H-14-111017 SH 001-00-10-20190929165333515 1...2019/09/29  · FOR ASME B31.3 ANALYSIS SEE...

1
7 GENERAL NOTES: (UNLESS 1. DIMENSIONS ARE IN INCHES. TOLERANCES: (UNLESS OTHERWISE SPECIFiED) F DECIMALS ANGULAR FRAC11ONS .XX±O.O15 .)C<X±O.010 ±0.5' ±1/16" 2. ESTIMATED DRY ASSEMBLY WEIGHT IS 6000 POUNDS. 3. REMOVE ALL BURRS AND SHARP EDGES. i Ij 4. THREADS PER ASME B1.1-1989. 250' 5. MACHINED SURFACES SHALL BE V OR BETTER IN ACCORDANCE WITH ASME B48.1. LATEST REVISION. FABRICATE, WELD. INSPECT. AND TEST PRESSURE RETAINING COMPONENTS PER ANSI/ASME B31.3, NORMAL FLUID SERVICE. ALL WELDS SHALL BE EXAMINED WY AN AWE QC -1 CER11F1ED WELD INSPECTOR. HYDROSTATIC LEAK PRESSURE TEST DILUTION WATER PIPING TO 375 PSIG (-O/+10 PSIG), AND ALL OTHER PIPING TO 600 PSIG (-0/+1O PSIG). IN-PROCESS EXAMINATION OF PROCESS HOSE UPPER CHEM JOINT IS ALLOWED. ACCEPTANCE CRIIERLA IS NO LEAKS. 7. WELD AND INSPECT STRUCTURAL WELDS PER AWS D1.1 FOR STATICALLY LOADED STRUCTURES. EXCEPT WHERE SPECIFICALLY NOTED TO WELD TO ASME B31.3. VT WELDS ON FiNAL PASS. WELDING PROCEDURES AND QUALIF1CA11ONS PER ASME SECTION IX ARE ACCEPTABLE. ALL WELDS SHALL BE EXAMINED WY AN AWS QC -1 CER11F1ED WELD INSPECTOR. 8. THE ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH 2014 NFPA-70 NEC. PAINTING & LABEL REQUIREMENTS: A) PREPARE AND PANT TOP FLANGE. WINCH MOUNT. AND MISCELLANEOUS BRACKETRY WITH A SINGLE COAT OF INDUSTRLAL GRADE STEEL PRIMER. APPLY TWO FiNISH COATS OF PPG WATERBORNE ACRYUC ENAMEL OR APPROVED ALTERNATIVE. FiNISH COLOR SHALL BE GRAY. APPLY PANT PER MANUFACTURER'S SPECIFiCATIONS. POWDER COAT IS AN ACCEPTABLE COATING SYSTEM. B) LABEL PUMP ASSEMBLY WITH ITEM NAME. DRAWING NUMBER, SERIAL NUMBER, AND ACTUAL WEIGHT USING 1/2" TO 3/4" HIGH CHARACTERS. COLOR SHALL BE BLACK ON YELLOW BACKGROUND. IDENI1FICA110N INFORMATION SHOULD BE READABLE FROM ABOVE IF POSSIBLE. DECALS OR PAINT ARE ACCEPTABLE. C) PUMP ASSEMBLY (ITEM 1) SHALL BE WEIGHED WY M&TE. THIS WEIGHT (IN LBS) SHALL BE INDICATED PER NOTE 9B. 10. FOR INSPECTION, TESTING AND SHIPPING OF THE PUMP ASSEMBLY. SEE SPECIFiCATION RPP-SPEC-62O12. 11. DESIGN PRESSURE OF THE PUMP ASSEMBLY IS 400 PSIG 0 1 80'F. FLEXIBLE HOSE ASSEMBLY SHALL BE PROCURED IN ACCORDANCE WITH HOSE SPEC RPP-14859, CURRENT REVISION. 13. SEE RPP-CALC-83O15 FOR SUPERHATANT PUMP ASSEMBLY OPERATIONAL STRUCTURAL ANALYSIS. AND RPP-CALC-63344 FOR UFI1NG ANALYSIS. 14. FOR ASME B31.3 ANALYSIS SEE RPP-CALC-62148. H-2-9O185-020 NOZZLE: ASME SECTION IX PIOH MATERLAL 18. DISCHARGE PIPING (PRESSURE BOUNDARY) WHEN INSTALLED IS A CLASS I. DMSION I GROUP B. HYDROGEN HAZARDOUS LOCATIONS PER HNF-SD-WM-HC-017. FOR ATEX EQUIVALENT SAFETY TECHNICAL EVALUATION FOR PIPING, PUREE CONNECTORS, AND THREADED CONNECTIONS INCLUDING CHEM JOINTS, SEE RPP-TE-58251. THE LOWER HYDRAULIC HOSES (ITEMS 57. 59. AND 60) SHALL HAVE FEMALE JIC SWIVEL ON BOTH ENDS. THE UPPER HYDRAUUC HOSES (ITEMS 53, 54, AND 55) SHALL HAVE 90 DEG ELBOW FEMALE JIC SWIVEL ON ONE END AND MALE NET ON 11-IE OTHER END. END F1NGS SHALL MATCH HOSE SIZE. HOSES SHALL BE ASSEMBLED WITH QUICK DISCONNECTS (ITEMS 136, 137, OR 138 ACCORDING TO HOSE SIZE). ALL FIITINGS SHALL BE STEEL USE MANUFAC11JRER'S RECOMMENDED FITI1NGS. LENGTH OF HOSE SHALL BE MEASURED FROM THE FACE OF THE NUT ON THE END F1TI1NG. PERFORM HYDROSTATIC PRESSURE TEST ON ASSEMBLED HOSES USING QUAKER QUINTOLUBRIC 888-46 HYDRAUUC FLUID. TEST PRESSURE SHALL BE 6000 PSI (-0, +200 PSI), HOLD FOR A MINIMUM OF 30 SECONDS AND A MAXIMUM OF 80 SECONDS. IN-PROCESS EXAMINATiON OF UPPER HYDRAUUC HOSE QUICK DISCONNECT FITTINGS IS ALLOWED. ACCEPTANCE CRITERIA IS NO LEAKS. 18. PUMP ASSEMBLY SHALL BE FULLY RETRACTED. I.E. IN THE UP POSITION. WHEN LIFTED FROM HORIZONTAL TO VERTICAL PRIOR TO AND FOLLOWING MOUNTING OF THE PUMP ONTO THE PUMP ASSEMBLY. PERFORM PERIODIC PUMP ROTATION PER MANUFACTURER'S INSTRUCTIONS. RECORD AND SUBMIT MAJNTENANCE RECORDS. TORQUE 3/4" PUMP MOUNTING BOLTS TO 63 FT-LBS. USE 3/4" CS HARDENED FLAT WASHERS AS REQUIRED UNDER THE BOLT HEADS TO PREVENT BOLTS FROM BOTTOMING 01ff AGAJNST THE PLUGS INSTALLED IN THE TAPPED HOLES. MAINTAIN A MINIMUM OF 1" THREAD ENGAGEMENT ON ALL PUMP MOUNTING BOLTS. CLEAN AND DRY THREADS. APPLY RED LOCT1TE AT FINAL INSTALLATION. [>. THE COMPONENT IS SAFElY SIGNIFICANT AND SHALL BE PURCHASED FROM AN EVALUATED SUPPLIER OR CGI DEDICATED PRIOR TO INSTALLATION. THE ITEM SHALL BE PERMANENTLY MARKED (SIZE PERMITTING) WITH PURCHASE ORDER NUMBER, DRAWING NUMBER & PARTS/MATERIAL LIST ITEM NUMBER. FABRICATOR SHALL SUBMIT "CMTR'S" FOR ALL SAFETY SIGNIFICANT MATERIALS. INCLUDING WELD FILLER MATERIAL. WHERE APPLICABLE. CNIR'S AND MARKING NOT REQUIRED FOR MALE NOZZLE (ITEM 31). 21. FOR MATERIAL COMPATIBILITY EVALUATION SEE RPP-RPT-6O770. FABRICATE AND INSTALL HYDRAUUC JUMPER HOSE ASSEMBLY WHILE PUMP ASSEMBLY IS IN STORAGE TO ALLOW FOR PERIODIC PUMP ROTATION. f >. PROViDE A MINIMUM OF 50 FEET OF 4/C 14 AWG TYPE TC-ER CABLE FOR FIELD CONNECTION OF UMIT SWITCH. WHEN NOT CONNECTED TO HYDRAULIC EXTENSION HOSE, CAP 3/4" UNE WITH DUST CAP (ITEM 139). j >. THIS IS AN ASME B31 .3 ATTACHMENT WELD. j >. MODIFIED WY REMOVING SPRING AND CHECK VALVE. HEAT TRACE AND INSULATE THE HYDRAULIC HOSES AS A BUNDLE ABOVE THE PUMP FLANGE. SPIRAL WRAP THE HOSES USING A 1.3:1 RATIO. INSTALL END SEAL KIT AT FLANGE END OF HOSES AND LEAVE 5 FEET MINIMUM OF D<TRA HEAT TRACE AT WHIP END FOR FIELD SPLICING/CONNECTION. INSULATE USING 2" CERAMIC FIBER. INSULATION DENSITY OF 8PCF, GRAY SIUCONE JACKETED INSULATiON. INSTALL PER MANUFACTURER'S INSTRUCTIONS. HEAT TRACE LABELS (RAYCHEM #ETL) SHALL BE INSTALLED ON OUTER INSULATION PER NEC 427.13. ROUTE SPEED SENSOR CABLE WITH HYDRAULIC HOSES. TO THE EXTENT POSSIBLE INSTALL SHRINK TUBE OR SHRINK WRAP (ITEM 142) WHERE POSSIBLE AND APPROXIMATELY TO END OF HOSES. 8 7 6 5 4 3 --- N / [>. WIRE ROPE TO BE FROM A REPUTABLE MANUFACTURER (WIRECO. LOOS & CO., ETC.). MINIMUM BREAKING STRENGTH / SHALL BE 15,900 LBS. MINIMUM WORKING LOAD LIMIT (WLL) SHALL BE BASED ON A 5:1 SAFETY FACTOR OF WIRE / ROPE BREAKING STRENGTH. THE MINIMUM WLL SHALL NOT BE LESS THAN 3,180 LBS. THE OPEN SWAGE SOCKET SHALL BE STAJNLESS STEEL (UPSON WALTON PART NUMBER 40043850 OR APPROVED EQUAL). LOAD TEST COMPLETED ASSEMBLIES IN ACCORDANCE WITH ASME B3O.9. SUBMIT ALL TEST REPORTS. ACTEK SWIVEL HOIST RING NOTES: I A. ALL SWIVEL HOIST RINGS SHALL BE AS MANUFACTURED WY ACTEK MANUFACTURING AND ENGINEERING INC. INSTALL/RE-INSTALL THESE HOIST RINGS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS EXCEPT AS AMENDED AND DOCUMENTED IN VENDOR INFORMATION FILE #VI-5O159. THE MANUFACTURER'S AMENDED INFORMATION AND/OR OTHER RELEVANT INFORMATION IS DESCRIBED IN THE FOLLOWING NOTES. \ \ B. ALL STEEL COMPONENTS ENGAGING THE HOIST RINGS SHALL HAVE MINIMUM TENSILE STRENGTHS OF 58,000 PSI. C. ALL ACTEK HOIST RING SCREW THREADS ARE CLASS BA, THEREFORE. ALL TAPPED THREADS SHALL BE MATCHING CLASS 2B. D. PRIOR TO ITS USE, EACH HOIST RING SHALL BE TIGHTENED TO TORQUE VALUE AS SHOWN BELOW. PAINT TO BE APPLIED FOLLOWING FINAL TORQUE. I ACTEK I RATED LOAD TORQUE FI-LB I HOIST RING SCREW SIZE (LBS) I (±10%, 1RART NUMBER I 46206-C I 3/4-10 UNC I 7,000 I 100 I E. IF "ANTI-SEIZE" LUBRICANT IS PRESENT IN THE THREADS OF THE HOIST RING SCREW OR IN THE TAPPED THREADS, IT MUST BE REMOVED WITH ACETONE OR ANOTHER VENDOR APPROVED SOLVENT. F. INSPECTION OF HOIST RINGS SHALL MEET MANUFACTURER'S AND HANFORD SITE HOISTING AND RIGGING MANUAL (DOE-RL-92-36) REQUIREMENTS. SUPERNATANT PUMP ASSEMBLY SCALE: 1/16 -AR-i H-15-7 A-FARM WRS AP PIT MODELS H-14-111014 DRAWING LIST & TITLE SHEET RELEASED PER EDT -882295 4750 5 4 3 \ / 2 2 U.S. DEPARTMENT OF ENERGY Offloo of RIVer Plotootloo A-FARM RETRIEVAL ADJUSTABLE SN PUMP GENERAL NOTES FH-14-111O17 1 82 NONE 18220 1 O'O F E C H-14-111017 SH 001 Rev.00 9/29/2019 - 4:54 PM 1 of 1 Sep 29, 2019 DATE:

Transcript of H-14-111017 SH 001-00-10-20190929165333515 1...2019/09/29  · FOR ASME B31.3 ANALYSIS SEE...

Page 1: H-14-111017 SH 001-00-10-20190929165333515 1...2019/09/29  · FOR ASME B31.3 ANALYSIS SEE RPP-CALC-62148. H-2-9O185-020 NOZZLE: ASME SECTION IX PIOH MATERLAL 18. DISCHARGE PIPING

7

GENERAL NOTES: (UNLESS1. DIMENSIONS ARE IN INCHES.

TOLERANCES: (UNLESS OTHERWISE SPECIFiED)

F DECIMALS ANGULAR FRAC11ONS.XX±O.O15 .)C<X±O.010 ±0.5' ±1/16"

2. ESTIMATED DRY ASSEMBLY WEIGHT IS 6000 POUNDS.

3. REMOVE ALL BURRS AND SHARP EDGES.

i

Ij

4. THREADS PER ASME B1.1-1989.

250'5. MACHINED SURFACES SHALL BE V OR BETTER IN ACCORDANCE WITH ASME B48.1. LATEST REVISION.

FABRICATE, WELD. INSPECT. AND TEST PRESSURE RETAINING COMPONENTS PER ANSI/ASME B31.3,NORMAL FLUID SERVICE. ALL WELDS SHALL BE EXAMINED WY AN AWE QC-1 CER11F1ED WELD INSPECTOR.HYDROSTATIC LEAK PRESSURE TEST DILUTION WATER PIPING TO 375 PSIG (-O/+10 PSIG), AND ALLOTHER PIPING TO 600 PSIG (-0/+1O PSIG). IN-PROCESS EXAMINATION OF PROCESS HOSE UPPERCHEM JOINT IS ALLOWED. ACCEPTANCE CRIIERLA IS NO LEAKS.

7. WELD AND INSPECT STRUCTURAL WELDS PER AWS D1.1 FOR STATICALLY LOADED STRUCTURES. EXCEPTWHERE SPECIFICALLY NOTED TO WELD TO ASME B31.3. VT WELDS ON FiNAL PASS. WELDING PROCEDURESAND QUALIF1CA11ONS PER ASME SECTION IX ARE ACCEPTABLE. ALL WELDS SHALL BE EXAMINED WY AN AWSQC-1 CER11F1ED WELD INSPECTOR.

8. THE ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH 2014 NFPA-70 NEC.

PAINTING & LABEL REQUIREMENTS:

A) PREPARE AND PANT TOP FLANGE. WINCH MOUNT. AND MISCELLANEOUS BRACKETRY WITH A SINGLECOAT OF INDUSTRLAL GRADE STEEL PRIMER. APPLY TWO FiNISH COATS OF PPG WATERBORNE ACRYUCENAMEL OR APPROVED ALTERNATIVE. FiNISH COLOR SHALL BE GRAY. APPLY PANT PERMANUFACTURER'S SPECIFiCATIONS. POWDER COAT IS AN ACCEPTABLE COATING SYSTEM.

B) LABEL PUMP ASSEMBLY WITH ITEM NAME. DRAWING NUMBER, SERIAL NUMBER, AND ACTUAL WEIGHTUSING 1/2" TO 3/4" HIGH CHARACTERS. COLOR SHALL BE BLACK ON YELLOW BACKGROUND.IDENI1FICA110N INFORMATION SHOULD BE READABLE FROM ABOVE IF POSSIBLE. DECALS OR PAINT AREACCEPTABLE.

C) PUMP ASSEMBLY (ITEM 1) SHALL BE WEIGHED WY M&TE. THIS WEIGHT (IN LBS) SHALL BE INDICATEDPER NOTE 9B.

10. FOR INSPECTION, TESTING AND SHIPPING OF THE PUMP ASSEMBLY. SEE SPECIFiCATION RPP-SPEC-62O12.

11. DESIGN PRESSURE OF THE PUMP ASSEMBLY IS 400 PSIG 0 1 80'F.

FLEXIBLE HOSE ASSEMBLY SHALL BE PROCURED IN ACCORDANCE WITH HOSE SPEC RPP-14859, CURRENT REVISION.

13. SEE RPP-CALC-83O15 FOR SUPERHATANT PUMP ASSEMBLY OPERATIONAL STRUCTURAL ANALYSIS. ANDRPP-CALC-63344 FOR UFI1NG ANALYSIS.

14. FOR ASME B31.3 ANALYSIS SEE RPP-CALC-62148.

H-2-9O185-020 NOZZLE: ASME SECTION IX PIOH MATERLAL

18. DISCHARGE PIPING (PRESSURE BOUNDARY) WHEN INSTALLED IS A CLASS I. DMSION I • GROUP B. HYDROGENHAZARDOUS LOCATIONS PER HNF-SD-WM-HC-017.

FOR ATEX EQUIVALENT SAFETY TECHNICAL EVALUATION FOR PIPING, PUREE CONNECTORS, AND THREADEDCONNECTIONS INCLUDING CHEM JOINTS, SEE RPP-TE-58251.

THE LOWER HYDRAULIC HOSES (ITEMS 57. 59. AND 60) SHALL HAVE FEMALE JIC SWIVEL ON BOTH ENDS. THE UPPERHYDRAUUC HOSES (ITEMS 53, 54, AND 55) SHALL HAVE 90 DEG ELBOW FEMALE JIC SWIVEL ON ONE END AND MALENET ON 11-IE OTHER END. END F1NGS SHALL MATCH HOSE SIZE. HOSES SHALL BE ASSEMBLED WITH QUICKDISCONNECTS (ITEMS 136, 137, OR 138 ACCORDING TO HOSE SIZE). ALL FIITINGS SHALL BE STEEL USEMANUFAC11JRER'S RECOMMENDED FITI1NGS. LENGTH OF HOSE SHALL BE MEASURED FROM THE FACE OF THE NUT ONTHE END F1TI1NG. PERFORM HYDROSTATIC PRESSURE TEST ON ASSEMBLED HOSES USING QUAKER QUINTOLUBRIC888-46 HYDRAUUC FLUID. TEST PRESSURE SHALL BE 6000 PSI (-0, +200 PSI), HOLD FOR A MINIMUM OF 30SECONDS AND A MAXIMUM OF 80 SECONDS. IN-PROCESS EXAMINATiON OF UPPER HYDRAUUC HOSE QUICKDISCONNECT FITTINGS IS ALLOWED. ACCEPTANCE CRITERIA IS NO LEAKS.

18. PUMP ASSEMBLY SHALL BE FULLY RETRACTED. I.E. IN THE UP POSITION. WHEN LIFTED FROM HORIZONTAL TOVERTICAL PRIOR TO AND FOLLOWING MOUNTING OF THE PUMP ONTO THE PUMP ASSEMBLY. PERFORM PERIODICPUMP ROTATION PER MANUFACTURER'S INSTRUCTIONS. RECORD AND SUBMIT MAJNTENANCE RECORDS.

TORQUE 3/4" PUMP MOUNTING BOLTS TO 63 FT-LBS. USE 3/4" CS HARDENED FLAT WASHERS AS REQUIRED UNDERTHE BOLT HEADS TO PREVENT BOLTS FROM BOTTOMING 01ff AGAJNST THE PLUGS INSTALLED IN THE TAPPED HOLES.MAINTAIN A MINIMUM OF 1" THREAD ENGAGEMENT ON ALL PUMP MOUNTING BOLTS. CLEAN AND DRY THREADS.APPLY RED LOCT1TE AT FINAL INSTALLATION.

[>. THE COMPONENT IS SAFElY SIGNIFICANT AND SHALL BE PURCHASED FROM AN EVALUATED SUPPLIER OR CGIDEDICATED PRIOR TO INSTALLATION. THE ITEM SHALL BE PERMANENTLY MARKED (SIZE PERMITTING) WITHPURCHASE ORDER NUMBER, DRAWING NUMBER & PARTS/MATERIAL LIST ITEM NUMBER. FABRICATOR SHALL SUBMIT"CMTR'S" FOR ALL SAFETY SIGNIFICANT MATERIALS. INCLUDING WELD FILLER MATERIAL. WHERE APPLICABLE. CNIR'SAND MARKING NOT REQUIRED FOR MALE NOZZLE (ITEM 31).

21. FOR MATERIAL COMPATIBILITY EVALUATION SEE RPP-RPT-6O770.

FABRICATE AND INSTALL HYDRAUUC JUMPER HOSE ASSEMBLY WHILE PUMP ASSEMBLY IS IN STORAGE TOALLOW FOR PERIODIC PUMP ROTATION.

f >. PROViDE A MINIMUM OF 50 FEET OF 4/C 14 AWG TYPE TC-ER CABLE FOR FIELD CONNECTION OF UMIT SWITCH.

WHEN NOT CONNECTED TO HYDRAULIC EXTENSION HOSE, CAP 3/4" UNE WITH DUST CAP (ITEM 139).

j >. THIS IS AN ASME B31 .3 ATTACHMENT WELD.

j >. MODIFIED WY REMOVING SPRING AND CHECK VALVE.

HEAT TRACE AND INSULATE THE HYDRAULIC HOSES AS A BUNDLE ABOVE THE PUMP FLANGE. SPIRALWRAP THE HOSES USING A 1.3:1 RATIO. INSTALL END SEAL KIT AT FLANGE END OF HOSES AND LEAVE5 FEET MINIMUM OF D<TRA HEAT TRACE AT WHIP END FOR FIELD SPLICING/CONNECTION. INSULATEUSING 2" CERAMIC FIBER. INSULATION DENSITY OF 8PCF, GRAY SIUCONE JACKETED INSULATiON. INSTALLPER MANUFACTURER'S INSTRUCTIONS. HEAT TRACE LABELS (RAYCHEM #ETL) SHALL BE INSTALLED ONOUTER INSULATION PER NEC 427.13. ROUTE SPEED SENSOR CABLE WITH HYDRAULIC HOSES. TO THEEXTENT POSSIBLE INSTALL SHRINK TUBE OR SHRINK WRAP (ITEM 142) WHERE POSSIBLE ANDAPPROXIMATELY TO END OF HOSES.

8 7 6

5 4 3

---

N

/[>. WIRE ROPE TO BE FROM A REPUTABLE MANUFACTURER (WIRECO. LOOS & CO., ETC.). MINIMUM BREAKING STRENGTH /

SHALL BE 15,900 LBS. MINIMUM WORKING LOAD LIMIT (WLL) SHALL BE BASED ON A 5:1 SAFETY FACTOR OF WIRE /ROPE BREAKING STRENGTH. THE MINIMUM WLL SHALL NOT BE LESS THAN 3,180 LBS. THE OPEN SWAGE SOCKETSHALL BE STAJNLESS STEEL (UPSON WALTON PART NUMBER 40043850 OR APPROVED EQUAL). LOAD TESTCOMPLETED ASSEMBLIES IN ACCORDANCE WITH ASME B3O.9. SUBMIT ALL TEST REPORTS.

ACTEK SWIVEL HOIST RING NOTES: IA. ALL SWIVEL HOIST RINGS SHALL BE AS MANUFACTURED WY ACTEK MANUFACTURING AND ENGINEERING INC.

INSTALL/RE-INSTALL THESE HOIST RINGS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS EXCEPT AS AMENDEDAND DOCUMENTED IN VENDOR INFORMATION FILE #VI-5O159. THE MANUFACTURER'S AMENDED INFORMATION AND/OROTHER RELEVANT INFORMATION IS DESCRIBED IN THE FOLLOWING NOTES. \

\B. ALL STEEL COMPONENTS ENGAGING THE HOIST RINGS SHALL HAVE MINIMUM TENSILE STRENGTHS OF 58,000 PSI.

C. ALL ACTEK HOIST RING SCREW THREADS ARE CLASS BA, THEREFORE. ALL TAPPED THREADS SHALL BE MATCHINGCLASS 2B.

D. PRIOR TO ITS USE, EACH HOIST RING SHALL BE TIGHTENED TO TORQUE VALUE AS SHOWN BELOW. PAINT TO BEAPPLIED FOLLOWING FINAL TORQUE.

I ACTEK I RATED LOAD TORQUEFI-LB IHOIST RING SCREW SIZE (LBS) I (±10%,1RART NUMBER

I 46206-C I 3/4-10 UNC I 7,000 I 100 I

E. IF "ANTI-SEIZE" LUBRICANT IS PRESENT IN THE THREADS OF THE HOIST RING SCREW OR IN THE TAPPED THREADS, ITMUST BE REMOVED WITH ACETONE OR ANOTHER VENDOR APPROVED SOLVENT.

F. INSPECTION OF HOIST RINGS SHALL MEET MANUFACTURER'S AND HANFORD SITE HOISTING AND RIGGING MANUAL(DOE-RL-92-36) REQUIREMENTS.

SUPERNATANT PUMP ASSEMBLYSCALE: 1/16

-AR-i

H-15-7 A-FARM WRS AP PIT MODELS

H-14-111014 DRAWING LIST & TITLE SHEET RELEASED PER EDT-882295

4750

5 4 3

\

/

2

2

U.S. DEPARTMENT OF ENERGYOffloo of RIVer Plotootloo

A-FARM RETRIEVALADJUSTABLE SN PUMP

GENERAL NOTES

FH-14-111O17 182 NONE

18220 1 O'O

F

E

C

H-14-111017 SH 001 Rev.00 9/29/2019 - 4:54 PM 1 of 1

Sep 29, 2019DATE: