FPMR 2+0 XPIC Configuration.pptx

download FPMR 2+0 XPIC Configuration.pptx

of 22

Transcript of FPMR 2+0 XPIC Configuration.pptx

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    1/22

    FPMR 2 0 XPIC Configuration

    Revision 1

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    2/22

    2+0 XPIC Configuration Tool

    WebLCT

    Need do configuration in IDU and ODU WebLCT. All the release

    load support it.

    Flexipacket Wizard 1.4

    Use it to do the basic link setup. Support assisted mode andadvanced mode. Need to check the support software

    combination. It doesnt support all releases.

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    3/22

    IDU and ODU WebLCT

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    4/22

    2+0 XPIC Major Configuration

    IDU configuration

    1. Create LPG

    2. Add Management E-lan

    3. Enable E-ccm

    ODU configuration

    4. Frequency and Bandwidth setting

    5. System mode setting

    6. Protection role setting

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    5/22

    1. LPG established between 2 NNI ports

    P-CCM VID should be same as it in ODUs.

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    6/22

    2. Add LPG ports to the management E-Lan

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    7/22

    3. ECCM should be enabled on the LPG member

    ports

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    8/22

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    9/22

    2. Configure the 2 ODUs on the one side for the 2+0XPIC mode

    The PCCM vlan should be same as IDU. The 2 ODU should be in the

    different Polarity

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    10/22

    3. The ODU1A ODU role should be master. TheODU1B ODU role should be slave.

    It should be same PCCM and A-CCM interval configuration between the

    ODU master and ODU slave

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    11/22

    Flexipacket Wizard 1.4

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    12/22

    Flexipacket Wizard 1.4

    FPWizard 1.4 support Assisted

    mode and Advanced mode.

    Please check the support

    combination before using it.

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    13/22

    Assisted mode

    In assisted mode, just finish the configuration step by step according to

    the process.

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    14/22

    Advanced mode

    1. Set IDU basic parameter, configure the IDU IP, management VID.

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    15/22

    Advanced mode

    2. Add ODU devices, configure ODU IP and power source

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    16/22

    Advanced mode

    3. Adding ODU device finished, you can find the connected ODUs

    information

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    17/22

    Advanced mode

    4. Configure ODU system type to 2+0 XPIC

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    18/22

    Advanced mode

    5. Add LPG and configure ODU protection role.

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    19/22

    Advanced mode

    6. Configure ODUs basic parameters.

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    20/22

    Advanced mode

    *Need to apply the modification in each page.

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    21/22

    Advanced mode

    *Need to apply the modification in each page.

  • 8/10/2019 FPMR 2+0 XPIC Configuration.pptx

    22/22

    Advanced mode

    *Need to apply the modification in each page.