GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from...

22
GEIA-STD-0007 Rev B OmegaPS 0007

Transcript of GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from...

Page 1: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

GEIA-STD-0007 Rev B

OmegaPS 0007

Page 2: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

2

Outline

• OmegaPS R18.1 Release

• Summary of Changes from MIL-STD-1388-2B

• SAE and Rev C

8/27/2012 Supportability Standards - Graham Brum

Page 3: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

3

OmegaPS R18.1 Release• R18.1 is the first OmegaPS release to

include a GEIA-STD-0007 application• The list of applications now includes

DEF-STAN 00-60 – Issue 0 to Issue 4 MIL-STD 1388-2B DEF AUST 5692 – Issue 1 and Issue 2 GEIA-0007 – Rev B

• Access to each Application is controlled by a key code and then by Team/Application access control

8/27/2012 Supportability Standards - Graham Brum

Login is through a separate URL. GUI is as per other core Applications.

Page 4: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

4

GEIA-STD-0007 Differences

• The large majority of the 0007 application is drawn directly from the MIL-STD-1388 application

• However – key differences make it impossible to move between the two applications seamlessly – data sets can be moved from 1388 to 0007 but not the reverse

8/27/2012

Page 5: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

5

GEIA-STD-0007 Differences

• ALC – ALCs are Alphanumeric• This improves flexibility and

allows for an auditable record of changes required through extended in-service management

8/27/2012

Page 6: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

6

GEIA-STD-0007 Differences

• Enables capture of Digital Files Enables data storage for IETMs or

direct publications – Illustrated Parts CFTO is using this capability in DND configuration

All data types supported thus could store video as required

Completely enables Initial Provisioning process in DND by storing SPTD for IP Conferences

8/27/2012

Links appear here when a file has been associated with a Project.

LCN and Provisioning Links are enabled currently for DND configuration of OmegaPS.

Add Document adds an item to the Library, Drop Document removes it, Show Document opens the file

Page 7: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

7

GEIA-STD-0007 Differences

• Enables three tiered maintenance definition – procedure/task/subtask

• Enables good map to SAP and excellent flexibility for creating maintenance documentation

Task

Sub-Task

Procedure

Task

Sub-Task

MIL-STD-1388

GEIA-STD-0007

Page 8: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

8

GEIA-STD-0007 Differences • Enables all task resources at the Subtask

level This capability was introduced to Omega as

an optional setting for the 1388 application several years ago and is consistent with DEF STAN 0060

It allows for work scheduling and better mapping to S1000D

8/27/2012

Resources – Personnel, Support Equipment, Provisioned Items, Manuals

Page 9: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

9

GEIA-STD-0007 Differences • All Narratines have been increased to

unlimited length The restrictions imposed by 1388 have all

been removed Narratives now exist for:

8/27/2012

• Skills• Test Equipment• Support Equipment Recommendation Data Revision Remarks• Facilities• Provisioning Remark• Parts Manual Provisioning Nomenclature• Personnel Requirement• System Re-Design

• Logistics Considerations• RAM Characteristics• Failure Mode Mission Phase Characteristics• FMEA Narrative• System/End Item Narrative• Additional Requirements• Unit Under Test Explanation• Electrical Ground• Transported End Item• Transportation

Page 10: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

10

GEIA-STD-0007 Differences • Additional Reliability requirements

Required Mean Time Between Effective (or Essential) Functional Failure Loss of mission essential function

Required Mean Time Between Non-Effective (or Non-Essential) Functional FailureLoss of non-mission essential function

Required Mean Time Between System Aborts

8/27/2012

Page 11: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

11

GEIA-STD-0007 Differences • Additional Sub-Task Work Area Code

Work Area Code Access Access Code identifying points of access for

maintenance – equates to S1000D Access

Work Area Code Zone Code identifying where the work will occur –

equates to S1000D Zone

8/27/2012

Page 12: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

12

GEIA-STD-0007 Differences • Sub-Task Objective States

List of conditions required to complete a subtaskList is drawn from S1000D

8/27/2012

Page 13: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

13

GEIA-STD-0007 Differences • Circuit Breaker Identification and State

Groups and States required to complete a sub-taskList is drawn from S1000D

8/27/2012

Page 14: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

14

GEIA-STD-0007 Differences • Scheduled Maintenance Events

Defines dependencies for maintenance tasksIn compliance with S1000D

8/27/2012

Trigger may be a condition or another task

Page 15: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

15

GEIA-STD-0007 Differences • Scheduled Maintenance Sampling

Defines when a task is to be completed on only a portion of the fielded itemsIn compliance with S1000D

8/27/2012

Page 16: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

16

GEIA-STD-0007 Differences • Additional NSNs

Allows for the identification of additional applicable NSNThis requirement was a result of experience

gained from CGCS and DRMIS

8/27/2012

When the original HA Reference is a specification rather than a MPN then actual MPNs can be added here associated with the applicable NSN

Page 17: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

17

SAE and Rev C• The Society of Automotive Engineers

absorbed TechAmerica in the June of 2013 Therefore the LCLS committee responsible

for GEIA-STD-0007 is now an SAE committee with the Aerospace and Defence Group

SAE committees rules do not require SAE membership in order to be a voting memberSAE wants a well balanced voting group

8/27/2012

Page 18: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

18

SAE and Rev C• Rev C is being planned for 2015

Items Pennant has submitted for consideration for Rev C are as followsRemove the LCN – no inherent value added –

only impediment would be any legacy requirement within the DoD data/solution map

Replace the Task Code with a non intelligent identifier and explicitly store all hidden attributes – adjust any DoD required reports.  This will also give us an opportunity to identify any changes required to these Task identification attributes

8/27/2012

Page 19: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

19

SAE and Rev C• Rev C is being planned for 2015

Items Pennant has submitted for consideration for Rev C are as followsAdd all data that only exists in LSA Report to be

held in the database – any sums, calculations, etc.  This will have the impact of moving us away from the reports and allow us to provide data.

Identify any S2000M data elements that should be added to Material identification

8/27/2012

Page 20: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

20

SAE and Rev C• Rev C is being planned for 2015

Items Pennant has submitted for consideration for Rev C are as followsIdentify any S3000L data elements that should

be added – probably As Design/As Delivered with Configuration Management and Serialization comes in with this – to me the cut off is As Designed then As Delivered allowing us to ID serial numbers delivered by Part #/Assembly

Identify any S5000F data elements that should be added

8/27/2012

Page 21: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

21

SAE and Rev C• Rev C is being planned for 2015

Items Pennant has submitted for consideration for Rev C are as followsIdentify standard interface requirements to

receive data from Engineering systems and provide data to Maintenance Management Systems/Material Management Systems

8/27/2012

Page 22: GEIA-STD-0007 Rev B OmegaPS 0007. Outline OmegaPS R18.1 Release Summary of Changes from MIL-STD-1388- 2B SAE and Rev C 8/27/20122Supportability Standards.

228/27/2012

Questions?