HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - … · • The circuit breaker remains...

12
ELECTRICAL SAFETY SOLUTIONS / HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - 3 kV DC RAIL VEHICLES S

Transcript of HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - … · • The circuit breaker remains...

Page 1: HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - … · • The circuit breaker remains closed with a reduced ‘’holding’’ current. To open the circuit breaker the holding

ELECTRICAL SAFETY SOLUTIONS /

HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - 3 kVDC RAIL VEHICLES

S

Page 2: HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - … · • The circuit breaker remains closed with a reduced ‘’holding’’ current. To open the circuit breaker the holding

HIGH-SPEED DC CIRCUIT BREAKERS, TYPE UR26, UR36 & UR40 - 3 KVDC2

APPLICATIONS

GENERAL INFORMATIONThe UR26, UR36 & UR40 are DC high-speed, current-limiting, circuit-breakers with natural cooling. They are trip free, single pole, bi-directional and equipped with electromagnetic blow-out, electric control circuits and direct over-current instantaneous release.With its simple design and high insulation level, the UR range offers a very high reliability as well as an exceptionally long lifetime.To guarantee a safe and optimized installation of its circuit-breakers in different environments, Sécheron offers a large range of standard and customized solutions. The circuit-breaker of the UR range can be delivered with an insulating housing, for indoor installation or, for outdoor use, in DC MODBOX® or in a polyester protective enclosure.

DC MODBOX® is a modular platform where the DC circuit-breaker is integrated alone or with other high and low voltage components (contactors, disconnectors, resistors, voltage and current sensors…) in a light and compact metal box. This way, rolling stock manufacturers can be supplied with a fully tested “Plug & Play” unit, easy to install and highly valuable for project management and logistics (refer to brochure SG580044BEN for more details).With its proven worldwide experience and acceptance, Sécheron’s circuit-breaker is the key product to guarantee the highest safety to rolling stock material and to the people operating or using it.

3 kVDC traction vehicles to protect propulsion and auxiliary equipment

High insulation voltage High rated short-circuit making and breaking capacity. Limited maximum arc voltage. Operational frequency C3. Alargenumberofdifferentoptionstomatchvariousapplicationrequirements Optional integrated ECO-Drive control module, to manage the closing

- holding sequences, and to save holding energy consumption and operational costs

Very low maintenance requirements. Proven design with worldwide experience and acceptance.

10 Voltage sensor AC, TMS

11 AC circuit breaker & earthing switch, MACS

12 Roof line disconnector, RS

Energy meter, REM13 Roof making switch, RS-M

15 Disconnector, XMS

14 Contactors & modules, BMS, SEC, HS

16 Key multiplier, KM

17 Door lock, DL

18 Master controller, MMC

19 Wheel flange lubrificator, GB-G

20

Trac

tion

Conv

erte

r

15/25 kVAC and 0.75/1.5/3.0 kVDC

DC

Link

Auxil

iary

Conv

erte

r

Train Roof Line

2

3

4

5

6

7

88

9

4

455

10

11

12

13

14

14

14

14

15

14

14

14

16

17 17 17

18

19

19

19

19

1

1 Pantograph, SPL

4 Surge arrester

5 Current sensor

6 Voltage sensor DC

7 DC circuit breaker, UR

8 Earthing switch, BTE03.04

Pantograph interlocking switch, BSV2 High voltage integrated system, MODBOX®9

Changeover switch, RS3

9 20

Roof makingswitch

Current sensor

Changeoverswitch

PantographSurge Arrester

Surge Arrester

Roof line disconnector

High voltageintegrated system DC

High voltageintegrated system AC

Earthing switch

Earthing switch

Energy meter

Mastercontroller

Wheel flangelubrificator

Pantograph interlocking switch

Key multiplier

Door lockContactors

DC Circuit breaker

Earthing switch

Contactors

Voltagesensor

Voltagesensor

Current sensor

AC circuit breaker

MAIN BENEFITSMAIN BENEFITS

Page 3: HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - … · • The circuit breaker remains closed with a reduced ‘’holding’’ current. To open the circuit breaker the holding

HIGH-SPEED DC CIRCUIT BREAKERS, TYPE UR26, UR36 & UR40 - 3 KVDC 3

MAIN FEATURES• Rated operational voltage 3’600 VDC

• Conventional free air thermal current: 2’300 A (UR26), 3’600 A (UR36) and 4’000 A (UR40)

• Electro-magnetic closing with electric holding • Five double contacts auxiliary switches • Pollution degree PD3• Insulation material according to EN45545-2:2013• Reference standards: EN/IEC 60077-1/3, IEC77, IEC 61373

IEC-60077

Id

Îd

Iss

0.63 Iss

Ut

ttm

I

tb

Îss

di/dt

T

Ûarc

Ue

/// OPENING TIME TI

Iss = Prospective sustained short-circuit currentÎss = Peak of IssId = Setting of maximum current releaseÎd = Cut off currentdi/dt = Initial current rate of riseT = Circuit time constantUe = Rated operational voltageÛarc = Peak of the arc voltageti = Opening timetb = Total break time

20t l

t l

[ms]18

[ms]

16

14

12

10

8

6

4

2

03.105 5 7 53 37106 107

di/dt [A/s]

UR26

UR36/40/46

10

8

6

4

2

03.105 5 7 53 37106 107

di/dt [A/s]

UR60/80

Relationship between opening time tl and the initial rate of rise of current di/dt for direct instantaneous over-current release.Example for a di/dt of 3x106 A/s:- for UR26: tl ~ 4.3 ms.

Note: for a shorter opening time on low di/dt, the “indirect release” (shunt trip) option can be used (refer to “Options” section page 5).

BREAKING CURRENT PARAMETERS

Page 4: HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - … · • The circuit breaker remains closed with a reduced ‘’holding’’ current. To open the circuit breaker the holding

HIGH-SPEED DC CIRCUIT BREAKERS, TYPE UR26, UR36 & UR40 - 3 KVDC4

DATA FOR PRODUCT SELECTION

LOW VOLTAGE CIRCUITControl circuitNominal voltage Un [Vdc] 24, 36, 48, 60, 64, 72, 110Range of voltage [0.7 - 1.25] Un

Nominal Closing power (2) Pc [W]/[s] 1’300/1Nominal Holding power for electrical holding (8) [W] 2.3Mechanical opening time (2) (3) to [ms] 15 - 30Mechanical closing time (2) (3) tc [ms] ~ 150

(2) At Un and Tamb = +20°C • (3) When signal is received by the coil.

Auxiliary contactsType of contacts Potential free (PF)Number of auxiliary contacts 5a + 5bRated voltage [VDC] 24 to 110Conventional thermal current Ith [A] 10Switching categories according to EN60947 [A] AC-15 230 VAC 1.0 A [A] DC-13 110 VDC 0.5 AMinimum let-through current at 24 Vdc (4) [mA] ≥ 10 (silver contacts) or 4 ≤ I < 10 (gold contacts)

(4) For a dry and clean environment.

Low voltage interface

Type of connection (5) Harting type Han® 32 EE(5) Refer to page 5 for mobile connector information.

OPERATING CONDITIONSInstallation Indoor or outdoor (6)

Altitude (7) [m] ≤ 1’400Working ambient temperature (8) Tamb [°C] - 25 to + 40°CRelative Humidity 95 % at 40°CPollution degree PD3Minimum mechanical durability N [Operations] 4x50’000 8x25’000 8x25’000

(6) Outdoor with optional enclosure or DC MODBOX® (refer to page 10 and page 11). (7) For altitude >1’400m, please contact Sécheron. (8) For -50°C ≤ Tamb < -25°C a special configuration of DC circuit-breaker can be delivered by Sécheron on request.

Symbol Unit UR26 UR36 UR40

MAIN HIGH VOLTAGE CIRCUITRated operational voltage UNe [VDC] 3’600 3’600 3’600Rated insulation voltage UNm [VDC] 4’800 4’800 4’800Conventional free air thermal current (1) Ith [A] 2’300 3’600 4’000Rated operational current Ie [A] 2’600 3’600 4’000Operational frequency - - -Power-frequency withstand voltage (50 Hz/1min) - Between open main contacts Ua [kV] 15 15 15- Between closed main contact and earth & control circuit [kV] 15 15 15- Between low voltage circuits and earth [kV] 2 2 2Ratedimpulsewithstandvoltage(1.2/50μs) Uimp [kVDC] 40 30 30Rated short-circuit making & breaking capacity / Time constant

ISS/T1 [kA]/[ms] 40/0 40/0 40/0ISS/T2 [kA]/[ms] 35/15 35/15 35/15ISS/T3 [kA]/[ms] 35/30 35/30 35/30ISS/T4 [kA]/[ms] 35/50 35/50 35/50

Direct over-current instantaneous release [kA] 1.4 - 2.7 2.0 - 5.0 2.0 - 5.0[kA] 2.0 - 5.0 4.0 - 10.0 4.0 - 10.0

Maximum arc voltage [kV] ≤ 8.0 ≤ 8.0 ≤ 8.0(1) At Tamb = +40°C and tested with high voltage connections according to standard IEC/EN 60943. •

Page 5: HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - … · • The circuit breaker remains closed with a reduced ‘’holding’’ current. To open the circuit breaker the holding

HIGH-SPEED DC CIRCUIT BREAKERS, TYPE UR26, UR36 & UR40 - 3 KVDC 5

(1) Approximate weight for standard cir-cuit-breakers with no option, including maintenance arc chute lifting mecha-nism.

UR26 UR36 UR40

Weights (1) [Kg] 164 181 185

(1)

(1)

(1)

B

A

490

1029

457

4x Ø

13.5

760

300 185

255

205

37095

100

3015

0

23

275 320 365

480480320320

676676320

320

700700724724

A

B

676676320

320

665

665

700700

450

450

215

215

676676

700700

320

320

320320480480

140275 320

490

4x Ø

13.5

9520

160

1029

645

300205

728

370

100

2755

185

9530

150

1035

760300 255 205

724

370

100

27

365457

(1) Heat sink on UR40 only

40 25

2550

25

4x Ø14

4x Ø14

40 25

2050

25

A

40 25

2550

25

4x Ø14

B

/// UR26

/// UR36/40

INFORMATION FOR PRODUCT INTEGRATION

D i m e n s i o n s w i t h o u t tolerances are indicative. All dimensions are in mm. The maximum allowed flatness deviation of the support frame is 0.5 mm.

HV connections for UR26

HV connections for UR36/40

MAIN DIMENSIONS

419 (81)

617 (82)238

A AB B

C78

4

320

A A

C B B B B

700

320

1035

1030

320C B B

1030

(1)

240 A A

C B B B B 700240

A A700

(1) At maximum short-circuit breaking capacity. For other installation condi-tions, contact Sécheron.

INSULATING DISTANCES

Note: For insulating distances to earth, contact Sécheron.

Minimum distances (1) [mm] to insulating wall

45 85

845

Page 6: HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - … · • The circuit breaker remains closed with a reduced ‘’holding’’ current. To open the circuit breaker the holding

HIGH-SPEED DC CIRCUIT BREAKERS, TYPE UR26, UR36 & UR40 - 3 KVDC6

LOW VOLTAGE CONTROL SCHEME

/// ELECTRIC HOLDING E-TYPE

• The circuit breaker remains closed with a reduced ‘’holding’’ current. To open the circuit breaker the holding current is cut-off.

• With E-type closing device, the circuit breaker cannot remain closed if the low voltage supply is lost.

Ie

~ 20%

100%

0

0

0,5 1 tc tc+1tc+0.5

t [s]

DBA

C

+

~ 5%

100%

0 0,5 1

t [s]

SV=

R1

E

F

G

B CA

DIe

E

B

C

A

D

SV=+

Rs

Maintien magnétique pour UR60/80(maintien électrique idem que UR26-36-40-46)

UR60/80

UR26/36/40/46

Rs

RpF1

F2 E2

E1

SV=

+

E1

E2

F1

F2

Customer scope

Ie

~ 20%

100%

0

0

0,5 1 tc tc+1tc+0.5

t [s]

DBA

C

+

~ 5%

100%

0 0,5 1

t [s]

SV=

R1

E

F

G

B CA

DIe

E

B

C

A

D

SV=+

Rs

Maintien magnétique pour UR60/80(maintien électrique idem que UR26-36-40-46)

UR60/80

UR26/36/40/46

Rs

RpF1

F2 E2

E1

SV=

+

E1

E2

F1

F2

Sécheron scope

F, G : control contactsR1 : holding resistorS : automatic circuit breaker

Ie

~ 20%

100%

0

0

0,5 1 tc tc+1tc+0.5

t [s]

DBA

C

+

~ 5%

100%

0 0,5 1

t [s]

SV=

R1

E

F

G

B CA

DIe

E

B

C

A

D

SV=+

Rs

Maintien magnétique pour UR60/80(maintien électrique idem que UR26-36-40-46)

UR60/80

UR26/40/46

Rs

RpF1

F2 E2

E1

SV=

+

E1

E2

F1

F2

Rs

RpF1

F2 E2

E1

SV=

+

UR26/40/46/60/80

RUR

/// TYPICAL VALUE FOR CLOSING COILS

Note: for components selection, the fol-lowing criteria shall apply:

Unom = RxInom for Tamb = +20°C Umin = RxImin for Tamb = - 5°C Umax = RxImax for Tamb = +40°C (R = Resistance)

Coil characteristics

Closing pulse 0.5 to 1s holding E-type

Unom Inom Imin E Imin M Imax R1nom Inom Imin Imax

[VDC] [A] [A] [A] [A] [Ω] [A] [A] [A]

24 41.7 22.5 25 70.9 11.4 2.0 1.4 2.5

36 32.7 17.7 19.6 55.6 25 1.4 0.1 1.7

48 20.9 11.3 12.5 35.4 45.7 1.0 0.7 1.3

64 17.6 9.5 10.6 29.9 79.4 0.8 0.5 1.0

72 16.4 8.8 9.8 27.8 100 0.7 0.5 0.9

110 11.7 6.3 7.0 19.9 210 0.5 0.4 0.6

Note: The duration of the closing pulse (E-type) as well as the opening pulse should be 0.5 - 1 s.

Page 7: HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - … · • The circuit breaker remains closed with a reduced ‘’holding’’ current. To open the circuit breaker the holding

HIGH-SPEED DC CIRCUIT BREAKERS, TYPE UR26, UR36 & UR40 - 3 KVDC 7

MOBILE CONNECTOR

OPTIONS (SUBJECT TO ADDITIONAL COSTS)

Auxiliary switchesControl voltage

Fixedconnector

type

Mobile connector (without cable)

Number of pinCablegland

Sécheron’snumber Connector

Device Number Type Size2.5 mm²

Size1.0 mm²

UR26/36/40 5a+5b PF 36, 48, 64, 72, 110 VDC

Harting HAN® 32 EE

2 30 M32 SG104063R10100

UR26/36/40 5a+5b PF 24 VDCHarting

HAN® 32 EE4 28 M32 SG104063R40100

The indirect release enables to shorten the breaker’s opening time tI down to about 4 ms, whatever the dl/dt conditions (see graph page 2), when required by specific applications.

The indirect release BI 24 is triggered by the control unit type CID-3 ( not included with the circuit-breaker - to be ordered separately - refer to CID3 brochure SG101783B...).

INDIRECT RELEASE/// BI 24

HARTING TYPE HAN® 32 EE

11 9

12 8

7 5 3 1

4

15

16

1319

20 10 6 21418

17

21

22

23

24(1)

(1)

(1) Double cable only for 24 VDC control voltage.

LOW VOLTAGE WIRING DIAGRAMS FOR HARTING TYPE HAN®32 EE CONNECTOR (STANDARD)

II>(WI)

a

b

a

b

(I>) (WI)a b a bHARTING

Brochure Brochure HARTINGHARTINGHARTING

Circuit breaker main contact

II>(WI)

a

b

a

b

(I>) (WI)a b a bHARTING

Brochure Brochure HARTINGHARTINGHARTING

Circuit breaker closing coil

II>(WI)

a

b

a

b

(I>) (WI)a b a bHARTING

Brochure Brochure HARTINGHARTINGHARTING

Low voltage connector interface (male pin)

II>(WI)

a

b

a

b

(I>) (WI)a b a bHARTING

Brochure Brochure HARTINGHARTINGHARTING

1a+1b - Switch PF

Legend of the schemes:

Page 8: HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - … · • The circuit breaker remains closed with a reduced ‘’holding’’ current. To open the circuit breaker the holding

HIGH-SPEED DC CIRCUIT BREAKERS, TYPE UR26, UR36 & UR40 - 3 KVDC8

Note:- Available for UR26/36/40/46- Available for closing device

with E-type holding

MAIN BENEFITSMAIN BENEFITS

ECO-DRIVE INTEGRATED CONTROL MODULE

ECO-Drive

Note:- Available for UR26/36/40- Available for closing device

with E-type holding

/// LOW VOLTAGE WIRING DIAGRAM

20

4

3

C

D

18 16 14

19 17

2628

2527

22

21

15 13

12 10 8 6

11 9 7 5

4 2

3 1

Vbat P

Vbat N

ORDP

ORDN

k0

Un

UEF

k1

+

+

-

-

Harting connector

Sécheron’s scope

Customer’s scope

The UR breaker together with the ECO-Drive is fully compliant for electromagnetic compatibility with EN 50121-3-2 and with EN 50155: § 5.1.1.2 short (10 ms) interruptions class S2 and § 5.1.3: voltage dips / variation (at 0.6 Un during 100 ms) class C1.

ECO-Drive is a compact control module integrated with UR circuit breakers, to manage closing-holding sequences with electric control. ECO-Drive is set on the UR breaker ’s closing device.

UR26/36/40 breakers need no more additional hardware to manage the closing-holding sequences

Reduction of the overall space necessary to operate the circuit-breaker Reduction of overall installation costs of the DC circuit-breakers Reduction of holding power consumption and operational costs versus conventional

holding variant Reduction of the risks of damaging the closing coil during commissioning and service

operations.

Page 9: HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - … · • The circuit breaker remains closed with a reduced ‘’holding’’ current. To open the circuit breaker the holding

HIGH-SPEED DC CIRCUIT BREAKERS, TYPE UR26, UR36 & UR40 - 3 KVDC 9

Sécheron proposes 3 different concepts to integrate the UR26/36/40 circuit-breakers in vehicles:• Complete Plug & Play Roof-mounted polyester enclosure, in which

the DC circuit-breaker is installed, and which offers an IP54 protection index. It is intended for EMUs and trains outdoor roof mounting (including high speed trains).

• Insulation housing with protection index IP00, delivered as an option separately from the breaker. It enables the car-builder to build its own metal enclosure and/or container with reduced dimensions, in which the DC circuit-breaker with its insulation housing will be installed. This type is mostly used for locomotives and trains.

• Complete Plug & Play metal enclosure (DC MODBOX® program), in which the DC circuit-breaker is set with other functions, such as current & voltage measurements. DC MODBOX® offers an IP56 protection index for outdoor roof or underframe mounting. This type is mostly used for trains and high-speed trains, as well as for applications with severe operational environments (cold and icy, dusty or sandy environment).

CONCEPTS FOR INTEGRATION ON VEHICLES

/// PLUG & PLAY ROOF-MOUNTED POLYESTER ENCLOSURE

Valid for UR26Enclosure material Insulation materialEnclosure colour Blue grey RAL 7031Enclosure thickness 6 mmProtection index IP IP54Opening of the box cover On low voltage connector sideMaximum breaking capacity Available on requestInsulation distance around the enclo-sure Available on request

High voltage cable interface 1 cable plate with 4 cable glands M32x1.5

Low voltage cable interface Harting HAN® 32 EE connector on enclosure

This enclosure can be directly mounted on the vehicle’s roof.

Note: plate is located on LV connector side.

ECO-DRIVE INTEGRATED CONTROL MODULE /// CONTROL CIRCUIT TECHNICAL DATA

Control circuit

Nominal voltage (electric holding only) (1) UN/UEF [VDC] 24, 36, 48, 64, 72, 110

Range of voltage [ 0.7 - 1.25 ] Un

Idle (standby) power [W] < 1.6

Nominal closing power (2) Pc [W]/[s] 1’300/0.5

Nominal holding power for electric holding (2) [W] < 8

Nominal opening power for electric holding (2) [W] < 1.6

Mechanical opening time on opening order (3) [ms] 15-30

Mechanical closing time on closing order (2)(3) Tc [ms] ~150

(1) Control voltage UEF and supply voltage Un can be different

(2) At Un and Tamb = +20°C(3) Starting when the signal is received

by the coil

UR26-64 TCP Roof mounting ( IP 54)

496

9001508

Page 10: HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - … · • The circuit breaker remains closed with a reduced ‘’holding’’ current. To open the circuit breaker the holding

HIGH-SPEED DC CIRCUIT BREAKERS, TYPE UR26, UR36 & UR40 - 3 KVDC10

This housing is designed to minimize the necessary i n s u l a t i o n c l e a r a n c e distances against earth, when the circuit-breaker is integrated in the car builder’s own metal enclosure.

FOR HORIZONTAL UNDERFRAME MOUNTING

FOR VERTICAL INDOOR MOUNTING

Valid for UR26Enclosure material Insulation materialEnclosure colour Beige RAL 1013Enclosure thickness 4 mmProtection Inde IP IP00Opening of the box Knurled knobsMaximum breaking capacity Available on requestInsulation distance around the enclo-sure

Available on request

Interface for high voltage cables Enclosure opening for cable connection on circuit-breaker

Interface for low voltage cable Direct connection on circuit-breaker’s connector

Valid for UR26/36/40Enclosure material Insulation materialEnclosure colour Beige RAL 7016Enclosure thickness 4 mmProtection Index IP IP00Opening of the box Knurled knobsMaximum breaking capacity available on request

Available on request

Insulation distance around the enclosure Available on request

Interface for high voltage cable Enclosure opening for cable connection on circuit-breaker

Interface for low voltage cable Direct connection on circuit-breaker’s connect

UR26-64 TCSUnderframe mounting(IP 00)

900

1767

545

525

977

998

500 816

1524

1500

770

470

1500

770

470

The purpose of this housing is to minimize the necessary i n s u l a t i o n c l e a r a n c e distances against earth, when the circuit-breaker is integrated in the car builder’s own meta l enc losure/container.

/// INSULATION HOUSINGSThe insulation housings have to be ordered additionally to the DC circuit-breaker (see page 12).

UR26/36/40-64Indoor mounting (IP00)

503800

1160

Page 11: HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - … · • The circuit breaker remains closed with a reduced ‘’holding’’ current. To open the circuit breaker the holding

HIGH-SPEED DC CIRCUIT BREAKERS, TYPE UR26, UR36 & UR40 - 3 KVDC 11

/// DC MODBOX®

To evaluate DC MODBOX® solution that best suits your project, please contact Sécheron.

DC MODBOX® is a compact metal clad, “plug and play’’, project-based solution, featuring several high voltage DC components located around the DC circuit-breaker.Built on a standard platform of rolling-stock-dedicated aluminium enclosure and standard proven high voltage DC components, DC MODBOX® can be, to a certain extent, adapted to the application requirements. Typically electric schemes, integrated components, as well as both high- and low-voltage interfaces can be customized.

With its limited height (535 mm) and a shape designed to match aerodynamic constraints, DC MODBOX® bring efficient solutions to solve co nstraints related to roof space, insulation and speed. Moreover it allows the high voltage DC components to operate protected from the most severe environmental conditions. DC MODBOX® simplifies project management, logistics, and installation tasks for the car builder.

RS : Roof switchMACS : Main AC switchAC VCB : AC vacuum circuit-breaker (MACS)ES : Earthing switch (MACS) SA : Surge arester I mes : Current measurement Umes : Voltage measurement Rpc : Pre-charging resistorUR : High speed DC circuit breaker BTE : Earthing switchPCC : Pre-charging contactorLC : Line contactor BMS or SEC

DC MODBOX®

UR

ES

RSRpcPCC

LC 1

RpcPCC

LC 2

Um

es

SA1

Imes

1.5kVDC or 3kVDC

Pantograph

To tractionequipments

RS : Roof switchMACS : Main AC switchAC VCB : AC vacuum circuit-breaker (MACS)ES : Earthing switch (MACS) SA : Surge arester I mes : Current measurement Umes : Voltage measurement Rpc : Pre-charging resistorUR : High speed DC circuit breaker BTE : Earthing switchPCC : Pre-charging contactorLC : Line contactor BMS or SEC

DC MODBOX®

UR

ES

RSRpcPCC

LC 1

RpcPCC

LC 2

Um

es

SA1

Imes

1.5kVDC or 3kVDC

Pantograph

To tractionequipments

Functional scope

Page 12: HIGH-SPEED DC CIRCUIT BREAKERS Type UR26, UR36 & UR40 - … · • The circuit breaker remains closed with a reduced ‘’holding’’ current. To open the circuit breaker the holding

Copyright© 2019 Sécheron SA

This document is not contractual and contains information corresponding to the level of technology at the date of printing. Sécheron reserves the right to modify and/or improve the product, whose characteristics are described in these documents, as required by new technology at any time. It is the purchaser’s responsibility to inform himself, no matter what the circumstances, of the product’s maintenance conditions and requirements. Sécheron reserves all rights, especially those arising from our “General Delivery Conditions”.

SG

10

53

06

BE

N_A

04

-01

.19

Sécheron SA Rue du Pré-Bouvier 251242 Satigny - GenevaCH-Switzerland

Tel: +41 22 739 41 11Fax: +41 22 739 48 [email protected]

Pla

ce a

nd d

ate:

N

ame:

S

igna

ture

:

DESIGNATION CODELine Description Designation Standard Options Customer’s

choice10 Product type UR UR UR11 Conventional free air thermal current 2’300 A 26

3’600 A 364’000 A 40

12 Rated operational voltage 3’600 V 64 6413 Application Rolling stock T T14 Mounting position Vertical D

Horizontal C15 Breaker execution Vertical indoor mounting (1) Ø

Horizontal roof mounting with polyester enclosure P Horizontal roof mounting with polyester enclosure (2) S

16 Nominal Control voltage 24 VDC A36 VDC B48 VDC C64 VDC G72 VDC D

110 VDC E17 Varistor in coil (3) No Ø

Yes (battery voltage) 118 Direct over-current release (bi-directional)

For UR26 1.4 - 2.7 kA AFor UR26/36/40 2.0 - 5.0 kA BFor UR36/40 4.0- 10.0 kA G

19 Indirect release No ØBI24 1

20 Auxiliary contacts (4) 5a + 5b - (switch PF) - Silver type A5a + 5b - (switch CO) - Gold type C

21 LV connector type on circuit breakerHarting type HAN® 32 EE C

22 Eco-Drive control module No ØYes 4

23 Digit for Sécheron internal purpose UR 26 V UR 36/40 A

(1) For execution ordered with additional insulation housing, the housing must be ordered separately (section below) • (2) The insulation housing for the breaker’s execution UR26-64TCS must be ordered separately (section below) • (3) In case control type “ECO-Drive” is selected (line 22), select “No” for Varistor on Coil (line 17)• (4) Based on the selected breaker’s configuration, the number of available auxiliary switches might be reduced•

DESIGNATION CODE FOR ORDERING• Be sure to establish the designation code from our latest version of the brochure by downloading it from our

website “www.secheron.com”.• Be careful to write down the complete alphanumerical designation code with 17 characters when placing your order.• The customer shall write down the setting of maximum current release value (Id) in its order form.• For technical reasons some variants and options indicated in the designation code might not be combined.• The bold part of this designation code defines the device type, and the complete designation defines the

identification number of the product, as displayed on the identification plate attached to the product.

Example of customer’s choice: UR 26 64 T D Ø E Ø B Ø A C Ø V

Line: 11 11 12 13 14 15 16 17 18 19 20 21 22 23

Material to be ordered separetely:-Insulation housing (refer to page 10):Insulation housing for vertical indoor mounting: SG104420R00002 Insulation housing for UR26-64TCS: SG102006R. . . . .

-Low voltage mobile connector (refer to page 7): None Harting Han® 32 EE SG104063R10100 Harting Han® 32 EE SG104063R40100

Value of the setting of maximum current release value (Id): . . . . . . . . . . . . . . [A]