Genesis - Genesis€¦ · Winter 120+ 248 x 248 x 163 10.03 2.75 Pharmapac-Genesis™ 5 2 - 8°C...
Transcript of Genesis - Genesis€¦ · Winter 120+ 248 x 248 x 163 10.03 2.75 Pharmapac-Genesis™ 5 2 - 8°C...
Genesis 3 – 4.37L to 6.70L 48 Hrs Minimum Summer Duration
Pharmapac-Genesis™ is Hydropac’s first validated offering within the Pharmapac brand, designed as a cost effective, single-use system to protect refrigerated payloads (2 – 8°C) for at least two days during transit.
Consisting of a heavy-duty recyclable polystyrene (EPS) container, robust ice packs and an innovative filter pack designed to regulate internal temperatures, Hydropac have been able to achieve superior year-round thermal protection minus the complexity and cost.
Simple, affordable, effective.
The science behind Pharmapac-Genesis’™ Filter Pack
Summer
Spring/Autumn
Winter
Another innovation by
• First layer of water absorbs the majority of the sub-zero thermal energy from the ice pack.
• Insulative panel controls the rate of cooling of the second layer of water to ensure sample temperatures do not deviate outside the 2 – 8°C temperature window.
Two layers of encapsulated water separated by an insulative panel
- Genesis™
2 - 8°C 0.75 – 14 L 48+ Hours Minimum
Pharmapac-Genesis™ is Hydropac’s first validated offering within the
Pharmapac brand, designed as a cost effective, single-use system to
protect refrigerated payloads (2 – 8°C) for at least two days during
transit.
Consisting of a heavy-duty recyclable polystyrene (EPS) container,
robust ice packs and an innovative filter pack designed to regulate
internal temperatures, Hydropac have been able to achieve superior
year-round thermal protection minus the complexity and cost.
Simple, affordable, effective.
Summer
Spring/Autumn
The science behind Pharmapac-Genesis’™ Filter Pack
Two layers of encapsulated water separated by an
insulative panel
• First layer of water absorbs the majority of the sub-zero thermal energy from the
ice pack.
• Insulative panel controls the rate of cooling of the second layer of water to ensure
sample temperatures do not deviate outside the 2 – 8°C temperature window.
System ID Season Duration (Hours)
Payload Dims. (mm)
L x W x H Litres
External Dims. (mm)
L x W x H
Tare Weight
(kg)
Pharmapac-Genesis™ 1
2 - 8°C
Summer 52 152 x 152 x 32 0.75
255 x 255 x 255
1.69
Spring/Autumn 75 152 x 152 x 65 1.50 1.25
Winter 120+ 152 x 152 x 72 1.66 1.25
Pharmapac-Genesis™ 3
2 - 8°C
Summer 58 248 x 208 x 71 4.37
355 x 305 x 300
3.30
Spring/Autumn 83 248 x 208 x 99 6.09 2.25
Winter 120+ 248 x 208 x 109 6.70 2.25
Pharmapac-Genesis™ 4
2 - 8°C
Summer 78 202 x 202 x 75 3.06
345 x 345 x 355
3.25
Spring/Autumn 106 202 x 202 x 108 4.41 2.30
Winter 120+ 202 x 202 x 119 4.86 2.30
Pharmapac-Genesis™ 4D
2 - 8°C
Summer 54 248 x 248 x 117 7.20
345 x 345 x 355
3.95
Spring/Autumn 76 248 x 248 x 151 9.29 2.75
Winter 120+ 248 x 248 x 163 10.03 2.75
Pharmapac-Genesis™ 5
2 - 8°C
Summer 82 298 x 298 x 118 10.48
460 x 460 x 390
5.96
Spring/Autumn 108 298 x 298 x 146 12.97 4.05
Winter 120+ 298 x 298 x 158 14.03 4.05
Winter
Another innovation by
Simplicity, Engineered Through Innovation, Not Imitation
- Genesis™
GENESIS 3 - Datasheet
UK Summer Profile – 58 Hours – Pharmapac-Genesis™ 3
UK Spring/Autumn Profile – 83 to 120+ Hours – Pharmapac-Genesis™ 3
UK Winter Profile – 120+ Hours – Pharmapac-Genesis™ 3
ISTA 7D Summer 24H Cycled – 40 Hours – Pharmapac-Genesis™ 3
ISTA 7E Winter 48H Cycled – 120+ Hours – Pharmapac-Genesis™ 3
ANFOR Summer 48H Cycled – 49 Hours – Pharmapac-Genesis™ 3
ANFOR Winter 48H Cycled – 120+ Hours – Pharmapac-Genesis™ 3
For more information, please contact:
[email protected] T: +44 (0) 1494 530 182 www.hydropac.co.uk
Hydropac Limited, Unit 1 Network 4, Lincoln Road, High Wycombe, Buckinghamshire, HP12 3RF
©2019 HYDROPAC all rights reserved.
0
5
10
15
20
25
30
35
0:00 12:00 24:00 36:00 48:00 60:00 72:00
0
5
10
15
20
25
0:00 24:00 48:00 72:00 96:00 120:00 144:00 168:00
Spring/Autumn Configuration - 1 Ice Pack Spring/Autumn Configuration - 2 Ice Packs
0
5
10
15
20
0:00 24:00 48:00 72:00 96:00 120:00 144:00 168:00 192:00 216:00 240:00Winter Configuration - 1 Ice Pack Winter Configuration - 2 Ice Packs
0
5
10
15
20
25
30
35
40
45
0:00 12:00 24:00 36:00 48:00
0
5
10
15
20
0:00 24:00 48:00 72:00 96:00 120:00 144:00 168:00 192:00 216:00 240:00Winter Configuration - 1 Ice Pack Winter Configuration - 2 Ice Packs
0
10
20
30
40
50
0:00 12:00 24:00 36:00 48:00 60:00
-5
0
5
10
15
20
0:00 24:00 48:00 72:00 96:00 120:00 144:00 168:00 192:00 216:00 240:00Winter Configuration - 1 Ice Pack Winter Configuration - 2 Ice Packs
Average Ambient Temperature: 20.34°C
Average Ambient Temperature: 6.95°C
Average Ambient Temperature: 30.33°C
Average Ambient Temperature: 25.70°C
Average Ambient Temperature: 7.46°C
Average Ambient Temperature: 6.67°C
Average Ambient Temperature: 11.42°C
Another innovation by For more information, please contact:[email protected] T: +44 (0) 1494 530 182 www.hydropac.co.ukHydropac Limited, Unit 1 Network 4, Lincoln Road, High Wycombe, Buckinghamshire, HP12 3RF
GENESIS 3 - Datasheet