

    13/28

    - 13 -

    MEASUREMENT PROCEDURES

    5. Cover the light sensor to block any light

    from registering on the meter. PressZERO to calibrate the meter to zero.

    The meter displays the light-level valueas 0 and is ready to measure light,even in low-lit and dark areas.

    6. Uncover the light sensor and ensurethat the light sensor on the front of themeter is pointing toward the luminationsubject and is free from obstruction.

    7. The meter measures the light level ofthe surrounding environment anddisplays the reading.

    When measuring intense light, themeter displays x10 to indicate that thevalue displayed is 1/10 the actual value.

  • 8/10/2019 Hybrid Powered

    14/28

    - 14 -

    MEASUREMENT PROCEDURES

    Air-Velocity Measurement

    1. Ensuring correct pin alignment, insertthe Anemometer plug into the PROBEIN Anemometer socket located at thetop of the unit.

    2. Press POWER to turn the meter on .

    3. Continuously press FUNCTION untilthe meter displays the wind-speed andambient temperature measuring units(ft/min, m/S, km/h, MPH, knots, C, F).

    3. Continuously press UNIT to select thedesired wind-speed measuring unit.

    4. Press C/F to select between aCelsius (C ) and Fahrenheit (F )temperature reading.

    5. Hold the Anemometer Vane Probe andensure that the Anemometer VaneProbe Head and air flow sensor is freefrom obstruction.

  • 8/10/2019 Hybrid Powered

    15/28

    - 15 -

    6. Face the air-flow sensor (marked with ayellow dot) in the direction of the wind.

    7. The meter measures the wind-speedand ambient temperature of thesurrounding environment and displaysthe value.

    MEASUREMENT PROCEDURES

  • 8/10/2019 Hybrid Powered

    16/28

    - 16 -

    Relative Humidity Measurement

    1. Press POWER to turn the meter on .

    2. Continuously press FUNCTION untilthe meter displays the relative humidityand ambient temperature measuringunits (%RH, C, F).

    3. Press C/F to select between a

    Celsius (C ) and Fahrenheit (F )temperature reading.

    4. Ensure that the humidity sensor is freefrom obstruction.

    5. The meter measures the relativehumidity and ambient temperature of

    the surrounding environment anddisplays the value.

    Note When moving the meter to a newenvironment, it may take a few minutesfor the humidity readings to stabilize.

    MEASUREMENT PROCEDURES

  • 8/10/2019 Hybrid Powered

    17/28

  • 8/10/2019 Hybrid Powered

    18/28

    - 18 -

    Hold Mode Selection

    1. Press POWER to turn the meter on .

    2. Using the FUNCTION button, selectyour desired measurement function(Light, Air-Velocity, Relative Humidity,or Temperature).

    3. When a value displays that you want to

    retain, press HOLD .The meter freezes the currentmeasurement value and discontinuesmeasurement while in Hold Mode.

    4. Press HOLD again to exit Hold Modeand resume measurement.

    MEASUREMENT PROCEDURES

  • 8/10/2019 Hybrid Powered

    19/28

    - 19 -

    Record Mode & Auto-Off Selection

    To save battery life, the EnvironmentalQuality Meter turns off automatically after10 minutes of inactivity. To override thisfeature:

    1. With the meter turned on , press MAX/MIN. The meter displays REC,disables the Auto-Off feature, entersRecord Mode and begins recordingmaximum and minimum values.

    2. While the meter displays REC andwhen you are ready to view themaximum and/or minimum measuredvalues, press the MAX/MIN button.

    (The MAX/MIN button toggles between

    the maximum and minimum measuredvalues.)

    MEASUREMENT PROCEDURES

  • 8/10/2019 Hybrid Powered

    20/28

    - 20 -

    3. To clear the max/min values andcontinue recording, press HOLD . Themeter clears the previously recordedmax/min values and enters RecordMode.

    4. To exit the Record Mode, press andhold MAX/MIN for 2 seconds.

    The meter exits Record Mode, displaysthe current reading value, and resets toautomatically turn off after 10 minutesof inactivity.

    MEASUREMENT PROCEDURES

  • 8/10/2019 Hybrid Powered

    21/28

    - 21 -

    Hands-Free Operation

    The Environmental Quality Meter includesboth a built-in mini-easel and a tripodscrew-mount for easy hands-freemonitoring.

    Bench-Top (840092) and Field (840093)Tripods are available as optionalaccessories and attach simply via the

    screw-mount located on the back of themeter.

    To use the easel:

    1. Lift up the easels bottom edge andextend out using the easels hinge.

    2. Using the mini-easel, you can stand themeter on any stable surface for hands-free, long-term monitoring.

    3. When finished monitoring, lightlycollapse the easel back into place.

    MEASUREMENT PROCEDURES

  • 8/10/2019 Hybrid Powered

    22/28

    - 22 -

    BATTERY REPLACEMENT

    1. If the meter displays the low batteryicon , press POWER to turn themeter off .

    2. Use a small Philips screwdriver tounscrew the two screws that secure thebattery compartment and remove thecover.

    3. Remove the old batteries and replacewith one DC 9V battery, ensuringcorrect polarity.

    4. Replace the compartment cover and re-secure using the two Philips-headscrews.

    Note

    The battery life is greater than 1000 hourswhen using alkaline batteries (250 hourswhen using general purpose batteries).

  • 8/10/2019 Hybrid Powered

    23/28

    - 23 -

    TROUBLESHOOTING

    No Display:

    Ensure that you have pressed POWER for longer than 100mS.

    Ensure that the batteries are in goodcondition, have proper contact, and arein correct polarity. When in doubt,replace the batteries.

    Display Disappears:

    If the low battery indicator appeared onthe LCD before the displaydisappeared, replace the batteries.

    Disable the Auto-Off function and placethe unit in Record Mode. (Refer to

    Record Mode and Auto-Off Selectionpage 19).

    ERROR CODES

    - - - - Measurement is out-of range.

    Indicates low battery, replacebatteries.

  • 8/10/2019 Hybrid Powered

    24/28

    - 24 -

    SPECIFICATIONS

    General Specifications

    Size 6.7 (H) x 2.8 (W) x 1.5 (D)170mm (H) x 70mm (W) x 39mm (D)

    Weight 15.2 oz. (432g)Excluding Battery

    PowerSupply

    DC 9V battery orGreen-Power (Crank Generator)

    PowerConsumption

    Anemometer: Approx. DC 11 mA.Other functions : Approx. DC 7.5 mA.

    Operating Temp 0 to 50 C (32 to 122 F)

    OperatingHumidity Maximum 80% RH

    Display Size 1.57 (H) x 1.26 (W)40 mm (H) x 32 mm (W)

    Response Time Typically 15 seconds

    Light Meter Specifications

    Unit Range Resolution Accur acy

    Lux 0 ~ 2,000 Lux1800 ~ 20,000 Lux1 Lux10 Lux 5% rdg

    8 dgtFt-cd 0 ~ 204.0 Ft-cd170 ~ 1860 Ft-cd

    0.1 Ft-cd1 Ft-cd

    *rdg (reading), dgt (digital)

  • 8/10/2019 Hybrid Powered

    25/28

    - 25 -

    SPECIFICATIONS

    Anemometer Specificat ions

    Unit Range Resolution Accur acy

    ft/min 80 ~ 4930 ft/min 1 ft/min

    20 m/S3% F.S.

    >20 m/S4% F.S.

    m/S 0.4 ~ 25.0 m/S 0.1 m/S

    km/h 1.4 ~ 90.0 km/h 0.1 km/h

    MPH 0.9 ~ 55.9 MPH 0.1 MPH

    knots 0.8 ~ 48.6 knots 0.1 knots

    * F.S. =Full Scale

    Thermometer & Hygrometer Specifications

    Unit Range Resolutio n Accur acy

    C ( Amb ien t) 0 ~ 50 C 0.1 C 1.2 C

    F ( Amb ien t) 32 ~ 122 F 0.1 F 2.5 F

    C (Type-K) -100 ~ 1300 C 0.1 C

    (1% rdg+ 1 C)

    F(Type-K) -148 ~ 2372 F 0.1 F

    1% rdg+ 2 F

    %RH 10 ~ 95% RH 0.1% RH

  • 8/10/2019 Hybrid Powered

    26/28

    - 26 -

    800060~77 Type-K ThermocoupleProbes

    840090 Water-Resistant Case

    840092 Bench-Top Tripod

    840093 Field Tripod

    OPTIONAL ACCESSORIES

  • 8/10/2019 Hybrid Powered

    27/28

    - 27 -

    ENVIRONMENT REFERENCES

    Refer to any of the following organizationsfor current and reliable data regarding

    recommended exposure limits for thevarious elements.

    American Conference of GovernmentalIndustrial Hygienists (www-acgih.org).

    American Industrial Hygiene Association (www.aiha.org).

    Canadian Centre for OccupationalHealth & Safety (www.ccohs.ca).

    Commission Internationale delEclairage (www.cie.co.at).

    Environmental Protection Agency(www.epa.gov).

    International ElectrotechnicalCommission (www.iec.ch).

    International Organization forStandardization (www.iso.org).

    National Climatic Data Center

    (www.ncdc.noaa.gov).

    National Institute for OccupationalSafety and Health (www.cdc.gov/niosh).

    US Occupational Safety and Health Administration (www.osha.gov).

  • 8/10/2019 Hybrid Powered

    28/28

    - 28 -

    Rev. 5/3/2012

    WARRANTY

    Sper Scientific warrants this productagainst defects in materials andworkmanship for five (5) years from thedate of purchase and agrees to repair orreplace any defective unit without charge.If your model has since beendiscontinued, an equivalent Sper Scientificproduct will be substituted, if available.This warranty does not cover damageresulting from accident, misuse, or abuseof the product. To obtain warranty service,ship the unit postage prepaid to:

    SPER SCIENTIFIC LTD.7720 E. Redfield Rd, Suite 7,

    Scottsdale, AZ 85260Email: [email protected]

    Be sure to include a description of theproblem and your return address. Registeryour product online atwww.sperscientific.com or return yourwarranty card within 10 days.