HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency...

14
HP WH SERIES HEAT PUMP WATER HEATER 200l 300l HP200M1, HP250M1 / HP200M3, HP250M3, HP250M3C / HP200S1, HP300S1

Transcript of HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency...

Page 1: HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency class A+ A+ Annual energy consumption (L), kWh 852 845 Capacity, l 195 246 Refrigerant

HP WH SERIES

HEAT PUMP WATER HEATER 200l – 300l

HP200M1, HP250M1 / HP200M3, HP250M3, HP250M3C /

HP200S1, HP300S1

Page 2: HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency class A+ A+ Annual energy consumption (L), kWh 852 845 Capacity, l 195 246 Refrigerant

MAIN ADVANTAGES

Plug & play, easy to install

Trendsetting

Low upfront costs will deliver energy cost savings

Replace the water tank of aging systems for

running cost savings

Compatible with many other energy sources

Page 3: HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency class A+ A+ Annual energy consumption (L), kWh 852 845 Capacity, l 195 246 Refrigerant

TECHNICAL BENEFITS

HPWH-Compressor

Special designed for heat

pumps to maximum the

efficiency

Bottom Boost Condenser

Extra bottom condenser enlarge

the total heat exchange area to

deliver more hot water and

contributes to better efficiency

Micro-Channel Condenser

The micro-channel condenser

has larger contact surface for

better heat transfer performance

and less refrigerant consumption

Condenser Micro-Channel VS. Coil Pipe

Page 4: HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency class A+ A+ Annual energy consumption (L), kWh 852 845 Capacity, l 195 246 Refrigerant

CONTROL SYSTEM

Control panel

5“ LED display with touch control

4 resp. 5 working modes

AUTO mode

Heat pump work in priority and electric heater work as backup to

deliver hot water in pre-set temperature

ECO mode

Heat pump use the off-peak electricity to minimize the expenses

ECO+ mode (S series only)

Both heat pump and electric heater only work under off peak condition

BOOST mode

Heat pump and electric heater start up at same time to deliver hot

water as fast as possible

VACATION mode

Stop working during vacation then back to AUTO mode

just one day before user back from vacation

Page 5: HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency class A+ A+ Annual energy consumption (L), kWh 852 845 Capacity, l 195 246 Refrigerant

M-SERIES

Explosive view Operating modes

(external, exhaust and ambient air)

M3

M3

M1 / M3

Page 6: HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency class A+ A+ Annual energy consumption (L), kWh 852 845 Capacity, l 195 246 Refrigerant

M-SERIES – features

COMFORT

Working modes: Auto / Eco / Boost / Vacation

Additional heating element

Timer control Off Peak Power settings

Hot water volume and temperature display

EFFICIENCY & ENERGY SAVING

COP (A15 / EN16147) = 3,25 (M3)

Working temperature: -5°C (M3)

Micro-Chanel condenser

QUALITY

Magnesium anode protection

Titanium enamel steel tank

50mm PUF insulation

DESIGN

LED display with touch control

Off peak power

Additional energy source connection (M3 only)

Page 7: HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency class A+ A+ Annual energy consumption (L), kWh 852 845 Capacity, l 195 246 Refrigerant

SOLAR CONCEPT

Solar heat pump system (M3)

Combine the HP with a solar collector to

increase the share of renewable energy

Solar priority to save as much energy as

possible

Reduces electricity consumption

No additional solar tank is needed

Easy connection with preinstalled tube-

bundle heat exchanger of 1 m³

Preinstalled connections for temperature

sensor pockets

Page 8: HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency class A+ A+ Annual energy consumption (L), kWh 852 845 Capacity, l 195 246 Refrigerant

M1 SERIES – specifications

Model HP200M1 HP250M1

Efficiency class A+ A+

Annual energy consumption (L), kWh 852 845

Capacity, l 195 246

Refrigerant R134a R134a

COP (A15 / EN16147) 2,90 2,90

Sound power, dB(A) 60 60

Temp range (heat source), ℃ 7..35 7..35

Power input (heat pump only), W 650 650

Heating up time 7℃, h:mm / /

Heating up time 15℃, h:mm 4:30 5:50

Electric backup, W 2150 2150

Extra heat exchanger No No

Loading (QTY. 40HQ), units 51 51

dimensions [mm]

A B C D

HP200M1 629 265 994 1670

HP250M1 629 265 1302 1965

Page 9: HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency class A+ A+ Annual energy consumption (L), kWh 852 845 Capacity, l 195 246 Refrigerant

M3 SERIES – specifications

Model HP200M3 HP250M3 HP250M3C

Efficiency class A+ A+ A+

Annual energy consumption (L), kWh 895 913 906

Capacity, l 195 246 240

Refrigerant R134a R134a R134a

COP (A7 / EN16147) 2,85 2,85 2,85

COP (A15 / EN16147) 3,30 3,30 3,30

Sound power, dB(A) 59 59 59

Temp range (heat source), ℃ -5..35 -5..35 -5..35

Power input (heat pump only), W 495 495 495

Heating up time 7℃, h:mm 6:12 8:12 8:00

Heating up time 15℃, h:mm 4:40 6:21 6:21

Electric backup, W 1500 1500 1500

Extra heat exchanger No No Solar or

boiler

Loading (QTY. 40HQ), units 51 51 51

dimensions [mm]

A B C D E F

HP200M3 629 270 980 1692 180

HP250M3 629 270 1275 1987 180

HP250M3C 629 270 1275 1987 590 180

Page 10: HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency class A+ A+ Annual energy consumption (L), kWh 852 845 Capacity, l 195 246 Refrigerant

S-SERIES

EXPLOSIVE VIEW OPERATING MODE

Page 11: HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency class A+ A+ Annual energy consumption (L), kWh 852 845 Capacity, l 195 246 Refrigerant

S-SERIES – features

COMFORT

5 Working modes: Auto / Eco / Eco+ / Boost / Vacation

Low noise (external unit)

Additional heating element

Signal control or Timer control Off Peak Power settings

Temperature and hot water volume display

EFFICIENCY & ENERGY SAVING

COP (A7, EN16147) = 3,20

Working temperature: -7°C..45°C

Micro-Chanel condenser

QUALITY

Magnesium anode protection

Titanium enamel steel tank

50mm PUF insulation

DESIGN

Flexible installing options with long distance

between external unit and storage of 20 m

LED display with touch control

Off peak power mode

Page 12: HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency class A+ A+ Annual energy consumption (L), kWh 852 845 Capacity, l 195 246 Refrigerant

S1 SERIES – specifications

Model HP200S1 HP300S1

Efficiency class A+ A+

Annual energy consumption, kWh 804 (L) 1304 (XL)

Capacity, l 195 293

Refrigerant R134a R134a

COP (A7 / EN16147) 3,09 3,20

COP (A15 / EN16147) 3,70 4,30

Sound power, dB(A) 64 64

Temp range (heat source), ℃ -7..45 -7..45

Power input (heat pump only), W 665 885

Heating up time 7℃, h:mm 4:08 4:48

Heating up time 15℃, h:mm 3:26 3:58

Electric backup, W 2150 2150

Extra heat exchanger No No

Loading QTY. 40HQ 60 units 51 units

dimensions [mm]

A B C D E F G H

HP200S1 542 272 311 411 1530 1765 681 844

HP300S1 630 281 320 420 1519 1795 681 844

Page 13: HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency class A+ A+ Annual energy consumption (L), kWh 852 845 Capacity, l 195 246 Refrigerant

TECHNICAL DATA

Model HP200M1 HP250M1 HP200M3 HP250M3 HP250M3C HP200S1 HP300S1

Efficiency class A+ A+ A+ A+ A+ A+ A+

Annual energy consumption, kWh

852 845 895 913 906 804 1304

Capacity, l 195 246 195 246 240 195 293

COP (A7 / EN16147) / / 2,8 2,81 2,82 3,09 3,20

COP (A15 / EN16147) 2,90 2,90 3,25 3,2 3,22 3,70 4,30

Sound power, dB(A) 60 60 59 59 59 64 64

Temp. (heat source), ℃ 7..35 7..35 -5..35 -5..35 -5..35 -7..45 -7..45

Average input (HP only), W 650 650 495 495 495 665 850

Heating up time 7℃, h:mm / / 6:12 8:12 8:00 4:08 4:48

Heating up time 15℃, h:mm 4:30 5:50 4:40 6:21 6:21 3:26 3:56

Electric backup, W 2150 2150 1500 1500 1500 2150 2150

Extra heat exchanger No No No No Yes No No

M1 M3 S1 Monobloc

Ambient Air Monobloc

External Air

Split

External Air

Page 14: HP WH SERIES HEAT PUMP WATER HEATERM1 SERIES – specifications Model HP200M1 HP250M1 Efficiency class A+ A+ Annual energy consumption (L), kWh 852 845 Capacity, l 195 246 Refrigerant

THANK YOU FOR YOUR ATTENTION

GREENoneTEC Solarindustrie GmbH

Industriepark St. Veit, Energieplatz 1

9300 St. Veit/Glan

[email protected]

www.greenonetec.com