G-ULTRA WIRING DIAGRAMS
GSM DEVICES
Centurion Systems (Pty) Ltd www.centsys.com
G-ULTRA
D-Series Controller
Possible Activations
• Trigger Open• Pedestrian Open• Free Exit / Keep Open• Holiday Lock
Possible Notifi cations
• Gate Open / Closed• Gate Opening / Closing• Gate Standing Open• Mains Failure• Battery Low• Multiple Collisions
RELAY 1
LCK
+1
2V
CO
M
STA
TUS
FRX
PED
TRG
RELAY 2
GND IO1 IO2 IO3 IO4 NO NOCOM COMNC NC VDC
1. Wiring a G-ULTRA into a D-Series Controller
FIGURE 1
IN1GATEDATGND
+
+12
+ -- KEYPADSIRENSTROBE16VAC
2. Wiring a G-ULTRA into an Electric Fence Controller
FIGURE 2
G-ULTRA RELAY 1 RELAY 2
GND IO1 IO2 IO3 IO4 NO NOCOM COMNC NC VDC
Possible Activations
• Arm / Disarm
To program the Strobe to Status:
JVA Keypad, Press:1. “INSTALLER PIN”*0#2. 2202#3. *#
Nemtek Keypad, Press:1. “INSTALLER PIN”*0#2. 101# OR 0011# (Model Dependant)3. *#
• The Status and alarm inputs must have three seconds fi lter time confi gured on the G-UTRA
• The strobe output on the energiser needs to be programmed for the armed status notifi cation to be sent via the G-ULTRA
• Using “IN1” via the G-ULTRA will bypass the key-switch function on the energiser
Possible Notifi cations
• Arm Status• Alarm Notifi cations
Electric Fence control board
GND
+12VDC
NONO CO
M
++ --
NC
SirenRelay
StrobeRelay
NC
KEY
SW
ITCH
KEY
SW
ITCH
ALA
RM
STA
TUS
Z1GND C
3. Wiring a G-ULTRA into an Alarm System
FIGURE 3
G-ULTRA RELAY 1 RELAY 2
GND IO1 IO2 IO3 IO4 NO NOCOM COMNC NC VDC
Possible Activations
• Arm / Disarm
Alarm programming:
PGM1: Armed StatusPGM2: Siren FollowZ1: Keyswitch Latched Arm / Disarm
Possible Notifi cations
• Arm Status• Intruder / Siren
Alarm Panel
GND
+12VDC
KEY
SW
ITCH
KEY
SW
ITCH
GN
D
ALA
RM
STA
TUS
The Alarm Panel PGMs must activate to “GND”. However, if the Alarm Panel only supports positive activations, then relays must be used between the Alarm Panel and the G-ULTRA to change the activation to “GND”.
G-ULTRA
External pull-down resistor (10kΩ)
D-Series Controller
Possible Activations
• Trigger Open
Possible Notifi cations
• Gate Open / Closed• Gate Opening / Closing• Gate Standing Open• Mains Failure• Battery Low• Multiple Collisions
RELAY 1 RELAY 2
GND IO1 IO2 IO3 IO4 NO NOCOM COMNC NC VDC
4. Wiring a G-ULTRA into a D-Series Controller via a WiZo
FIGURE 4
WiZo
WiZo
IN
IN
NO
NO
COM
COM
NC
NC
GND
10k
+12VDC
TRG
TRG
GA
TES
TATU
S
GA
TES
TATU
S
IN1GATEDATGND
+
+12
+ -- KEYPADSIRENSTROBE16VAC
5. Wiring a G-ULTRA into an Electric Fence Controller via WiZos
FIGURE 5
G-ULTRA RELAY 1 RELAY 2
GND IO1 IO2 IO3 IO4 NO NOCOM COMNC NC VDC
Possible Activations
• Arm / Disarm
To program the Strobe to Status:
JVA Keypad, Press:1. “INSTALLER PIN”*0#2. 2202#3. *#
Nemtek Keypad, Press:1. “INSTALLER PIN”*0#2. 101# OR 0011# (Model Dependant) 3. *#
Possible Notifi cations
• Arm Status• Alarm Notifi cations
G-ULTRA
Electric Fence control board
GND
+12VDC
WiZo WiZo
WiZo WiZo
IN IN
IN IN
NO NO
NO NO
COM COM
COM COM
NC NC
NC NCNONO CO
M
++ --
NCNC
GND+12VDC
KEYSWITCH
KEYSWITCH
ALARM
STATUS
STA
TUS
ALARM
• The Status and alarm inputs must have three seconds fi lter time confi gured on the G-ULTRA
• The strobe output on the energiser needs to be programmed for the armed status notifi cation to be sent via the G-ULTRA
• Using “IN1” via the G-ULTRA will bypass the key-switch function on the energiser
Z1GND C
6. Wiring a G-ULTRA into an Alarm System via WiZos
FIGURE 6
G-ULTRA RELAY 1 RELAY 2
GND IO1 IO2 IO3 IO4 NO NOCOM COMNC NC VDC
Possible Activations
• Arm / Disarm
Alarm programming:
PGM1: Armed StatusPGM2: Siren FollowZ1: Keyswitch Latched Arm / Disarm
Possible Notifi cations
• Arm Status• Intruder / Siren
Alarm Panel
GND
+12VDC
WiZo
WiZo
IN
IN
NO
NO
COM
COM
NC
NC
WiZo
INNOCOMNC
WiZo
INNOCOMNC
KEY
SW
ITCH
KEY
SW
ITCH
ALA
RM
ALA
RM
GN
D
STA
TUS
STA
TUS
GND+12VDC
The Alarm Panel PGMs must activate to “GND”. However, if the Alarm Panel only supports positive activations, then relays must be used between the Alarm Panel and the G-ULTRA to change the activation to “GND”.