(Hazardous Materials and Risk Assessment) Initial Survey : Noel Arnold & Associates : 24 - Apr - 2008 Parsons Brinckerhoff : 09 - Nov - 2016 School : Condobolin High School (8346) Asbestos Register Region : Western NSW State Electorate : Barwon Local Government Area : Lachlan Reviewed By : Register Issue Date : Wednesday, 18 Sep 2019 Page 1 of 25 8346 - Condobolin High School

Transcript of (Hazardous Materials and Risk Assessment) fileMaterial Description Extent Location Reference...

(Hazardous Materials and Risk Assessment)

Initial Survey : Noel Arnold & Associates : 24 - Apr - 2008

Parsons Brinckerhoff : 09 - Nov - 2016

School : Condobolin High School (8346)

Asbestos Register

Region : Western NSW

State Electorate : Barwon

Local Government Area : Lachlan

Reviewed By :

Register Issue Date : Wednesday, 18 Sep 2019 Page 1 of 258346 - Condobolin High School

Register Issue Date : Wednesday, 18 Sep 2019 Page 2 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00A - General Learning/Art - 1966 - Brick/Block

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids - Sub Structure

No Asbestos Found

Interior

B00A - R0001 - Music Store (10.05 m2)

No Asbestos

B00A - R0002 - General Learning Space (52.82 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0003 - General Learning Space (53.19 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0004 - Cleaning Store - Distributed (2.31 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0005 - Movement (7.19 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0006 - Staff - Toilet (4.65 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0007 - Staff Study (10.76 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0008 - Staff Study (26.19 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0009 - General Storeroom (23.66 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0010 - Distribution Board Cupboard (1.93 m2) Note: No inspection of live electrical installation.

Electrical Mounting Board Resinous Board 4Unit Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00A - R0011 - Staff - Toilet (4.8 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0012 - Darkroom Space (7.38 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0013 - Art Learning Space (78.02 m2)

Floor Coverings Res/Textile Vinyl Tiles 78m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Register Issue Date : Wednesday, 18 Sep 2019 Page 3 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00A - R0014 - General Storeroom (6.89 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0015 - Kiln Space (6.97 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0016 - Laboratory L.S. (91.84 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Clearance Certificate Note: If Vermiculite found, must be composite tested before disturbance works. Oversheeting with plasterboard/metal.

B00A - R0017 - Preparation (9.78 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0018 - Preparation (29.02 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0019 - Laboratory L.S. (91.38 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Clearance Certificate Note: If Vermiculite found, must be composite tested before disturbance works. Oversheeting with plasterboard/metal.

B00A - R0020 - Movement (13.94 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0021 - Distribution Board Cupboard (1.15 m2) Note: No inspection of live electrical installation.

Electrical Mounting Board Resinous Board 3Unit Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00A - R0022 - Computer Resource (10.3 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0023 - Telematics (25.93 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0024 - General Learning Space (52.74 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0025 - General Learning Space (51.58 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00A - R0026 - External Movement (655.12 m2)

No Asbestos

B00A - R0027 - Materials Store (30.39 m2)

Wall Linings Internal Flat AC Sheeting

No Asbestos Detected

B00A - R0028 - Dark Room (12.7 m2)

Wall Linings Internal Flat AC Sheeting

No Asbestos Detected

Register Issue Date : Wednesday, 18 Sep 2019 Page 4 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

Ceiling Structures/Linings Flat AC Sheeting

No Asbestos Detected

Register Issue Date : Wednesday, 18 Sep 2019 Page 5 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00B - Technological & Applied Studies - 1966 - Brick/Block

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids - Sub Structure

No Asbestos Found

Interior

B00B - R0001 - Materials Store (13.53 m2)

Ceiling Structures/Linings Vermiculite 14m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00B - R0005 - Materials Technology L.S. (82.19 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00B - R0006 - Resource/Project Store (11.52 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00B - R0007 - Materials Store (8.46 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00B - R0008 - Distribution Board Cupboard (2.58 m2) Note: No inspection of live electrical installation.

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00B - R0009 - General Storeroom (8.1 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00B - R0010 - Cleaning Store - Distributed (4.1 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00B - R0011 - Design L.S. (51.64 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00B - R0013 - Machine Storage (37.52 m2)

No Asbestos

B00B - R0014 - Plant (6.18 m2)

No Asbestos

B00B - R0016 - Materials Technology L.S. (39.02 m2)

No Asbestos

B00B - R0017 - Project Store - Type 1 (11.64 m2)

No Asbestos

B00B - R0018 - Materials Store (11.73 m2)

No Asbestos

B00B - R0019 - Metal Technology Bay (4.54 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00B - R0020 - Welding Area (3.56 m2)

Register Issue Date : Wednesday, 18 Sep 2019 Page 6 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00B - R0021 - Welding Area (3.56 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00B - R0022 - Welding Area (3.56 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00B - R0023 - Materials Technology L.S. (103.91 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00B - R0024 - External Movement (11.43 m2)

No Asbestos

B00B - R0025 - External Movement (67.04 m2)

No Asbestos

B00B - R0026 - External Movement (163.74 m2)

No Asbestos

Register Issue Date : Wednesday, 18 Sep 2019 Page 7 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00C - Technological & Applied Studies - 1966 - Brick/Block

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids - Sub Structure

No Asbestos Found

Interior

B00C - R0001 - Staff - Toilet (6.65 m2)

Ceiling Structures/Linings Vermiculite 7m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00C - R0002 - Staff - Toilet (5.78 m2)

Ceiling Structures/Linings Vermiculite 6m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00C - R0003 - Staff Study (26.51 m2)

Ceiling Structures/Linings Vermiculite 27m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00C - R0004 - General Storeroom (24.4 m2)

Ceiling Structures/Linings Vermiculite 25m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00C - R0005 - Cleaning Store - Distributed (2.48 m2)

No Asbestos

B00C - R0006 - Distribution Board Cupboard (1.9 m2) Note: No inspection of live electrical installation.

Electrical Mounting Board Resinous Board 5Unit Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0007 - Pantry (10.17 m2)

Ceiling Structures/Linings Vermiculite 11m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile Vinyl Tiles 11m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0008 - Staff Study (10.41 m2)

Ceiling Structures/Linings Vermiculite 11m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile Vinyl Tiles 11m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0011 - Materials Technology L.S. (64.66 m2)

Ceiling Structures/Linings Vermiculite 65m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile Vinyl Tiles 65m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0012 - Materials Store (6.3 m2)

Ceiling Structures/Linings Vermiculite 7m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile Vinyl Tiles 7m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0013 - Shower/Change (6.25 m2)

Register Issue Date : Wednesday, 18 Sep 2019 Page 8 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

Ceiling Structures/Linings Vermiculite 7m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

Floor Coverings Res/Textile Vinyl Tiles 7m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00C - R0014 - Movement (340.1 m2)

No Asbestos

B00C - R0015 -

No Asbestos

B00C - R0016 - Food Technology L.S. (89.47 m2)

Requires Inspection

B00C - R0017 - Food/Research Space (5.44 m2)

Requires Inspection

Register Issue Date : Wednesday, 18 Sep 2019 Page 9 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00D - Library - 1966 - Brick/Block

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids - Sub Structure

No Asbestos Found

Interior

B00D - R0001 - Workroom (24.76 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00D - R0002 - Seminar (10.86 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00D - R0003 - Seminar (10.84 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00D - R0005 - Distribution Board Cupboard (2.25 m2) Note: No inspection of live electrical installation.

Electrical Backing Board Resinous Board 4Unit Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00D - R0006 - Cleaning Supplies Store (7.98 m2)

No Asbestos

B00D - R0007 - Main Area (146.68 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00D - R0008 - Librarian (9.52 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00D - R0009 - General Storeroom (9.02 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00D - R0010 - Audio Visual Workroom (18.56 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00D - R0011 - Movement (347.18 m2)

No Asbestos

B00D - R0012 - Staff Study (14.65 m2)

No Asbestos

B00D - R0013 - Telematics (30.06 m2)

No Asbestos

Register Issue Date : Wednesday, 18 Sep 2019 Page 10 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00E - Administration - 1966 - Brick/Block

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids - Sub Structure

No Asbestos Found

Interior

B00E - R0003 - Principal Office (20.24 m2)

Ceiling Structures/Linings Vermiculite 21m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00E - R0004 - Interview/Office - Type 1 (12.82 m2)

Ceiling Structures/Linings Vermiculite 13m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00E - R0007 - Duplicating Workroom (15.72 m2)

Ceiling Structures/Linings Vermiculite 16m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00E - R0008 - General Storeroom (0.87 m2)

Ceiling Structures/Linings Vermiculite 1m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00E - R0009 - Distribution Board Cupboard (0.87 m2) Note: No inspection of live electrical installation.

Electrical Mounting Board Resinous Board 3Unit Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00E - R0010 - General Storeroom (5.6 m2)

Ceiling Structures/Linings Vermiculite 6m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00E - R0011 - General Storeroom (5.49 m2)

Ceiling Structures/Linings Vermiculite 6m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00E - R0012 - Deputy Principal Office (12.75 m2)

Ceiling Structures/Linings Vermiculite 13m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00E - R0013 - Seminar (16.72 m2)

Ceiling Structures/Linings Vermiculite 17m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00E - R0014 - Staff - Toilet (4.02 m2)

Ceiling Structures/Linings Vermiculite 5m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00E - R0015 - Staff - Toilet (4.03 m2)

Ceiling Structures/Linings Vermiculite 5m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00E - R0016 - Cleaning Store - Distributed (4.1 m2)

Ceiling Structures/Linings Vermiculite 5m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00E - R0017 - Clinic - Boys (20.02 m2)

Ceiling Structures/Linings Vermiculite 21m2 Throughout Friable Asbestos (5)

Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

Register Issue Date : Wednesday, 18 Sep 2019 Page 11 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00E - R0018 - Administration - Clerical (31.37 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00E - R0019 - Entry (42.71 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00E - R0020 - Movement (13.64 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

Floor Coverings Res/Textile Vinyl Tiles (Under Floor Covering/Carpet)

14m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Register Issue Date : Wednesday, 18 Sep 2019 Page 12 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00F - Pupil Facilities - 1966 - Brick/Block

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids - Sub Structure

No Asbestos Found

Interior

B00F - R0001 - Sport Equipment Store (18.16 m2)

Ceiling Structures/Linings Vermiculite 19m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0002 - General Storeroom (29.87 m2)

Ceiling Structures/Linings Vermiculite 30m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0003 - Cleaning Supplies Store (9.3 m2)

Ceiling Structures/Linings Vermiculite 10m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0004 - Movement (312.57 m2)

No Asbestos

B00F - R0005 - General Storeroom (6.66 m2)

Ceiling Structures/Linings Vermiculite 7m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0006 - Staff - Toilet (3.86 m2)

Ceiling Structures/Linings Vermiculite 4m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0007 - General Storeroom (5.34 m2)

Ceiling Structures/Linings Vermiculite 6m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0008 - Student Canteen (43.02 m2)

Ceiling Structures/Linings Vermiculite 43m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0009 - Garden Store Room (9.08 m2)

Ceiling Structures/Linings Vermiculite 10m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0010 - Plant (10.86 m2)

Ceiling Structures/Linings Vermiculite 11m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0011 - Main Switchroom (13.3 m2)

Electrical Mounting Board Resinous Board 4Unit Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00F - R0012 - Sport Equipment Store (12.25 m2)

Ceiling Structures/Linings Vermiculite 13m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0013 - Movement (9.47 m2)

Ceiling Structures/Linings Vermiculite 10m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0014 - Music Store (9.43 m2)

Register Issue Date : Wednesday, 18 Sep 2019 Page 13 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

Ceiling Structures/Linings Vermiculite 10m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0015 - Shower/Change (49.99 m2)

Ceiling Structures/Linings Vermiculite 50m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0016 - General Assistants (49.3 m2)

No Asbestos

B00F - R0017 - Shower/Change (67.15 m2)

Ceiling Structures/Linings Vermiculite 68m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

Partition Walls (Cubicles) Compressed AC Sheet 16m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0018 - General Storeroom (9.62 m2)

Ceiling Structures/Linings Vermiculite 10m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0019 - Toilets-Boys (59.96 m2)

Ceiling Structures/Linings Vermiculite 60m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

Partition Walls (Cubicles) Compressed AC Sheet 16m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0020 - Toilets-Girls (65.15 m2)

Ceiling Structures/Linings Vermiculite 66m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

Partition Walls (Cubicles) Compressed AC Sheet 20m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos)

Low Priority (2-3)

B00F - R0021 - Movement (488.46 m2)

No Asbestos

Register Issue Date : Wednesday, 18 Sep 2019 Page 14 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00G - General Learning/Science Learning - 1966 - Brick/Block

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids - Sub Structure

No Asbestos Found

Interior

B00G - R0001 - Apparatus Store (25.38 m2)

Floor Coverings Res/Textile Vinyl Tiles 26m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

B00G - R0002 - Chemical Store (3.2 m2)

Floor Coverings Res/Textile Vinyl Tiles 4m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00G - R0003 - Preparation (35.41 m2)

Floor Coverings Res/Textile Vinyl Tiles 36m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00G - R0004 - General Learning Space (93.25 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00G - R0005 - General Storeroom (24.94 m2)

No Asbestos

B00G - R0006 - Staff Study (26.04 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00G - R0007 - Staff Study (25.93 m2)

No Asbestos

B00G - R0008 - Computer Learning Space (53.18 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00G - R0009 - General Learning Space (52.52 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00G - R0010 - General Learning Space (52.89 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00G - R0011 - General Storeroom (23.36 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00G - R0012 - Distribution Board Cupboard (2.22 m2) Note: No inspection of live electrical installation.

No Asbestos

B00G - R0013 - General Learning Space (52.96 m2)

Register Issue Date : Wednesday, 18 Sep 2019 Page 15 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00G - R0014 - General Learning Space (52.96 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00G - R0015 - General Learning Space (51.72 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00G - R0017 - Machine Storage (25.24 m2)

No Asbestos

B00G - R0018 - Movement (601.17 m2)

No Asbestos

Register Issue Date : Wednesday, 18 Sep 2019 Page 16 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00H - General Learning - 1966 - Brick/Block

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids - Sub Structure

No Asbestos Found

Interior

B00H - R0001 - General Learning Space (51.51 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00H - R0002 - General Learning Space (52.74 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00H - R0003 - Computer Learning Space (52.52 m2)

No Asbestos

B00H - R0004 - Staff - Toilet (23.79 m2)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00H - R0005 - Distribution Board Cupboard (1.96 m2) Note: No inspection of live electrical installation.

No Asbestos

B00H - R0006 - Commonroom (78.6 m2)

Floor Coverings Res/Textile Vinyl Tiles 5m2 North, West Good Condition (1) Low (1)

Chrysotile (white asbestos)

Low Priority (2-3)

Ceiling Structures/Linings Vermiculite

Limited Samples Taken

Vermiculite Ceilings may contain asbestos. Asbestos testing MUST be conducted prior to any disturbance works

B00H - R0007 - External Movement (342.14 m2)

No Asbestos

Register Issue Date : Wednesday, 18 Sep 2019 Page 17 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00I - Agricultural Science - 1966 - Brick/Block

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids - Sub Structure

No Asbestos Found

Interior

B00I - R0002 - Staff - Toilet (11.8 m2)

Ceiling Structures/Linings Flat AC Sheeting 12m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos) , Crocidolite (blue asbestos)

Low Priority (2-3)

B00I - R0005 - Machine Storage (11.98 m2)

Ceiling Structures/Linings Flat AC Sheeting 12m2 Throughout Good Condition (1) Low (1)

Chrysotile (white asbestos) , Amosite (brown asbestos) , Crocidolite (blue asbestos)

Low Priority (2-3)

B00I - R0006 - Distribution Board Cupboard (0.4 m2) Note: No inspection of live electrical installation.

No Asbestos

B00I - R0007 - Machine Storage (44.16 m2)

No Asbestos

B00I - R0008 - Movement (39.49 m2)

No Asbestos

Register Issue Date : Wednesday, 18 Sep 2019 Page 18 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00J - Agricultural Science - 2008 - Steel

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids - Sub Structure

No Asbestos Found

Interior

B00J - R0001 - General Learning Space (50.87 m2)

No Asbestos

B00J - R0002 - External Movement (10.05 m2)

No Asbestos

Register Issue Date : Wednesday, 18 Sep 2019 Page 19 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00K - Technological & Applied Studies - 2008 - Brick/Block

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids - Sub Structure

No Asbestos Found

Interior

B00K - R0001 - Workshop (51.95 m2)

No Asbestos

Register Issue Date : Wednesday, 18 Sep 2019 Page 20 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00L - Science Learning - 2010 - Brick/Veneer

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids - Sub Structure

No Asbestos Found

Interior

B00L - R0001 - Seminar - Type 2 (21.11 m2)

No Asbestos

B00L - R0002 - Staff Kitchen (4.54 m2)

No Asbestos

B00L - R0003 - Staff Study (16.48 m2)

No Asbestos

B00L - R0004 - Movement (6.27 m2)

No Asbestos

B00L - R0005 - Preparation (30.39 m2)

No Asbestos

B00L - R0006 - Apparatus Store (13.84 m2)

No Asbestos

B00L - R0007 - Science Laboratory (60.05 m2)

No Asbestos

Clearance Certificate Note: Composite Tested and Oversheeted with Plasterboard.

B00L - R0008 - General Learning Space - Type 10 (59.9 m2)

No Asbestos

B00L - R0009 - External Movement (81.76 m2)

No Asbestos

B00L - R0010 - Chemical Store (11.91 m2)

No Asbestos

B00L - R0011 - Distribution Board Cupboard (0.54 m2) Note: No inspection of live electrical installation.

No Asbestos

Register Issue Date : Wednesday, 18 Sep 2019 Page 21 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00M - Agricultural Science - 2011 - Brick/Veneer

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids - Sub Structure

No Asbestos Found

Interior

B00M - R0001 - Agriculture Covered Area (55.34 m2)

No Asbestos

B00M - R0002 - General Learning Space - Type 10 (28 m2)

No Asbestos

B00M - R0003 - Outdoor Workshop (25.42 m2)

No Asbestos

Register Issue Date : Wednesday, 18 Sep 2019 Page 22 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

B00N - Pupil Facilities - 2013 - Metal Shed

Exterior

Underfloor Voids - Slab on Ground

No Asbestos Found

Ceiling Voids - Sub Structure

No Asbestos Found

Interior

B00N - R0001 - Sport Equipment Store (35.19 m2)

No Asbestos

Register Issue Date : Wednesday, 18 Sep 2019 Page 23 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

NS 120 - D15510 - Learning Unit - Single Primary H/Cap PAA - Placement Date: 26/09/1996

Exterior

No Asbestos Found.

Interior

R1 - Home Base-I.O.

No Asbestos Found.

R2 - Toilets-Disabled

No Asbestos Found.

R3 - Home Base Store-I.O.

No Asbestos Found.

R4 - Practical Activity Area

No Asbestos Found.

R5 - Entry

No Asbestos Found.

NS 020 - D16839 - Staff Study/Store - Placement Date: 26/01/2000

Exterior

No Asbestos found.

Interior

R1 - Staff Room

No Asbestos found.

R2 - Store

No Asbestos found.

R3 - Entry

No Asbestos found.

Register Issue Date : Wednesday, 18 Sep 2019 Page 24 of 258346 - Condobolin High School

ProductMaterial

Description ExtentLocation

ReferenceMaterial

ConditionRisk

StatusControlPriority

8346 Condobolin High School Sep 2019

Test Result

Listing of Electronic Attachments of AMP as of 17/09/2019

There are no asbestos related AMP file attachment(s) available for this school.

Register Issue Date : Wednesday, 18 Sep 2019 Page 25 of 258346 - Condobolin High School