HALL COUNTY PLANNING COMMISSION STAFF REPORT
Transcript of HALL COUNTY PLANNING COMMISSION STAFF REPORT
1.
HALL COUNTY PLANNING COMMISSION STAFF REPORT
Applicant ...................................................................... Provident Partners 129, LLC Request ........................................................................ Rezone from Agricultural Residential-IV (AR-
IV) to Light-Industrial (I-I) Proposed Use .............................................................. Distribution warehouse Size ............................................................................... 66.85± acres Zoning .......................................................................... AR-IV Location ....................................................................... On the south side of Athens Highway at its
intersection with Roy Parks Road; a.k.a. 3104 Athens Highway; Tax Parcel 15024 000227
Commission District ................................................... Three County Commission Date .......................................... August 2, 2021 Staff Recommendation ............................................... Denial
This request was tabled at the July 19, 2021 Planning Commission meeting.
Applicant Proposal
The applicant is requesting to rezone the subject property from Agricultural-Residential-IV (AR-IV) to
Planned Industrial Development (PID) for warehouse and distribution facilities. The proposed facility
will include three (3) buildings of various sizes totaling to 380,000 square feet in area. The warehouses
will facilitate the distribution of dry goods and possibly food-grade and general commodities, but not
refrigerated or frozen goods. The proposed design of the buildings include tilt-wall concrete and cross
docks with truck courts, as well as reveals and clerestory windows to enhance the building’s aesthetic.
As the property falls within the Gateway Corridors Overlay District (GCOD), the applicant requests
certain variances from this section of the code:
§17.420.050.C.1.c. Transitional Buffers –Transitional buffers are required along and inside the
property line at the perimeter of a planned development district that abuts single-family
residential zoning or uses, in accordance with the requirements of this subsection, but no
transitional buffers are required between dissimilar uses within the planned development
district.
o There is a 50-foot buffer depicted along the southern and eastern property on the
submitted site plan.
The applicant states that as the rear property line is heavily wooded and will
not be disturbed during construction, it is requested that no additional planting
be required in this area.
§17.420.050.D.5 Visual blending of slopes – Cuts and fills shall be terraced to blend into the
natural terrain. Cut or fill slopes more than ten feet in height shall be landscaped with evergreen
shrubbery planted at the rate of ten shrubs per 100 lineal feet.
2.
o The applicant states that as this is a light industrial development, it is requested that
this screening requirement be waived along Athens Highway (US Hwy. 129), Roy
Parks Road, and the rear property line.
§17.420.050.F.2.b Outdoor Lighting – Parking lot, sidewalk, and building illumination – Only
incandescent, florescent, metal halide, low-pressure sodium, or color corrected, high-pressure
sodium may be used. The same type of lighting must be used for the same or similar types of
lighting on any one site.
o The applicant states that as technology has improved since the adoption of the code,
it is requested that more energy-efficient LED lighting be installed and utilized.
§17.420.050.G.2.b Interparcel Access – A design speed of 15 mph and a two-way travel aisle
with a minimum paved width of 22 feet (back of curb to back of curb). Paving, base and curb
specifications shall meet Hall County's standards for public streets.
o The applicant states that the private access drive design will be designed to
accommodate anticipated truck traffic for the site and this requirement be waived
because this will not be a public road.
§17.420.050.G.2.d Interparcel Access – Driveway aprons, stub-outs and other design features
to indicate that abutting properties may be connected to provide cross access via a service
drive.
o The applicant states that while the private access road will provide vehicular access
between buildings, there will be no pedestrian connection between buildings. The
applicant asks that this requirement be waived.
§17.420.050.H.1.b Architectural Standards for Non-Residential Buildings - Building height Any
non-residential building located within 250 feet of a residential or agricultural use street shall
be limited to no more than three stories in height.
o The applicant states that while the buildings will be only 1 story in height, the exterior
walls will measure approximately 38 feet in height. The applicant asks that this
requirement be waived.
§17.420.050.H.2.c Architectural Standards for Non-Residential Buildings - Building materials
– Building materials used for all four sides of new or reconstructed buildings are restricted to
the following: Brick and/or Stone. Natural stone such as, but not limited to, granite, limestone,
and marble are allowed building materials. Terra cotta and/or cast stone, which simulate
natural stone, are also acceptable. Painted stone is prohibited. Split-face block/concrete
masonry unit (CMU) is restricted to 50 percent of the surface area of each side of a principal
building. Stucco is restricted to 50 percent of the surface area of each side of a building. Glass
and glass block. Exposed concrete block, painted concrete block, metal, tilt/up and pre-cast
concrete are prohibited materials for any exterior wall.
o The applicant states that while the buildings will be for light industrial use, i.e.
warehousing, and proposed construction will be 100% concrete tilt-wall construction
for the buildings. The applicant asks that this requirement be waived.
§17.420.050.H.3 Architectural Standards for Non-Residential Buildings - Roof materials –
Materials for pitched roofs shall be limited to architectural grade composition shingles, natural
slate, natural terra cotta, natural wood shake, or factory finished metal with standing seams.
o The applicant states that the industry standard roof for construction of this type is a
60mil white TPO membrance roof. The applicant asks that this requirement be waived.
3.
Proposed Development Standards:
Standard Proposed Official Code of Hall County
Min Lot Area: 15,000 sq. ft. 15,000 sq. ft. (§17.240.010)
Max Impervious Area: 80% 80% of lot area (§17.240.110)
Max Building 300,000 sq. ft. 80% of lot area (§17.240.110)
Max Building Height 35 ft. ≤ three stories (§17.420.050.H.1.B)
Min Lot Frontage: 100 ft. 150 feet (§16.50.040)
Front Building Setback (US129): 100 feet from c/l or
75 feet from property
line, whichever is
greater
100 feet from centerline of arterial
road (§17.240.040)
Exterior Buffer: No additional planting
at rear boundary
buffer
50 feet (§17.420.050.C.2.C)
Visual blending of slopes: Waive screening
requirement along
Athens Hwy, Roy
Parks Rd, and rear
boundary
Cut or fill slopes more than 10 feet to be landscaped with ten shrubs every 100 feet (§17.420.050.D.5)
Outdoor Lighting: LED lighting Only incandescent, florescent, metal
halide, low-pressure sodium, or color
corrected, high-pressure sodium may
be used. (§17.420.050.F.2.b)
Interparcel Access: Private access drive
designed to
accommodate
anticipated truck
traffic for the site.
A design speed of 15 mph and a two-
way travel aisle with a minimum
paved width of 22 feet (back of curb
to back of curb). Paving, base and
curb specifications shall meet Hall
County's standards for public streets.
(§17.420.050.G.2.b)
Interparcel Access: Private access road
will provide vehicular
access between
buildings; there will
be no pedestrian
connection between
buildings.
Access Driveway aprons, stub-outs
and other design features to indicate
that abutting properties may be
connected to provide cross access via
a service drive. (§17.420.050.G.2.d)
Architectural Standards: Industry standard
roof for construction
of this type is a 60mil
white TPO
membrance roof.
Materials for pitched roofs shall be
limited to architectural grade
composition shingles, natural slate,
natural terra cotta, natural wood
shake, or factory finished metal with
standing seams. (§17.420.050.H.3)
4.
History and Existing Land Uses
The subject property consists of 66.85± acres and is zoned Agricultural-Residential-IV (AR-IV). The
property is undeveloped and a mix of open and wooded areas. A stream is located near the western
boundary, and an overhead power line easement runs north and south through the middle. The
property has frontage on both Athens Highway (US Hwy. 129) and Roy Parks Road.
Adjacent properties to the west and across Athens Highway are also zoned AR-IV, and developed
with single-family residences or agricultural uses. The Bluffton Subdivision is located to the east, zoned
Residential-I (R-I) and is partially developed. Across Athens Highway are two cold warehouse facilities,
which are both zoned Light-Industrial (I-I). Across Roy Parks Road is a property zoned Planned
Commercial Development (PCD) for a gas station.
The subject property also falls within the Gateway Corridors Overlay District (GCOD), which is
supplemental to the underlying zoning district classification. The GCOD governs non-residential
property development standards.
Comprehensive Plan Land Use Designation
The subject property is located within a Mixed-Use/Revitalization corridor according to the Future Land
Use Designation. The primary future land uses within this type of corridor are for retail, office, higher
density residential (including multi-family), civic uses, and open/park spaces. Developments within this
corridor should be low-impact industrial or higher-density residential only where the same is found on
adjacent properties. The proposed use is inconsistent with the Comprehensive Plan as the adjacent
parcels are zoned Residential-I and Agricultural-Residential-IV. The parcel is separated from the non-
residential zoned properties by existing right-of-ways.
The corridor is primarily developed with large agricultural tract the subject parcel; however, the
immediate area across Athens Highway is also zoned I-I and there is a commercial development
across Roy Parks Road. Additionally, there has been recent non-residential and non-agricultural
development along this corridor to the north and south, though no rezoning requests have been
approved on adjacent parcels.
Development Support and Constraints
Public Facilities
The subject property is located approximately 2.5 miles from Hall County Fire Station #1, located at
2460 Athens Highway. There are multiple fire hydrants along Athens Highway and Roy Parks Road in
front of the subject property.
Hall County Environmental Health
In an email dated July 7, 2021 Emily McGahee stated that the development “Must meet all
Environmental Health commercial septic system permitting requirements. Further determination will
be made during the civil plan review process. A detailed business plan must be submitted to Hall
County Environmental Health for review. Additional items, including, but not limited to: recorded plat,
soil evaluation, and septic system installation may be required after review of business plan.”
Hall County Public Works and Utilities
In a memorandum from Public Works and Utilities on July 8, 2021, Director Srikanth Yamala stated
the following:
5.
Engineering
No comment
Traffic
1. Improve Roy Parks Road from Athens Highway (SR11/US129) to site access to Hall
County industrial/commercial standards.
2. Provide a left turn lane on Roy Parks Road for site access.
3. Development construction and business commercial traffic only be permitted to use Roy
Parks Road from site access to Athens Highway (SR11/US129) and the remainder of Roy
Parks Road will be restricted. Developer must provide and maintain the appropriate traffic
signage to ensure compliance.
4. Improvements to Roy Parks Road must be constructed concurrently with site development.
5. It will be the developer’s responsibility to coordinate Roy Parks Road improvements with
the Georgia Department of Transportation (GDOT) and acquire any necessary permits.
6. All costs associated with improvements will be the developer’s responsibility.
7. Site access along Athens Highway (SR11/US129) must be approved and permitted
through the Georgia Department of Transportation (GDOT).
Utilities
No sewer available
Hall County Tax Assessors
No comments provide.
Water Service
Per Hall County GIS, there is access to public water along Athens Highway.
Georgia Department of Transportation
In an email dated July 9, 2021, Parker Niebauer, a Traffic Operations Supervisor with GDOT, stated
that this project will require GDOT coordination.
Zoning Analysis
The proposed use for light manufacturing and warehouse/distribution facilities is inconsistent with
the Comprehensive Plan designation of a mixed use/revitalization corridor as the proposed
development is adjacent to single-family residential zoned parcels.
o The current corridor is primarily developed with large agricultural tracts in close proximity
to the subject parcel although there is nearby I-I zoned property.
It is anticipated that future development along Athens Highway may trend towards
more intensive non-residential and non-agricultural uses and would be classified
differently in an updated version of the Comprehensive Plan.
Per §17.180.090.B.2 of the Official Code of Hall County “The development controls for the district
shall be detailed (lot coverage, setbacks, building heights, lot sizes, etc.). If standards are not
specifically proposed, then the applicable standards in the light industrial (I-I) district, together with
the screening and buffer requirements, shall apply.”
6.
The GCOD provides guidelines for non-residential property development. The guidelines apply to
both permitted uses and development standards.
o Within the GCOD, the following uses are prohibited: adult entertainment, junk yards, and
billboard signs.
o Uses subject to the approval of the Hall County Board of Commissioners include: self-
storage warehouses, vehicle sales lots (new or used), automobile repair and maintenance,
commercial outdoor recreation, car wash, and outdoor storage.
Per §17.420.050.D.2.a, a ten-foot wide landscape strip is required along each street frontage,
continuous along the frontage except for perpendicular crossings for driveways and utilities.
o This is not depicted on the applicant’s submitted site plan; this condition is not met.
Per §17.420.050.D.4.d, all outdoor storage shall be screened from view from public streets and
adjacent property by a permanent opaque enclosure consisting of a minimum eight-foot high solid
fence or wall.
o No outdoor storage is proposed; this does meet the GCOD standard.
Per §17.420.050.C.2.C, the transitional buffers where an industrial zoning district abuts property
zoned for residential or agricultural use shall be no less than 50 feet and shall be placed along the
inside property line of the non-residential property.
o The applicant is requesting a buffer variance for the rear boundary where existing
vegetation shall not be supplemented with planting; this does not meet the GCOD
standard.
Per §17.420.050.D.3, if a loading or service area is located within 50 feet of a side or rear lot line
abutting residentially zoned property, then the loading or service area shall be surrounded by either
a six foot height masonry screening wall, or a six foot height solid wooden fence placed on the
inside of the required landscaped buffer.
o According to the site plan, this condition is met.
Per §17.420.050.E.4.A, each parking area over 50 spaces shall include landscaped islands within
the parking area equivalent to not less than five to ten percent with planning director discretion of
the total paved area of the parking lot.
o The narrative and/or site plan does not show landscape islands within the parking area,
this does not meet the GCOD standard.
Building materials for all four sides of a new building are restricted to the following: brick, stone,
and glass or glass block. Up to 50% of the surface area of each side may be stucco, and up to
50% of the surface area of each side of a principal building may be split-face block/concrete
masonry unit. Concrete block, painted concrete block, tilt-up and pre-cast concrete are not
allowed.
o The applicant is requesting a variance to allow exterior walls of the building to be tilt-
up or pre-stress concrete wall panels.
o This condition is not met.
Per §17.420.050.H.3, roof materials for pitched roofs shall be limited to architectural grade
composition shingles, natural slate, natural terra cotta, natural wood shake, or factory finished
metal with standing seams.
o The applicant is requesting a variance to allow an industry standard roof for construction
of this type to be a 60mil white TPO membrane roof.
o This condition is not met.
Per §17.420.050.F.1 outdoor lighting shall be provided on all public streets and parking lots.
o The applicant is proposing LED exterior lighting; this condition is not met.
7.
§17.250.020A of the Official Code of Hall County lists the following minimum parking standards
for the development:
o Office, office building or studio: 3.5 spaces for each 1,000 square feet of gross floor area
(§17.250.20A)
o Warehousing: 1 space for each 2 employees (§17.250.20A)
o Industrial uses: 1.6 spaces for each 1,000 square feet of gross floor area (§17.250.20A)
The applicant shows proposed parking for each building on the site plan; this
condition has been met.
The following recommendations have been provided by Hall County Traffic Engineering:
o Improve Roy Parks Road from Athens Highway (SR11/US129) to site access to Hall
County industrial/commercial standards.
o Provide a left turn lane on Roy Parks Road for site access.
o Development construction and business commercial traffic only be permitted to use Roy
Parks Road from site access to Athens Highway (SR11/US129) and the remainder of Roy
Parks Road will be restricted. Developer must provide and maintain the appropriate traffic
signage to ensure compliance.
o Improvements to Roy Parks Road must be constructed concurrently with site development.
o It will be the developer’s responsibility to coordinate Roy Parks Road improvements with
the Georgia Department of Transportation (GDOT) and acquire any necessary permits.
o All costs associated with improvements will be the developer’s responsibility.
o Site access along Athens Highway (SR11/US129) must be approved and permitted
through the Georgia Department of Transportation (GDOT).
Staff Recommendation
Staff recommends denial of the applicant’s request However, if the board sees fit to approve, staff
recommends that the following conditions shall apply:
1. The development shall conform substantially with the proposed narrative, modified as
necessary for compliance with current development standards at time of application.
2. All future development shall be subject to all standards set forth by the Gateway Corridor
Overlay District; no variances to these standards shall be approved.
3. The developer shall improve Roy Parks Road from Athens Highway (SR11/US129) to site
access to Hall County industrial/commercial standards.
4. The developer shall provide a left turn lane on Roy Parks Road for site access.
5. Development construction and business commercial traffic only be permitted to use Roy
Parks Road from site access to Athens Highway (SR11/US129) and the remainder of Roy
Parks Road will be restricted. Developer must provide and maintain the appropriate traffic
signage to ensure compliance.
6. Improvements to Roy Parks Road must be constructed concurrently with site development.
7. It will be the developer’s responsibility to coordinate Roy Parks Road improvements with the
Georgia Department of Transportation (GDOT) and acquire any necessary permits.
8. All costs associated with improvements will be the developer’s responsibility.
9. Site access along Athens Highway (SR11/US129) must be approved and permitted through
the Georgia Department of Transportation (GDOT).
10. All conditions of zoning shall become a part of any plat recorded for this property.
/EGG
BLUFFTONDR
IVE
ROYPARKS
ROAD
SOUTHCHASEDRIVE
BARRETT ROADSUGAR
HI LL
WAY
FAIRHILL DRIVE
J FARMER ROAD
PRIEST CIRCLE
REEC
ECIR
CLE
ATHENS
HIGHWAY
PENNINGTON
T RAIL
BAKERROAD
BOB BRYANT ROAD
DORSEYP EEK
ROAD
UVPCD
UVPCFD
UVR-I
UVPRD
UVR-I-L
UVH-B
UVS-S
UVPID
UVAR-IVUVI-I
0 600 1,200300Feet
Subject Area
±Zoning BoundaryCity LimitsSubject AreaStructure
Applicant: PROVIDENT PARTNERS 129, LLC Tax Parcel #: 15024 000227 Location: 3104 ATHENS HIGHWAY, GAINESVILLE, GA 30507 Commission District 3 PC Mtg. Date: 07/19/2021
ROY
PARK
SRO
AD
SOUTH MEADOW COURT
BLUF
FTON
DRIVE
FAIR
HILLDRIVE
ATHENSHIGHWAY
J FARMER ROAD
UVR-I
UVAR-IV
UVPCD
UVH-BUVI-I
0 200 400100Feet
±Zoning BoundaryCity LimitsSubject AreaStructure
Subject Area
Applicant: PROVIDENT PARTNERS 129, LLC Tax Parcel #: 15024 000227 Location: 3104 ATHENS HIGHWAY, GAINESVILLE, GA 30507 Commission District 3 PC Mtg. Date: 07/19/2021
ROY
PARK
S RO
AD
SOUTH MEADOW COURT
BLUF
FTON
DRIVE
FAIR
HILLDRIVE
ATHENSHIGHWAY
J FARMER ROAD
UVR-I
UVI-I
UVR-I
UVAR-IV
UVPCD
UVH-B
UVAR-IV
UVI-I
0 200 400100Feet
±Zoning BoundaryCity LimitsSubject Area
Applicant: PROVIDENT PARTNERS 129, LLC Tax Parcel #: 15024 000227 Location: 3104 ATHENS HIGHWAY, GAINESVILLE, GA 30507 Commission District 3 PC Mtg. Date: 07/19/2021
1
Laura Ogletree (Planning)
From: Emily McGahee (Environmental Health)Sent: Wednesday, July 7, 2021 3:54 PMTo: Laura Ogletree (Planning); Sarah McQuade (Planning)Cc: Chad Harper (Environmental Health); Kelly Hairston (Environmental Health)Subject: HCPC Tentative Agenda for 7.19.21
Please find Environmental Health comments below: Items 1 and 2, 0/4258 Cagle Road, Cagle Road LLC: No comment. Public Sewer. Item 3, 1400/1515 River Place: No comment. Public sewer. Item 4, 4157 Arthur Miller Road, Gay: Must meet all Environmental Health residential septic system permitting requirements. Level 3 Soil Evaluation and to-scale site plan required at time of permit application. Item 5, 1507 Browns Bridge Ave, Calvo: Existing septic system approved for a total of 2 bedrooms only. Floor plan will be required prior to any approval for new construction. Item 6, 3623 Dorsey Circle, Conde Properties: In 2001, Environmental Health issued septic permit 01-00681 to allow construction of a new home with the condition that the existing mobile home be removed from the property. This property does not meet the area requirements to support 2 residential structures as required by the Hall County Board of Health Lot Size Resolution; therefore, Environmental Health cannot approve any building permits for upgrades/renovations to the mobile home. Item 7, 3104 Athens Hwy, Provident Partners: Must meet all Environmental Health commercial septic system permitting requirements. Further determination will be made during the civil plan review process. A detailed business plan must be submitted to Hall County Environmental Health for review. Additional items, including, but not limited to: recorded plat, soil evaluation, and septic system installation may be required after review of business plan. Item 8, 4240 Winder Hwy, Aoun: No comment. Public Sewer. Item 9, 3835/3875 Cornelia Hwy, GA Lula Cornelia Hwy, LLC: No comment. Public Sewer. Item 10, 5697 Green Road, Jackson: All proposed lots must meet Hall County Board of Health Lot Size Resolution requirements. Item 11, 3818 Falcon Pkwy, Lam: Must meet all Environmental Health commercial septic system permitting requirements. Further determination will be made during the civil plan review process. A detailed business plan must be submitted to Hall County Environmental Health for review. An existing system evaluation and/or septic system installation/modification may be required. Items 12 and 13, 4152 Browns Bridge Road, Lanier Luxe: Must meet all Environmental Health commercial septic system permitting requirements. Further determination will be made during the civil plan review process. A detailed business plan must be submitted to Hall County Environmental Health for review. An existing system evaluation and/or septic system installation/modification may be required. Item 14, 5092/5118 Hog Mountain, McGee: Must meet all Environmental Health commercial septic system permitting requirements. Further determination will be made during the civil plan review process. A detailed business plan must be
2
submitted to Hall County Environmental Health for review. Additional items, including, but not limited to: recorded plat, soil evaluation, and septic system installation may be required after review of business plan. Item 15, 5301 L. J. Martin Road, Skelton: A variation of this subdivision plat (2 lots) was approved by our office on June 9, 2021. Any further subdivision of the property must meet all Hall County Board of Health Lot Size Resolution Requirements. Emily McGahee Hall County Environmental Health Hall County Government Center – 3rd Floor 2875 Browns Bridge Road Mailing: PO Box 5901 Gainesville, GA 30504 (770) 531-3973 (770) 531-6767 (fax) http://dph.georgia.gov/environmental‐health (State Website) http://www.phdistrict2.org/HallCounty.htm (District Website) http://www.hallcounty.org/devserv/environmental.asp (County Website & Forms)
Hall County Government PUBLIC WORKS AND UTILITIES
POST OFFICE DRAWER 1435 GAINESVILLE, GA 30503
t: 770.531.6800 | f: 770.531.3945
SRIKANTH YAMALA Director
BILL NASH, P.E.
Assistant Director
M E M O R A N D U M
To: Sarah McQuade, Director of Planning and Development
From: Srikanth Yamala, Director of Public Works and Utilities
Date: July 8, 2021
Subject: July 19, 2021 Hall County Planning Commission Agenda
Please be advised that our office has reviewed the Hall County Planning
Commission agenda for the June 23, 2021 meeting. Upon review, we
provide the following comments:
1. Previously tabled application of Cagle Rd, LLC for a Use Subject to County Commission approval on 31.50± acres located on the south side of Cagle Road across from its intersection with Oak Lake Drive; a.k.a. 0, 0, and 4258 Cagle Road, Zoned AR-III; Tax Parcels 09098 000007, 000008, and 000002. Proposed Use: sawmill, lumberyard, wood boiler, and biofuel plant. ** Commission District 3.
a) Engineering: No Comment
b) Traffic: Previous Comments Apply
c) Utilities: No Comment 2. Previously tabled application of Cagle Rd, LLC to rezone from Agricultural Residential-III (AR-III) to Heavy Industrial (I-II) on 31.50± acres located on the south side of Cagle Road across from its intersection with Oak Lake Drive; a.k.a. 0, 0, and 4258 Cagle Road, Zoned AR-III; Tax Parcels 09098 000007, 000008, and 000002. Proposed Use: sawmill, lumberyard, wood boiler, and biofuel plant. ** Commission District 3.
a) Engineering: No Comment
b) Traffic: Previous Comments Apply
c) Utilities: No Comment 3. Previously tabled application of Northeast Georgia Health System, Inc. (NGHS) to rezone from Planned Commercial Development (PCD) and Planned Office Development (POD) to Planned Office Development (POD) and to amend conditions of a Planned Office Development (POD) on a 119.16± acre tract located on the north side of Friendship Road approximately 1680 feet from its intersection with Old Winder Highway; a.k.a. 1400 & 1515 River Place; Zoned POD & PCD; Tax Parcels 15039 000465 & 000592. Proposed Use: amend parking requirements. ** Commission District 1.
a) Engineering: No Comment
b) Traffic: No Traffic Comments
c) Utilities: No Comment
4. Application of Ronald Gay for a rear yard setback variance from 25 feet to 15 feet on a 0.68± acre tract located on the east side of Arthur Miller Road 900± feet from its intersection with Old Cornelia Highway; a.k.a. 4157 Arthur Miller Road; Zoned AR-IV; Tax Parcel 15018 000181. Proposed Use: construct a single-family residence. * Commission District 3.
a) Engineering: No Comment
b) Traffic: No Traffic Comments
c) Utilities: No Comment
5. Application of Emiliano Arroyo Calvo a Use Subject to Planning Commission approval on a 0.36± acre tract located on the west side of Browns Bridge Avenue approximately 320 feet from its intersection with Carter Street; a.k.a. 1507 Browns Bridge Road; Zoned O-I; Tax Parcel 00123 007020A. Proposed Use: expansion of a non-conforming use – enclose existing carport for residential purposes. * Commission District 4.
a) Engineering: No Comment
b) Traffic: No Traffic Comments
c) Utilities: No Comment
6. Application of Sergio Felix/Conde Properties, LLC a Use Subject to Planning Commission approval on a 0. 47± acre tract located on the east side of Dorsey Circle approximately 445 feet from its intersection with Dorsey Drive; a.k.a. 3623 Dorsey Circle; Zoned AR-III; Tax Parcel 08034 002014. Proposed Use: expansion of a non-conforming use –two residences on one parcel. * Commission District 2.
a) Engineering:
b) Traffic: No traffic comments
c) Utilities:
7. Application of Provident Partners 129, LLC to rezone from Agricultural Residential-IV (AR-IV) to Light Industrial (I-I) on a 66.85± acre tract located on the south side of Athens Highway at its intersection with Roy Parks Road; a.k.a. 3104 Athens Highway; Zoned AR-IV; Tax Parcel 15024 000227. Proposed Use: distribution warehouse. ** Commission District 3.
a) Engineering: No Comment
b) Traffic: We recommend the following: 1. Improve Roy Parks Road from Athens Highway (SR11/US129)
to site access to Hall County industrial/commercial standards. 2. Provide a left turn lane on Roy Parks Road for site access. 3. Development construction and business commercial traffic
only be permitted to use Roy Parks Road from site access to Athens Highway (SR11/US129) and the remainder of Roy Parks Road will be restricted. Developer must provide and maintain the appropriate traffic signage to ensure compliance.
4. Improvements to Roy parks Road must be constructed concurrently with site development.
5. It will be the developer’s responsibility to coordinate Roy Parks
Road improvements with the Georgia Department of Transportation (GDOT) and acquire any necessary permits.
6. All costs associated with improvements will be the developer’s responsibility.
7. Site access along Athens Highway (SR11/US129) must be approved and permitted through the Georgia Department of Transportation (GDOT).
c) Utilities: No Sewer Available
8. Application of Maroum Aoun to rezone from Agricultural Residential-III (AR-III) to Planned Office Development (POD) on a 7.51± acre tract located on the west side of Winder Highway approximately 880 feet from its intersection with Martin Road; a.k.a. 4240 Winder Highway, Zoned AR-III; Tax Parcel 15044B000009. Proposed Use: daycare center. ** Commission District 1.
a) Engineering: Green Drive ROW Extends Through Property
b) Traffic: No traffic comments
c) Utilities: Oakwood Sewer
9. Application of GA Lula Cornelia Hwy, LLC to rezone from Agricultural Residential-III (AR-III) to Planned Industrial Development (PID) on 79.70± acres located on the north side of Cornelia Highway approximately 4,700 feet from its intersection with Cagle Road, a.k.a. 3835 and 3875 Cornelia Highway, Zoned AR-III and I-I; Tax Parcels 15007 000095A and 000276. Proposed Use: office and warehouse. ** Commission District 3.
a) Engineering: Stormwater Must Meet Hall County Regulations
b) Traffic: Access must be approved and permitted through the Georgia Department of Transportation (GDOT).
c) Utilities: Sewer Design Shall Be Part Of Development Plan
10. Application of Jason Jackson to rezone from Agricultural Residential-III (AR-III) to Planned Residential Development (PRD) on a 3.804± acre tract located on the east side of Green Road approximately 265 feet from its intersection with Holiday Road; a.k.a. 5697 Green Road; Zoned AR-III; Tax Parcel 07329 004016. Proposed Use: 5-lot subdivision. ** Commission District 1.
a) Engineering: No Comment
b) Traffic: No Traffic Comments
c) Utilities: No Comment
11. Application of Hung Lam to rezone from Agricultural Residential-III (AR-II) to Highway Business (H-B) on a 3.86± acre tract located on the west side of Falcon Parkway approximately 155 feet from its intersection with Chris Avenue; a.k.a. 3818 Falcon Parkway; Zoned AR-III; Tax Parcel 08050 001005. Proposed Use: outdoor storage – boat and RV storage. ** Commission District 2.
a) Engineering: Stormwater Shall Meet Hall County Standards
b) Traffic: Access must be approved and permitted through the Georgia Department of Transportation (GDOT).
c) Utilities: No Comment
12. Application of Lanier Luxe Self Storage to rezone from Residential-I and
Agricultural Residential-III (AR-III) to Highway Business (H-B) on a 9.862± acre tract located on the north side of Browns Bridge Road at its intersection with Cherokee Trail; a.k.a. 4152 Browns Bridge Road; Zoned R-I & AR-III; Tax Parcel 08050 003002. Proposed Use: self-storage warehouse. ** Commission District 2.
a) Engineering: No Comment
b) Traffic: We recommend site access be on Browns Bridge Road (SR 369). If access on Cherokee Trail is considered, we recommend the following:
1. Improve Cherokee Trail from Browns Bridge Road (SR 369) to site access to Hall County commercial standards including, but not limited to, roadway width, pavement section, turning radii at Browns Bridge Road (SR 369) and markings.
2. The gated access must be appropriately designed to allow vehicles to stage without protruding into Cherokee Trail.
3. It will be the developer’s responsibility to acquire any necessary permits from the Georgia Department of Transportation (GDOT).
4. Required improvements will be constructed concurrently with site development.
5. All costs associated with improvements will be the developer’s responsibility.
c) Utilities: No Comment
13. Application of Lanier Luxe Self Storage for a Use Subject to Planning Commission approval on a 9.862± acre tract located on the north side of Browns Bridge Road at its intersection with Cherokee Trail; a.k.a. 4152 Browns Bridge Road; Zoned R-I & AR-III; Tax Parcel 08050 003002. Proposed Use: caretaker or employee residence. * Commission District 2.
a) Engineering: No Comment
b) Traffic: No traffic comments regarding caretaker residence request. Development comments above.
c) Utilities: No Comment
14. Application of C. Sam McGee to rezone from Agricultural Residential-III to Planned Commercial Development (PCD) on a combined 6.41± acres located on the west side of Hog Mountain Road approximately 1,760 feet from its intersection with Holland Dam Road; a.k.a. 5092 and 5118 Hog Mountain Road; Zoned AR-III; Tax Parcels 08116 000002 and 000007. Proposed Use: self-storage warehouse. ** Commission District 1.
a) Engineering: Submit Combination Plat
b) Traffic: No traffic comments
c) Utilities: No Comment
15. Application of Mark Skelton to rezone from Agricultural Residential-III to Residential-I (R-I) on a 6.41± acre tract located on the north side of L J Martin Road approximately 1,235 feet from its intersection with Strickland Road; a.k.a. 5301 Strickland Road; Zoned AR-III; Tax Parcel 15037 000031. Proposed Use: 3-lot subdivision. ** Commission District 1.
a) Engineering: No Comment
b) Traffic: No Traffic Comments
c) Utilities: No Comment