Honeywell Test & Measurement - Load Cells

248
Load Cell Model 101 FEATURES 50 kg to 1000 kg range ±0.02 % accuracy Integral cable Cost efficient One-piece, nickel-plated alloy steel construction DESCRIPTION Model 101 load cells is engineered to measure bending forces and still achieve an impressive 0.02 % accuracy. Small dimensions allow easy unit integration into existing systems. Model 101 uses foil gages and is available for load ranges from 50 grams to 1000 pounds. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Transcript of Honeywell Test & Measurement - Load Cells

Load CellModel 101

FEATURES• 50kgto1000kgrange

• ±0.02%accuracy

• Integralcable

• Costefficient

• One-piece,nickel-platedalloysteelconstruction

DESCRIPTIONModel101loadcellsisengineeredtomeasurebending

forcesandstillachieveanimpressive0.02%accuracy.Small

dimensionsalloweasyunitintegrationintoexistingsystems.

Model101usesfoilgagesandisavailableforloadrangesfrom

50gramsto1000pounds.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 101

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadranges3 50,100,250,500,1000kg

Accuracy ±0.02%fullscale

Output 2mV/V(nominal)

Creep(max.) ±0.02%fullscale(30minutes)

RANGE CODES

Range Codes Range

LF 50kg

LH 100kg

LL 250kg

LN 500kg

LQ 1000kg

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bondedfoil

Excitation(calibration) 10Vdcto12Vdc

Excitation(max.) 15Vdc

Insulationresistance >5000mOhm

Bridgeresistance(toler-ance)-inputresistance

400ohm±10ohm(nominal)

Bridgeresistance(toler-ance)-outputresistance

352ohm±2ohm(nominal)

Zerobalance(tolerance) ±1%fullscale

Electricaltermination(std) 3mflyingleads

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximumallowableload 150%fullscale1

Material Nickelplatedalloysteel

Deflection <2mm

WIRING CODES

Cable

Red (+)supply

Black (-)supply

Green (+)output

White (-)output

Large black shield

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature,operating -30°Cto70°C[-22°Fto158°F]

Temperature,compensated -20°Cto55°C[-4°Fto130°F]

Temperatureeffect,zero 0.02%fullscale/10°C

Temperatureeffect,span 0.02%fullscale/10°C

MOUNTING DIMENSIONS

Load (kg) H mm [in] Recommended bolt torque (N-m)

50to2250 18[0.71] 60

500,1000 24[0.94] 60

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008674-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 101 Load Cell

NOTES

1. Allowablemaximumloads–maximumloadtobeappliedwithoutdamage2.

2. Withoutdamage-loadingtothislevelwillnotcauseexcessivezeroshiftofperformancedegradation.Theusermustconsiderfatiguelifeforlongtermuseandstructuralintegrity.Allstructurallycriticalapplications(overheadloading,etc.)shouldalwaysbedesignedwithsafetyredundantloadpaths.

3. ThisunitiscalibratedtoMetric(non-Imperial)units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Load CellModel 102

DESCRIPTIONThe Model 102 load cells combines both a compact form and

high precision to offer a superior tension force transducer. The

one-piece S-shaped design achieves a maximum non-linearity

of 0.02 % full scale for load ranges from 20 kg to 1000 kg.

Additional features include minimal temperature effects on zero

and span of 0.002 %/°C and 0.002 %/°C, respectively.

FEATURES• 20kgto1000kgrange

• ±0.02%accuracy

• One-piece,nickel-platedalloysteelconstruction

• Integralcable

• Costefficient

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 102

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges3 20, 50, 100, 200, 300, 500, 1000 kg

Accuracy ±0.02%fullscale

Output 2.0 mV/V

Creep (max.) ±0.02%fullscale(30minutes)

RANGE CODES

Range codes Range

LD 20 kg

LE 30 kg

LF 50 kg

LG 75 kg

LH 100 kg

LJ 150 kg

LK 200 kg

LL 250 kg

LM 300 kg

LN 500 kg

LQ 1000 kg

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bonded foil

Excitation (acceptable) 10 Vdc to 12 Vdc

Excitation (max.) 15 Vdc

Insulationresistance >5000mOhm

Bridge resistance (toler-ance)-Inputresistance

400ohm±10ohm(nominal)

Bridge resistance (toler-ance)-Outputresistance

352ohm±2ohm(nominal)

Zero balance (tolerance) ±1%fullscale

Electrical termination (std) 3 m [9.84 ft] flying leads

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 150 full scale1

Material Nickel plated alloy steel or stainless steel

Deflection Less than or equal to 0,5 mm [0.02 in]

WIRING CODES

Cable

Red (+) supply

Black (-) supply

Green (+) output

White (-) output

Large Black Shield

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -30 °C to 70 °C [-22 °F to 158 °F]

Temperature, compensated -20 °C to 55 °C [-4 °F to 131 °F]

Temperature effect, zero ±0.02%fullscale/10°C

Temperature effect, span ±0.02%fullscale/10°C

Protection class IP67

MOUNTING DIMENSIONS

Load D (thread) L

20 kg to 150 kg M8 x 1.25 12 mm [0.47 in]

200 kg to 500 kg M12 x 1.75 20 mm [0.79 in]

700 kg to 1000 kg M12 x 1.75 25 mm [0.98 in]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008662-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 102 Load Cell

TYPICAL SYSTEM DIAGRAM

NOTES

1. Allowable maximum loads – maximum load to be applied without damage.2

2. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

3. ThisunitiscalibratedtoMetric(non-Imperial)units.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your orderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywell during the period of coverage, Honeywell will repair orreplace,atitsoption,withoutchargethoseitemsitfindsdefective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Load CellModel 103

FEATURES• Lowcost

• 100kgto10000kgrange

• ±0.02%accuracy

• Integralcable

• Costefficient

• One-piece,nickel-platedalloysteelconstruction

DESCRIPTIONModel103loadcellisengineeredtomeasurebendingforces

andstillachieveanimpressive0.02%fullscaleaccuracy.Small

dimensionsalloweasyunitintegrationintoexistingsystems.

Model103usesfoilgagesandisavailableforloadrangesfrom

100kgto10000kg.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 103

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadranges3 100,200,300,500,1000,2000,3000,5000,10000kg

Accuracy ±0.02%fullscale

Output 2mV/V(nominal)

Creep(max.) ±0.02%fullscale(30minutes)

RANGE CODES

Range Codes Range

LH 100kg

LL 250kg

LM 300kg

LN 500kg

LQ 1000kg

LS 2000kg

LU 5000kg

LW 10000kg

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bondedfoil

Excitation(calibration) 10Vdcto12Vdc

Excitation(max.) 15Vdc

Insulationresistance >5000mOhm

Bridgeresistance(toler-ance)-inputresistance

400ohm±10ohm(nominal)

Bridgeresistance(toler-ance)-outputresistance

352ohm±2ohm(nominal)

Zerobalance(tolerance) ±1%fullscale

Electricaltermination(std)100kgto300kg

3mflyingleads

Electricaltermination(std)1000kgto5000kg

5mflyingleads

Electricaltermination(std)10000kg

8mflyingleads

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximumallowableload 150%fullscale1

Material Nickelplatedalloysteel

Deflection <1,5mm

WIRING CODES

Cable

Red (+)supply

Black (-)supply

Green (+)output

White (-)output

Large black shield

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature,operating -30°Cto70°C[-22°Fto158°F]

Temperature,compensated -20°Cto55°C[-4°Fto130°F]

Temperatureeffect,zero ±0.02%fullscale/10°C

Temperatureeffect,span ±0.02%fullscale/10°CTYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Load Cell

MOUNTING DIMENSIONS

Load (kg)

A mm [in]

B mm [in]

C mm [in]

D mm [in]

E mm [in]

F mm [in]

G mm [in]

H mm [in]

L mm [in]

M mm [in]

Recom-mended bolt torque (N-m)

100to300

135[5.31] 36[1.42] 26[1.02] 18[0.71] 75[2.95] 25[1.0] 32[1.26] 58[2.28] 11,5[0.45]

11,5[0.45]

60

500to2000

135[5.31] 38[1.5] 30[1.18] 18[0.71] 75[2.95] 25[1.0] 34[1.34] 58[2.28] 13,5[0.53]

13,5[0.53]

100

300to5000

170[6.69] 48[1.89] 38[1.5] 20[0.79] 85[3.35] 50[2.0] 39[1.54] 79[3.11] 18[0.71] 18,5[0.73]

255

10000 263[10.35]

60[2.36] 60[2.36] 30[1.18] 118[4.65] 90[3.54] 52[2.05] 134[5.28] 26[1.02] 26[1.02] 860

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008675-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 103 Load Cell

NOTES

1. Allowablemaximumloads–maximumloadtobeappliedwithoutdamage2.

2. Withoutdamage-loadingtothislevelwillnotcauseexcessivezeroshiftofperformancedegradation.Theusermustconsiderfatiguelifeforlongtermuseandstructuralintegrity.Allstructurallycriticalapplications(overheadloading,etc.)shouldalwaysbedesignedwithsafetyredundantloadpaths.

3. ThisunitiscalibratedtoMetric(non-Imperial)units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Load CellModel 123

FEATURES• 1000kgto20000kgrange

• ±0.03%accuracy

• Built-inoverloadresistance

• One-piece,nickel-platedalloysteelconstruction

• Integralcable

• Costefficient

DESCRIPTIONTheModel123loadcellscombinesbothacompactformand

highprecisiontoofferasuperiortensionforcetransducer.The

one-pieceS-shapeddesignachievesamaximumnon-linearityof

0.03%fullscaleforloadrangesfrom1000kgto20000kg.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 123

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadranges4 1000kgto20000kg

Accuracy ±0.03%fullscale

Output 2.0mV/V

Creep(max.) ±0.03%fullscale(30minutes)

RANGE CODES

Range codes Range

LQ 1000kg

LR 1500kg

LS 2000kg

LT 3000kg

LU 5000kg

LV 7500kg

LW 10000kg

LY 15000kg

LZ 20000kg

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation(acceptable) 10Vdcto12Vdc

Excitation(max.) 15Vdc

Insulationresistance >5000mOhm

Bridgeresistance(toler-ance)-Inputresistance

400ohm±10ohm(nominal)

Bridgeresistance(toler-ance)-Outputresistance

352ohm±2ohm(nominal)

Zerobalance(tolerance) ±1%fullscale

Electricaltermination(std) 6m[19.69ft]of5mm[0.2in]diametercable

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximumallowableload 120%fullscale1

Laterloadlimit 100%fullscale

Material Nickelplatedalloysteel

WIRING CODES

Cable

Red (+)supply

Black (-)supply

Green (+)output

White (-)output

Large Black Shield

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature,operating -30°Cto70°C[-22°Fto158°F]

Temperature,compensated -20°Cto55°C[-4°Fto131°F]

Temperatureeffect,zero ±0.03%fullscale/10°C

Temperatureeffect,span ±0.03%fullscale/10°C

Protectionclass IP673 MOUNTING DIMENSIONS

Range (kg) A B C D

1000,1500 80mm[3.15in]

70mm[2.76in]

25mm[0.98in]

M12x1.75

2000,3000,5000

108mm[4.25in]

95mm[3.75in]

25mm[0.98in]

M18x1.5

7500,10000 178mm[7.00in]

130mm[5.12in]

51mm[2.0in]

M30x2

15000,20000 190mm[7.48in]

160mm[6.3in]

60mm[2.36in]

M30x2

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008663-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 123 Load Cell

TYPICAL SYSTEM DIAGRAM

NOTES

1. Allowablemaximumloads–maximumloadtobeappliedwithoutdamage.2

2. Withoutdamage-loadingtothislevelwillnotcauseexcessivezeroshiftorperformancedegradation.Theusermustconsiderfatiguelifeforlongtermuseandstructuralintegrity.Allstructurallycriticalapplications(overheadloading,etc.)shouldalwaysbedesignedwithsafetyredundantloadpaths.

3. IP68ratingforloadranges7500kgandgreater.4. ThisunitiscalibratedtoMetric(non-Imperial)units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Load CellModel 125

FEATURES• 100kgto500kgrange

• ±0.02%accuracy

• One-piece,nickel-platedalloysteelconstruction

• Matingconnectorand5mcableincluded

• Costefficient

DESCRIPTIONTheModel125loadcellscombinesbothacompactformand

highprecisiontoofferasuperiortensionforcetransducer.The

one-pieceS-shapeddesignachievesamaximumnon-linearityof

0.03%fullscaleforloadrangesfrom100kgto500kg.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 125

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadranges3 100,200,300,500kg

Accuracy ±0.02%fullscale

Output 2.0mV/V

Creep(max.) ±0.02%fullscale(30minutes)

RANGE CODES

Range codes Range

LH 100kg

LK 200kg

LM 300kg

LN 500kg

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bondedfoil

Excitation(acceptable) 10Vdcto12Vdc

Excitation(max.) 15Vdc

Insulationresistance >5000mOhm

Bridgeresistance(toler-ance)-Inputresistance

400ohm±10ohm(nominal)

Bridgeresistance(toler-ance)-Outputresistance

352ohm±2ohm(nominal)

Zerobalance(tolerance) ±1%fullscale

Electricaltermination(std) Matingconnectorand5m[16.40ft]cable(included)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximumallowableload 150%FS1

Material Nickelplatedalloysteel

WIRING CODES

Cable

Red (+)supply

Black (-)supply

Green (+)output

White (-)output

Large Black Shield

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature,operating -30°Cto70°C[-22°Fto158°F]

Temperature,compensated -20°Cto55°C[-4°Fto131°F]

Temperatureeffect,zero ±0.02%fullscale/10°C

Temperatureeffect,span ±0.02%fullscale/10°C

Protectionclass IP67

MOUNTING DIMENSIONS

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008665-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 125 Load Cell

TYPICAL SYSTEM DIAGRAM

NOTES

1. Allowablemaximumloads–maximumloadtobeappliedwithoutdamage.2

2. Withoutdamage-loadingtothislevelwillnotcauseexcessivezeroshiftorperformancedegradation.Theusermustconsiderfatiguelifeforlongtermuseandstructuralintegrity.Allstructurallycriticalapplications(overheadloading,etc.)shouldalwaysbedesignedwithsafetyredundantloadpaths.

3. ThisunitiscalibratedtoMetric(non-Imperial)units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Load CellModel 127

FEATURES• 50kg,100kgrange

• ±0.03%FSaccuracy

• Built-inoverloadresistance

• One-piece,nickel-platedalloysteelconstruction

• Integralcable

• Costefficient

DESCRIPTIONTheModel127loadcellscombinesbothacompactformand

highprecisiontoofferasuperiortensionforcetransducer.The

one-pieceS-shapeddesignachievesamaximumnon-linearityof

0.03%fullscaleforloadrangesof50kgand100kg.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 127

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadranges3 50kg,100kg

Accuracy ±0.03%fullscale

Output 3.0mV/V

Creep(max.) ±0.03%fullscale(30minutes)

RANGE CODES

Range codes Range

LF 50kg

LH 100kg

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bondedfoil

Excitation(acceptable) 10Vdcto12Vdc

Excitation(max.) 15Vdc

Insulationresistance >5000mOhm

Bridgeresistance(toler-ance)-Inputresistance

400ohm±10ohm(nominal)

Bridgeresistance(toler-ance)-Outputresistance

352ohm±2ohm(nominal)

Zerobalance(tolerance) ±1%fullscale

Electricaltermination(std) 5m[16.40ft]flyingleads

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximumallowableload 150%fullscale1

Material Nickelplatedalloysteel

WIRING CODES

Cable

Red (+)supply

Black (-)supply

Green (+)output

White (-)output

Large Black Shield

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature,operating -30°Cto70°C[-22°Fto158°F]

Temperature,compensated -20°Cto55°C[-4°Fto131°F]

Temperatureeffect,zero ±0.03%fullscale/10°C

Temperatureeffect,span ±0.03%fullscale/10°C

Protectionclass IP67

MOUNTING DIMENSIONS

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008664-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 127 Load Cell

TYPICAL SYSTEM DIAGRAM

NOTES

1. Allowablemaximumloads–maximumloadtobeappliedwithoutdamage.2

2. Withoutdamage-loadingtothislevelwillnotcauseexcessivezeroshiftorperformancedegradation.Theusermustconsiderfatiguelifeforlongtermuseandstructuralintegrity.Allstructurallycriticalapplications(overheadloading,etc.)shouldalwaysbedesignedwithsafetyredundantloadpaths.

3. ThisunitiscalibratedtoMetric(non-Imperial)units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Load CellModel 129

FEATURES• 1000kgto5000kgrange

• ±0.02%accuracy

• One-piece,nickel-platedalloysteelconstruction

• Integralcable

• Costefficient

DESCRIPTIONTheModel129loadcellscombinesbothacompactformand

highprecisiontoofferasuperiortensionforcetransducer.The

one-pieceS-shapeddesignachievesamaximumnon-linearityof

0.02%fullscaleforloadrangesfrom1000kgto5000kg.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 129

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadranges3 1000,2000,3000,5000kg

Accuracy ±0.02%fullscale

Output 2.0mV/V

Creep ±0.02%fullscale(30minutes)

RANGE CODES

Range codes Range

LQ 1000kg

LS 2000kg

LY 3000kg

LU 5000kg

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bondedfoil

Excitation(acceptable) 10Vdcto12Vdc

Excitation(max.) 15Vdc

Insulationresistance >5000mOhm

Bridgeresistance(toler-ance)-Inputresistance

400ohm±10ohm(nominal)

Bridgeresistance(toler-ance)-Outputresistance

352ohm±2ohm(nominal)

Zerobalance(tolerance) ±1%fullscale

Electricaltermination(std) 5m[16.40ft]flyingleads

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximumallowableload 150%FS1

Material Nickelplatedalloysteel

WIRING CODES

Cable

Red (+)supply

Black (-)supply

Green (+)output

White (-)output

Large Black Shield

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature,operating -30°Cto70°C[-22°Fto158°F]

Temperature,compensated -20°Cto55°C[-4°Fto131°F]

Temperatureeffect,zero ±0.02%fullscale/10°C

Temperatureeffect,span ±0.02%fullscale/10°C

Protectionclass IP67

MOUNTING DIMENSIONS

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008666-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 129 Load Cell

TYPICAL SYSTEM DIAGRAM

NOTES

1. Allowablemaximumloads–maximumloadtobeappliedwithoutdamage.2

2. Withoutdamage-loadingtothislevelwillnotcauseexcessivezeroshiftorperformancedegradation.Theusermustconsiderfatiguelifeforlongtermuseandstructuralintegrity.Allstructurallycriticalapplications(overheadloading,etc.)shouldalwaysbedesignedwithsafetyredundantloadpaths.

3. ThisunitiscalibratedtoMetric(non-Imperial)units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Low Cost Load CellModel 53

DESCRIPTIONModel 53 load cells are bonded foil strain gage transducers

designed for cost efficient production and testing applications

(i.e. press calibration). Engineered compression force

measurements up to 50000 lb., this model achieves a maximum

non-linearity of 0.25 % full scale. Precision gaging techniques

and a stainless steel construction provides excellent long-

term stability and reliability under severe operating conditions.

The Model 53 compression-only load cell has an integral load

button machined as part of the load cell. The Model 53 must be

mounted on a smooth flat surface for proper operation. Three

tapped holes are provided for mounting.

FEATURES• 5lbto50000lb

• Stainlesssteel

• Minifootprint

• Button-styledesign

• mV/Voutput

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 53PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges5 5 lb to 50000 lb

Linearity (max.) ±0.25 % full scale

Hysteresis (max.) ±0.2 % full scale

Non-repeatability (max.) ±0.1 % full scale

Output (tolerance) 2mV/V(nominal)

Operation Compression

Resolution Infinite

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bondedfoil

Excitation (calibration) 5 lb to 100 lb

5Vdc

Excitation (calibration)250 lb to 50000 lb

10Vdc

Insulation resistance 5000mOhm@50Vdc

Bridgeresistance(toler-ance)

350 ohm (nominal)

Zero balance (tolerance) ±3 % full scale

Shuntcalibrationdata Included

Electrical termination (std) Teflon cable 1.83 m [5 ft]

MECHANICAL SPECIFICATIONS

Characteristic Measure

Weight Seetable

Material 17-4 PH stainless steel

Maximum allowable load 150 % full scale1

Deflection full scale Seetable

Natural frequency Seetable

WIRING CODES

Cable Unamplified

Red (+) excitation

Black (-) excitation

Green (-) output

White (+) output

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb)

Deflection @ full scale (in)

Natural ring-ing frequency (Hz)

Weight with cable g [lb]

5 0.001 2000 59 [0.13]

10 0.001 3000 59 [0.13]

25 0.001 16000 62 [0.136]

50 0.001 21000 63 [0.138]

100 0.001 28000 64 [0.141]

250 0.001 25000 72 [0.158]

500 0.001 32000 72 [0.158]

1000 0.001 42000 75 [0.165]

2000 0.001 53000 77 [0.17]

3000 0.001 27000 137 [0.30]

4000 0.001 31000 138 [0.304]

5000 0.001 34000 140 [0.306]

7500 0.001 41000 142 [0.313]

10000 0.001 47000 145 [0.32]

15000 0.002 24000 368 [0.811]

20000 0.002 28000 372 [0.820]

30000 0.002 33000 377 [0.831]

50000 0.003 24000 1270 [2.8]

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto121°C[-65°Fto250°F]

Temperature, compensated 15°Cto71°C[60°Fto160°F]

Temperature effect, zero 0.005%fullscale/°F

Temperature effect, span 0.01%fullscale/°F

RANGE CODES

Range Code

Available ranges Range Code

Available ranges

AT 5 lb DN 3000 lb

AV 10 lb DP 4000 lb

BL 25 lb DR 5000 lb

BN 50 lb DT 7500 lb

BR 100 lb DV 10000 lb

CN 250 lb EJ 15000 lb

CR 500 lb EL 20000 lb

CV 1000 lb EN 30000 lb

DL 2000 lb EP 50000 lb

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Low Cost Load CellMOUNTING DIMENSIONS

Ranges lb D1 mm [in] D2 mm [in] H mm [in] L mm [in] A in B mm [in] G mm [in]

5, 10, 25, 50, 100 25,4 [1.00] 5,33 [0.21] 15,75 [0.62] 1,27 [0.05] #4-40UNC 5,59 [0.22] 19,05 [0.750]

250, 500, 1000, 2000 31,75 [1.25] 8,13 [0.32] 9,91 [0.39] 1,78 [0.07] #6-32UNC 6,35 [0.25] 25,4 [1.000]

3000, 4000, 5000, 7500, 10000

38,1 [1.50] 10,16 [0.40] 16,0 [0.63] 2,03 [0.08] #6-32UNC 6,35 [0.25] 31,75 [1.250]

15000, 20000, 30000 50,8 [2.00] 15,24 [0.60] 25,4 [1.00] 3,05 [0.12] #6-32UNC 6,35 [0.25] 41,28 [1.625]

50000 76,2 [3.00] 19,81 [0.78] 38,1 [1.50] 4,57 [0.18] #6-32UNC 6,35 [0.25] 60,33 [2.375]

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges

5, 10, 25, 50, 100, 250, 500, 1000, 2000, 3000, 4000, 5000, 7500, 10000, 15000, 20000, 30000, 50000 lb

Tempera-ture com-pensation

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F

1g.70°Fto325°F1h.70°Fto400°F1i.-65°Fto250°F1j.0°Cto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal amplifiers

2u.Unamplified,mV/Voutput

Electrical termination

6d.MicrotecDR-4S-4H4-pin6e. Integral cable: Teflon 6f.Integralcable:PVC6g. Integral cable: Neoprene

6h. Integral cable: Silicone

6i. Integral underwa-ter cable3

6v. Phoenix connector on end of cable

Special calibration

9a.10point(5up/5down)20%increments@68°F9b.20point(10up/10down)10%increments@68°F

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration6

53t.TEDSIEEE1451.4module4

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

008638-2-EN IL50 GLO January 2010Copyright © 2010 Honeywell International Inc. All rights reserved.

Model 53 Low Cost Load Cell

Sensing and Control

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422

www.honeywell.com

TYPICAL SYSTEM DIAGRAM

NOTES

1. Allowable maximum loads – maximum load to be applied without damage.2

2. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

3. Dimension“H”mayincreasewithoption6i.Consultfactory.Maxi-mumtemperatureis180°F.

4. TEDSavailablewithintegralcableunitsonly.5. This unit calibrated to Imperial (non-Metric) units.6. Signaturecalibrationonlyavailableasinlinemodule.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthisdatasheetisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.

•Completeinstallation,operationandmaintenanceinformation is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

Find out more

Honeywell serves its customers

through a worldwide network of

sales offices, representatives

anddistributors.Forapplication

assistance, current specifica-

tions, pricing or name of the

nearest Authorized Distributor,

contact your local sales office.

To learn more about Honeywell’s

test and measurement products,

call +1-614-850-5000, visit

www.honeywell.com/sensotec,

or e-mail inquiries to

[email protected]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Precision Low Profile Load CellModel 41

DESCRIPTIONModel 41 is a low profile “pancake” type load cells. These

bonded foil, strain gage load cells are engineered to measure

loads from 5 lb to 500,000 lb. The tension/ compression

Model 41 is designed with the threaded hole running completely

through the center of the cell. Model 41 utilizes two stabilizing

diaphragms, which are welded to the sensing member to

reduce off-center and side-loading effects. It provides high

performance in non-linearity, hysteresis, and repeatability speci-

fications for such applications as tube mills, extruding processes

and weighing. Each unit has a welded construction and can be

hermetically sealed for added durability. Model 41 load cells are

available with optional 0 Vdc to 5 Vdc or 4 mA to 20 mA output.

FEATURES• 0.1%accuracy

• 5lbto500000lb

• mV/Voutput(standard);4mAto20mAand0Vdcto5Vdc

(optional)outputs

• Doublediaphragmdesign

• Intrinsicallysafeavailable(2Noptiononly)16

• CEapproved17

Approved Approved ApprovedIntrinsically safe amp

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 41

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges18 5 lb to 500000 lb

Non-linearity,5lbto25lb ±0.2%fullscale

Hysteresis, 50 lb to 500000 lb

±0.1%fullscale

Hysteresis, 5 lb to 25 lb ±0.1%fullscale

Hysteresis, 50 lb to 500000 lb

±0.08%fullscale

Non-repeatability,5to25lb ±0.1%fullscale

Non-repeatability, 50 lb to 500000 lb

±0.03%fullscale

Output(tolerance),5 lb to 25 lb

2mV/V±0.5%fullscale

Output(tolerance),50 lb to 500000 lb

3mV/V±0.5%fullscale

Operation Compression/tension13

Resolution Infinite

Standardcalibration5-pointcalibration:0%,50%and100%offullscaleintensiononly

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto121°C[-65°Fto250°F]

Temperature, compensated 15°Cto71°C[60°Fto160°F]

Temperature effect, zero 0.002%fullscale/°F

Temperature effect, span 0.002%fullscale/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded foil

Excitation(calibration) 10 Vdc

Insulation resistance 5000 mOhm @ 50 Vdc

Bridge resistance (tolerance)

350ohm(nominal)

Zerobalance(tolerance) ±1%fullscale

Shuntcalibrationdata Included

Electricaltermination(std)5 lb to 5000 lb

PTIH-10-6P

Electricaltermination(std)7500 lb to 500000 lb

MS3102E-14S-6P

Mating connector 5lbto5000lb(notincl.)

PT06A-10-6Sorequiv.(AA111)

Mating connector 7500to500000lb(notincl.)

MS3106A-14S-6S(AA121)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 150%FS1

Weight Seetable

Material Less than 200,000 lb

17-4PH stainless steel

Material greater than or equalto300000lb

Carbonsteel

Deflection Seetable

Naturalfrequency Seetable

RANGE CODES

Range Code

Available ranges Range Code

Available ranges

AT 5 lb DV 10000 lb

AV 10 lb EJ 15000 lb

BL 25 lb EL 20000 lb

BN 50 lb EN 30000 lb

BR 100 lb EP 50000 lb

CN 250 lb ER 75000 lb

CR 500 lb ET 100000 lb

CV 1000 lb FJ 150000 lb

DL 2000 lb FL 200000 lb

DN 3000 lb FN 300000 lb

DP 4000 lb FP 400000 lb

DR 5000 lb FR 500000 lb

DT 7500 lb

WIRING CODES

Connector Unamplified (Std.)

A (+)excitation

B (+)excitation

C (-)excitation

D (-)excitation

E (-)output

F (+)output

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb) Deflection @ full scale (in)

Natural ringing frequency (Hz)

Weight (lb)

5 to 25 0.001 2000 0.8

50 to 1000 0.002 4600 1.5

2000 to 5000 0.002 10000 2.0

7500 to 15000 0.003 6000 8.8

20000 to 50000 0.004 8000 11.0

75000 to 100000 0.006 5500 30.9

150000 to 200000 0.010 4500 46.3

300000 to 500000 0.010 4100 130.1

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Precision Low Profile Load Cell

iNTERNAL AMPLIFIERS

Amplifier specifications

Voltage out-put: Option 2b

Voltage out-put: Option 2c

Voltage out-put: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Op-tion 2n (2N)***

Output signal ±5 V 0-5 V or ±5 V @ 45 mA

0-10 V or ±10 V @ 45 mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage) ±15 Vdc or 26-32 Vdc

11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc

9 Vdc to 28 Vdc

Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA

Freq. response 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rejection 60 db 60 db 60 db 60 db 60 db 60 db

Operating temperature -20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F

Reverse volt. protection Yes Yes Yes Yes Yes Yes

Short circuit protection Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector A(+)SupplyB Output commonCSupplyreturnD(+)OutputEShuntCal1FShuntCal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntCal1FShuntCal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntCal1FShuntCal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntCal1FShuntCal2

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

Wiring code: cable R(+)SupplyBl Output commonGSupplyreturnW(+)OutputBShuntCal1BrShuntCal2

R(+)SupplyBl Output com*GSupplyreturn*W(+)OutputBShuntCal1BrShuntCal2

R(+)SupplyBl Output com*GSupplyreturn*W(+)OutputBShuntCal1BrShuntCal2

R(+)SupplyBl Output com*GSupplyreturn*W(+)OutputBShuntCal1BrShuntCal2

R(+)SupplyBl(+)OutputWCaseground

R(+)SupplyBl(+)OutputWCaseground

* Black and green wires are internally connected.**PinsBandCareinternallyconnected.***SeeourWebsiteforthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.

ALLOWABLE MAXIMUM LOADS

Capacity (lb) Side load (lb)

Bending (lb-in)

Torque (lb-ft)

5 to 25 50% 40% 25%

50 to 1000 45% 35% 25%

2000 to 5000 30% 25% 25%

7500 to 30000 20% 20% 15%

50000 to 100000 20% 20% 15%

150000 to 200000 20% 20% 15%

300000 20% 20% 10%

400000 20% 20% 10%

500000 20% 20% 10%

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model 41

OPTION CODES

Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 5, 10, 25, 50, 100, 250, 500, 1000, 2000, 5000, 3000, 4000, 7500, 10000, 15000, 20000, 30000, 50000, 75000, 100000, 150000, 200000, 300000, 400000, 500000 lb

Temperature compensation

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F

1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F

1g.70°Fto325°F14

1h.70°Fto400°F14

1i.-65°Fto250°F14

1j.0°Cto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal amplifiers 10

2b. 4 wire, ±5 Vdc2c. 0-5 Vdc output

2j.4-20mA(three-wire)output

2k.4mAto20mA(two-wire)20

2n(2N)4mAto20mA(wire)intrinsically safe20

2t. 0 Vdc to 10 Vdc

2u. Unamplified, mV/V output

Internal ampli-fier enhance-ments

3a. Input/output isolation19

3d. Remote buffered shunt calibratrion8

Overload stops

4a. Overload stops

Electrical termination

6a. Bendix PTIH-10-6P 6-pin (rangesto5000lb)

6b.MS3102E-14S-6P(rang-es7500lbandup)9

6e.Integralcable:Teflon

6f.Integralcable:PVC6g.Integralcable:Neo-

prene9

6h.Integralcable:Silicone

6i. Integral underwater cable9

6j. 1/2-14 conduit fitting with 5ftof4conductorPVCcable

6q.Moldedintegralcablepoly-urethane9

6v. Phoenix connector on end of cable

Shunt calibra-tion

8a. Precision internal resistor14

Special cali-bration

9a.10point(5up/5down)20%increments@68°F9b.20point(10up/10down)10%increments@68°F9c.ASTME-74calibration

Bridge resist-ance

12b.5000ohm(foil)

Zero and span adjustment

14a.Noaccesstopots14b. Top access to pots

Electrical con-nector orienta-tion

15a. Horizontal electrical exit port orientation15b. Vertical electrical exit port orientation

15c. Radial electrical exit port orientation15d.Connectoronendofcable

Special cali-bration

30a. Compression only calibration, positive in compression30b. Tension and compression calibration, positive in tension30c. Compression only calibration, negative in compression30d. Tension and compression calibration, positive in compression

Bridge type 31a.Dualbridge

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration14

53t.TEDSIEEE1451.4module15

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl5

Precision Low Profile Load Cell

MOUNTING DIMENSIONS

Ranges lb

D mm [in]

H mm [in]

H*** mm [in]

F# ØG mm [in] B.C.

ØK mm [in] thru

T A mm [in]

A* mm [in]

B mm [in]

B* mm [in]

C mm [in]

5, 10, 25 63,5 [2.50]

20,32 [0.80]

44,45 [1.75]

6 50,8 [2.000]

4,83 [0.19]

1/4-28 UNF

20,83 [0.82]

63,5 [2.5]

19,05 [0.75]

22,86 [0.9]

31,75 [1.25]

50, 100, 250, 500, 1000

76,2 [3.00]

25,4 [1.00]

44,45 [1.75]

6 57,15 [2.250]

7,11 [0.28]

3/8-24 UNF

20,83 [0.82]

63,5 [2.5]

19,05 [0.75]

22,86 [0.9]

31,75 [1.25]

2000, 3000, 4000, 5000

88,9 [3.50]

25,4 [1.00]

44,45 [1.75]

6 66,68 [2.625]

8,64 [0.34]

1/2-20 UNF

20,83 [0.82]

63,5 [2.5]

19,05 [0.75]

22,86 [0.9]

31,75 [1.25]

7500, 10000, 15000

139,7 [5.50]

45,7 [1.80]

45,7 [1.80]

8 114,3 [4.500]

10,16 [0.40]

1-14 UNS

31,75 [1.25]

58,42 [2.3]

38,1 [1.50]

38,1 [1.5]

50,8 [2.00}

20000, 30000, 50000

152,4 [6.00]

45,7 [1.80]

45,7 [1.80]

8 123,83 [4.875]

13,46 [0.53]

1 1/2-12 UNF

31,75 [1.25]

58,42 [2.3]

38,1 [1.50]

38,1 [1.5]

50,8 [2.00}

75000, 100000

228,6 [9.00]

63,5 [2.50]

63,5 [2.50]

12 196,85 [7.750]

16,76 [0.66]

2-12UN 31,75 [1.25]

58,42 [2.3]

38,1 [1.50]

38,1 [1.5]

50,8 [2.00}

150000, 200000

279,4 [11.00]

63,5 [2.50]

63,5 [2.50]

12 241,3 [9.500]

19,81 [0.78]

2 1/2-12 UN

31,75 [1.25]

58,42 [2.3]

38,1 [1.50]

38,1 [1.5]

50,8 [2.00}

300000, 400000, 500000

355,6 [14.00]

107,95 [4.25]

107,95 [4.25]

12 298,45 [11.750]

26,16 [1.03]

3 1/2-8 UN

31,75 [1.25]

58,42 [2.3]

38,1 [1.50]

38,1 [1.5]

**

*Lengthofloadcellwithamplifiedoption(seeoptioncodes)**Cdimensionvariesonhighranges.Consultfactory***Hdimensionwith2n(2N)amplifier

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008609-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 41 Precision Low Profile Load Cell

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed tootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

NOTES

1. Allowable maximum loads - maximum load to be applied without damage.2

2. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications(overheadloading,etc.)shouldalwaysbedesignedwithsafety redundant load paths.

3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal pro-vides50%(unamplifiedunits),75%(4mAto20mA3-wireunits)or80%(voltageamplifiedunits)offullscaleoutputforquickcalibration.Shuntcalibrationcomesstandardwithinternalamplifieroption2b,2c,2t and 2j.

4.O=Orange;Y=Yellow;B=Blue;Bl=Black;R=Red;Br=Brown;W=White;G=Green.Colorspecifyingcableandnumberorletterspecifying connector.

5.Nomatingconnectornecessaryforcableoption.6. Adding any internal amplifiers on 5 lb to 25 lb ranges will increase

delivery time.7.Option2n(2N)on5to5000lb.rangeswilltypicallytake12weeksfor

delivery.8.Option3disnotavailablewithoption2n(2N)or2k.9.Notavailablewithoption1c,1e,1f,1g,1hor1i.10.Consultfactory.11.Availability varies with range, consult factory.12.Optiononlypertinentwhenoption2n(2N)selected.13.Standardcalibrationfortension/compressionloadcellsisintension

only.14.Notavailablewithamplifiedoutput.15.ConsultfactoryforTEDSavailabilitywithamplifiedmodels.16.Rangedependent;consultfactory.Terminationdependent;consult

factory.17.Internalampandterminationdependent;consultfactory.18.ThisunitcalibratedtoImperial(non-Metric)units.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Precision Low Profile Load CellModel 43

DESCRIPTIONModel 43 is a low profile “pancake” type load cells. These bond-

ed foil, strain gage load cells are engineered to measure loads

from 5 lb to 500,000 lb. The compression-only Model 43 has a

load button which is fixed as an integral part of the load cell and

cannot be removed or changed. It provides high performance in

non-linearity, hysteresis, and repeatability specifications for such

applications as tube mills, extruding processes and weighing.

Each unit has a welded construction and can be hermetically

sealed for added durability. Model 43 is available with optional 0

Vdc to 5 Vdc or 4 mA to 20 mA output.

FEATURES• 0.10%accuracy

• 5lbto500000lb

• mV/Voutput(standard);0Vdcto5Vdcor4mAto20mA

(optional)

• Stainlesssteel

• Doublediaphragmdesign

Approved Approved ApprovedIntrinsically safe amp

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 43

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges9 5 lb to 500000 lb

Non-linearity, 5 lb to 25 lb ±0.2%fullscale

Hysteresis, 50 lb to 500000 lb

±0.1%fullscale

Hysteresis, 5 lb to 25 lb ±0.1%fullscale

Hysteresis, 50 lb to 500000 lb

±0.08%fullscale

Non-repeatability, 5 to 25 lb ±0.1%fullscale

Non-repeatability, 50 lb to 500000 lb

±0.03%fullscale

Output(tolerance),5 lb to 25 lb

2mV/V±0.5%fullscale

Output(tolerance),50 lb to 500000 lb

3mV/V±0.5%fullscale

Operation Compression

Resolution Infinite

Standardcalibration 5-point calibration, compression only

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto121°C[-65°Fto250°F]

Temperature, compensated 15°Cto71°C[60°Fto160°F]

Temperature effect, zero 0.002%fullscale/°F

Temperature effect, span 0.002%fullscale/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded foil

Excitation(calibration) 10Vdc

Excitation(acceptable) Upto15VdcorVac

Insulation resistance 5000 mOhm @ 50 Vdc

Bridge resistance (tolerance)

350ohm(nominal)

Zerobalance(tolerance) ±1%fullscale

Shuntcalibrationdata Included

Electricaltermination(std)5 lb to 5000 lb

PTIH-10-6P

Electricaltermination(std)7500lbto500000lb

MS3102E-14S-6P

Mating connector 5lbto5000lb(notincl.)

PT06A-10-6Sorequiv.(AA111)

Mating connector 7500to500000lb(notincl.)

MS3106A-14S-6S(AA121)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 150%FS2

Weight Seetable

Material Less than 200,000 lb

17-4PHstainlesssteel

Material greater than or equalto300000lb

Carbonsteel

Deflection Seetable

Naturalfrequency Seetable

RANGE CODES

Range Code

Available ranges Range Code

Available ranges

AT 5 lb DV 10000lb

AV 10lb EJ 15000lb

BL 25 lb EL 20000 lb

BN 50 lb EN 30000 lb

BR 100lb EP 50000 lb

CN 250 lb ER 75000lb

CR 500 lb ET 100000lb

CV 1000lb FJ 150000lb

DL 2000 lb FL 200000 lb

DN 3000 lb FN 300000 lb

DP 4000 lb FP 400000 lb

DR 5000 lb FR 500000 lb

DT 7500lb

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb) Deflection @ full scale (in)

Natural ringing frequency (Hz)

Weight kg (lb)

5 to 25 0.001 2000 0.36[0.8]

50to1000 0.002 4500 0.68[1.5]

2000 to 5000 0.002 11000 0.73[1.6]

7500to30000 0.003 9000 2.90[6.4]

50000to100000 0.004 13000 2.99[6.6]

150000to200000 0.004 11000 5.31[11.7]

300000 0.005 10000 10.8[23.8]

400000 0.007 8400 12.02[26.5]

500000 0.007 4800 41.00[90.4]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Precision Low Profile Load Cell

INTERNAL AMPLIFIERS

Amplifier specifications

Voltage out-put: Option 2a

Voltage out-put: Option 2c

Voltage out-put: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Op-tion 2n (2N)***

Output signal 0 V to 5 V 0 V to 5 V or ±5 V @ 45 mA

0Vto10Vor±10V@45mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage) ±15Vor26Vdcto 32 Vdc

11Vdcto28Vdc 15Vdcto28Vdc 22 Vdc to 32 Vdc 15Vdcto 40 Vdc

9 Vdc to 28 Vdc

Input power (current) 45 mA 40 mA 40 mA 65mA 4 mA to 28 mA 4 mA to 24 mA

Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rej. 60db 60db 60db 60db 60db 60db

Operating temp. -20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F

Reverse voltage protec-tion

Yes Yes Yes Yes Yes Yes

Short cir. protection Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)4

A(+)SupplyB Output commonCSupplyreturnD(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB No connectionCNoconnectionD(+)OutputECasegroundFNoconnection

A(+)SupplyB No connectionCNoconnectionD(+)OutputECasegroundFNoconnection

Wiring code: cable4,5,6 R(+)SupplyBl Output commonGSupplyreturnW(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl(+)OutputWCaseground

R(+)SupplyBl(+)OutputWCaseground

* Black and green wires are internally connected.**PinsBandCareinternallyconnected.***SeeourWebsiteforthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.

WIRING CODES

Connector Unamplified (Std.)

A (+)excitation

B (+)excitation

C (-)excitation

D (-)excitation

E (-)output

F (+)output

ALLOWABLE MAXIMUM LOADS2

Capacity (lb) Side load (lb)

Bending (lb-in)

Torque (lb-ft)

5 to 25 50% 40% 25%

50to1000 45% 35% 25%

2000 to 5000 30% 25% 25%

7500to30000 20% 20% 15%

50000to100000 20% 20% 15%

150000to200000 20% 20% 15%

300000 20% 20% 10%

400000 20% 20% 10%

500000 20% 20% 10%

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model 43

OPTION CODES

Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 5,10,25,50,100,250,500,1000,2000,3000,4000,5000,7500,10000,15000,20000,30000,50000,75000,100000,150000,200000,300000,400000,500000lb

Temperature compensation

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F

1g.70°Fto325°F11

1h.70°Fto400°F11

1i.-65°Fto250°F1j.0°Cto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal amplifiers

2a.Fourwire,0Vdcto5Vdcoutput2c. 0 Vdc to 5 Vdc2j.4mAto20mA(three-wire)output2k.4mAto20mA(two-wire)10

2n(2N)4mAto20mA(two-wire)intrinsicallysafe10 2t.0Vdcto10Vdcoutput2u.Unamplified,mV/Voutput

Internal amplifier enhancements

3a.Input/outputisolation7

3d. Remote buffered shunt calibration8

Electrical termination

6a.BendixPTIH-10-6P(orequivalent),6-pin(max.250°F)6b.MSconnectorMS3102E-14S-6P(mateswithMS3106E-

14S-6S)(max.160°F)(rangesabove5000lb)12

6e.Integralcable:Teflon

6f.Integralcable:PVC6g.Integralcable:Neoprene6h.Integralcable:Silicone6i.Integralunderwatercable6j.1/2-14conduitfittingwith5ftof4conductorPVCcable

Shunt calibration

8a. Precision internal resistor11

Special calibration

9a.10point(5up/5down)20%increments@70°F9b.20point(10up/10down)10%increments@70°F9c.ASTME-74calibration

Bridge resistance

12.5000ohm(foil)(max.250°F)

Bridge type 31a.Dualbridge

Zero and span adjustment

14a.Noaccesstopots14b.Topaccesstopots

Electrical connector orientation

15a.Horizontalelectricalexitportorientation15b.Verticalelectricalexitportorientation15c.Radialelectricalexitportorientation15d.Connectoronendofcable

Special calibration

30a.Compressiononly,positiveoutput

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration11

53t.TEDSIEEE1451.4module8

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl5

Precision Low Profile Load Cell

MOUNTING DIMENSIONS

Ranges lb D1 mm [in] D2 mm [in] H mm [in]

F typ. dia.

ØG mm [in] B.C.

A mm [in]

A* mm [in]

B mm [in]

B* mm [in]

C mm [in]

5,10,25 63,5[2.50] 9,4[0.37] 24,89 [0.98]

#8 50,8 [2.000]

20,83 [0.82]

63,5[2.5] 19,05[0.75]

22,86[0.9] 31,75[1.25]

50,100,250,500,1000

76,2[3.00]1 14,22[0.56] 29,97[1.18]

1/4 57,15[2.250]

20,83 [0.82]

63,5[2.5] 19,05[0.75]

22,86[0.9] 31,75[1.25]

2000, 3000, 4000, 5000

88,9[3.50] 17,53[0.69] 29,97[1.18]

5/16 66,68[2.625]

20,83 [0.82]

63,5[2.5] 19,05[0.75]

22,86[0.9] 31,75[1.25]

7500,10000,15000,20000,30000

114,3[4.50] 38,1[1.50] 50,8[2.00] 3/8 96,27[3.790]

31,75[1.25]

58,42[2.3] 38,1[1.50] 38,1[1.5] 50,8[2.00]

50000,75000,100000

114,3[4.50] 38,1[1.50] 50,8[2.00] 3/8 96,27[3.790]

31,75[1.25]

58,42[2.3] 38,1[1.50] 38,1[1.5] 50,8[2.00]

150000,200000

139,7[5.50] 50,8[2.00] 55,37[2.18]

3/8 122,22[4.812]

31,75[1.25]

58,42[2.3] 38,1[1.50] 38,1[1.5] 50,8[2.00]

300000 177,8[7.00] 63,5[2.50] 68,1[2.68] 3/8 152,4[6.00]

31,75[1.25]

58,42[2.3] 38,1[1.50] 38,1[1.5] 50,8[2.00]

400000 190,5[7.50] 63,5[2.50] 68,1[2.68] 3/8 171,45[6.750]

31,75[1.25]

58,42[2.3] 38,1[1.50] 38,1[1.5] 50,8[2.00]

500000 279,4[11.0] 120,65[4.75] 114,3[4.50]

3/4 241,3[9.500]

31,75[1.25]

58,42[2.3] 38,1[1.50] 38,1[1.5] 50,8[2.00]

*Lengthofloadcellwithamplifiedoption(seeoptioncodes)

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008627-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 43 Precision Low Profile Load Cell

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed tootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

NOTES

1. 0.12mm[3.00in]diameterhassixmountingholes.2. Allowable maximum loads - maximum load to be applied without

damage.3

3. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications(overheadloading,etc.)shouldalwaysbedesignedwith safety redundant load paths.

4. Interconnectingshuntcal.1terminalwithshuntcal.2terminalprovides50%(unamplifiedunits),75%(4mAto20mAthree-wireunits)or80%(voltageamplifiedunits)offullscaleoutputforquickcalibration.Shuntcalibrationcomesstandard

withinternalamplifieroption2a,2b,2c,2tand2j.5. O=Orange;Y=Yellow;B=Blue;Bl=Black; R=Red;Br=Brown;

W=White;G=Green.Colorspecifyingcableandnumberorletter specifying connector 6. Nomatingconnectornecessaryforcableoption.7. Onlyavailablewithoption2aor2c.8. ConsultfactoryforTEDSavailabilitywithamplifiedmodels.9. ThisunitcalibratedtoImperial(non-Metric)units.10. 5000ohmbridgerequired.11. Cannotbeusedwithamplifiedoption.12. Cannotbeusedwithoptions1c,1e,1f,1g,1h,or1i.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Precision Low Profile Load CellModel 75

DESCRIPTIONModel 75 fatigue rated load cells are engineered for applications

such as materials or product fatigue testing, which involve an

extremely large number of cycles or occasional overload condi-

tions. These fatigue rated load cells have load ranges from 50 lb

to 200,000 lbs and achieve a non-linearity of 0.1% full scale. The

superior design of these bonded foil, strain gage compression

and/or tension load cells permits a fatigue life of 1 billion cycles

(zero to full scale).

Model 75 measures tension/compression and must be used on a

smooth flat surface to achieve rated specifications. The tension/

compression Model 75 is designed with the threaded hole run-

ning completely through the center of the cell. Model 75 utilizes

two stabilizing diaphragms, which are welded to the sensing

member to reduce off-center and side-loading effects.

FEATURES• 0.10%accuracy

• 50lbto200000lb

• mV/Voutput(standard);4mAto20mAor0Vdcto5Vdc

(optional) outputs

• Stainlesssteel

• Doublediaphragmdesign

• Enhancedoverloadcapacity

• Intrinsicallysafeavailable(2Noptiononly)8

• CEapproved9

Approved Approved ApprovedIntrinsically safe amp

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 75

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges10 50 lb to 200000 lb

Non-linearity ±0.1 % full scale

Hysteresis ±0.1 % full scale

Non-repeatability ±0.03 % full scale

Output (tolerance) 2mV/V±0.5%fullscale

Operation Compression/tension

Resolution Infinite

Standardcalibration5-point calibration, 0 %, 50 %, and 100 % of full scale in tension only

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto121°C[-65°Fto250°F]

Temperature, compensated 15°Cto71°C[60°Fto160°F]

Temperature effect, zero 0.002%fullscale/°F

Temperature effect, span 0.002%fullscale/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded foil

Excitation(calibration) 10Vdc

Insulationresistance 5000mOhm@50Vdc

Bridge resistance (tolerance)

350 ohm

Zero balance (tolerance) ±1 % full scale

Shuntcalibrationdata Included

Electricaltermination(std)50 lb to 2000 lb

PTIH-10-6P

Electricaltermination(std)3000 lb to 200000 lb

MS3102E-14S-6P

Mating connector (not incl.) 50 lb to 2000 lb

PT06A-10-6Sorequiv.(AA111)

Mating connector (not incl.) 3000 to 200000 lb

MS3106A-14S-6S(AA121)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 200%FS2

Weight Seetable

Material < 100000 lb 17-4PHstainlesssteel

Material > 125000 lb Carbonsteel

Life cycles (approx.) > 108 cycles fully reversed

Deflection Seetable

Naturalfrequency Seetable

RANGE CODES

Range Code

Available ranges Range Code

Available ranges

BN 50 lb DV 10000 lb

BR 100 lb EJ 15000 lb

CN 250 lb EL 20000 lb

CR 500 lb EN 30000 lb

CV 1000 lb EP 50000 lb

DL 2000 lb ER 75000 lb

DN 3000 lb ET 100000 lb

DP 4000lb FJ 150000 lb

DR 5000 lb FL 200000 lb

DT 7500 lb

WIRING CODES

Connector Unamplified (Std.)

A (+) excitation

B (+) excitation

C (-) excitation

D (-) excitation

E (-) output

F (+) output

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb) Deflection @ full scale (in)

Natural ring-ing frequen-cy (kHz)

Weight g [lb]

50 to 500 0.001 2.5 730[1.61]

1000 to 2000 0.002 10 900[1.98]

3000 to 7500 0.002 8 4000[8.82]

10000 to 20000 0.003 10 5000[11.02]

30000 to 50000 0.003 8.2 8600[18.96]

75000 to 100000 0.004 7.5 15000[33.07]

150000 to 200000

0.006 4.5 21000[46.3]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Precision Low Profile Load Cell

INTERNAL AMPLIFIERS

Amplifier specifications

Voltage out-put: Option 2b

Voltage out-put: Option 2c

Voltage out-put: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Op-tion 2n (2N)***

Output signal ±5V 0Vto5Vor±5V@45mA

0Vto10Vor±10V@45mA

4mAto20mA 4mAto20mA 4mAto20mA

Input power (voltage) ±15Vor26Vdcto32Vdc

11Vdcto28Vdc 15Vdcto28Vdc 22Vdcto32Vdc 15Vdcto 40Vdc

9Vdcto 28Vdc

Input power (current) 45mA 40mA 40mA 65mA 4mAto28mA 4mAto24mA

Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rej. 60db 60db 60db 60db 60db 60db

Operating temp. -20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F

Reverse voltage protec-tion

Yes Yes Yes Yes Yes Yes

Short cir. protection Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)4

A(+)SupplyB Output commonCSupplyreturnD(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

Wiring code: cable4,5,6 R(+)SupplyBl Output commonGSupplyreturnW (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl (+) OutputWCaseground

R(+)SupplyBl (+) OutputWCaseground

* Black and green wires are internally connected.**PinsBandCareinternallyconnected.***SeeourWebsiteforthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.

ALLOWABLE MAXIMUM LOADS2

Capacity (lb) Side load (lb)

Bending (lb-in)

Torque (lb-ft)

50 to 500 75 % 60% 35 %

1000 to 2000 45% 35 % 35 %

3000 to 7500 30 % 30 % 25 %

10000 to 20000 30 % 30 % 25 %

30000 to 50000 30 % 30 % 15 %

75000 to 100000 30 % 30 % 15 %

150000 to 200000

30 % 30 % 15 %

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model 75

OPTION CODES

Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 50,100,250,500,1000,2000,3000,4000,5000,7500,10000,15000,20000,30000,50000,75000,150000,200000lb

Temperature compensation

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F

1g.70°Fto325°F13

1h.70°Fto400°F13

1i.-65°Fto250°F13

1j.0°Cto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal amplifiers

2b.Fourwire,±5Vdcoutput2c.0Vdcto5Vdc2j.4mAto20mA(three-wire)output2k.4mAto20mA(two-wire)12

2n(2N)4mAto20mA(two-wire)intrinsicallysafe12 2t.0Vdcto10Vdcoutput2u.Unamplified,mV/Voutput

Internal amplifier enhancements

3a.Input/outputisolation11

3d. Remote buffered shunt calibration8

Electrical termination

6a.BendixPTIH-10-6P(rangesto2000lb)6b.MSconnectorMS3102E-14S-6P(mates

withMS3106E-14S-6S)(max.160°F)(ranges 2000 lb and above)14

6e.Integralcable:Teflon6f.Integralcable:PVC

6g.Integralcable:Neoprene6h.Integralcable:Silicone6i.Integralunderwatercable6j.1/2-14conduitfittingwith5ftof4conductorPVCcable

Shunt calibration 8a. Precision internal resistor13

Bridge resistance 12b.5000ohm(foil)(max.250°F)

Bridge type 31a.Dualbridge

Zero and span adjustment

14a.Noaccesstopots14b.Topaccesstopots

Electrical connector orientation

15a. Horizontal electrical exit port orientation15b.Verticalelectricalexitportorientation15c. Radial electrical exit port orientation15d.Connectoronendofcable

Special calibration

30a.Compressiononlycalibration,positiveincompression30b. Tension and compression calibration, positive in tension

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration13

53t.TEDSIEEE1451.4module7

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl5

Precision Low Profile Load Cell

MOUNTING DIMENSIONS

Ranges lb

D mm [in]

H mm [in]

F # ØG mm [in] B.C.

ØK mm [in] thru

T A mm [in]

A* mm [in]

B mm [in]

B* mm [in]

C mm [in]

50 to 500

76,2[3.00]

25,4[1.00]

6 57,15 [2.250]

7,11 [0.28]

3/8-24UNF

20,83 [0.82]

63,5[2.5] 19,05 [0.75]

22,86[0.9]

31,75 [1.25]

1000 to 2000

88,9 [3.50]

25,4[1.00]

6 66,68[2.625]

8.64[0.34]

1/2-20 UNF

20,83 [0.82]

63,5[2.5] 19,05 [0.75]

22,86[0.9]

31,75 [1.25]

3000 to 7500

139,7 [5.50]

45,72[1.80]

8 114,3[4.500]

10,16[0.40]

1-14UNS 31,75 [1.25]

58,42[2.3]

38,1 [1.50]

38,1[1.5] 50,8 [2.00]

10000 to 20000

152,4[6.00]

45,72[1.80]

8 123,83 [4.875]

13,46[0.53]

1 1/2-12 UN

31,75 [1.25]

58,42[2.3]

38,1 [1.50]

38,1[1.5] 50,8 [2.00]

30000 to 50000

190,5 [7.50]

50,8 [2.00]

8 152,4[6.00]

19,81 [0.78]

2-12UN 31,75 [1.25]

58,42[2.3]

38,1 [1.50]

38,1[1.5] 50,8 [2.00]

75000 to 100000

228,6[9.0]

63,5[2.50]

12 196,85[7.75]

16,76[0.66]

2 1/2-12 UN

31,75 [1.25]

58,42[2.3]

38,1 [1.50]

38,1[1.5] 50,8 [2.00]

150000, 200000

355,6[14.00]

107,95 [4.25]

12 298,45[11.750]

26,16[1.03]

3 1/2-8 UN

31,75 [1.25]

58,42[2.3]

38,1 [1.50]

38,1 [1.50]

**

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008611-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 75 Precision Low Profile Load Cell

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed tootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

NOTES

1. Cdimensionvariesonhighranges.Consultfactory.2. Allowablemaximumloads-maximumloadtobeappliedwithout

damage.3 3. Without damage - loading to this level will not cause excessive zero

shift or performance degradation. The user must consider fatigue life forlongtermuseandstructuralintegrity.Allstructurallycriticalap-plications (overhead loading, etc.) should always be designed with safety redundant load paths.

4. Interconnectingshuntcal.1terminalwithshuntcal.2terminalprovides50%(unamplifiedunits),75%(4mAto20mAthree-wireunits)or80%(voltageamplifiedunits)offullscaleoutputforquickcalibration.Shuntcalibrationcomesstandardwithinternalamplifieroption 2a, 2b, 2c, 2t and 2j.

5. O=Orange;Y=Yellow;B=Blue;Bl=Black; R=Red;Br=Brown;W=White;G=Green.Colorspecifyingcableandnumberorletter

specifying connector. 6. Nomatingconnectornecessaryforcableoption.7.ConsultfactoryforTEDSavailabilitywithamplifiedmodels.8. Rangedependent;consultfactory.Terminationdependent;consult

factory.9. Internalampandterminationdependent;consultfactory.10.ThisunitcalibratedtoImperial(non-Metric)units.11.Input/outputisolationonlyavailablewithvoltageoutput(2bor2c)

amplifiers.12.5000ohmbridgerequired.13.Cannotbeusedwithamplifiedoption.14.Cannotbeusedwithoptions1c,1e,1f,1g,1h,or1i.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Ultra Precision Universal Canister Load CellModel UG

DESCRIPTIONModel UG Ultra Precision Universal load cell achieves scale

quality and performance standards.The Model UG achieves

±0.03 % non-linearity with very little deflection (typically .0045

in). It utilizes a four arm strain gage bridge which is bonded

and tested for high precision and dependability. Female threads

on both ends facilitate mounting in any position for tension,

compression, or universal force measurements. Model UG load

cells can be used in both static and dynamic applications.

Stainless steel construction ensures high reliability.

FEATURES• 5lbto50000lb

• 0.03%non-linearityandhysteresis,respectively

• Stainlesssteel

• Minifootprint

• Button-styledesign

• mV/Voutput

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model UG

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges12 100 lb to 150000 lb

Non-linearity ±0.03 % full scale1

Hysteresis ±0.03 % full scale1

Non-repeatability ±0.02 % full scale

Output (tolerance) 3mV/V±1%

Load direction Tension/compression4

Resolution Infinite

Creep(max.) 0.02 % (20 min.)

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bondedfoil

Excitation(calibration) 10Vdc

Insulation resistance 5000mOhm@50Vdc

Bridgeresistance 350 ohm

Zero balance 1 % of full scale

Electrical termination (std) MS3102E-14S-6P

Mating connector (not included)

MS3106A-14S-6S (AA121)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximumallowableload 150 % FS 2

Material Stainless steel

WIRING CODES

Connector Unamplified

A (+)excitation

B (+)excitation

C (-)excitation

D (-)excitation

E (-) output

F (+) output

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -34°Cto85°C[-30°Fto185°F]5

Temperature, compensated 15°Cto71°C[60°Fto160°F]5

Temperature, storage -73°Cto121°C[-100°Fto250°F]

Temperature effect, zero 0.0015%fullscale/°F

Temperature effect, span 0.0008%fullscale/°F

MOUNTING DIMENSIONS

Rang-es lb

H mm [in]

ØD1 mm [in]

ØD2 mm [in]

ØD3 mm [in]

A mm [in]

T

100 69,85[2.75]

50,8[2.00]

16,00 [0.63]

48,26[1.9]

2,29 [0.09]

3/8-24UNFx7/16in

250, 500

69,85[2.75]

50,8[2.00]

16,00 [0.63]

48,26[1.9]

4,57[0.18]

3/8-24UNFx7/16in

1000, 2000, 3000, 4000

104,90 [4.13]

63,5 [2.50]

19,05 [0.75]

50,8[2.00]

4,57[0.18]

1/2-20UNFx5/8in

5000, 7500,10000

149,35 [5.88]

88,9[3.50]

39,62 [1.56]

76,2[3.00]

4,83[0.19]

1-14UNFx11/8in

15000, 20000, 30000

215,9 [8.50]

127[5.00]

60,45 [2.38]

109,22 [4.3]

16,00 [0.63]

11/2-12UNFx2in

50000, 75000

304,8[12.00]

152,4 [6.00]

92,20 [3.63]

139,7[5.5]

17,53[0.69]

2-12UNFx21/2in

100000, 150000

401,32 [15.80]

190,5 [7.5]

121,92 [4.8]

172,72[6.8]

17,53[0.69]

3-8UNFx41/2in

RANGE CODES

Range Code

Available ranges Range Code

Available ranges

BR 100 lb DV 10000 lb

CN 250 lb EJ 15000 lb

CR 500 lb EL 20000 lb

CV 1000 lb EN 30000 lb

DL 2000 lb EP 50000 lb

DN 3000 lb ER 75000lb

DP 4000 lb ET 100000 lb

DR 5000 lb FJ 150000 lb

DT 7500lb

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Ultra Precision Universal Canister Load Cell

INTERNAL AMPLIFIERS

Amplifier specifications

Voltage output: Option 2b

Voltage output: Option 2c

Voltage output: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Op-tion 2n (2N)***

Output signal ±5V 0Vto5Vor±5V@ 45 mA

0Vto10Vor±10V@45mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage)

±15Vor26Vdcto32Vdc

11Vdcto28Vdc 15Vdcto28Vdc 22Vdcto32Vdc 15Vdcto 40Vdc

9Vdcto 28Vdc

Input power (current)

45 mA 40 mA 40 mA 65 mA 4mAto28mA 4 mA to 24 mA

Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rej.

60 db 60 db 60 db 60 db 60 db 60 db

Operating temp. -20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F

Reverse voltage protection

Yes Yes Yes Yes Yes Yes

Short cir. pro-tection

Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)

A (+) SupplyBOutputcommonCSupplyreturnD (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyBOutputcommon**CSupplyreturn**D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyBOutputcommon**CSupplyreturn**D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyBOutputcommon**CSupplyreturn**D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyBNoconnectionCNoconnectionD (+) OutputECasegroundF No connection

A (+) SupplyBNoconnectionCNoconnectionD (+) OutputECasegroundF No connection

Wiring code: cable5,6,7

R (+) SupplyBlOutputcommonG Supply returnW (+) OutputBShuntcal1BrShuntcal2

R (+) SupplyBlOutputcommon*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R (+) SupplyBlOutputcommon*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R (+) SupplyBlOutputcommon*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R (+) SupplyBl(+)OutputWCaseground

R (+) SupplyBl(+)OutputWCaseground

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model UG

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges

100,250,500,1000,2000,3000,4000,5000,7500,10000,15000,20000,30000,50000,75000,100000,150000 lb

Tempera-ture com-pensation

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c.0°Fto185°F1d. -20 °F to 200 °F1e. -20 °F to 200 °F1f.70°Fto250°F

1g.70°Fto325°F14

1h.70°Fto400°F14

1i. -65 °F to 250 °F14

1j.0°Cto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal amplifiers

2b.±5Vdc2c.0Vdcto5Vdcoutput 2j. 4 mA to 20 mA (three-wire) out2k. 4 mA to 20 mA (two-

wire)13

2n (2N) 4 mA to 20 mA (wire) intrinsically safe13

2t.0Vdcto10Vdc2u.Unamplified,mV/Voutput

Electrical termination

6a.BendixPTIH-10-6P(or equivalent) 6-pin (max.250°F)

6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6S) (max160°F)16

6e. Integral cable: Teflon

6g. Integral cable: Neo-prene

6i. Submersible cable15

6j.1/2-14conduitfittingwith 5 ft of 4 conductor PVCcable

6q. Integral cable: Poly-urethane

Shunt cali-bration

8a.Precisioninternalresistor14

Bridge resistance

12b. 5000 ohm (foil)11a. Square bridge14

11b. Symmetrical bridge14

11c. Square and symmetrical bridge14

Special calibration

30a. Compressiononlycalibration,positiveincom-pression

30b. Tension and compression calibration, positive in tension

30c. Compressiononlycalibration,negativeincom-pression

Shock and vibration

44a. Shock and vibration resistance

Interfaces 53e. Signature calibration14

53t. TEDS IEEE 1451.4 module9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008643-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model UG Ultra Precision Universal Canister Load Cell

NOTES

1. ±0.05% full scale less than or equal to 250 lb and greater than or equalto75000lb.

2. Allowablemaximumloads-maximumloadtobeappliedwithoutdamage.3

3. Withoutdamage–loadingtothislevelwillnotcauseexcessivezero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structur-ally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

4. Standardcalibrationfortension/compressionloadcellsisinten-sion only.

5. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides50%(unamplifiedunits),75%(4mAto20mAthree-wireunits)or80%(voltageamplifiedunits)offullscaleoutputforquickcalibration. Shunt calibration comes standard with internal amplifier option 2b, 2c, 2t and 2j.

6. O=Orange;Y=Yellow;B=Blue;Bl=Black;R=Red;Br=Brown;W=White;G=Green.Colorspecifyingcableandnumberorletterspecifying connector.

7. Nomatingconnectornecessaryforcableoption.8. Consultfactoryforextendedtemperatureranges.9.ConsultfactoryforTEDSavailabilitywithamplifiedmodels.10. Range dependent; consult factory. Termination dependent; consult

factory.11. Internal amp and termination dependent; consult factory.12. This unit calibrated to Imperial (non-Metric) units.13. 5000 ohm bridge required14. Not available with amplified options.15. Temperature82°C[180°F]max.,non-shieldedstandard,shielded

available.16. Cannotbeusedwithoptions1c,1e,1f,1g,1h,or1i.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

High Output Load CellModel AL-JP

DESCRIPTIONModel AL-JP is a high output load cell (30 mV/V minimum).

These semiconductor strain gage load cells are engineered to

measure loads from 500 lb to 2000 lb. The tension/compression

Model AL-JP is designed with female threads. It provides high

performance in non-linearity, hysteresis, and repeatability. Low

mechanical deflection allows for better response capability.

FEATURES• 500lb,1000lb,and2000lbrange

• Tension/compression

• Highoutput/lowbridgeresistance(125Ohmnominal)

• Drivemeterswithoutamplification

• Lowmechanicaldeflection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model AL-JP

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges4 500,1000,2000lb

Accuracy (static error band)1

±0.15%fullscale

Non-repeatability ±0.05%fullscale

Output 30 mV/V minimum

Operation Tension/compression

Resolution Infinite

RANGE CODES

Range Codes Range

CR 500 lb

CV 1000lb

DL 2000 lb

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded semiconductor

Excitation (calibration) 5VdcorVac(RMS)

Insulation resistance 5000mOhm@50VdcorV

Bridge resistance 125ohmnominal(inputandoutput)

Zero balance 3.0%fullscale(max.)

Electrical termination (std) 3106B-14S-5Pconnectormountedatendof10ftcable

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 150%fullscale2

Sideloadwithoutdamage 100%

Weight Seetable

Material 17-4PHstainlesssteel

Deflection Seetable

Natural frequency Seetable

WIRING CODES

Tension

A (+) excitation

B (+) signal

C (-) signal

D (-) excitation

E shield

Compression

A (+) excitation

B (-) signal

C (+) signal

D (-) excitation

E shield

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated -1°Cto54°C[30°Fto130°F]

Temperature, storage -73°Cto121°C[-100°Fto250°F]

Temperature effect, zero 0.5%fullscale/°F

Temperature effect, span 0.5%reading/°F

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load range 500lb,1000lb,2000lb

Temperaturecompensation

10°Fto120°F

Internal amplifiers

2u.Unamplified,mV/Voutput

Electrical termination

3106B-14S-5Pconnectormountedatendof10ftcable

Special calibration

30a.Compressiononly(+)output30b. Tension and compression (+,-) output30c.Compressiononly(-)output

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

High Output Load Cell

MOUNTING DIMENSIONS DEFLECTIONS AND RINGING FREQUENCIES

Capacity Axial deflec-tion at full scale mm [in]

Natural fre-quency (Hz)

Weight kg [lb]

500 lb 0,025 mm [0.0010]

5000 0,544[1.2]

1000lb 0,038 mm [0.0015]

6000 0,544[1.2]

2000 lb 0,051mm[0.0020]

6700 0,544[1.2]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

008673-2-EN IL50 GLO March 2009Copyright © 2009 Honeywell International Inc. All rights reserved.

Model AL-JP High Output Load Cell

Find out more

Honeywellservesitscustomers

through a worldwide network of

salesoffices,representativesand

distributors.Forapplicationas-

sistance,currentspecifications,

pricing or name of the nearest

AuthorizedDistributor,contact

yourlocalsalesoffice.

TolearnmoreaboutHoneywell’s

test and measurement products,

call +1-614-850-5000, visit

www.honeywell.com/sensotec,

or e-mail inquiries to

[email protected]

Sensing and Control

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422

www.honeywell.com

NOTES

1. Staticerrorbandistherecommendedperformancespecifica-tion.Thestaticerrorbandiscalculatedasthebestfitstraightlinethrough zero, including the effects of non-linearity, hysteresis and non-repeatability.

2. Allowable maximum loads – maximum load to be applied without damage3.

3. Without damage - loading to this level will not cause excessive zero shift of performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

4. This unit calibrated to Imperial (non-Metric) units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

High Output Load CellModel AL-SC

DESCRIPTIONModel AL-SC is high-output load cell. These semiconductor

strain gage load cells are engineered to measure loads from 500

lb to 2000 lb. The tension/compression Model AL-SC is de-

signed with female threads. It provides high performance in non-

linearity, hysteresis, and repeatability. Low mechanical deflection

allows for better response capability.

FEATURES• 500lb,1000lb,and2000lbrange

• 0.15%accuracy

• Tension/compression

• Highoutput/lowbridgeresistance

• Lowmechanicaldeflection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model AL-SC

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges4 500,1000,2000lb

Accuracy (static error band)1

±1.25%fullscale

Non-repeatability ±0.10%fullscale

Output 70 mV/V minimum

Operation Tension/compression

Resolution Infinite

RANGE CODES

Range Codes Range

CR 500 lb

CV 1000lb

DL 2000 lb

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bonded semiconductor

Excitation (calibration) 24 Vdc or Vac (RMS)

Insulation resistance 5000 mOhm @ 50 Vdc

Bridge resistance, input 1000ohm(nominal)

Bridge resistance, output 3000 ohm (nominal)

Zero balance 1.5%fullscale(max.)

Electrical termination (std) MS3100A-14S-5Patendof1ftcable

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 200%fullscale2

Side load without damage 25%fullscale

Weight See table

Material 17-4PHstainlesssteel

Deflection See table

Natural frequency See table

WIRING CODES

Tension

A (+) excitation

B (+) signal

C (-) signal

D (-) excitation

E shield

Compression

A (+) excitation

B (-) signal

C (+) signal

D (-) excitation

E shield

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]

Temperature, compensated -12°Cto49°C[10°Fto120°F]

Temperature, storage -73°Cto121°C[-100°Fto250°F]

Temperature effect, zero 0.5%fullscale/°F

Temperature effect, span 1.0%reading/°F

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load range 500lb,1000lb,2000lb

Temperaturecompensation

10°Fto120°F

Internal amplifiers

2u. Unamplified, mV/V output

Electrical termination

3106B-14S-5Pconnectormountedatendof10ftcable

Special calibration

30a. Compression only (+) output30b. Tension and compression (+,-) output30c. Compression only (-) output

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

High Output Load Cell

MOUNTING DIMENSIONS DEFLECTIONS AND RINGING FREQUENCIES

Capacity Axial deflec-tion at full scale mm [in]

Natural fre-quency (Hz)

Weight kg [lb]

500 lb 0,025 mm [0.0010]

5000 0,544[1.2]

1000lb 0,038 mm [0.0015]

6000 0,544[1.2]

2000 lb 0,051mm[0.0020]

6700 0,544[1.2]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Sensing and Control

Automation and Control Solutions

Honeywell

1985DouglasDriveNorth

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008672-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model AL-SC High Output Load Cell

NOTES

1. Staticerrorbandistherecommendedperformancespecifica-tion. The static error band is calculated as the best fit straight line through zero, including the effects of linearity, hysteresis and non-repeatability.

2. Allowable maximum loads – maximum load to be applied without damage3.

3. Without damage - loading to this level will not cause excessive zero shift of performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

4. This unit calibrated to Imperial (non-Metric) units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.

For more information about Sensing and Control products, visit www.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Low Range Precision Miniature Load CellModel 31 Low

DESCRIPTIONModel 31 low range precision miniature load cells measure

both tension and compression load forces of 50 grams to 500

g. These models are our highest accuracy, rugged miniature

load cells. Model 31’s welded, stainless steel construction is

designed to eliminate or reduce to a minimum, the effects of

off-axis loads. (The internal construction assures excellent long-

term stability for ranges 1000 grams and above.) A modification

permits this model to be completely welded for underwater

applications. The Model 31 tension/compression load cell has

male threads attachments. High accuracies of 0.15 % to 0.25 %

full scale are achieved. Each bonded strain gage unit is built of

welded 17-4 PH stainless steel for additional ruggedness.

FEATURES• 50gto500g

• mV/Voutput

• Stainlesssteel

• Miniaturedesign

• Doublediaphragmconstruction

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 31 Low

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges5 50 g, 150 g, 250 g, 500 g

Linearity ±0.15 % full scale

Hysteresis ±0.15 % full scale

Non-repeatability ±0.1 % full scale

Tolerance on output 50 g to 150 g

0,1mV/Vmax.

Tolerance on output 250 g to 500 g

20mV/V

Operation Tension/compression 3

Resolution Infinite

RANGE CODES

Range Codes Range

AJ 50 g

AL 150 g

AN 250 g

AP 500 g

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Semiconductor

Excitation (calibration) 5Vdc

Insulation resistance 5000Mohm@50Vdc

Bridge resistance 500 ohm

Zero balance 1 % max.

Electrical termination (std) Teflon cable (5 ft)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 5 lb1

Weight 90 g

Material 17-4 PH stainless steel

Deflectionfullscale 0,020 mm [0.0008 in]

Natural frequency 740 Hz

WIRING CODES

Cable

Red (+) excitation

Black (-) excitation

Green (-) output

White (+) output

MOUNTING DIMENSIONS

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -53°Cto121°C[-65°Fto250°F]

Temperature, compensated 15°Cto71°C[60°Fto160°F]

Storagetemperature -73°Cto148°C[-100°Fto300°F]

Temperature effect, zero 0.015%fullscale/°F

Temperature effect, span 0.015%fullscale/°F

6-32 UNC base thread

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load range 50, 150, 250, 500 g

Temperature compensa-tion

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F

1e.-20°Fto200°F1j.0°Fto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal am-plifiers

2u.Unamplified,mV/Voutput

Overload stops

4a. Overload stop

Electrical termination

6d.MicrotecDR-4S-4H4-pin

6e.Integralcable:Teflon6f.Integralcable:PVC6h.Integralcable:Sili-

cone

6i.Integralunderwatercable(max.82°C[180°F])

6v.Phoenixconnectoron end of cable

15d.Connectoronendof cable

Special cali-bration

30a.Compressiononlycalibration,positiveincom-pression

30b. Tension and compression calibration, positive in tension

30c.Compressiononlycalibration,negativeincom-pression

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 4 53e.Signaturecalibration6

53t.TEDSIEEE1451.4module

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008629-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 31 Low Low Range Precision Miniature Load Cell

TYPICAL SYSTEM DIAGRAM

NOTES

1. Allowable maximum loads - maximum load to be applied without damage. 2

2. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life or long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

3. Standardcalibrationfortension/compressionloadcellsisintensiononly.

4. TEDSavailablewithintegralcableunitsonly.5. This unit calibrated to Imperial (non-Metric) units.6. Signaturecalibrationonlyavailableasinlinemodule.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Mid Range Precision Miniature Load CellModel 31 Mid

FEATURES• 1000gto1000lb

• mV/Voutput

• Stainlesssteel

• Miniaturedesign

DESCRIPTIONModel31midrangeprecisionminiatureloadcellsmeasureboth

tensionandcompressionloadforcesof1000gto1000lb.These

modelsareourhighestaccuracy,ruggedminiatureloadcells.

Model31’swelded,stainlesssteelconstructionisdesignedto

eliminateorreducetoaminimum,theeffectsofoff-axisloads.

(Theinternalconstructionassuresexcellentlong-termstability

forranges1000gramsandabove.)Amodificationpermitsthis

modeltobecompletelyweldedforunderwaterapplications.

TheModel31tension/compressionloadcellhasmalethreads

attachments.Highaccuraciesof0.15%to0.25%fullscaleare

achieved.Eachbondedstraingageunitisbuiltofwelded17-4

PHstainlesssteelforadditionalruggedness.Allloadcellswith

rangesfrom1kgto10lbhaveanelectricalbalancemodulein

theleadwire(approximately1inx.087inthick).Thisbalance

moduledoesnothavetobethesametemperatureasthe

transducer.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 31 Mid

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadranges6 1000g,5lb,10lb,25lb,50lb,100lb,250lb,500lb,1000lb

Linearity1000gto250lb ±0.15%fullscale

Linearity500lbto1000lb ±0.2%fullscale

Hysteresis1000gto250lb ±0.15%fullscale

Hysteresis500lbto1000lb ±0.2%fullscale

Non-repeatability1000g ±0.1%fullscale

Non-repeatability5lbto1000lb

±0.05%fullscale

Toleranceonoutput1000g 1.5mV/V(nominal)

Toleranceonoutput5lbto1000lb

2mV/V

Operation Tension/compression3

Resolution Infinite

RANGE CODES

Range codes Range

AR 1000g

AT 5lb

AV 10lb

BL 25lb

BN 50lb

BR 100lb

CN 250lb

CR 500lb

CV 1000lb

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bondedfoil

Excitation(calibration)1kgto10lb

5Vdc

Excitation(calibration)25lbto1000lb

10Vdc

Insulationresistance 5000Mohm@50Vdc

Bridgeresistance 350ohm

Zerobalance 1%max.

Electricaltermination(std) Tefloncable(1524mm[60in])

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximumallowableload 150%FS1

Weight Seetable

Material 17-4PHstainlesssteel

Deflectionfullscale Seetable

Naturalfrequency Seetable

WIRING CODES

Cable Unamplified

Red (+)excitation

Black (-)excitation

Green (-)output

White (+)output

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature,operating -53°Cto121°C[-65°Fto250°F]

Temperature,compensated 15°Cto71°C[60°Fto160°F]

Storagetemperature -73°Cto148°C[-100°Fto300°F]

Temperatureeffect,zero 0.005%fullscale/°F

Temperatureeffect,span 0.005%fullscale/°F

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb)

Deflection at full scale (in)

Ringing fre-quency (Hz)

Weight (g)

1000gto10lb

0,03mm[0.001in] 3000Hz 21g

25lbto100lb

0,03mm[0.001in] 10000Hz 63g

250lbto1000lb

0,04mm[0.0015in] 12000Hz 80g

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Mid Range Precision Miniature Load Cell

MOUNTING DIMENSIONS

Ranges (lb) T H C F A B

1000g,5lb,10lb #6-32UNC 11,43mm[0.45in]

6,35mm[0.25in]

1,27mm[0.05in]

7,87mm[0.31in]

4,83mm[0.19in]

25lb,50lb,100lb #10-32UNF 13,21mm[0.52in]

6,35mm[0.25in]

0,76mm[0.03in]

12,7mm[0.50in]

6,35mm[0.25in]

250lb,500lb,1000lb 1/4-28UNF 13,21mm[0.52in]

9,65mm[0.38in]

0,76mm[0.03in]

12,7mm[0.50in]

6,35mm[0.25in]

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load range 1000g,5lb,10lb,25lb,50lb,100lb,250lb,500lb,1000lb

Temperaturecompensation

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F

1g.70°Fto325°F1h.70°Fto400°F1i.-65°Fto250°F1j.0°Cto50°C1k.-20°Cto85°C1m.-25°to110°C

Internal amplifiers

2u.Unamplified,mV/Voutput

Overload stops

4a.Overloadstops

Electrical termination

6a.BendixPTIH-10-6P-6pin(max.250°F)5

6d.MicrotecDR-4S-4H4pin

6e.Integralcable:Teflon

6f. Integralcable:PVC

6h.Integralcable:Sili-cone

6i. Integralunderwatercable(max.180°F)

6v.Phoenixconnectoronendofcable

15d.Connectoronendofcable

Special calibration

9a.10point(5up/5down)20%increments@20°C

9b.20point(10up/10down)10%increments@20°C

Special calibration

30a. Compressiononlycalibration,positiveincompression

30b. Tensionandcompressioncalibration,posi-tiveintension

30c. Compressiononlycalibration,negativeincompression

Shock and vibration

44a.Shockandvibrationresistance

Interfaces4 53e.Signaturecalibration7

53t.TEDSIEEE1451.4module

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008630-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 31 Mid Mid Range Precision Miniature Load Cell

TYPICAL SYSTEM DIAGRAM

NOTES

1. Allowablemaximumloads-maximumloadtobeappliedwithout damage.22. Withoutdamage-loadingtothislevelwillnotcauseexcessivezero

shiftorperformancedegradation.Theusermustconsiderfatiguelifeforlongtermuseandstructuralintegrity.Allstructurallycriticalapplications(overheadloading,etc.)shouldalwaysbedesignedwithsafetyredundantloadpaths.

3. Standardcalibrationfortension/compressionloadcellsisintensiononly.

4. TEDSavailablewithintegralcableunitsonly.5. Availabilityvarieswithrange.6. ThisunitcalibratedtoImperial(non-Metric)units.7. Signaturecalibrationonlyavailableasinlinemodule.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

High Range Precision Miniature Load CellModel 31 High

FEATURES• 2000lbto10000lb

• mV/Voutput

• Stainlesssteel

• Miniaturedesign

• Stabilizedcolumnconstruction

DESCRIPTIONModel31highrangeprecisionminiatureloadcellsmeasure

bothtensionandcompressionloadforcesof2000lbto10000

lb.Thesemodelsareourhighestaccuracy,ruggedminiature

loadcells.Model31’swelded,stainlesssteelconstructionis

designedtoeliminateorreducetoaminimum,theeffectsof

off-axisloads.(Theinternalconstructionassuresexcellentlong-

termstabilityforranges1000gramsandabove.)Amodification

permitsthismodeltobecompletelyweldedforunderwater

applications.TheModel31tension/compressionloadcellhas

malethreadsattachments.Highaccuraciesof0.15%to0.25%

fullscaleareachieved.Eachbondedstraingageunitisbuiltof

welded17-4PHstainlesssteelforadditionalruggedness.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 31 High

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadranges5 2000lbto10000lb

Linearity ±0.2%fullscale

Hysteresis ±0.2%fullscale

Non-repeatability ±0.05%fullscale

Toleranceonoutput 2mV/V

Operation Tension/compression3

Resolution Infinite

RANGE CODES

Range codes Range

DL 2000lb

DN 3000lb

DP 4000lb

DR 5000lb

DT 7500lb

DV 10000lb

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bondedfoil

Excitation(calibration) 5Vdc

Insulationresistance 5000Mohm@50Vdc

Bridgeresistance 350ohm

Zerobalance 1%max.

Electricaltermination(std) Tefloncable(1524mm[60in])

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximumallowableload 150%FS1

Weight Seetable

Material 17-4PHstainlesssteel

Deflectionfullscale Seetable

Naturalfrequency Seetable

WIRING CODES

Cable Unamplified

Red (+)excitation

Black (-)excitation

Green (-)output

White (+)output

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature,operating -53°Cto121°C[-65°Fto250°F]

Temperature,compensated 15°Cto71°C[60°Fto160°F]

Storagetemperature -73°Cto148°C[-100°Fto300°F]

Temperatureeffect,zero 0.005%fullscale/°F

Temperatureeffect,span 0.005%fullscale/°F

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb)

Deflection at full scale

Ringing frequency

Weight

2000lb,3000lb

0.03mm[0.001in] 26000Hz 60g

4000lb,5000lb

0.04mm[0.0015in] 21000Hz 125g

7500lb,10000lb

0.04mm[0.0015in] 17000Hz 250g

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

High Range Precision Miniature Load Cell

MOUNTING DIMENSIONS

Ranges (lb) T ØD C H

2000lb,3000lb 3/8-24UNF 25,4mm[1.00in] 12,7mm[0.50in] 18,29mm[0.72in]

4000lb,5000lb 1/2-20UNF 31,75mm[1.25in] 16mm[0.63in] 23,88mm[0.94in]

7500lb,10000lb 3/4-16UNF 35,05mm[1.38in] 22,35mm[0.88in] 27,94mm[1.10in]

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load range 2000lb,3000lb,4000lb,5000lb,7500lb,10000lb

Temperaturecompensation

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F

1g.70°Fto325°F1h.70°Fto400°F1i.-65°Fto250°F1j.0°Cto50°C1k.-20°Cto85°C1m.-25°to110°C

Internal amplifiers

2u.Unamplified,mV/Voutput

Electrical termination

6e.Integralcable:Teflon

6d.MicrotecDR-4S-4H4pin

6f. Integralcable:PVC6g.Integralcable:

Neoprene(max.180°F)

6h.Integralcable:Sili-cone

6i. Integralunderwatercable(max.180°F)

6v.Phoenixconnectoronendofcable

Bridge resistance

12a.1000ohm(foil)12b.5000ohm(foil)

Electrical connector orientation

15a.Horizontalelectricalexitportorientation15b.Verticalelectricalexitportorientation15c.Radialelectricalexitportorientation15d.Connectoronendofcable

Special calibration

30a. Compressiononlycalibration,positiveincompression

30b. Tensionandcompressioncalibration,posi-tiveintension

30c. Compressiononlycalibration,negativeincompression

30d. Tensionandcompressioncalibration,posi-tiveincompression

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration6

53t.TEDSIEEE1451.4module4

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008631-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 31 High High Range Precision Miniature Load Cell

TYPICAL SYSTEM DIAGRAM

NOTES

1. Allowablemaximumloads-maximumloadtobeappliedwithout damage.22. Withoutdamage-loadingtothislevelwillnotcauseexcessivezero

shiftorperformancedegradation.Theusermustconsiderfatiguelifeforlongtermuseandstructuralintegrity.Allstructurallycriticalapplications(overheadloading,etc.)shouldalwaysbedesignedwithsafetyredundantloadpaths.

3. Standardcalibrationfortension/compressionloadcellsisintensiononly.

4. TEDSavailablewithintegralcableunitsonly.5. ThisunitcalibratedtoImperial(non-Metric)units.6. Signaturecalibrationonlyavailableasinlinemodule.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Precision Miniature Load CellModel 34

FEATURES• 1000gto1000lb

• Weldedstainlesssteel

• Rugged,smallsize

• Tension/compression

• 0.15%/0.20%accuracy

DESCRIPTIONModel34precisionminiatureloadcellsmeasurebothtension

andcompressionloadforcesof1000gto1000lb.These

modelsareourhighestaccuracy,ruggedminiatureloadcells.

Model34’swelded,stainlesssteelconstructionisdesignedto

eliminateorreducetoaminimum,theeffectsofoff-axisloads.

(Theinternalconstructionassuresexcellentlong-termstability

forranges1000gramsandabove.)Amodificationpermitsthis

modeltobecompletelyweldedforunderwaterapplications.

TheModel34tension/compressionloadcellhasfemalethreads

attachments.Highaccuraciesof0.15%to0.25%fullscaleare

achieved.Eachbondedstraingageunitisbuiltofwelded17-4

PHstainlesssteelforadditionalruggedness.Allloadcellswith

rangesfrom1kgto10lbhaveanelectricalbalancemodulein

theleadwire(approximately1inx.087inthick).Thisbalance

moduledoesnothavetobethesametemperatureasthe

transducer.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 34

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadranges6 1000g,5lb,10lb,25lb,50lb,100lb,250lb,500lb,1000lb

Linearity1000gto250lb ±0.15%fullscale

Linearity500lbto1000lb ±0.2%fullscale

Hysteresis1000gto250lb ±0.15%fullscale

Hysteresis500lbto1000lb ±0.2%fullscale

Non-repeatability1000g ±0.1%fullscale

Non-repeatability5lbto1000lb

±0.05%fullscale

Toleranceonoutput1000g 1.5mV/V(nominal)

Toleranceonoutput5lbto1000lb

2mV/V

Operation Tension/compression3

Resolution Infinite

RANGE CODES

Range codes Range

AR 1000g

AT 5lb

AV 10lb

BL 25lb

BN 50lb

BR 100lb

CN 250lb

CR 500lb

CV 1000lb

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bondedfoil

Excitation(calibration)1kgto10lb

5Vdc

Excitation(calibration)25lbto1000lb

10Vdc

Insulationresistance 5000Mohm@50Vdc

Bridgeresistance 350ohm

Electricaltermination(std)1000gto10lb

Tefloncable(1524mm[5ft])withbal-anceboard

Electricaltermination(std)25lbto1000lb

Tefloncable(1524mm[5ft])

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximumallowableload 150%FS1

Weight Seetable

Material 17-4PHstainlesssteel

Deflectionfullscale Seetable

Naturalfrequency Seetable

WIRING CODES

Cable Unamplified

Red (+)excitation

Black (-)excitation

Green (-)output

White (+)output

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature,operating -53°Cto121°C[-65°Fto250°F]

Temperature,compensated 15°Cto71°C[60°Fto160°F]

Storagetemperature -73°Cto148°C[-100°Fto300°F]

Temperatureeffect,zero 0.005%fullscale/°F

Temperatureeffect,span 0.005%fullscale/°F

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb)

Deflection at full scale (in)

Ringing fre-quency (Hz)

Weight (g)

1000gto10lb

0,03mm[0.001in] 1000Hz 40g[0.09lb]

25lbto100lb

0,03mm[0.001in] 3000Hz 80g[0.18lb]

250lbto1000lb

0,05mm[0.0015in] 5000Hz 100g[0.22lb]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Precision Miniature Load Cell

MOUNTING DIMENSIONS

Ranges D mm [in] H mm [in] A mm [in] B mm [in] C mm [in] F mm [in] G mm [in] T

1000g,5lb,10lb 19,05[0.75] 44,45[1.75] 7,87[0.31] 4,83[0.19] 4,83[0.46] 15,24[0.60] 18,29[0.72] 1/4-28UNF

25lb,50lb,100lb 25,4[1.00] 44,45[1.75] 12,7[0.50] 6,35[0.25] 4,83[0.46] 13,21[0.52] 18,29[0.72] 1/4-28UNF

250lb,500lb,1000lb 25,4[1.00] 50,8[2.00] 12,7[0.50] 6,35[0.25] 4,83[0.46] 19,05[0.75] 19,05[0.75] 1/4-28UNF

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load range 1000g,5lb,10lb,25lb,50lb,100lb,250lb,500lb,1000lb

Temperaturecompensation

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1j.0°Cto50°C

1k.-20°Cto85°C1m.-25°to110°C71f.70°Fto250°F1g.70°Fto325°F7

1h.70°Fto400°F7

1i.-65°Fto250°F7

Internal amplifiers

2u.Unamplified,mV/Voutput

Overload stops

4a.Overloadstops

Electrical termination

6a.BendixPTIH-10-6P-6pin(max.250°F)5

6d.MicrotecDR-4S-4H4pin

6e.Integralcable:Teflon

6f. Integralcable:PVC6g.Integralcable:

Neoprene(max.180°F)

6h.Integralcable:Sili-cone

6i. Integralunderwatercable(max.180°F)

6v.Phoenixconnectoronendofcable

15d.Connectoronendofcable

Special calibration

9a.10point(5up/5down)20%increments@20°C

9b.20point(10up/10down)10%increments@20°C

Special calibration

30a. Compressiononlycalibration,positiveincompression

30b. Tensionandcompressioncalibration,posi-tiveintension

30c. Compressiononlycalibration,negativeincompression

Shock and vibration

44a.Shockandvibrationresistance

Interfaces4 53e.Signaturecalibration7

53t.TEDSIEEE1451.4module

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008636-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 34 Precision Miniature Load Cell

TYPICAL SYSTEM DIAGRAM

NOTES

1. Allowablemaximumloads–maximumloadtobeappliedwithoutdamage.2

2. Withoutdamage-loadingtothislevelwillnotcauseexcessivezeroshiftorperformancedegradation.Theusermustconsiderfatiguelifeforlongtermuseandstructuralintegrity.Allstructurallycriticalapplications(overheadloading,etc.)shouldalwaysbedesignedwithsafetyredundantloadpaths.

3. Standardcalibrationfortension/compressionloadcellsisintensiononly.

4. Option53eand53tareexternalin-lineinterfaces.5. Availabilityvarieswithrange.6. ThisunitcalibratedtoImperial(non-Metric)units.7. Notavailablewith500grange.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

198

Dimensions

Performance

Environmental

Electrical

Mechanical

Model 34 Semi Precision Miniature Load CellOrder Code AL312

www.honeywell.com/sensotec

n 50 g to 500 gn mV/V Outputn Stainless Steeln Miniature Designn Double Diaphragm Construction

ø1.00

0.52

0.52

1.75

4 conductor, 30 AWG, Teflon insulated shieldedcable, 5 ft. long with 2”spring strain relief

2x 1/4-28 UNF0.38 in. deep

Load Ranges................50; 150; 250; 500 gLinearity................+/- 0.15% Full Scale

Hysteresis................+/- 0.15% Full Scale Non-Repeatability................+/- 0.1% Full Scale

Tolerance on Output 50 to 150 g................0.1 mV/V/g max.

250 to 500 g................20 mV/VOperation................Tension/ Compression (note 3)

Resolution................Infinite

Temperature, Operating................-65° to 250° FTemperature, Compensated................60° to 160° F

Storage Temperature................-100° to 300° FTemperature, Effect

Zero................0.015% Full Scale/° FSpan................0.015% Full Scale/° F

Strain Gage Type................SemiconductorExcitation (calibration)................5 VDCInsulation Resistance................5000 Megohms @ 50 VDC

Bridge Resistance................500 Ohms Zero Balance................1% max.

Electrical Termination (std)................Teflon Cable (5 ft.)

Maximum Allowable Load................5 lb. (note 1)Weight................110 grams

Material................17-4 PH Stainless SteelDeflection Full Scale................11 kg/ mm

Natural Frequency................400 Hz

Cable/ Unamplified

Red (+) ExcitationBlack (-) ExcitationGreen (-) OutputWhite (+) Output

1-888-282-9891

Wiring Code

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

199www.honeywell.com/sensotec

Range Range Code

50 g AJ150 g AL250 g AN500 g AP

Range Codes

1-888-282-9891

In-Line Amplifiers(Used with unamplified units only)

Amplifier OutputUniversal In-Line AmplifiersUV +/- 5 VDCUV-10 +/- 10 VDCUBP 0 +/- 5 VDCU3W 4-20 mA (3 wire)DIN rail Mount In-Line AmplifiersDV-05 0 +/- 5 VDC (3 wire)DA-05 4-20 mA (3 wire)DV-10 0 +/- 10 VDC (3 wire)

Customer Supplied

Chart RecorderAlarm Panel

Data AcquisitionComputer

PLCModel 34 Semi

Model 34 semi

Model Code Range Code Options CodeSample Code: AL312 AJ 1b, 30a

Options

OEM LabelsRadiation proofDifferent cable lengths

Special Customer Requirements(Consult Factory)

Combine the order code, the range code and the options code.How to Order

Typical System Diagram

Display Units

SC500 SC1000 SC2000 SC2001 SC3004

GM NK HH

Notes

Built to Order Built from Scratch

Load Range 50; 150; 250 grams 500 grams

Temperature Compensation

1b. 30° to 130° F1c. 0° to 185° F1d. -20° to 130° F1e. -20° to 200° F1j. 0° to 50° C1k. -20° to 85° C1m. -25° to 110° C

Internal Amplifiers 2u. Unamplified, mV/V output

ElectricalTermination

6d. Microtec DR-4S-4H 4 pin6v. Phoenix connector on end of

cable

6f. Integral cable: PVC6g. Integral cable: Neoprene

(max. 180° F)6h. Integral cable: Silicone6i. Integral underwater cable

(max. 180° F)15d. Connector on end of cable

Special Calibration

30a. Compression only calibration, Positive in compression

30b. Tension and Compression calibration, Positive in tension

30c. Compression only calibration, Negative in compression

Shock & Vibration 44a. Shock and vibration resistance

Interfaces (note 4) 53e. Signature Calibration 53t. T.E.D.S. IEEE 1451.4 Module

Supplied as standard

6e. Integral cable: Teflon

1a. 60° to 160° F

1. Allowable Maximum Loads- Maximum load to be applied without damage (note 2).

2. Without Damage- loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

3. Standard calibration for tension/ compression load cells is in tension only

4. TEDS available with integral cable units only.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Subminiature Load CellModel 11

DESCRIPTIONModel 11 (tension/compression) subminiature load cell is

designed to measure load ranges from 150 g to 1000 lb. With

subminiature dimensions, including diameters from .50 in to 0.75

in and height of 0.38 in, these units are easily incorporated into

systems having limited space.

The model achieves a non-linearity and hysteresis of 0.5 % full

scale respectively and a frequency response of up to 58 kHz. A

balance module is included in the load cell’s lead wire cable for

zero balance, and should not be removed.

FEATURES• 150gto1000lb

• mV/Voutput

• Subminiaturedesign

• Singlediaphragmconstruction

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 11

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges7 150 g to 1000 lb

Linearity ±0.5 % full scale

Hysteresis ±0.5 % full scale

Non-repeatability ±0.1 % full scale

Tolerance on output 150 g to 500 g

10mV/V(nominal)

Tolerance on output1000 g to 1000 lb

2mV/V(nominal)

Operation Tension/compression3

Resolution Infinite

Maximum permissible torque 150 g to 100 lb

4 in-lb

Maximum permissible torque 250 lb to 1000 lb

20 in-lb

RANGE CODES

Range codes Range

AL 150 g

AN 250 g

AP 500 g

AR 1000 g

AT 5 lb

AV 10 lb

BL 25 lb

BN 50 lb

BR 100 lb

CN 250 lb

CR 500 lb

CV 1000 lb

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype150 g to 500 g

Semiconductor

Straingagetype 1000 g to 1000 lb

Bonded foil

Excitation (calibration) 5Vdc

Insulation resistance 5000mOhm@50Vdc

Bridge resistance (toler-ance) 150 g to 500 g

500 ohm (nominal)

Bridge resistance (toler-ance) 1000 g to 1000 lb

350 ohm (nominal)

Zero balance (tolerance) ±3 % of full scale (nominal)

Shuntcalibrationdata Included

Electrical termination (std) 1,83 m [5 ft] cable with balance board4

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load Seetable1

Weight Seetable

Material Stainlesssteel

Deflection @ full scale Seetable

Natural frequency Seetable

WIRING CODES

Cable Unamplified

Red (+) excitation

Black (-) excitation

Green (-) output

White (+) output

MOUNTING DIMENSIONS

Ranges Ø D T H A B

150, 250, 500, 1000 g; 5, 10, 25, 50, 100 lb

12,7 mm[0.50 in]

#4-40 UNC

7,37 mm [0.29 in]

4,83 mm [0.19 in]

4,57 mm[0.18 in]

250, 500, 1000 lb

19,05 mm[0.75]

1/4-28 UNF

9,65 mm[0.38 in]

7,87 mm [0.31 in]

7,87 mm [0.31 in]

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto121°C[-65°Fto250°F]

Temperature, compensated 15°Cto71°C[60°Fto160°F]

Temperature effect, zero 0.01 % full scale/°F

Temperature effect, span 0.02 % reading/°F

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Subminiature Load Cell

DEFLECTIONS AND RINGING FREQUENCIES

Capacity Deflection at full scale (10-3 in)

Ringing frequency (kHz)

Weight Weight with cable Max. allowable load1 (% FS)

150 g 0.05 10 5 g [0.011 lb] 13 g [0.029 lb] 500

250 g 0.04 14 5 g [0.011 lb] 13 g [0.029 lb] 500

500 g 0.03 22 5 g [0.011 lb] 13 g [0.029 lb] 500

1000 g 0.7 8 5 g [0.011 lb] 13 g [0.029 lb] 150

5 lb 0.6 11 5 g [0.011 lb] 13 g [0.029 lb] 150

10 lb 0.6 17 5 g [0.011 lb] 13 g [0.029 lb] 150

25 lb 0.5 24 5 g [0.011 lb] 13 g [0.029 lb] 150

50 lb 0.5 34 5 g [0.011 lb] 13 g [0.029 lb] 150

100 lb 0.5 48 5 g [0.011 lb] 13 g [0.029 lb] 150

250 lb 0.6 25 19 g [0.041 lb] 27 g [0.06 lb] 150

500 lb 0.7 33 19 g [0.041 lb] 27 g [0.06 lb] 150

1000 lb 1.0 40 19 g [0.041 lb] 27 g [0.06 lb] 150

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load range

150 g, 250 g, 500 g, 1000 g, 5 lb, 10 lb, 25 lb, 50 lb, 100 lb, 250 lb, 500 lb, 1000 lb

Tempera-turecompen-sation

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1e. -20 °F to 200 °F5

1f. 70 °F to 250 °F5

Internal amplifiers

2u.Unamplified,mV/Voutput

Electrical termina-tion

5 ft integral cable with balance board4

6a. Bendix PTIH-10-6P - (or equivalent) 6 pin (max. 120°C)onendofcable

6e. Integral cable: Teflon6v. Phoenix connector on end of cable

Electrical termina-tion orien-tation

15d.Connectoronendofcable

Special calibration

30a.Compressiontestingonly,positiveincompres-sion

30b. Tension and compression testing only, positive in tension

30c. Compressiontestingonly,negativeincompres-sion

Shock and vibration

44a.Shockandvibrationresistance

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985 Douglas Drive North

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008637-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 11 Subminiature Load Cell

TYPICAL SYSTEM DIAGRAM

NOTES

1. Allowable maximum loads – maximum load to be applied without damage.2

2. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

3. Standardcalibrationfortension/compressionloadcellsistensiononly.

4. A small, 2 in circuit board is included in the cable, 2 ft from the load cell. Do not remove this board.

5. Only for ranges greater-than-or-equal-to 1000 g.6. Specificationsmayvarywiththisoption.7. This unit calibrated to Imperial (non-Metric) units.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Subminiature Load CellModel 13

DESCRIPTIONModel 13 (compression only) subminiature load cell is designed

to measure load ranges from 150 g to 1000 lb. With subminiature

dimensions, including diameters from 0.38 in to 0.75 in and

heights of 0.13 in to 0.25 in, these units are easily incorporated

into systems having limited space. Model 13 combines high

frequency response and low deflection to achieve a combined

non-linearity and hysteresis of 0.25 % to 0.5 % full scale. A

balance module is included in the load cell’s lead wire cable for

temperature compensation and should not be removed.

FEATURES• 150gto1000lb

• 0.7%accuracy

• mV/Voutput

• Subminiaturedesign

• Singlediaphragmconstruction

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 13

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges6 150 g, 250 g, 500 g, 1000 g, 5 lb, 10 lb, 25 lb, 50 lb, 100 lb, 250 lb, 500 lb, 1000 lb

Linearity ±0.5 % full scale

Hysteresis ±0.5 % full scale

Non-repeatability ±0.1 % full scale

Tolerance on output 150 g to 500 g

15mV/V(nominal)

Tolerance on output 1000 g 1.5mV/V(nominal)

Tolerance on output5 lb to 1000 lb

2mV/V(nominal)

Operation Compressiononly

Resolution Infinite

RANGE CODES

Range codes Range

AL 150 g

AN 250 g

AP 500 g

AR 1000 g

AT 5 lb

AV 10 lb

BL 25 lb

BN 50 lb

BR 100 lb

CN 250 lb

CR 500 lb

CV 1000 lb

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype150 g to 500 g

Semiconductor

Straingagetype1000 g to 1000 lb

Bonded foil

Excitation (calibration) 5Vdc

Insulation resistance 5000mOhm@50Vdc

Bridge resistance (toler-ance)150 g to 500 g

500 ohm (nominal)

Bridge resistance (toler-ance)1000 g to 1000 lb

350 ohm (nominal)

Zero balance (tolerance) ±3 % of full scale (nominal)

Shuntcalibrationdata Included

Electrical termination (std) 1,83 m [5 ft] integral cable with balance board3

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load Seetable

Weight Seetable

Material Stainlesssteel

Deflection @ full scale Seetable

WIRING CODES

Cable Unamplified

Red (+) excitation

Black (-) excitation

Green (-) output

White (+) output

DEFLECTIONS AND RINGING FREQUENCIES

Capac-ity (lb)

Deflec-tion at full scale (10-3 in)

Weight Weight with cable

Max. al-lowable load1 (% FS)

150 g 0.06 1 g [0.002 lb] 9 g [0.019 lb] 500

250 g 0.06 1 g [0.002 lb] 9 g [0.019 lb] 500

500 g 0.08 1 g [0.002 lb] 9 g [0.019 lb] 500

1000 g 0.05 1 g [0.002 lb] 9 g [0.019 lb] 150

5 lb 0.5 1 g [0.002 lb] 9 g [0.019 lb] 150

10 lb 0.4 1 g [0.002 lb] 9 g [0.019 lb] 150

25 lb 0.4 1 g [0.002 lb] 9 g [0.019 lb] 150

50 lb 0.4 1 g [0.002 lb] 9 g [0.019 lb] 150

100 lb 0.4 3 g [0.006 lb] 11 g [0.024 lb] 150

250 lb 0.5 3 g [0.006 lb] 11 g [0.024 lb] 150

500 lb 0.5 10 g [0.022 lb] 18 g [0.039 lb] 150

1000 lb 0.6 10 g [0.022 lb] 18 g [0.039 lb] 150

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto121°C[-65°Fto250°F]

Temperature, compensated 15°Cto71°C[60°Fto160°F]

Temperature effect, zero 0.01%fullscale/°F

Temperature effect, span 0.02%reading/°F

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Subminiature Load Cell

MOUNTING DIMENSIONS

Ranges D1 D2 H B SR

150, 250, 500, 1000 g; 5, 10, 25, 50 lb

2,29 mm [0.09 in] 9,65 mm [0.38 in] 3,3 mm [0.13 in] 0,69 mm [0.027 in] 6,35 mm [0.25 in]

100, 250 lb 3,05 mm [0.12] 12,7 mm [0.50 in] 3,81 mm [0.15 in] 0,51 mm [0.020 in] 12,7 mm [0.50 in]

500 lb, 1000 lb 6,35 mm [0.25 in] 19,05 mm [0.75] 6,35 mm [0.25 in] 0,64 mm [0.025 in] 12,7 mm [0.50 in]

OPTION CODES

Many range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load range 150, 250, 500 g, 1000 g; 5, 10, 25, 50, 100, 250, 500, 1000 lb

Temperaturecompensa-tion

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto200°F

1e.-20°Fto200°F1j.0°Cto50°C1k.-20°Cto85°C1m.-25°to110°C

Internal amplifiers

2u.Unamplified,mV/Voutput

Overload stops

4a. Overload stops

Electrical termination

5 ft integral cable with balance board3

6v. Phoenix connector on end of cable15d.Connectoronendofcable

Special calibration

9a.10point(5up/5down)20%increments@68°F9b.20point(10up/10down)10%increments@68

°F

Shock and vibration

44a.Shockandvibrationresistance

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

008641-2-EN IL50 GLO April 2009Copyright © 2009 Honeywell International Inc. All rights reserved.

Model 13 Subminiature Load Cell

Sensing and Control

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422

www.honeywell.com

NOTES

1. Allowable maximum loads – maximum load to be applied without damage.2 Loads described allow for 100 % full scale axial loading with the bending loads specified. Torque loading maximum is with-outaxialorotherload.Foranyothercombination,consultfactory.

2. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

3. A small, 2 in circuit board is included in the cable, 2 ft from the load cell. Do not remove this board.

4. Only for ranges greater-than-or-equal-to 1000 g.5. Specificationsmayvarywiththisoption.6. This unit calibrated to Imperial (non-Metric) units.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthisdatasheetisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.

•Completeinstallation,operationandmaintenanceinformation is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

Find out more

Honeywell serves its customers

through a worldwide network of

sales offices, representatives

anddistributors.Forapplication

assistance, current specifica-

tions, pricing or name of the

nearest Authorized Distributor,

contact your local sales office.

To learn more about Honeywell’s

test and measurement products,

call +1-614-850-5000, visit

www.honeywell.com/sensotec,

or e-mail inquiries to

[email protected]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Top Hat Subminiature Load CellModel LFH-7I

DESCRIPTIONModel LFH-7I subminiature load cell is a low profile force

transducer for applications with minimal space and high

capacity requirements. This transducer utilizes foil strain gages

to measure compression loads of up to 10,000 lb and achieves

accuracy of ±0.7 % full scale. The top of the load cell is the area

where the force is applied and the base ring of the load cell

must be placed on a hard, machine-ground flat surface to obtain

optimum accuracy.

FEATURES• 250lbto10000lbrange

• ±0.7%accuracy

• Stainlesssteel

• Columnconstruction

• mV/Voutput

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model LFH-7I

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges4 250lbto10000lb

Accuracy ±0.7 % full scale1

Tolerance on output 1.5mV/Vto2.5mV/V

Operation Compressiononly

RANGE CODES

Range codes Range

CN 250lb

CR 500lb

CV 1000 lb

DL 2000lb

DN 3000 lb

DP 4000 lb

DR 5000lb

DT 7500lb

DV 10000 lb

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded foil

Excitation (calibration) 5Vdc

Insulation resistance 5000mOhm@50Vdc

Bridge resistance 350ohm

Zero balance 5%max.

Electrical termination (std) Cable(1,83m[5ft])

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 150%fullscale2

Weight Seetable

Material 17-4 PH stainless steel

Deflection full scale Seetable

Natural frequency Seetable

WIRING CODES

Cable Unamplified

Red (+) excitation

Black (-) excitation

Green (-) output

White (+) output

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto121°C[-65°Fto250°F]

Temperature, compensated 15°Cto71°C[60°Fto160°F]

Storagetemperature -70°Cto149°C[-100°Fto300°F]

Temperature effect, zero 0.01%fullscale/°F

Temperature effect, span 0.01%fullscale/°F(nominal)DEFLECTIONS AND RINGING FREQUENCIES

Capacity Deflection at full scale

Ringing fre-quency (kHz)

Weight

250lb 0,0127mm[0.0005in] 30 10 g [0.022lb]

500lb 0,0127mm[0.0005in] 34 10 g [0.022lb]

1000 lb 0,03mm[0.001in] 37 10 g [0.022lb]

2000lb 0,03mm[0.001in] 44 10 g [0.022lb]

3000 lb 0,03mm[0.001in] 46 10 g [0.022lb]

5000lb 0,03mm[0.001in] 47 30 g [0.066lb]

7500lb 0,038mm[0.0015in] 44 30 g [0.066lb]

10000 lb 0,04mm[0.002in] 40 30 g [0.066lb]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Top Hat Subminiature Load Cell

MOUNTING DIMENSIONS

Ranges ØD1 mm [in] ØD2 mm [in] H mm [in] F mm [in] W mm [in]

250lb 12,7[0.50] 6,86[0.27] 9,65[0.38] 3,3[0.13] 10,92[0.43]

500lb 12,7[0.50] 7,11[0.28] 9,65[0.38] 3,3[0.13] 10,92[0.43]

1000 lb 12,7[0.50] 7,87[0.31] 9,65[0.38] 3,3[0.13] 10,92[0.43]

2000lb 12,7[0.50] 10,41[0.41] 9,65[0.38] 3,3[0.13] 10,92[0.43]

3000 lb 12,7[0.50] 11,43[0.45] 9,65[0.38] 3,3[0.13] 11,68[0.46]

5000lb 16,00[0.63] 13,46[0.53] 15,24[0.60] 5,84[0.23] 12,95[0.51]

7500lb 22,35[0.88] 16,00[0.63] 16,00[0.63] 13,72[0.54] 16,00[0.63]

10000 lb 22,35[0.88] 16,00[0.63] 16,00[0.63] 13,72[0.54] 16,00[0.63]

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load range

250,500,1000,2000,3000,4000,5000,7500,10000lb

Tempera-turecompen-sation

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F1j.0°Cto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal amplifiers

2u.Unamplified,mV/Voutput

Electrical termina-tion

6e.Integralcable:Teflon6h.Integralcable:Silicone6v.Phoenixconnectoronendofcable15d.Connectoronendofcable

Special calibration

9a.10point(5up/5down)20%increments@70°F9b.20point(10up/10down)10%increments@70°F

Shock and vibration

44a.Shockandvibrationresistance

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008640-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model LFH-7I Top Hat Subminiature Load Cell

TYPICAL SYSTEM DIAGRAM

NOTES

1. Accuracies stated are expected for best-fit straight line for all errors including linearity, hysteresis and repeatability through zero.

2. Allowablemaximumloads–maximumloadtobeappliedwithoutdamage.3

3. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

4. This unit calibrated to Imperial (non-Metric) units.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Fatigue Rated Universal Load CellModel 45

DESCRIPTIONModel 45 Ultra Precision Fatigue-Rated Load Cell offers a low

profile design for both tension and compression applications.

The all-welded stainless steel construction and stabilizing

diaphragms provide the same ruggedness which has made our

Model 41 and 43 pancake type load cells so successful. The

Model 45 is available in ranges 250 lb through 100,000 lb. and

mounting dimensions are universally interchangeable within the

test and measurement industry. Options include hi-level outputs

of 4 mA to 20 mA or 0 Vdc to 5 Vdc as well as weatherproof or

submersible cable configurations.

FEATURES• Upto0.04%accuracy(seespecificationtableforspecific

range)

• 250lbto100000lb

• Longfatiguelife

• Intrinsicallysafeavailable(2Noptiononly)12

• CEapproved13

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 45

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges14 250 lb to 100000 lb

Accuracy (static er-ror band)1,2

Linearity Hysteresis

250 lb to 1000 lb ±0.04%fullscale

±0.04%fullscale

±0.03%fullscale

2500 lb to 50000 lb ±0.05%fullscale

±0.05%fullscale

±0.05%fullscale

100000 lb ±0.06%fullscale

±0.05%fullscale

±0.05%fullscale

Non-repeatability ±0.02%fullscale

Output 2 mV/V

Tolerance on output ±1%fullscale

Creepin20min.(max.) 0.01%

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]

Temperature, compensated -1 °C to 54 °C [30 °F to 130 °F]

Temperature effect, zero 0.0008%fullscale/°F

Temperature effect, span 0.0008%reading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation(calibration) 10 Vdc

Excitation(acceptable) 20 Vdc

Insulationresistance 5000 mOhm @ 50 V

Bridge resistance (tolerance)

350ohm(nominal)8

Zerobalance(tolerance) ±1%fullscale

Shuntcalibrationdata Included

Electricaltermination(std) PC02A-10-6P

Mating connector (notincluded)

PC06A-10-6S

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximumallowableload 200%FS3, 9

Weight Seetable

Case material Stainlesssteel

Lifecycles(approx.) > 108 cycles fully reversed

Deflection Seetable

Naturalfrequency Seetable

RANGE CODES

Range Code

Available ranges Range Code

Available ranges

CN 250 lb DW 12500 lb

CR 500 lb EM 25000 lb

CV 1000 lb EP 50000 lb

DM 2500 lb ET 100000 lb

DR 5000 lb

WIRING CODES

Connector Unamplified

A (+)excitation

B (+)output

C (-)output

D (-)excitation

E no connection

F no connection

BASE PLATE ORDER INFORMATION

Ranges Base plate order code

Base plate weight kg [lb]

Load button order code

250 lb to 1000 lb AA229 1,59 [3.5] AA290

2500 lb to 5000 lb

AA229 1,59 [3.5] AA290

12500 lb to 25000 lb

AA230 4,99 [11] AA291

50000 lb AA231 9,07 [20] AA292

100000 lb AA232 27,67 [61] AA293

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb) Deflection @ full scale (10-3 in)

Natural ring-ing frequen-cy (Hz)

Weight g [lb]

250 1.5 2400 1406,1 [3.1]

500 1.5 2400 1406,1 [3.1]

1000 1.5 3400 1406,1 [3.1]

2500 1 6800 1451,5 [3.2]

5000 1 9100 1451,5 [3.2]

12500 2 5700 3994,6 [8.8]

25000 2 7000 3994,6 [8.8]

50000 2 6300 9979 [22]

100000 2.5 4500 24947,58 [55]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Fatigue Rated Universal Load Cell

INTERNAL AMPLIFIERS

Amplifier specifications

Voltage out-put: Option 2b

Voltage out-put: Option 2c

Voltage out-put: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Op-tion 2n (2N)***

Output signal ±5 V 0 V to 5 V or ±5 V @ 45 mA

0 V to 10 V or ±10 V @ 45 mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage) ±15 V or 26 Vdc to 32 Vdc

11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc

9 Vdc to 28 Vdc

Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA

Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db

Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F

Reverse voltage protec-tion

Yes Yes Yes Yes Yes Yes

Short cir. protection Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)5

A(+)SupplyB Output commonCSupplyreturnD(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

Wiring code: cable5,6,7 R(+)SupplyBl Output commonGSupplyreturnW(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl(+)OutputW Case ground

R(+)SupplyBl(+)OutputW Case ground

* Black and green wires are internally connected.** Pins B and C are internally connected.***SeeourWebsiteforthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model 45

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 250, 500, 1000, 2500, 5000, 12500, 2500, 50000, 100000 lb

Temperature compensation

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F 1f. 70 °F to 250 °F

1g. 70 °F to 325 °F16

1h. 70 °F to 400 °F16

1i. -65 °F to 250 °F16

1j. 0 °C to 50 °C1k. -20 °C to 85 °C1m. -25 °C to 110 °C

Internal ampli-fiers

2b. ±5 Vdc output2c. 0 Vdc to 5 Vdc2j. 4 mA to 20 mA (three-wire)output2k.4mAto20mA(two-

wire)15

2n(2N)4mAto20mA(two-wire)intrinsicallysafe15

2t. 0 Vdc to 10 Vdc output2u. Unamplified, mV/V output

Internal amplifier enhancements

3d. Remote buffered shunt calibration

Electrical termination

PC02A-10-6P6a.BendixPTIH-10-6P(orequivalent),6-pin(max.250 °F)6b.MSconnectorMS3102E-14S-6P(mateswithMS3106E-14S-6S)(max.160°F)17

Shunt calibration

8a. Precision internal resistor16

Special calibration

9c. ASTME-74calibration30a. Compression only calibration, positive in

compression30b. Tension and compression calibration, posi-

tive in tension30c. Compression only calibration, negative in

compression30d. Tension and compression calibration, posi-

tive in compression

Bridge type 31a. Dual bridge11c.Squareandsymmetricalbridge16

Electrical connector orientation

15a.Horizontalelectricalexitportorientation

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration16

53t.TEDSIEEE1451.4module11

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl5

Fatigue Rated Universal Load Cell

MOUNTING DIMENSIONS

LOAD CELL Ranges lb

Ø D1 mm [in] H mm [in] T ØB mm [in] N mm [in] F1

250, 500, 1000, 2500, 5000

104,65 [4.12] 34,8 [1.37] 5/8-18UNF-3B 34,0 [1.34] 3,05 [0.12] 9/32 in dia., 8holeseq.sp.,3.50B.C.

12500, 25000 153,92 [6.06] 44,45 [1.75] 11/4-12UNF-3B 67,31 [2.65] 3,05 [0.12] 13/32india.,12holeseq.sp.,5.125B.C.

50000 203,2 [8.00] 63,5 [2.50] 13/4-12UNF-3B 95,50 [3.76] 6,35 [0.25] 17/32 in dia., 16holeseq.sp.,6.50B.C.

100000 279,4 [11.00] 88,9 [3.50] 23/4-8UNF-3B 122,17 [4.81] 12,7 [0.50] 11/16 in dia., 16holeseq.sp.,9.00B.C.

PULL PLATE Ranges lb

Order code ØD2 mm [in]

L mm [in] T ØG mm [in]

F2

250, 500, 1000, 2500, 5000

AA229 104,65 [4.12] 28,45 [1.12] 5/8-18UNF-3B 31,75 [1.25] 1/4-28,8holeseq.sp.,3.50B.C.

12500, 25000 AA230 153,92 [6.06] 44,45 [1.75] 11/4-12UNF-3B 57,15 [2.25] 3/8-24,12holeseq.sp.,5.125B.C.

50000 AA231 203,2 [8.00] 50,8 [2.00] 13/4-12UNF-3B 76,2 [3.00] 1/2-20,16holeseq.sp.,6.50B.C.

100000 AA232 279,4 [11.00] 76,2 [3.00] 23/4-8UNF-3B 114,3 [4.50] 5/8-18,16holeseq.sp.,9.00B.C.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008612-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 45 Fatigue Rated Universal Load Cell

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

NOTES

1. Staticerrorbandistherecommendedperformancespecifica-tion. The static error band is calculated as the best fit straight line through zero, including the effects of non-linearity, hysteresis and non-repeatability.

2. Values noted are typical values but fall within the static error.3. Allowablemaximumloads–maximumloadtobeappliedwithout

damage.4 4. Withoutdamage-loadingtothislevelwillnotcauseexcessivezero

shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications(overheadloading,etc.)shouldalwaysbedesignedwith safety redundant load paths.

5. Interconnectingshuntcal.1terminalwithshuntcal.2terminalprovides50%(unamplifiedunits),75%(4mAto20mAthree-wireunits)or80%(voltageamplifiedunits)offullscaleoutputforquickcalibration.Shuntcalibrationcomesstandardwithinternalamplifieroption 2c, 2t and 2j.

6. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector.

7. Nomatingconnectornecessaryforcableoption.8. 250 lb. range has 700 ohm bridge resistance.9. Offaxisloadingmaximumallowable50%fullscale.10. Internalamplifierforrangeslessthan12,500lbmayincreasein

height.11. ConsultfactoryforTEDSavailabilitywithamplifiedmodels.12. Range dependent; consult factory. Termination dependent; consult

factory.13. Internalampandterminationdependent;consultfactory.14. ThisunitcalibratedtoImperial(non-Metric)units.15. 5000ohmbridgerequired.16. Cannot be used with amplified option.17. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Model 47 is available in ranges 250 lb through 100,000 lb. and

mounting dimensions are universally interchangeable within the

industry. Options include hi-level outputs of 4 mA to 20 mA or

0 Vdc to 5 Vdc as well as weatherproof or submersible cable

configurations.

Fatigue Rated Ultra PrecisionUniversal Load Cell

Model 47

DESCRIPTIONModel 47 Ultra Precision Fatigue Rated Load Cell offers a low

profile design for both tension and compression applications.

The all welded stainless steel construction and stabilizing

diaphragms provide the same ruggedness which has made our

Model 41 and 43 pancake type load cells so successful. The

FEATURES• Accuracy up to 0.02 % (see specification table for specific

range)

• 250 lb to 100000 lb

• Long fatigue life

• Pull plate attached

• Intrinsically safe available (2N option only)12

• CE approved13

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2 Honeywell • Sensing and Control

Model 47

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges14 250 lb to 100000 lb

Accuracy (static er-ror band)1,2

Linearity Hysteresis

250 lb to 1000 lb ±0.02 % full scale

±0.02 % full scale

±0.02 % full scale

2500 lb to 5000 lb ±0.03 % full scale

±0.03 % full scale

±0.04 % full scale

12500 lb to 50000 lb ±0.04 % full scale

±0.04 % full scale

±0.05 % full scale

100000 lb ±0.05 % full scale

±0.05 % full scale

±0.05 % full scale

Non-repeatability ±0.01 % full scale

Output 2.0 mV/V

Tolerance on output ±1 % full scale

Creep in 20 min. (max.) 0.01 %

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]

Temperature, compensated -1 °C to 54 °C [30 °F to 130 °F]

Temperature effect, zero 0.0008 % full scale/°F

Temperature effect, span 0.0008 % reading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Foil

Excitation (calibration) 10 Vdc

Excitation (acceptable) 20 Vdc

Insulation resistance 5000 mOhm @ 50 V

Bridge resistance (tolerance)

350 ohm (nominal)8

Zero balance (tolerance) ±1 % full scale

Shunt calibration data Included

Electrical termination (std) PC02A-10-6P

Mating connector (not included)

PC06A-10-6S

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 200 % FS 3, 9

Weight See table

Case material Stainless steel

Life cycles (approx.) > 108 cycles fully reversed

Deflection See table

Natural frequency See table

RANGE CODES

Range Code

Available ranges Range Code

Available ranges

CN 250 lb DW 12500 lb

CR 500 lb EM 25000 lb

CV 1000 lb EP 50000 lb

DM 2500 lb ET 100000 lb

DR 5000 lb

WIRING CODES

Connector Unamplified

A (+) excitation

B (+) output

C (-) output

D (-) excitation

E no connection

F no connection

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb) Deflection @ full scale (10-3 in)

Natural ring-ing frequen-cy (Hz)

Weight g [lb]

250 1.5 2400 2,99 [6.6]

500 1.5 2400 2,99 [6.6]

1000 1.5 3400 2,99 [6.6]

2500 1 6800 3,04 [6.7]

5000 1 9100 3,04 [6.7]

12500 2 5700 8,98 [19.8]

25000 2 7000 8,98 [19.8]

50000 2 6300 19,05 [42]

100000 2.5 4500 52,62 [116]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell • Sensing and Control 3

Fatigue Rated Ultra Precision Universal Load Cell

INTERNAL AMPLIFIERS

Amplifier specifications

Voltage out-put: Option 2b

Voltage out-put: Option 2c

Voltage out-put: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Op-tion 2n (2N)***

Output signal ±5 V 0 V to 5 V or ±5 V @ 45 mA

0 V to 10 V or ±10 V @ 45 mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage) ±15 V or 26 Vdc to 32 Vdc

11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc

9 Vdc to 28 Vdc

Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA

Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db

Operating temp. -20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F

Reverse voltage protec-tion

Yes Yes Yes Yes Yes Yes

Short cir. protection Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)5

A (+) SupplyB Output commonC Supply returnD (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return **D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB Output common**C Supply return**D (+) OutputE Shunt cal 1F Shunt cal 2

A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection

A (+) SupplyB No connectionC No connectionD (+) OutputE Case groundF No connection

Wiring code: cable5,6,7 R (+) SupplyBl Output commonG Supply returnW (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl Output common*G Supply return*W (+) OutputB Shunt cal 1Br Shunt cal 2

R (+) SupplyBl (+) OutputW Case ground

R (+) SupplyBl (+) OutputW Case ground

* Black and green wires are internally connected.** Pins B and C are internally connected.*** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00.

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4 Honeywell • Sensing and Control

Model 47

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honey-well.com/TMsensor-ship for updated listings.

Load ranges 250, 500, 1000, 2500, 5000, 12500, 2500, 50000, 100000 lb

Temperature compensation

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F 1f. 70 °F to 250 °F

1g. 70 °F to 325 °F16

1h. 70 °F to 400 °F16

1i. -65 °F to 250 °F16

1j. 0 °C to 50 °C1k. -20 °C to 85 °C1m. -25 °C to 110 °C

Internal ampli-fiers

2b. ±5 Vdc output2c. 0 Vdc to 5 Vdc2j. 4 mA to 20 mA

(three-wire) output2k. 4 mA to 20 mA (two-

wire)15

2n (2N) 4 mA to 20 mA (two-wire) intrinsi-cally safe15

2t. 0 Vdc to 10 Vdc output

2u. Unamplified, mV/V output

Electrical termination

6a. Bendix PTIH-10-6P (or equivalent) 6-pin (max. 250 °F)

6b. MS connector MS3102E-14S-6P (mates with MS3106-14S 6P) (max. 160 °F)17

6e. Integral cable: Teflon

6f. Integral cable: PVC6g. Integral cable:

Neoprene6

6h. Integral cable: Silicone

6i. Integral underwater cable

6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable

6q. Molded integral ca-ble: Polyurethane

6v. Phoenix connector on end of cable

15d. Connector on end of cable

Shunt calibration

8a. Precision internal resistor16

Special calibration

9a. 10 point (5 up/5 down) 20 % increments @ 70 °F

9b. 20 point (10 up/10 down) 10 % increments @ 70 °F

9c. ASTM E-74 calibration9e. CE mark30a. Compression only calibration, positive in com-

pression30b. Tension and compression calibration, positive

in tension30c. Compression only calibration, negative in

compression30d. Tension and compression calibration, positive in

compression

Bridge type 31a. Dual bridge11a. Square bridge16

11c. Square and symmetrical bridge16

Bridge resistance

12b. 5000 ohm (foil) (max 250 °F)

Electrical connector orientation

15a. Horizontal electrical exit port orientation15b. Vertical electrical exit port orientation15c. Radial electrical exit port orientation

Shock and vibration

44a. Shock and vibration resistance

Interfaces 53e. Signature calibration16

53t. TEDS IEEE 1451.4 module11

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell • Sensing and Control 5

Fatigue Rated Ultra Precision Universal Load Cell

MOUNTING DIMENSIONS

LOAD CELL Ranges lb

Ø D1 mm [in] H mm [in] T ØB mm [in] N mm [in] ØG mm [in]

250, 500, 1000, 2500, 5000

104,65 [4.12] 34,8 [1.37] 5/8-18 UNF-3B 34,0 [1.34] 3,05 [0.12] 31,75 [1.25]

12500, 25000 153,92 [6.06] 44,45 [1.75] 1 1/4-12 UNF-3B 67,31 [2.65] 3,05 [0.12] 57,15 [2.25]

50000 203,2 [8.00] 63,5 [2.50] 1 3/4-12 UNF-3B 95,50 [3.76] 6,35 [0.25] 76,2 [3.00]

100000 279,4 [11.00] 88,9 [3.50] 2 3/4-8 UNF-3B 122,17 [4.81] 12,7 [0.50] 114,3 [4.50]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008613-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 47 Fatigue Rated Ultra Precision Universal Load Cell

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

NOTES

1. Static error band is the recommended performance specifica-tion. The static error band is calculated as the best fit straight line through zero, including the effects of non-linearity, hysteresis and non-repeatability.

2. Values noted are typical values but fall within the static error.3. Allowable maximum loads – maximum load to be applied without damage.4

4. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

5. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2c, 2t and 2j.

6. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector.

7. No mating connector necessary for cable option.8. 250 lb range has 700 ohm bridge resistance.9. Off axis loading maximum allowable 50% full scale.10. Internal amplifier for ranges less than 12500 lb may increase in

height.11. Consult factory for TEDS availability with amplified models.12. Range dependent; consult factory. Termination dependent; consult

factory.13. Internal amp and termination dependent; consult factory.14. This unit calibrated to Imperial (non-Metric) units.15. 5000 ohm bridge required.16. Cannot be used with amplified option.17. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Precision Fatigue-Rated Low Profile Load Cell

Model 73

DESCRIPTIONModel 73 fatigue-rated load cells are engineered for applications

such as materials or product fatigue testing, which involve an

extremely large number of cycles or occasional overload condi-

tions. These fatigue rated load cells have load ranges from 50

lbs to 200,000 lbs and achieve a non-linearity of 0.1% full scale.

The superior design of these bonded foil, strain gage compres-

sion load cells permits a fatigue life of 1 billion cycles (zero to full

scale). Model 73 measures compression only. It must be used

on a smooth flat surface to achieve rated specifications. The

load button on Model 73 is an integral part of the load cell and

cannot be removed or changed. Model 73 utilizes two stabilizing

diaphragms, which are welded to the sensing member to reduce

off-center and side-loading effects.

FEATURES• 0.10%accuracy

• 50lbto200000lb

• mV/Voutput(standard);4mAto20mAor0Vdcto5Vdc

(optional) output

• Stainlesssteel

• Doublediaphragmdesign

• Enhancedoverloadcapacity

• Intrinsicallysafeavailable(2Noptiononly)7

• CEapproved8

Approved Approved ApprovedIntrinsically safe amp

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 73

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges9 50 lb to 200000 lb

Non-linearity ±0.1 % full scale

Hysteresis ±0.1 % full scale

Non-repeatability ±0.03 % full scale

Output (tolerance) 2mV/V±0.5%fullscale

Operation Compression

Resolution Infinite

Standardcalibration5-point calibration, 0 %, 50 %, and 100 %F.S.incompressiononly

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto121°C[-65°Fto250°F]

Temperature, compensated 15°Cto71°C[60°Fto160°F]

Temperature effect, zero 0.002%fullscale/°F

Temperature effect, span 0.002%fullscale/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded foil

Excitation(calibration) 10Vdc

Insulation resistance 5000mOhm@50Vdc

Bridge resistance (tolerance)

350 ohm (nominal)

Zero balance (tolerance) ±1 % full scale

Shuntcalibrationdata Included

Electricaltermination(std)50 lb to 2000 lb

PTIH-10-6P

Electricaltermination(std)3000 lb to 200000 lb

MS3102E-14S-6P

Mating connector 50 lb to 2000 lb (not incl.)

PT06A-10-6Sorequiv.(AA111)

Mating connector 3000 to 200000 lb (not incl.)

MS3106A-14S-6S(AA121)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 200%FS2

Weight Seetable

Material 17-4PHstainlesssteel

Life cycles (approx) > 108 cycles fully reversed

Deflection Seetable

Naturalfrequency Seetable

RANGE CODES

Range Code

Available ranges Range Code

Available ranges

BN 50 lb DV 10000 lb

BR 100 lb EJ 15000 lb

CN 250 lb EL 20000 lb

CR 500 lb EN 30000 lb

CV 1000 lb EP 50000 lb

DL 2000 lb ER 75000 lb

DN 3000 lb ET 100000 lb

DP 4000lb FJ 150000 lb

DR 5000 lb FL 200000 lb

DT 7500 lb

WIRING CODES

Connector Unamplified (Std.)

A (+) excitation

B (+) excitation

C (-) excitation

D (-) excitation

E (-) output

F (+) output

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb) Deflection @ full scale (in)

Natural ringing frequency (Hz)

Weight g (lb)

50 to 500 0.001 4500 730[1.6]

1000 to 2000 0.002 8000 952,54[2.1]

3000 to 10000 0.002 9000 2948,35[6.5]

15000 to 50000 0.003 10000 2993,70 [6.6]

75000 to 100000 0.004 13000 5443,10[12.0]

150000 to 200000 0.006 11000 12020,19 [26.5]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Precision Fatigue-Rated Low Profile Load Cell

INTERNAL AMPLIFIERS

Amplifier specifications

Voltage out-put: Option 2a

Voltage out-put: Option 2c

Voltage out-put: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Op-tion 2n (2N)***

Output signal 0Vto5V 0Vto5Vor±5V@45mA

0Vto10Vor±10V@45mA

4mAto20mA 4mAto20mA 4mAto20mA

Input power (voltage) ±15Vor26Vdcto32Vdc

11Vdcto28Vdc 15Vdcto28Vdc 22Vdcto32Vdc 15Vdcto 40Vdc

9Vdcto 28Vdc

Input power (current) 45mA 40mA 40mA 65mA 4mAto28mA 4mAto24mA

Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rej. 60db 60db 60db 60db 60db 60db

Operating temp. -20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F

Reverse voltage protec-tion

Yes Yes Yes Yes Yes Yes

Short cir. protection Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)4

A(+)SupplyB Output commonCSupplyreturnD(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

Wiring code: cable4,5,6 R(+)SupplyBl Output commonGSupplyreturnW (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl (+) OutputWCaseground

R(+)SupplyBl (+) OutputWCaseground

* Black and green wires are internally connected.**PinsBandCareinternallyconnected.***SeeourWebsiteforthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.

ALLOWABLE MAXIMUM LOADS2

Capacity (lb) Side load (% FS)

Bending (lb-in)

Torque (lb-ft)

50 to 500 75 % 60% 35 %

1000 to 2000 45% 35 % 35 %

3000 to 10000 30 % 30 % 35 %

15000 to 50000 30 % 30 % 25 %

75000 to 100000 30 % 30 % 15 %

150000 to 200000 30 % 30 % 15 %

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model 73

OPTION CODES

Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 50,100,250,500,1000,2000,3000,4000,5000,7500,10000,15000,20000,30000,50000,75000,100000,150000,200000lb

Temperature compensa-tion

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F

1g.70°Fto325°F12

1h.70°Fto400°F12

1i.-65°Fto250°F12

1j.0°Fto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal amplifiers

2b.Four-wire,0Vdcto5Vdcoutput2c.0Vdcto5Vdc2j.4mAto20mA(three-wire)output2k.4mAto20mA(two-wire)11

2n(2N)4mAto20mA(two-wire)intrinsicallysafe11

2t.0Vdcto10Vdcoutput2u.Unamplified,mV/Voutput

Internal amplifier en-hancements

3a.Input/outputisolation10

3d. Remote buffered shunt calibration8

Electrical termination

6a.BendixPTIH-10-6P(orequivalent),6-pin(max.250°F)6b.MSconnectorMS3102E-14S-6P(mateswithMS3106E-14S-6S)(max.160°F)(ranges2000andabove)13

6e.Integralcable:Teflon

6f.Integralcable:PVC6g.Integralcable:Neoprene6h.Integralcable:Silicone6i.Integralunderwatercable6j.1/2-14conduitfittingwith5ftof4conductorPVCcable

Shunt calibration

8a. Precision internal resistor12

Bridge resistance

12b.5000ohm(foil)(max.250°F)

Bridge type 31a.Dualbridge

Zero and span adjust-ment

14a.Noaccesstopots14b.Topaccesstopots

Electrical connector orientation

15a. Horizontal electrical exit port orientation15b.Verticalelectricalexitportorientation15c. Radial electrical exit port orientation15d.Connectoronendofcable

Special calibration

30a.Compressiononly,positiveoutput9a.10point(5up/5down)20%increments@70°F9b.20point(10up/10down)10%increments@70°F9c.ASTME-74calibration

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration12

53t.TEDSIEEE1451.4module6

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl5

Precision Fatigue-Rated Low Profile Load Cell

MOUNTING DIMENSIONS

Ranges lb

D1 mm [in]

D2 mm [in] H mm [in]

ØF type. dia.

G mm [in] B.C.

A mm [in]

A* mm [in]

B mm [in] B* mm [in]

C mm [in]

50 to 500 76,2[3.00] 14,22[0.56] 29,97 [1.18]

1/4 57,15 [2.250]

20,83 [0.82]

63,5[2.5] 19,05[0.75] 22,86[0.9] 31,75[1.25]

1000 to 2000

88,9[3.50] 17,53[0.69] 29,97 [1.18]

5/16 66,68[2.625]

20,83 [0.82]

63,5[2.5] 19,05[0.75] 22,86[0.9] 31,75[1.25]

3000 to 10000

114,3[4.50]

38,1[1.50] 50,8[2.00] 3/8 46,27[3.790]

31,75 [1.25]

58,42[2.3] 38,1[1.50] 38,1[1.5] 50,8[2.00]

15000 to 50000

114,3[4.50]

38,1[1.50] 50,8[2.00] 3/8 46,27[3.790]

31,75 [1.25]

58,42[2.3] 38,1[1.50] 38,1[1.5] 50,8[2.00]

75000 to 100000

139,7 [5.50]

50,8[2.00] 55,37 [2.18]

3/8 122,22 [4.812]

31,75 [1.25]

58,42[2.3] 38,1[1.50] 38,1[1.5] 50,8[2.00]

150000 to 200000

190,5 [7.50]

63,5[2.50] 68,1[2.68] 3/8 171,45[6.750]

31,75 [1.25]

58,42[2.3] 38,1[1.50] 38,1[1.5] 50,8[2.00]

* Length of load cell with amplified option (see option codes)

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008628-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 73 Precision Fatigue-Rate Low Profile Load Cell

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed tootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

NOTES

1. Allowablemaximumloads-maximumloadtobeappliedwithoutdamage.2

2. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue lifeforlongtermuseandstructuralintegrity.Allstructurallycriticalapplications (overhead loading, etc.) should always be designed with safety redundant load paths.

3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides50%(unamplifiedunits),75%(4mAto20mAthree-wireunits)or80%(voltageamplifiedunits)offullscaleoutputforquickcalibration.Shuntcalibrationcomesstandardwithinternalamplifieroption 2a, 2b, 2c, 2t and 2j.

4. O=Orange;Y=Yellow;B=Blue;Bl=Black; R=Red;Br=Brown;W=White;G=Green.Colorspecifyingcableandnumberorletter

specifying connector. 5. Nomatingconnectornecessaryforcableoption.6. ConsultfactoryforTEDSavailabilitywithamplifiedmodels.7. Rangedependent;consultfactory.Terminationdependent;consult

factory.8. Internalampandterminationdependent;consultfactory.9. This unit calibrated to Imperial (non-Metric) units.10. Input/outputisolationonlyavailablewithvoltageoutput(2bor2c)

amplifier.11. 5000ohmbridgerequired.12. Cannotbeusedwithamplifiedoption.13. Cannotbeusedwithoptions1c,1e,1f,1g,1g,or1i.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Low Capacity Fatigue Load CellModels 3149-FR

DESCRIPTIONThe 3149-FR tension/compression load cells are designed for

demanding applications in automotive, aerospace and military

markets.

This model is offered in capacity ratings of 50, 100 and 300 lb.

Standard output is 2.0 mV/V with an overall accuracy of 0.05%.

The sensors have a nominal bridge resistance of 350 ohm and

can be powered by up to 15 Vac or Vdc. Safe overload range is

150% of rated capacity.

The load cells are offered with optional dual bridge output to

provide force feedback and control or redundancy.

FEATURES• Fatiguerated

• Compactsize

• Highaccuracy

• Tensionandcompression

• Dualbridgeoutput

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3179-FR

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load range1 50, 100, 300 lbf

Zero balance ±1.0 % of rated output

Non-linearity ±0.05 % of rated output

Hysteresis ±0.05 % of rated output

Non-repeatability ±0.01 % of rated output

Static error band ±0.05 % of rated output

Creep ±0.03 % (reading in 20 minutes)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated -9°Cto46°C[15°Fto115°F]

Temperature effect, sensitivity

0.08 % reading/100 °F

Temperatureeffect,zero 0.15 % of rated output/100 °F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Excitation (recommended) 10 Vdc

Input resistance 700 ohm, +40/-3.5 ohm

Output resistance 700 ohm ±3.5 ohm

Sensitivity (rated output) 2 mV/V (nominal)

Insulation resistance, bridge/case

5000 mOhm @ 50 Vdc

MECHANICAL SPECIFICATIONS

Characteristic Measure

Safe overload range 150 % of rated output

Weight 0.8 lb

Flexure material Aluminum

WIRING CODES

Cable

Red (+) excitation

Black (-) excitation

Green (+) output

White (-) output

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output Input

Serial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3149FR

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

AmplifierUniversal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

SC500 SC1000 SC2000SC2001 SC3004GM NK HH7541 7558 7561-PSD

Display Units

OR

A

2.36

0.03, 2 PLACES1.50

1/4-28 UNF, 0.28 DEEP, 2 PLACES[FOR METRIC VERSION: m6 X 1.0, 7.1 DEEP, 2 PLACES]

Ø0.692 PLACES

2.56 R

OPTIONAL DUAL BRIDGE

Ø2.75

MOUNTING DIMENSIONS

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008620-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3179-FR Low Capacity Fatigue Load Cell

NOTES

1. This unit calibrated to Imperial (non-Metric) units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression Pancake Load CellModel 3108

DESCRIPTIONThese general purpose designs have exceptional structural

capability to withstand extraneous loads, such as torque,

bending moments, and side loads. This low-range cell has built-

in temperature compensation.

Available in capacities of five and ten pounds, they offer

maximum performance and enhanced accuracy.

Minimum deflection and compactness make these general-

purpose load cells easy to install and use.

FEATURES• 5lbto10lbrange

• 0.05%accuracy

• Lowsensitivitytoextraneousloads

• Lowdeflection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3108

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadrange1 5,10lb

Non-linearity ±0.01%ofratedoutput

Hysteresis ±0.01%ofratedoutput

Repeatability ±0.05%ofratedoutput

Output @ rated capacity 2mV/V±0.25%(nominal)

Operation Tension/compression

Resolution Infinite

Standardcalibration Tension(+)andcompression(-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated 21°Cto77°C[70°Fto170°F]

Temperature effect, zero ±0.002%ofratedoutput/°F

Temperature effect, output ±0.002%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation(maximum) 20VdcorVacRMS

Insulation resistance >5000mOhm@50Vdc

Bridge resistance (tolerance)

350ohm

Number of bridges 1or2

Zero balance ±1.0%

Electrical termination PT02E-10-6PmateswithPT06W-10-6S

MECHANICAL SPECIFICATIONS

Characteristic Measure

Staticoverloadcapacity 150%ofnominalcapacity

Material Carbonsteel

Natural frequency Seetable

WIRING CODES

Cable

Red (+)excitation

Black (-)excitation

Green (+)output

White (-)output

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3108

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

OR

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Tension/Compression Pancake Load Cell

NATURAL FREQUENCYNominal load limit capacity Fz

Static extraneous load limits

lb N Static over-load capacity (% of nominal capacity)

Shear FX or FY (lb)

Bending MX or MY (lb-in)

Torque MZ (lb-in)

Deflection at nominal load limit (in)

Ringing fre-quency (Hz)

5 20 150 30 30 3 0.005 500

10 50 150 40 40 4 0.005 900

Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in]

3108 6,98[2.75] 0,55[0.22] 0,32[0.13] 4,44[1.75] 5,60[2.22] -[1/4-28]

G cm [in] H cm [in] J cm [in] K cm [in] L cm [in] N cm [in] P cm [in]

1,27[0.38] 1,10[0.44] 0,71[0.28] 3,80[1.50] 0,16[0.06] 4,13[1.63] 2,54[1.00]

NOTE:the3108mountingconfigurationissimilartothe3397.

A

D

H DIA.

N DIA.

P

CJ

K

L

E

SPANNER WRENCHHOLE B DIA.C DEEPF THD.

G DEEPBOTH ENDS

RECEP.PTO2E-10-6P

DUAL BRIDGEOPTIONAL

MOUNTING DIMENSIONS

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008621-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3108 Tension/Compression Pancake Load Cell

NOTES

1.ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliterature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression Pancake Load CellModel 3132

DESCRIPTIONThese general purpose designs have exceptional structural

capability to withstand extraneous loads, such as torque,

bending moments, and side loads.

Available in capacities of 500 lb to 5000 lb, they offer maximum

performance and enhanced accuracy.

Minimum deflection and compactness make these general-

purpose load cells easy to install and use.

FEATURES• 500lbto5000lbrange

• Lowsensitivitytoextraneousloads

• Lowdeflection

• Ruggedweldedconstruction

• Built-intemperaturecompensation

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3132

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadrange1 500, 1000, 2000, 3000, 5000 lb

Non-linearity ±0.1 % of rated output

Hysteresis ±0.1 % of rated output

Repeatability ±0.05 % of rated output

Output @ rated capacity 3 mV/V ±0.25 % (nominal)

Operation Tension/compression

Resolution Infinite

Standardcalibration Tension (+) and compression (-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated 21°Cto77°C[70°Fto170°F]

Temperature effect, zero ±0.002%ofratedoutput/°F

Temperature effect, output ±0.002%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation (maximum) 20VdcorVacRMS

Insulation resistance > 5000 mOhm @ 50 Vdc

Bridgeresistance(tolerance)

350 ohm

Number of bridges 1 or 2

Zero balance ±1.0 %

Electrical termination PT02E-10-6PmateswithPT06W-10-6S

MECHANICAL SPECIFICATIONS

Characteristic Measure

Staticoverloadcapacity 150 % of nominal capacity

Material Carbonsteel

Natural frequency Seetable

WIRING CODES

Cable

Red (+) excitation

Black (-) excitation

Green (+) output

White (-) output

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3132

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

OR

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Tension/Compression Pancake Load Cell

NATURAL FREQUENCYNominal load limit capacity Fz

Static extraneous load limits

lb N Static over-load capacity (% of nominal capacity)

Shear FX or FY (lb)

Bending MX or MY (lb-in)

Torque MZ (lb-in)

Deflection at nominal load limit (in)

Ringing fre-quency (Hz)

500 2K 150 1400 2800 1100 0.005 1600

1K 5K 150 2000 3900 1100 0.005 2000

2K 10K 150 2800 5000 1100 0.005 3200

3K 15K 150 3400 5500 1100 0.005 4100

5K 20K 150 4200 5500 1100 0.005 5000

Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in]

3132 6,65[2.62] 1,60[0.63] 8,89[3.50] 2,54[1.0] 3,02[1.19] 4,45[1.75]

G cm [in] H cm [in] J cm [in] K cm [in] L cm [in]

0,64[0.25] 8,70[0.34] 5,08[2.0] 3,33[1.31] 2,54[1.0]

MOUNTING DIMENSIONS

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008624-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3132 Tension/Compression Pancake Load Cell

NOTES

1. This unit calibrated to Imperial (non-Metric) units.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliterature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression Pancake Load CellModels 3140-CS

DESCRIPTIONThe Model 3140-CS load cell series has been designed as

a reference standard for calibration labs in automotive,

aerospace, military or industrial markets. These tension/

compression load cells can be used when accuracy is a high

priority requirement. Some advantages of these load cells are:

compact size, high accuracy and availability.

FEATURES• Enhancedaccuracy,upto0.02%

• 300lbto100000lbrange

• Universaltensionandcompressionloading

• Lowprofile

• 150%fullscalesafeoverloadcapability

• Availableinsingleoroptionaldualbridgeconfiguration

• Metricsizesavailable

• Factoryinstalledcalibrationadapters

• Eccentricloadcompensated

• Highprecisionbaseinstalled

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3140-CS

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadrange1 300,500,1000,2000,5000,10000,25000,50000,100000

Operation Tension/compression

Resolution Infinite

Standard calibration Tension (+) and compression (-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated -9°Cto46°C[15°Fto115°F]

Temperature effect, zero 0.08%ofratedoutput/100°F

Temperature effect, output 0.08%ofreading/100°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Foil

Excitation(maximum) 10 Vdc or Vac RMS

Insulation resistance >5000mOhm@50Vdc

Input resistance (tolerance) 350ohm±40/-3.5ohm

Output resistance (tolerance)

350ohm±3.5ohm

Zero balance (tolerance) ±1.0%

Electricaltermination PT02E-10-6PmateswithPT06W-10-6S

MECHANICAL SPECIFICATIONS

Characteristic Measure

Static overload capacity 150%ofnominalcapacity

Material Carbon steel

Creep ±0.01%

Off-centered load sensitivity 300lbto2Klb

±0.10%

Off-centered load sensitivity 5Klbto100Klb

±0.25%

Side load sensitivity 300lbto2Klb

±0.10%

Side load sensitivity5Klbto100Klb

±0.25%

WIRING CODES

Cable

Red (+)excitation

Black (-)excitation

Green (+) output

White (-) output

TYPICAL SYSTEM DIAGRAM300 lb to 2K lb

5K lb to 10K lb

25K lb to 100K lb

Non-linearity error (of full scale)

±0.02% ±0.04% ±0.04%

Hysteresiserror(offull scale)

±0.02% ±0.04% ±0.05%

Non-repeatability (of full scale)

±0.005% ±0.005% ±0.005%

Output@ratedca-pacity (nominal)

2.0mV/V 4.0 mV/V 4.0 mV/V

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3143CS

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

OR

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Tension/Compression Pancake Load Cell

TYPICAL SYSTEM DIAGRAM TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3144CS

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

OR

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3145CS

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

OR

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model 3140-CS

MOUNTING DIMENSIONS

Model Capacity (lb)

Ø A in

B in C in D in E in F in G in Ø H in J Thread Ø K in L Thread M in.

3143-CS-300 300 4.12 0.13 1.25 2.50 3.44 4.18 0.03 1.25 1/2-20UNF3A 6.00 1/2-20UNF3B 0.88

3143-CS-500 500 4.12 0.13 1.25 2.50 3.44 4.18 0.03 1.25 1/2-20UNF3A 6.00 1/2-20UNF3B 0.88

3143-CS-1K 1000 4.12 0.13 1.25 2.50 3.44 4.18 0.03 1.25 1/2-20UNF3A 6.00 1/2-20UNF3B 0.88

3143-CS-2K 2000 4.12 0.13 1.25 2.50 3.44 4.18 0.03 1.25 1/2-20UNF3A 6.00 1/2-20UNF3B 0.88

3144-CS-5K 5000 4.12 0.13 1.25 2.50 3.44 4.19 0.03 1.25 5/8-18UNF3A 6.00 5/8-18UNF3B 0.88

3144-CS-10K 10000 4.12 0.13 1.25 2.50 3.44 4.19 0.03 1.25 5/8-18UNF3A 6.00 5/8-18UNF3B 0.88

3145-CS-25K 25000 6.06 0.13 1.63 3.50 4.94 6.44 0.03 1.25 1¼-12UNF3A 6.00 1¼-12UNF3B 1.50

3145-CS-50K 50000 6.06 0.13 1.63 3.50 4.94 6.44 0.03 2.25 1¼-12UNF3A 6.00 1¼-12UNF3B 1.50

3146-CS-100K 100000 8.00 0.25 2.25 4.50 6.13 7.88 0.03 3.00 1¾-12UNF3A 12.00 1¾-12UNF3B 1.75

Ø K R

Ø A

BC

D

E

F

G

Ø H

J THD. L THD.M DEEP

RECEP.PT02E-10-6P

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Sensing and Control

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008626-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3140-CS Tension/Compression Pancake Load Cell

NOTES

1. This unit calibrated to Imperial (non-Metric) units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3146CS

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

OR

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression Pancake Load CellModels 3140-P

DESCRIPTIONDesigned for general purpose use in demanding applications in

automotive, aerospace, and military applications. Some advan-

tages of these tension/compression load cells include compact

size, high accuracy, and cost efficiency. The 3140-P has smaller

maximum off-center load and moment error than the standard

3140 Series.

FEATURES• Staticerrorband0.02%to0.04%

• Englishthreads

• Enhancedaccuracyversionofstandard3140Series

• Lowprofile

• Lowsensitivitytomagneticfields

• Outputto4mV/V

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3140-P

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadrange1 300lb,500lb,1000lb,2000lb,5000lb,10000lb,25000lb,50000lb,100000lb

Non-linearity300lbto2Klb ±0.02%ofratedoutput

Non-linearity 5Klbto100Klb

±0.04%ofratedoutput

Hysteresis ±0.02%ofratedoutput

Non-repeatability ±0.01%ofratedoutput

Staticerrorband300lbto2Klb

±0.02%ofratedoutput

Staticerrorband5Klbto10Klb

±0.03%ofratedoutput

Staticerrorband25Klbto100Klb

±0.04%ofratedoutput

Output@ratedcapacity 4mV/V(nominal)

Operation Tension/compression

Resolution Infinite

Standardcalibration Tension(+)andcompression(-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated -9°Cto46°C[15°Fto115°F]

Temperature effect, zero ±0.008%ofratedoutput/°F

Temperature effect, output ±0.008%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Foil

Excitation(maximum) 10VdcorVacRMS

Insulation resistance >5000mOhm@50Vdc

Inputresistance(tolerance) 350ohm+40/-3.5ohm

Outputresistance(tolerance)

350ohm±3.5ohm

Sensitivity300lbto2Klb 2mV/Vofratedoutput

Sensitivity5Klbto100Klb 4mV/Vofratedoutput

Zerobalance(tolerance) ±1.0%

MECHANICAL SPECIFICATIONS

Characteristic Measure

Static overload capacity 150%ofnominalcapacity

Material Seetableonnextpage

Creep ±0.03%

Off-centeredloadsensitivity ±0.10%

Side load sensitivity ±0.10%

WIRING CODES

Cable

Red (+)excitation

Black (-)excitation

Green (+)output

White (-)output

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3143P

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

OR

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Tension/Compression Pancake Load Cell

TYPICAL SYSTEM DIAGRAM TYPICAL SYSTEM DIAGRAM

MECHANICAL CHARACTERISTICSNominal load limit capacity Fz

Model lb N Static overload capacity (% of nominal capacity)

Weight (lb) Weight with base (lb)

Flexure material

3143-P 300 1K 150 1.0 2.5 Aluminum

3143-P 500 2K 150 1.0 2.5 Aluminum

3143-P 1K 5K 150 1.0 2.5 Aluminum

3143-P 2K 10K 150 1.0 2.5 Aluminum

3144-P 5K 22K 150 2.9 6.5 Steel

3144-P 10K 45K 150 2.9 6.5 Steel

3145-P 25K 110K 150 9.1 21.5 Steel

3145-P 50K 200K 150 9.1 21.5 Steel

3146-P 100K 500K 150 23.5 52.5 Steel

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3144P

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

OR

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3145P

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

OR

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model 3140-P

MOUNTING DIMENSIONS

Model Capac-ity (lb)

Ø A in Ø B in C in D in E Thread

F in G in Ø H J in K Thread

L in

3143-P-300 300 4.12 1.29 0.13 2.50 1/2-20UNF3B

1.12 1.25 1.25 0.03 1/2-20UNF3B

0.88

3143-P-500 500 4.12 1.29 0.13 2.50 1/2-20UNF3B

1.12 1.25 1.25 0.03 1/2-20UNF3B

0.88

3143-P-1K 1000 4.12 1.29 0.13 2.50 1/2-20UNF3B

1.12 1.25 1.25 0.03 1/2-20UNF3B

0.88

3143-P-2K 2000 4.12 1.29 0.13 2.50 1/2-20UNF3B

1.12 1.25 1.25 0.03 1/2-20UNF3B

0.88

3144-P-5K 5000 4.12 1.29 0.13 2.50 5/8-18UNF3B

1.12 1.25 1.25 0.03 5/8-18UNF3B

0.88

3144-P-10K 10000 4.12 1.29 0.13 2.50 5/8-18UNF3B

1.12 1.25 1.25 0.03 5/8-18UNF3B

0.88

3145-P-25K 25000 6.06 2.34 0.13 3.50 1¼-12UNF3B

1.50 1.63 1.25 0.03 1¼-12UNF3B

1.50

3145-P-50K 50000 6.06 2.58 0.13 3.50 1¼-12UNF3B

1.50 1.63 2.25 0.03 1¼-12UNF3B

1.50

3146-P-100K

100000 8.00 3.76 0.25 4.50 1¾-12UNF3B

2.25 2.25 3.00 0.03 1¾-12UNF3B

1.75

PT02E-10-6P CONNECTOR

J

L DEEPK THD.

D

Ø H

G

C

F DEEPE THD.

Ø BØ A

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008625-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3140-P Tension/Compression Pancake Load Cell

NOTES

1.ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3146P

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

OR

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression Pancake Load CellModel 3167

DESCRIPTIONThese general purpose designs have exceptional structural

capability to withstand extraneous loads, such as torque,

bending moments, and side loads.

Available in capacities of 25 lb to 300 lb, they offer maximum

performance and enhanced accuracy.

Minimum deflection and compactness make these general-

purpose load cells easy to install and use.

FEATURES• Up to 0.05 % accuracy

• 25 lb to 300 lb range

• Integral cable (standard)

• Low sensitivity to extraneous loads

• Low deflection

• Built-in temperature compensation

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2 Honeywell • Sensing and Control

Model 3167

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load range1 25, 50, 100, 200, 300 lb

Non-linearity ±0.05 % of rated output

Hysteresis ±0.05 % of rated output

Repeatability ±0.02 % of rated output

Output @ rated capacity 2 mV/V ±0.25 % (nominal)

Operation Tension/compression

Resolution Infinite

Standard calibration Tension (+) and compression (-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]

Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F]

Temperature effect, zero ±0.002 % of rated output/°F

Temperature effect, output ±0.002 % of reading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Foil

Excitation (maximum) 20 Vdc or Vac RMS

Insulation resistance > 5000 mOhm @ 50 Vdc

Bridge resistance (tolerance)

350 ohm

Number of bridges 1

Zero balance ±5.0 %

Electrical termination 15 ft of Belden 8723 four-conductor shielded cable

MECHANICAL SPECIFICATIONS

Characteristic Measure

Static overload capacity 150 % of nominal capacity

Material Carbon steel

Natural frequency See table

WIRING CODES

Cable

Red (+) excitation

Black (-) excitation

Green (+) output

White (-) output

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3167

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

OR

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell • Sensing and Control 3

Tension/Compression Pancake Load Cell

NATURAL FREQUENCYNominal load limit capacity Fz

Static extraneous load limits

lb N Static over-load capacity (% of nominal capacity)

Shear FX or FY (lb)

Bending MX or MY (lb-in)

Torque MZ (lb-in)

Deflection at nominal load limit (in)

Ringing fre-quency (Hz)

25 125 150 150 150 40 0.003 2100

50 200 150 150 150 40 0.003 2800

100 500 150 250 180 40 0.003 3800

200 1K 150 250 180 40 0.003 5400

300 1.5K 150 250 180 40 0.003 7000

Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in]

3167 5,72 [2.25] - [1/4-28] 0,95 [0.38] 1,10 [0.44] 1,10 [0.44]

F cm [in] G cm [in] G cm [in] J cm [in] K cm [in]

0,24 [0.09] 3,80 [1.50] 0,16 [0.06] 4,44 [1.75] 6,98 [2.75]

MOUNTING DIMENSIONS

E

J DIA.

K DIA.

F

G

H

D

A +/- H

B UNF THD.C DEEP BOTH ENDS

FOUR COND. SHIELD CABLEBELDEN 8723

15 FEET

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008622-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3167 Tension/Compression Pancake Load Cell

NOTES

1. This unit calibrated to Imperial (non-Metric) units.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression Pancake Load CellModel 3173

DESCRIPTIONThe Model 3173 covers the lower capacity ranges of 200

pounds force to 3000 pounds force, while exhibiting the high

performance characteristics of stiffness and accuracy. These

load cells are well suited to materials testing machines and other

applications requiring a rugged load sensor. Often ideal for high

cycle count applications.

FEATURES• Englishthreads

• Enhancedaccuracy,0.07%

• Lowdeflection

• Fatigue-resistantdesignandenhancedperformance

• Lowfull-scalecapacity

• Lowprofile

• Decreasedsensitivitytoextraneousloading

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3173

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadrange1 200, 500, 1K, 2K, 3K lb

Accuracy 0.07%

Non-linearity ±0.05%ofratedoutput

Hysteresis ±0.05%ofratedoutput

Repeatability ±0.02%ofratedoutput

Output @ rated capacity (200 lb to 1K lb)

1.50 mV/V (nominal)

Output @ rated capacity (2K lb to 3K lb)

2.00 mV/V (nominal)

Operation Tension/compression

Resolution Infinite

Standardcalibration Tension(+)andcompression(-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated 21°Cto77°C[70°Fto170°F]

Temperature effect, zero ±0.002%ofratedoutput/°F

Temperature effect, output ±0.002%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation(maximum) 20VdcorVacRMS

Insulation resistance > 5000 mOhm @ 50 Vdc

Input resistance 700 ohm

Output resistance 700 ohm

Zero balance ±1.0%

Electricaltermination PT02E-10-6P

MECHANICAL SPECIFICATIONS

Characteristic Measure

Staticoverloadcapacity 150%ofnominalcapacity

Material Carbonsteel

Fatiguelife(0tofullfatigueload)

100 x 106 cycles

Fatiguelife(fullfatigueten-sion to compression)

50 x 106 cycles

Natural frequency Seetable

WIRING CODES

Cable

Red (+) excitation

Black (-)excitation

Green (+) output

White (-)output

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3173

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

064-LW31684-1

Recommended Tension Base

OR

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Tension/Compression Pancake Load Cell

NATURAL FREQUENCYNominal load limit capacity Fz

Static extraneous load limits

lb N Static overload capacity (% of nominal capac-ity)

Shear FX or FY (lb)

Bending MX or MY (lb-in)

Torque MZ (lb-in)

Deflection at nominal load limit (in)

Ringing fre-quency (Hz)

200 1K 150 100 4471 185 0.003 1500

500 2K 150 100 15625 466 0.003 2440

1K 5K 150 100 15500 911 0.003 3900

2K 10K 150 100 4000 2133 0.001 5500

3K 15K 150 100 5166 2818 0.001 7200

MOUNTING DIMENSIONS

Mo

del

Cap

acit

y N

[lb

]

A c

m [

in]

B c

m [

in]

C c

m [

in]

D c

m [

in]

E c

m [

in]

F c

m [

in]

G t

hre

ads

En

glis

h

H c

m [

in]

I cm

[in

]

No

. of

ho

les

J

Bo

ltin

g

scre

ws

K

L c

m [

in]

M c

m [

in]

N c

m [

in]

O c

m [

in]

P c

m [

in]

Q c

m [

in]

3173

900-13

.5K

[200

-3K] 10,47

[4.12]7,24[2.85]

3,23 [1.27]

3,48[1.37]

0,31 [0.12]

0,15 [0.06]

5/8-18

UNF-3B 8.89

[3.5]0,71 [0.28]

8

1/4-28

hex

head

* 3,18 [1.25]

1,27 [0.50]

0,08 [0.03]

2,87 [1.13]

2,21 [0.87]

0,64[0.25]

*tightento200in-lbs

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008618-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3173 Tension/Compression Pancake Load Cell

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your orderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywell during the period of coverage, Honeywell will repair orreplace,atitsoption,withoutchargethoseitemsitfindsdefective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

NOTES

1.ThisunitcalibratedtoImperial(non-Metric)units.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression Pancake Load CellModels 3174-3176

DESCRIPTIONModels 3174, 3175, and 3176 are fatigue-resistant, low-profile

tension and compression load cells that are well suited to

materials testing machines and other applications requiring

a rugged load sensor, while exhibiting the high performance

characteristics of stiffness and accuracy.

These load cells are extremely resistant to extraneous bending

and side-loading forces. The structure virtually eliminates

bending strains at the strain gage, minimizing the primary cause

of load cell failures.

FEATURES• Englishthreads

• Enhancedaccuracy,upto0.07%

• Lowdeflection

• Fatigue-resistantdesignandenhancedperformance

• Tension/compressioncapacity

• Lowprofile

• Lowsensitivitytoextraneousloading

Model 3174

Model 3174 with tension base

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3174-3176

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadrange1 5K,10K,20K,50K,100Klb

Non-linearity ±0.05%ofratedoutput

Hysteresis ±0.05%ofratedoutput

Repeatability ±0.02%ofratedoutput

Output @ rated capacity 2.00mV/V(nominal)

Creep ±0.025%ofratedoutput

Resolution Infinite

Standardcalibration Tension(+)andcompression(-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated 21°Cto77°C[70°Fto170°F]

Temperature effect, zero ±0.002%ofratedoutput/°F

Temperature effect, output ±0.002%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation(maximum) 20VdcorVacRMS

Insulation resistance >5000mOhm@50Vdc

Bridge resistance 700ohm

Number of bridges 1

Zero balance ±1.0%

Electricaltermination PT02E-10-6P

MECHANICAL SPECIFICATIONS

Characteristic Measure

Staticoverloadcapacity 150%ofnominalcapacity

Material Carbonsteel

Fatiguelife(0tofullfatigueload)

100x106 cycles

Fatiguelife(fullfatigueten-siontocompression)

50x106 cycles

Natural frequency Seetable

WIRING CODES

Cable

Red (+)excitation

Black (-)excitation

Green (+)output

White (-)output

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output Input

Serial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3174

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

AmplifierUniversal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

4-20mA (3 wire)4-20mA (2 wire)

4-20mA (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000SC2001 SC3004GM NK HH7541 7558 7561-PSD

Display Units

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

064-LW30774-1

Recommended Tension Base

OR

±5 Vdc±10 Vdc0 ±5 Vdc

0 ±5 Vdc (3 wire)

0 ±10 Vdc (3 wire)

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Tension/Compression Pancake Load Cell

NATURAL FREQUENCYNominal load limit capacity Fz

Static extraneous load limits

Model lb N Static overload capacity (% of nominal capacity)

Fatigue capacity (% of nominal capacity)

Shear FX or FY (lb)

Bending MX or MY (lb-in)

Torque MZ (lb-in)

Deflection at nominal load limit (in)

Ringing frequency (Hz)

3174 5K 20K 150 100 11K 9K 12K 0.001 6500

3174 10K 50K 150 100 25K 27K 24K 0.001 7200

3174 20K 100K 150 100 55K 58K 35K 0.001 8600

3175 50K 200K 150 100 32K 33K 67K 0.001 12000

3176 100K 500K 150 100 78K 147K 196K 0.001 15000

HoneywellIn-Line Amplifier

Output Input

Serial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3175

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

AmplifierUniversal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

4-20mA (3 wire)4-20mA (2 wire)

4-20mA (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000SC2001 SC3004GM NK HH7541 7558 7561-PSD

Display Units

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

064-LW31496-1

Recommended Tension Base

OR

0 ±5 Vdc

±5 Vdc±10 Vdc

0 ±5 Vdc (3 wire)

0 ±10 Vdc (3 wire)

HoneywellIn-Line Amplifier

Output Input

Serial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3176

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

AmplifierUniversal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

4-20mA (3 wire)4-20mA (2 wire)

4-20mA (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000SC2001 SC3004GM NK HH7541 7558 7561-PSD

Display Units

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

064-LW31496-2

Recommended Tension Base

OR

±5 Vdc±10 Vdc0 ±5 Vdc

0 ±5 Vdc (3 wire)

0 ±10 Vdc (3 wire)

TYPICAL SYSTEM DIAGRAM TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model 3174-3176

MOUNTING DIMENSIONSModel Ca-

pacity N [lb]

A cm [in]

B cm [in]

C cm [in]

D cm [in]

E cm [in]

F cm [in]

G cm [in]

H cm [in]

Tap thru I English

J cm [in]

K cm [in]

No. of holes L

Bolting M English

3174 20K-100K[5K-20K]

15,39[6.06]

10,99[4.33]

6,35 [2.42]

4,45 [1.75]

0,310[0.12]

0,13[0.05]

5,72 [2.25]

2,06[0.81]

1¼-12 UNF-3B

13,02[5.13]

10,3[13/32]

12 3/8-24hexhead,2¼inches long, tighten to 750in-lb

3175 200K[50K]

20,32[8.00]

13,15 [5.18]

7,98[3.14]

6,35 [2.50]

0,30[0.12]

0,08[0.03]

7,98[3.14]

n/a 1¾-12 UN-3B

16,51 [6.50]

13,50[17/32]

16 ½-20hexhead,33/8inlong,tightento120ft-lb,grade 8 bolts

3176 500K[100K]

27,94[11.00]

18,02[7.09]

12,50[4.92]

8,89[3.50]

0,30[0.12]

0,08[0.03]

12,50[4.92]

n/a 2¾-8 UN-3B

22,86 [9.00]

16,70[21/32]

16 5/8-18hexhead,45/8inlong,tightento290ft-lb, grade 8 bolts

*tightento200in-lbs

G

K DIA. THRU L NUMBER OF HOLESEQUALLY SPACED M RECOMMENDEDBOLTING SCREWS

RECEP.PT02E-10-6P (MATING

CONNECTOR FURNISHED)

A DIA.

B DIA.

C DIA.

F

E

D

J BOLT CIRCLE

45

A

F

D

H

Tension bases are recommended for all model 3174, 3175 and 3176 applications.When mounting without the tension base, attention must be given to the matingsurface with regard to flatness, hardness and stiffness.

I TAP THRU

16

MODEL3174ONLY

2.25 INCH5.12 CM

I TAP THRU

THIS SURFACE FLAT TO0.0005 INCH TIR AND

FINISH TO 64 MAX

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008619-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3174-3176 Tension/Compression Pancake Load Cell

NOTES

1.ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression Pancake Load CellModel 3397

DESCRIPTIONThese general purpose designs have exceptional structural

capability to withstand extraneous loads, such as torque,

bending moments, and side loads.

Available in capacities of 25 lb to 300 lb, they offer maximum

performance and enhanced accuracy.

Minimum deflection and compactness make these general-

purpose load cells easy to install and use.

FEATURES• Upto0.05%accuracy

• 25lbto300lbrange

• Lowsensitivitytoextraneousloads

• Lowdeflection

• Built-intemperaturecompensation

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3397

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadrange1 25, 50, 100, 200, 300 lb

Non-linearity ±0.05%ofratedoutput

Hysteresis ±0.05%ofratedoutput

Repeatability ±0.02%ofratedoutput

Output @ rated capacity 2mV/V±0.25%(nominal)

Operation Tension/compression

Resolution Infinite

Standardcalibration Tension(+)andcompression(-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated 21°Cto77°C[70°Fto170°F]

Temperature effect, zero ±0.002%ofratedoutput/°F

Temperature effect, output ±0.002%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation(maximum) 20VdcorVacRMS

Insulation resistance > 5000 mOhm @ 50 Vdc

Bridgeresistance(tolerance)

350 ohm

Number of bridges 1 or 2

Zero balance ±5.0%

Electrical termination PT02E-10-6PmateswithPT06W-10-6S

MECHANICAL SPECIFICATIONS

Characteristic Measure

Staticoverloadcapacity 150%ofnominalcapacity

Material Carbonsteel

Natural frequency Seetable

WIRING CODES

Cable

Red (+)excitation

Black (-)excitation

Green (+)output

White (-)output

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output Input

Serial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3397

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

AmplifierUniversal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000SC2001 SC3004GM NK HH7541 7558 7561-PSD

Display Units

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

OR

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Tension/Compression Pancake Load Cell

NATURAL FREQUENCYNominal load limit capacity Fz

Static extraneous load limits

lb N Static over-load capacity (% of nominal capacity)

Shear FX or FY (lb)

Bending MX or MY (lb-in)

Torque MZ (lb-in)

Deflection at nominal load limit (in)

Ringing fre-quency (Hz)

25 125 150 150 150 40 0.003 2100

50 200 150 150 150 40 0.003 2800

100 500 150 250 180 40 0.003 3800

200 1K 150 250 180 40 0.003 5400

300 1.5K 150 250 180 40 0.003 7000

Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in]

3397 6,98[2.75] 0,55[0.22] 0,32[0.13] 4,44[1.75] 5,60[2.22] -[1/4-28]

G cm [in] H cm [in] J cm [in] K cm [in] L cm [in] N cm [in] P cm [in]

1,27[0.50] 1,10[0.44] 0,24[0.09] 3,80[1.50] 0,16[0.06] 4,44[1.75] 2,54[1.00]

MOUNTING DIMENSIONS

A

D

H DIA.

N DIA.

J

K

L

P

C

E

SPANNER WRENCHHOLE B DIA.C DEEPF THD.

G DEEPBOTH ENDS

RECEP.PTO2E-10-6P

DUAL BRIDGEOPTIONAL

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008623-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3397 Tension/Compression Pancake Load Cell

NOTES

1.ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliterature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression Canister Load CellModel 3127

FEATURES• Optionaldualbridgenotshown

• Englishthreads(metricthreadsavailable:3127-118)

• Resistfatiguefailure

• Lowfailurerate

• Multi-beamstructuredesign

• 10000000Ncapacity

• Bendingmomentresistanceof7500000lbinches

• 450000lbofshearresistance

DESCRIPTIONTheModel3127fatigue-resistantloadcellsareextremely

resistanttoextraneousbendingandsideloadingforces.The

structurevirtuallyeliminatesbendingstrainsatthestraingage,

minimizingtheprimarycauseofloadcellfailure.Dualbridge

optionavailableforfeedbackcontrolandredundancy.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3127

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadrange1 10MN

Non-linearity ±0.2%ofratedoutput

Hysteresis ±0.2%ofratedoutput

Repeatability ±0.05%ofratedoutput

Output@ratedcapacity ±2mV/V(nominal)

Operation Tension/compression

Resolution Infinite

Standardcalibration Tension(+)andcompression(-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature,operating -54°Cto93°C[-65°Fto200°F]

Temperature,compensated 21°Cto77°C[70°Fto170°F]

Temperatureeffect,zero ±0.003%ofratedoutput/°F

Temperatureeffect,output ±0.003%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation(maximum) 20VdcorVacRMS

Insulationresistance >5000mOhm@50Vdc

Bridgeresistance(tolerance)

700ohm

Numberofbridges 1or2

Zerobalance ±1.0%

Electricaltermination MS-3102E-14S-5P

MECHANICAL SPECIFICATIONS

Characteristic Measure

Staticoverloadcapacity 150%ofnominalcapacity

Material Carbonsteel

Fatiguelife(0tofullfatigueload)

100x106cycles

Fatiguelife(fullfatigueten-siontocompression)

50x106cycles

Naturalfrequency Seetable

WIRING CODES

Wire

Red (+)excitation

Black (-)excitation

Green (+)output

White (-)output

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output Input

Serial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3127

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

AmplifierUniversal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000SC2001 SC3004GM NK HH7541 7558 7561-PSD

Display Units

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

OR

064-LW13621 Mating connector7200-76-XX* Mating connector and six conductor cable (unamplified unit with sense leads but not shunt cal)7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable (unamplified sensor without sense leads)7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable for connection to 7541 7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable for connection to 7541

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Tension/Compression Canister Load Cell

NATURAL FREQUENCYNominal load limit capacity Fz

Static extraneous load limits

lb N Static overload capacity (% of nominal capacity)

Fatigue capacity (% of nominal capacity)

Shear FX or FY (lb)

Bending MX or MY (lb-in)

Torque MZ (lb-in)

Deflection at nominal load limit (in)

Ringing frequency (Hz)

2000K 10M 100 50 450K 7500K 1500K 0.007 1900

Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in] G cm [in] H cm [in] J cm [in]

3127 57,15[22.50]

20,32[8.0] 16,51[6.50] 6,35[2.50] 44,78[17.63]

43,18[17] 28,58[11.25]

16,51[6.50] 24,77[9.75]

K cm [in] L cm [in] M cm [in] N cm [in] P cm [in] Q cm [in] R cm [in] S cm [in] *T cm [in] *U cm [in]

7,62[3] 30,48[12] 3,81[1.50] 6,35[2.50] 8,89[3.50] 20,96[8.25] 1,03[0.41] 1,27[0.50] M150-4[6-8]

M42-3[1.75-12]

*3127-118•TandUaremetricthreadmeasures*3127standard•TandUareEnglishthreadmeasures

MOUNTING DIMENSIONS

K DIA.

T THD.Q DEEP

BOTH ENDS

JG

H DIA.BOTH ENDS

N

3/4-10 THD.M DEEP 2 HOLESAT 180 LIFTING

C

D

F DIA.BOTH ENDS

E

B A

U THD. P DEEP, 12 HOLESEQUALLY SPACED ON L DIA.

BOTH ENDS

SPANNER WRENCH HOLESR DIA. S DEEP 6 HOLES

EQUALLY SPACED BOTH ENDS

RECEP.MS-3102E-14S-5P

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008646-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3127 Tension/Compression Canister Load Cell

NOTES

1.ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression Canister Load CellModel 3129-121

FEATURES• Optionaldualbridge(notshown)

• Metricthreads(Englishthreadsavailble:3129-112)

• Resistfatiguefailure

• Multi-beamstructuredesign

• 1500000Ncapacity

• Bendingmomentresistanceof840000lbinches

• 65000lbofshearresistance

DESCRIPTIONTheModel3129-121fatigue-resistantloadcellsareextremely

resistanttoextraneousbendingandsideloadingforces.The

structurevirtuallyeliminatesbendingstrainsatthestraingage,

minimizingtheprimarycauseofloadcellfailure.Dualbridge

optionavailableforfeedbackcontrolandredundancy.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3129-121

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadrange1 750000,1000000,1500000N

Non-linearity ±0.2%ofratedoutput

Hysteresis ±0.2%ofratedoutput

Repeatability ±0.05%ofratedoutput

Output@ratedcapacity ±2mV/V(nominal)

Operation Tension/compression

Resolution Infinite

Standardcalibration Tension(+)andcompression(-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature,operating -54°Cto93°C[-65°Fto200°F]

Temperature,compensated 21°Cto77°C[70°Fto170°F]

Temperatureeffect,zero ±0.003%ofratedoutput/°F

Temperatureeffect,output ±0.003%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation(maximum) 20VdcorVacRMS

Insulationresistance >5000mOhm@50Vdc

Bridgeresistance(tolerance)

350ohm

Numberofbridges 1or2

Zerobalance ±1.0%

Electricaltermination MS-3102E-14S-5P

MECHANICAL SPECIFICATIONS

Characteristic Measure

Staticoverloadcapacity 150%ofnominalcapacity

Material Carbonsteel

Fatiguelife(0tofullfatigueload)

100x106cycles

Fatiguelife(fullfatigueten-siontocompression)

50x106cycles

Naturalfrequency Seetable

WIRING CODES

Wire

Red (+)excitation

Black (-)excitation

Green (+)output

White (-)output

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output Input

Serial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3127

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

AmplifierUniversal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000SC2001 SC3004GM NK HH7541 7558 7561-PSD

Display Units

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

OR

064-LW13621 Mating connector7200-76-XX* Mating connector and six conductor cable (unamplified unit with sense leads but not shunt cal)7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable (unamplified sensor without sense leads)7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable for connection to 7541 7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable for connection to 7541

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Tension/Compression Canister Load Cell

NATURAL FREQUENCYNominal load limit capacity Fz

Static extraneous load limits

lb N Static overload capacity (% of nominal capacity)

Fatigue capacity (% of nominal capacity)

Shear FX or FY (lb)

Bending MX or MY (lb-in)

Torque MZ (lb-in)

Deflection at nominal load limit (in)

Ringing frequency (Hz)

150K 750K 150 75 40K 625K 150K 0.004 3000

200K 1M 150 75 55K 730K 260K 0.004 3400

300K 1.5M 150 75 65K 840K 236K 0.004 4100

Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in]

3129 25,4[10] 17,78[7] 3,81[1.50] 10,8[4.25] 19,05[7.50] 12,70[5]

G cm [in] H cm [in] J cm [in] K cm [in] L cm [in] *M cm [in] *N cm [in]

6,35[2.50] 12,7[5] 3,81[1.50] 13,97[5.50] 8,41[3.31] M27-2[1-8] M76-2[3-12]

*3129-121•MandNaremetricthreadmeasures*3129-112standard•MandNareEnglishthreadmeasures

MOUNTING DIMENSIONS

SPANNER WRENCH HOLES13/32 DIA. 3/8 DEEP

6 HOLES EQUALLY SPACEDAT BOTH ENDS

RECEP.MS-3102E-14S-5P

A

K

J

E

L DIA.

B DIA.

C

D

N THD.3.0 DEEP

BOTH ENDS

G

F

M THD. 1/2 DEEP8 HOLES EQUALLY SPACEDON H DIA.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008647-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3129-121 Tension/Compression Canister Load Cell

NOTES

1.ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression Canister Load CellModel 3130-131

DESCRIPTIONThe Model 3130-131 fatigue-resistant load cells are extremely

resistant to extraneous bending and side loading forces. The

structure virtually eliminates bending strains at the strain gage,

minimizing the primary cause of load cell failure. Dual bridge

option available for feedback control and redundancy.

FEATURES• Optionaldualbridge(notshown)

• Metricthreads

• Resistfatiguefailure

• Multi-beamstructuredesign

• Capacitiesto5000000N

• Bendingmomentresistanceupto6110000lbinches

• Upto180000lbofshearresistance

• Flexiblemountingconfigurations

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3130-131

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load range1 2M,3.5M,5MN

Non-linearity ±0.2 % of rated output

Hysteresis ±0.2 % of rated output

Repeatability ±0.05%ofratedoutput

Output@ratedcapacity ±2mV/V(nominal)

Operation Tension/compression

Resolution Infinite

Standardcalibration Tension(+)andcompression(-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated 21°Cto77°C[70°Fto170°F]

Temperature effect, zero ±0.003%ofratedoutput/°F

Temperature effect, output ±0.003%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation(maximum) 20VdcorVacRMS

Insulation resistance >5000mOhm@50Vdc

Bridgeresistance(tolerance)

700ohm

Numberofbridges 1 or 2

Zero balance ±1.0 %

Electrical termination MS-3102E-14S-5P

MECHANICAL SPECIFICATIONS

Characteristic Measure

Staticoverloadcapacity 150%ofnominalcapacity

Material Carbonsteel

Fatiguelife(0tofullfatigueload)

100 x 106 cycles

Fatiguelife(fullfatigueten-siontocompression)

50x106 cycles

Naturalfrequency Seetable

WIRING CODES

Wire

Red (+)excitation

Black (-)excitation

Green (+)output

White (-)output

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output Input

Serial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3130

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

AmplifierUniversal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000SC2001 SC3004GM NK HH7541 7558 7561-PSD

Display Units

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

OR

064-LW13621 Mating connector7200-76-XX* Mating connector and six conductor cable (unamplified unit with sense leads but not shunt cal)7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable (unamplified sensor without sense leads)7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable for connection to 7541 7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable for connection to 7541

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Tension/Compression Canister Load Cell

NATURAL FREQUENCYNominal load limit capacity Fz

Static extraneous load limits

lb N Static overload capacity (% of nominal capacity)

Fatigue capacity (% of nominal capacity)

Shear FX or FY (lb)

Bending MX or MY (lb-in)

Torque MZ (lb-in)

Deflection at nominal load limit (in)

Ringing frequency (Hz)

500K 2M 150 50 94K 4530K 820K 0.006 2500

800K 3.5M 150 50 180K 5450K 1050K 0.006 3100

1000K 5M 150 50 180K 6110K 1100K 0.006 3600

Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in] G cm [in]

3130 31,75[12.50] 3,81[1.50] 17,78[7.0] 5,08[2.0] 1,91[0.75] 32,29[12.75] 31,12[12.25]

H cm [in] J cm [in] K cm [in] L cm [in] M cm [in] N cm [in] P cm [in] *Q cm [in] *R cm [in]

15,88[6.25] 13,34[5.25] 2,54[1.0] 19,86[7.82] 6,35[2.50] 24,15[9.50] 8,89[3.50] M42-3[1.75-12] M125-4[5-8]

*3130-131•QandRaremetricthreadmeasures*3130standard•QandRareEnglishthreadmeasures

MOUNTING DIMENSIONS

Q THD. 2.0 DEEP8 HOLES EQUALLY SPACED

ON N DIA. BOTH ENDS

R THD.P DEEP

BOTH ENDS

1.0

H

3/8 16 THD. 5/8 DEEP2 HOLES AT 180 LIFTING

E

D

B

C A

G DIA. BOTH ENDS

F DIA.

L

M

J DIA. BOTH ENDS

RECEP.MS-3102E-14S-5P

SPANNER WRENCH HOLES 13/32 DIA. 3/8 DEEP 4 HOLESEQUALLY SPACED BOTH ENDS

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008644-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3130-131 Tension/Compression Canister Load Cell

NOTES

1.ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression Canister Load CellModel 3156

FEATURES• Englishthreads(metricconfigurationavailable:3156-133)

• Resistfatiguefailure

• Minimizebendingstrains

• Dualbridgesavailableonallmodels

• Multi-beamstructuredesign

• Enhancedresistancetosideloadsandbendingmoments

DESCRIPTIONTheModel3156fatigue-resistantloadcellsareextremely

resistanttoextraneousbendingandsideloadingforces.The

structurevirtuallyeliminatesbendingstrainsatthestraingage,

minimizingtheprimarycauseofloadcellfailure.Dualbridge

optionavailableforfeedbackcontrolandredundancy.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3156

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadrange1 100K,200K,500K,750KN

Non-linearity ±0.2%ofratedoutput

Hysteresis ±0.2%ofratedoutput

Repeatability ±0.05%ofratedoutput

Output@ratedcapacity ±2mV/V(nominal)

Operation Tension/compression

Resolution Infinite

Standardcalibration Tension(+)andcompression(-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature,operating -54°Cto93°C[-65°Fto200°F]

Temperature,compensated 21°Cto77°C[70°Fto170°F]

Temperatureeffect,zero ±0.003%ofratedoutput/°F

Temperatureeffect,output ±0.003%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation(maximum) 30VdcorVacRMS

Insulationresistance >5000mOhm@50Vdc

Bridgeresistance(tolerance)

350ohm

Numberofbridges 1or2

Zerobalance ±1.0%

Electricaltermination MS-3102E-14S-5P

MECHANICAL SPECIFICATIONS

Characteristic Measure

Staticoverloadcapacity 150%ofnominalcapacity

Material Carbonsteel

Fatiguelife(0tofullfatigueload)

100x106cycles

Fatiguelife(fullfatigueten-siontocompression)

50x106cycles

Naturalfrequency Seetable

WIRING CODES

Wire

Red (+)excitation

Black (-)excitation

Green (+)output

White (-)output

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output Input

Serial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3156

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

AmplifierUniversal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000SC2001 SC3004GM NK HH7541 7558 7561-PSD

Display Units

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

OR

064-LW13621 Mating connector7200-76-XX* Mating connector and six conductor cable (unamplified unit with sense leads but not shunt cal)7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable (unamplified sensor without sense leads)7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable for connection to 7541 7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable for connection to 7541

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Tension/Compression Canister Load Cell

NATURAL FREQUENCYNominal load limit capacity Fz

Static extraneous load limits

lb N Static overload capacity (% of nominal capacity)

Fatigue capacity (% of nominal capacity)

Shear FX or FY (lb)

Bending MX or MY (lb-in)

Torque MZ (lb-in)

Deflection at nominal load limit (in)

Ringing frequency (Hz)

25K 100K 150 100 2K 68K 10K 0.003 2100

50K 200K 150 100 6K 130K 20K 0.003 3000

100K 500K 150 100 10K 220K 85K 0.003 4200

150K 750K 150 100 20K 220K 85K 0.003 4800

Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in] G cm [in]

3156 17,78[7] 13,97[5.50] 8,89[3.50] 5,41[2.13] 12,07[4.75] 2,87[1.13] 13,84[5.45]

H cm [in] J cm [in] K cm [in] L cm [in] M cm [in] N cm [in] P cm [in] *R cm [in]

9,12[3.59] 8,89[3.50] 0,79[0.31] 0,95[0.38] 5,08[2] 3,18[1.25] M20x2.5[3/4-10] M52x2[2-12]

*3156-133•PandRaremetricthreadmeasures*3156standard•PandRareEnglishthreadmeasures

MOUNTING DIMENSIONS

P THD. N DEEP 6 HOLESEQUALLY SPACED ON J DIA.BOTH ENDS

RECEP.MS-3102E-14S-5P

H

R THD.M DEEPBOTH ENDS

SPANNER WRENCH HOLESL DIA. K DEEP3 HOLES EQUALLY SPACEDBOTH ENDS

G

C

AE

F

DDIA.

B

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008645-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3156 Tension/Compression Canister Load Cell

NOTES

1.ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Rod End In-line Tension Load CellModel RF

DESCRIPTIONModel RF, with female threads, is a high output rod end load cell

designed to be mounted inline to the load axis to measure ten-

sion. The outputs for these load cells are ±5 Vdc or 10 Vdc, or

4 mA to 20 mA (two wire) all calibrated in tension. The mount-

ing thread configurations and the all welded stainless steel

construction make these tension load cells ideal for a variety of

rugged field applications as well as in the laboratory.

The optional high output signal offers resistance to electrical

noise as well as additional signal resolution. Additional options

include an internal buffered shunt calibration circuit for ease of

setup with an associated indicator, and a variety of thread selec-

tions, including metric sizes.

FEATURES• 2000lbto200000lbrange

• Female/femalethreads

• Stainlesssteel,all-weldedconstruction

• 0Vdcto5Vdcor4mAto20mAoutputs

• Upto0.15%linearity

• CEapproved10

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model RFPERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges12 2000 lb to 200000 lb

Linearity100 lb to 1000 lb

±0.2%fullscale

Linearity2000 lb to 50000 lb

±0.15%fullscale

Linearity75000 lb to 20000 lb

±0.2%fullscale

Hysteresis100 lb to 1000 lb

±0.2%fullscale

Hysteresis2000 lb to 50000 lb

±0.15%fullscale

Hysteresis75000 lb to 20000 lb

±0.2%fullscale

Non-repeatability ±0.05%fullscale

Output 2mV/V

Operation Tension

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto121°C[-65°Fto250°F]

Temperature, compensated 15°Cto71°C[60°Fto160°F]

Temperature effect, zero 0.005%fullscale/°F

Temperature effect, span 0.005%fullscale/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded foil

Excitation(calibration) 10 Vdc

Excitation(acceptable) Upto15VdcorVac

Insulation resistance 5000 mOhm @ 50 Vdc

Bridge resistance (toler-ance)

350 ohm

Zero balance (tolerance) ±1%fullscale

Shuntcalibrationdata Included

Electricaltermination(std)2000 lb to 50000 lb

PTIH-10-6Porequivalent(hermeticstainless)

Electricaltermination(std)75000 lb to 200000 lb

MS3102E-14S-6Porequivalent

Mating connector (not in-cluded) 2000 lb to 50000 lb

PT06A-10-6Sorequivalent(AA111)

Mating connector (not included) 75000 lb to 200000 lb

MS3106A-14S-6Sorequivalent(AA121)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 150%FS1

Weight Seetable

Material Stainlesssteel

Deflection full scale Seetable

Naturalfrequency Seetable

RANGE CODES

Range Code

Available ranges Range Code

Available ranges

DL 2000 lb EL 20000 lb

DN 3000 lb EN 30000 lb

DP 4000 lb EP 50000 lb

DR 5000 lb ER 75000 lb

DT 75000 lb ET 100000 lb

DV 10000 lb FJ 150000 lb

EJ 15000 lb FL 200000 lb

WIRING CODES

Connector Unamplified (Std.)

A (+) excitation

B (+) excitation

C (-) excitation

D (-) excitation

E (-) output

F (+) output

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb) Deflection at full scale mm [in]

Ringing fre-quency (Hz)

Weight kg [lb]

2000 0,076[0.003] 5000 0,58[1.3]

3000 0,076[0.003] 5000 0,58[1.3]

4000 0,076[0.003] 5100 0,58[1.3]

5000 0,076[0.003] 5200 0,58[1.3]

7500 0,076[0.003] 8000 0,72[1.6]

10000 0,076[0.003] 8500 0,72[1.6]

15000 0,076[0.003] 9000 0,72[1.6]

20000 0,102[0.004] 9000 0,77[1.7]

30000 0,102[0.004] 8000 1,58[3.5]

50000 0,127[0.005] 8000 1,67[3.7]

75000 to 100000

0,152[0.006] 3500 18,00[39.7]

150000 to 200000

0,178[0.007] 3000 33,02[72.8]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Rod End In-Line Tension Load CellINTERNAL AMPLIFIERS

Amplifier specifica-tions

Voltage output: Option 2b

Voltage output: Option 2c

Voltage output: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Option 2n (2N)***

Output signal ±5 V 0 V to 5 V or ±5 V @ 45 mA

0 V to 10 V or ±10 V @ 45 mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage)

±15Vor26Vdcto32 Vdc

11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28 Vdc

Input power (current)

45 mA 40 mA 40 mA 65mA 4 mA to 28 mA 4 mA to 24 mA

Freq. resp (amp)

3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rej.

60db 60db 60db 60db 60db 60db

Operating temp.

-20 °F to 185 °F -20 °F to 185 °F -20 °F to 185 °F 0 °F to 185 °F 0 °F to 185 °F -20 °F to 185 °F

Reverse voltage protection

Yes Yes Yes Yes Yes Yes

Short cir. protection

Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)5

A(+)SupplyB Output commonCSupplyreturnD (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB No connectionCNoconnectionD (+) OutputECasegroundF No connection

A(+)SupplyB No connectionCNoconnectionD (+) OutputECasegroundF No connection

Wiring code: cable5,6,7

R(+)SupplyBl Output commonGSupplyreturnW (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl (+) OutputWCaseground

R(+)SupplyBl (+) OutputWCaseground

* Black and green wires are internally connected.**PinsBandCareinternallyconnected.***SeeourWebsiteforthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model RFOPTION CODES

Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 2K, 3K, 4K, 5K, 7.5K, 10K, 15K, 20K, 30K, 50K, 75K, 100K, 150K, 200K

Temperature compensa-tion

1a.60°Fto160°F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F 1f. 70 °F to 250 °F

1g. 70 °F to 325 °F8

1h. 70 °F to 400 °F8

1i.-65°Fto250°F8

1j.0°Cto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal amplifiers

2b. 4 wire, ±5 Vdc output2c. 0 Vdc to 5 Vdc2j. 4 mA to 20 mA (three-wire) output2k. 4 mA to 20 mA (two-wire)12

2n (2N) 4 mA to 20 mA (two-wire) intrinsically safe12

2t. 0 Vdc to 10 Vdc output2u.Unamplified,mV/Voutput

Internal amp enhance-ments

3a.Input/outputisolation7

3d. Remote buffered shunt calibration

Electrical termination

6a.BendixPTIH-10-6P(orequivalent)6-pin,(max.250°F)(ranges 50000 lb and below)

6b.MSconnectorMS3102E-14S-6P(mateswithMS3106E-14S-6),(max.160°F)(rangesabove50000lb)6

6e.Integralcable:Teflon6f.Integralcable:PVC

6g.Integralcable:Neoprene6h.Integralcable:Silicone6i.Integralunderwatercable6j.1/2-14conduitfittingwith5ftof4conductorPVCcable6q.Integralcable:Polyurethane6v.Phoenixconnectoronendofcable

Shunt calibration

8a. Precision internal resistor8

Bridge type 11a.Squarebridge8

11b.Symmetricalbridge8 11c.Squareandsymmetricalbridge8 31a. Dual bridge

Bridge resistance

12b. 5000 ohm (foil) (max. 250 °F)

Zero and span adjustment

14a. No access to zero and span adjustment

Electrical connector orientation

15a. Horizontal electrical exit port orientation15b. Vertical electrical exit port orientation15c. Radial electrical exit port orientation15d.Connectoronendofcable

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration8

53t.TEDSIEEE1451.4module9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl5

Rod End In-Line Tension Load Cell

MOUNTING DIMENSIONS

TYPICAL SYSTEM DIAGRAM

Unamplified only Amplified only

Order code(Unamp/Amp)

D mm [in] L1 mm [in] A mm [in] B mm [in] L2 mm [in] E mm [in] F mm [in]

AL414/AL614 38,1[1.50] 107,95[4.25] 19,05[0.75] 20,82[0.82] see below 49,53[1.95] 38,1[1.50]

AL416/AL616 44,45[1.75] 127[5.00] 19,05[0.75] 20,82[0.82] see below 49,53[1.95] 38,1[1.50]

AL418/AL618 63,5[2.50] 177,8[7.00] 19,05[0.75] 20,82[0.82] see below 49,53[1.95] 38,1[1.50]

THREAD SIZES AND OPTION CODES

13a 13b 13c 13d 13e

Range (lb) 1/2-20 UNF

3/4-16 UNF

7/8-14 UNF

1-14 UNF

1 1/2-12 UNF

2000 to 5000 AL414 AL414 – – –

7500 to 15000

– AL416 AL416 AL416 AL418

20000 – – AL416 AL416 AL418

30000 to 50000

– – – – AL418

L2mm[in] 19,05 [0.75]

24,13 [0.95]

24,13 [0.95]

25,4 [1.0]

38,1 [1.50]

NON-STANDARD RANGES - ORDER CODE AL412

Range (lb) Thread type

D mm [in] L1 mm [in]

L2 mm [in]

75000 to 100000

21/2-12UNF

114,3[4.50] 342,9 [13.50]

88,9[3.50]

150000 to 200000

31/2-8UNF 139,7[5.50] 457,2 [18.00]

114,3[4.50]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

008656-2-EN IL50 GLO January 2010Copyright © 2010 Honeywell International Inc. All rights reserved.

Model RF Rod End In-Line Tension Load Cell

Sensing and Control

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422

www.honeywell.com

NOTES

1. Allowable maximum loads – maximum load to be applied without damage.2

2. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides50%(unamplifiedunits),75%(4mAto20mAthree-wireunits)or80%(voltageamplifiedunits)offullscaleoutputforquickcalibration.Shuntcalibrationcomesstandardwithinternalampli-fier option 2a, 2b, 2c, 2t and 2j.

4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White;G=Green.Colorspecifyingcableandnumberorletterspecifying connector.

5. No mating connector necessary for cable option.6. Cannotbeusedwithoptions1c,1e,1f,1g,1h,or1i.7. Only available with option 2b or 2c.8. Not available with amplified option.9. ConsultfactoryforTEDSavailabilitywithamplifiedmodels.10. Termination dependent; consult factory.11. This unit calibrated to Imperial (non-Metric) units.12. 5000ohmbridgerequired.

Find out more

Honeywell serves its customers

through a worldwide network of

sales offices, representatives

and distributors. For application

assistance, current specifica-

tions, pricing or name of the

nearest Authorized Distributor,

contact your local sales office.

To learn more about Honeywell’s

test and measurement products,

call +1-614-850-5000, visit

www.honeywell.com/sensotec,

ore-mailinquiriesto

[email protected]

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthisdatasheetisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.

•Completeinstallation,operationandmaintenanceinformation is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Rod End In-line Tension Load CellModel RH

DESCRIPTIONModel RH, with male and female threads, is a high output rod

end load cell designed to be mounted inline to the load axis to

measure tension. The outputs for these load cells are ±5 Vdc or

10 Vdc, or 4 mA to 20 mA (two wire) all calibrated in tension. The

mounting thread configurations and the all welded stainless steel

construction make these tension load cells ideal for a variety of

rugged field applications as well as in the laboratory.

The optional high output signal offers resistance to electrical

noise as well as additional signal resolution. Additional options

include an internal buffered shunt calibration circuit for ease of

setup with an associated indicator, and a variety of thread selec-

tions, including metric sizes.

FEATURES• 2000lbto200000lbrange

• Male/femalethreads

• Stainlesssteel,all-weldedconstruction

• 0Vdcto5Vdcor4mAto20mAoutputs

• Upto0.15%linearity

• CEapproved10

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model RHPERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges12 2000 lb to 200000 lb

Linearity100 lb to 1000 lb

±0.2%fullscale

Linearity2000 lb to 50000 lb

±0.15%fullscale

Linearity75000 lb to 20000 lb

±0.2%fullscale

Hysteresis100 lb to 1000 lb

±0.2%fullscale

Hysteresis2000 lb to 50000 lb

±0.15%fullscale

Hysteresis75000 lb to 20000 lb

±0.2%fullscale

Non-repeatability ±0.05%fullscale

Output 2mV/V

Operation Tension

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto121°C[-65°Fto250°F]

Temperature, compensated 15°Cto71°C[60°Fto160°F]

Temperature effect, zero 0.005%fullscale/°F

Temperature effect, span 0.005%fullscale/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded foil

Excitation(calibration) 10 Vdc

Excitation(acceptable) Upto15VdcorVac

Insulation resistance 5000 mOhm @ 50 Vdc

Bridge resistance (toler-ance)

350 ohm

Zero balance (tolerance) ±1%fullscale

Shuntcalibrationdata Included

Electricaltermination(std)2000 lb to 50000 lb

PTIH-10-6Porequivalent(hermeticstainless)

Electricaltermination(std)75000 lb to 200000 lb

MS3102E-14S-6Porequivalent

Mating connector (not in-cluded) 2000 lb to 50000 lb

PT06A-10-6Sorequivalent(AA111)

Mating connector (not included) 75000 lb to 200000 lb

MS3106A-14S-6Sorequivalent(AA121)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 150%FS1

Weight Seetable

Material Stainlesssteel

Deflection full scale Seetable

Naturalfrequency Seetable

RANGE CODES

Range Code

Available ranges Range Code

Available ranges

DL 2000 lb EL 20000 lb

DN 3000 lb EN 30000 lb

DP 4000 lb EP 50000 lb

DR 5000 lb ER 75000 lb

DT 75000 lb ET 100000 lb

DV 10000 lb FJ 150000 lb

EJ 15000 lb FL 200000 lb

WIRING CODES

Connector Unamplified (Std.)

A (+) excitation

B (+) excitation

C (-) excitation

D (-) excitation

E (-) output

F (+) output

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb) Deflection at full scale mm [in]

Ringing fre-quency (Hz)

Weight kg [lb]

2000 0,076[0.003] 5000 0,49[1.1]

3000 0,076[0.003] 5000 0,49[1.1]

4000 0,076[0.003] 5100 0,49[1.1]

5000 0,076[0.003] 5200 0,49[1.1]

7500 0,102[0.004] 7500 0,81[1.8]

10000 0,102[0.004] 7600 0,81[1.8]

15000 0,127[0.005] 8000 0,81[1.8]

20000 0,127[0.005] 9800 0,81[1.8]

30000 0,127[0.005] 8000 1,99[4.4]

50000 0,127[0.005] 8200 1,99[4.4]

75000 to 100000

0,152[0.006] 5000 16,01[35.3]

150000 to 200000

0,178[0.007] 4200 18,00[39.7]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Rod End In-Line Tension Load CellINTERNAL AMPLIFIERS

Amplifier specifica-tions

Voltage output: Option 2b

Voltage output: Option 2c

Voltage output: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Option 2n (2N)***

Output signal ±5 V 0 V to 5 V or ±5 V @ 45 mA

0 V to 10 V or ±10 V @ 45 mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage)

±15Vor26Vdcto32 Vdc

11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28 Vdc

Input power (current)

45 mA 40 mA 40 mA 65mA 4 mA to 28 mA 4 mA to 24 mA

Freq. resp (amp)

3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rej.

60db 60db 60db 60db 60db 60db

Operating temp.

-20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F

Reverse voltage protection

Yes Yes Yes Yes Yes Yes

Short cir. protection

Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)5

A(+)SupplyB Output commonCSupplyreturnD (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB No connectionCNoconnectionD (+) OutputECasegroundFNoconnection

A(+)SupplyB No connectionCNoconnectionD (+) OutputECasegroundFNoconnection

Wiring code: cable5,6,7

R(+)SupplyBl Output commonGSupplyreturnW (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl (+) OutputWCaseground

R(+)SupplyBl (+) OutputWCaseground

* Black and green wires are internally connected.**PinsBandCareinternallyconnected.***SeeourWebsiteforthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model RHOPTION CODES

Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 2K, 3K, 4K, 5K, 7.5K, 10K, 15K, 20K, 30K, 50K, 75K, 100K, 150K, 200K

Temperature compensa-tion

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F

1g.70°Fto325°F8

1h.70°Fto400°F8

1i.-65°Fto250°F8

1j.0°Cto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal amplifiers

2u.Unamplified,mV/Voutput2b. 4 wire, ±5 Vdc output2c. 0 Vdc to 5 Vdc2j. 4 mA to 20 mA (three-wire) output

2k. 4 mA to 20 mA (two-wire)12

2n (2N) 4 mA to 20 mA (two-wire) intrinsically safe12

2t. 0 Vdc to 10 Vdc output

Internal amp enhance-ments

3a.Input/outputisolation7

3d. Remote buffered shunt calibration

Electrical termination

6a.BendixPTIH-10-6P(orequivalent)6-pin,(max.250°F)(ranges 50000 lb and below)

6b.MSconnectorMS3102E-14S-6P(mateswithMS3106E-14S-6),(max.160°F)(rangesabove50000lb)6

6e.Integralcable:Teflon6f.Integralcable:PVC

6g.Integralcable:Neoprene6h.Integralcable:Silicone6i.Integralunderwatercable6j.1/2-14conduitfittingwith5ftof4conductorPVCcable6q.Integralcable:Polyurethane6v.Phoenixconnectoronendofcable

Shunt calibration

8a. Precision internal resistor8

Bridge type 11a.Squarebridge8

11b.Symmetricalbridge8 11c.Squareandsymmetricalbridge8 31a. Dual bridge

Bridge resistance

12b.5000ohm(foil)(max.250°F)

Zero and span adjustment

14a. No access to zero and span adjustment

Electrical connector orientation

15a. Horizontal electrical exit port orientation15b. Vertical electrical exit port orientation15c. Radial electrical exit port orientation15d.Connectoronendofcable

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration8

53t.TEDSIEEE1451.4module9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl5

Rod End In-Line Tension Load Cell

MOUNTING DIMENSIONS

TYPICAL SYSTEM DIAGRAM

Unamplified only Amplified only

Order code(Unamp/Amp)

D mm [in] L1 mm [in] A mm [in] B mm [in] L2 mm [in] E mm [in] F mm [in]

AL419/AL619 38,1[1.50] 107,95[4.25] 19,05[0.75] 20,82[0.82] see below 49,53[1.95] 38,1[1.50]

AL420/AL620 44,45[1.75] 127[5.00] 19,05[0.75] 20,82[0.82] see below 49,53[1.95] 38,1[1.50]

AL424/AL624 63,5[2.50] 177,8[7.00] 19,05[0.75] 20,82[0.82] see below 49,53[1.95] 38,1[1.50]

THREAD SIZES AND OPTION CODES

13a 13b 13c 13d 13e

Range (lb) 1/2-20 UNF

3/4-16 UNF

7/8-14 UNF

1-14 UNF

1 1/2-12 UNF

2000 to 5000 AL419/AL619

AL419/AL619

– – –

7500 to 15000

– AL420/AL620

AL420/AL620

AL420/AL620

AL424/AL624

20000 – – AL420/AL620

AL420/AL620

AL424/AL624

30000 to 50000

– – – – AL424/AL624

L2mm[in] 19,05 [0.75]

24,13 [0.95]

24,13 [0.95]

25,4 [1.0]

38,1 [1.50]

NON-STANDARD RANGES - ORDER CODE AL425

Range (lb) Thread type

D mm [in] L1 mm [in]

L2 mm [in]

75000 to 100000

21/2-12UNF

114,3[4.50] 342,9 [13.50]

88,9[3.50]

150000 to 200000

31/2-8UNF 139,7[5.50] 457,2 [18.00]

114,3[4.50]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

008655-2-EN IL50 GLO January 2010Copyright © 2010 Honeywell International Inc. All rights reserved.

Model RH Rod End In-Line Tension Load Cell

Sensing and Control

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422

www.honeywell.com

NOTES

1. Allowable maximum loads – maximum load to be applied without damage.2

2. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides50%(unamplifiedunits),75%(4mAto20mAthree-wireunits)or80%(voltageamplifiedunits)offullscaleoutputforquickcalibration.Shuntcalibrationcomesstandardwithinternalampli-fier option 2a, 2b, 2c, 2t and 2j.

4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White;G=Green.Colorspecifyingcableandnumberorletterspecifying connector.

5. No mating connector necessary for cable option.6. Cannotbeusedwithoptions1c,1e,1f,1g,1h,or1i.7. Only available with option 2b or 2c.8. Not available with amplified option.9. ConsultfactoryforTEDSavailabilitywithamplifiedmodels.10. Range dependent; consult factory. Termination dependent; consult

factory.11. Internal amp and termination dependent; consult factory.12. This unit calibrated to Imperial (non-Metric) units.13. 5000ohmbridgerequired.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthisdatasheetisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.

•Completeinstallation,operationandmaintenanceinformation is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

Find out more

Honeywell serves its customers

through a worldwide network of

sales offices, representatives

anddistributors.Forapplication

assistance, current specifica-

tions, pricing or name of the

nearest Authorized Distributor,

contact your local sales office.

To learn more about Honeywell’s

test and measurement products,

call +1-614-850-5000, visit

www.honeywell.com/sensotec,

ore-mailinquiriesto

[email protected]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Rod End In-line Tension Load CellModel RM

DESCRIPTIONModel RM, with male threads, is a high output rod end load cell

designed to be mounted inline to the load axis to measure ten-

sion. The outputs for these load cells are ±5 Vdc or 10 Vdc, or

4 mA to 20 mA (two wire) all calibrated in tension. The mount-

ing thread configurations and the all welded stainless steel

construction make these tension load cells ideal for a variety of

rugged field applications as well as in the laboratory.

The optional high output signal offers resistance to electrical

noise as well as additional signal resolution. Additional options

include an internal buffered shunt calibration circuit for ease of

setup with an associated indicator, and a variety of thread selec-

tions, including metric sizes.

FEATURES• 2000lbto200000lbrange

• Male/malethreads

• Stainlesssteel,all-weldedconstruction

• 0Vdcto5Vdcor4mAto20mAoutputs

• Upto0.15%linearity

• CEapproved10

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model RMPERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges11 2000 lb to 200000 lb1

Linearity100 lb to 1000 lb

±0.2%fullscale

Linearity2000 lb to 50000 lb

±0.15%fullscale

Linearity75000 lb to 20000 lb

±0.2%fullscale

Hysteresis100 lb to 1000 lb

±0.2%fullscale

Hysteresis2000 lb to 50000 lb

±0.15%fullscale

Hysteresis75000 lb to 20000 lb

±0.2%fullscale

Non-repeatability ±0.05%fullscale

Output (tolerance) 2mV/V

Operation Tension

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto121°C[-65°Fto250°F]

Temperature, compensated 15°Cto71°C[60°Fto160°F]

Temperature effect, zero 0.005%fullscale/°F

Temperature effect, span 0.005%fullscale/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded foil

Excitation(calibration) 10 Vdc

Excitation(acceptable) Upto15VdcorVac

Insulation resistance 5000 mOhm @ 50 Vdc

Bridge resistance (toler-ance)

350 ohm

Zero balance (tolerance) ±1%fullscale

Shuntcalibrationdata Included

Electricaltermination(std)2000 lb to 50000 lb

PTIH-10-6Porequivalent(hermeticstainless)

Electricaltermination(std)75000 lb to 200000 lb

MS3102E-14S-6Porequivalent

Mating connector (not in-cluded) 2000 lb to 50000 lb

PT06A-10-6Sorequivalent(AA111)

Mating connector (not included) 75000 lb to 200000 lb

MS3106A-14S-6Sorequivalent(AA121)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 150%FS1

Weight Seetable

Material Stainlesssteel

Deflection full scale Seetable

Naturalfrequency Seetable

RANGE CODES

Range Code

Available ranges Range Code

Available ranges

DL 2000 lb EL 20000 lb

DN 3000 lb EN 30000 lb

DP 4000 lb EP 50000 lb

DR 5000 lb ER 75000 lb

DT 75000 lb ET 100000 lb

DV 10000 lb FJ 150000 lb

EJ 15000 lb FL 200000 lb

WIRING CODES

Connector Unamplified (Std.)

A (+) excitation

B (+) excitation

C (-) excitation

D (-) excitation

E (-) output

F (+) output

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb) Deflection at full scale mm [in]

Ringing fre-quency (Hz)

Weight kg [lb]

2000 0,076[0.003] 5000 0,45[1.0]

3000 0,076[0.003] 5000 0,45[1.0]

4000 0,076[0.003] 5100 0,45[1.0]

5000 0,076[0.003] 5200 0,45[1.0]

7500 0,102[0.004] 7500 0,68[1.5]

10000 0,102[0.004] 7600 0,68[1.5]

15000 0,127[0.005] 8000 0,68[1.5]

20000 0,127[0.005] 9800 0,68[1.5]

30000 0,127[0.005] 8000 1,90[4.2]

50000 0,127[0.005] 8200 1,90[4.2]

75000 to 100000

0,152[0.006] 5000 7,34[16.5]

150000 to 200000

0,178[0.007] 4200 16,01[35.3]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Rod End In-Line Tension Load CellINTERNAL AMPLIFIERS

Amplifier specifica-tions

Voltage output: Option 2b

Voltage output: Option 2c

Voltage output: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Option 2n (2N)***

Output signal ±5 V 0 V to 5 V or ±5 V @ 45 mA

0 V to 10 V or ±10 V @ 45 mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage)

±15Vor26Vdcto32 Vdc

18Vdcto28Vdc 15Vdcto28Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28Vdc

Input power (current)

45 mA 40 mA 40 mA 65mA 4mAto28mA 4 mA to 24 mA

Freq. resp (amp)

3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power supply rej.

60db 60db 60db 60db 60db 60db

Operating temp.

-20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F

Reverse volt-age protec-tion

Yes Yes Yes Yes Yes Yes

Short cir. protection

Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)5

A(+)SupplyB Output commonCSupplyreturnD (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB No connectionCNoconnectionD (+) OutputECasegroundFNoconnection

A(+)SupplyB No connectionCNoconnectionD (+) OutputECasegroundFNoconnection

Wiring code: cable5,6,7

R(+)SupplyBl Output commonGSupplyreturnW (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl (+) OutputWCaseground

R(+)SupplyBl (+) OutputWCaseground

* Black and green wires are internally connected.**PinsBandCareinternallyconnected.***SeeourWebsiteforthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model RMOPTION CODES

Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 2K, 3K, 4K, 5K, 7.5K, 10K, 15K, 20K, 30K, 50K, 75K, 100K, 150K, 200K

Temperature compensa-tion

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F

1g.70°Fto325°F8

1h.70°Fto400°F8

1i.-65°Fto250°F8

1j.0°Cto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal amplifiers

2u.Unamplified,mV/Voutput2b. 4 wire, ±5 Vdc output2c. 0 Vdc to 5 Vdc2j. 4 mA to 20 mA (three-wire) output

2k. 4 mA to 20 mA (two-wire)12

2n (2N) 4 mA to 20 mA (two-wire) intrinsically safe12

2t. 0 Vdc to 10 Vdc output

Internal amp enhance-ments

3a.Input/outputisolation7

3d. Remote buffered shunt calibration

Electrical termination

6a.BendixPTIH-10-6P(orequivalent)6-pin,(max.250°F)(ranges 50000 lb and below)

6b.MSconnectorMS3102E-14S-6P(mateswithMS3106E-14S-6),(max.160°F)(rangesabove50000lb)6

6e.Integralcable:Teflon6f.Integralcable:PVC

6g.Integralcable:Neoprene6h.Integralcable:Silicone6i.Integralunderwatercable6j.1/2-14conduitfittingwith5ftof4conductorPVCcable6q.Integralcable:Polyurethane6v.Phoenixconnectoronendofcable

Shunt calibration

8a.Precisioninternalresistor8

Bridge type 11a.Squarebridge8

11b.Symmetricalbridge8 11c.Squareandsymmetricalbridge8 31a. Dual bridge

Bridge resistance

12b.5000ohm(foil)(max.250°F)

Zero and span adjustment

14a. No access to zero and span adjustment

Electrical connector orientation

15a. Horizontal electrical exit port orientation15b. Vertical electrical exit port orientation15c. Radial electrical exit port orientation15d.Connectoronendofcable

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration8

53t.TEDSIEEE1451.4module9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl5

Rod End In-Line Tension Load Cell

MOUNTING DIMENSIONS

TYPICAL SYSTEM DIAGRAM

Unamplified only Amplified only

Order code(Unamp/Amp)

D mm [in] L1 mm [in] A mm [in] B mm [in] L2 mm [in] E mm [in] F mm [in]

AL413/AL613 38,1[1.50] 66,4[2.60] 19,05[0.75] 20,82[0.82] see below 49,53[1.95] 38,1[1.50]

AL415/AL615 44,45[1.75] 66,4[2.60] 19,05[0.75] 20,82[0.82] see below 49,53[1.95] 38,1[1.50]

AL417/AL617 63,5[2.50] 77,47[3.05] 19,05[0.75] 20,82[0.82] see below 49,53[1.95] 38,1[1.50]

THREAD SIZES AND OPTION CODES

13a 13b 13c 13d 13e

Range (lb) 1/2-20 UNF

3/4-16 UNF

7/8-14 UNF

1-14 UNF

1 1/2-12 UNF

2000 to 5000 AL413 AL413 AL413

7500 to 15000

AL415 AL415 AL415 AL417

20000 AL415 AL415 AL417

30000 to 50000

AL417

L2mm[in] 24,13 [0.95]

24,13 [0.95]

24,13 [0.95]

31,75 [1.25]

38,1[1.50]

NON-STANDARD RANGES - ORDER CODE AL411

Range (lb) Thread type

D mm [in] L1 mm [in]

L2 mm [in]

75000 to 100000

21/2-12UNF

88,9[3.50] 101,6[4.00] 76,2[3.00]

150000 to 200000

31/2-8UNF 114,3[4.50] 127[5.00] 101,6[4.00]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

008654-2-EN IL50 GLO January 2010Copyright © 2010 Honeywell International Inc. All rights reserved.

Model RM Rod End In-Line Tension Load Cell

Sensing and Control

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422

www.honeywell.com

NOTES

1. Allowable maximum loads – maximum load to be applied without damage.2

2. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

3. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides50%(unamplifiedunits),75%(4mAto20mAthree-wireunits)or80%(voltageamplifiedunits)offullscaleoutputforquickcalibration.Shuntcalibrationcomesstandardwithinternalampli-fier option 2a, 2b, 2c, 2t and 2j.

4. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White;G=Green.Colorspecifyingcableandnumberorletterspecifying connector.

5. No mating connector necessary for cable option.6. Cannotusewithoptions1c,1e,1f,1g,1h,or1i.7. Only available with option 2b or 2c.8. Notavailablewithamplifiedoption.9. ConsultfactoryforTEDSavailabilitywithamplifiedmodels.10. Termination dependent; consult factory.11. This unit calibrated to Imperial (non-Metric) units.12. 5000ohmbridgerequired.

Find out more

Honeywell serves its customers

through a worldwide network of

sales offices, representatives

anddistributors.Forapplication

assistance, current specifica-

tions, pricing or name of the

nearest Authorized Distributor,

contact your local sales office.

To learn more about Honeywell’s

test and measurement products,

call +1-614-850-5000, visit

www.honeywell.com/sensotec,

ore-mailinquiriesto

[email protected]

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystop devices or in any other application where failure of the product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthisdatasheetisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.

•Completeinstallation,operationandmaintenanceinformation is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Rod End In-line Compression/Tension Load CellModel RGF

FEATURES• 2000lbto50000lbrange

• Female/femalethreads

• Stainlesssteel,all-weldedconstruction

• 1mV/Vnominal(standard);0Vdcto5Vdcor4mAto20

mAoutputs(optional)

• Compression/tension

• 0.25%accuracy

• CEapproved10

DESCRIPTIONTheModelRGFIn-Lineloadcellsarehighquality,stainlesssteel

ruggedloadcellscapableofwithstandingsignificantoff-axis

loads,makingthemanidealchoiceforin-linecompressionmea-

surementortensionmeasurementwheresideloadingcannotbe

completelycontrolled.Theflexiblemountingoptionsmakeappli-

cationseasiertoimplement,andtheallstainlesssteel,hermetic

constructioniswellsuitedtocorrosiveandveryhighhumidity

environments.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model RGFPERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadranges11 2000,3000,5000,10000,15000,25000,50000lb

Accuracy ±0.25%fullscale1

Linearity ±0.25%fullscale

Hysteresis ±0.25%fullscale

Non-repeatability ±0.05%fullscale

Output(tolerance) 1mV/V(nominal)

Operation Tension/compression

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature,operating -54°Cto121°C[-65°Fto250°F]

Temperature,compensated 15°Cto71°C[60°Fto160°F]

Temperatureeffect,zero 0.005%fullscale/°F

Temperatureeffect,span 0.005%fullscale/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bondedfoil

Excitation(calibration) 10Vdc

Excitation(acceptable) Upto15VdcorVac

Insulationresistance 5000mOhm@50Vdc

Bridgeresistance(toler-ance)

700ohm

Shuntcalibrationdata Included

Electricaltermination(std) PTIH-10-6Porequivalent(hermeticstainless)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximumallowableload 150%FS1

Casematerial Stainlesssteel

Lifecycles(approx) >10millioncycles

Deflectionfullscale 0,076mm[0.003in]

RANGE CODES

Range Code Available ranges

DL 2000lb

DN 3000lb

DR 5000lb

DV 10000lb

EJ 15000lb

EM 25000lb

EP 50000lb

WIRING CODES

Connector Unamplified (Std.)

A (+)excitation

B (+)excitation

C (-)excitation

D (-)excitation

E (-)output

F (+)output

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb) Deflection at full scale mm [in]

Ringing fre-quency (Hz)

Weight kg [lb]

2000 0,025[0.001] 10000 0,55[1.2]

3000 0,025[0.001] 12000 0,55[1.2]

5000 0,050[0.002] 15000 0,63[1.4]

10000 0,050[0.002] 10000 1,3[2.9]

15000 0,050[0.002] 10000 1,3[2.9]

25000 0,050[0.002] 6500 4,3[9.5]

50000 0,076[0.003] 7000 4,49[9.9]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Rod End In-Line Compression/Tension Load CellINTERNAL AMPLIFIERS

Amplifier specifica-tions

Voltage output: Option 2b

Voltage output: Option 2c

Voltage output: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Option 2n (2N)***

Output signal ±5V 0Vto5Vor±5V@45mA

0Vto10Vor±10V@45mA

4mAto20mA 4mAto20mA 4mAto20mA

Input power (voltage)

±15Vor26Vdcto32Vdc

11Vdcto28Vdc 15Vdcto28Vdc 22Vdcto32Vdc 15Vdcto40Vdc 9Vdcto28Vdc

Input power (current)

45mA 40mA 40mA 65mA 4mAto28mA 4mAto24mA

Freq. resp (amp)

3000Hz 3000Hz 3000Hz 2500Hz 300Hz 2000Hz

Power supply rej.

60db 60db 60db 60db 60db 60db

Operating temp.

-20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F

Reverse volt-age protec-tion

Yes Yes Yes Yes Yes Yes

Short cir. protection

Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)4

A(+)SupplyBOutputcommonCSupplyreturnD(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBOutputcommon**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBOutputcommon**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBOutputcommon**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

Wiring code: cable4,5,6

R(+)SupplyBlOutputcommonGSupplyreturnW(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBlOutputcommon*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBlOutputcommon*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBlOutputcommon*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl(+)OutputWCaseground

R(+)SupplyBl(+)OutputWCaseground

*Blackandgreenwiresareinternallyconnected.**PinsBandCareinternallyconnected.***SeeourWebsiteforthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.

ALLOWABLE MAXIMUM LOADS2

Capacity (lb) Side load (lb) (% of load capac-ity)

Torque (lb-in)(% of load capac-ity)

2000 20% 20%

3000 20% 20%

5000 20% 20%

10000 20% 20%

15000 20% 20%

25000 20% 20%

50000 20% 20%

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model RGFOPTION CODES

Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 2K,3K,5K,10K,15K,25K,50Klb

Temperature compensa-tion

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F

1g.70°Fto325°F8

1h.70°Fto400°F8

1i.-65°Fto250°F8

1j.0°Cto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal amplifiers

2u.Unamplified,mV/Voutput2b.4wire,±5Vdcoutput2c.0Vdcto5Vdc

2j.4mAto20mA(three-wire)output2k.4mAto20mA(two-wire)13

2t.0Vdcto10Vdcoutput

Internal amp enhance-ments

3a.Input/outputisolation7

3d.Remotebufferedshuntcalibration

Electrical termination

6a.BendixPTIH-10-6P(orequivalent)6-pin,(max.250°F)(ranges50000lbandbelow)

6b.MSconnectorMS3102E-14S-6P(mateswithMS3106E-14S-6),(max.160°F)(rangesabove50000lb)6

6e.Integralcable:Teflon6f.Integralcable:PVC

6g.Integralcable:Neoprene6h.Integralcable:Silicone6i.Integralunderwatercable6j.1/2-14conduitfittingwith5ftof4conductorPVCcable6q.Integralcable:Polyurethane6v.Phoenixconnectoronendofcable

Shunt calibration

8a.Precisioninternalresistor8

Bridge type 11a.Squarebridge8

11b.Symmetricalbridge811c.Squareandsymmetricalbridge831a.Dualbridge

Bridge resistance

12b.5000ohm(foil)(max.250°F)

Zero and span adjustment

14a.Noaccesstozeroandspanadjustment

Electrical connector orientation

15a.Horizontalelectricalexitportorientation15b.Verticalelectricalexitportorientation15c.Radialelectricalexitportorientation15d.Connectoronendofcable

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration8

53t.TEDSIEEE1451.4module9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl5

Rod End In-Line Compression/Tension Load CellMOUNTING DIMENSIONS

TYPICAL SYSTEM DIAGRAM

Unamplified only Amplified only

Range (lb) D mm [in] T L2 mm [in] L1 mm [in] A mm [in] B mm [in] E mm [in] F mm [in]

2000to5000 44,45[1.75] 3/4-16UNF 24,13[0.95] 90,42[3.56] 19,05[0.75] 20,82[0.82] 49,53[1.95] 38,1[1.50]

10000to15000 63,5[2.50] 11/2-12UNF 44,45[1.75] 155,54[6.12] 19,05[0.75] 20,82[0.82] 49,53[1.95] 38,1[1.50]

25000to50000 88,9[3.50] 2-12UNF 57,15[2.25] 203,2[8.00] 19,05[0.75] 20,82[0.82] 49,53[1.95] 38,1[1.50]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

008659-2-EN IL50 GLO January 2010Copyright © 2010 Honeywell International Inc. All rights reserved.

Model RGF Rod End In-Line Compression/Tension Load Cell

Sensing and Control

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422

www.honeywell.com

NOTES

1. Allowablemaximumloads–maximumloadtobeappliedwithoutdamage.2

2. Withoutdamage-loadingtothislevelwillnotcauseexcessivezeroshiftorperformancedegradation.Theusermustconsiderfatiguelifeforlongtermuseandstructuralintegrity.Allstructurallycriticalapplications(overheadloading,etc.)shouldalwaysbedesignedwithsafetyredundantloadpaths.

3. Interconnectingshuntcal.1terminalwithshuntcal.2terminalprovides50%(unamplifiedunits),75%(4mAto20mAthree-wireunits)or80%(voltageamplifiedunits)offullscaleoutputforquickcalibration.Shuntcalibrationcomesstandardwithinternalampli-fieroption2a,2b,2c,2tand2j.

4. O=Orange;Y=Yellow;B=Blue;Bl=Black;R=Red;Br=Brown;W=White;G=Green.Colorspecifyingcableandnumberorletterspecifyingconnector.

5. Nomatingconnectornecessaryforcableoption.6. Cannotbeusedwithoptions1c,1e,1f,1g,1h,or1i.7. Onlyavailablewithoption2bor2c.8. Notavailablewithamplifiedoption.9. ConsultfactoryforTEDSavailabilitywithamplifiedmodels.10. Terminationdependent;consultfactory.11. ThisunitcalibratedtoImperial(non-Metric)units.12. 5000ohmbridgerequired.

Find out more

Honeywellservesitscustomers

throughaworldwidenetworkof

salesoffices,representatives

anddistributors.Forapplication

assistance,currentspecifica-

tions,pricingornameofthe

nearestAuthorizedDistributor,

contactyourlocalsalesoffice.

TolearnmoreaboutHoneywell’s

testandmeasurementproducts,

call+1-614-850-5000,visit

www.honeywell.com/sensotec,

ore-mailinquiriesto

[email protected]

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthisdatasheetisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.

•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Rod End In-line Compression/Tension Load CellModel RGH

DESCRIPTIONThe Model RGH In-Line load cells are high quality, stainless

steel, rugged load cells capable of withstanding significant

off-axis loads, making them an ideal choice for in-line compres-

sion measurement or tension measurement where side loading

cannot be completely controlled. The flexible mounting options

make applications easier to implement, and the all stainless

steel, hermetic construction is well suited to corrosive and very

high humidity environments.

FEATURES• 2000lbto50000lbrange

• Male/femalethreads

• Stainlesssteel,all-weldedconstruction

• 1mV/Vnominal(standard);0Vdcto5Vdcor4mAto20

mAoutputs(optional)

• Compression/tension

• 0.25%accuracy

• CEapproved10

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model RGHPERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges11 2000,3000,4000,5000,10000,15000,25000,50000lb

Accuracy ±0.25%fullscale1

Linearity ±0.25%fullscale

Hysteresis ±0.25%fullscale

Non-repeatability ±0.05%fullscale

Output(tolerance) 1mV/V(nominal)

Operation Tension/compression

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto121°C[-65°Fto250°F]

Temperature, compensated 15°Cto71°C[60°Fto160°F]

Temperature effect, zero 0.005%fullscale/°F

Temperature effect, span 0.005%fullscale/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded foil

Excitation(calibration) 10Vdc

Excitation(acceptable) Upto15VdcorVac

Insulation resistance 5000mOhm@50Vdc

Bridgeresistance(toler-ance)

700ohm

Shuntcalibrationdata Included

Electricaltermination(std) PTIH-10-6Porequivalent(hermeticstainless)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 150%FS1

Casematerial Stainlesssteel

Lifecycles(approx) >10millioncycles

Deflection full scale 0,076mm[0.003in]

RANGE CODES

Range Code Available ranges

DL 2000lb

DN 3000lb

DP 4000lb

DR 5000lb

DV 10000lb

EJ 15000lb

EM 25000lb

EP 50000lb

WIRING CODES

Connector Unamplified (Std.)

A (+)excitation

B (+)excitation

C (-)excitation

D (-)excitation

E (-)output

F (+)output

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb) Deflection at full scale mm [in]

Ringing fre-quency (Hz)

Weight kg [lb]

2000 0,025[0.001] 10000 0,55[1.2]

3000 0,025[0.001] 12000 0,55[1.2]

4000 0.038[0.0015] 13000 0,59[1.3]

5000 0,050[0.002] 15000 0,63[1.4]

10000 0,050[0.002] 10000 1,3[2.9]

15000 0,050[0.002] 10000 1,3[2.9]

25000 0,050[0.002] 6500 4,3[9.5]

50000 0,076[0.003] 7000 4,3[9.5]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Rod End In-Line Compression/Tension Load CellINTERNAL AMPLIFIERS

Amplifier specifica-tions

Voltage output: Option 2b

Voltage output: Option 2c

Voltage output: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Option 2n (2N)***

Output signal ±5V 0Vto5Vor±5V@45mA

0Vto10Vor±10V@45mA

4mAto20mA 4mAto20mA 4mAto20mA

Input power (voltage)

±15Vor26Vdcto32Vdc

11Vdcto28Vdc 15Vdcto28Vdc 22Vdcto32Vdc 15Vdcto40Vdc 9Vdcto 28Vdc

Input power (current)

45mA 40mA 40mA 65mA 4mAto28mA 4mAto24mA

Freq. resp (amp)

3000Hz 3000Hz 3000Hz 2500Hz 300Hz 2000Hz

Power supply rej.

60db 60db 60db 60db 60db 60db

Operating temp.

-20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F

Reverse volt-age protec-tion

Yes Yes Yes Yes Yes Yes

Short cir. protection

Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)4

A(+)SupplyB Output commonCSupplyreturnD(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB No connectionCNoconnectionD(+)OutputECasegroundFNoconnection

A(+)SupplyB No connectionCNoconnectionD(+)OutputECasegroundFNoconnection

Wiring code: cable4,5,6

R(+)SupplyBl Output commonGSupplyreturnW(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl(+)OutputWCaseground

R(+)SupplyBl(+)OutputWCaseground

* Black and green wires are internally connected.**PinsBandCareinternallyconnected.***SeeourWebsiteforthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.

ALLOWABLE MAXIMUM LOADS2

Capacity (lb) Side load (lb) (% of load capac-ity)

Torque (lb-in)(% of load capac-ity)

2000 20% 20%

3000 20% 20%

4000 20% 20%

5000 20% 20%

10000 20% 20%

15000 20% 20%

25000 20% 20%

50000 20% 20%

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model RGHOPTION CODES

Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 2K,3K,4K,5K,10K,15K,25K,50Klb

Temperature compensa-tion

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F

1g.70°Fto325°F8

1h.70°Fto400°F8

1i.-65°Fto250°F8

1j.0°Cto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal amplifiers

2u.Unamplified,mV/Voutput2b.4wire,±5Vdcoutput2c.0Vdcto5Vdc

2j.4mAto20mA(three-wire)output2k.4mAto20mA(two-wire)13

2t.0Vdcto10Vdcoutput

Internal amp enhance-ments

3a.Input/outputisolation7

3d.Remotebufferedshuntcalibration

Electrical termination

6a.BendixPTIH-10-6P(orequivalent)6-pin,(max.250°F)(ranges50000lbandbelow)

6b.MSconnectorMS3102E-14S-6P(mateswithMS3106E-14S-6),(max.160°F)(rangesabove50000lb)6

6e.Integralcable:Teflon6f.Integralcable:PVC

6g.Integralcable:Neoprene6h.Integralcable:Silicone6i.Integralunderwatercable6j.1/2-14conduitfittingwith5ftof4conductorPVCcable6q.Integralcable:Polyurethane6v.Phoenixconnectoronendofcable

Shunt calibration

8a.Precisioninternalresistor8

Bridge type 11a.Squarebridge8

11b.Symmetricalbridge8 11c.Squareandsymmetricalbridge8 31a.Dualbridge

Bridge resistance

12b.5000ohm(foil)(max.250°F)

Zero and span adjustment

14a.Noaccesstozeroandspanadjustment

Electrical connector orientation

15a.Horizontalelectricalexitportorientation15b.Verticalelectricalexitportorientation15c.Radialelectricalexitportorientation15d.Connectoronendofcable

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration8

53t.TEDSIEEE1451.4module9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl5

Rod End In-Line Compression/Tension Load CellMOUNTING DIMENSIONS

TYPICAL SYSTEM DIAGRAM

Unamplified only Amplified only

Range (lb) D mm [in] T L2 mm [in] L1 mm [in] A mm [in] B mm [in] E mm [in] F mm [in]

2000to5000 44,45[1.75] 3/4-16UNF 24,13[0.95] 66,80[2.63] 19,05[0.75] 20,82[0.82] 49,53[1.95] 38,1[1.50]

10000to15000 63,5[2.50] 11/2-12UNF 44,45[1.75] 114,3[4.50] 19,05[0.75] 20,82[0.82] 49,53[1.95] 38,1[1.50]

25000to50000 88,9[3.50] 2-12UNF 57,15[2.25] 146,05[5.75] 19,05[0.75] 20,82[0.82] 49,53[1.95] 38,1[1.50]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

008658-2-EN IL50 GLO January 2010Copyright © 2010 Honeywell International Inc. All rights reserved.

Model RGH Rod End In-Line Compression/Tension Load Cell

Sensing and Control

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422

www.honeywell.com

NOTES

1. Allowablemaximumloads–maximumloadtobeappliedwithoutdamage.2

2. Withoutdamage-loadingtothislevelwillnotcauseexcessivezeroshift or performance degradation. The user must consider fatigue lifeforlongtermuseandstructuralintegrity.Allstructurallycriticalapplications(overheadloading,etc.)shouldalwaysbedesignedwith safety redundant load paths.

3. Interconnectingshuntcal.1terminalwithshuntcal.2terminalprovides50%(unamplifiedunits),75%(4mAto20mAthree-wireunits)or80%(voltageamplifiedunits)offullscaleoutputforquickcalibration.Shuntcalibrationcomesstandardwithinternalampli-fieroption2a,2b,2c,2tand2j.

4. O=Orange;Y=Yellow;B=Blue;Bl=Black;R=Red;Br=Brown;W=White;G=Green.Colorspecifyingcableandnumberorletterspecifying connector.

5. Nomatingconnectornecessaryforcableoption.6. Cannotusewithoptions1c,1e,1f,1g,1h,or1i.7. Onlyavailablewithoption2bor2c.8. Notavailablewithamplifiedoption.9. ConsultfactoryforTEDSavailabilitywithamplifiedmodels.10. Terminationdependent;consultfactory.11. ThisunitcalibratedtoImperial(non-Metric)units.12. 5000ohmbridgerequired.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed tootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystop devices or in any other application where failure of theproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthisdatasheetisforreferenceonly.DONOTUSEthisdocumentasproductinstallation information.

•Completeinstallation,operationandmaintenanceinformation is provided in the instructions supplied with each product.

Failure to comply with these instructions could result in death or serious injury.

Find out more

Honeywell serves its customers

through a worldwide network of

sales offices, representatives

anddistributors.Forapplication

assistance, current specifica-

tions, pricing or name of the

nearestAuthorizedDistributor,

contact your local sales office.

To learn more about Honeywell’s

test and measurement products,

call +1-614-850-5000, visit

www.honeywell.com/sensotec,

or e-mail inquiries to

[email protected]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Rod End In-line Tension/Compression Load CellModel RGM

FEATURES• 2000lbto50000lbrange

• Male/malethreads

• Stainlesssteel,all-weldedconstruction

• 1mV/Vnominal(standard);0Vdcto5Vdcor4mAto20

mAoutputs(optional)

• Compression/tension

• 0.25%accuracy

• CEapproved10

DESCRIPTIONTheModelRGMIn-Lineloadcellsarehighquality,stainless

steel,ruggedloadcellscapableofwithstandingsignificant

off-axisloads,makingthemanidealchoiceforin-linecompres-

sionmeasurementortensionmeasurementwheresideloading

cannotbecompletelycontrolled.Theflexiblemountingoptions

makeapplicationseasiertoimplement,andtheallstainless

steel,hermeticconstructioniswellsuitedtocorrosiveandvery

highhumidityenvironments.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model RGMPERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadranges11 2000,3000,4000,5000,10000,15000,25000,50000lb

Accuracy ±0.25%fullscale

Linearity ±0.25%fullscale

Hysteresis ±0.25%fullscale

Non-repeatability ±0.05%fullscale

Output(tolerance) 1mV/V(nominal)

Operation Tension/compression

Resolution Infinite

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature,operating -54°Cto121°C[-65°Fto250°F]

Temperature,compensated 15°Cto71°C[60°Fto160°F]

Temperatureeffect,zero 0.005%fullscale/°F

Temperatureeffect,span 0.005%fullscale/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bondedfoil

Excitation(calibration) 10Vdc

Excitation(acceptable) Upto15VdcorVac

Insulationresistance 5000mOhm@50Vdc

Bridgeresistance(toler-ance)

700ohm

Zerobalance(tolerance) ±3%fullscale

Shuntcalibrationdata Included

Electricaltermination(std) PTIH-10-6Porequivalent(hermeticstainless)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximumallowableload 150%FS1

Weight Seetable

Material Stainlesssteel

Lifecycles(approx) >10millioncycles

Deflectionfullscale Seetable

Naturalfrequency Seetable

RANGE CODES

Range Code Available ranges

DL 2000lb

DN 3000lb

DP 4000lb

DR 5000lb

DV 10000lb

EJ 15000lb

EM 25000lb

EP 50000lb

WIRING CODES

Connector Unamplified (Std.)

A (+)excitation

B (+)excitation

C (-)excitation

D (-)excitation

E (-)output

F (+)output

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb) Deflection at full scale mm [in]

Ringing fre-quency (Hz)

Weight kg [lb]

2000 0,025[0.001] 10000 0,55[1.2]

3000 0,025[0.001] 12000 0,55[1.2]

4000 0.038[0.0015] 13000 0,59[1.3]

5000 0,050[0.002] 15000 0,63[1.4]

10000 0,050[0.002] 10000 1,3[2.9]

15000 0,050[0.002] 10000 1,3[2.9]

25000 0,050[0.002] 6500 4,3[9.5]

50000 0,076[0.003] 7000 4,3[9.5]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Rod End In-Line Compression/Tension Load CellINTERNAL AMPLIFIERS

Amplifier specifica-tions

Voltage output: Option 2b

Voltage output: Option 2c

Voltage output: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Option 2n (2N)***

Output signal ±5V 0Vto5Vor±5V@45mA

0Vto10Vor±10V@45mA

4mAto20mA 4mAto20mA 4mAto20mA

Input power (voltage)

±15Vor26Vdcto32Vdc

11Vdcto28Vdc 15Vdcto28Vdc 22Vdcto32Vdc 15Vdcto40Vdc 9Vdcto28Vdc

Input power (current)

45mA 40mA 40mA 65mA 4mAto28mA 4mAto24mA

Freq. resp (amp)

3000Hz 3000Hz 3000Hz 2500Hz 300Hz 2000Hz

Power supply rej.

60db 60db 60db 60db 60db 60db

Operating temp.

-20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F

Reverse volt-age protec-tion

Yes Yes Yes Yes Yes Yes

Short cir. protection

Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)4

A(+)SupplyBOutputcommonCSupplyreturnD(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBOutputcommon**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBOutputcommon**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBOutputcommon**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

Wiring code: cable4,5,6

R(+)SupplyBlOutputcommonGSupplyreturnW(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBlOutputcommon*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBlOutputcommon*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBlOutputcommon*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl(+)OutputWCaseground

R(+)SupplyBl(+)OutputWCaseground

*Blackandgreenwiresareinternallyconnected.**PinsBandCareinternallyconnected.***SeeourWebsiteforthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.

ALLOWABLE MAXIMUM LOADS2

Capacity (lb) Side load (lb) (% of load capac-ity)

Torque (lb-in)(% of load capac-ity)

2000 20% 20%

3000 20% 20%

4000 20% 20%

5000 20% 20%

10000 20% 20%

15000 20% 20%

25000 20% 20%

50000 20% 20%

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model RGMOPTION CODES

Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 2K,3K,4K,5K,10K,15K,25K,50K

Temperature compensa-tion

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F

1g.70°Fto325°F8

1h.70°Fto400°F8

1i.-65°Fto250°F8

1j.0°Cto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal amplifiers

2u.Unamplified,mV/Voutput2b.4wire,±5Vdcoutput2c.0Vdcto5Vdc

2j.4mAto20mA(three-wire)output2k.4mAto20mA(two-wire)12

2t.0Vdcto10Vdcoutput

Internal amp enhance-ments

3a.Input/outputisolation7

3d.Remotebufferedshuntcalibration

Electrical termination

6a.BendixPTIH-10-6P(orequivalent)6-pin,(max.250°F)(ranges50000lbandbelow)

6b.MSconnectorMS3102E-14S-6P(mateswithMS3106E-14S-6),(max.160°F)(rangesabove50000lb)6

6e.Integralcable:Teflon6f.Integralcable:PVC

6g.Integralcable:Neoprene6h.Integralcable:Silicone6i.Integralunderwatercable6j.1/2-14conduitfittingwith5ftof4conductorPVCcable6q.Integralcable:Polyurethane6v.Phoenixconnectoronendofcable

Shunt calibration

8a.Precisioninternalresistor8

Bridge type 11a.Squarebridge8

11b.Symmetricalbridge811c.Squareandsymmetricalbridge831a.Dualbridge

Bridge resistance

12b.5000ohm(foil)(max.250°F)

Zero and span adjustment

14a.Noaccesstozeroandspanadjustment

Electrical connector orientation

15a.Horizontalelectricalexitportorientation15b.Verticalelectricalexitportorientation15c.Radialelectricalexitportorientation15d.Connectoronendofcable

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration8

53t.TEDSIEEE1451.4module9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl5

Rod End In-Line Compression/Tension Load CellMOUNTING DIMENSIONS

TYPICAL SYSTEM DIAGRAM

Unamplified only Amplified only

Range (lb) D mm [in] T L2 mm [in] L1 mm [in] A mm [in] B mm [in] E mm [in] F mm [in]

2000to5000 44,45[1.75] 3/4-16UNF 24,13[0.95] 66,80[2.63] 19,05[0.75] 20,82[0.82] 49,53[1.95] 38,1[1.50]

10000to15000 63,5[2.50] 11/2-12UNF 44,45[1.75] 88,9[3.50] 19,05[0.75] 20,82[0.82] 49,53[1.95] 38,1[1.50]

25000to50000 88,9[3.50] 2-12UNF 57,15[2.25] 88,9[3.50] 19,05[0.75] 20,82[0.82] 49,53[1.95] 38,1[1.50]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

008657-3-EN IL50 GLO January 2010Copyright © 2010 Honeywell International Inc. All rights reserved.

Model RGM Rod End In-Line Compression/Tension Load Cell

Sensing and Control

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422

www.honeywell.com

NOTES

1. Allowablemaximumloads–maximumloadtobeappliedwithoutdamage.2

2. Withoutdamage-loadingtothislevelwillnotcauseexcessivezeroshiftorperformancedegradation.Theusermustconsiderfatiguelifeforlongtermuseandstructuralintegrity.Allstructurallycriticalapplications(overheadloading,etc.)shouldalwaysbedesignedwithsafetyredundantloadpaths.

3. Interconnectingshuntcal.1terminalwithshuntcal.2terminalprovides50%(unamplifiedunits),75%(4mAto20mAthree-wireunits)or80%(voltageamplifiedunits)offullscaleoutputforquickcalibration.Shuntcalibrationcomesstandardwithinternalampli-fieroption2a,2b,2c,2tand2j.

4. O=Orange;Y=Yellow;B=Blue;Bl=Black;R=Red;Br=Brown;W=White;G=Green.Colorspecifyingcableandnumberorletterspecifyingconnector.

5. Nomatingconnectornecessaryforcableoption.6. Cannotbeusedwithoptions1c,1e,1f,1g,1h,or1i.7. Onlyavailablewithoption2bor2c.8. Notavailablewithamplifiedoption.9. ConsultfactoryforTEDSavailabilitywithamplifiedmodels.10. Terminationdependent;consultfactory.11. ThisunitcalibratedtoImperial(non-Metric)units.12. 5000ohmbridgerequired.

Find out more

Honeywellservesitscustomers

throughaworldwidenetworkof

salesoffices,representatives

anddistributors.Forapplication

assistance,currentspecifica-

tions,pricingornameofthe

nearestAuthorizedDistributor,

contactyourlocalsalesoffice.

TolearnmoreaboutHoneywell’s

testandmeasurementproducts,

call+1-614-850-5000,visit

www.honeywell.com/sensotec,

ore-mailinquiriesto

[email protected]

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeingfreeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywellduringtheperiodofcoverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliteratureandtheHoneywellwebsite,itisuptothecustomertodeterminethesuitabilityoftheproductintheapplication.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthisdatasheetisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.

•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression In-Line Load CellModel 3124

DESCRIPTIONThe small-diameter, cost-efficient load cells are designed to

be used in applications that require an ability to mount in an

existing system with restricted working area. They are commonly

used in fluid power transfer systems. Their low cost and ease of

mounting allow simultaneous testing of multi-element systems.

They may be directly attached to the piston rod of a hydraulic

cylinder. Side-mounted cable connectors allow cable assemblies

to be supported without affecting movement of the cell during

tension or compression loading.

FEATURES• 5000lbto25000lbrange

• 0.25%non-linearity

• 0.15%hysteresis

• Adaptsdirectlytohydrauliccylinder

• Smalldiameterallowsmountinginrestrictedareas

• Lowdeflection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3124

RANGE CODES

Range Code Available ranges

DR 5000lb

DV 10000lb

EJ 15000lb

EL 20000lb

EM 25000lb

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadrange1 5000,10000,15000,20000,25000lb

Non-linearity ±0.25%ofratedoutput

Hysteresis ±0.15%ofratedoutput

Repeatability ±0.05%ofratedoutput

Output @ rated capacity ±2mV/V(nominal)

Operation Tension/compression

Resolution Infinite

Standard calibration Tension(+)andcompression(-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated 21°Cto77°C[70°Fto170°F]

Temperature effect, zero ±0.002%ofratedoutput/°F

Temperature effect, output ±0.002%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Foil

Excitation(maximum) 20VdcorVacRMS

Insulation resistance >5000mOhm@50Vdc

Bridge resistance (tolerance)

350ohm

Number of bridges 1or2

Zero balance ±1.0%

MECHANICAL SPECIFICATIONS

Characteristic Measure

Static overload capacity 150%ofnominalcapacity

Material Carbonsteel

Natural frequency See table

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output Input

Serial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3124

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

AmplifierUniversal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000SC2001 SC3004GM NK HH7541 7558 7561-PSD

Display Units

Mating Connectors & Cables

OR

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

064-LW13621 Mating connector7200-76-XX* Mating connector and six conductor cable (unamplified unit with sense leads but not shunt cal)7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable (unamplified sensor without sense leads)7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable for connection to 7541 7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable for connection to 7541

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Tension/Compression In-Line Load Cell

NATURAL FREQUENCYNominal load limit capacity Fz

Static extraneous load limits

lb N Static overload capacity (% of nominal capacity)

Fatigue capacity (% of nominal capacity)

Shear FX or FY (lb)

Bending MX or MY (lb-in)

Torque MZ (lb-in)

Deflection at nominal load limit (in)

Ringing frequency (Hz)

5K 20K 150 n/a 250 750 15000 0.005 4600

10K 50K 150 n/a 250 700 1100 0.005 6400

15K 75K 150 n/a 450 1300 2100 0.005 7700

20K 100K 150 n/a 650 2000 3000 0.005 8800

25K 125K 150 n/a 950 2700 4500 0.005 9600

Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in] G cm [in] H cm [in]

3124 11,43[4.50] 2,54[1.0] 0,97[0.38] 2,06[0.81] 3,81[1.50] 3,51[1.38] 6,20[2.44] 4,37[1.72]

MOUNTING DIMENSIONS

1.0-14 THD.B DEEP

E DIA.

F DIA.

G

D

A

C

B

H

EHEX

RECEP.MS-3102E-14S-5P

1.0-14 THD.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008661-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3124 Tension/Compression In-Line Load Cell

NOTES

1.ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression In-Line Load CellModel 3161

DESCRIPTIONThe small-diameter, cost-efficient, fatigue-resistant load cells

are designed to be used in applications that require an ability to

mount in an existing system with restricted working area. They

are commonly used in fluid power transfer systems. Their low

cost and ease of mounting allow simultaneous testing of multi-

element systems.

They may be directly attached to the piston rod of a hydraulic

cylinder. Side-mounted cable connectors allow cable assemblies

to be supported without affecting movement of the cell during

tension or compression loading.

FEATURES• 2000lbto25000lbrange

• 0.15%linearity

• 0.1%hysteresis

• Fatigueresistant

• Adaptsdirectlytohydrauliccylinder

• Smalldiameterallowsmountinginrestrictedareas

• Lowdeflection

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3161

RANGE CODES

Range Code Available ranges

DL 2000lb

DR 5000lb

DV 10000lb

EM 25000lb

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadrange1 2000,5000,10000,25000lb

Non-linearity ±0.15%ofratedoutput

Hysteresis ±0.1%ofratedoutput

Repeatability ±0.05%ofratedoutput

Output @ rated capacity ±2mV/V(nominal)

Operation Tension/compression

Resolution Infinite

Standard calibration Tension(+)andcompression(-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated 21°Cto77°C[70°Fto170°F]

Temperature effect, zero ±0.002%ofratedoutput/°F

Temperature effect, output ±0.002%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Foil

Excitation(maximum) 20VdcorVacRMS

Insulation resistance >5000mOhm@50Vdc

Bridge resistance (tolerance)

350ohm

Number of bridges 1or2

Zero balance ±1.0%

MECHANICAL SPECIFICATIONS

Characteristic Measure

Static overload capacity 150%ofnominalcapacity

Material Carbonsteel

Natural frequency See table

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output Input

Serial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3161

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

AmplifierUniversal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000SC2001 SC3004GM NK HH7541 7558 7561-PSD

Display Units

Mating Connectors & Cables

OR

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Tension/Compression In-Line Load Cell

NATURAL FREQUENCYNominal load limit capacity Fz

Static extraneous load limits

lb N Static overload capacity (% of nominal capacity)

Fatigue capacity (% of nominal capacity)

Shear FX or FY (lb)

Bending MX or MY (lb-in)

Torque MZ (lb-in)

Deflection at nominal load limit (in)

Ringing frequency (Hz)

2K 10K 150 100 850 3800 3500 0.003 5000

5K 20K 150 100 850 3800 3500 0.003 6200

10K 50K 150 100 850 3800 3500 0.003 7100

25K 125K 150 100 2040 6750 9600 0.003 11000

Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in] G cm [in] H cm [in]

3161 17,48[6.88] 2,54[1.0] 11,28[4.44] 4,29[1.69] 6,05[2.38] 1,27[0.50] 4,14[1.63] 0,64[0.25]

MOUNTING DIMENSIONS

D

D

F

C

C

G

OPTIONALDUAL BRIDGE

9/32 DIA. M DEEP4 HOLES EQUALLY SPACEDFOR SPANNER WRENCH

E

1.0-14 THD.

1.0-14 THD.B DEEP

RECEP.PT02E-10-6P

OPTIONALDUAL BRIDGE

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008660-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3161 Tension/Compression In-Line Load Cell

NOTES

1.ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Tension/Compression Donut Load CellModel 3336

DESCRIPTIONModel 3336 Tension/Compression Donut Load Cell features a

smooth thru-hole design for use in applications which require the

load structure to pass through the cell. The hollow load cells are

available for tension-compression loads in capacities of 5K, 10K

and 20K lbs.

The precision design and manufacture of this versatile

transducer style is the result of our experience in the metal

working industry and automotive applications.

FEATURES• 5000lbto5000lbrange

• Thru-holedesign

• Compactcolumnconstruction

• mV/Voutput

• 0.25%linearity

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3336

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load range1 5000, 10000, 20000 lb

Non-linearity ±0.25%ofratedoutput

Hysteresis ±0.15%ofratedoutput

Repeatability ±0.15%ofratedoutput

Output @ rated capacity ±2mV/V(nominal)

Operation Tension/compression

Resolution Infinite

Standardcalibration Tension(+)andcompression(-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]

Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F]

Temperature effect, zero ±0.002%ofratedoutput/°F

Temperature effect, output ±0.002%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation(maximum) 20VdcorVacRMS

Insulation resistance >5000mOhm@50Vdc

Bridge resistance, 5K lb 350 ohm

Bridgeresistance,(tol.)10K, 20 K lb

700 ohm

Number of bridges 1 or 2

Zero balance ±1.0%

Electrical termination MS3102E-14S-5P

MECHANICAL SPECIFICATIONS

Characteristic Measure

Staticoverloadcapacity 150%ofnominalcapacity

Material Aluminum

Natural frequency Seetable

WIRING CODES

Cable

Red (+)excitation

Black (-)excitation

Green (+)output

White (-)output

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output Input

Serial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3336

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

AmplifierUniversal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000SC2001 SC3004GM NK HH7541 7558 7561-PSD

Display Units

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

OR

064-LW13621 Mating connector7200-76-XX* Mating connector and six conductor cable (unamplified unit with sense leads but not shunt cal)7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable (unamplified sensor without sense leads)7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable for connection to 7541 7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable for connection to 7541

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Tension/Compression Donut Load Cell

NATURAL FREQUENCYNominal load limit capacity Fz

Static extraneous load limits

lb N Static over-load capacity (% of nominal capacity)

Shear FX or FY (lb)

Bending MX or MY (lb-in)

Torque MZ (lb-in)

Deflection at nominal load limit (in)

Ringing fre-quency (Hz)

5K 20K 150 550 12K 1850 0.005 1100

10K 50K 150 1400 31K 3750 0.005 1500

20K 100K 150 2650 62K 14K 0.005 2200

Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in]

3336 22,86 [9] 12,70 [5] 8,26 [3.25] 1,91 [0.75] 12,40 [4.88] 17,78 [7]

MOUNTING DIMENSIONS

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985 Douglas Drive North

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008652-2-EN IL50 GLO December 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3336 Tension/Compression Donut Load Cell

NOTES

1. ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Compression Donut Load CellModel 3632

DESCRIPTIONModel 3632 Compression Donut Load Cell features a smooth

thru-hole design for use in applications which require the load

structure to pass through the cell. The hollow load cells are

available for compression only loads in capacities of 25K, 50K

and 100K lbs. For optimum performance, this load cell must be

mounted between load surfaces which are flat and parallel.

FEATURES• 25000lbto100000lbrange

• Thru-holedesign

• Compactcolumnconstruction

• mV/Voutput

• 0.15%linearity

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3632

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load range1 25000, 50000, 100000 lb

Non-linearity ±0.15%ofratedoutput

Hysteresis ±0.15%ofratedoutput

Repeatability ±0.15%ofratedoutput

Output @ rated capacity 2mV/V(nominal)

Operation Compression

Resolution Infinite

Standardcalibration Tension(+)andcompression(-)

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 93 °C [-65 °F to 200 °F]

Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F]

Temperature effect, zero ±0.002%ofratedoutput/°F

Temperature effect, output ±0.002%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation(maximum) 20VdcorVacRMS

Insulation resistance >5000mOhm@50Vdc

Bridge resistance, 25K lb, 50K lb

480 ohm

Bridge resistance, 100K lb 240 ohm

Number of bridges 1

Zero balance ±1.0%

Electrical termination PT02E-10-6P

MECHANICAL SPECIFICATIONS

Characteristic Measure

Staticoverloadcapacity 150%ofnominalcapacity

Material Carbon steel

Natural frequency Seetable

WIRING CODES

Cable

Red (+)excitation

Black (-)excitation

Green (+)output

White (-)output

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output Input

Serial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3632

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

AmplifierUniversal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000SC2001 SC3004GM NK HH7541 7558 7561-PSD

Display Units

Mating Connectors & Cables

OR

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Compression Donut Load Cell

NATURAL FREQUENCYNominal load limit capacity Fz

Static extraneous load limits

lb N Static over-load capacity (% of nominal capacity)

Shear FX or FY (lb)

Bending MX or MY (lb-in)

Torque MZ (lb-in)

Deflection at nominal load limit (in)

Ringing fre-quency (Hz)

25K 125K 150 2750 18K 3K 0.005 5000

50K 200K 150 5500 36K 13K 0.005 7000

100K 500K 150 13K 91K 27K 0.005 10000

Model A cm [in] B cm [in] C cm [in] D cm [in] E cm [in] F cm [in] G cm [in] H cm [in]

3632 10,16 [4] 5,08 [2] 7,62 [3] 5,08 [2] 2,54 [1] 8,26 [3.25] 0,15 [0.06] 4,78 [1.88]

MOUNTING DIMENSIONS

B DIA.

H

G

D

E

C

A DIA.

F

RECEP.PT02E-10-6P

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985 Douglas Drive North

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008651-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3632 Compression Donut Load Cell

NOTES

1. ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

High Capacity Compact Compression Load CellModel MPB

DESCRIPTIONThe compact Model MPB Load Cells are designed for

applications requiring high capacity yet where space restrictions

require that the cell be small in size. The Model MPB will

measure compression load forces in ranges between 15,000 to

2,000,000 pounds.

Applications include impact testing and mine shaft roof

simulations. The diameter of these load cells range between

1.25 in and 10 in while the height ranges between approximately

0.63 in and 14 in depending on the load range desired.

FEATURES• 8tonto1000tonrange

• Stainlesssteel

• mV/Voutput

• 0.25%accuracy

• CEapproved

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model MPB

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges9 1 ton to 1000 ton

Accuracy ±0.25%bestfitstraightline2

Non-repeatability ±0.02%fullscale

Output (tolerance) 2mV/V(nominal)

Operation Compression

Resolution Infinite

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded foil

Excitation(calibration) 10Vdc

Insulation resistance 5,000mOhm@50Vdc

Bridge resistance (toler-ance)

350 ohm (nominal)

Zero balance (tolerance) ±1%offullscale

Shuntcalibrationdata Included

Electricaltermination(std)1 ton to 5 ton

Cable

Electricaltermination(std)10 ton to 1000 ton

Connector

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 150%FS3

Material All welded stainless steel

Life cycles (approx.) 1 million cycles

WIRING CODES

Connector Unamplified

A (+) excitation

B (+) excitation

C (-) excitation

D (-) excitation

E (-) output

F (+) output

Wire

Red (+) excitation

Black (-) excitation

Green (-) output

White (+) output

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -57°Cto121°C[-70°Fto250°F]

Temperature, compensated 21°Cto71°C[70°Fto160°F]

Temperature, storage -73°Cto149°C[-100°Fto300°F]

Temperature effect, zero 0.005%fullscale/°F

Temperature effect, span 0.005%fullscale/°F

RANGE CODES

Range Code

Available ranges Range Code

Available ranges

DL 1 ton ET 50 ton

DR 2.5 ton FL 100 ton

DV 5 ton FR 250 ton

EL 10 ton FT 500 ton

EP 25 ton FV 1000 ton

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

High Capacity Compact Compression Load Cell

INTERNAL AMPLIFIERS

Amplifier specifica-tions

Voltage out-put: Option 2a

Voltage out-put: Option 2b

Vehicle volt-age output: Option 2c

Vehicle volt-age output: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Op-tion 2n (2N)***

Output signal

0Vto5V ±5V 0Vto5Vor±5V@45mA

0Vto10Vor±10V@45mA

4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA

Input power (voltage)

±15Vor26Vdcto32Vdc

±15Vor26Vdcto32Vdc

18Vdcto28Vdc

15Vdcto28Vdc

22Vdcto32Vdc

9Vdcto32Vdc 9Vdcto 28Vdc

Input power (current)

45 mA 45 mA 40 mA 40 mA 65 mA 4mAto28mA 4 mA to 24 mA

Freq. resp (amp)

3000 Hz 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz

Power sup-ply rej.

60 db 60 db 60 db 60 db 60 db 60 db 60 db

Operating temp.

-20°Fto185°F -20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F

Reverse voltage protection

Yes Yes Yes Yes Yes Yes Yes

Short cir. protection

Momentary Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)

A(+)SupplyB(-)Output/supplyC(-)SupplyD (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB(-)Output/supplyC(-)SupplyD (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB Output com-mon**CSupplyreturn**D (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB (-) outputCSupplyreturnD (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB Output com-mon**CSupplyreturn**D (+) OutputEShuntcal1FShuntcal2

A(+)SupplyB No connectionC No connectionD (+) OutputECasegroundFNoconnection

A(+)SupplyB No connectionC No connectionD (+) OutputECasegroundFNoconnection

Wiring code: cable4,5,6

R(+)SupplyBr(-)SupplyO(-)Output/supplyG (+) OutputBShuntcal1YShuntcal2

R(+)SupplyBr(-)SupplyO(-)Output/supplyG (+) OutputBShuntcal1YShuntcal2

R(+)SupplyBl Output com-mon*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBlSupplyreturnG (+) OutputW (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output com-mon*GSupplyreturn*W (+) OutputBShuntcal1BrShuntcal2

R(+)SupplyBl (+) OutputW Case ground

R(+)SupplyBl (+) OutputW Case ground

* Black and green wires are internally connected.** Pins B and C are internally connected.***SeeourWebsiteforthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model MPB

NOTES

1. Forstandardconfigurationwithsphericalradius,ahardenedsurface is recommended to maintain the best loading conditions. RC42 is recommended minimum hardness. Bearing lubricant at loading interface recommended for maximum life.

2. Accuraciesstatedareexpectedforbest-fit,straight-lineforaller-rors including linearity, hysteresis and non-repeatability thru zero.

3. Allowable maximum loads – Maximum load to be applied without damage.4

4. Withoutdamage–loadingtothislevelwillnotcauseexcessivezero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structur-allycriticalapplications(overheadloading,etc.)shouldalwaysbedesigned with safety redundant load paths.

5. Specialwiringcode.6. Notavailablewithoption1e,1f,1g,1h,or1i.7. Amplifieroptionnotavailablewithlowranges.Consultfactory.8. ConsultfactoryforTEDSavailabilitywithamplifiedmodels.9. This unit calibrated to Imperial (non-Metric) units.10. Non-amplifiedonly.11. 5000 ohm bridge required.

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 1, 2.5, 5, 10, 25, 50, 100, 250, 500, 1000 ton

Temperature compensa-tion

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F

1g.70°Fto325°F10

1h.70°Fto400°F10

1i.-65°Fto250°F10

1j. 0 °C to 50 °C1k.-20°Cto85°C1m. -25 °C to 110 °C

Internal amplifiers6, 7

2a.Four-wire,0Vdcto5Vdcoutput

2c.0Vdcto5Vdc2j. 4 mA to 20 mA (three-

wire) output2k. 4 mA to 20 mA (two-

wire)11

2n (2N) 4 mA to 20 mA (two-wire) intrinsically safe11

2t.0Vdcto10Vdcoutput

2u.Unamplified,mV/Voutput

Electrical termination

6a. Bendix PTIH-10-6P (orequivalent),6-pin(max.250°F)

6b.MS3102E-14S-6Pconnector (10 ton to 1000 ton range)5

6e. Integral cable: Teflon (1 ton to 5 ton range)

6f.Integralcable:PVC(-20°Fto160°F)

6g. Integral cable: Neoprene(0°Fto180°F)6

6i. Integral underwater cable(max.180°F)6

6j.1/2-14conduitfitting6q. Integral cable: Poly-

urethane6v.Phoenixconnector

on end of cable

Electrical connector orientation

15a. Horizontal electrical exit port orientation15b.Verticalelectricalexitportorientation15c. Radial electrical exit port orientation

Shunt cali-bration

8a.Precisioninternalresistor(max.250°F)10

Bridge type 11a.Squarebridge10

11b.Symmetricalbridge10 11c.Squareandsymmetricalbridge10 31a. Dual bridge

Bridge resist-ance

12b.5000ohm(foil)(max.250°F)

Special cali-bration

30a.Positiveincompression,compressiontestingonly

9a.10point(5up/5down)20%increments@70°F9b.20point(10up/10down)10%increments@

70°F9c.ASTME-74calibration9e.CEmark30c.Negativeincompression,compressiontesting

only

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration5

53t.TEDSIEEE1451.4module8

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008648-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model MPB High Capacity Compact Compression Load Cell

Warranty. Honeywell warrants goods of its manufacture as being freeofdefectivematerialsandfaultyworkmanship.Honeywell’sstandard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement orconsultyourlocalsalesofficeforspecificwarrantydetails.Ifwarranted goods are returned to Honeywell during the period of coverage,Honeywellwillrepairorreplace,atitsoption,withoutchargethoseitemsitfindsdefective.The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

Whileweprovideapplicationassistancepersonally,throughourliterature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupplyisbelievedtobeaccurateandreliableasofthisprinting.However,weassumenoresponsibilityforitsuse.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

MOUNTING DIMENSIONS

Capaci-ty (tons) (v.s.)

D0 mm [in] D1 mm [in] D2 mm [in] L1 mm [in] L2 mm [in] L3 mm [in] H mm [in] Thread lifting eye

Optional bottom thread

1 6,6[0.26] 22,1[0.87] 9,4[0.37] 19,05[0.75] 0,51[0.02] 1,52[0.06] 9,53[0.375] NA 8-32UNCx0.18indeep

2.5 6,6[0.26] 22,1[0.87] 9,4[0.37] 19,05[0.75] 0,51[0.02] 1,52[0.06] 9,53[0.375] NA 8-32UNCx0.18indeep

5 10,41[0.41] 24,89[0.98] 13,46[0.53] 22,35[0.88] 1,02[0.04] 1,52[0.06] 9,53[0.375] NA 8-32UNCx0.18indeep

10 19,05[0.75] 37,85[1.49] 19,05[0.75] 28,45[1.12] 1,52[0.06] 4,06[0.16] 9,53[0.375] NA 1/4-28UNFx0.25 in deep

25 29,97[1.18] 49,78[1.96] 29,97[1.18] 44,96[1.77] 3,05[0.12] 7,62[0.30] 19,05[0.75] NA 1/4-28UNFx0.25 in deep

50 40,39[1.59] 61,98[2.44] 40,39[1.59] 64,0[2.52] 4,57[0.18] 4,83[0.19] 38,1[1.5] NA 3/8-24UNFx0.38indeep

100 57,15[2.25] 81,03[3.19] 57,15[2.25] 85,85[3.38] 6,35[0.25] 17,53[0.69] 38,1[1.5] NA 3/8-24UNFx0.38indeep

250 90,68[3.57] 112,78[4.44] 90,68[3.57] 135,89[5.35] 6,35[0.25] 43,18[1.7] 38,1[1.5] 1/4-28 3/4-16UNFx0.75 in deep

500 128,27[5.05] 163,58[6.44] 128,27[5.05] 192,28[7.57] 6,35[0.25] 66,04[2.6] 38,1[1.5] 1/4-28 3/4-16UNFx0.75 in deep

1000 181,36[7.14] 214,38[8.44] 181,36[7.14] 264,41 [10.41]

6,35[0.25] 101,6[4.0] 38,1[1.5] 3/8-16 1-12UNFx1.0 in deep

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Thru-Hole Load CellModel D

DESCRIPTIONThe Model D Donut Shaped Load Cell features a smooth thru-

hole design often ideal for applications which require the load

structure to pass directly through the cell. Such applications

include bolt force measurements, clamping forces, and

monitoring overloads. Load ranges as low as 150 grams and as

great as 30,000 pounds can be measured within a maximum full

scale non-linearity and hysteresis of ±0.5 % F.S., respectively.

These models are used in compression applications and

are available in multiple hole and frame sizes. For optimum

performance, these cells must be mounted between load

surfaces which are flat and parallel. The Model D miniature load

cell is designed to have a minimum thickness.

FEATURES• 150gto30000lb

• Thru-holedesign

• Flexibleconfiguration

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model D

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges8 150 g to 30000 lb

Accuracy 1 %

Linearity (max.) ±0.5 % full scale

Hysteresis (max.) ±0.5 % full scale

Non-repeatability (max.) ±0.1 % full scale

Output (tolerance) 150 g to 1000 g

20 mV/V (nominal)

Output (tolerance) 5 lb to 30000 lb

2 mV/V (nominal)

Operation Compression

Resolution Infinite

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type150 g to 1000 g

Semiconductor

Strain gage type5 lb to 30000 lb

Bonded foil

Excitation (calibration) 150 g to 1000 g

5 Vdc

Excitation (calibration)5 lb to 30000 lb

10 Vdc

Insulation resistance 5000 mOhm @ 50 Vdc

Bridge resistance (toler-ance)150 g to 1000 g

500 ohm (nominal)

Bridge resistance (toler-ance) 5 lb to 30000 lb

350 ohm (nominal)

Zero balance (tolerance) ±1 % of full scale

Shunt calibration data Included

Electrical termination (std) Teflon cable (5 ft)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 150 % FS1

Weight note4

Material Stainless steel

Deflection full scale note4

Natural frequency note4

WIRING CODES

Wire

Red (+) excitation

Black (-) excitation

Green (-) output

White (+) output

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]

Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]

Temperature effect, zero 150 g to 1000 g

0.01 % full scale/°F

Temperature effect, zero 5 lb to 30000 lb

0.005 % full scale/°F

Temperature effect, span150 g to 1000 g

0.02 % full scale/°F

Temperature effect, span 5 lb to 30000 lb

0.010 % full scale/°F

RANGE CODES

Range Code

Available ranges Range Code

Available ranges

AL 150 g CR 500 lb

AN 250 g CV 1000 lb

AP 500 g DL 2000 lb

AR 1000 g DN 3000 lb

AT 5 lb DR 5000 lb

AV 10 lb DT 7500 lb

BL 25 lb DV 10000 lb

BN 50 lb EJ 15000 lb

BR 100 lb EL 20000 lb

CN 250 lb EN 30000 lb

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Thru-Hole Load Cell

MOUNTING DIMENSIONS

Ranges Order code ØOD mm [in]

ØID mm [in] H1 mm [in] H2 mm [in] H3 mm [in] ØD1 mm [in]

ØD2 mm [in]

150, 250, 500, 1000 g

BL912 12,7 [0.50] 2,54 [0.10] 3,81 [0.15] 0,51 [0.02] 0,25[0.01]

5,08 [0.20] 11,43 [0.45]

5, 10 lb BL912 25,4 [1.00] 5,08 [0.20] 7,11 [0.28] 0,76 [0.03] 0,51 [0.02] 6,60 [0.26] 21,59 [0.85]

25, 50, 100 lb

BL912 25,4 [1.00] 5,08 [0.20] 7,11 [0.28] 0,76 [0.03] 0,51 [0.02] 9,14 [0.36] 21,59 [0.85]

Frame A (100 to 2000 lb)

BL913 38,1 [1.50] See below 12,7 [0.50] 1,27 [0.05] 0,76 [0.03] 12,7 [0.50] 30,73 [1.21]

Frame B (250 to 10000 lb)

BL914 50,8 [2.00] See below 16,00 [0.63] 1,52 [0.06] 0,76 [0.03] 22,53[0.88]

42,67 [1.68]

Frame C (2000 to 30000 lb)

BL915 76,2 [3.00] See below 25,4 [1.0] 2,03 [0.08] 0,76 [0.03] 43,18 [1.70] 62,48 [2.46]

Listed above are four different order codes; BL912, BL913, BL914, BL915. The frame size selection guide below indicates that with a single shell size (outside diameter), different thru holes are available for order codes BL913, BL914 and BL915 (frames A, B, and C, respectively). To choose a product, firstselectthedesiredloadcapacity.Then,ifapplicable,choosethedesiredinnerdiameterandanappropriateframesize.Forexample,a250lbloadcell is available in the small frame size (A) with a nominal thru hole size of 1/8 in (P), 3/16 in (Q), 1/4 in (R) or 3/8 in (S) diameter, or in the medium frame size (B) with thru hole sizes up to 5/8 in (V). We manufacture the actual hole dimensions to provide some clearance; for example the 1/8 in (P) dimen-sion, the actual dimension is 0.128 in.

Hole letters P Q R S T V W Y Z

ØID (nom) 1/8 in 3/16 in 1/4 in 3/8 in 1/2 in 5/8 in 3/4 in 1 in 1 1/4 in

ØID (act) 0.128 in 0.193 in 0.266 in 0.391 in 0.532 in 0.656 in 0.781 in 1.032 in 1.281 in

100 lb A A A A NA NA NA NA NA

250 lb A or B A or B A or B A or B B B NA NA NA

500 lb A or B A or B A or B A or B B B NA NA NA

1000 lb A or B A or B A or B B B B NA NA NA

2000 lb A, B, or C A, B, or C A, B, or C B or C B or C B or C C C C

3000 lb B or C B or C B or C B or C B or C C C C C

5000 lb B or C B or C B or C B or C B or C C C C C

7500 lb B or C B or C B or C B or C B or C C C C C

10000 lb B or C B or C B or C B or C B or C C C C C

15000 lb C C C C C C C C C

20000 lb C C C C C C C C C

30000 lb C C C C C C C C C

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422 USA

+1-815-235-6847

www.honeywell.com/sensing

008649-2-EN IL50 GLO December 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model D Thru-Hole Load Cell

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 150 g, 250 g, 500 g, 1000 g; 5, 10, 25, 50, 100, 250, 500, 1000, 2000, 3000, 5000, 7500, 10000, 15000, 20000, 30000 lb

Temperature compensa-tion

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F

1f. 70 °F to 250 °F 1g. 70 °F to 325 °F3

1h. 70 °F to 400 °F3

1i. -65 °F to 250 °F

Internal am-plifiers

2u.Unamplified,mV/Voutput

Electrical termination

6e. Integral cable: Teflon (5 ft)6a. Bendix PTIH-10-6P (or equivalent), 6-pin (max.

250 °F) on end of cable6v. Phoenix connector on end of cable6i. Integral underwater cable6

Electrical connector orientation

15d. Connector on end of cable5

Load direc-tion

30a. Positive in compression, compression testing only

30c. Negative in compression, compression testing only

Shock and vibration

44a. Shock and vibration resistance

Interfaces 53s. Signature calibration5 (Inline)53t. TEDS IEEE 1451.4 module7 (Inline)

NOTES

1. Allowable maximum loads – maximum load to be applied without damage.2 Loads described allow for 100 % full scale axial loading

withthebendingloadsspecified.Torqueloadingmaximumiswith-out axial or other load. For any other combination consult factory.

2. Without damage – loading to this level will not cause excessive zero shift of performance degradation. The user must consider fatigue life for long term use and structural integrity. All structur-ally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

3. Only for ranges greater than or equal to 5 lb.4. Varies by features selected, consult factory.5. Be sure to specify electrical termination option 6a or 6v in option

code. For custom connector, consult factory.6. Dimension “H1” may increase with this option, consult factory. Not

available with option 1c, 1e, 1f, 1g, 1h, or 1i.7. Only available with integral cable units.8. This unit calibrated to Imperial (non-Metric) units.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your orderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywell during the period of coverage, Honeywell will repair orreplace,atitsoption,withoutchargethoseitemsitfindsdefective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Thru-Hole Load CellModel TH

DESCRIPTIONModel TH Donut Shaped Load Cell features a smooth thru-

hole design for use in applications which require the load

structure to pass through the cell. Such applications include

bolt force measurement, post or leg mount, and rolling mill

systems. Load ranges as low as 15,000 pounds and as great

as 200,000 pounds can be measured within a maximum full

scale non-linearity of ±0.25. This model is used in compression

applications. For optimum performance, this load cell must be

mounted between load surfaces which are flat and parallel. The

Model TH Donut Shaped Load Cell is designed to provide the

customer with an internal hole diameter which is large relative

to the outside diameter. The Model TH is a small size, high

capacity load cell.

FEATURES• 15000lbto200000lbrange

• Thru-holedesign

• Compactcolumnconstruction

• mV/Voutput

• 0.25%linearity

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model TH

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges3 15000 lb to 200000 lb

Accuracy 0.5%

Linearity (max.) ±0.25%fullscale

Hysteresis (max.) ±0.25%fullscale

Non-repeatability (max.) ±0.1%fullscale

Output (tolerance) 2mV/V(nominal)

Operation Compression

Resolution Infinite

RANGE CODES

Range codes Range

EJ 15000 lb

EL 20000 lb

EN 30000 lb

EP 50000 lb

ER 75000 lb

ET 100000 lb

FJ 150000 lb

FL 200000 lb

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Bonded foil

Excitation (calibration) 10Vdc

Insulation resistance 5,000mOhm@50Vdc

Bridge resistance 350 ohm

Zero balance ±1%fullscale

Electrical termination (std) Teflon cable (5 ft)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 150%FS1

Weight See table

Case material Stainless steel

Deflection full scale See table

Natural frequency See table

WIRING CODES

Cable Unamplified

Red (+) excitation

Black (-) excitation

Green (-) output

White (+) output

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54 °C to 121 °C [-65 °F to 250 °F]

Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]

Temperature effect, zero 0.005%fullscale/°F

Temperature effect, span 0.005%fullscale/°F

DEFLECTIONS AND RINGING FREQUENCIES

Capacity (lb) Deflection at full scale mm [in]

Ringing fre-quency (kHz)

Weight kg [lb]

15000 0,025 [0.001] 35 0,18 [0.4]

20000 0,025 [0.001] 35 0,18 [0.4]

30000 0,051 [0.002] 17 0,45 [1.0]

50000 0,051 [0.002] 17 0,45 [1.0]

75000 0,076 [0.003] 14 0,90 [2.0]

100000 0,076 [0.003] 14 0,90 [2.0]

150000 0,152 [0.006] 12 1,13 [2.5]

200000 0,102 [0.004] 10 2,72 [6]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Thru-Hole Load Cell

MOUNTING DIMENSIONS

Ranges (lb) H mm [in] OD mm [in] ID mm [in] D2 mm [in] D3 mm [in]

15000, 20000 38,1 [1.50] 38,1 [1.50] 19,3 [0.76] 26,92 [1.06] 29,21 [1.15]

30000, 50000 50,8 [ [2.00] 50,8 [ [2.00] 25,65 [1.01] 38,1 [1.50] 38,1 [1.50]

75000, 100000 63,5 [2.50] 63,5 [2.50] 32,60 [1.26] 47,75 [1.88] 47,75 [1.88]

150000 76,2 [3.00] 76,2 [3.00] 38,35 [1.51] 58,67 [2.31] 61,97 [2.44]

200000 88,9 [3.50] 88,9 [3.50] 44,70 [1.76] 69,85 [2.75] 88,9 [3.50]

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture pro-grams. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 15K, 20K, 30K, 50K, 75K, 100K, 150K, 200K

Temperature compensa-tion

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F1d. -20 °F to 130 °F1e. -20 °F to 200 °F 1f. 70 °F to 250 °F

1g. 70 °F to 325 °F1h. 70 °F to 400 °F1i. -65 °F to 250 °F1j. 0 °C to 50 °C1k. -20 °C to 85 °C1m. -25 °C to 110 °C

Internal am-plifiers

2u.Unamplified,mV/Voutput

Electrical termination

6a. Bendix PTIH-10-6P (or equivalent), 6-pin (max. 250 °F)

6b. MS connector MS3102E-14S-6P (mates with MS3106E-14S-6S) (max. 160 °F)4

6e. Integral cable: Teflon (5 ft range)

6f.Integralcable:PVC6g. Integral cable: Neo-

prene

6h. Integral cable: Silicone

6i. Integral underwater cable

6j.1/2-14conduitfittingwith 5 ft of 4 conduc-torPVCcable

6q. Integral cable: Poly-urethane

6v. Phoenix connector on end of cable

15d. Connector on end of cable

Shunt calibration

8a. Precision internal resistor

Special calibration

9a.10point(5up/5down)20%increments@70°F9b.20point(10up/10down)10%increments @ 70 °F9c. ASTM E-74 calibration30a. Positive in compression, compression testing

only30c. Negative in compression, compression testing

only

Bridge type 31a. Dual bridge

Bridge resistance

12b. 5000 ohm (foil)

Electrical connector orientation

15a. Horizontal electrical exit port orientation15b.Verticalelectricalexitportorientation15c. Radial electrical exit port orientation15d. Connector on end of cable

Shock and vibration

44a. Shock and vibration resistance

Interfaces 53e. Signature calibration53t. TEDS IEEE 1451.4 module

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Sensing and Control

Automation and Control Solutions

Honeywell

1985 Douglas Drive North

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008650-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model TH Thru-Hole Load Cell

TYPICAL SYSTEM DIAGRAM

NOTES

1. Allowable maximum loads – maximum load to be applied without damage.2

2. Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long-term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

3. This unit calibrated to Imperial (non-Metric) units.4. Cannot be used with options 1c, 1e, 1f, 1g, 1h, or 1i.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

For more information about Sensing and Control products, visit www.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Bolt and Engine Mount Force SensorModel 3719

DESCRIPTIONThe bolt force sensor is a unique transducer which is essentially

a hollow-compression strain gage load cell. It is designed to be

used with most strain gage indicators. The bolt force sensor is

a three-piece assembly consisting of: 1. a large hardened and

ground flat washer with one side beveled, 2. the sensor, and 3. a

small hardened and ground washer.

The three pieces are assembled for various applications. The

large washer isolates the sensor from the force application tool.

The beveled hole in this washer, which always faces away from

the sensor, provides clearance for the bolt head radius. When

a torque wrench is used, a torque vs. clamp force curve can be

generated. The 3719 bolt force sensor is designed for use in

fastener testing where the compression loading of the sensor

is induced by the tensile loading of the fastener. The bolt force

sensor must be used with the size fastener for which it was

designed.

FEATURES• Compact

• Highoutput

• Standardmodelsforboltssizeno.6thru2inand

up to 20 mm

• Sensorandwashers-carpenter440Cstainlesssteel

• Sensitivetoneitherboltnornut-appliedtorque

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3719PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load range1 1200 lb to 300000 lb

Non-linearity - ranges up to 25Klb(67KN)

±3.0 % of rated output

Non-linearity - ranges 30K lbandup(102KN)

±4.0%ofratedoutput

Hysteresisrangesupto25Klb(67KN)

±5.0 % of rated output

Hysteresis-ranges30Klbandup(102KN)

±7.0 % of rated output

Repeatability ±0.10 % of rated output

Output @ rated capacity ±2 mV/V to 3.5 mV/V depending on size (nominal)

Resolution Infinite

Standardcalibration Compression

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated 21°Cto77°C[70°Fto170°F]

Temperature effect, zero ranges up to 12K lb

±0.01%offullscale/°F

Temperature effect, zero ranges 18K lb and up

±0.007%offullscale/°F

Temperature effect, output ranges up to 12K lb

±0.02%ofreading/°F

Temperature effect, outputranges 18K lb and up

±0.0035%ofreading/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Excitation(maximum) 10VdcorVacRMS

Insulation resistance, bridge case

> 5000 mOhm @ 50 Vdc

Bridge resistance (tolerance)

350 ohm

Number of bridges 1

Zero balance ±1.0

MECHANICAL SPECIFICATIONS

Characteristic Measure

Staticoverloadcapacity 150 % of nominal capacity

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Bolt and Engine Mount Force SensorMOUNTING DIMENSIONSModel Bolt size Capacity lb C in ØD in ØA in ØB in T in

3719-138 No.6 1200 0.330 0.140 0.42 0.250 0.040

3719-164 No. 8 1800 0.330 0.166 0.47 0.300 0.040

3719-190 No. 10 2400 0.330 0.192 0.52 0.350 0.040

3719-250 1/4 5000 0.370 0.262 0.65 0.470 0.060

3719-312 5/16 7000 0.495 0.326 0.78 0.550 0.060

3719-375 3/8 10000 0.495 0.396 0.80 0.639 0.060

3719-437 7/16 12000 0.495 0.454 0.95 0.720 0.060

3719-500 1/2 20000 0.660 0.517 1.14 0.910 0.080

3719-562 9/16 25000 0.660 0.580 1.23 0.990 0.080

3719-625 5/8 30000 0.660 0.644 1.35 1.150 0.080

3719-750 3/4 45000 0.815 0.770 1.62 1.350 0.095

3719-875 7/8 60000 0.815 0.897 1.72 1.600 0.095

3719-1000 1 90000 0.815 1.024 2.00 1.800 0.095

3719-1125 1 1/8 80000 1.065 1.151 2.20 1.900 0.095

3719-1250 11/4 125000 1.125 1.279 2.40 2.250 0.125

3719-1500 1 1/2 190000 1.125 1.533 2.80 2.600 0.125

3719-1750 13/4 260000 1.300 1.787 3.20 3.000 0.150

3719-2000 2 300000 1.650 2.041 3.60 3.500 0.200

3719-6MM 6mm 17000* 9,40* 6,0* 16,3* 10,7* 1,5*

3719-7MM 7 mm 27000* 12,57* 7,1* 16,8* 12,2* 1,5*

3719-8MM 8 mm 31000* 12,57* 8,3* 19,8* 14,5* 1,5*

3719-9MM 9 mm 36000* 12,57* 9,0* 20,3* 15,2* 1,5*

3719-10MM 10 mm 46000* 12,57* 10,1* 20,3* 16,2* 1,5*

3719-12MM 12 mm 67000* 15,75* 12,0* 27,9 22,1* 1,5*

3719-14MM 14mm 102000* 16,76* 14,0* 31,8* 25,9* 2,0*

3719-15MM 15 mm 125000* 16,76* 15,5* 32,5* 26,4* 2,0*

3719-16MM 16mm 135000 16,76* 16,1* 34,3* 29,2* 2,0*

3719-18MM 18 mm 156000 19,94* 18,1* 36,8* 31,8* 2,0*

3719-20MM 20 mm 220000 20,70* 20,1* 43,2* 36,8* 2,4*

*CapacitiesinNewtons,*Dimensionsinmillimeters

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

008653-2-EN IL50 GLO March 2009Copyright © 2009 Honeywell International Inc. All rights reserved.

Model 3719 Bolt and Engine Mount Force Sensor

Sensing and Control

Honeywell

1985 Douglas Drive North

Golden Valley, MN 55422

www.honeywell.com

NOTES

1. ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywellwarrantsgoodsofitsmanufactureasbeing free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywellduringtheperiodofcoverage,Honeywellwillrepairor replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literatureandtheHoneywellwebsite,itisuptothecustomertodetermine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However,weassumenoresponsibilityforitsuse.

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Find out more

Honeywellservesitscustomers

through a worldwide network of

sales offices, representatives

anddistributors.Forapplication

assistance, current specifica-

tions, pricing or name of the

nearestAuthorizedDistributor,

contact your local sales office.

TolearnmoreaboutHoneywell’s

test and measurement products,

call +1-614-850-5000, visit

www.honeywell.com/sensotec,

or e-mail inquiries to

[email protected]

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Pedal Pressure Load CellModel 3663

DESCRIPTIONThe pedal pressure sensor mounts directly to the brake pedal

with its own mounting clamp. Load applied up to 1/2 inch off

center, produces less than a 0.5% error. Standard capacity

is 300 lbs. This load cell, which is used for brake pedal

force measurements by the automotive industry, finds many

production applications. It adapts to any of the pedal or bar

operated devices used in all production facilities.

FEATURES• 50lb,100lb,200lb,and300lbloadcapacity

• Lowoff-centerloadingerror

• Easymounting

• Ruggedloadsurface

• Integralcable

• Compactsize

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3663

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load range 50, 100, 200, 300 lb

Non-linearity ±0.25 % of rated output

Hysteresis ±0.1 % of rated output

Repeatability ±0.1 % of rated output

Output @ rated capacity 2 mV/V (nominal)

Operation Tension/compression

Resolution Infinite

Standard calibration Tension(+)andcompression(-)

RANGE CODES

Range Codes Range

BN 50 lb

BR 100 lb

CL 200 lb

CP 300 lb

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Strain gage type Foil

Excitation(maximum) 20VdcorVacRMS

Insulation resistance > 5000 mOhm @ 50 Vdc

Bridge resistance (toler-ance)

350 ohm

Zero balance ±2.0 %

Electricaltermination PT06W-12-10P

MECHANICAL SPECIFICATIONS

Characteristic Measure

Static overload capacity 150 % of nominal capacity

Safe overload rating 150 % of nominal capacity

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated 21°Cto77°C[70°Fto170°F]

Temperatureeffect,zero ±0.003%ofratedoutput/°F

Temperature effect, output ±0.003%ofreading/°F

MOUNTING DIMENSIONS

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3663

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

023-LW181-023-LF Mating Connector

** XX represents length in feet 20ft maximum

Mating Connectors & Cables

7220-109-XX** Mating connector & 4 conductor cable

BRAKE PEDALPAD

TWO ADJUSTABLECLAMPS

FURNISHED

2.0 DIA.

1 5/8

1 3/32

4 CONDUCTOR CABLE-8 FT.

RECEP.PT06W-12-10P

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008676-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model 3663 Pedal Pressure Load Cell

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Seat Belt Load CellModel 3419

DESCRIPTIONThe seat belt sensor’s design and calibration method essentially

make it independent of belt thickness, which may change under

load. It provides excellent repeatability without the need for the

extensive belt wrap.

FEATURES• Upto.1inofbeltthickness

• Smallsize

• Installswithout“threading”

• Lowsensitivitytobeltthicknesschange

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 3419

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Loadrange 3500 lb

Non-linearity ±2 % of rated output

Hysteresis ±4 % of rated output

Repeatability ±1.0%ofratedoutput

Output @ rated capacity 2 mV/V (nominal)

Operation Tension/compression

Resolution Infinite

Standardcalibration Tension (+) and compression (-)

RANGE CODES

Wire

Red (+) excitation

Black (-) excitation

Green (+) output

White (-) output

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation (maximum) 20VdcorVacRMS

Insulation resistance > 5000 mOhm @ 50 Vdc

Bridge resistance (toler-ance)

350 ohm

Zero balance ±2.0 %

Electrical termination 6 ft of four-conductor cable

MECHANICAL SPECIFICATIONS

Characteristic Measure

Staticoverloadcapacity 150%ofnominalcapacity

Weight 8oz

Band thickness 2,54mm[0.10in]

Band width 50,8mm[2.0in]

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated 21°Cto77°C[70°Fto170°F]

Temperatureeffect,zero ±0.003 % of rated output/°F

Temperature effect, output ±0.003 % of reading/°F

MOUNTING DIMENSIONS

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL 3419

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

023-LW181-023-LF Mating Connector7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal)7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal)7205-83-XX* Mating connector & 6 conductor cable (for connection to instrument 7541)7205-82-XX** Mating connector & 4 conductor cable (for connection to instrument 7541)

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

1.0

2.0

3-3/32

2.0

HINGE POINT FORBELT INSTALLATION& REMOVAL

REMOVABLE PINIS REINSERTEDBEFORE CLOSING

0.10 MAXBELT THICKNESS

6 FT 4 CONDUCTORCABLE

PIGTAILS

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008677-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Models 3419 Seat Belt Load Cell

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

X-Y Force SensorModel 6443

DESCRIPTIONThe X-Y force sensor is constructed of two strain gage bridges,

mounted at 90º, isolated by a flexure system. The complete

two-component system, including flexures, is machined from

one specially prepared metal billet to provide unusual structure

strength and to minimize crosstalk between the two transducers.

This unique sensor has excellent linearity characteristics and

maximum structure life.

FEATURES• Compactsize

• 0.1%linearityandhysteresis,respectively

• Simultaneousdual-axisreadings

• Minimalcrosstalk

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model 6443

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load range 6443(1000lbX,500lbY)6443-105(2000lbX,500lbY)6443-106(1500lbX,500lbY)

Non-linearity ±0.1%ofratedoutput

Hysteresis ±0.1%ofratedoutput

Repeatability ±0.05%ofratedoutput

Output @ rated capacity 2mV/V±0.25%(nominal)

Operation Tension/compression

Resolution Infinite

Standardcalibration Tension(+)andcompression(-)1

RANGE CODES

Wire

Red (+)excitation

Black (-)excitation

Green (+)output

White (-)output

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation(maximum) 20VdcorVacRMS

Insulation resistance >5000mOhm@50Vdc

Bridge resistance (toler-ance)

350ohm

Crosstalk 1%offullscale

Zero balance ±1.0%

Electrical termination MS-3102E-14S-5P(2)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Safeoverloadcapacity 150%ofratedcapacity

Material Carbonsteel

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto200°F]

Temperature, compensated 21°Cto77°C[70°Fto170°F]

Temperature effect, zero ±0.002%ofratedoutput/°F

Temperature effect, output ±0.002%ofreading/°F

MOUNTING DIMENSIONS

TYPICAL SYSTEM DIAGRAM

HoneywellIn-Line Amplifier

Output InputSerial Number

Power Supply

Customer SuppliedChart Recorder

Alarm PanelData Acquisition

ComputerPLC

MODEL X-Y FORCE

(Used with unamplified units only)

UVUV-10UBPU3WU2W

DV-05DA-05DV10

In-Line Amplifiers

Amplifier Universal In-Line Amplifiers

DIN rail Mount In-Line Amplifiers

Output

+/-5 VDC+/-10 VDC0 +/-5 VDC4-20mA (3 wire)4-20mA (2 wire)

0 +/- 5 VDC (3 wire)4-20mA (3 wire)0 +/- 10 VDC (3 wire)

2003.1 lb.L1 L2 L3 L4

UP DOWN

VALUE CLEAR CHAN TARE

ENTERSETUP EXIT

SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH7541 7558 7561-PSD

Display Units

* XX represents length in feet 100ft maximum** XX represents length in feet 20ft maximum

Mating Connectors & Cables

OR

064-LW13621 Mating connector7200-76-XX* Mating connector and six conductor cable (unamplified unit with sense leads but not shunt cal)7200-75-XX** Mating connector (MS - 5 pin) and four conductor cable (unamplified sensor without sense leads)7200-111-XX** Mating connector ( MS – 5 pin ) & 6 conductor cable for connection to 7541 7200-110-XX** Mating connector ( MS – 5 pin ) & 4 conductor cable for connection to 7541

7.0 DIA.

13/32 4 HOLESEQUALLY SPACED

6.25 DIA. B.C.

45

2-21/321.062

2-1/16 TYP.2.50 DIA.

BOTH ENDS 0.75

1/87/64 MAX.

1.0

RECEP.MS-3102E-14S-5P (2)

BRGBORE

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008836-1-EN IL50 GLO June 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Models 6443 X-Y Force Sensor

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureofthe product could result in personal injury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheach product.

Failure to comply with these instructions could result in death or serious injury.

NOTES1. Standardcalibrationfortension/compressionloadcellsisinten-

sion only.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Minigram Beam Load CellModel MBH

DESCRIPTIONModels MBH Minigram Beam Load Cells are engineered to

measure very low bending forces and still achieve an impressive

0.1% full scale non-linearity and hysteresis. Built-in overload

stops are incorporated to provide additional reliability. Miniature

dimensions allow easy unit integration into existing systems.

Model MBH uses foil gages and is available for load ranges from

150 grams to 10 pounds.

FEATURES• 150gto10lbrange

• Miniaturesize

• 0.1%linearity

• Smalldiameter

• Integralcable

• Calibratedincompressiononly

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model MBH

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges4 150, 250, 500, 1000 g; 5, 10 lb

Linearity (max.) ±0.1 % full scale

Hysteresis (max.) ±0.1 % full scale

Non-repeatability (max.) ±0.03 % full scale

Output (tolerance) 2 mV/V (nominal)

Operation Tension/compression1

Resolution Infinite

RANGE CODES

Range Codes Range

AL 150 g

AN 250 g

AP 500 g

AR 1000 g

AT 5 lb

AV 10 lb

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded foil

Excitation (calibration) 5 Vdc

Insulationresistance 5000 mOhm @ 50 Vdc

Bridge resistance 350 ohm

Zero balance ±5 % full scale

Electrical termination (std) Cable 1,83 m [5 ft]

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 400 % full scale or 20 lb, whichever is less2

Weight 50 g

Material Aluminum

WIRING CODES

Cable Unamplified

Red (+) excitation

Black (-) excitation

Green (-) output

White (+) output

MOUNTING DIMENSIONS

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -18 °C to 71 °C [0 °F to 160 °F]

Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]

Temperature, storage -73 °C to 93 °C [-100 °F to 200 °F]

Temperatureeffect,zero 0.005 % full scale/°F

Temperature effect, span 0.005 % full scale/°F

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load range 150, 250, 500, 1000 g; 5, 10 lb

Temperaturecompensation

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F

Internal amplifiers

2u.Unamplified,mV/Voutput

Electrical termination

6e.Integralcable:Teflon6d.MicrotecDR-4S-4Hfour-pin

Special calibration

9a. 10 point (5 up/5 down) 20 % increments @ 70 °F

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985 Douglas Drive North

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008668-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model MBH Minigram Beam Load Cell

TYPICAL SYSTEM DIAGRAM

NOTES

1. Positive in compression; calibrated in compression only.2. Allowable maximum loads – maximum load to be applied without

damage.3 3. Withoutdamage-loadingtothislevelwillnotcauseexcessivezero

shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

4. ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your orderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywell during the period of coverage, Honeywell will repair orreplace,atitsoption,withoutchargethoseitemsitfindsdefective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY

•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION

•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Minigram Beam Load CellModel MBL

DESCRIPTIONModels MBL Minigram Beam Load Cells are engineered to

measure very low bending forces and still achieve an impressive

0.1 % full scale non-linearity and hysteresis. Built-in overload

stops are incorporated to provide additional reliability. Miniature

dimensions allow easy unit integration into existing systems.

Model MBL uses semiconductor gages and is available for load

ranges from 25 to 1000 grams.

FEATURES• 25gto1000g

• Miniaturesize

• 0.1%linearity

• Smalldiameter

• Integralcable

• Calibratedincompressiononly

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model MBL

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges4 25, 50, 100, 150, 250, 500, 1000 g

Linearity (max.) ±0.1 % full scale

Hysteresis (max.) ±0.1 % full scale

Non-repeatability (max.) ±0.03 % full scale

Output (tolerance) 20 mV/V (nominal)

Operation Tension/compression1

Resolution Infinite

RANGE CODES

Range Codes Range

AH 25 g

AJ 50 g

AK 100 g

AL 150 g

AN 250 g

AP 500 g

AR 1000 g

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Bonded semiconductor

Excitation (calibration) 5 Vdc

Insulationresistance 5000 mOhm @ 50 Vdc

Bridge resistance 500 ohm

Zero balance ±5 % full scale

Electrical termination (std) Cable 1,83 m [5 ft]

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 400%FS2

Weight 50 g

Material Aluminum

WIRING CODES

Cable Unamplified

Red (+) excitation

Black (-) excitation

Green (-) output

White (+) output

MOUNTING DIMENSIONS

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -18 °C to 93 °C [0 °F to 200 °F]

Temperature, compensated 15 °C to 71 °C [60 °F to 160 °F]

Temperature, storage -73 °C to 93 °C [-100 °F to 200 °F]

Temperatureeffect,zero 0.015 % full scale/°F

Temperature effect, span 0.02 % full scale/°F

OPTION CODESMany range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load range 25, 50, 100, 150, 250, 500, 1000 g

Temperaturecompensation

1a. 60 °F to 160 °F1b. 30 °F to 130 °F1c. 0 °F to 185 °F

Internal amplifiers

2u.Unamplified,mV/Voutput

Electrical termination

6e.Integralcable:Teflon6d.MicrotecDR-4S-4Hfour-pin

Special calibration

9a. 10 point (5 up/5 down) 20 % increments @ 70 °F

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985 Douglas Drive North

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008667-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model MBL Minigram Beam Load Cell

TYPICAL SYSTEM DIAGRAM

NOTES

1. Positive in compression; calibrated in compression only.2. Allowable maximum loads – maximum load to be applied without

damage.3 3. Withoutdamage-loadingtothislevelwillnotcauseexcessivezero

shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths.

4. ThisunitcalibratedtoImperial(non-Metric)units.

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your orderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywell during the period of coverage, Honeywell will repair orreplace,atitsoption,withoutchargethoseitemsitfindsdefective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensing or call +1-815-235-6847Email inquiries to [email protected]

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Force Sensing Clevis PinModel LP

DESCRIPTIONModel LP load pins are designed to be installed where pins or

bolts are carrying a load. Applications which involve the use of

shackle pins, clevis pins and pully shafts are prime examples of

where force sensing clevis pins can provide accurate, real time

monitoring of load forces. The Model LP features welded stain-

less steel construction and is available with a standard PTIH-10-

6P connector or an optional submersible cable. These

rugged clevis pins provide excellent long term stability and reli-

able operation under severe operating conditions.

FEATURES• 2000lbto200000lbrange

• Upto1%accuracy

• Allweldedstainlesssteelconstruction

• Amplifiedoutputavailable

• Intrinsicallysafeavailable(2Noptiononly)8

• CEapproved9

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

2Honeywell•SensingandControl

Model LP

PERFORMANCE SPECIFICATIONS

Characteristic Measure

Load ranges10 2000,3000,5000,6000,10000,12500,20000,30000,50000,75000,100000,125000,150000,and200000lb

Linearity(max.) from±0.5%fullscale(consultfactory)

Hysteresis from±0.5%fullscale(consultfactory)

Non-repeatability ±0.15%fullscale

Tolerance on output 1 mV/V nominal

ENVIRONMENTAL SPECIFICATIONS

Characteristic Measure

Temperature, operating -54°Cto93°C[-65°Fto250°F]

Temperature, compensated 15°Cto54°C[60°Fto160°F]

Temperature effect, zero 0.003%fullscale/°F

Temperature effect, span 0.008%ofload/°F

ELECTRICAL SPECIFICATIONS

Characteristic Measure

Straingagetype Foil

Excitation(calibration) 10 Vdc

Bridge resistance 5000ohm

Electricaltermination(std) PTIH-10-6P

Matingconnector(notincl.) PT06A-10-6Sorequivalent(AA111)

MECHANICAL SPECIFICATIONS

Characteristic Measure

Maximum allowable load 200%FS1

Casematerial 17-4PHstainlesssteel

RANGE CODES

Range Code

Available ranges Range Code

Available ranges

DL 2000lb EN 30000lb

DN 3000lb EP 50000lb

DR 5000lb ER 75000lb

DS 6000 lb ET 100000 lb

DV 10000 lb FH 125000lb

DW 12500lb FJ 150000lb

EL 20000lb FL 200000lb

WIRING CODES

Connector Unamplified (Std.)

A (+)excitation

B (+)excitation

C (-)excitation

D (-)excitation

E (-)output

F (+)output

INSTALLATIONStandardusesforclevispinsincludetongueandyokeshackles

andtensionpulleys.Clevispinsarealsooftenidealforuseinweb

tensionapplications.Consultfactoryforwebtensionmeasurement

kitsfrom200lbto500000lb.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl3

Force Sensing Clevis Pin

INTERNAL AMPLIFIERS

Amplifier specifications

Voltage out-put: Option 2a

Voltage out-put: Option 2c

Voltage out-put: Option 2t

Current three-wire: Option 2j

Current two-wire: Option 2k

Intrinsically safe amp: Op-tion 2n (2N)***

Output signal 0Vto5V 0Vto5Vor±5V@45mA

0 V to 10 V or ±10V@45mA

4mAto20mA 4mAto20mA 4mAto20mA

Input power (voltage) ±15Vor26Vdcto32Vdc

11Vdcto28Vdc 15Vdcto28Vdc 22Vdcto32Vdc 15Vdcto 40Vdc

9 Vdc to 28Vdc

Input power (current) 45mA 40mA 40mA 65mA 4mAto28mA 4mAto24mA

Freq. resp (amp) 3000Hz 3000Hz 3000Hz 2500Hz 300Hz 2000Hz

Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db

Operating temp. -20°Fto185°F -20°Fto185°F -20°Fto185°F 0°Fto185°F 0°Fto185°F -20°Fto185°F

Reverse voltage protec-tion

Yes Yes Yes Yes Yes Yes

Short cir. protection Momentary Momentary Momentary Yes Yes Yes

Wiring code: connector (std)4

A(+)SupplyB Output commonCSupplyreturnD(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyB Output common**CSupplyreturn**D(+)OutputEShuntcal1FShuntcal2

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

A(+)SupplyBNoconnectionCNoconnectionD(+)OutputECasegroundFNoconnection

Wiring code: cable4,5,6 R(+)SupplyBl Output commonGSupplyreturnW(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl Output common*GSupplyreturn*W(+)OutputBShuntcal1BrShuntcal2

R(+)SupplyBl(+)OutputWCaseground

R(+)SupplyBl(+)OutputWCaseground

* Black and green wires are internally connected.**PinsBandCareinternallyconnected.***SeeourWebsiteforthemostup-to-dateinformationregardingintrinsicallysafeapprovals,ref.#008-0547-00.

TYPICAL SYSTEM DIAGRAM

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

4Honeywell•SensingandControl

Model LP

OPTION CODES

Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/TMsensor-ship for updated listings.

Load ranges 2k,3k,5k,6k,10k,12.5k,15k,20k,30k,50k,75k,100k,125k,150k,200klb

Temperature compensation

1a.60°Fto160°F1b.30°Fto130°F1c.0°Fto185°F1d.-20°Fto130°F1e.-20°Fto200°F1f.70°Fto250°F

1g.70°Fto325°F3

1i.-65°Fto250°F3

1j.0°Cto50°C1k.-20°Cto85°C1m.-25°Cto110°C

Internal amplifiers

2a.Four-wire0Vdcto5Vdcoutput2c.0Vdcto5Vdcoutput2j.4mAto20mA(three-wire)output2k.4mAto20mA(two-wire)output11

2n(2N)4mAto20mA(two-wire)intrinsicallysafe11

2t.0Vdcto10Vdc2u.Unamplified,mV/Voutput

Electrical amp enhancements

3a.Input/outputisolation2

3d.Remotebufferedshuntcalibration

Electrical termination

6a.BendixPTIH-10-6P(orequivalent)6-pin(max.250°F)6b.MSconnectorMS3102E-14S-6P(mateswithMS3106E-

14S-6S)(max.160°F)6f.Integralcable:PVC6g.Integralcable:Neoprene

6h.Integralcable:Silicone6i. Integral underwater cable6j.1/2-14conduitfittingwith5ftoffourconductorPVCcable6q.Moldedintegralcable:Polyurethane6v. Phoenix connector at end of cable15d.Connectoronendofcable

Shunt calibration

8a. Precision internal resistor3

Special calibration

9e.CEmark9a.10point(5up/5down)20%increments@70°F9b.20point(10up/10down)10%increments@70°F9c.ASTME-74calibration

Bridge resistance

12b.5000ohm(foil)

Zero and span adjustment

14a.Noaccesstozeroandspanadjustment

Special calibration

30a.Compressiononly(+)output30b.Tensionandcompression(+,-)output30c.Compressiononly(-)output

Shock and vibration

44a.Shockandvibrationresistance

Interfaces 53e.Signaturecalibration3

53t.TEDSIEEE1451.4module7

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Honeywell•SensingandControl5

Force Sensing Clevis Pin

MOUNTING DIMENSIONS

Capac-ity lb

A mm [in]**

B mm [in]

C mm [in]

D mm [in]

F mm [in]

G mm [in]

H mm [in]

J mm [in]

Key mm [in]

SRG* N mm [in]

2000,3000

12,7[0.500]

12,7[0.50]

19,05[0.75]

38,1[1.50]

101,09 [3.98]

6,35[0.25]

5,08[0.20]

6,35[0.25]

NA 11,89 [0.468]

0,99 [0.039]

5000,6000

19,05[0.750]

14,99[0.59]

25,4[1.00]

38,1[1.50]

113,79[4.48]

7,87[0.31]

5,08[0.20]

6,35[0.25]

3,96[0.156]

17,88[0.704]

1,17[0.046]

10000, 12500

25,4[1.00]

16[0.63] 25,4[1.00]

38,1[1.50]

120,4[4.74]

12,7[0.50]

5,08[0.20]

6,35[0.25]

5,56[0.219]

23,88[0.940]

1,17[0.046]

15000,20000

31,75[1.250]

20,57[0.81]

35,05[1.38]

50,8[2.00]

144,53[5.69]

16[0.63] 6,86 [0.27]

6,35[0.25]

5,56[0.219]

29,87[1.176]

1,42[0.056]

30000 38,1[1.50]

23,88[0.94]

41,40[1.63]

50,8[2.00]

157,48[6.20]

16[0.63] 6,86 [0.27]

6,35[0.25]

7,14[0.281]

35,71[1.406]

1,42[0.056]

Capac-ity lb

A mm [in]** B mm [in] C mm [in] D mm [in] F mm [in] G mm [in] H mm [in] J mm [in] Key mm [in]

50000 50,8[2.000] 25,4[1.00] 50,8[2.00] 38,1[1.50] 167,89[6.61] 19,05[0.75] 6,76[0.266] 9,65[0.38] 7,14[0.281]

75000 63,5[2.500] 31,75[1.25] 63,5[2.50] 50,8[2.00] 193,29[7.61] 19,05[0.75] 6,76[0.266] 12,7[0.50] 7,14[0.281]

100000 69,85[2.750] 37,34[1.47] 69,85[2.69] 50,8[2.00] 219,20[8.63] 25,4[1.00] 10,31[0.406] 12,7[0.50] 10,31[0.406]

125000 76,2[3.000] 36,58[1.44] 76,2[3.00] 50,8[2.00] 225,55[8.88] 25,4[1.00] 10,31[0.406] 16[0.63] 10,31[0.406]

150000 88,9[3.500] 44,45[1.75] 88,9[3.50] 50,8[2.00] 263,65[10.38] 31,75[1.25] 13,49[0.531] 16[0.63] 13,49[0.531]

200000 101,6[4.000] 57,15[2.25] 101,6[4.00] 50,8[2.00] 301,75[11.88] 31,75[1.25] 13,49[0.531] 19,05[0.75] 13,49[0.531]

*SRG-Snapringgroovediameter**Tolerance=+0.000in/-0.002in

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

SensingandControl

AutomationandControlSolutions

Honeywell

1985DouglasDriveNorth

GoldenValley,MN55422USA

+1-815-235-6847

www.honeywell.com/sensing

008669-1-EN IL50 GLO May 2008Copyright © 2008 Honeywell International Inc. All rights reserved.

Model LP Force Sensing Clevis Pin

Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your orderacknowledgementorconsultyourlocalsalesofficeforspecificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywell during the period of coverage, Honeywell will repair orreplace,atitsoption,withoutchargethoseitemsitfindsdefective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FormoreinformationaboutSensingandControlproducts,visitwww.honeywell.com/sensingorcall+1-815-235-6847Emailinquiriestoinfo.sc@honeywell.com

WARNINGPERSONAL INJURY•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.

Failure to comply with these instructions could result in death or serious injury.

WARNINGMISUSE OF DOCUMENTATION•Theinformationpresentedinthiscatalogueisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.

Failure to comply with these instructions could result in death or serious injury.

NOTES

1. Allowable maximum loads – Maximum load to be applied without damage.

2. Onlyavailablewithoption2bor2c.3. Notavailablewithamplifiedoption.4. Interconnectingshuntcal.1terminalwithshuntcal.2terminal

provides50%(unamplifiedunits),75%(4mAto20mAthree-wireunits)or80%(voltageamplifiedunits)offullscaleoutputforquickcalibration.Shuntcalibrationcomesstandardwithinternalamplifieroption2a,2b,2c,2tand2j.

5. O=Orange;Y=Yellow;B=Blue;Bl=Black;R=Red;Br=Brown;W=White;G=Green.Colorspecifyingcableandnumberorletterspecifying connector.

6. Nomatingconnectornecessaryforcableoption.7.ConsultfactoryforTEDSavailabilitywithamplifiedmodels.8. Range dependent; consult factory. Termination dependent; consult

factory.9. Internal amp and termination dependent; consult factory.10. ThisunitcalibratedtoImperial(non-Metric)units.11. 5000ohmbridgerequired.

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com