HP StorageWorks 2012sa Modular Smart Array user guide Part number: 488320-002 Second edition: July 2008

Transcript of HP StorageWorks 2012sa Modular Smart Array user...

Page 1: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

HP StorageWorks

2012sa Modular Smart Array

user guide

Part number: 488320-002Second edition: July 2008

Page 2: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Legal and notice information

© Copyright 2008 Hewlett-Packard Development Company, L.P.

Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.

This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Hewlett-Packard. The information is provided “as is” without warranty of any kind and is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation.

Page 3: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

3

Contents

About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Rack Stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

HP Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Customer Self Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Product Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Subscription Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

HP Websites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Documentation Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

1. System Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

System Management Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

HP StorageWorks MSA2000 Family Storage Management Utility (SMU) . . . . 12

Command-Line Interface (CLI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Hardware Components and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Controller Enclosure Components and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Drive Enclosure Components and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

2. Installing and Cabling Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Site Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Required Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Page 4: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

4 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Installation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Installing Enclosures Into a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Preparing the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Assembling and Installing the Rackmount Bracket Kit . . . . . . . . . . . . . . . . . . . 28

Attaching the Ear Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Connecting Controller and Drive Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Connecting AC Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Testing the Enclosure Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

General Practice for Powering the System Off and On . . . . . . . . . . . . . . . . . . . 37

Obtaining IP Values for Your Storage System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Correcting Enclosure IDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

3. Connecting Hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Host System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Installing the MSA2000 Family SES Driver for Microsoft Windows Hosts . . . 40

Connecting the Enclosure to Data Hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Connecting Remote Management Hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

4. Configuring a System for the First Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Setting Management Port IP Addresses Using the CLI . . . . . . . . . . . . . . . . . . . . . . 42

Configuring Your Web Browser for SMU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

Logging in to SMU from a Local Management Host . . . . . . . . . . . . . . . . . . . . . . . . 46

Updating Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Selecting an Appropriate Time to Perform the Online Upgrade . . . . . . . . . . . . 47

Setting the Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Creating Virtual Disks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Mapping a Volume to a Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

Testing the Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

Logging Out of SMU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Page 5: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Contents 5

5. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Fault Isolation Methodology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Gather Fault Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Determine Where the Fault Is Occurring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

Review the Event Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Isolate the Fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Correcting Enclosure IDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

Using System LEDs to Diagnose Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Is the front panel Fault ID amber? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Is the controller back panel OK LED off? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

Is the controller back panel Fault/Service Required LED amber? . . . . . . . . . . . 57

Are both drive module LEDs, Online/Activity, and Fault/UID LEDs off? . . . . 57

Is the drive module Fault/UID led blinking amber? . . . . . . . . . . . . . . . . . . . . . 58

Is a connected port’s Host Link Status LED off? . . . . . . . . . . . . . . . . . . . . . . . . 59

Is a connected port’s Expansion Port status LED off? . . . . . . . . . . . . . . . . . . . . 59

Is a connected port’s Ethernet link status LED off? . . . . . . . . . . . . . . . . . . . . . . 60

Is the power-and-cooling module AC Power Good LED off? . . . . . . . . . . . . . . 60

Is the power-and-cooling module DC Voltage/Fan Fault/Service Required LED

amber? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61

Is the drive enclosure back panel OK LED off? . . . . . . . . . . . . . . . . . . . . . . . . 61

Is the drive enclosure Fault/Service Required LED amber? . . . . . . . . . . . . . . . 62

Isolating a Host-Side Connection Fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Isolating a Controller Module Expansion Port Connection Fault . . . . . . . . . . . . . . . 64

Resolving Voltage and Temperature Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

Sensor Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

Power Supply Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

Cooling Fan Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

Temperature Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

Power-and-Cooling Module Voltage Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . 69

Page 6: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

6 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

A. Environmental Requirements and Specifications . . . . . . . . . . . . . . . . . . . . . . . . 71

B. Regulatory Compliance and Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97

Page 7: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

7

About This Guide

Intended Audience

This guide is intended for use by system administrators and information

professionals who are experienced with the following:

n Direct attach storage (DAS) or storage area network (SAN) management

n Network administration

n Network installation

n Storage system installation and configuration, including installing an HP rack

Prerequisites

Prerequisites for installing and configuring this product include familiarity with:

n Servers and computer networks

n Host communications protocols, such as serial-attached SCSI (SAS) and Ethernet

Page 8: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

8 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Document Conventions

Rack Stability

Caution – To reduce the risk of personal injury or damage to the equipment:

n Extend leveling jacks to the floor.

n Ensure that the full weight of the rack rests on the leveling jacks.

n Install stabilizing feet on the rack.

n In multiple-rack installations, secure racks together.

n Extend only one rack component at a time. Racks may become unstable if more

than one component is extended.

Typeface Meaning Examples

AaBbCc123 Book title, new term, or

emphasized word

See the user guide.

A virtual disk (vdisk) can ....

You must ...

AaBbCc123 Directory or file name,

value, command, or

on-screen output

The default file name is store.logs.

.The default user name is manage

Type exit

AaBbCc123 Text you type, contrasted

with on-screen output

# set passwordEnter new password:

AaBbCc123 Variable text you replace

with an actual value

Use the format user@domain.

Page 9: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

About This Guide 9

HP Technical Support

Telephone numbers for worldwide technical support are listed on the HP support

website: http://www.hp.com/support/.

Collect the following information before calling:

n Technical support registration number (if applicable)

n Product serial numbers

n Product model names and numbers

n Applicable error messages

n Operating system type and revision level

n Detailed, specific questions

For continuous quality improvement, calls may be recorded or monitored.

Customer Self Repair

HP customer self repair (CSR) programs allow you to repair your HP StorageWorks

product. If a CSR part needs replacing, HP ships the part directly to you so that you

can install it at your convenience. Some parts do not qualify for CSR. Your HP-

authorized service provider will determine whether a repair can be accomplished by

CSR.

For more information about CSR, contact your local service provider. For North

America, see the CSR website:

http://www.hp.com/go/selfrepair

Product Warranties

For information about HP StorageWorks product warranties, see the warranty

information website:

http://www.hp.com/go/storagewarranty

Page 10: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

10 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Subscription Service

HP strongly recommends that customers sign up online using the Subscriber's

choice website: http://www.hp.com/go/e-updates.

Subscribing to this service provides you with e-mail updates on the latest product

enhancements, newest versions of drivers, and firmware documentation updates as

well as instant access to numerous other product resources.

HP Websites

For other product information, see the following HP websites:

n http://www.hp.com n http://www.hp.com/go/storagen http://www.hp.com/service_locatorn http://www.hp.com/support/manuals n http://www.hp.com/support/downloads

Documentation Feedback

HP welcomes your feedback.

To make comments and suggestions about product documentation, please send a

message to [email protected]. All submissions become the

property of HP.

Page 11: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

11

CHAPTER 1

System Components

The MSA2000 Family 2012sa Modular Smart Array and MSA2000 Drive Enclosure

are high-performance storage solutions that combine outstanding performance with

high reliability, availability, flexibility, and manageability.

Supported configurations include a controller enclosure with or without attached

drive enclosures. A controller enclosure can contain two controllers that interact and

provide failover capability for the data path. The controller enclosure can use SATA

or SAS disk drive modules.

This chapter provides information about the system components, and includes the

following topics:

n “System Management Software” on page 12

n “Hardware Components and LEDs” on page 13

Page 12: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

12 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

System Management Software

Embedded management software includes a web-browser interface and the

command-line interface described below.

HP StorageWorks MSA2000 Family Storage Management Utility (SMU)

SMU is the primary interface for configuring and managing the system. A web

server resides in each controller module. SMU enables you to manage the system

from a web browser that is properly configured and that can access a controller

module through an Ethernet connection.

Information about using SMU is in its online help and in the reference guide.

Command-Line Interface (CLI)

The embedded CLI enables you to configure and manage the system using

individual commands or command scripts through an out-of-band RS-232 or

Ethernet connection.

Information about using the CLI is in the CLI reference guide.

Page 13: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 1 System Components 13

Hardware Components and LEDs

This section describes the main hardware components of your storage system

enclosures.

Controller Enclosure Components and LEDs

Table 1-1 describes the controller enclosure components.

Table 1-1 Controller Enclosure Components

Description Quantity

Controller (I/O) module 1 or 21

1 Air-management system drive blanks or I/O blanks must fill empty slots to maintain optimum airflow through the chassis.

SAS or SATA drive module 2–12 per enclosure

AC power-and-cooling module 2 per enclosure

3-Gbps, 4-lane SAS host ports (SFF-8088

standard interface)

2 per controller module

3-Gbps, 4-lane SAS expansion port (SFF-

8470 standard interface)

1 per controller module

Ethernet port (RJ-45) 1 per controller module

CLI port (RS-232 micro-DB9) 1 per controller module

Page 14: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

14 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Figure 1-1 shows the LEDs on the front of a controller enclosure.

Figure 1-1 Controller Enclosure LEDs (Front View)

Table 1-2 describes the LEDs on the front of a controller. For information about

troubleshooting the system using LEDs, see “Troubleshooting” on page 53.

Table 1-2 Controller LEDs (Front)

LED ColorOperating State Description

Enclosure ID Green On Shows the enclosure ID, which enables you to correlate an

enclosure with logical views presented by management

software. The enclosure ID for a controller enclosure is zero

(0); the enclosure ID for an attached drive enclosure is

nonzero.

UID

(Unit

Identification)

Blue On Identified.

Off Not identified.

Fault ID Amber Off No fault condition exists.

On Fault condition exists. The event has been acknowledged

but the problem needs attention. Service action is required.

Heartbeat Green On The enclosure is powered on with at least one power and

cooling module operating normally.

Off Both power and cooling modules are off; the system is

powered off.

Drive modules are numbered by column top to bottom: 0–2, 3–5, 6–8, 9–11

Drive module LEDs (top to bottom)Enclosure ID Status LEDs (top to bottom):UIDFault IDHeartbeat

Fault/UIDOnline/activity

Page 15: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 1 System Components 15

Table 1-3 describes the LEDs on the drive module.

Table 1-3 Drive Module LED Combinations (Front)

Online/Activity(green)

Fault/UID(amber/blue) Description

On Off The drive is online, but it is not currently active.

Blinking

irregularly

Off The drive is active and operating normally.

Off Amber, blinking

regularly (1 Hz)

Offline; the drive is not being accessed. A predictive

failure alert may have been received for this device.

Further investigation is required.

On Amber, blinking

regularly (1 Hz)

Online; no activity. A predictive failure alert may have

been received for this device. Further investigation is

required.

Blinking

irregularly

Amber, blinking

regularly (1 Hz)

The drive is active, but a predictive failure alert may

have been received for this drive. Further investigation

is required.

Off Amber, solid Offline; no activity. A critical fault condition has been

identified for this drive.

Off Blue; solid Offline. The drive has been selected by a management

application.

On or blinking Blue; solid The drive is operating normally, and it has been selected

by a management application.

Blinking regularly

(1 Hz)

Off Do not remove the drive. Removing a drive may

terminate the current operation and cause data loss.

The drive is rebuilding.

Off Off Either there is no power, the drive is offline, or the drive

is not configured.

Page 16: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

16 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Figure 1-2 shows the ports and switches at the back of the controller enclosure.

Figure 1-2 Controller Ports and Switches (Back View)

Table 1-4 describes the ports and switches on the back of the controller.

Table 1-4 Controller Ports and Switches (Back)

Location Port/Switch Description

Power-and-

cooling module

Power switch On/Off toggle

Controller

module

Host ports 3-Gbps, 4-lane SAS ports (12 Gbps total) used to connect to data

hosts. Host port 0 and 1 correspond to host channel 0 and 1,

respectively.

Controller

module

Expansion

port

3-Gbps, 4-lane (12 Gbps total) table-routed SAS Out port used to

connect drive enclosures.

Controller

module

Ethernet port 10/100BASE-T Ethernet port used for TCP/IP-based out-of-band

management of the RAID controller. An internal Ethernet device

provides standard 10 Mbit/second and 100 Mbit/second full-duplex

connectivity.

Controller

module

CLI port Micro-DB9 port used to connect the controller enclosure to a local

management host using RS-232 communication for out-of-band

configuration and management.

Controller

module

MUI

(Service) port

3.5-mm jack port used by service personnel only.

Power switch

Host ports Expansion portCLI port Ethernet portMUI (Service) port

Page 17: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 1 System Components 17

Figure 1-3 shows the LEDs at the back of the controller.

Figure 1-3 Controller LEDs (Back View)

Table 1-5 describes the LEDs on the back of the controller. For information about

troubleshooting the system using LEDs, see “Troubleshooting” on page 53.

Table 1-5 Controller LEDs (Back)

Location LED Color State Description

Power-and-

cooling module

AC Power Good Green Off AC power is off or input voltage is below

the minimum threshold.

On AC power is on and input voltage is normal.

Power-and

cooling module

DC Voltage/

Fan Fault/

Service Required

Amber Off DC output voltage is normal.

On DC output voltage is out of range or a fan is

operating below the minimum required

RPM.

Controller

module

Host link status Green Off The port is empty or the link is down.

On The port link is up and connected.

Controller

module

Host link activity Green Off The host port is not connected or the link is

down.

On The host link is up and active.

AC Power Good

Service RequiredDC Voltage/Fan Fault/ Host link status

Host link activity

Unit Locator

OK to Remove Fault/Service Required

OK

Cache status

Host activity

Expansion port status

Ethernet activity

Ethernet link status

Page 18: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

18 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Controller

module

Unit Locator White Off Normal operation.

Blink Physically identifies the controller module.

Controller

module

OK to

Remove

Blue Off The controller module is not prepared for

removal.

On The controller module can be removed.

Controller

module

Fault/Service

Required

Amber On A fault has been detected or a service action

is required.

Blink Indicates a hardware-controlled power up or

a cache flush or restore error.

Controller

module

OK Green Off Controller module is not OK.

On Controller module is operating normally.

Blink System is booting.

Controller

module

Cache status Green Off Cache is clean (contains no unwritten data).

On Cache is dirty (contains unwritten data) and

operation is normal.

Table 1-5 Controller LEDs (Back) (Continued)

Location LED Color State Description

Page 19: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 1 System Components 19

Controller

module

Cache status Green Blink A Compact Flash flush or cache self-refresh

is in progress. Indicates cache activity.

• If the LED is blinking evenly, a cache

flush is in progress. When a controller

module loses power and write cache is

dirty (contains data that has not been

written to disk), the super-capacitor pack

provides backup power to flush (copy)

data from write cache to Compact Flash

memory. When cache flush is complete,

the cache transitions into self-refresh

mode.

• If the LED is blinking slowly, a cache

flush is in progress. In self-refresh mode,

if primary power is restored before the

backup power is depleted (3–30 minutes,

depending on various factors), the system

boots, finds data preserved in cache, and

writes it to disk. This means the system

can be operational within 30 seconds, and

before the typical host I/O timeout of 60

seconds at which point system failure

would cause host-application failure. If

primary power is restored after the backup

power is depleted, the system boots and

restores data to cache from Compact

Flash, which can take about 90 seconds.

Note: The cache flush and self-refresh

mechanism is an important data protection

feature; essentially four copies of user data

are preserved: one in each controller’s cache

and one in each controller’s Compact Flash.

Controller

module

Host activity Green Off The host ports have no I/O activity.

Blink At least one host port has I/O activity.

Controller

module

Ethernet link status Green Off The Ethernet port is not connected or the

link is down.

On The Ethernet link is up.

Table 1-5 Controller LEDs (Back) (Continued)

Location LED Color State Description

Page 20: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

20 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Drive Enclosure Components and LEDs

A drive enclosure can be connected to a controller enclosure or to another drive

enclosure to provide additional disk storage capacity. Table 1-6 describes the drive

enclosure components.

Controller

module

Ethernet activity Green Off The Ethernet link has no I/O activity.

Blink The Ethernet link has I/O activity.

Controller

module

Expansion port

status

Green Off The port is empty or the link is down.

On The port link is up and connected.

Table 1-6 Drive Enclosure Components

Description Quantity

Expansion (I/O) module 1 or 21

1 Air-management system drive blanks or I/O blanks must fill empty slots to maintain optimum airflow through the chassis.

SAS or SATA drive module 2–12 per enclosure

AC power-and-cooling module 2 per enclosure

3-Gbps, 4-lane SAS In port 1 per expansion module

3-Gbps, 4-lane SAS Out port 1 per expansion module

Service port (RS-232 micro-DB9) 1 per expansion module

Table 1-5 Controller LEDs (Back) (Continued)

Location LED Color State Description

Page 21: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 1 System Components 21

The components and LEDs on the front of a drive enclosure are the same as on a

controller enclosure; see Figure 1-1 and Table 1-2.

Figure 1-4 shows the ports and switches at the back of the drive enclosure.

Figure 1-4 Drive Enclosure Ports and Switches (Back View)

Table 1-7 describes the ports and switches on the back of the drive enclosure.

Table 1-7 Drive Enclosure Ports and Switches (Back)

Location Port/Switch Description

Power-and-

cooling module

Power switch On/Off toggle

Expansion

module

SAS In port 3-Gbps, 4-lane (12 Gbps total) subtractive ingress port used to

connect to a controller enclosure.

Expansion

module

SAS Out port 3-Gbps, 4-lane (12 Gbps total) table-routed egress port used to

connect to another drive enclosure.

Expansion

module

Service port Micro-DB9 port used by service personnel only.

Service port SAS Out port

Power switch

SAS In port

Page 22: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

22 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Figure 1-5 shows the LEDs at the back of the drive enclosure.

Figure 1-5 Drive Enclosure LEDs (Back View)

Table 1-8 describes the LEDs on the back of the drive enclosure.

Table 1-8 Drive Enclosure LEDs (Back)

Location LED Color State Description

Power-and-

cooling module

AC Power Good Green Off AC power is off or input voltage is below

the minimum threshold.

On AC power is on and input voltage is normal.

Power -and-

cooling module

DC Voltage/

Fan Fault/

Service Required

Amber Off DC output voltage is normal.

On DC output voltage is out of range or a fan is

operating below the minimum required

RPM.

Expansion

module

SAS In port status Green Off The port is empty or the link is down.

On The port link is up and connected.

Expansion

module

Unit Locator White Off Normal operation.

Blink Physically identifies the expansion module.

Expansion

module

OK to

Remove

Not implemented.

AC Power Good

Service RequiredDC Voltage/Fan Fault/

SAS In port status SAS Out port status

Unit Locator

OK to Remove Fault/Service Required

OK

Page 23: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 1 System Components 23

Expansion

module

Fault/Service

Required

Amber On A fault has been detected or a service action

is required.

Blink Indicates a hardware-controlled power up or

a cache flush or restore error.

Expansion

module

OK Green Off Expansion module is not OK.

On Expansion module is operating normally.

Blink System is booting.

Expansion

module

SAS Out port

status

Green Off The port is empty or the link is down.

On The port link is up and connected.

Table 1-8 Drive Enclosure LEDs (Back) (Continued)

Location LED Color State Description

Page 24: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

24 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Page 25: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

25

CHAPTER 2

Installing and Cabling Enclosures

This chapter describes how to install and cable enclosures. It contains the following

sections:

n “Site Planning” on page 25

n “Required Tools” on page 25

n “Safety Precautions” on page 26

n “Installation Checklist” on page 27

n “Installing Enclosures Into a Rack” on page 28

n “Attaching the Ear Caps” on page 32

n “Connecting Controller and Drive Enclosures” on page 33

n “Connecting AC Power” on page 36

n “Testing the Enclosure Connections” on page 37

n “Obtaining IP Values for Your Storage System” on page 38

n “Correcting Enclosure IDs” on page 38

Site Planning

Make sure that the installation site adheres to all requirements and specifications as

described in “Environmental Requirements and Specifications” on page 71.

Required Tools

The installation procedures in this chapter require the following tools:

n #2 Phillips screwdriver

n Antistatic protection devices

Page 26: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

26 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Safety Precautions

For your protection, observe the following safety precautions when setting up your

equipment:

n Install the system in accordance with the local safety codes and regulations at the

facility site. Follow all cautions and instructions marked on the equipment.

n Ensure that the voltage and frequency of your power source match the voltage

and frequency inscribed on the equipment’s electrical rating label.

n Never push objects of any kind through openings in the equipment. Dangerous

voltages may be present. Conductive foreign objects could produce a short circuit

that could cause fire, electric shock, or damage to your equipment.

Note – Do not make mechanical or electrical modifications to the product. The

vendor is not responsible for the safety or regulatory compliance of a modified

product.

Caution – Two people are needed to lift and move the enclosure. Use care to avoid

injury. An enclosure with all drives installed can weigh 65 pounds (29.5 kilograms).

Caution – Electrostatic discharge can damage sensitive components. Be sure you

are properly grounded before touching a static-sensitive component or assembly.

Page 27: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 2 Installing and Cabling Enclosures 27

Installation Checklist

Table 2-1 outlines the steps required to install the enclosures and initially configure

the system. To ensure a successful installation, perform the tasks in the order they

are presented.

Table 2-1 Installation Checklist

Step Installation Task Where to Find Procedure

1. Prepare the rack for installation. “Preparing the Rack” on page 28

2. Assemble the rackmount bracket kit and install the

controller enclosure and optional drive enclosures in

the rack.

“Assembling and Installing the

Rackmount Bracket Kit” on page 28

3. Attach the ear caps. “Attaching the Ear Caps” on page 32

4. Connect the enclosures. “Connecting Controller and Drive

Enclosures” on page 33

5. Connect the power cords. “Connecting AC Power” on page 36

6. Test the enclosure connections. “Testing the Enclosure Connections” on

page 37

7. Obtain IP values. “Obtaining IP Values for Your Storage

System” on page 38

8. Correct enclosure IDs, if necessary. “Correcting Enclosure IDs” on page 38

9. Install required host software and drivers, including:

• MSA2000 Family MPIO DSM

• MSA2000 Family SES Driver

“Host System Requirements” on page 39

10. Connect the data hosts. “Connecting Hosts” on page 39

11. Connect the management host. “Connecting Remote Management

Hosts” on page 40

12. Perform initial configuration tasks:

• Set management port IP properties on the

controller enclosure

• Verify that controllers and enclosures have the

latest firmware

• Set the date and time on the controller enclosure

• Configure host ports on the controller enclosure

• Create virtual disks and map volumes

• Test the configuration

“Configuring a System for the First

Time” on page 41

Page 28: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

28 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Installing Enclosures Into a Rack

This section describes how to install the enclosures into a standard 19-inch rack

cabinet with a 28 to 36-inch (71.12 to 91.44-cm) depth.

Tip – To help you correctly identify the screws, keep all hardware items in plastic

bags until you are ready to use them.

Preparing the Rack

Before installing enclosures in a rack cabinet, ensure the rack is installed according

to its installation instructions and that the installation complies with local safety

codes.

1. Stabilize the rack as described in its documentation.

2. If the rack has casters, make sure the casters are locked to prevent the rack from

rolling.

3. Remove or open the top front panel and the vented back panel.

Assembling and Installing the Rackmount Bracket Kit

Note – If the rackmount bracket kit you are installing includes assembly

instructions, use them in place of the instructions in this guide.

Page 29: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 2 Installing and Cabling Enclosures 29

Figure 2-1 provides a visual overview of the rackmount kit assembly components

and corresponds to the steps that follow.

Figure 2-1 Overview of Standard 19-Inch EIA Rackmounting Components

#10-32 x 5/8 truss screws

Threaded PEMs (4)

Rear bracket connected to rack #10-32 x 5/8 truss screws

Side bracket

(Step 6)

(Step 5)

(Step 8)

(Step 9)

#8-32 x 3/16 flathead screws

#8-32 x 1/4 panhead screws

Page 30: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

30 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Use the following procedure and refer to Figure 2-1 to install each enclosure into

the rack.

Note – If the rackmount bracket kit you are installing includes assembly

instructions, use them in place of the instructions in this guide.

When positioning an enclosure in the rack, do not block the air vents at the front or

back of the enclosure.

Caution – If you only have one person to perform the installation, remove the

power and cooling modules and drive modules from an enclosure before

installation, and use the optional nylon front support brackets. If possible, position

the enclosure on top of another device or shelf in the rack to hold the enclosure as

you attach the front brackets.

1. Considering your system configuration and weight distribution in the rack,

determine where you will install each enclosure in the rack.

2. Confirm that you have cables of adequate length to connect to hosts and to power

outlets.

3. (Square-cut European-style racks only) Insert the cage nuts in the corresponding

holes on the front and rear of the rack.

4. (Optional-one person installation) Screw the front support nylon brackets into

position on the rack face using #10-32 x 5/8 screws (two per bracket).

These brackets enable one person to easily position and support the front of the

enclosure in the rack during installation.

5. Attach the side brackets to each side of the enclosure using #8-32 x 3/16 flathead

screws (four to eight on each side). The right and left side brackets are identical.

Note – To allow adjustment of the brackets, do not tighten the screws completely

until the enclosure is mounted in the rack.

a. Use the alignment marks (Figure 2-2) stamped into the side brackets to position

the brackets and screws. The alignment marks show depth in inches.

Determine the depth you require and align the rear-most alignment mark on the

side bracket with the rear-most threaded holes on the enclosure. Make sure that

the alignment mark corresponding to the depth you want lines up with both the

top and bottom holes.

Page 31: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 2 Installing and Cabling Enclosures 31

Figure 2-2 Side Bracket With Alignment Marks

b. On one side, insert the first two screws through the side bracket slots above and

below the alignment mark into the rear-most threaded holes in the enclosure.

For example, to mount the enclosure in a 28-inch deep rack, position the side

bracket so that the 28-inch alignment mark is aligned with the rear-most threaded

holes in the enclosure.

c. Insert up to six more screws through the side bracket slots into the other threaded

holes in the side of the enclosure.

d. Repeat Step b and Step c to attach the other side bracket to the enclosure.

6. Attach the rear brackets to the rear vertical posts of the rack using #‘10-32 x 5/8

screws (two per bracket).

7. Lift the enclosure and slide the side brackets into the rear brackets, which are

attached to the rear posts.

Adjust the depth of the side brackets so that the slots nearest the ends of the side

brackets align with the four PEM nuts in the rear brackets.

8. Attach each side bracket to a rear bracket using #8-32 x 1/4 screws (four per

bracket).

9. Ensure that the enclosure is level, and then, secure the mounting ears on the front of

the enclosure to the rack face using #10-32 x 5/8 screws (two per ear).

10. Tighten the screws on the side brackets.

11. If you removed modules from the enclosure, reinsert them.

12. If you attached the optional front support nylon brackets to the rack face, remove

those brackets.

Note – When you finish installing an enclosure, you may have unused screws left

in your rack kit; extra screws are provided in case any are misplaced.

Page 32: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

32 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Attaching the Ear Caps

The plastic ear caps are snap-on parts that require some care when attaching or

removing them. After the enclosure has been installed in the rack cabinet, attach the

ear caps, which are located in a plastic bag included in the controller and drive

enclosure packages.

1. Remove the ear caps from the plastic package.

2. As you attach each ear cap, hold it so that its indent is closest to the chassis.

Figure 2-3 Attaching Ear Caps

3. Apply gentle pressure to snap the caps onto the chassis’ ears.

Indent

Left ear cap

Indent

Right ear cap

Page 33: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 2 Installing and Cabling Enclosures 33

Connecting Controller and Drive Enclosures

Use the supplied SAS cables to connect a controller enclosure to up to three drive

enclosures. Figure 2-4 and Figure 2-5 show the recommended fault-tolerant cabling

patterns. In an enclosure, the upper module is designated A and the lower module is

designated B.

When connecting multiple drive enclosures, use reverse cabling to ensure the

highest level of fault tolerance. For example, Figure 2-5 shows controller A

connected to expansion module 1A, and the chain of connections continuing down.

Controller B is connected to the lower module (B) of the last drive enclosure in the

chain, with connections moving in the opposite direction.

Fault-tolerant cabling is recommended because it enables the controllers to access

remaining drive enclosures if any one drive enclosure fails. However, the system

also supports non-fault-tolerant cabling using the supplied SAS cables.

Figure 2-6 shows non-fault-tolerant cabling between a controller and up to three

drive enclosures.

Note – For clarity, the schematic illustrations of the controllers shown in this

section show only relevant details such as expansion ports. For detailed illustrations

showing all components, see “Hardware Components and LEDs” on page 13.

Figure 2-4 Cabling Connections Between One Controller Enclosure and One Drive Enclosure

In Out

In Out

Controller B

Controller A

1A

1B

Page 34: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

34 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Figure 2-5 Fault-Tolerant Cabling Connections Between One Controller Enclosure and Up to Three Drive Enclosures

In Out

In Out

Controller B

Controller A

1A

1B

2A

2B

3A

3BIn Out

In Out

In Out

In Out

Page 35: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 2 Installing and Cabling Enclosures 35

Figure 2-6 Non-Fault-Tolerant Cabling Connections Between One Controller and Up to Three Drive Enclosures

In Out

In Out

In Out

In Out

In Out

In Out

Controller B

Controller A

1A

1B

2A

2B

3A

3B

Page 36: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

36 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Connecting AC Power

Use this procedure to connect AC power to the enclosures.

1. Verify that both power switches are off.

2. Using the AC power cords, for each enclosure, connect one power-and-cooling

module to one power source in the rack, and the other power-and cooling-module to

a separate power source in the rack.

3. Connect the primary power cords from the rack to separate external power sources.

Power on the system as described in the following section.

Page 37: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 2 Installing and Cabling Enclosures 37

Testing the Enclosure Connections

Use this procedure to power on the newly installed system.

1. Press the power switches at the back of each drive enclosure to the On position.

This ensures that the disks in the enclosures have enough time to completely spin up

before being scanned by the RAID modules in the controller enclosure.

While enclosures power up, their LEDs blink. After the LEDs stop blinking, if no

LEDs on the front and back of the enclosure are amber, the power-on sequence is

complete and no faults have been detected.

For a description of LED behavior and status, see “Hardware Components and

LEDs” on page 13.

2. Press the power switches at the back of the controller enclosure to the On position.

Depending on the number and type of drives in the system, it can take several

minutes for the system to power up.

If the enclosure’s power-on sequence succeeds as described in Step 1, the system is

ready to use.

General Practice for Powering the System Off and On

The system rarely needs to be powered off. You remove power only when you plan

to physically move the system to another location.

Use this procedure when you need to power off the system.

1. Stop all I/O from hosts to the system.

2. Use SMU to shut down both controllers.

Wait until SMU indicates that processing is complete.

3. Press the power switches at the back of the controller enclosure to the Off position.

4. Press the power switches at the back of each drive enclosure to the Off position.

Page 38: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

38 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

When powering on the system, make sure to power up the enclosures and associated

data host in the following order:

1. Drive enclosures first

2. Controller enclosure next

3. Data hosts last (if they are powered down for maintenance purposes)

Obtaining IP Values for Your Storage System

To obtain the IP values for your system:

1. Look in the DCHP server’s address for the two IP addresses assigned to an “HP

StorageWorks MSA2000 Family” storage device.

2. Use a network management utility to discover “HP StorageWorks MSA2000

Family” storage devices on the local LAN through SNMP.

3. Use a ping broadcast to try to identify the device through the host’s ARP table.

If you do not have a DHCP server, you will need to obtain the IP addresses from

your network administrator, and set them using the CLI during initial configuration

(see “Setting Management Port IP Addresses Using the CLI” on page 42).

Correcting Enclosure IDs

When installing a system with drive enclosures attached, the enclosure IDs might

not agree with the physical cabling order. This is because the controller might have

been previously attached to some of the same enclosures and it attempts to preserve

the previous enclosure IDs if possible. To correct this condition, see “Correcting

Enclosure IDs” on page 55.

Page 39: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

39

CHAPTER 3

Connecting Hosts

This chapter describes how to connect data and management hosts to controller

enclosures. It contains the following sections:

n “Host System Requirements” on page 39

n “Connecting the Enclosure to Data Hosts” on page 40

n “Connecting Remote Management Hosts” on page 40

Host System Requirements

Data hosts connected to MSA2000 Family 2012sa Modular Smart Arrays must meet

the following requirements:

n To configure an HBA that is directly attached to controller enclosure host ports,

set the HBA parameters as specified in the MSA QuickSpecs. QuickSpecs can be

found from your HP MSA products page at http://www.hp.com/go/msa.

Select MSA SAN Arrays, and then select your product. The link for QuickSpecs

will be on the right.

n Depending on your system configuration, data host operating systems may

require that multipathing is supported.

If fault tolerance is required, then multipathing software may be required. Host-

based multipath software should be used in any configuration where two logical

paths between the host and nay storage volume may exist at the same time. This

would include most configurations where there are multiple connections to the

host or multiple connections between a switch and the storage.

To obtain the MSA2000 Family MPIO DSM, go to the HP MSA products page at

http://www.hp.com/go/msa. Select MSA SAN Arrays, select your product,

and go to Related products.

n To prevent Microsoft® Windows® data hosts from displaying the Found New

Hardware Wizard when the storage system is discovered, install the MSA2000

Family SCSI Enclosure Services driver. For more information, see “Installing the

MSA2000 Family SES Driver for Microsoft Windows Hosts” on page 40.

Page 40: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

40 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Installing the MSA2000 Family SES Driver for Microsoft Windows Hosts

Installing the MSA2000 Family SCSI Enclosure Services (SES) driver prevents

Microsoft Windows hosts from displaying the Found New Hardware Wizard when

the storage system is discovered.

1. Download MSA2000 Family SCSI Enclosure Services (SES) driver package

msa2000-ses-version.zip from the http://www.hp.com/go/msa. Select MSA

SAN Arrays, select your product, and go to Related products.

2. Extract the package contents to a temporary folder on the host.

3. In that folder, double-click Setup.exe to install the driver.

4. Click Finish.

The driver is installed.

5. Optionally, delete the extracted files and the SES driver package.

Connecting the Enclosure to Data Hosts

Cable connections vary depending on configuration. For a complete list of

supported configurations, go to the MSA2000 product site at

http://www.hp.com/go/msa for the latest MSA2000 Configuration Options

guide. This document is updated whenever newly supported configurations are

added.

Connecting Remote Management Hosts

The management host directly manages systems out-of-band over an Ethernet

network. This section describes how to connect the Ethernet cables to the

management host.

1. Connect an Ethernet cable to the Ethernet management port on each controller.

2. Connect the other end of each Ethernet cable to a network that your management

host can access (preferably on the same subnet).

Page 41: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

41

CHAPTER 4

Configuring a System for the First Time

This chapter describes how to perform first-time configuration on the storage

system using HP StorageWorks MSA2000 Family Storage Management Utility

(SMU), which is the primary interface for configuring and managing the system. It

also describes how to perform basic storage configuration to verify that your system

is working.

This chapter includes the following topics:

n “Setting Management Port IP Addresses Using the CLI” on page 42

n “Configuring Your Web Browser for SMU” on page 46

n “Logging in to SMU from a Local Management Host” on page 46

n “Updating Firmware” on page 47

n “Setting the Date and Time” on page 47

n “Creating Virtual Disks” on page 48

n “Mapping a Volume to a Host” on page 50

n “Testing the Configuration” on page 50

n “Logging Out of SMU” on page 51

For information about additional configuration and management tasks, including

changing the manage user’s password, refer to SMU’s online help or the reference

guide.

Page 42: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

42 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Setting Management Port IP Addresses Using the CLI

Note – If you used DHCP to set the IP addresses, you do not have to set them using

the CLI as described in this section.

Ethernet Management ports on controller module A and controller module B are

configured with the following default values:

n Management Port IP Address: 10.0.0.2 (controller A), 10.0.0.3 (controller B)

n IP Subnet Mask: 255.255.255.0

n Gateway IP Address: 10.0.0.1

If the default IP addresses are not compatible with your network, you must set an IP

address for each management port using the command-line interface (CLI)

embedded in each controller module. The CLI enables you to access the system

using RS-232 communication and terminal emulation software.

Use the CLI commands described in the steps below to set the IP address for the

Ethernet management port on each controller module.

Once new IP addresses are set, you can change them as needed using SMU.

Note – Changing IP settings can cause management hosts to lose access to the

storage system.

1. From your network administrator obtain an IP address, subnet mask, and gateway

address for controller A and controller B.

2. Use the provided micro-DB9 serial cable to connect controller A to a serial port on

a host computer.

Page 43: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 4 Configuring a System for the First Time 43

Your package contents include a micro-DB9-to-DB9 serial cable. If necessary, use a

DB9-to-DB25 adapter (not included) for connecting the serial cable to a DB25

serial port on the host computer.

3. Start and configure a terminal emulator, such as HyperTerminal or VT-100, using

the display settings in Table 4-1 and the connection settings in Table 4-2.

Table 4-1 Terminal Emulator Display Settings

Parameter Value

Terminal Emulation Mode VT-100 or ANSI (for color support)

Font Terminal

Translations None

Columns 80

Table 4-2 Terminal Emulator Connection Settings

Parameter Value

Connector COM1 (typically)

Baud rate (bits/sec) 115,200

Data bits 8

Parity None

Stop bits 1

Flow control None

Page 44: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

44 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

4. In the terminal emulator, connect to controller A.

5. Press Enter to display the CLI prompt (#).

6. At the prompt, type the following command to set the values you obtained in Step 1

for each Ethernet management port, first for controller A and then for controller B:

where:

n address is the IP address of the controller

n netmask is the subnet mask

n gateway is the IP address of the subnet router

n a|b specifies the controller whose network parameters you are setting

For example:

7. Type the following command to verify the new IP addresses:

set network-parameters ip address netmask netmask gateway gateway controller a|b

# set network-parameters ip 192.168.0.10 netmask 255.255.255.0 gateway 192.168.0.1 controller a

# set network-parameters ip 192.168.0.11 netmask 255.255.255.0 gateway 192.168.0.1 controller b

show network-parameters

Page 45: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 4 Configuring a System for the First Time 45

As shown in the following example, network parameters, including the IP address,

gateway address, and subnet mask are displayed for each controller.

8. In the host computer's command window, type the following command to verify

Ethernet connectivity, first for controller A and then for controller B:

If you cannot access your system three minutes after changing the IP address,

your network might require you to restart the management controller using the CLI.

When you restart a management controller, communication with it is temporarily

lost until it successfully restarts.

Type the following command to restart the management controller on both

controllers:

9. After you have verified Ethernet connectivity, disconnect the serial cable and exit

the emulator.

Network Parameters Controller A

--------------------------------

IP Address : 192.168.0.10

Gateway : 192.168.0.1

Subnet Mask : 255.255.0.0

MAC Address : 00:00:FF:D5:01:4D

Addressing Mode : Manual

Network Parameters Controller B

--------------------------------

IP Address : 192.168.0.11

Gateway : 192.168.0.1

Subnet Mask : 255.255.0.0

MAC Address : 00:C0:FF:D5:01:15

Addressing Mode : Manual

ping IP-address

restart mc both

Page 46: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

46 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Configuring Your Web Browser for SMU

Before using SMU to perform remaining steps, ensure that your web browser is

properly configured according to the following guidelines:

n Use one of the following browsers:

n Microsoft Internet Explorer 5.5 or later

n Mozilla Firefox 1.0.7 or later

n Because SMU uses popup windows to indicate the progress of user-requested

tasks, disable any browser features or tools that block popup windows.

n For optimal performance, set your browser to use stored (cached) web pages.

Note – Changing your browser cache setting might affect other sites you visit with

your browser.

n To optimize display, use a color monitor and set its color quality to the highest

setting.

n For Internet Explorer, to ensure you can navigate beyond SMU login page, set

the local-intranet security option to medium or medium-low.

Logging in to SMU from a Local Management Host

To log in to SMU from a local management host:

1. In your web browser’s address field, type the IP address of one of the controller

enclosure’s Ethernet management ports and press Enter.

The SMU Login page is displayed. If the Login page does not display, verify that

you have entered the correct IP address.

2. On the login page, type the default management user name manage and default

password !manage

3. Click Log In.

The Status Summary page is displayed.

Page 47: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 4 Configuring a System for the First Time 47

Updating Firmware

After installing the hardware and powering up the enclosure for the first time, be

sure to verify that the controllers and drive enclosures have the latest firmware.

SMU enables you to view the software, hardware, and other version information for

each controller and the enclosures.

To view controller version information, select Monitor > Status > Advanced

Settings > Controller Versions. To view drive enclosure information, select Manage

> Update Software > Enclosure Firmware > Show Enclosures.

Selecting an Appropriate Time to Perform the Online Upgrade

To ensure the success of an line upgrade, selecting the appropriate time is essential.

Selecting a period of low I/O activity will ensure the upgrade completes as quickly

as possible, and will avoid disruptions to host and applications due to timeouts.

Attempting to upgrade a storage system that is in the middle of processing a large

I/O intensive batch job will likely cause hosts to lost connectivity with the storage

system. Consequently, finding an appropriate time for the upgrade is very important.

For software and firmware updates, go to http://www.hp.com/go/msa. Select

MSA SAN Arrays, select your product, and go to Support.

For detailed steps on updating the firmware, see the reference guide.

Setting the Date and Time

You can set the date and time manually or configure the system to use Network

Time Protocol (NTP) to obtain them from a network-attached server. When NTP is

enabled, and if an NTP server is available, the system time and date can be obtained

from the NTP server. This allows multiple storage devices, hosts, log files, and so

forth to be synchronized.

NTP server time is provided in Universal Time (UT), which provides several

options:

n If you want to synchronize the times and logs between storage devices installed

in multiple time zones, set all the storage devices to use UT.

n If you want to use the local time for the device, select the appropriate time zone.

n If a time server can provide local time rather than UT, configure the storage

devices to use that time server, with no further time adjustment.

Page 48: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

48 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

If no NTP server is present, the date and time are maintained as if NTP had not been

enabled.

To manually set the system date and time:

1. Select Manage > General Config > Set Date/Time.

2. In the Set System Date panel, select the current month, day, and year.

3. In the Set System Time panel, type time values using a 24-hour clock (where hour 8

represents 8 a.m. and hour 20 represents 8 p.m.) and select the proper time zone.

4. Click Change Date/Time.

To obtain the date and time from an NTP server:

1. Select Manage > General Config > Set Date/Time.

2. In the Obtain Time With NTP panel, set Network Time Protocol to Enable and

optionally type the IP address of an NTP server.

If no IP server address is set, the system listens for time messages sent by an NTP

server in broadcast mode.

3. In the Set System Time panel, select the proper time zone.

4. Click Change Date/Time.

You might have to refresh the page to display updated values from the NTP server.

Creating Virtual Disks

Two or more disk drives can be logically combined to form a virtual disk. The

combined storage capacity can then be partitioned into volumes. SMU provides both

manual and automatic methods for creating virtual disks, as described in its online

help and in the reference guide.

As an example, the following steps use the manual method to create two virtual

disks with the following characteristics:

n RAID 5, in which parity is distributed across all disk drives in the virtual disk

n Five disk drives per virtual disk

n One spare disk drive dedicated to each virtual disk

n One volume per virtual disk, where the volume is not visible to data hosts

Page 49: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 4 Configuring a System for the First Time 49

To create both virtual disks:

1. Select Manage > Virtual Disk Config > Create A Vdisk.

2. Select Manual Virtual Disk Creation.

3. Type a name for the virtual disk.

The name is case-sensitive and can include 17 characters. Allowed characters

include letters, numbers, hyphens, underscores, and spaces.

4. Select RAID 5 – Parity RAID, Parity Distributed.

5. Click Create New Virtual Disk.

6. Select five drives of the same size and type (all SAS or all SATA).

7. For the dedicated spare drive option, select Yes and click Continue.

You can add a maximum of four available drives to a redundant virtual disk (RAID

1, 3, 5, 6, 10, and 50) for use as spares. If a drive in the virtual disk fails, one of

these vdisk spares is automatically used to reconstruct the virtual disk. A spare drive

must have sufficient capacity to replace the smallest drive in the virtual disk. Vdisk

spares are also called dedicated spares.

The controller automatically uses the vdisk spare for reconstruction of the critical

virtual disk to which it belongs. The virtual disk remains in Critical status until the

parity or mirror data is completely written to the spare, at which time the virtual

disk returns to Fault Tolerant status. For RAID 50 virtual disks, if more than one

sub-vdisk becomes critical, reconstruction and use of vdisk spares occur in the order

sub-vdisks are numbered.

Although using a vdisk spare is the most secure way to provide spares for your

virtual disks, it is also expensive to keep a spare assigned to each virtual disk. An

alternative method is to enable dynamic spares or to assign one or more unused

drives as global spares.

8. Select a drive to be the spare and click Continue.

9. For the number of volumes, select 1.

Notice that by default the volume will not be presented to (accessible by) hosts.

10. Click Create Virtual Disk.

A page is displayed that shows the progress of initializing the virtual disk.

11. Click the link to create another virtual disk.

12. Repeat Step 2 to Step 10 to create a second virtual disk with a different name.

Page 50: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

50 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Mapping a Volume to a Host

To enable a data host to access a volume you created, you must map the volume to

the host. The port World Wide Name (WWN) of each host connected to the system

is automatically added to the system’s global host port list.

Before mapping a data host to a volume you must identify the data host’s port

WWN and a LUN that the host is not using.

To map a data host to a volume:

1. Select Manage > Volume Management > Volume Mapping > Map Hosts To Volume.

Notice that your first virtual disk and its volume are selected, and the volume’s host

mapping values are set to None.

2. In the Add or Modify a Mapping panel:

a. Select the host WWN value that you identified before beginning.

b. Type the LUN.

c. Leave the access type set as read-write.

d. Select all ports.

e. Click Map It.

The host has read-write access to the volume through any controller host port.

Testing the Configuration

To determine that your system is ready for use, test the configuration as follows:

1. In SMU, select Monitor > Vdisk Status and view the configuration information for

each virtual disk.

The virtual disk status is Critical during initialization but you can perform I/O to the

volume.

2. From the data host:

a. Create a file system on the volume.

b. Verify that you can access the mapped volume and the volume size shown on the

data host matches the size shown in SMU.

c. Verify that you can write data to the volume.

Page 51: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 4 Configuring a System for the First Time 51

If the above tests succeed, your system is ready for use.

3. Optionally, unmount the volume and delete the vdisks created for test.

Logging Out of SMU

If you do not log out of SMU when you have finished using it, other manage users

cannot log in to the same controller module and your IP address stays logged in for

30 minutes (the default auto-logout timeout setting).

To log out of SMU:

1. Click Log Off at the bottom of the menu.

The Log Off page is displayed.

2. Click Log Off.

Page 52: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

52 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Page 53: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

53

CHAPTER 5

Troubleshooting

Fault Isolation Methodology

The MSA2000 Family storage system provides many ways to isolate faults within

the system. This section presents the basic methodology used to locate faults and the

associated FRUs.

The basic fault isolation steps are:

n Gather fault information, including by using system LEDs

n Determine where in the system the fault is occurring

n Review event logs

n If required, isolate the fault to a data path component

Gather Fault Information

When a fault occurs, it is important to gather as much information as possible.

Doing so will help you determine the correct action needed to remedy the fault.

Begin by reviewing the reported fault. Is the fault related to an internal data path or

an external data path? Is the fault related to a hardware component such as a drive

module, controller module, or power-and-cooling module? By isolating the fault to

one of the components within the storage system, you will be able to determine the

necessary action more rapidly.

Determine Where the Fault Is Occurring

Once you have an understanding of the reported fault, review the enclosure LEDs.

The enclosure LEDs are designed to alert users of any system faults and might be

what alerted the user to a fault in the first place.

Page 54: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

54 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

When a fault occurs, the Fault ID status LED on an enclosure’s right ear (see

Figure 1-1) illuminates. Check the LEDs on the back of the enclosure to narrow the

fault to a FRU, connection, or both. The LEDs also help you identify the location of

a FRU reporting a fault.

Use SMU to verify any faults found while viewing the LEDs. SMU is also a good

tool to use in determining where the fault is occurring if the LEDs cannot be viewed

due to the location of the system. SMU provides you with a visual representation of

the system and where the fault is occurring. It can also provide more detailed

information about FRUs, data, and faults.

Review the Event Logs

The event logs record all system events. It is very important to review the logs, not

only to identify the fault, but also to search for events that might have caused the

fault to occur. For example, a host could lose connectivity to a virtual disk if a user

changes channel settings without taking the storage resources assigned to it into

consideration. In addition, the type of fault can help you isolate the problem to

hardware or software.

Isolate the Fault

Occasionally it might become necessary to isolate a fault. This is particularly true

with data paths due to the number of components the data path consists of. For

example, if a host-side data error occurs, it could be caused by any of the

components in the data path: controller module, cable, or data host.

Page 55: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 5 Troubleshooting 55

If the Enclosure Does Not Initialize

It may take up to two minutes for the enclosures to initialize. If the enclosure does

not initialize:

n Perform a rescan.

n Power cycle the system.

n Make sure the power cord is properly connected and check the power source that

it is connected to.

n Check the event log for errors.

Correcting Enclosure IDs

When installing a system with drive enclosures attached, the enclosure IDs might

not agree with the physical cabling order. This is because the controller might have

been previously attached to some of the same enclosures and it attempts to preserve

the previous enclosure IDs if possible. To correct this condition, make sure that both

controllers are up and perform a rescan using SMU or the CLI. This will reorder the

enclosures, but can take up to two minutes for the enclosure IDs to be corrected.

To perform a rescan using the CLI, type the following command:

To rescan using SMU:

1. Select Manage > General Config > Enclosure Management > Reorder Enclosure

IDs.

2. In the Reorder Enclosure IDs panel, click Rescan.

rescan

Page 56: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

56 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Using System LEDs to Diagnose Problems

This section describes possible reasons and actions to take when an LED indicates a

fault condition. See “System Components” on page 11 for descriptions of all LED

statuses.

Is the front panel Fault ID amber?

Is the controller back panel OK LED off?

Answer Possible Reasons Actions

No System functioning properly. No action required.

Yes A fault condition exits. • Check the LEDs on the back of the

controller to narrow the fault to a

FRU, connection, or both.

• Check the event log for specific

information regarding the fault.

Answer Possible Reasons Actions

No System functioning properly. No action required

Yes • The controller module is not

powered on.

• The controller module has

failed.

• Check that the controller module is

fully inserted and latched in place,

and that the enclosure is powered

on.

• Check the event log for specific

information regarding the failure.

Page 57: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 5 Troubleshooting 57

Is the controller back panel Fault/Service Required LED amber?

Are both drive module LEDs, Online/Activity, and Fault/UID LEDs off?

Answer Possible Reasons Actions

No System functioning properly. No action required.

Yes

(blinking)

One of the following errors

occurred:

• Hardware-controlled power-

up error

• Cache flush error

• Cache self-refresh error

• Restart this controller from the

other controller using SMU or the

CLI.

• Remove the controller and reinsert

it.

• Contact an authorized service

provider for assistance.

• Replace the controller.

Yes An enclosure-level fault

occurred.

If installing a controller FRU,

the module has not gone online

and likely failed its self-test.

• Check the event log for specific

information regarding the fault.

• Isolate the fault.

• Contact an authorized service

provider for assistance.

• If installing a controller FRU,

restart the controller and check the

event log for errors.

Answer Possible Reasons Actions

Yes • There is no power.

• The drive is offline.

• The drive is not configured.

• Check that the drive is fully

inserted and latched in place, and

that the enclosure is powered on.

Page 58: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

58 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Is the drive module Fault/UID led blinking amber?

Answer Possible Reasons Actions

No, but the Online/Activity

LED is blinking

The drive is

rebuilding.

No action required.

Note: Do not remove a drive

that is rebuilding. Removing a

drive may terminate the current

operation and cause data loss.

Yes, and the

Online/Activity LED is off

The drive is offline.

A predictive failure

alert may have been

received for this

device.

• Check the event log for

specific information regarding

the fault.

• Isolate the fault.

• Contact an authorized service

provider for assistance.

Yes, and the

Online/Activity LED is on

The drive is online,

but there is no

activity. A

predictive failure

alert may have been

received for this

device.

• Check the event log for

specific information regarding

the fault.

• Isolate the fault.

• Contact an authorized service

provider for assistance.

Yes, and the

Online/Activity LED is

blinking

The drive is active,

but a predictive

failure alert may

have been received

for this device.

• Check the event log for

specific information regarding

the fault.

• Isolate the fault.

• Contact an authorized service

provider for assistance.

Page 59: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 5 Troubleshooting 59

Is a connected port’s Host Link Status LED off?

Is a connected port’s Expansion Port status LED off?

Answer Possible Reasons Actions

No System functioning properly. No action required.

Yes The link is down. • Check cable connections.

• Reseat cables.

• Replace cables.

• In SMU, review the event logs for

indicators of a specific fault in a

host data path component.

Answer Possible Reasons Actions

No System functioning properly. No action required.

Yes The link is down. • Check cable connections.

• Reseat cables.

• Replace cables.

• In SMU, review the event logs for

indicators of a specific fault in a

host data path component.

Page 60: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

60 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Is a connected port’s Ethernet link status LED off?

Is the power-and-cooling module AC Power Good LED off?

Answer Possible Reasons Actions

No System functioning properly. No action required.

Yes The link is down. Use standard networking

troubleshooting procedures to isolate

faults on the network.

Answer Possible Reasons Actions

No System functioning properly. No action required.

Yes The module is not receiving

adequate power.

• Verify that the power cord is

properly connected and check the

power source it is connected to.

• heck that the power-and-cooling

supply FRU is firmly locked into

position.

• Check the event log for specific

information regarding the fault.

• Isolate the fault.

• Contact an authorized service

provider for assistance.

Page 61: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 5 Troubleshooting 61

Is the power-and-cooling module DC Voltage/Fan Fault/Service Required LED amber?

Is the drive enclosure back panel OK LED off?

Answer Possible Reasons Actions

No System functioning properly. No action required.

Yes The power supply unit or a fan

is operating at an unacceptable

voltage/RPM level, or has

failed.

When isolating faults in the power-

and-cooling module, remember that

the fans in both modules receive

power through a common bus on the

midplane, so if a power supply unit

fails, the fans continue to operate

normally.

• Check that the power-and-cooling

supply FRU is firmly locked into

position.

• Check that the AC cord is

connected to a power source.

• Check that the AC cord is

connected to the power-and-

cooling module.

Answer Possible Reasons Actions

No System functioning properly No action required

Yes • The expansion module is not

powered on.

• The controller module has

failed.

• Check that the drive is fully

inserted and latched in place,

• Check that the enclosure is

powered on.

• Check that the AC cord is

connected to a power source.

• Check the event log for specific

information regarding the failure.

Page 62: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

62 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Is the drive enclosure Fault/Service Required LED amber?

Answer Possible Reasons Actions

No System functioning properly. No action required.

Yes

(blinking)

One of the following errors

occurred:

• Hardware-controlled power-

up error

• Cache flush error

• Cache self-refresh error

• Check the event log for specific

information regarding the fault.

• Isolate the fault.

• Contact an authorized service

provider for assistance.

• Replace if necessary.

Yes A fault occurred.

If installing an I/O module

FRU, the module has not gone

online and likely failed its self-

test.

• Check the event log for specific

information regarding the fault.

• Isolate the fault.

• Contact an authorized service

provider for assistance.

• Replace if necessary.

• If installing an I/O module FRU,

try removing and reinstalling the

new I/O module, and check the

event log for errors.

Page 63: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 5 Troubleshooting 63

Isolating a Host-Side Connection Fault

During normal operation, when a controller module host port is connected to a data

host, the port’s host link status LED and host link activity LED are green. If there is

I/O activity, the host activity LED blinks green. If data hosts are having trouble

accessing the storage system, and you cannot locate a specific fault or cannot access

the event logs, use the following procedure. This procedure requires scheduled

downtime.

Note – Do not perform more than one step at a time. Changing more than one

variable at a time can complicate the troubleshooting process.

1. Halt all I/O to the storage system.

2. Check the host activity LED.

If there is activity, halt all applications that access the storage system.

3. Reseat the SAS cable.

Is the host link status LED on?

n Yes – Monitor the status to ensure that there is no intermittent error present. If

the fault occurs again, clean the connections to ensure that a dirty connector is

not interfering with the data path.

n No – Proceed to the next step.

4. Move the SAS cable to a port with a known good link status.

This step isolates the problem to the external data path (host cable and host-side

devices) or to the controller module port.

Is the host link status LED on?

n Yes – You now know that the host cable and host-side devices are functioning

properly. Return the cable to the original port. If the link status LED remains off,

you have isolated the fault to the controller module’s port. Replace the controller

module.

n No – Proceed to the next step.

5. Replace the HBA with a known good HBA, or move the host side cable to a known

good HBA.

Page 64: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

64 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Is the host link status LED on?

n Yes – You have isolated the fault to the HBA. Replace the HBA.

n No – It is likely that the controller module needs to be replaced.

6. Move the cable back to its original port.

Is the host link status LED on?

n No – The controller module’s port has failed. Replace the controller module.

n Yes – Monitor the connection for a period of time. It may be an intermittent

problem, which can occur with damaged cables and HBAs.

Isolating a Controller Module Expansion Port Connection Fault

During normal operation, when a controller module’s expansion port is connected to

a drive enclosure, the expansion port status LED is green. If the connected port’s

expansion port LED is off, the link is down. Use the following procedure to isolate

the fault.

This procedure requires scheduled downtime.

Note – Do not perform more than one step at a time. Changing more than one

variable at a time can complicate the troubleshooting process.

1. Halt all I/O to the storage system.

2. Check the host activity LED.

If there is activity, halt all applications that access the storage system.

3. Reseat the expansion cable.

Is the expansion port status LED on?

n Yes – Monitor the status to ensure there is no intermittent error present. If the

fault occurs again, clean the connections to ensure that a dirty connector is not

interfering with the data path.

n No – Proceed to Step 4.

Page 65: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 5 Troubleshooting 65

4. Move the expansion cable to a port on the RAID enclosure with a known good link

status.

This step isolates the problem to the expansion cable or to the controller module’s

expansion port.

Is the expansion port status LED on?

n Yes – You now know that the expansion cable is good. Return cable to the

original port. If the expansion port status LED remains off, you have isolated

the fault to the controller module’s expansion port. Replace the controller

module.

n No – Proceed to the next step.

5. Move the expansion cable back to the original port on the controller enclosure.

6. Move the expansion cable on the drive enclosure to a known good expansion port

on the drive enclosure.

Is the expansion port status LED on?

n Yes – You have isolated the problem to the drive enclosure’s port. Replace the

expansion module.

n No – Proceed to Step 7.

7. Replace the cable with a known good cable, ensuring the cable is attached to the

original ports used by the previous cable.

Is the host link status LED on?

n Yes – Replace the original cable. The fault has been isolated.

n No – It is likely that the controller module needs to be replaced

Page 66: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

66 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Resolving Voltage and Temperature Warnings

1. Check that all of the fans are working by making sure each power-and-cooling

module’s DC Voltage/Fan Fault/Service Required LED is off or by using SMU to

check the Status Summary page (select Monitor > Status > Status Summary).

2. Make sure that all modules are fully seated in their slots and that their latches are

locked.

3. Make sure that no slots are left open for more than two minutes.

If you need to replace a module, leave the old module in place until you have the

replacement or use a blank module to fill the slot. Leaving a slot open negatively

affects the airflow and can cause the enclosure to overheat.

4. Try replacing each power-and-cooling module one at a time.

5. Replace the controller modules, one at a time.

Sensor Locations

The storage system monitors conditions at different points within each enclosure to

alert you to problems. Power, cooling fan, temperature, and voltage sensors are

located at key points in the enclosure. In each controller module and expansion

module, the enclosure management processor (EMP) monitors the status of these

sensors to perform SCSI enclosure services (SES) functions. Various SMU pages

display the sensor information, for example Monitor > Status > Module Status.

The following sections describe each element and its sensors.

Page 67: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 5 Troubleshooting 67

Power Supply Sensors

Each enclosure has two fully redundant power-and-cooling modules with load-

sharing capabilities. The power supply sensors described in the following table

monitor the voltage, temperature, and fans in each power-and-cooling module. If the

power supply sensors report a voltage that is under or over the threshold, check the

input voltage.

Cooling Fan Sensors

Each power-and-cooling module includes two fans. The normal range for fan speed

is 4000 to 6000 RPM. When a fan’s speed drops below 4000 RPM, the EMP

considers it a failure and posts an alarm in the storage system’s event log. The

following table lists the description, location, and alarm condition for each fan. If

the fan speed remains under the 4000 RPM threshold, the internal enclosure

temperature may continue to rise. Replace the power-and-cooling module reporting

the fault.

During a shutdown, the cooling fans do not shut off. This allows the enclosure to

continue cooling.

Table 5-1 Power Supply Sensors

Description Location Event/Fault ID LED Condition

Power supply 1 Power-and-cooling module 0 Voltage, temperature, or fan fault

Power supply 2 Power-and-cooling module 1 Voltage, temperature, or fan fault

Table 5-2 Cooling Fan Sensor Descriptions

Description Location Event/Fault ID LED Condition

Fan 0 Power-and-cooling module 0 < 4000 RPM

Fan 1 Power-and-cooling module 0 < 4000 RPM

Fan 2 Power-and-cooling module 1 < 4000 RPM

Fan 3 Power-and-cooling module 1 < 4000 RPM

Page 68: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

68 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Temperature Sensors

Extreme high and low temperatures can cause significant damage if they go

unnoticed. Each controller module has six temperature sensors. Of these, if the CPU

or FPGA temperature reaches a shutdown value, the controller module is

automatically shut down. Each power-and-cooling module has one temperature

sensor.

When a temperature fault is reported, it must be remedied as quickly as possible to

avoid system damage. This can be done by warming or cooling the installation

location.

When a power supply sensor goes out of range, the Fault/ID LED illuminates amber

and an event is logged to the event log.

Table 5-3 Controller Module Temperature Sensors

Description

Normal Operating Range

Warning Operating Range

Critical Operating Range

Shutdown Values

CPU Temperature 3–88° C 0–3° C,

88–90° C

> 90° C 0° C

100° C

FPGA Temperature 3–97° C 0–3° C,

97–100° C

None 0° C

100° C

Onboard Temperature 1 0–70° C None None None

Onboard Temperature 2 0–70° C None None None

Onboard Temperature 3

(Capacitor Temperature)

0–70° C None None None

CM Temperature 5–50° C <=5 ° C,

>= 50 ° C

<=0 ° C,

>= 55 ° C

None

Table 5-4 Power-and-Cooling Module Temperature Sensors

Description Normal Operating Range

Power Supply 1 Temperature

(power-and-cooling module 0)

0–80° C

Power Supply 2 Temperature

(power-and-cooling module 0)

0–80° C

Page 69: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Chapter 5 Troubleshooting 69

To view the controller enclosure’s temperature status, in SMU, as an Advanced

Manage user:

l Select Monitor > Status > Advanced Settings > Temperature Status.

Power-and-Cooling Module Voltage Sensors

Power supply voltage sensors ensure that an enclosure’s power supply voltage is

within normal ranges. There are three voltage sensors per power-and-cooling

module.

Table 5-5 Voltage Sensor Descriptions

Sensor Event/Fault ID LED Condition

Power Supply 1 Voltage, 12V < 11.00V

> 13.00V

Power Supply 1 Voltage, 5V < 4.00V

> 6.00V

Power Supply 1 Voltage, 3.3V < 3.00V

> 3.80V

Page 70: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

70 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Page 71: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

71

APPENDIX A

Environmental Requirements and Specifications

Safety Requirements

Install the system in accordance with the local safety codes and regulations at the

facility site. Follow all cautions and instructions marked on the equipment.

Site Requirements and GuidelinesThe following sections provide requirements and guidelines that you must address

when preparing your site for the installation.

When selecting an installation site for the system, choose a location not subject to

excessive heat, direct sunlight, dust, or chemical exposure. These conditions greatly

reduce the system’s longevity and might void your warranty.

Site Wiring and AC Power Requirements

The following are required for all installations:

n All AC mains and supply conductors to power distribution boxes for the rack-

mounted system must be enclosed in a metal conduit or raceway when specified

by local, national, or other applicable government codes and regulations.

n Ensure that the voltage and frequency of your power source match the voltage

and frequency inscribed on the equipment’s electrical rating label.

n To ensure redundancy, provide two separate power sources for the enclosures.

These power sources must be independent of each other, and each must be

controlled by a separate circuit breaker at the power distribution point.

n The system requires voltages within minimum fluctuation. The customer-

supplied facilities’ voltage must maintain a voltage with not more than

±5 percent fluctuation. The customer facilities must also provide suitable surge

protection.

Page 72: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

72 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

n Site wiring must include an earth ground connection to the AC power source.

The supply conductors and power distribution boxes (or equivalent metal

enclosure) must be grounded at both ends.

n Power circuits and associated circuit breakers must provide sufficient power and

overload protection. To prevent possible damage to the AC power distribution

boxes and other components in the rack, use an external, independent power

source that is isolated from large switching loads (such as air conditioning

motors, elevator motors, and factory loads).

Weight and Placement Guidelines

Refer to “Physical Requirements” on page 74 for detailed size and weight

specifications.

n The weight of an enclosure depends on the number and type of modules installed,

as shown in Table A-2.

n Ideally, use two people to lift an enclosure. However, one person can safely lift

an enclosure if its weight is reduced by removing the power and cooling modules

and drive modules.

n Do not place enclosures in a vertical position. Always install and operate the

enclosures in a horizontal orientation.

n When installing enclosures in a rack, make sure that any surfaces over which you

might move the rack can support the weight. To prevent accidents when moving

equipment, especially on sloped loading docks and up ramps to raised floors,

ensure you have a sufficient number of helpers. Remove obstacles such as cables

and other objects from the floor.

n To prevent the rack from tipping and to minimize personnel injury in the event of

a seismic occurrence, securely anchor the rack to a wall or other rigid structure

that is attached to both the floor and to the ceiling of the room.

Page 73: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Appendix A Environmental Requirements and Specifications 73

Electrical Guidelinesn These enclosures work with single-phase power systems having an earth ground

connection. To reduce the risk of electric shock, do not plug an enclosure into

any other type of power system. Contact your facilities manager or a qualified

electrician if you are not sure what type of power is supplied to your building.

n Enclosures are shipped with a grounding-type (three-wire) power cord. To reduce

the risk of electric shock, always plug the cord into a grounded power outlet.

n Do not use household extension cords with the enclosures. Not all power cords

have the same current ratings. Household extension cords do not have overload

protection and are not meant for use with computer systems.

Ventilation Requirements

Refer to “Environmental Requirements” on page 75 for detailed environmental

requirements.

n Do not block or cover ventilation openings at the front and rear of an enclosure.

Never place an enclosure near a radiator or heating vent. Failure to follow these

guidelines can cause overheating and affect the reliability and warranty of your

enclosure.

n Leave a minimum of 6 inches (15 cm) at the front and back of each enclosure to

ensure adequate airflow for cooling. No cooling clearance is required on the

sides, top, or bottom of enclosures.

n Leave enough space in front and in back of an enclosure to allow access to

enclosure components for servicing. Removing a component requires a clearance

of at least 15 inches (37 cm) in front of and behind the enclosure.

Cabling Requirementsn Keep power and interface cables clear of foot traffic. Route cables in locations

that protect the cables from damage.

n Route interface cables away from motors and other sources of magnetic or radio

frequency interference.

n Stay within the cable length limitations.

Page 74: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

74 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Management Host Requirements

A local management host with at least one serial port connection is recommended

for the initial installation and configuration of a controller enclosure. After you

configure one or both of the controller modules with an Internet Protocol (IP)

address, you then use a remote management host on an Ethernet network to

configure, manage, and monitor.

Note – Connections to this device must be made with shielded cables with metallic

RFI/EMI connector hoods in order to maintain compliance with FCC Rules and

Regulations.

Physical Requirements

The floor space at the installation site must be strong enough to support the

combined weight of the rack, controller enclosures, expansion enclosures, and any

additional equipment. The site also requires sufficient space for installation,

operation, and servicing the enclosures, and also requires sufficient ventilation to

allow a free flow of air to all enclosures.

Table A-1 and Table A-2 list enclosure dimensions and weights. Weights are based

on an enclosure having 12 drive modules, two controller or expansion modules, and

two power-and-cooling modules installed.

Table A-1 Rackmount Enclosure Dimensions

Specification Rackmount

Height 2U 3.5 inches (8.9 cm)

Width:

• Chassis excluding mounting ears

• Chassis including mounting ears

17.6 inches (44.7 cm)

18.9 inches (48.0 cm)

Depth:

• Chassis

• To back of power-and-cooling module

handle

21.8 inches (55.4 cm)

23.7 inches (60.2 cm)

Page 75: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Appendix A Environmental Requirements and Specifications 75

Environmental Requirements

Table A-2 Rackmount Enclosure Weights

Specification Rackmount

2012sa Modular Smart Array (12 drives)

• SAS drives

• SATA drives

64.5 lb (29.3 kg)

65.5 lb (29.8 kg)

MSA2000 Drive Enclosure (12 drives)

• SAS drives

• SATA drives

62 lb (28.2 kg)

63 lb (28.6 kg)

Table A-3 Operating Environmental Specifications

Specification Range

Altitude To 9842 feet (3000 meters), derate 35.6° F (2° C) for every

3281 feet (1 km) up to 9842 feet (3000 meters)

Relative Humidity 10% to 90% RH, 104° F (40° C) non condensing

Temperature 41° F to 104° F (5° C to 40° C)

Shock 5.0 g, 10 ms, half-sine

Vibration 0.5 g, 1 octave/minute, 5 Hz to 500 Hz to 5 Hz, swept-sine

Page 76: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

76 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Electrical Requirements

Site Wiring and Power Requirements

Each enclosure has two power and cooling modules for redundancy. If full

redundancy is required, use a separate power source for each module. The AC

power supply unit in each power and cooling module is auto-ranging and is

automatically configured to an input voltage range from 88–264 VAC with an input

frequency of 47–63 Hz. The power and cooling modules meet standard voltage

requirements for both U.S. and international operation. The power and cooling

modules use standard industrial wiring with line-to-neutral or line-to-line power

connections.

Power Cord Requirements

Each enclosure is shipped with two AC power cords that are appropriate for use in

a typical outlet in the destination country. Each power cord connects one of the

power and cooling modules to an independent, external power source. To ensure

power redundancy, connect the two power cords to two separate circuits; for

example, to one commercial circuit and one uninterruptible power source (UPS).

Page 77: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

77

APPENDIX B

Regulatory Compliance and Safety

Regulatory Compliance

Federal Communications Commission Notice

Part 15 of the Federal Communications Commission (FCC) Rules and Regulations

has established Radio Frequency (RF) emission limits to provide an interference-

free radio frequency spectrum. Many electronic devices, including computers,

generate RF energy incidental to their intended function and are, therefore, covered

by these rules. These rules place computers and related peripheral devices into two

classes, A and B, depending upon their intended installation. Class A devices are

those that may reasonably be expected to be installed in a business or commercial

environment. Class B devices are those that may reasonably be expected to be

installed in a residential environment (i.e., personal computers). The FCC requires

devices in both classes to bear a label indicating the interference potential of the

device as well as additional operating instructions for the user.

The rating label on the device shows which class (A or B) the equipment falls into.

Class B devices have an FCC logo or FCC ID on the label. Class A devices do not

have an FCC logo or FCC ID on the label. Once the class of the device is

determined, refer to the following corresponding statement.

Class A Equipment

This equipment has been tested and found to comply with the limits for a Class A

digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to

provide reasonable protection against harmful interference when the equipment is

operated in a commercial environment. This equipment generates, uses, and can

radiate radio frequency energy and, if not installed and used in accordance with the

Page 78: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

78 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

instructions, may cause harmful interference to radio communications. Operation of

this equipment in a residential area is likely to cause harmful interference, in which

case the user will be required to correct the interference at personal expense.

Class B Equipment

This equipment has been tested and found to comply with the limits for a Class B

digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to

provide reasonable protection against harmful interference in a residential

installation. This equipment generates, uses, and can radiate radio frequency energy

and, if not installed and used in accordance with the instructions, may cause harmful

interference to radio communications. However, there is no guarantee that

interference will not occur in a particular installation. If this equipment does cause

harmful interference to radio or television reception, which can be determined by

turning the equipment off and on, the user is encouraged to try to correct the

interference by one or more of the following measures:

n Reorient or relocate the receiving antenna.

n Increase the separation between the equipment and receiver.

n Connect the equipment into an outlet on a circuit that is different from that to

which the receiver is connected.

n Consult the dealer or an experienced radio or television technician for help.

Declaration of Conformity for Products Marked With the FCC logo, United States only

This device complies with Part 15 of the FCC Rules. Operation is subject to the

following two conditions: (1) this device may not cause harmful interference, and

(2) this device must accept any interference received, including interference that

may cause undesired operation.

For questions regarding your product, visit http://www.hp.com.

For questions regarding this FCC declaration, contact us by mail or telephone:

n Hewlett-Packard Company

P.O. Box 692000, Mailstop 510101

Houston, Texas 77269-2000

n 1-281-514-3333

Page 79: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Appendix B Regulatory Compliance and Safety 79

To identify this product, refer to the part, Regulatory Model Number, or product

number found on the product.

Modifications

The FCC requires the user to be notified that any changes or modifications made to

this device that are not expressly approved by Hewlett-Packard Company may void

the user's authority to operate the equipment.

Cables

Connections to this device must be made with shielded cables with metallic

RFI/EMI connector hoods in order to maintain compliance with FCC Rules and

Regulations.

Regulatory Compliance Identification Numbers

For the purpose of regulatory compliance certifications and identification, your

product has been assigned a unique Regulatory Model Number. The RMN can be

found on the product nameplate label, along with all required approval markings

and information. When requesting compliance information for this product, always

refer to this RMN. The Regulatory Model Number should not be confused with the

marketing name or model number of the product.

Regulatory Compliance Label Location

The Regulatory Compliance label for the 2012sa Modular Smart Array is located

behind the left ear on the side of the chassis as shown in Figure 5-1.

Page 80: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

80 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Figure 5-1 Regulatory Compliance Label Location

Laser Device

All HP systems equipped with a laser device comply with safety standards,

including International Electrotechnical Commission (IEC) 825. With specific

regard to the laser, the equipment complies with laser product performance

standards set by government agencies as a Class 1 laser product. The product does

not emit hazardous light.

Laser Safety Warning

Warning – To reduce the risk of exposure to hazardous radiation:

n Do not try to open the laser device enclosure. There are no user-serviceable

components inside.

n Do not operate controls, make adjustments, or perform procedures to the laser

device other than those specified herein.

n Allow only HP authorized service technicians to repair the laser device.

Regulatory compliance label

Page 81: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Appendix B Regulatory Compliance and Safety 81

Certification and Classification Information

This product contains a laser internal to the fiber optic (FO) transceiver for

connection to the Fibre Channel communications port.

In the USA, the FO transceiver is certified as a Class 1 laser product conforming to

the requirements contained in the Department of Health and Human Services

(DHHS) regulation 21 CFR, Subchapter J. A label on the plastic FO transceiver

housing indicates the certification.

Outside the USA, the FO transceiver is certified as a Class 1 laser product

conforming to the requirements contained in IEC 825-1:1993 and EN 60825-1:1994,

including Amendment 11:1996 and Amendment 2:2001.

Laser Product Label

The optional label in Figure 5-2 or equivalent may be located on the surface of the

HP supplied laser device.

Figure 5-2 Class 1 Laser Product Label

International Notices and Statements

Canadian Notice (avis Canadien)

Class A Equipment

This Class A digital apparatus meets all requirements of the Canadian Interference-

Causing Equipment Regulations.

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement

sur le matériel brouilleur du Canada.

This optional label indicates that the product is classified as a

CLASS 1 LASER PRODUCT. This label may appear on the laser

device installed in your product.

Page 82: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

82 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Class B Equipment

This Class B digital apparatus meets all requirements of the Canadian Interference-

Causing Equipment Regulations.

Cet appareil numérique de la classe B respecte toutes les exigences du Règlement

sur le matériel brouilleur du Canada.

European Union Notice

Products bearing the CE marking comply with the EMC Directive (89/336/EEC)

and the Low Voltage Directive (73/23/EEC) issued by the Commission of the

European Community and if this product has telecommunication functionality, the

R&TTE Directive (1999/5/EC).

Compliance with these directives implies conformity to the following European

Norms (in parentheses are the equivalent international standards and regulations):

n EN55022 (CISPR 22) - Electromagnetic Interference

n EN55024 (IEC61000-4-2, IEC61000-4-3, IEC61000-4- 4, IEC61000-4-5,

IEC61000-4-6, IEC61000-4-8, IEC61000-4-11) - Electromagnetic Immunity

n Power Quality:

n EN61000-3-2 (IEC61000-3-2) - Power Line Harmonics

n EN61000-3-3 (IEC61000-3-3) - Power Line Flicker

n EN60950 (IEC60950) - Product Safety

n Also approved under UL 60950/CSA C22.2 No. 60950-00, Safety of Information

Technology Equipment.

BSMI Notice

Page 83: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Appendix B Regulatory Compliance and Safety 83

Japanese Notice

Korean Notices

Page 84: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

84 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Safety

Battery Replacement Notice

Your computer is equipped with a lithium manganese dioxide, a vanadium

pentoxide, or an alkaline internal battery or battery pack. There is a danger of

explosion and risk of personal injury if the battery is incorrectly replaced or

mistreated. Replacement is to be done by an HP authorized service provider using

the HP spare part designated for this product. For more information about battery

replacement or proper disposal, contact an HP authorized reseller or HP authorized

service provider.

Warning – Your computer contains an internal lithium manganese dioxide, a

vanadium pentoxide, or an alkaline battery pack. There is risk of fire and burns if

the battery pack is not properly handled. To reduce the risk of personal injury:

n Do not attempt to recharge the battery.

n Do not expose to temperatures higher than 60°C.

n Do not disassemble, crush, puncture, short external contacts, or dispose of in fire

or water.

n Replace only with the HP spare part designated for this product.

For more information about battery replacement or proper disposal, contact an HP

authorized reseller or service provider.

Taiwan Battery Recycling Notice

Batteries, battery packs, and accumulators should not be disposed of together with the

general household waste. To forward them to recycling or proper disposal, please use the

public collection system or return them to HP, an authorized HP Partner, or their agents.

The Taiwan EPA requires dry battery manufacturing or importing firms

in accordance with Article 15 of the Waste Disposal Act to indicate the recovery marks on the batteries used in sales, giveaway or promotion.

Contact a qualified Taiwanese recycler for proper battery disposal.

Page 85: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Appendix B Regulatory Compliance and Safety 85

Power Cords

The power cord set must meet the requirements for use in the country where the

product was purchased. If the product is to be used in another country, purchase a

power cord that is approved for use in that country.

The power cord must be rated for the product and for the voltage and current

marked on the product electrical ratings label. The voltage and current rating of the

cord should be greater than the voltage and current rating marked on the product. In

addition, the diameter of the wire must be a minimum of 1.00 mm2 or 18 AWG, and

the length of the cord must be between 1.8 m (6 ft) and 3.6 m (12 ft). If you have

questions about the type of power cord to use, contact an HP authorized service

provider.

Note – Route power cords so that they will not be walked on and cannot be pinched

by items placed upon or against them. Pay particular attention to the plug, electrical

outlet, and the point where the cords exit from the product.

Japanese Power Cord Notice

Electrostatic Discharge

To prevent damage to the system, be aware of the precautions you need to follow

when setting up the system or handling parts. A discharge of static electricity from

a finger or other conductor may damage system boards or other static-sensitive

devices. This type of damage may reduce the life expectancy of the device.

Preventing Electrostatic Damage

To prevent electrostatic damage, observe the following precautions:

n Avoid hand contact by transporting and storing products in static-safe containers.

n Keep electrostatic-sensitive parts in their containers until they arrive at static-free

workstations.

Page 86: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

86 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

n Place parts on a grounded surface before removing them from their containers.

n Avoid touching pins, leads, or circuitry.

n Always be properly grounded when touching a static-sensitive component or

assembly (see “Grounding Methods” on page 86).

Grounding Methods

There are several methods for grounding. Use one or more of the following methods

when handling or installing electrostatic-sensitive parts:

n Use a wrist strap connected by a ground cord to a grounded workstation or

computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm

(±10 percent) resistance in the ground cords. To provide proper ground, wear the

strap snug against the skin.

n Use heel straps, toe straps, or boot straps at standing workstations. Wear the

straps on both feet when standing on conductive floors or dissipating floor mats.

n Use conductive field service tools.

n Use a portable field service kit with a folding static-dissipating work mat.

If you do not have any of the suggested equipment for proper grounding, have an

HP authorized reseller install the part.

Note – For more information on static electricity, or assistance with product

installation, contact your HP authorized reseller.

Page 87: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Appendix B Regulatory Compliance and Safety 87

Waste Electrical and Electronic Equipment Directive

Czechoslovakian Notice

Danish Notice

Bortskaffelse af affald fra husstande i den Europæiske Union

Hvis produktet eller dets emballage er forsynet med dette symbol, angiver det,at produktet ikke må bortskaffes med andet almindeligt husholdningsaffald. I stedet er det dit ansvar at bortskaffe kasseret udstyr ved at aflevere det på den kommunale genbrugsstation, der forestår genvinding af kasseret elektrisk og elektronisk udstyr. Den centrale modtagelse og genvinding af kasseret udstyr i forbindelse med bortskaffelsen bidrager til bevarelse af naturlige ressourcer

og sikrer, at udstyret genvindes på en måde, der beskytter både mennesker og miljø. Yderligere oplysninger om, hvor du kan aflevere kasseret udstyr til genvinding, kan du få hos kommunen, den lokale genbrugsstation eller i den butik, hvor du købte produktet.

Page 88: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

88 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Dutch Notice

English Notice

Disposal of waste equipment by users in private household in the European Union

This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your

waste equipment for recycling, please contact your local city office, your household waste disposal service, or the shop where you purchased the product.

Verwijdering van afgedankte apparatuur door privé-gebruikers in de Europese Unie

Dit symbool op het product of de verpakking geeft aan dat dit product niet mag worden gedeponeerd bij het normale huishoudelijke afval. U bent zelf verantwoordelijk voor het inleveren van uw afgedankte apparatuur bij een inzamelingspunt voor het recyclen van oude elektrische en elektronische apparatuur. Door uw oude apparatuur apart aan te bieden en te recyclen, kunnen natuurlijke bronnen worden behouden en kan het materiaal worden

hergebruikt op een manier waarmee de volksgezondheid en het milieu worden beschermd. Neem contact op met uw gemeente, het afvalinzamelingsbedrijf of de winkel waar u het product hebt gekocht voor meer informatie over inzamelingspunten waar u oude apparatuur kunt aanbieden voor recycling.

Page 89: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Appendix B Regulatory Compliance and Safety 89

Estonian Notice

Finnish Notice

Seadmete jäätmete kõrvaldamine eramajapidamistes Euroopa Liidus

See tootel või selle pakendil olev sümbol näitab, et kõnealust toodet ei tohi

koos teiste majapidamisjäätmetega kõrvaldada. Teie kohus on oma

seadmete jäätmed kõrvaldada, viies need elektri- ja elektroonikaseadmete

jäätmete ringlussevõtmiseks selleks ettenähtud kogumispunkti. Seadmete

jäätmete eraldi kogumine ja ringlussevõtmine kõrvaldamise ajal aitab kaitsta

loodusvarasid ning tagada, et ringlussevõtmine toimub viisil, mis kaitseb inimeste tervist

ning keskkonda. Lisateabe saamiseks selle kohta, kuhu oma seadmete jäätmed

ringlussevõtmiseks viia, võtke palun ühendust oma kohaliku linnakantselei,

majapidamisjäätmete kõrvaldamise teenistuse või kauplusega, kust Te toote ostsite.

Laitteiden hävittäminen kotitalouksissa Euroopan unionin alueella

Jos tuotteessa tai sen pakkauksessa on tämä merkki, tuotetta ei saa hävittää kotitalousjätteiden mukana. Tällöin hävitettävä laite on toimitettava sähkölaitteidja elektronisten laitteiden kierrätyspisteeseen. Hävitettävien laitteiden erillinen käsittely ja kierrätys auttavat säästämään luonnonvaroja ja varmistamaan, että laite kierrätetään tavalla, joka estää terveyshaitat ja suojelee luontoa. Lisätietojapaikoista, joihin hävitettävät laitteet voi toimittaa kierrätettäväksi, saa ottamalla

yhteyttä jätehuoltoon tai liikkeeseen, josta tuote on ostettu.

Page 90: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

90 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

French Notice

German Notice

Élimination des appareils mis au rebut par les ménages dans l'Union européenne

Le symbole apposé sur ce produit ou sur son emballage indique que ce produit ne doit pas être jeté avec les déchets ménagers ordinaires. Il est de votre responsabilité de mettre au rebut vos appareils en les déposant dans les centres de collecte publique désignés pour le recyclage des équipements électriques et électroniques. La collecte et le recyclage de vos appareils mis au rebut indépendamment du reste des déchets contribue à la préservation des ressources

naturelles et garantit que ces appareils seront recyclés dans le respect de la santé humaine et de l'environnement. Pour obtenir plus d'informations sur les centres de collecte et de recyclage des appareils mis au rebut, veuillez contacter les autorités locales de votre région, les services de collecte des ordures ménagères ou le magasin dans lequel vous avez acheté ce produit.

Entsorgung von Altgeräten aus privaten Haushalten in der EU

Das Symbol auf dem Produkt oder seiner Verpackung weist darauf hin, dass das Produkt nicht über den normalen Hausmüll entsorgt werden darf. Benutzer sind verpflichtet, die Altgeräte an einer Rücknahmestelle für Elektro- und Elektronik-Altgeräte abzugeben. Die getrennte Sammlung und ordnungsgemäßEntsorgung Ihrer Altgeräte trägt zur Erhaltung der natürlichen Ressourcen bei und garantiert eine Wiederverwertung, die die Gesundheit des Menschen und

die Umwelt schützt. Informationen dazu, wo Sie Rücknahmestellen für Ihre Altgeräte findenerhalten Sie bei Ihrer Stadtverwaltung, den örtlichen Müllentsorgungsbetrieben oder im Geschäft, in dem Sie das Gerät erworben haben.

Page 91: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Appendix B Regulatory Compliance and Safety 91

Greek Notice

Hungarian Notice

. ,

.

.

,

,

.

Készülékek magánháztartásban történ selejtezése az Európai Unió területén

A készüléken, illetve a készülék csomagolásán látható azonos szimbólum annak

jelzésére szolgál, hogy a készülék a selejtezés során az egyéb háztartási

hulladéktól eltér módon kezelend . A vásárló a hulladékká vált készüléket köteles

a kijelölt gy jt helyre szállítani az elektromos és elektronikai készülékek

újrahasznosítása céljából. A hulladékká vált készülékek selejtezéskori begy jtése

és újrahasznosítása hozzájárul a természeti er források meg rzéséhez, valamint biztosítja

a selejtezett termékek környezetre és emberi egészségre nézve biztonságos feldolgozását.

A begy jtés pontos helyér l b vebb tájékoztatást a lakhelye szerint illetékes önkormányzattól,

az illetékes szemételtakarító vállalattól, illetve a terméket elárusító helyen kaphat.

Page 92: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

92 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Italian Notice

Latvian Notice

Smaltimento delle apparecchiature da parte di privati nel territorio dell'Unione Europea

Questo simbolo presente sul prodotto o sulla sua confezione indica che il prodotto non può essere smaltito insieme ai rifiuti domestici. È responsabilità dell'utente smaltire le apparecchiature consegnandole presso un punto di raccolta designato al riciclo e allo smaltimento di apparecchiature elettriche ed elettroniche. La raccolta differenziata e il corretto riciclo delle apparecchiature da smaltire permette di proteggere la salute degli individui e l'ecosistema. Per ulteriori informazioni relative

ai punti di raccolta delle apparecchiature, contattare l'ente locale per lo smaltimento dei rifiuti, oppure il negozio presso il quale è stato acquistato il prodotto.

Nolietotu iek rtu izn cin šanas noteikumi lietot jiem Eiropas Savien bas priv taj s m jsaimniec b s

Š ds simbols uz izstr d juma vai uz t iesai ojuma nor da, ka šo

izstr d jumu nedr kst izmest kop ar citiem sadz ves atkritumiem. J s

atbildat par to, lai nolietot s iek rtas tiktu nodotas speci li iek rtotos

punktos, kas paredz ti izmantoto elektrisko un elektronisko iek rtu

sav kšanai otrreiz jai p rstr dei. Atseviš a nolietoto iek rtu sav kšana un

otrreiz j p rstr de pal dz s saglab t dabas resursus un garant s, ka š s iek rtas tiks

otrreiz ji p rstr d tas t d veid , lai pasarg tu vidi un cilv ku vesel bu. Lai uzzin tu, kur

nolietot s iek rtas var izmest otrreiz jai p rstr dei, j v ršas savas dz ves vietas

pašvald b , sadz ves atkritumu sav kšanas dienest vai veikal , kur izstr d jums tika

nopirkts.

Page 93: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Appendix B Regulatory Compliance and Safety 93

Lihuanian Notice

Polish Notice

Nolietotu iek rtu izn cin šanas noteikumi lietot jiem Eiropas Savien bas priv taj s m jsaimniec b s

Š ds simbols uz izstr d juma vai uz t iesai ojuma nor da, ka šo

izstr d jumu nedr kst izmest kop ar citiem sadz ves atkritumiem. J s

atbildat par to, lai nolietot s iek rtas tiktu nodotas speci li iek rtotos

punktos, kas paredz ti izmantoto elektrisko un elektronisko iek rtu

sav kšanai otrreiz jai p rstr dei. Atseviš a nolietoto iek rtu sav kšana un

otrreiz j p rstr de pal dz s saglab t dabas resursus un garant s, ka š s iek rtas tiks

otrreiz ji p rstr d tas t d veid , lai pasarg tu vidi un cilv ku vesel bu. Lai uzzin tu, kur

nolietot s iek rtas var izmest otrreiz jai p rstr dei, j v ršas savas dz ves vietas

pašvald b , sadz ves atkritumu sav kšanas dienest vai veikal , kur izstr d jums tika

nopirkts.

Pozbywanie si zu ytego sprz tu przez u ytkowników w prywatnych gospodarstwach domowych w Unii Europejskiej

Ten symbol na produkcie lub jego opakowaniu oznacza, e produktu nie wolno

wyrzuca do zwykłych pojemników na mieci. Obowi zkiem u ytkownika jest

przekazanie zu ytego sprz tu do wyznaczonego punktu zbiórki w celu recyklingu

odpadów powstałych ze sprz tu elektrycznego i elektronicznego. Osobna zbiórka

oraz recykling zu ytego sprz tu pomog w ochronie zasobów naturalnych

i zapewni ponowne wprowadzenie go do obiegu w sposób chroni cy zdrowie człowieka

i rodowisko. Aby uzyska wi cej informacji o tym, gdzie mo na przekaza zu yty sprz t do

recyklingu, nale y si skontaktowa z urz dem miasta, zakładem gospodarki odpadami lub

sklepem, w którym zakupiono produkt.

Page 94: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

94 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Portuguese Notice

Slovakian Notice

Descarte de Lixo Elétrico na Comunidade Européia

Este símbolo encontrado no produto ou na embalagem indica que o produto não deve ser descartado no lixo doméstico comum. É responsabilidade do cliente descartar o material usado (lixo elétrico), encaminhando-o para um ponto de coleta para reciclagem. A coleta e a reciclagem seletivas desse tipo de lixo ajudarão a conservar as reservas naturais; sendo assim, a reciclagem será feita de uma forma segura, protegendo o ambiente e a saúde das pessoas. Para obter

mais informações sobre locais que reciclam esse tipo de material, entre em contato com o escritório da HP em sua cidade, com o serviço de coleta de lixo ou com a loja em que o produto foi adquirido.

Page 95: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Appendix B Regulatory Compliance and Safety 95

Slovenian Notice

Spanish Notice

Eliminación de residuos de equipos eléctricos y electrónicos por parte de usuarios particulares en la Unión Europea

Este símbolo en el producto o en su envase indica que no debe eliminarse junto con los desperdicios generales de la casa. Es responsabilidad del usuario eliminar los residuos de este tipo depositándolos en un "punto limpio" para el reciclado de residuos eléctricos y electrónicos. La recogida y el reciclado selectivos de los residuos de aparatos eléctricos en el momento de su eliminación contribuirá a conservar los recursos naturales y a garantizar el reciclado de estos residuos

de forma que se proteja el medio ambiente y la salud. Para obtener más información sobre los puntos de recogida de residuos eléctricos y electrónicos para reciclado, póngase en contacto con su ayuntamiento, con el servicio de eliminación de residuos domésticos o con el establecimiento en el que adquirió el producto.

Page 96: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

96 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Swedish Notice

Bortskaffande av avfallsprodukter från användare i privathushåll inom Europeiska Unionen

Om den här symbolen visas på produkten eller förpackningen betyder det att produkten inte får slängas på samma ställe som hushållssopor. I stället är det ditt ansvar att bortskaffa avfallet genom att överlämna det till ett uppsamlingsställe avsett för återvinning av avfall från elektriska och elektroniska produkter. Separat insamling och återvinning av avfallet hjälper till att spara på våra naturresurser och gör att avfallet återvinns på ett sätt som skyddar människors hälsa och miljön.

Kontakta ditt lokala kommunkontor, din närmsta återvinningsstation för hushållsavfall eller affären där du köpte produkten för att få mer information om var du kan lämna ditt avfall för återvinning.

Page 97: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

97

Index

Aaccessing

SMU, 46

the CLI, 42

accumulators, 84

Avis Canadien, regulatory compliance

notice, 81

Bbatteries

recycling or disposal, 84

replacement

notice, 84

Taiwan EPA recycling and disposal, 84

boot straps, using, 86

BSMI, regulatory compliance notice, 82

Ccables

FCC compliance statement, 74, 79

shielded, 74, 79

cabling

routing requirements, 73

Canada, regulatory compliance notice, 81

certification and classification information, laser, 81

Class A equipment, Canadian compliance statement, 81

Class B equipment, Canadian compliance statement, 82

clearance requirements

service, 73

ventilation, 73

CLI, See command-line interface

command-line interface

about, 12

accessing, 42

using to set controller IP addresses, 42

configuring

direct attach configurations, 40

SMU, 46

storage, first time, 41

connecting

AC power, 36

controller and drive enclosures, 33

controller enclosures to data hosts, 40

serial cable to set IP address, 42

to remote management hosts, 40

using reverse cabling, 33

console requirement, 74

controller enclosures

components, 13

connecting to data hosts, 40

connecting to multiple drive enclosures, 33

connecting to remote management hosts, 40

controller modules

LEDs

cache status, 18, 19

Ethernet activity, 20

Ethernet link status, 19

expansion port status, 20

Fault/Service Required, 18

host activity, 19

host link status, 17

OK, 18

OK to Remove, 18

Unit Locator, 18

location, 16

ports

CLI, 16

Ethernet, 16

expansion, 16

host, 16

service, 16

cooling element

fan sensor descriptions, 67

cord. See power cord

current rating, 85

Page 98: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

98 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

Ddata hosts

connecting to controller enclosures

mapping to volumes, 50

system requirements, 39

date and time, setting, 47

declaration of conformity, 78

DHCP

obtaining IP addresses, 38

dimensions, 74

direct attach configurations, 40

disposal

waste equipment for EU private households, 88

disposal, battery, 84

disposal, Taiwan EPA battery, 84

dissipating floor mats, 86

drive enclosures

components, 20

connecting to controller enclosures, 33

connecting to other drive enclosures, 33

LEDs

Fault/Service Required, 23

OK, 23

OK to Remove, 22

SAS In port status, 22

SAS Out port status, 23

Unit Locator, 22

location, 21

ports

SAS In, 21

SAS Out, 21

service, 21

drive modules

LEDs, 15

location, 14

numbering, 14

Eear caps, attaching, 32

electrical requirements, 76

electromagnetic compatibility (EMC), 71

electrostatic damage prevention, 85

enclosure

attaching ear caps, 32

cabling configurations, 33

dimensions, 74

electrical requirements, 76

IDs, correcting, 55

input frequency requirement, 76

input voltage requirement, 76

installation checklist, 27

powering on, 37

site requirements, 74

testing connections, 37

troubleshooting, 55

weight, 74

environmental requirements, 75

ESD (electrostatic discharge)

prevention measures, 85

storing products, 85

transporting products, 85

European Union, regulatory compliance

notice, 82

expansion port LED, 64

Ffault tolerance

cabling configuration, 33, 34

reverse cabling, 33

faults

isolating

a host-side connection, 63

expansion port connection fault, 64

methodology, 53

FCC (Federal Communications Commission)

Class A Equipment, compliance notice, 77

Class B Equipment, compliance notice, 78

declaration of conformity, 78

modifications, 79

notice, 77

Federal Communications Commission. See FCC

firmware

update information, 47

viewing version information, 47

floor mats, dissipating, 86

Gground strap specifications, 86

grounding

methods, 86

straps, wearing, 86

suggested equipment for, 86

Page 99: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Index 99

Hheartbeat

LED, 14

heel straps, using, 86

help, obtaining, 10

hosts, See data hosts

HP

address for

FCC questions, 78

series number, 79

telephone number

FCC questions, 78

humidity operating range, 75

HyperTerminal settings, See terminal emulator

IIDs, correcting for enclosure, 55

IEC EMC, worldwide regulatory compliance notice, 81

indicators, See LEDs

installing enclosures

checklist, 27

safety precautions, 26

installing required host software and drivers

SES driver, 40

IP addresses

setting using DHCP, 38

setting using the CLI, 42

JJapan

regulatory compliance notice, 83

KKorean, regulatory compliance notice, 83

Llabel, laser, 81

laser

international certification and classification

information, 81

product label, 81

radiation, warning, 80

regulatory compliance notice, 80

LEDs

AC Power Good, 17, 22

amber fault conditions, 56

cache status, 18, 19

DC Voltage/Fan Fault/Service Required, 17, 22

drive modules, 15

Enclosure ID, 14

Ethernet activity, 20

Ethernet link status, 19

expansion port status, 20

Fault/Service Required, 18, 23

heartbeat, 14

host activity, 19

host link status, 17

OK, 18, 23

OK to Remove, 18, 22

SAS In port status, 22

SAS Out port status, 23

status, 14

Unit identification (UID), 14

Unit Locator, 18, 22

using to diagnose fault conditions, 56

lithium battery, 84

local management host requirement, 74

Mmanaging storage systems

using SMU, 12

using the CLI, 12

mapping, data hosts to volumes, 50

MPIO DSM, obtaining, 39

Ooperating ranges, environmental, 75

Pparts

proper handling, 86

storing, 85

transporting, 85

physical requirements, 74

ports

CLI, 16

Ethernet, 16

expansion, 16

host, 16

SAS In, 21

SAS Out, 21

service, 16, 21

power

Page 100: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

100 HP StorageWorks 2012sa Modular Smart Array user guide • May 2008

connecting AC, 36

power cord

compliance notice, 85

current rating, 85

replacement, 85

set, 85

voltage rating, 85

power cord requirements, 76

power-and-cooling modules

LEDs, 16

AC Power Good, 17, 22

DC Voltage/Fan Fault/Service Required, 17, 22

power switches, 21

voltage sensor descriptions, 69

preventing electrostatic damage, 85

Rracks

preparing, 28

recycling, battery, 84

recycling, Taiwan EPA battery, 84

regulatory compliance

information number, 79

notices

BSMI, 82

Canada, 81

Class A, 77

Class B, 78

European Union, 82

HP series number, 79

IEC EMC statement, worldwide, 81

Japan, 83

Korean, 83

lasers, 80

modifications, 79

shielded cables, 74, 79

remote management, 40

replacing a power cord, 85

requirements

host system, 39

RFI/EMI connector hoods, 74, 79

Ssafety precautions, 26, 71

sensors

cooling fan, 67

locating, 66

power supply, 67

temperature, 68

voltage, 69

series number, regulatory compliance, 79

SES driver, installing on data hosts, 40

shock operating range, 75

site planning

electrical requirements, 76

EMC, 71

enclosure weight and dimensions, 74

environmental requirements, 75

local management host requirement, 74

physical requirements, 74

safety precautions, 71

SMU

about, 12

configuring, 46

creating virtual disks, 48

logging in, 46

logging out, 51

setting date and time, 47

testing system configuration, 50

static-dissipating work mat, 86

static-safe containers

storing products, 85

transporting products, 85

status LEDs, 14

Storage Management Utility, See SMU

storage system

configuring for the first time, 41

environmental requirements, 75

powering on, 37

testing configuration, 50

storage website, 10

straps, ground

boot, 86

heel, 86

toe, 86

Subscriber’s choice website, 10

Subscriber’s choice, HP, 10

TTaiwan EPA battery recycling and disposal, 84

telephone numbers

FCC questions, 78

temperature operating range, 75

Page 101: HP StorageWorks 2012sa Modular Smart Array user guidebaushop24.oslo.sylon.net/shop/img/documents/msa2000 (1).pdf · Information about using SMU is in its online help and in the reference

Index 101

terminal emulator

connection settings, 43

display settings, 43

toe straps, using, 86

tools required for installation, 25

tools, conductive type, 86

troubleshooting, 64

correcting enclosure IDs, 55

using system LEDs, 56

UUID LED, 14

Unit identification (UID) LED, 14

Vventilation requirements, 73

vibration operating range, 75

virtual disks

creating, 48

viewing status, 50

voltage compliance rating, 85

volumes

mapping data hosts, 50

verifying, 50

Wwarnings

lasers, radiation, 80

waste equipment disposal for EU private households, 88

web-browser configuration, 46

websites

HP storage, 10

HP Subscriber’s choice, 10

weight, 74

work mat, static-dissipating, 86

wrist straps

specifications, 86

using, 86