FlexiPacket MultiRadio Rel. 2.5 FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning A25000-A1600-C040-01-76P1 Issue: 1 Issue date: May 2012 Nokia Siemens Networks is continually striving to reduce the adverse environmental effects of its products and services. We would like to encourage you as our customers and users to join us in working towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations for power use and proper disposal of our products and their components. If you should have questions regarding our Environmental Policy or any of the environmental services we offer, please contact us at Nokia Siemens Networks for any additional information.

description

fpmr

Transcript of FPMR 2.5 and IDU Commissioning

  • FlexiPacket MultiRadioRel. 2.5

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    A25000-A1600-C040-01-76P1

    Issue: 1 Issue date: May 2012

    Nokia Siemens Networks is continually striving to reduce the adverse environmental effects of its products and services. We would like to encourage you as our customers and users to join us in working towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations for power use and proper disposal of our products and their components.

    If you should have questions regarding our Environmental Policy or any of the environmental services we offer, please contact us at Nokia Siemens Networks for any additional information.

  • 2 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.

    The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.

    Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMEN-TATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.

    This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.

    The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

    Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.

    Copyright Nokia Siemens Networks 2012. All rights reserved.

    f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources of danger.

    Only trained and qualified personnel may install, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product.

    The safety information is provided in the Safety Information section in the Legal, Safety and Environmental Information part of this document or documentation set.

    The same text in German:

    f Wichtiger Hinweis zur Produktsicherheit Von diesem Produkt knnen Gefahren durch Laser, Elektrizitt, Hitzeentwicklung oder andere Gefahrenquellen ausgehen.

    Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-anforderungen erfolgen.

    Die Sicherheitsanforderungen finden Sie unter Sicherheitshinweise im Teil Legal, Safety and Environmental Information dieses Dokuments oder dieses Dokumentations-satzes.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    3

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    Table of ContentsThis document has 61 pages.

    1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.1 Intended audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.2 Structure of this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.3 Symbols and conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.4 History of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91.5 Waste electrical and electronic equipment (WEEE) . . . . . . . . . . . . . . . . 91.6 RoHS compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.7 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.7.1 RF Energy Health Hazard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101.7.2 Protection against Lightning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111.7.3 Protection from RF Burns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111.7.4 Warning Turn off all power before servicing . . . . . . . . . . . . . . . . . . . . 11

    2 FlexiPacket Microwave scenarios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122.2 Procedure overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.3 PC requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.4 Commissioning procedures for the System Types already available with

    FlexiPacket MultiRadio SVR 2.4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132.5 Commissioning procedure for 2+2 XPIC . . . . . . . . . . . . . . . . . . . . . . . . 142.5.1 IDU configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162.5.2 IDU-ODU configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402.5.3 Example: E-LAN for Ethernet traffic with VID 1000 . . . . . . . . . . . . . . . . 502.6 Commissioning procedure for 2+0 XPIC Ring . . . . . . . . . . . . . . . . . . . . 562.6.1 How to configure the Ring Head NE . . . . . . . . . . . . . . . . . . . . . . . . . . . 572.6.2 How to configure the Ring Node NE . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

    3 Acronyms and abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

  • 4 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    List of FiguresFigure 1 WEEE label. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Figure 2 Station block diagram (Example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Figure 3 Single IDU solution (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Figure 4 Two IDUs solution (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57Figure 5 Acting Master (Radio) Sync Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Figure 6 Acting Slave (Radio) Sync Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Figure 7 Acting Master (GbE) Sync Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Figure 8 Acting Slave (GbE) Sync Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    5

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    List of TablesTable 1 Structure of this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Table 2 List of symbols and conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Table 3 History of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Table 4 Supported IDUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Table 5 System Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

  • 6 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    7

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    Preface

    1 PrefaceThis document provides a guideline for placing into service a FlexiPacket MultiRadio link.

    1.1 Intended audienceThis document is intended to the commissioning technicians in charge to commission a FlexiPacket MultiRadio link (IDU+ODU).

    1.2 Structure of this documentThe document is divided into the following main chapters:

    1.3 Symbols and conventionsThe following symbols and mark-up conventions are used in this document:

    Chapter Title Subject

    Chapter 1 Preface Provides an introduction to the document and the safety instructions

    Chapter 2 FlexiPacket Microwave sce-narios

    Provides the procedure to line-up and commission the FlexiPacket MultiRadio connected to a Nokia Siemens Networks Hub

    Chapter 3 Acronyms and abbreviations Lists the acronyms and abbreviations used in this document

    Table 1 Structure of this document

    Representation Meaning

    fDANGER!fWARNING!fCAUTION!

    A safety message indicates a dangerous situation where personal injury is possible.

    The keywords denote hazard levels with the following meaning:

    DANGER! - Indicates a hazardous situation which, if not avoided, will result in death or serious (irreversible) personal injury.

    WARNING! - Indicates a hazardous situation which, if not avoided, could result in death or serious (irreversible) personal injury.

    CAUTION! - Indicates a hazardous situation which, if not avoided, may result in minor or moderate (reversible) personal injury.

    w NOTICE: A property damage message indicates a hazard that may result in equipment damage, data loss, traffic interruption, and so on.

    Table 2 List of symbols and conventions

  • 8 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    Preface

    g A note provides important information related to the topic, for example, not obvious exceptions to a rule or side effects.

    t A tip provides additional information related to the topic which is not essential in the context, but given for convenience.

    Bold All names of graphical user interface (GUI) objects, such as windows, field names, buttons, and so on.Example: Select the Full Screen check box and press OK.

    Terms and abbreviations which are linked to an entry in the glossary and list of abbreviations respectively.

    Important key words.

    Italic Files, folders, and file system paths.Example: /usr/etc/sbin/ftpd.exe

    Emphasized words.

    typewriter Input to be typed in a command line or a GUI field.Examples:ping -t 192.168.0.1Enter World in the Domain field.

    Output from a command, error messages, content of a status line, and so on.

    File content, such as program sources, scripts, logs, and set-tings.

    Placeholders, for example as part of a file name or field value.

    Examples:.png or :

    [square brackets] A key to be pressed on a PC keyboard, for example [F11].

    Keys to be pressed simultaneously are concatenated with a + sign, for example [CTRL]+[ALT]+[DEL].

    Keys to be pressed one after another are concatenated with spaces, for example [ESC] [SPACE] [M].

    > The greater than symbol > is used to concatenate a series of GUI items in order to depict a GUI path. This is an abridged pre-sentation of a procedure to be carried out in order to perform an action or display a window or dialog box.

    Examples:

    A simple menu path: File > Save as ...A more complex GUI path:> Nokia Siemens Networks TransNet window > File menu > Change Password command > Change Password dialog box

    Representation Meaning

    Table 2 List of symbols and conventions (Cont.)

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    9

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    Preface

    Screenshots of the graphical user interface are examples only to illustrate principles. This especially applies to a software version number visible in a screenshot.

    1.4 History of changes

    1.5 Waste electrical and electronic equipment (WEEE)All waste electrical and electronic products must be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. The WEEE label (see Figure 1) is applied to all such devices.

    Figure 1 WEEE label

    The correct disposal and separate collection of waste equipment will help prevent poten-tial negative consequences for the environment and human health. It is a precondition for reuse and recycling of used electrical and electronic equipment.

    For more detailed information about disposal of such equipment, please contact Nokia Siemens Networks.

    The above statements are fully valid only for equipment installed in the countries of the European Union and is covered by the directive 2002/96/EC. Countries outside the European Union may have other regulations regarding the disposal of electrical and electronic equipment.

    x(in card names)

    For convenience, card names are sometimes listed with a lower case x variable, in order to concisely represent multiple cards.

    Example:

    I01T40G-x (is to be interpreted as I01T40G-1 and I01T40G-2)

    Representation Meaning

    Table 2 List of symbols and conventions (Cont.)

    Issue Issue date Remarks

    1 May 2012 1st version

    Table 3 History of changes

  • 10 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    Preface

    1.6 RoHS complianceFlexiPacket MultiRadio complies with the European Union RoHS Directive 2002/95/EC on the restriction of use of certain hazardous substances in electrical and electronic equipment.

    The directive applies to the use of lead, mercury, cadmium, hexavalent chromium, poly-brominated biphenyls (PBB), and polybrominated diphenylethers (PBDE) in electrical and electronic equipment put on the market after 1 July 2006.

    Materials usage information on Nokia Siemens Networks Electronic Information Products imported or sold in the Peoples Republic of ChinaFlexiPacket MultiRadio complies with the Chinese standard SJ/T 11364-2006 on the restriction of the use of certain hazardous substances in electrical and electronic equip-ment. The standard applies to the use of lead, mercury, cadmium, hexavalent chro-mium, polybrominated biphenyls (PBB), and polybrominated diphenyl ethers (PBDE) in electrical and electronic equipment put on the market after 1 March 2007.

    1.7 Safety instructionsIn this paragraph are indicated all the safety rules and the precautionary measures to follow while carrying out operations on the equipment in order to prevent injuries to per-sonnel and/or damages to the equipment components.

    t PLEASE READ THESE SAFETY PRECAUTIONS!

    1.7.1 RF Energy Health Hazard

    This symbol indicates a risk of personal injury due to radio frequency exposure.

    The radio equipment described in this guide uses radio frequency transmitters.

    No one shall be allowed to come in the close proximity of the antenna's front while the transmitter is operating. The antenna will be professionally installed on the outdoor per-manent fix-mounted structures in order to keep it separate from any other antenna and from everybody else.

    f WARNING!RF Energy Exposure Limits and Applicable Rules for 6-38 GHz. It is recommended that for each radio equipment deployment site the radio equipment operator refers to the RF exposure rules and precaution for each frequency band and to all other applicable rules and precautions with respect to transmitters, facilities, and operations that may affect the environment due to the RF emissions.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    11

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    Preface

    Appropriate warning signs must be properly placed and affixed at the equipment site and access entries.

    1.7.2 Protection against Lightning

    Article 810 of the US National Electric Department of Energy Handbook 1996 specifies that radio and television lead-in cables must have adequate surge protection at or near the point of entry to the building. The code specifies that any shielded cable from an external antenna must have the shield directly connected to a 10 AWG wire that connects to the building ground electrode.

    Do not turn on power before reading product documentation. This device has a -48 VDC direct current input.

    1.7.3 Protection from RF BurnsIt is dangerous to stare into or stand in front of an active antenna aperture. Do not stand in front of or look into an antenna without first ensuring that the associated transmitter or transmitters are switched off. Do not stare into the waveguide port of an ODU (if appli-cable) when the radio is active.

    1.7.4 Warning Turn off all power before servicing

    f WARNING!Turn off all power before servicing.

  • 12 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    2 FlexiPacket Microwave scenarios

    2.1 OverviewThis document describes the sequence of steps to be adopted in order to install a site with Hub+FPMR(P) SVR 2.5 Network Elements.

    The supported Hubs are listed in Table 4 and are already supported by the Commission-ing Tool CT1.3SU2.

    In case of the usage of NON-NSN IDUs, the ODUs must be configured connecting directly the management PC, either via CT or (in this case better) with the WebLCT just to avoid to use two different tools. In these scenarios the powering of the ODUs should be already in place without the P+E support.

    With the FPMR(P) SVR 2.5 the System Types in Table 5 are available:

    Supported IDUs Abbreviations

    FlexiPacket Hub A1200 R5.0 (drop1, 2, 3) A1200 or FPH1200

    FlexiPacket Hub A2200 R4.5, R4.5 EP1,R5.0 A2200 or FPH2200

    FlexiPacket FirstMile 200 R1.0 EP1 FirstMile 200 or FPFM200

    FlexiPacket FirstMile 200 R2.0 FirstMile 200 or FPFM200

    FlexiPacket Hub 800 R2.0 Hub 800 or FPH800

    Table 4 Supported IDUs

    No. System Type Available in SVR

    1 1+0/1+0 Ring 2.4

    2 1+1 Hot Stand-by - two cables 2.4

    3 1+1 Hot Stand-by - single cable 2.4

    4 1+1 FD - two cables 2.4

    5 1+1 SD - two cables 2.4

    6 2+0 FD - two cables 2.4

    7 2+0 XPIC - two cables 2.4

    8 2+0 XPIC - single cable 2.4

    9 2+2 XPIC - two cables 2.5

    10 2+0 XPIC Ring - two cables 2.5

    Table 5 System Types

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    13

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    2.2 Procedure overviewHere below are listed the main steps to configure for the first time a link made up of FlexiPacket MultiRadio and Nokia Siemens Networks Hub.

    Steps

    1 Build the site as in the final set-up (Hub+ODUs and related cabling). The NE should be powered as in the final set-up (P+E, Power Injector or Direct Power).

    2 Connect the CT PC to the reserved DCN Port of the Hub.

    3 If the system type to be configured is:

    a system type already available with the SVR 2.4 (from 1 to 8 in Table 5) follow the procedure in paragraph 2.4 on page 13;

    a 2+2 XPIC system type (available only in SVR 2.5) follow the procedure in para-graph 2.5 on page 14;

    a 2+0 XPIC Ring system type (available only in SVR 2.5) follow the procedure in paragraph 2.6 on page 56.

    t The ODU software can be 2.5 or 2.4 or 2.1 (in the last two cases the ODU can be upgraded also in field).

    2.3 PC requirementsRefer to paragraph 2.2 of FlexiPacket Commissioning Tool, Rel. 1.3SU2, Operating Documentation, Issue 1 - A25000-A1400-D000-01-76P1.

    2.4 Commissioning procedures for the System Types already available with FlexiPacket MultiRadio SVR 2.4Steps

    1 Follow the procedure explained in document FlexiPacket Commissioning Tool, Rel. 1.3SU2, Operating Documentation, Issue 1 - A25000-A1400-D000-01-76P1.

    2 At the end of the operations in Step 1 open the ODU WebLCT and upgrade the ODU SW from SVR 2.4 to SVR 2.5.

  • 14 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    2.5 Commissioning procedure for 2+2 XPICThis paragraph gives the procedures to install for the first time (starting from scratch) the FlexiPacket Hub 800 and the FlexiPacket MultiRadio to commission the radio link.

    The initial ODU SVR is 2.1.

    The Commissioning Tool configures the ODUs with svr 2.4 and system type 2+0 XPIC.

    Figure 2 shows an example of the configuration with all the parameters to be configured.

    Figure 2 Station block diagram (Example)

    Follow the steps here below and the steps in paragraphs 2.5.1 on page 16 and 2.5.2 on page 40.

    Steps

    1 Connect the Ethernet cable from your computer Ethernet port to the OBB connector of the FlexiPacket Hub 800.

    OOB IP address is 192.168.254.100

    2 Upgrade the FlexiPacket Hub 800 to R 2.0.

    3 Connect the Ethernet cable from your computer Ethernet port to the DCN connector of the FlexiPacket Hub 800 (DCN default IP address: 192.168.255.100).

    4 Run the FlexiPacket Commissioning Tool application from Start > Programs > Nokia Siemens Networks > Commissioning Tool > Run CT.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    15

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    5 Select FPH800.

  • 16 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    2.5.1 IDU configuration

    Steps

    1 Click Next.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    17

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    2 Click Next (Add Row if you have License key).

    3 Configure and click Next.

  • 18 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    4 Configure and click Add.ODU type must be 2xFPMR(P).Power supply must be Enable.PWR source must be PWR on integrate device.

    5 Configure and click Add.ODU type must be 2xFPMR(P).Power supply must be Enable.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    19

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    PWR source must be PWR on integrate device.

    6 Check and click Next.

  • 20 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    7 Add if you want another Management Port and click Next.

    8 Configure and click Add.ODU type must be 2xFPMR(P).ODU system type must be 2+0 XPIC 1 Cable.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    21

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    9 Configure and click Add.ODU type must be 2xFPMR(P).ODU system type must be 2+0 XPIC 1 Cable.

    10 Check and click Next.

  • 22 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    11 Browse and select FPMR 2.4 software file for both row to upgrade from SVR 2.1 to SVR 2.4.

    12 Click Modify.

    13 Fill Licence key and click Add.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    23

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    14 Fill Licence key and click Add.

    15 Click Next.

  • 24 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    16 Configure and click Modify.

    17 Configure and click Modify.

    18 Click Next.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    25

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    19 Configure and click Modify.

    20 Configure and click Modify.

    21 Click Next.

    22 Configure and click Modify.

  • 26 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    23 Set Source SyncE transfer: NCT (if no clock transfer).

    24 Configure and click Modify.Set Source SyncE transfer: NCT (if no clock transfer).

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    27

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    t Set Source SyncE setting Radio for remote 4 ODUs, if Source SyncE transfer Fixed and Source SyncE setting Ethernet in the local ODU.

    25 Modify if necessary and click Next.

    26 Configure and click Modify.

  • 28 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    Radio port service status must be down.

    27 Configure and click Modify.Radio port service status must be down.Click Next.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    29

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    28 Modify if necessary and click Next.

    29 Click on Save As.

    30 Click Next.

  • 30 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    31 Select Use default IP.

    32 Click Next.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    31

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    33 Click Yes.

  • 32 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    34 Click OK.

    35 Click Yes.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    33

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    36 Click Validate.

  • 34 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    37 Write the IP address.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    35

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    38 Click Next.

  • 36 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    39 Click Run.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    37

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

  • 38 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    39

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    40 Click Next.

    41 Check and click Next.

    42 Click Exit.

  • 40 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    2.5.2 IDU-ODU configuration

    Steps

    1 On the FlexiPacket Hub 800 disable E-CCM.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    41

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    2 Open the ODU WebLCT and upgrade the ODU from SVR 2.4 to SVR 2.5 (starting from co-located).

    3 Switch the sw version.

    4 Close and restart the ODU WebLCT and web browser.

    5 Open again the ODU WebLCT.

    6 Change the system type to 2+2 XPIC.

  • 42 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    7 Set P-CCM.

    8 Align the SVR loads.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    43

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    9 Open the IDU WebLCT and create IDU E-LINE for P-CCM.

  • 44 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    10 Configure and click Next.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    45

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    11 VLAN ID is P-CCM of ODU.

  • 46 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    47

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    12 With the ODU WebLCT set for each ODU of the 4 ODU group:

    ODU role ODU radio Priority Switch modeaccording to the ODU parameters shown in Figure 2 on page 14 (only as example).

  • 48 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    49

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    13 After the setting of the 4 ODUs, set the service state to Up.

    14 With the IDU WebLCT set the IDU synchronization in Menu Clock Sych > Create.

    15 The procedure is complete.

  • 50 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    2.5.3 Example: E-LAN for Ethernet traffic with VID 1000

    Steps

    1 Set the Admin Status to UP and the mode to UNI for the port GE 0/1.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    51

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

  • 52 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    2 Set VLAN ID to 1000.

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    53

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

  • 54 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    55

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

  • 56 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    2.6 Commissioning procedure for 2+0 XPIC RingThe 2+0 XPIC Ring System Type can be implemented only with FirstMile and Flexi-Packet Hub800.

    Two IDU solutions can be adopted:

    with Single IDU: only 1 IDU in the Station (refer to Figure 3) with Two IDUs: 2 IDUs in the Station (refer to Figure 4)

    Figure 3 Single IDU solution (example)

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    57

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    Figure 4 Two IDUs solution (example)

    In the Two IDUs Solution the 2 IDUs must be of the same type.

    In the figures the arrow shows the synch direction (clockwise).

    In the Ring Head NE the configured system type must be 2+0 XPIC, in all the other NEs (Ring Node) the configured system type must be 2+0 XPIC Ring.

    2.6.1 How to configure the Ring Head NE

    Steps

    1 Follow the procedure explained in document FlexiPacket Commissioning Tool, Rel. 1.3SU2, Operating Documentation, Issue 1 - A25000-A1400-D000-01-76P1 and select the System Type 2+0 XPIC.

    2 At the end of the operations in Step 1 open the ODU WebLCT and upgrade the ODU SW from SVR 2.4 to SVR 2.5.

    3 The procedure is complete.

    2.6.2 How to configure the Ring Node NE

    Steps

    1 Follow the procedure explained in document FlexiPacket Commissioning Tool, Rel. 1.3SU2, Operating Documentation, Issue 1 - A25000-A1400-D000-01-76P1 and select the System Type 2+0 XPIC.

    2 At the end of the operations in Step 1 open the ODU WebLCT and upgrade the ODU SW from SVR 2.4 to SVR 2.5.

    3 With the ODU WebLCT change the System Type to 2+0 XPIC Ring.

  • 58 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    4 With the ODU WebLCT configure the Synchronization according to the information shown (as example) in Figure 3 and Figure 4.

    Four different configurations must be configured:

    Acting Master (Radio) (refer to Figure 5) Acting Slave (Radio) (refer to Figure 6) Acting Master (GbE) (refer to Figure 7) Acting Slave (GbE) (refer to Figure 8)

    Figure 5 Acting Master (Radio) Sync Settings

    Figure 6 Acting Slave (Radio) Sync Settings

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    59

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    FlexiPacket Microwave scenarios

    Figure 7 Acting Master (GbE) Sync Settings

    Figure 8 Acting Slave (GbE) Sync Settings

    5 The procedure is complete.

  • 60 A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200,FPFM200 and FPH800) commissioning

    Acronyms and abbreviations

    3 Acronyms and abbreviationsBER Bit Error Rate

    BFD Bidirectional Forwarding Detection

    BGP Border gateway Protocol

    BSC Base Station Controller

    BTS Base Transceiver Station

    BW Channel Bandwidth

    COS Class of Service

    DSCP Differentiated Services Code Point

    ECC Embedded Communication Channel

    ESW Element SW

    EVC Ethernet Virtual Container

    FPR FlexiPacket Radio

    HSPA High Speed Packet Access

    IGP Interior Gateway Protocol

    IMIX Internet Mix Traffic

    IP VPN Virtual Private IP network

    IS-IS Dynamic routing protocol inside autonomous system

    LCT Local Craft Terminal

    LDP Label Distribution Protocol

    LPG Link Protection Group

    LTE Long Term Evolution

    MGW Media Gateway

    MWR Microwave Radio

    MPLS Multi Protocol Label Switching

    Node B WCDMA BTS (e.g. Flexi/Ultrasite WCDMA BTS)

    OSPF Open Shortest Path First routing protocol

    PCP Priority Code Point (p-bit)

    PHB Per Hop Behavior

    PSN Packet Switched Network

    PW Pseudo-wire

  • A25000-A1600-C040-01-76P1Issue: 1 Issue date: May 2012

    61

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioning

    Acronyms and abbreviations

    QAM Quadrature Amplitude Modulation

    RNC Radio Network Controller

    SAToP Structure Agnostic Service over PSN

    SSM Synchronization Status Message

    TDM Time Division Multiplexing

    TOP Timing Over Packet

    VCCV Virtual Connection Connectivity Verification

    VRF Virtual Routing and Forwarding

    FlexiPacket MultiRadio Rel. 2.5 and IDU (Ax200, FPFM200 and FPH800) commissioningTable of ContentsList of FiguresList of Tables1Preface1.1Intended audience1.2Structure of this document1.3Symbols and conventions1.4History of changes1.5Waste electrical and electronic equipment (WEEE)1.6RoHS compliance1.7Safety instructions1.7.1RF Energy Health Hazard1.7.2Protection against Lightning1.7.3Protection from RF Burns1.7.4Warning Turn off all power before servicing2FlexiPacket Microwave scenarios2.1Overview2.2Procedure overview2.3PC requirements2.4Commissioning procedures for the System Types already available with FlexiPacket MultiRadio SVR 2.42.5Commissioning procedure for 2+2 XPIC2.5.1IDU configuration2.5.2IDU-ODU configuration2.5.3Example: E-LAN for Ethernet traffic with VID 10002.6Commissioning procedure for 2+0 XPIC Ring2.6.1How to configure the Ring Head NE2.6.2How to configure the Ring Node NEAcronyms and abbreviations