High Resolution ICP-MS THERMAL IONISATION MASS...

2
Evolution HR Gas Analysis MS Nu Plasma II Multi-Collector ICP-MS Nu Plasma 1700 Multi-Collector ICP-MS Nu TIMS Thermal Ionisation MS Attom High Resolution ICP-MS Astrum Glow Discharge MS Noblesse Noble Gas MS Panorama HR Stable Isotope Ratio MS Horizon Stable Isotope Ratio MS Perspective Stable Isotope Ratio MS Nu Instruments Limited, Unit 74, Clywedog Road South, Wrexham, LL13 9XS UK. Tel: +44 (0)1978 661304 Fax: +44 (0)1978 664301 Email: [email protected] Email: [email protected] www.nu-ins.com 14172 BR04.1 THERMAL IONISATION MASS SPECTROMETER

Transcript of High Resolution ICP-MS THERMAL IONISATION MASS...

Page 1: High Resolution ICP-MS THERMAL IONISATION MASS …i.pupiq.net/a/c/c/26/26/1791795/Nu_TIMS_brozura.pdf · 2015. 8. 31. · Nu TIMS Nu TIMS Features † Completely new optimised astigmatic

EvolutionHR Gas Analysis MS

Nu Plasma IIMulti-Collector ICP-MS

Nu Plasma 1700 Multi-Collector ICP-MS

Nu TIMSThermal Ionisation MS

AttomHigh Resolution ICP-MS

AstrumGlow Discharge MS

NoblesseNoble Gas MS

PanoramaHR Stable Isotope Ratio MS

HorizonStable Isotope Ratio MS

PerspectiveStable Isotope Ratio MS

Nu Instruments Limited, Unit 74, Clywedog Road South,Wrexham, LL13 9XS UK.

Tel: +44 (0)1978 661304 Fax: +44 (0)1978 664301Email: [email protected]: [email protected]

www.nu-ins.com

1417

2

BR04.1

THERMAL IONISATIONMASS SPECTROMETER

Page 2: High Resolution ICP-MS THERMAL IONISATION MASS …i.pupiq.net/a/c/c/26/26/1791795/Nu_TIMS_brozura.pdf · 2015. 8. 31. · Nu TIMS Nu TIMS Features † Completely new optimised astigmatic

SourceThe source has been designed for ease of use and robustness.Constructed out of a single piece of stainless steel, the sample turret isdesigned for minimal trapped volume. It holds 20 single or doublefilaments. Position of the turret is controlled by visible light sensingtechnology. Individual filament assemblies are completely enclosed toremove the possibility of cross contamination. An optional degas benchcan be supplied to enable rapid outgassing of filaments in batches of 40.

Zoom Optics During a multi-dynamic acquisition the mass spectrometerjumps the magnet through a series of magnet positions on different sets of Faraday buckets. With conventionalcollector systems, compromised positions need to be setup to allow for multiple cycle measurements. The NuTIMS Zoom Optics allows instantaneous mass dispersionswitching, providing perfect peak alignment of all peaks inall configurations for multi-dynamic acquisition of five cyclesor more.

The traces show peak coincidence with and withoutZoom Optics on cycle five of a five cycle multi-dynamicroutine.

In both cases, the instrument was set up for peakcoincidence for the middle (3rd) cycle of the run. With the Zoom Optics employed, perfect coincidence is achieved for every cycle (although only the last one isshown), whilst without it in operation, the peaks wouldgradually lose coincidence.

Cycle 5 Without Zoom Optics

With Zoom Optics

Thermal ionisation mass spectrometry (TIMS) is a techniquethat precisely and accurately measures elemental isotopic ratios.

The Nu TIMS has been developed using our field-provenvariable dispersion multi-collector technology to improve theversatility and overall performance of this long establishedanalytical technique. It combines design advances in filamentassembly, ion optics and electronics control with ease of useand high precision. The Nu TIMS utilises our unique, patentedZoom lens system to ensure perfect peak alignment withoutthe requirement of moving detectors. The optional ion-counting mini Daly, capable of precise measurement of smallsamples and low abundance isotopes, provides the ultimatein stability, linearity and dynamic range

Nu TIMS

Nu TIMS Features• Completely new optimised astigmatic ion

optic arrangement with fully laminated 30cm radius magnet

• All stainless steel construction with rapidpump down for high throughput

• Independent electrostatic vertical andhorizontal focussing

• Turret constructed from a single piece ofstainless steel to minimise trappedvolumes

• Single and dual filament configuration

• Enclosed filament assembly designed toremove any possibility for crosscontamination

• Optional degas bench for rapid outgassingof filaments in batches of up to 40

• Patented Zoom Optics for perfect peakalignment and no moving parts

• Proven Faraday design with active innersurface and ultra-long lifetime

• User configurable detector array withoptional ion-counting systems

• Full size ion-counting electron multiplierswith proven performance and long lifetime

• Optional new mini Daly

• High abundance filter option

• Complete dry pumping system

• Extra bypass valve to overcome deadspace“trapped” volume between defining slitand LOS valve

• Easily dismountable lens stack andextraction lens plate for simple disassemblyand cleaning

• Modern comprehensive software suite.Data can be exported for analysis usingNICE, MS Excel, or to user configurableVB code via inter process communication

• Positive and negative mode with O2 bleed

• 55V dynamic range preamplifiers