Frame 9e Gas Turbine Plant2
-
Upload
bruce-kfoo -
Category
Documents
-
view
509 -
download
20
Transcript of Frame 9e Gas Turbine Plant2
For Further Information, please contact GTI: www.GTI-Power.com
Stan Green Larry Rayman
[email protected] [email protected]
Tele: +1-312-371-9999 Tele: +1-561-414-9696
Two GE Frame 9E Power Plants 2 EACH GE FRAME 9E, PG9161, MS9001
Take advantage of our current availability
Financing can be arranged
Priced at a fraction of new
Gas Turbines International, LLC. (GTI) is offering for sale 2 each GE PG9161
Frame 9E Power Packages. 50 HZ, 116.4 MW, each Dual Fuel, Low Hours,
Complete BOP, & Includes 2 Transformers.
GTI’s Power Generation Services: •Complete Power Plant Installations •Supply, Install and Commission •Operation & Maintenance •Specialist Agreement for Gas Turbine and Balance of Plant •Plant Rehabilitation & Relocation •Training •Complete Engineering & Design Capabilities •Financial Strength •OEM Support •Refurbished and Warranted
•Turnkey
Visit us on our website: www.GTI-Power.com
Date of Manufacture- 1992 Total Hours Fired- 15,000 Total Starts- 800
For Further Information, please contact GTI: www.GTI-Power.com
Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696
GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001
Rated Output (Generator Terminals) MW 116.4 per Unit
MS9001 RATINGS NATURAL GAS DISTILLATE BASE PEAK BASE PEAK OUTPUT- MW 116.4 125.7 114.2 123.3 HEAT RATE-Kcal/kWh (LHV) 2608 2598 2631 2621 HEAT RATE- Btu/kWh (LHV) 10350 10310 10440 10400
SCOPE OF SUPPLY Gas Turbine with essential auxiliaries, Gas Turbine Control System Generator, Starter Device and all auxiliary equipment Excitation and excitation control equipment Gas Supply line and valves from gas receiving station Gas Emergency stop valve, governor valve and actuators Gas Vent stack, Distillate supply pipeline and valves for connecting into overland supply Lubricating oil main pump AC driven pump, DC Driven pump, Jacking oil pump Lubricating oil tanks, filters, coolers and purifiers Clean oil tank and pipe work All pipework and valves for lube system Cooling water system including pumps, filters, coolers, fans, pipework and valves Air intake filters, silencer, ductwork and ancillary equipment Exhaust gas ductwork and silencer Exhaust stack, Auxiliary drive gear unit Automatic barring and inching gear Control oil supply including pumps, filters, valves, actuators and pipework Gas Generator protection equipment Plant supervisory and condition monitoring equipment Pressure, temperature, vibration and flow measuring instrumentation Local instruments, gauges, controls and panels Gas Turbine enclosure and ventilation equipment Gas Detectors and display panel Special maintenance tooling Full set of Manuals Plant drawings
For Further Information, please contact GTI: www.GTI-Power.com
Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696
GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001
TECHNICAL PARTICULARS GAS TURBINE GENERAL DATA
Gas Turbine Model PG9161
Power Output (Generator Terminals MW 116.4
Efficiency (Referred to Generator Terminals) % 33
Rotor Speed RPM 3000
Direction of Rotation (looking From Generator) CLOCKWISE
Number of Compressor Stages 17
Temperature at Air Intake °C 15
Atmospheric Pressure bar 1.013
Pressure Drop up to Compressor Inlet mbar 10
Compressor Pressure Ratio 11.6
Compressor Exhaust Temperature °C 343
Compressor Efficiency % PROPRIETARY
Variable Geometry Stages 1
Air Bleed-off Stages 2
Number of Combustion Chambers 14
Dual Fuel System Yes
Fuel Nozzles/ Combustor 1
Ignition System Spark Plug
Combustion Wall Temperature °C PROPRIETARY
Fuel Consumption Kg/S 11.4
Method of NOx Reduction (Alternative Offer) WATER INJECTION
Number of Turbine Stages 3
Date of Manufacture 1992
Total Fired Hours 15,000
Total Starts 800
For Further Information, please contact GTI: www.GTI-Power.com
Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696
GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001
For Further Information, please contact GTI: www.GTI-Power.com
Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696
GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001
For Further Information, please contact GTI: www.GTI-Power.com
Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696
GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001
For Further Information, please contact GTI: www.GTI-Power.com
Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696
GE Frame 9E Gas Turbine Plant
2 EACH GE FRAME 9E, PG9161, MS9001
OUTPUT: KVA 150625 TYPE: BRUSH TURBO-GENERRATOR
R/MIN: 3000 FRAME: BDAX9-450PRH
VOLTS: 14000 MACHINE NO: 37694A-1G
AMPS: 6211 RATING: CONTINUOUS
P.F: 0.800 SPEC: BS 5000 PT II
PHASES/HZ: 3/50 AMBIENT TEMP: 15.0°C
PHASE CONN: STAR ALTITUDE: UP TO 1000 M
EXCITER VOLTS: 180 COOLANT: WATER AT 24°C
EXCITER AMPS: 1540 ROTOR INSULATION: CLASS F
DATE: 1990 STATOR INSULATION: CLASS F
1. Distillate inlet. Sale will include tanks if wanted. 2. Gas termination at fire shut off valve on the upstream side (fuel gas meters are not included). 3. Air inlets are included 4. Gas exhaust includes the chimneys. 5. Electrical termination.
A) 132/14KV Transformer on 132KV bushing. This allows synch on 3GO/4GO with Generator Transformer back energised.
B) Essential Services Boards 1 and 2 remain allowing purchaser to take Essential Services Boards 3 & 4.
C) Station Boards 1 and 2 remain allowing purchaser to take Unit Boards 3 and 4 D) Unit Transformers 3 and 4 are included in the sale.
E) Generator Transformers 3 and 4 are included in the sale
For Further Information, please contact GTI: www.GTI-Power.com
Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696
ESTIMATED PERFORMANCE
GE FRAME 9E GAS TURBINE, PG9161, MS9001
BASE LOAD FUEL: NATURAL GAS ALTITUDE A- SEA LEVEL
MODE: SIMPLE CYCLE B-500m
INLET LOSS: 8.89cm H₂O C-1,000m
EXHAUST LOSS: 12.7cm H₂O D-1,500m
90
80
100
110
120
130
140
A
B
C
D
POWER OUTPUT, MEGAWATTS
50 40 30 20 10 0 -10
AMBIENT TEMPERATURE, deg C.
For Further Information, please contact GTI: www.GTI-Power.com
Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696
ESTIMATED PERFORMANCE
GE FRAME 9E GAS TURBINE, PG9161, MS9001
BASE LOAD FUEL: NATURAL GAS ALTITUDE A- SEA LEVEL
MODE: SIMPLE CYCLE B-500m
INLET LOSS: 8.89cm H₂O C-1,000m
EXHAUST LOSS: 12.7cm H₂O D-1,500m
900
50 40 30 20 10 0 -10
1000
1100
1200
1300
1400
1500
HEAT CONSUMPTION,
KJ/HR X 10⁶(LHV)
AMBIENT TEMPERATURE, deg C.
A
B
C
D
For Further Information, please contact GTI: www.GTI-Power.com
Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696
ESTIMATED PERFORMANCE
GE FRAME 9E GAS TURBINE, PG9161, MS9001
BASE LOAD FUEL: DISTILLATE ALTITUDE A- SEA LEVEL
MODE: SIMPLE CYCLE B-500m
INLET LOSS: 8.89cm H₂O C-1,000m
EXHAUST LOSS: 12.7cm H₂O D-1,500m
80
90
100
110
120
130
140
POWER OUTPUT, MEGAWATTS
A
B
C
D
50 40 30 20 10 0 -10
AMBIENT TEMPERATURE, deg C.
For Further Information, please contact GTI: www.GTI-Power.com
Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696
ESTIMATED PERFORMANCE
GE FRAME 9E GAS TURBINE, PG9161, MS9001
BASE LOAD FUEL: DISTILLATE ALTITUDE A- SEA LEVEL
MODE: SIMPLE CYCLE B-500m
INLET LOSS: 8.89cm H₂O C-1,000m
EXHAUST LOSS: 12.7cm H₂O D-1,500m
9002
2 50 40 30 20 10 0 -10
1000
1100
1200
1300
1400
1500
HEAT CONSUMPTION,
KJ/HR X 10⁶(LHV)
AMBIENT TEMPERATURE, deg C.
A
B
C
D
For Further Information, please contact GTI: www.GTI-Power.com
Stan Green Larry Rayman [email protected] [email protected] Tele: +1-312-371-9999 Tele: +1-561-414-9696
FRAME SIZE: BDAX.9-450 PRH ENCLOSURE: CACW
1. RATING
Output MVA 150.625 at 34°C cooling air
Power Factor 0.8
Voltage kV 14
Frequency Hz 50
Speed rpm 3000
Specification BS5000 Pt.2 & IEC 34.3
2. REACTANCES to a base of 150.625MVA (Calculated)
Synchronous Reactance Xdi 230%
Transient Reactance X'dr 22%
Sub-Translent Reactance X''dr 13.4%
Negative Sequence Reactance X2i 16.25%
3. CURVES Issue
Output/Coolant Temperature H.E.P. 7033 2
Reactive Capability Diagram H.E.P. 7381 1
Open Circuit/Short Circuit H.E.P. 7695 1
Efficiency H.E.P. 4512 5
Negative Sequence Capability H.E.P. 7694 1
4. RECOMMENDED ALARM AND TRIP SETTINGS
Alarm Trip Alarm Trip
Stator Winding Temp °C 150 160 Exciter Air Outlet Temp °C 105 -
Bearing Oil Outlet Temp °C 87 90 Bearing Housing mm/sec *Vibration Peak Velocity inches/sec
Peak to Peak Displacement mm
9 0.35 0.1
19 0.75 0.15 T.P.J. Metal Temp °C 105 110
Generator Air Outlet Temp °C 105 - Shaft Relative Vibration inches X10¯³ 4 6
*If vibration is measured in terms of amplitude:
Zero to peak amplitude (µm)= peak velocity (mm/sec) X 9550
R.P.M.