HEAT PUMP 42QHA012VS 42QHA018VS 42QHA024VS ... - Carrier · The cover protects the valves against...

2
42QHA/38QHA Inverter High Wall Unit Notes: 1. T1 conditions: Indoor Air Temperatures °27C (DB) / °19C (WB) and Outdoor Air Temperatures °35C (DB) / °24C (WB) 2. T3 conditions: Indoor Air Temperatures °29C (DB) / °19C (WB) and Outdoor Air Temperatures °46C (DB) / °24C (WB) © Carrier Corporation 2018 Indoor Unit Unit Size TR BTU/h kW BTU/h kW Watts V-Ph-Hz Watts Watts Watts Btu/W-h Btu/W-h w/w mm Kg. °C V-Ph-Hz mts mts mm² / qty Cooling Cooling Heating Heating Rated Capacity at T1 Rated Capacity at T3 Rated Capacity Power Supply Total System Power Input at T1 Cooling Cooling Heating Cooling Cooling Total System Power Input at T3 Total System Power Input EER at T1 EER at T3 COP Air Filter Type Air Flow Rate (High/ Medium/ Low Speed) Indoor Noise Level (High/ Medium/ Low Speed) Net / Gross Weight Dimensions (W x D x H) Pipe Connection Size Liquid Suction Drain Outdoor Unit Power Supply Compressor Type Refrigerant Refrigerant Pipe (Max Length) Vertical + Horizontal Vertical (OU & IU) Recommended Wire Size/No. of Wires for Power Supply to Outdoor Unit * Recommended Wire Size/No. of Wires for Control from Indoor to Outdoor Unit * Dimensions (W x D x H) Net Weight Outdoor Air Temperature Operation (Cooling / Heating) Unit 870 1,080 950 13.75 9.80 3.65 356 / 280 / 230 41 / 37 / 33 8.7 / 11.1 802 x 189 x 297 25 10 1.5 / 3 1.5 / 4 1/4" 1/2" 800 x 333 x 554 37.3 / 39.9 30 20 2.5 / 3 1.5 / 4 845 x 363 x 702 41.4 / 44.6 30 20 2.5 / 3 1.5 / 4 946 x 410 x 810 59.6 / 65.4 50 25 2.5 / 3 1.5 / 4 946 x 410 x 810 64.1 / 69.3 3/8" 5/8" CFM dBA Kg mm inch inch inch 5/8" 220-240V- 50/60Hz, 1Ph DC Inverter Rotary R410a -1060/ -1524 Washable air filter HEAT PUMP 42QHA012VS 1.0 12000 3.51 10600 3.09 3,500 1,300 1,630 1,390 13.85 10.05 3.90 685 / 535 / 485 49 / 43 / 41 13.5 / 17.1 1080 x 226 x 335 42QHA018VS 1.5 18,000 5.25 16,400 4.80 5,450 1,570 1,970 2,100 14.00 9.75 3.60 685 / 540 / 485 49 / 45 / 41 13.8 / 17.4 1080 x 226 x 335 42QHA024VS 2.0 22,000 6.45 19,200 5.61 7,600 2160 2605 2100 12.50 8.85 3.95 765 / 645 / 575 51 / 48 / 45 20 / 25.9 1259 x282 x362 42QHA030VS 2.5 27000 7.90 23,200 6.80 8,300 38QHA012VS 38QHA018VS 38QHA024VS 38QHA030VS Unit HEAT PUMP 220-240V- 50/60Hz, 1Ph

Transcript of HEAT PUMP 42QHA012VS 42QHA018VS 42QHA024VS ... - Carrier · The cover protects the valves against...

Page 1: HEAT PUMP 42QHA012VS 42QHA018VS 42QHA024VS ... - Carrier · The cover protects the valves against impact during transportation. Furthermore, it also prevents the condensed water on

42QHA/38QHAInverter High Wall Unit

Notes:

1. T1 conditions: Indoor Air Temperatures °27C (DB) / °19C (WB) and Outdoor Air Temperatures °35C (DB) / °24C (WB)

2. T3 conditions: Indoor Air Temperatures °29C (DB) / °19C (WB) and Outdoor Air Temperatures °46C (DB) / °24C (WB)

© Carrier Corporation 2018

Indoor Unit

Unit Size TR

BTU/h

kW

BTU/h

kW

Watts

V-Ph-Hz

Watts

Watts

Watts

Btu/W-h

Btu/W-h

w/w

mm

Kg.

°C

V-Ph-Hz

mts

mts

mm² / qty

Cooling

Cooling

Heating

Heating

Rated Capacity at T1

Rated Capacity at T3

Rated Capacity

Power Supply

Total System Power Input at T1 Cooling

Cooling

Heating

Cooling

Cooling

Total System Power Input at T3

Total System Power Input

EER at T1

EER at T3

COP

Air Filter Type

Air Flow Rate (High/ Medium/ Low Speed)

Indoor Noise Level (High/ Medium/ Low Speed)

Net / Gross Weight

Dimensions (W x D x H)

Pipe Connection Size

Liquid

Suction

Drain

Outdoor Unit

Power Supply

Compressor Type

Refrigerant

Refrigerant Pipe (Max Length)

Vertical + Horizontal

Vertical (OU & IU)

Recommended Wire Size/No. of Wires forPower Supply to Outdoor Unit *

Recommended Wire Size/No. of Wires forControl from Indoor to Outdoor Unit *

Dimensions (W x D x H)

Net Weight

Outdoor Air Temperature Operation (Cooling / Heating)

Unit

870

1,080

950

13.75

9.80

3.65

356 / 280 / 230

41 / 37 / 33

8.7 / 11.1

802 x 189 x 297

25

10

1.5 / 3

1.5 / 4

1/4"

1/2"

800 x 333 x 554

37.3 / 39.9

30

20

2.5 / 3

1.5 / 4

845 x 363 x 702

41.4 / 44.6

30

20

2.5 / 3

1.5 / 4

946 x 410 x 810

59.6 / 65.4

50

25

2.5 / 3

1.5 / 4

946 x 410 x 810

64.1 / 69.3

3/8"

5/8"

CFM

dBA

Kg

mm

inch

inch

inch 5/8"

220-240V- 50/60Hz, 1Ph

DC Inverter Rotary

R410a

-10~ 60/ -15~24

Washable air filter

HEAT PUMP

42QHA012VS

1.0

12000

3.51

10600

3.09

3,500

1,300

1,630

1,390

13.85

10.05

3.90

685 / 535 / 485

49 / 43 / 41

13.5 / 17.1

1080 x 226 x 335

42QHA018VS

1.5

18,000

5.25

16,400

4.80

5,450

1,570

1,970

2,100

14.00

9.75

3.60

685 / 540 / 485

49 / 45 / 41

13.8 / 17.4

1080 x 226 x 335

42QHA024VS

2.0

22,000

6.45

19,200

5.61

7,600

2160

2605

2100

12.50

8.85

3.95

765 / 645 / 575

51 / 48 / 45

20 / 25.9

1259 x282 x362

42QHA030VS

2.5

27000

7.90

23,200

6.80

8,300

38QHA012VS 38QHA018VS 38QHA024VS 38QHA030VS

UnitHEAT PUMP

220-240V- 50/60Hz, 1Ph

Page 2: HEAT PUMP 42QHA012VS 42QHA018VS 42QHA024VS ... - Carrier · The cover protects the valves against impact during transportation. Furthermore, it also prevents the condensed water on

Advanced tropical inverter compressor can achieve high efficiency under high load condition.

New designed refrigerant pipe  radiator utilize low temp. refrigerant to cool the E-box efficiently, which can improve cooling performance at high ambient temperature.

Tropical inverter compressor Auto-cooling system

The upgraded DC motor power system of the inverter model forms a full DC frequency conversion system and dramatically reduces power consumption.

DC inverter compressor can operate faster and is more powerful, allowing it to cool much faster than conventional air conditioners.

With anti-rush coating, the cabinet is well protected from the elements.

Anti-rust cabinet

The indoor unit will show error code “EC” and stop automatically when refrigerant leakage is detected. This function can protect the compressor from being damaged.

Refrigerant leakage detection

The cover protects the valves against impact during transportation. Furthermore, it also prevents the condensed water on the valve from griping.

Valve protection cover

Follow me function for smart control of comfortable temperature when you stay close to the remote control. With this technology, an efficient temperature sensor is built in the remote control to sense your location and to make it feel like the air conditioner is following you.

Follow me function

Full Direct Current (DC) motorUltra low power consumption

Indoor fan DC motor Outdoor fan DC motor

refrigerant pipe radiator

From

the

cond

ense

r

DC inverter compressor

High efficiency motorfor wide operating voltage

High reliability material to withstand high pressure

Combines three filters from eight different types including cold catalyst filter, vitamin C filter, multifunction filter to meet various needs simultaneously and improve internal air quality (IAQ).

Compound filter

In the event of any abnormal operation or parts failure, the unit will shut off automatically to protect the system. Meanwhile it will indicate a protection or error code indicating a need for service.

Self-diagnostic function

The smart air flow function allows for optimum distribution of cooled air across the entire room.

Both left and right sides of the indoor unit are possible for outstretch of connective piping and drainage hose.

Smart air flow2 ways piping connection

DCI

DC

Fast cooling