General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets -...

26
General Sign Specification Manual - April 2013 General Sign Specification Manual This original artwork is protected under Federal Copyright Laws. Make no reproduction of this design concept without permission from Tube Art Group. Colors on print may not accurately depict specific colors. Yakima Office 2323 W. Washington Ave Yakima, WA 98902 509.469.8186 800.562.2854 Fax 509.469.8211 TUBE ART GROUP Spec Book

Transcript of General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets -...

Page 1: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

General Sign Specification Manual - April 2013

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 2: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration 4

B

3/16” red (ROHM & HASS#2157) acrylic letter faces.3/16” white acrylic logo face with 3M red (3630-33) vinyl .5” deep .040 stock red channel coil returns.1” stock solid red trim cap.Red LED illumination in letters.White LED illumination in logo.Exposed water proof (painted) raceway fabricatedfrom .090 aluminum. Paint color TBD.

Display to be approved by the National Electrical Code, Underwriters Laboratory,CUL and all applicable local codes.

Illuminated Channel Letters & Logo

A

B

C

E

D

12"

14"

16"

18"

20"

22"

24"

26"

28"

30"

32"

34"

14.50

19.80

25.85

33.57

41.31

51.04

60.00

70.33

81.61

94.79

106.70

120.09

25 5/8”

29 3/4”

34”

38 3/8”

42 1/2”

47 1/2"

50 3/4”

55”

59 3/8"

64”

68”

72 1/8”

8'-2 3/8”

9-7 3/8”

10'-11 1/4”

12'-4 1/2”

13'-8 1/2”

15'-1 1/2”

16'-4 5/8”

17'-9”

19'-1 1/2"

20'-7 1/2”

21'-10 3/8”

23'-3 1/4”

A B C SQ FTSIGN TYPE

DIMENSIONS

F

G

Channel Letter & Logo Side Detail (Raceway and flush mounted details)

Not To Scale

Channel Letter & Logo Side Detail (Raceway and flush mounted details)

Not To Scale

Channel Letter & Logo Front View (Raceway and flush mounted details)

D

A

D

CB C D A

G

B

A

D

CB C D A

12"

14"

16"

18"

20"

22"

24"

26"

28"

30"

32"

34"

Trimcap

.040" aluminum returns

.063" aluminum backs

3/16" acrylic

Led Power Supply

LEDs

Fasteners as required

5"8”

Disconnect Switch

Trimcap

.040" aluminum returns

.063" aluminum backs

3/16" acrylic

Led Power Supply

LEDs

Fasteners as required

5"

Disconnect Switch

Power Req.-120 v Power Req.-120 v

EE FF EE FFCC4L-12

CC4L-14

CC4L-16

CC4L-18

CC4L-20

CC4L-22

CC4L-24

CC4L-26

CC4L-28

CC4L-30

CC4L-32

CC4L-34

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 3: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Channel Letters

Scale: 1/8”=1’

Illuminated Channel Letter & Logo Sets - Stacked Non-Standard with Limited Square Footage Configuration 4Channel Letters

8’-2 3/8”

25 5/8”29 3/4”

9’-7 3/8”

10’-11 1/4”

38 3/8”

12’-4 1/2”

(14.50 sq.ft)(19.80 sq.ft)

(25.85 sq.ft)

(33.57 sq.ft)

42 1/2”20”

CC4-20

20”

13’-8 1/2”(41.31 sq.ft)

47 1/2”

15’-1 1/2”(51.04 sq.ft)

50 3/4”

16’-4 5/8”(60.00 sq.ft)

72 1/8”

CC4-34

34”

23’-3 1/4”(120.09 sq.ft)

CC4-32

32”

21’-10 3/8”(106.70 sq.ft)

64”

30”

20’-7 1/2”(94.79 sq.ft)

59 3/8”

19’-1 1/2”(81.61 sq.ft)

55”

17’-9”(70.33 sq.ft)

34”

32”

68”

CC4-30

30”

CC4-28

28”

28”

CC4-26

26”

26”

CC4-24

24”

24”

CC4-22

22”

22”

18”

CC4-18

18”

34”16”

CC4-16

16”

14”

CC4-14

14”12”

CC4-12

12”

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 4: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

(Lease Hold Area)EQ. EQ.

Center Line

Rear Service Door

Scale: 3/16”=1’

Example of Typical Sign Package - Channel Letters, Neon Open Display, Window and Service Door Graphics Stacked Non-Standard with Limited Square Footage Configuration 4

5’-0"Above

FinishedFloor

Store Front

Scale: 3/16”=1’

Delivery & Service Entrance

5’-0"Above

FinishedFloor

EQ.

EQ.

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

3’-0"Above

FinishedFloor

Page 5: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Standard Linear Configuration 2

3/16” red (ROHM & HASS#2157) acrylic letter faces.3/16” white acrylic logo face with 3M red (3630-33) vinyl .5” deep .040 stock red channel coil returns.1” stock solid red trim cap.Red LED illumination in letters.White LED illumination in logo.

Illuminated Channel Letters & Logo

A

B

C

E

D

Channel Letter & Logo Front View (Raceway and flush mounted details)

12"

11”

10”

12"12"

14"

16"

18"

20"

22"

24"

26"

28"

30"

32"

34"

15'-11 1/2”

14'-7 3/4”

13'-3 3/4”

18-7 1/2”

21’-3 1/2"

23'-11 1/2”

26'-7 1/2”

29'-3 1/2”

31'-11 1/2"

34'-8”

37’-3 1/2"

40’-0"

42'-7 1/2”

45'-3 1/2”

A BSIGN TYPE

DIMENSIONS

F

16.00

13.40

11.10

21.70

28.30

36.30

44.30

53.60

64.00

75.10

86.90

100.00

113.50

128.20

SQ FT

A

BB C D A G

A

BB C D A

Exposed water proof (painted) raceway fabricatedfrom .090 aluminum. Paint color TBD.

Display to be approved by the National Electrical Code, Underwriters Laboratory, CUL and all applicable local codes.

G

Channel Letter & Logo Side Detail (Raceway and flush mounted details)

Not To Scale

Channel Letter & Logo Side Detail (Raceway and flush mounted details)

Not To Scale

Trimcap

.040" aluminum returns

.063" aluminum backs

3/16" acrylic

Led Power Supply

LEDs

Fasteners as required

5"8”

Disconnect Switch

Trimcap

.040" aluminum returns

.063" aluminum backs

3/16" acrylic

Led Power Supply

LEDs

Fasteners as required

5"

Disconnect Switch

Power Req.-120 v Power Req.-120 v

EE FF EE FFCC2L-12

CC2L-11

CC2L-10

CC2L-14

CC2L-16

CC2L-18

CC2L-20

CC2L-22

CC2L-24

CC2L-26

CC2L-28

CC2L-30

CC2L-32

CC2L-34

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 6: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Standard Letter Sizes - Channel Letters Standard Linear Configuration 2

Channel Letters

Scale: 1/8”=1’

24"

31'-11 1/2"

22"

29'-3 1/2"

20"

26'-7 1/2"

18"

23'-11 1/2"

16"

21'-3 1/2"

14"

18'-7 1/2"

12"

15'-11 1/2"

26"

34'-8"

28"

37'-3 1/2"

30"

40'-0"

32"

42'-7 1/2"

34"

45'-3 1/2"

11"

14'-7 3/4"

10"

13'-3 3/4"

CC2-34

CC2-30

CC2-26

CC2-24

CC2-22

CC2-20

CC2-18

CC2-14

CC2-12

CC2-11

CC2-10

(128.20 sq.ft)

(100.0 sq.ft)

(86.90 sq.ft)

(75.10 sq.ft)

(64.00 sq.ft)

(113.50 sq.ft)

(53.60 sq.ft)

(44.30 sq.ft)

(36.30 sq.ft)

(28.30 sq.ft)

(21.70 sq.ft)

(16.00 sq.ft)

(13.40 sq.ft)

(11.10 sq.ft)

CC2-16

CC2-32

CC2-28

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 7: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

(Lease Hold Area)EQ. EQ.

Center Line

EQ.

EQ.

Rear Service Door

Scale: 3/16”=1’

Example of Typical Sign Package - Channel Letters, Neon Open Display, Window and Service Door Graphics Standard Linear Configuration 2

5’-0"Above

FinishedFloor

Store Front

Scale: 3/16”=1’

Delivery & Service Entrance

5’-0"Above

FinishedFloor

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

3’-0"Above

FinishedFloor

Page 8: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Standard Stacked Configuration 1

B

3/16” red (ROHM & HASS#2157) acrylic letter faces.3/16” white acrylic logo face with 3M red (3630-33) vinyl .5” deep .040 stock red channel coil returns.1” stock solid red trim cap.Red LED illumination in letters.White LED illumination in logo.Exposed water proof (painted) raceway fabricatedfrom .090 aluminum. Paint color TBD.

Display to be approved by the National Electrical Code, Underwriters Laboratory, CUL and all applicable local codes.

Illuminated Channel Letters & Logo

A

B

C

E

D

CC1L-12

CC1L-14

CC1L-16

CC1L-18

CC1L-20

CC1L-22

CC1L-24

CC1L-26

CC1L-28

CC1L-30

CC1L-32

CC1L-34

12"

14"

16"

18"

20"

22"

24"

26"

28"

30"

32"

34"

18.57

25.29

33.18

41.97

51.74

62.63

74.70

87.63

101.36

116.56

132.85

149.96

27"

31 1/2"

36"

40 1/2"

45"

49 1/2"

54"

58 1/2"

63"

67 1/2"

72"

76 1/2"

10'-11"

12-8 3/4"

14'-6 1/2"

16'-4 1/4"

18'-2 1/4"

20'-0"

21'-9 1/2"

23'-7 3/4"

25'-5 1/2"

27'-3 1/4"

29'-1 1/4"

30'-11"

A B C SQ FTSIGN TYPE

DIMENSIONS

B

A

A

C

F

G

C

A

A

B C

A

D

B C D

G

A

Channel Letter & Logo Front View (Raceway and flush mounted details)

Channel Letter & Logo Side Detail (Raceway and flush mounted details)

Not To Scale

Channel Letter & Logo Side Detail (Raceway and flush mounted details)

Not To Scale

Trimcap

.040" aluminum returns

.063" aluminum backs

3/16" acrylic

Led Power Supply

LEDs

Fasteners as required

5"8”

Disconnect Switch

Trimcap

.040" aluminum returns

.063" aluminum backs

3/16" acrylic

Led Power Supply

LEDs

Fasteners as required

5"

Disconnect Switch

Power Req.-120 v Power Req.-120 v

EE FF EE FF

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 9: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Standard Letter Sizes - Channel Letters Standard Stacked Configuration 1

67 1/2"

72"

76 1/2"

30"

30"

32"

32"

34"

34"

29'-1 1/4"

30'-11"

24"

24"

22"

22"

26"

26"

28"

28"

27"31 1/2"

36"

40 1/2"

45"

49 1/2"

54"

58 1/2"

63"

20'-0"

21'-9 1/2"

23'-7 3/4"

25'-5 1/2"

(149.64 sq.ft)

27'-3 1/4””(116.56 sq.ft)

(132.85 sq.ft)

(101.36 sq.ft)

(87.63 sq.ft)

20"

20"

18'-2 1/4"

18"

18"

16'-4 1/4"

16"

16"

14'-6 1/2"

14"

14"

12'-8 3/4"

12"12"

(74.70 sq.ft)

(62.63 sq.ft)

(51.74 sq.ft)

(41.97 sq.ft)

(33.18 sq.ft)

(25.29 sq.ft) 10'-11”(18.57 sq.ft)

CC1-34

CC1-32

CC1-28

CC1-26

CC1-24

CC1-22

CC1-20

CC1-18

CC1-16

CC1-14 CC1-12

CC1-30

Channel Letters

Scale: 1/8”=1’

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

24"10"10"

9'-2”(18.33 sq.ft)CC1-10

Page 10: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

(Lease Hold Area)EQ. EQ.

Center Line

EQ.

EQ.

Rear Service Door

Scale: 3/16”=1’

Example of Typical Sign Package - Channel Letters, Neon Open Display, Window and Service Door Graphics Standard Stack Configuration 1.

5’-0"Above

FinishedFloor

Store Front

Scale: 3/16”=1’

Delivery & Service Entrance

5’-0"Above

FinishedFloor

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

3’-0"Above

FinishedFloor

Page 11: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked with Tag Line Configuration 3

B

3/16” red (ROHM & HASS#2157) acrylic letter faces.3/16” white acrylic logo face with 3M red (3630-33) vinyl .5” deep .040 stock red channel coil returns.1” stock solid red trim cap.Red LED neon illumination in letters.White LED illumination in logo.Exposed water proof (painted) raceway fabricatedfrom .090 aluminum. Paint color TBD.1/4”black Sintra individual cut out letters on.090flat alum. carrier panel. Paint panel to matchfascia. Paint color TBD.

Display to be approved by the National Electrical Code, Underwriters Laboratory, CUL and all applicable local codes.

Illuminated Channel Letters & Logo

A

B

C

E

D

CC3L-12

CC3L-14

CC3L-16

CC3L-18

CC3L-20

CC3L-22

CC3L-24

CC3L-26

CC3L-28

CC3L-30

CC3L-32

CC3L-34

12"

14"

16"

18"

20"

22"

24"

26"

28"

30"

32"

34"

17.45

23.77

31.20

39.54

48.76

59.03

70.32

82.51

95.39

109.70

125.05

141.14

27"

31 1/2"

36"

40 1/2"

45"

49 1/2"

54"

58 1/2"

63"

67 1/2"

72"

76 1/2"

10'-11"

12-8 3/4"

14'-6 1/2"

16'-4 1/4"

18'-2 1/4"

20'-0"

21'-9 1/2"

23'-7 3/4"

25'-5 1/2"

27'-3 1/4"

29'-1 1/4"

30'-11"

A B C SQ FTSIGN TYPE

DIMENSIONS

B

A

D

C

F

G

C

B C D

B C D

G

A

Channel Letter & Logo Side Detail (Raceway and flush mounted details)

Not To Scale

Channel Letter & Logo Side Detail (Raceway and flush mounted details)

Not To Scale

Channel Letter & Logo Front View (Raceway and flush mounted details)

D E

9”

10 7/8"

12 3/8”

14"

15 1/2"

17”

18 5/8"

20 1/8"

21 3/4"

23 1/4"

24 5/8”

26'-3/8”

2 1/4”

2 5/8"

3”

3 3/8”

3 3/4”

4 1/8”

4 1/2"

4 7/8"

5 1/4"

5 5/8”

6”

6'-3/8”

EF A M I L Y H A I R S A L O N

F A M I L Y H A I R S A L O N

A

HH

H

A

D

E

Trimcap

.040" aluminum returns

.063" aluminum backs

3/16" acrylic

Led Power Supply

LEDs

Fasteners as required

5"8”

Disconnect Switch

Trimcap

.040" aluminum returns

.063" aluminum backs

3/16" acrylic

Led Power Supply

LEDs

Fasteners as required

5"

Disconnect Switch

Power Req.-120 v Power Req.-120 v

EE FF EE FF

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 12: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Standard Letter Sizes - Channel Letters Stacked with Tag Line Configuration 3

67 1/2"

72"

76 1/2"

23 1/4”

30"

24 5/8”

32"

26 3/8”

34"

29'-1 1/4"

30'-11"

18 5/8”

24"

17”

22"

20 1/8”

26"

21 3/4”

28"

27"31 1/2"

36"

40 1/2"

45"

49 1/2"

54"

58 1/2"

63"

20'-0"

21'-9 1/2"

23'-7 3/4"

25'-5 1/2"

(141.14 sq.ft)

27'-3 1/4””(109.70 sq.ft)

(125.05 sq.ft)

(95.39 sq.ft)

(82.51 sq.ft)

15 1/2”

20"

18'-2 1/4"

14”

18"

16'-4 1/4"

12 3/8”

16"

14'-6 1/2"

10 7/8”14"

12'-8 3/4"

9 1/4”12"

(70.32 sq.ft)

(59.03 sq.ft)

(48.76 sq.ft)

(39.54 sq.ft)

(31.20 sq.ft)

(23.77 sq.ft)10'-11”(17.45 sq.ft)

CC3-34

CC3-32

CC3-28

CC3-26

CC3-24

CC3-22

CC3-20

CC3-18

CC3-16

CC3-14CC3-12

CC3-30

Channel Letters

Scale: 1/8”=1’

F A M I L Y H A I R S A L O N 6 3/8”

F A M I L Y H A I R S A L O N 6”

F A M I L Y H A I R S A L O N 5 5/8”

F A M I L Y H A I R S A L O N 5 1/4”

F A M I L Y H A I R S A L O N 4 7/8”

F A M I L Y H A I R S A L O N 4 1/2”

F A M I L Y H A I R S A L O N 4 1/8”

F A M I L Y H A I R S A L O N 3 3/4”

F A M I L Y H A I R S A L O N 3 3/8”

F A M I L Y H A I R S A L O N 3”

2 5/8”F A M I L Y H A I R S A L O N F A M I L Y H A I R S A L O N

2 1/4”

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 13: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

(Lease Hold Area)EQ. EQ.

Center Line

Rear Service Door

Scale: 3/16”=1’

Example of Typical Sign Package - Channel Letters, Neon Open Display, Window and Service Door Graphics Stacked with Tag Line Configuration 3

5’-0"Above

FinishedFloor

Store Front

Scale: 3/16”=1’

Delivery & Service Entrance

5’-0"Above

FinishedFloor

F A M I L Y H A I R S A L O N

EQ.

EQ.

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

3’-0"Above

FinishedFloor

Page 14: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Illuminated LED Channel Letter - Raceway & Flush Mount Stacked without Logo Configuration 5

B

3/16” red (ROHM & HASS#2157) acrylic letter faces.5” deep .040 stock red channel coil returns.1” stock solid red trim cap.Red LED illumination in letters.Exposed water proof (painted) raceway fabricatedfrom .090 aluminum. Paint color TBD.

Display to be approved by the National Electrical Code, Underwriters Laboratory, CUL and all applicable local codes.

Illuminated Channel Letters & Logo

A

B

C

E

D

12"

14"

16"

18"

20"

22"

24"

26"

28"

30"

32"

34"

14.44

18.43

24.24

30.67

37.82

45.86

53.40

63.93

74.00

84.98

96.96

109.18

27"

31 1/2"

36"

40 1/2"

45"

49 1/2"

54"

58 1/2"

63"

67 1/2"

72"

76 1/2"

8'-2 1/8”

9’-6 1/2"

10’-10 7/8”

12'-3 1/8”

13'-7 1/2”

15’-0"

16'-4 1/4”

17'-8 5/8”

19'-1”

20'-5 5/8”

21'-9 5/8”

23'-2”

A B C SQ FTSIGN TYPE

DIMENSIONS

A

A

C

E

Channel Letter Front View (Raceway and flush mounted details)

Channel Letter Side Detail (Raceway and flush mounted details)

Not To Scale

B CA

B

A

A

C B CA

Trimcap

.040" aluminum returns

.063" aluminum backs

3/16" acrylic

Led Power Supply

LEDs

Fasteners as required

5"8”

Disconnect Switch

Trimcap

.040" aluminum returns

.063" aluminum backs

3/16" acrylic

Led Power Supply

LEDs

Fasteners as required

5"

Disconnect Switch

Power Req.-120 v Power Req.-120 v

D DCC5L-12

CC5L-14

CC5L-16

CC5L-18

CC5L-20

CC5L-22

CC5L-24

CC5L-26

CC5L-28

CC5L-30

CC5L-32

CC5L-34

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 15: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Standard Letter Sizes - Channel Letters Standard Stacked without Logo Configuration 5

67 1/2"

72"

76 1/2"

30"

30"

32"

32"

34"

34"

21'-9 5/8”

23'-2”

24"

24"

22"

22"

26"

26"

28"

28"

27"31 1/2"

36"

40 1/2"

45"

49 1/2"

54"

58 1/2"

63"

15’-0"

16'-4 1/4"

17'-8 5/8”

19'-1”

(109.18 sq.ft)

20'-5 5/8”(84.98 sq.ft)

(96.96 sq.ft)

(74.00 sq.ft)

(63.93 sq.ft)

20"

20"

13'-7 1/2”

18"

18"

12'-3 1/8”

16"

16"

10'-10 7/8”

14"

14"

9'-6 1/2"

12"12"

(53.40 sq.ft)

(45.86 sq.ft)

(37.82 sq.ft)

(30.67 sq.ft)

(24.24 sq.ft)

(18.43 sq.ft) 8'-2 1/8”(14.44 sq.ft)

CC5-34

CC5-32

CC5-28

CC5-26

CC5-24

CC5-22

CC5-20

CC5-18

CC5-16

CC5-14 CC5-12

CC5-30

Channel Letters

Scale: 1/8”=1’

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 16: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

(Lease Hold Area)EQ. EQ.

Center Line

Rear Service Door

Scale: 3/16”=1’

Example of Typical Sign Package - Channel Letters, Neon Open Display, Window and Service Door Graphics Stacked without Logo Configuration 5

5’-0"Above

FinishedFloor

Store Front

Scale: 3/16”=1’

Delivery & Service Entrance

5’-0"Above

FinishedFloor

EQ.

EQ.

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

3’-0"Above

FinishedFloor

Page 17: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Illuminated LED Channel Letter - Raceway & Flush Mount Standard Linear without Logo Configuration 6

Channel Letter Front View (Raceway and flush mounted details)

12"

11”

10”

12"12"

14"

16"

18"

20"

22"

24"

26"

28"

30"

32"

34"

34’-4 3/8”

36'-7 3/4”

38'-11 1/4”

32’-3/4”

29’-9 3/8”

27’ -5 7/8”

25'-2 3/8”

22'-10 7/8”

20’-7 3/8”

18'-4”

16’-1/2”

13’-9"

12’-7 1/8”

11’-5 1/2”

A BSIGN TYPE

DIMENSIONS

88.62

101.15

114.09

77.28

66.68

56.88

47.60

39.38

31.94

25.28

19.23

14.15

11.83

9.84

SQ FT

A

BA B C E

Channel Letter Side Detail (Raceway and flush mounted details)

Not To Scale

3/16” red (ROHM & HASS#2157) acrylic letter faces.5” deep .040 stock red channel coil returns.1” stock solid red trim cap.Red LED illumination in letters.Exposed water proof (painted) raceway fabricatedfrom .090 aluminum. Paint color TBD.

Illuminated Channel Letters & Logo

A

B

C

E

D

Display to be approved by the National Electrical Code, Underwriters Laboratory, CUL and all applicable local codes.

A

BA B C

Trimcap

.040" aluminum returns

.063" aluminum backs

3/16" acrylic

Led Power Supply

LEDs

Fasteners as required

5"8”

Disconnect Switch

Trimcap

.040" aluminum returns

.063" aluminum backs

3/16" acrylic

Led Power Supply

LEDs

Fasteners as required

5"

Disconnect Switch

Power Req.-120 v Power Req.-120 v

D DCC6L-12

CC6L-11

CC6L-10

CC6L-14

CC6L-16

CC6L-18

CC6L-20

CC6L-22

CC6L-24

CC6L-26

CC6L-28

CC6L-30

CC6L-32

CC6L-34

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 18: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Standard Letter Sizes - Channel Letters Standard Linear without Logo Configuration 6

24"

27'-5 7/8”

22"

25’-2 3/8"

20"

22'-10 7/8”

18"

20'-7 3/8"

16"

18’-4"

14"

16’- 1/2"

12"

13'-9”

26"

29'-9 3/8”

28"

32'-3/4"

30"

34’-4 3/8”

32"

36'-7 3/4”

34"

38’-11 1/4”

11"

12'-7 1/8”

10"

11'-5 1/2"

CC6-34

CC6-30

CC6-26

CC6-24

CC6-22

CC6-20

CC6-18

CC6-14

CC6-12

CC6-11

CC6-10

(114.09 sq.ft)

(88.62 sq.ft)

(77.28 sq.ft)

(66.68 sq.ft)

(56.88 sq.ft)

(101.15 sq.ft)

(47.60 sq.ft)

(39.38 sq.ft)

(31.94 sq.ft)

(25.28 sq.ft)

(19.23 sq.ft)

(14.15 sq.ft)

(11.83 sq.ft)

(9.84 sq.ft)

CC6-16

CC6-32

CC6-28

Channel Letters

Scale: 1/8”=1’

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 19: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

(Lease Hold Area)EQ. EQ.

Center Line

Rear Service Door

Scale: 3/16”=1’

Example of Typical Sign Package - Channel Letters, Neon Open Display, Window and Service Door Graphics Linear without Logo Configuration 6

5’-0"Above

FinishedFloor

Store Front

Scale: 3/16”=1’

Delivery & Service Entrance

5’-0"Above

FinishedFloor

EQ.

EQ.

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

3’-0"Above

FinishedFloor

Page 20: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

B

12"

14"

16"

18"

20"

22"

24"

26"

28"

30"

32"

34"

12.39

16.91

22.26

28.19

34.78

42.06

50.16

58.44

67.94

78.21

89.17

100.57

27"

31 1/2"

36"

40 1/2"

45"

49 1/2"

54"

58 1/2"

63"

67 1/2"

72"

76 1/2"

A B C SQ FTSIGN TYPE

DIMENSIONS

A

D

CB C

E

A

Channel Letter Side Detail (Raceway and flush mounted details)

Not To Scale

Channel Letter Front View (Raceway and flush mounted details)

D E

9 1/4”

10 7/8"

12 3/8”

14"

15 1/2"

17”

18 5/8"

20 1/8"

21 3/4"

23 1/4"

24 5/8”

26'-3/8”

2 1/4”

2 5/8"

3”

3 3/8”

3 3/4”

4 1/8”

4 1/2"

4 7/8"

5 1/4"

5 5/8”

6”

6'-3/8”

EF A M I L Y H A I R S A L O N

F

Illuminated LED Channel Letter - Raceway & Flush Mount Stacked without Logo Configuration 7

3/16” red (ROHM & HASS#2157) acrylic letter faces.5” deep .040 stock red channel coil returns.1” stock solid red trim cap.Red lLED illumination in letters.Exposed water proof (painted) raceway fabricatedfrom .090 aluminum. Paint color TBD.1/4”black Sintra individual cut out letters on.090flat alum. carrier panel. Paint panel to matchfascia. Paint color TBD.

Display to be approved by the National Electrical Code, Underwriters Laboratory, CUL and all applicable local codes.

Illuminated Channel Letters & Logo

A

B

C

E

D

F

B

A

D

CB CA

EF A M I L Y H A I R S A L O N

F

8'-2 1/8”

9’-6 1/2"

10’-10 7/8”

12'-3 1/8”

13'-7 1/2”

15’-0"

16'-4 1/4”

17'-8 5/8”

19'-1”

20'-5 5/8”

21'-9 5/8”

23'-2”

Trimcap

.040" aluminum returns

.063" aluminum backs

3/16" acrylic

Led Power Supply

LEDs

Fasteners as required

5"8”

Disconnect Switch

Trimcap

.040" aluminum returns

.063" aluminum backs

3/16" acrylic

Led Power Supply

LEDs

Fasteners as required

5"

Disconnect Switch

Power Req.-120 v Power Req.-120 v

D DCC7L-12

CC7L-14

CC7L-16

CC7L-18

CC7L-20

CC7L-22

CC7L-24

CC7L-26

CC7L-28

CC7L-30

CC7L-32

CC7L-34

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 21: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Standard Letter Sizes - Channel Letters Standard Stacked with Tag Line and no Logo Configuration 7

67 1/2"

72"

76 1/2"

23 1/4”

30"

24 5/8”

32"

26 3/8”

34"

18 5/8”

24"

17”

22"

20 1/8”

26"

21 3/4”

28"

27"31 1/2"

36"

40 1/2"

45"

49 1/2"

54"

58 1/2"

63"

(100.57 sq.ft)

(78.21 sq.ft)

(89.17 sq.ft)

(67.94 sq.ft)

(58.44 sq.ft)

15 1/2”

20"

14”

18"

12 3/8”

16"

10 7/8”14"

9 1/4”12"

(50.16 sq.ft)

(42.06 sq.ft)

(34.78 sq.ft)

(28.19 sq.ft)

(22.26 sq.ft)

(16.91 sq.ft)(12.39 sq.ft)

CC7-34

CC7-32

CC7-28

CC7-26

CC7-24

CC7-22

CC7-20

CC7-18

CC7-16

CC7-14CC7-12

CC7-30

Channel Letters

Scale: 1/8”=1’

F A M I L Y H A I R S A L O N 6 3/8”

F A M I L Y H A I R S A L O N 6”

F A M I L Y H A I R S A L O N 5 5/8”

F A M I L Y H A I R S A L O N 5 1/4”

F A M I L Y H A I R S A L O N 4 7/8”

F A M I L Y H A I R S A L O N 4 1/2”

F A M I L Y H A I R S A L O N 4 1/8”

F A M I L Y H A I R S A L O N 3 3/4”

F A M I L Y H A I R S A L O N 3 3/8”

F A M I L Y H A I R S A L O N 3”

2 5/8”F A M I L Y H A I R S A L O N F A M I L Y H A I R S A L O N

2 1/4”

21'-9 5/8”

23'-2”

17'-8 5/8”

19'-1”

20'-5 5/8”

15’-0"

16'-4 1/4"

13'-7 1/2”

12'-3 1/8”

10'-10 7/8”

9'-6 1/2"8'-2 1/8”

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 22: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

(Lease Hold Area)EQ. EQ.

Center Line

Rear Service Door

Scale: 3/16”=1’

Example of Typical Sign Package - Channel Letters, Neon Open Display, Window and Service Door Graphics Stacked with Tag Line and no Logo Configuration 7

5’-0"Above

FinishedFloor

Store Front

Scale: 3/16”=1’

Delivery & Service Entrance

5’-0"Above

FinishedFloor

F A M I L Y H A I R S A L O N

EQ.

EQ.

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

3’-0"Above

FinishedFloor

Page 23: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Tenant Panel Graphics - Vinyl Graphics For Monument & Pylon Displays

3m Tomato Red (3630-43) vinyl decoration.

Pylon Tenant Graphics

Scale: 1”=1’

Standard Stacked Configuration

Graphics applied to white tenant panel backgrounds as required.

Sizes to vary depending on individual locations.

EQ

EQ

EQ

EQ

3m Tomato Red (3630-43) vinyl decoration.

Pylon Tenant Graphics

Scale: 1”=1’

Standard Stacked Configuration

Graphics applied to white tenant panel backgrounds as required.

Sizes to vary depending on individual locations.

3m Tomato Red (3630-43) vinyl decoration.

Pylon Tenant Graphics

Scale: 1”=1’

Standard Linear Configuration

Graphics applied to white tenant panel backgrounds as required.

Sizes to vary depending on individual locations.

EQ

EQ

EQ

EQ

3m Tomato Red (3630-43) vinyl decoration.

Pylon Tenant Graphics

Scale: 1”=1’

Standard Linear Configuration

Graphics applied to white tenant panel backgrounds as required.

Sizes to vary depending on individual locations.

EQ

EQ

EQ

EQ

EQ

EQ

EQ

EQ

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 24: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Store Front Door Graphics

Scale: 1”=1’

Rear Service Door Graphic

Scale: 1”=1’

23”

7”

Store Front Entrance Door Graphics-

Scale: 3/8”=1’

(Sample Layout Only)

21"

Manufacture & install qty. of ( ) first surface front glass door vinyl logo and text.

X

Manufacture & install qty. of ( ) first surface service door vinyl graphic.

X

Rear Service Door Graphic

Scale: 3/8”=1’

M-F: 0:00-0:00SAT: 0:00-0:00SUN: 00:00-0:00

12"

*Actual Store Hours Required

Store Front Window Bands

Scale: 1/2”=1’

58”

72”

*Large Windows: 59” to 72”

2”6”

2”6”

*Small: 30” to 58” windows

27.25”

27 1/4” 27 1/4”2”

30”

*Blanks: up to 30” windows

26” qty ( ) bandsX

qty ( ) bandsX

qty ( ) bandsX

Manufacture and install a total of ( ) first surface opaque red & white window bands.

X

Apply graphic band to center of window, trim ends as needed.Top of graphic band to be at 3’-0” above finished floor (AFF).Tomato Red (7725-13) and White.

5’-0

” ab

ove

fini

shed

flo

or (

AFF

)

3’-0

” ab

ove

fini

shed

fl

oor

(AFF

)

5’-0

” ab

ove

fini

shed

flo

or (

AFF

)

Digitally printed graphics on opaque White vinyl.Colors to be Tom. Red (7725-13) and Black.Bottom of graphics applied to service doorat 5’ (feet) above finished floor (AFF).

1”4

1/4”

1”

Tom. Red (7725-13) and White opaque vinyl.Bottom of “COST CUTTERS” logo to be applied at 5’ (feet) above finished floor (AFF).

Store Front Door Graphics

Scale: 1”=1’

21"

Manufacture & install qty. of ( ) first surface front glass door vinyl logo and text.

X

6"

1”4

1/4”

Tom. Red (7725-13) and White opaque vinyl.Bottom of “COST CUTTERS” logo to be applied at 5’ (feet) above finished floor (AFF).

(double doors, left side door)

Page 25: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Non-Illuminated Letter Sets - Flush Mount Standard Linear and Stacked Configurations

Letter Front View (flush mounted details)

Scale: 1/2”=1’

15’-11 1/2”

Letter Side Detail (flush mounted details)

Not To Scale

1”Thick Letters

Routed Sintra letter/logo

Wall fascia

All Thread Mounting studs

1” thick non-Illuminated cut out letters flush mounted to interior face(s)

1” thick white Sintra (Celtec) painted routed interior flat letters.

“Cost Cutters” paint match to: 3M Red 3630-33 (Gloss paint)

“Logo” paint match to: 3M Red 3630-33 (Gloss paint)

with white vinyl overlay.

Letters to be backed with 1/4” Self-Locking Tee Nuts (part #93766a200)

All Thread studs with clear silicone sealant.

CCNIS-24

CCNIL-12

1’-0”

9’-7”

2’-0”

1/4” Self Locking T-Nuts

General Sign Specification Manual

This original artwork is protected

under Federal Copyright Laws.

Make no reproduction of this

design concept without permission

from Tube Art Group.

Colors on print may not accurately

depict specific colors.

Yakima Office

2323 W. Washington Ave

Yakima, WA 98902

509.469.8186

800.562.2854

Fax 509.469.8211TUBE ART GROUP S

pec

Boo

k

Page 26: General Sign Specification Manual - April 2013 · Illuminated LED Channel Letter & Logo Sets - Raceway & Flush Mount Stacked Non-Standard with Limited Square Footage Configuration

Ya

kim

a O

ffic

e

Yakim

a, W

A 9

8902

509.4

69.8

186

800.5

62.2

854

Fax

509.4

69.8

211

TU

BE

AR

T G

RO

UP

CA

TAL

OG

- A

pril

2013