for Green Living R410A · 2018. 6. 27. · International Aircon Pvt. Ltd. with its nationwide...
Transcript of for Green Living R410A · 2018. 6. 27. · International Aircon Pvt. Ltd. with its nationwide...
-
HYBRIDAIRCONDITIONER
+HYPERINVERTER
R410AECO-FRIENDLY
for Green
Living
for Green
Living
-
IndexIndex
1
2 FUTURE & TECHNOLOGY FOR AIR CONDITIONER
3 4 MHI GLOBAL ACTIVITY
5 6 MITSUBISHI HEAVY INDUSTRIES, LTD. OVER VIEWHYBRID AC FEATURE LIST
7 8 JET FLOW & 3D AIR FLOW TECHNOLOGY
9 10 CLEAN AIR FUNCTION & FILTERATION
11 14 CUSTOMER FRIENDLY FUNCTION OVER VIEW
15 16 ECO SMART HYBRID RANGE
17 20 ECO SMART HEAVY DUTY RANGE
21 22 ECO SMART HYPER INVERTER COOLING ONLY
BACK IAPL BRANCHES ( SALES & SERVICE)
~
~
~
~
~
~
~
~
+
+
2 FUTURE & TECHNOLOGY FOR AIR CONDITIONER
3 ~ 4 MHI GLOBAL ACTIVITY
5 ~ 6 MITSUBISHI HEAVY INDUSTRIES, LTD. OVER VIEW+
HYBRID AC FEATURE LIST
7 ~ 8 JET FLOW & 3D AIR FLOW TECHNOLOGY
9 ~ 10 CLEAN AIR FUNCTION & FILTERATION
11 ~ 14 CUSTOMER FRIENDLY FUNCTION OVER VIEW
+15 ~ 16 ECO SMART HYBRID RANGE
17 ~ 20 ECO SMART HEAVY DUTY RANGE
21 ~ 22 ECO SMART HYPER INVERTER COOLING ONLY
BACK IAPL BRANCHES ( SALES & SERVICE)
PAGESPAGES DESCRIPTIONDESCRIPTION
-
Established Since - 1884
Future and technology for air conditioning
For a better tomorrow
Research and technological innovation have been the goals of Mitsubishi Heavy Industries for over a century and these have been translated into the excellent results in the air conditioning products.
The perfect harmony between energy, technology and innovation is manifested in the production of air conditioners designed to meet the engineering needs of the residential, commercial and industrial sectors. State of the art solutions applied to top quality to guarantee wellbeing, energy saving and quality life.
Harmonizing People and technology on a global scaleAs a global manufacturer, the fields in which Mitsubishi Heavy Industries work, know no limits, offering more than 700 products that fall in all sectors and meet different needs and lifestyles, with the aim of reconciling public needs and technological innovation.With its eyes on the future, MHI will continue to traverse uncharted lands.
2
-
Established Since - 1884
-
The origin of MHI can be all the way back to 1884. In that year, Yataro Iwasaki, the founder of Mitsubishi took a lease of Government- owned Nagasaki Shipyard. He named it Nagasaki Shipyard & Machinery Works, and started the shipbuilding business on a full scale. This shipbuilding business was later turned into Mitsubishi Shipbuilding Co.,Ltd., and was again launched as Mitsubishi Heavy- Industries, Ltd., in 1934, establishing its position as the largest private firm in Japan. Mitsubishi Heavy Industries is Japan's largest shipbuilding and machinery maker and is a mammoth company involved in an array of Industrial concerns. With nearly 150 subsidiaries, Mitsubishi Heavy Industries Ltd. (MHI) operates in 11 key sectors. Shipbuilding, Air- Conditioning and Refrigeration Systems, Nuclear Energy Systems, General Machinery and Components, Paper and Printing Machinery, Steel Structures and Construction, Machinery and Plants, Machine Tools, Power Systems, Aerospace System, Industrial Machinery, Infrastructure projects and produces everything from Airconditioners & System (Room AC, Semi- Commercial, Commercial, VRF, Centrifugal & Absorption Chillers), Jet engines, Passenger aircraft, Wind- Mills, Cruise ships and Oil tankers, to Construction Machinery, Newsprint Machines, Turbines, Nuclear Power Plants, Thermal Power Plants airplanes, gasoline engines, and gear cutting machines.
Mitsubishi Heavy Industries Japan133 years of technological innovations
Yataro Iwasaki, founder of Mitsubishi
1884: the Nagasaki shipyards at the timethe company was founded
Mitsubishi Heavy Industries- International Aircon Pvt. Ltd. is a Strategic alliance of Mitsubishi Heavy Industries - Mahajak Airconditioners Co. Ltd. & International Aircon Pvt. Ltd., for sales, marketing & service of Mitsubishi Heavy Ind. Heavy Duty Room, Commercial Airconditioners & VRF Systems in India.
International Aircon Pvt. Ltd. with its nationwide network has supported a wide array of projects inc lud ing res ident ia l & la rge commerc ia l establishment, Offices, Business establishments, Hotels, Hospitals, Schools, Commercial Complexes, Industries, etc. We have participated in projects for large Air Conditioning Systems requiring SYSTEM INTEGRATION of imported air conditioning equipment as per the international standards lay down by our principal- M/s. Mitsubishi Heavy Industries Ltd. We ensure much superior quality of workmanship with advanced engineering skills. We have full- fl edged team of qualified engineers and technical staff in the air- conditioning divisions to meet all kind of requirements. IAPL has consistently provided Channel Partners with timely and high value service, competitively priced products without sacrificing quality.
IAPL has its branch offices in all the major cities of India Including Delhi, Mumbai, Kolkatta, Benguluru, Chennai, Kochi, Ahmedabad, Hyderabad, Jaipur, Chandigarh, Gurgaon, Karnal, Ludhiana, Lucknow, Noida, Nagpur, Indore, Patna, Bhubaneswar, Jammu & Dehradun. Company has Authorized Genuine Spares & Service Center Network at all major cities of India.
-
R410AECO-FRIENDLY
POWER FULL
COOLING
-
59 feet *59 feet *59 feet *59 feet *59 feet *50 feet *50 feet *50 feet *50 feet *50 feet * 60 feet *60 feet *60 feet *60 feet *60 feet *
JET FLOW POWERFUL
& SILENT AIR FLOW
You can set the left-right air flow directions when youinstall the air conditioner near the side wall by remotecontroller operation.
POSITIONING OF INSTALLATIONDue to redesigned size and shape, the new louver hasbeen increased in surface area by 80%. In addition toincrease of air flow volume, it has improved controllability of swinging to right and left.
NEW LOUVER
80% INCREASED
JET ENGINE TECHNOLOGYCFD (computational fluid dynamics), used in bladeshape design of jet engines, has been applied to thedesign of air channels in air conditioners to develop theideal air channel system (air circulation). The air flow ofthe jets created in this system enable a large volume ofair to be blown with minimum power consumption, yetthe air flow is uniform, quiet and reaches points a longdistance from the blower.
Increase Your Comfort
LONG REACHAIR FLOW
7
Powerful air flow is realized by Jet technology. Good for large living rooms and shops. Increase your comfort.
LONG REACH AIR FLOW
-
3D AIR VERTICAL + HORIZONTAL AIR SCROLL
3 MOTORS MAKE 3 INDEPENDENT CONTROLS
3D AIR FLOW
AUTO SETTING (3D AUTO)Hi-Power (Quick)
Wide Swing (Every Corner)
Center (Long)
Wide-Air (Equal)
3D AIR
3D AUTO
3D AUTO is one touch programmed and threemotors (one vertical working motor + two horizontalworking motors) make three independent air flowcontrols. The air flow is uniform and quiet and reachesat long distance points from the blower.
By individual control of right and left part of louver, airflow direction from the right part and the left part arecontrolled individually. Setting the most preferable air flow direction and determining whether direct air flow isrequired or not at the same time minimizing of energyloss and economical operation has realized.
MANUAL SETTING
Thanks to automatic control of air flow volume and airflow direction, comfortable air conditioning of the entireroom can be done effectively.
In cooling operation cooled air flows directly to theceiling. The cooled air does not flow directly to theoccupants of the room and the comfort cooled air flowcomes from the ceiling like a soft shower.
In heating operation warm air flows to the floor directlyand spreads along the floor. Due to concentration of thewarm air on the floor level, optimum comfort can be achieved.
8
-
CLEAN AIR
GENERATES THE SAME AMOUNT OF NEGATIVE IONS AS A FOREST ENVIRONMENT
24-Hour ION
ALWAYS KEEPING THE INDOOR UNIT CLEANSelf Clean Operation
The air conditioner main body employs a tourmaline- coated sheet. The sheet generates negative ions around the clock. Even when the air conditioner is not running, it generates as many negative ions(2,500- 3,000/cc) as in a forest, stream or fall does, allowing you to experience them without incurring anyelectrical charges.
“Self Clean Operation” is operated for 2 hours after the unit has stopped its normal operation. The indoorunit is dried up and the growth of mold is restrained. Users can select whether this mode is utilized or not.
ANTI-MICROBIAL SPECIFICATIONS AND DESIGN WILL DELIVER CLEANLINESS AND SAFETY
ANTI-MICROBIAL BLOWER FAN
9
The blower fan has undergone anti-microbial treatment to resistmold and germs, making the system clean and safe. Foul odorsand molds, etc. which can occur when an air conditioning systemis not in operation are prevented.
SELF CLEANOPERATION
ANTI MICROANTI MICROBIAL FANBIAL FAN
-
Rate of inactivation
against allergens
collected on the filter
The allergen clear filter breaks down the pollen, lice, and allergens that live on cat skins, etc. and deactivates them. The secret of deacti-vation is the Enzyme-Urea compound. It deactivates not only allergens but also all kinds of bacteria, molds and viruses. Even if allergens and bacteria, etc. fly off of the filter, they are deactivated, so the air in your room is kept fresh.
Natural Solar Filter
THE DEODORIZING ABILITY OF THIS FILTER CAN BE EASILY RESTORED SIMPLY BY CLEANING AND EXPOSING TO THE SUNLIGHT
THIS IS THE ORIGINAL AND ONLY
TECHNOLOGY TO CONTROL THE TEMPERATURE
AND HUMIDITY FOR INACTIVATING ALLERGENS
Allergen Clear Filter
THE AIR IN YOUR ROOM IS KEPT FRESH
Allergen Clear System
“Allergen Clear System” is equipped to suppress the influence of the allergen caught by the filter by controlling the temperature and humidity.
Enzymes used in these filters are naturally occurring lytic enzymes. The lytic enzymesattack cell walls of microorganisms trapped on a filter and destroy them and doing so,have a powerful sterilizing which will effectively decrease the number of molds andbacteria. Natural Enzyme Filter will clean and sanitize air passing through it to keep airin the room clean and safe.
SURE TO DESTROY FUNGI AND BACTERIA, ALSO EFFECTIVE ON VIRUSES AND ALLERGENIC COMPOUNDS (CAT HAIR, DUST MITE, POLLEN ETC.)
Natural Enzyme Filter
It will keep the air fresh by deodorizing themolecules causing odor. Its deodorizing powercan be restored by washing with water anddrying under the sun, as such it is capable ofrepeat use.
10
SOLARFILTER
ENZYME
FILTER
FILTER
ALLERGENALLERGEN
-
INTELLIGENT AIRFLOW CONTROLS
HYBRID AC FOR ELECTRICITY SAVING UPTO 47%*
HIGH CAPACITY MACHINES
JET AIR FLOWAircraft technology was used in the design of the air conditioner’s airflow systemWe used the same aerodynamic analysis technology as used in developing jet engines.
CFD (computational fluid dynamics), used in designing of the blades of jet engines has been applied to the design of the louver blades of the centrifugal blower and air delivery path, to develop the ideal air channel system to deliver higher airflow at a lesser noise level.
LONG REACH AIR FLOW
UP/ DOWN SWING:
LATERAL SWING:
The UP/DOWN flap can be adjusted to the preferred operations angle, ranging from horizontal to perpendicular.
It sends a pleasant breeze to a wide range in the room by swinging the louver to right and left automatically Louver angle can be fixed at any desired position.
ELECTRICITYSAVING UPTO
47%
Increase Your Comfort
LONG REACHAIR FLOW
HIGH CAPACITYMACHINE
Increase Your Comfort
LONG REACHAIR FLOW
UP/DOWN
Jet air flow technology gives long reach airflow upto 50 ft. for 1.5 times bigger coverage compared to conventional AC.
LATERALSWING
11
CUSTOMER FRIENDLYFUNCTIONS
SRK25CSS-S6/A (2.2 Ton)SRK20CSS-S6/A (1.6 Ton)
60feet*56feet*
We have designed the machines using higher capacity compressor + Bigger Condensor Unit for maximum heat rejection for better cooling & higher energy efficiency, thereby we claim for Maximum Cooling Capacities.
SRK24YRV-S6 (2.2 Ton)
-
New Louver:
POSITION OF INSTALLATION:You can set the vertical louver movement at the time of installation to avoid the short cyclingof cool air when AC indoor unit is installed in extreme right or left of the area to be airconditioned.
Due to redesigned size and shape, the new louver has been increased in surface area by 80%. In addition to increase of air flow volume, it has improved controllability of swinging to right and left.
New Louver
POSITION OFINSTALLATION
CLEAN AIRSelf Clean Operation:“Self Clean Operation” is initiated after 2 hours of the unit stopping operation Users can select whether this mode is utilized or not.
Anti Micro Bial Fan: The blower fan has undergone anti- microbial treatment of resist mold and germs, making the system clean and state. Foul odors and molds, ets. Which can occur when an air conditioning system is not in operation are prevented.
SELF CLEANOPERATION
12
24- Hours ION:The air conditioner main body employs a tourmaline- coated sheet. The sheet generates negative ions around the clock. Even when the air conditioner is not running, it generates as many negative ions (2,500- 3,000/cc) as a forest, stream or fall does, allowing you to experience them without incurring any electricity charges.
3D AIR
3D AUTO
Natural Enzyme Filter:Highest disease disinfection efficiency Natural Enzyme Filter with a working mechanism of MHI Air Conditioner to suck up the disease contained air to pass into the Natural Enzyme Filter. The function of the Natural Enzyme filter will then do its duty to destroy the Cell Walls, and when the Cell Walls have been destroyed, all diseases will then die from the natural mechanism, resulting in sending out the safe and pure air from the MHI Air Conditioner.
Solar Filter:Recyclable filter because of its repeatedly restorable deodorizing power. It can keep air fresh by deodorizing at molecules causing odors plentiful in the room. As its deodorizing power can be restored only by washing with water and dry under the sun, it is an Recyclable deodorizing filter usable repeatedly.
Allergen Filter:
The filter breaks down the pollen, lice and all allergens that live on cat skins, etc and deactivates them.
ENZYME
FILTER
SOLARFILTER
FILTER
ALLERGENALLERGEN
ANTI MICROANTI MICROBIAL FANBIAL FAN
3D AIR
3D AUTO
Anti Bacterial Filter : Anti Bacterial Filter is a washable nylon wire mesh filter used for filtering the room air, having dust & common bacteria of 40-50 microns. There by making room air clean & free of bacteria.
ANTI BACTERIAL ANTI BACTERIAL FILTERFILTER
-
13
CONVENIENT & ECONOMY FUNCTION
Auto Restart:
Dry Operation: The unit dehumidifies the room by intermittent cooling operation.
MC (Microcomputer- Operated Defrosting):
Power blackout auto restart function is a function that records the operational status of the air- conditioner immediately prior to it being switched off by a power cut and then automatically resumes operations at that point after the power has been restored.
Economy:
Backup Switch:
The unit realized effective energy saving operation, while still keeping a comfortable cooling and heating.
This mode automatically eliminates frost, and helps minimize excessive operation in other modes.
On the main unit, these is a backup on/off switch, which is useful when you can’t use remote control or batteries are.
AUTORESTART
ECONOMY
DRY
BACK-UPSWITCH
BACK-UPSWITCH
COMFORTABLE FUNCTION:
Hi Power Cooling:
Auto Flap Mode:
Automatic:The air conditioner automatically selects from among heating, cooling and dry operations.
The unit can operate continuously in “HI POWER” mode for 15 minutes. This mode is convenient to reach the desired temperature quickly.
Fuzzy Auto Mode:
Whatever the operating mode is, the unit automatical ly selects the optimal angle.
Automatically, the unit determines its operating mode and temperature setting based on a fuzzy calculation, and adjusts the inverter frequency.
Memory Flap:While the flap is swinging, it can be stopped at any angle desired. The flap returns to the position that it was in when operation last stopped.
POWER FULL
COOLING
AUTO
AUTOFLAP
MEMORY FLAP
-
14
MAINTENANCE & PREVENTION
100% Copper:
TIMER
CONTROL
Cordless Remote Control
Sleep Mode:
Self Diagnostic:
On Timer:
Off Timer:
On/Off Timer:
In the Case, when air conditioner malfunction, an internal Micro-Computer Automatically runs Self Diagnosis function displays the flashing LED on the indoor unit and the User is able to identify the problem by referring the user’s manual troubleshooting table and inform the problem.
This facility enables the operation to start a little earlier, so that the room approaches optimum temperature at ON time when the operation is started by ON- TIMER. Thus it will try to be of the temperature you want, When you
The room temperature is automatically controlled during the set sleep mode period, ensuring that room temperature will not get too cold or too hot.
The unit stops automatically during the set sleep mode period. Ensuring that room temperature will not get too cold or too hot.
By combining a start timer with a stop timer, you can register two of the day repeatedly.
Longer Refrigerant Pipe Length:
Long Distance piping flexibility allows the outdoor unit to be placed far from the indoor unit. This adds to convenience and facilitates easy installation of the ACs.
Luminous Button:“Luminous button” in remote controls even “glows in the dark”. It is possible to operate all desired functions of the unit with the click of a button.
UPTO80 FEET
LONGERREFRIGERANTPIPE LENGTH
LUMINOUS
BUTTON
OFF TIMER
SELFDIAGNOSTIC
COPPER
100%
ON TIMER
SLEEP
Detachable:The air inlet panel on the indoor unit opens and closes easily, making filter cleaning simple. The suction panel can also be removed.
DETACHABLE
All the Models uses 100% copper pipe in Condensor coil and the Evaporator coil for maintenance free durable life and for better heat transfer.
Made in Thailand
-
15
HYBRIDAIRCONDITIONER
+ECO SMART
*47%
Presenting India’s Highest Energy Saving 1.5 Ton Eco Smart Hybrid AC with R410A Refrigerant & with Maximum 5.04* EER.
3D AIR
Increase Your Comfort
LONG REACHAIR FLOW
AUTOFLAP
MEMORY FLAP
UP/DOWN
3D AUTO
POSITION OFINSTALLATION
LATERALSWING
Comfortable Air Flow Functions
DETACHABLE
Maintenance
SELFDIAGNOSTIC
Clean Air
AUTO
Comfortable Function
POWER FULL
COOLING
Convenient & Economy Functions
DRYECONOMY
AUTORESTART
LUMINOUS
BUTTON
SWITCHBACK-UP UPTO
80 FEET
LONGERREFRIGERANTPIPE LENGTH
Others
SELF CLEANOPERATION
New Louver
COPPER
100%
SOLARFILTER
ENZYME
FILTER ANTI MICROANTI MICROBIAL FANBIAL FAN
R410AECO-FRIENDLY
NEW
Compact
SRK20CSS-S6/A / SRK25CSS-S6/A
SRK21CNS-S6
High Air Flow
-
16
Refrigerant Pipe Length
SRK20CSS-S6/A / SRK21CNS-S6 SRK25CSS-S6/A
* Cooling Capacity is derived Maximum during evening & night when the temperature is less than 35ºC** Under Standard Installation & Lab Test Condition*** Check for design condition and corresponding parameters like roof / window exposed to direction sunlight, of the area to be Air- conditioned. Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without any prior notice
SRK20CSS-S6/A
SRK20CSS-S6/A
SRC20CSS-S6/A
Indoor Unit
Outdoor Unit
BEE Star Rating
SPECIFICATIONS
Unit
MODEL
SRK25CSS-S6/A
SRK25CSS-S6/A
SRC25CSS-S6/A
5 STAR 5 STAR
+HYBRID - HEAVY DUTY AC (R410A)
Compressor Type
Power Source
Maximum Cooling Capacity * Watts
BTU/h
BEE Rated Cooling Capacity W
BTU/h
Input Power ** ( Minimum ~ Maximum)
BEE Rated EER / COP
Current ( minimum ~ maximum ) **
Dimension (H x W x D)Outdoor Unit
WeightOutdoor Unit
Air Flow ( CMH )
Long Reach AirFlow Upto
Self Diagnosis Function
Sound Level (H/M/L)
Louver Swing
Special Filter
Blower Fan
DC Fan Motor Speed
Refrigerant
Refrigerant Injection in Coil
Refrigerant PipingGas Line
Main Power Supply to
Connecting wiring
Area Coverage ***
Super Tropical - Return Cooled Rotary
1 Phase, 220 / 230 V, 50 Hz
Ton 1.6
6154
21000
Maximum EER / COP * W/w 4.92
Ton 1.6
5950
20301
watts 1250 ~ 1485
W/w 4.01
5.6 ~ 6.6A
Indoor Unit mm
mm 640 x 850 (+65) x 290
Indoor Unit Kgs 17
Kgs 44
Indoor Unit 1350
Indoor Unit Feet 56
Indoor Unit Yes
Indoor Unit dB
Indoor Unit 3D + 3D AUTO
Indoor Unit
Indoor Unit Anti - Micro Bial
Indoor Unit
R410A
Indoor Unit 5 Point - Multi Port
mm 6.35 ( 1/4" )
15.88 ( 5/8" )22.5 mm x 3 cores (including earthing cable )2
1.5 mm x 4 cores (including earthing cable )B/w IDU & ODU
Sq.Feet 172 ~ 280 300 ~ 450
mm
Liquid Line
339 x 1197 x 262
2.2
7700
26272
4.28
2.17
7625
26017
1800 ~ 2050
3.72
8.0 ~ 9.2
750 x 880 (+88) x 340
17
60
1450
60
339 x 1197 x 262
43 / 40 / 37 46 / 42 / 39
Enzyme + Photocatalytic Deodorizing Filter + Anti Bacterial
Auto / Powerful / High / Med / Low/ Dry
3m /hr
Outdoor Unit
SRK21CNS-S6
SRK21CNS-S6
SRC21CNS-S6
5 STAR
1.6
6154
21000
5.04
1.5
5300
18083
1220 ~ 1460
3.63
5.5 ~ 6.5
640 x 850 (+65) x 290
15
43
1100
45
309 x 890 x 251
44 / 41 / 38
172 ~ 200
SRC20CSS-S6/A / SRC21CNS-S6 SRC25CSS-S6/A
-
HEAVY DUTYAIRCONDITIONER
ECO SMART
Presenting India’s Highest Energy Saving 1.1 Ton Eco Smart Heavy Duty AC with R410A Refrigerant & with Maximum 3.96* EER.
*47%
R410AECO-FRIENDLY
SRK10CRS-S6 / SRK13CRS-S6
3D AIR
Increase Your Comfort
LONG REACHAIR FLOW
AUTOFLAP
MEMORY FLAP
UP/DOWN
3D AUTO
POSITION OFINSTALLATION
LATERALSWING
Comfortable Air Flow Functions
DETACHABLE
Maintenance
SELFDIAGNOSTIC
Clean Air
AUTO
Comfortable Function
POWER FULL
COOLING
Convenient & Economy Functions
DRYECONOMY
AUTORESTART
LUMINOUS
BUTTON
SWITCHBACK-UP UPTO 80M
LONGERREFRIGERANTPIPE LENGTH
Others
SELF CLEANOPERATION
New Louver
COPPER
100%
SOLARFILTER
ENZYME
FILTER ANTI MICROANTI MICROBIAL FANBIAL FAN
SILENT
17
SRK05CRS
2D AIR
Increase Your Comfort
LONG REACHAIR FLOW
AUTOFLAP
MEMORY FLAP UP/DOWN
Comfortable Air Flow Functions Maintenance
SELFDIAGNOSTIC
AUTO
Comfortable Function
POWER FULL
COOLING
Convenient & Economy Functions
DRYECONOMY OFF TIMER
AUTORESTART
BACK-UPSWITCH
BACK-UPSWITCH
Others
LUMINOUS
BUTTONCOPPER
100%
FUN TIMER HI
POWER ECO
ON/OFF
ON/OFF
RUN
TIMER
-
Refrigerant Pipe Length
SRK10CRS-S6 / SRK13CRS-S6
SRK10CRS-S6
Indoor Unit SRK10CRS-S6 SRK13CRS-S6
Outdoor Unit
BEE Star Rating
Refrigerant Control & Expansion
Compressor Type
Power Source
Maximum Cooling Capacity * Watts
BTU/h
BEE Rated Cooling Capacity W
BTU/h
Input Power **
BEE Rated EER / COP
Current ( minimum ~ maximum ) **
Dimension (H x W x D)Outdoor Unit
WeightOutdoor Unit
Air Flow (CMH)
Long Reach AirFlow Upto
Self Diagnosis Function
Sound Level (H/M/L)
Louver Swing
Special Filter
Blower Fan
DC Fan Motor Speed
Refrigerant
Refrigerant Injection in Coil
Refrigerant PipingGas Line
Main Power Supply to
Connecting wiring
Area Coverage ***
SPECIFICATIONS ECO SMART - HEAVY DUTY AC ( R410A )
Unit
MODEL
SRK13CRS-S6
SRC10CRS-S6 SRC13CRS-S6
5 STAR 5 STAR
Dual Capillary Expansion
Super Tropical - Return Cooled Rotary
1 Phase, 220 / 230 V, 50 Hz
Ton
Maximum EER / COP * W/w
Ton
watts
W/w
0.9 1.12
3077 3957
10500 13500
4.15 3.96
0.8 1.1
2700 3600
9212 12283
550 ~ 740 700 ~ 1000
3.65 3.60
3.0 ~ 3.3 4.0 ~ 4.7A
Indoor Unit mm 268 x 790 x 213
mm
Indoor Unit Kgs
Kgs 3430
Indoor Unit
Indoor Unit Feet
4.68
0.5
1758
6000
0.5
1465
5000
300 ~ 375
3.90
1.5 ~ 1.8
262 x 615 x 210
435x645(+50)x275
6
20
510
8
2D
540 x 780 x 290 595 x 780 x 290
9.5 9.5
650 750
15 20
Indoor Unit Yes
Indoor Unit dB 38 / 34 / 31
Indoor Unit 3D + 3D AUTO
Indoor Unit Enzyme + Solar + Anti - Bacterial Filter
Indoor Unit Anti - Micro Bial
Indoor Unit Auto / Powerful / High / Med / Low / Dry
R410AR410
Indoor Unit 4 Point - Multi Port2 Point - Multi Port
mm 6.35 ( 1/4" )
Indoor Unit
B/w IDU & ODU
Sq.Feet
9.52 ( 3/8" )2
Indoor Unit - 1.5mm X 3 cores
50 ~ 75
9.52 ( 3/8" ) 12.7 ( 1/2" )
2 1.5 mm x 4 cores (earthing cable )
100 ~ 140 129 ~ 172
22.5 mm x 3 cores (earthing cable )
mm
Liquid Line
* Cooling Capacity is derived Maximum during evening & night when the temperature is less than 35ºC** Under Standard Installation & Lab Test Condition*** Check for design condition and corresponding parameters like roof / window exposed to direction sunlight, of the area to be Air- conditioned. Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without any prior notice
3m /hr
18
SRK05CR-S
SRK05CR-S
SRC05CR-S
SRK05CRS
4m
2m
SRC05CR-S
SRC10CRS-S6 / SRC13CRS-S6
38 / 34 / 3138 / 34 / 26
YesYes
-
19
ECO SMART
SRK18CS-S6
HEAVY DUTYAIRCONDITIONER
SRK24CS-S6/A
*37%
R410AECO-FRIENDLY
Presenting India’s Highest Energy Saving 1.5 Ton Eco Smart Heavy Duty AC with R410A Refrigerant & with Maximum 3.41* EER.
2D AIR
Increase Your Comfort
LONG REACHAIR FLOW
AUTOFLAP
MEMORY FLAP
UP/DOWN
Comfortable Air Flow Functions
DETACHABLE
Maintenance
SELFDIAGNOSTIC
AUTO
Comfortable Function
POWER FULL
COOLING
Convenient & Economy Functions
DRYECONOMY
AUTORESTART
LUMINOUS
BUTTON
SWITCHBACK-UP UPTO
80 FEET
LONGERREFRIGERANTPIPE LENGTH
Others
New Louver
COPPER
100%
SRK12CR-S6
-
20
Refrigerant Pipe Length
SRK18CS-S6 /
SRK24CS-S6/A
* Cooling Capacity is derived Maximum during evening & night when the temperature is less than 35ºC** Under Standard Installation & Lab Test Condition*** Check for design condition and corresponding parameters like roof / window exposed to direction sunlight, of the area to be Air- conditioned. Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without any prior notice
SRC12CR-S6
SRK18CS-S6
Indoor Unit SRK18CS-S6 SRK24CS-S6/A
Outdoor Unit
BEE Star Rating
Refrigerant Control & Expansion
Compressor Type
Power Source
Maximum Cooling Capacity * Watts
BTU/h
BEE Rated Cooling Capacity W
BTU/h
Input Power **
BEE Rated EER / COP
Current ( minimum ~ maximum ) **
Dimension (H x W x D)Outdoor Unit
WeightOutdoor Unit
Air Flow ( CMH )
Long Reach AirFlow Upto
Self Diagnosis Function
Sound Level (H/M/L)
Louver Swing
Special Filter
Blower Fan
DC Fan Motor Speed
Refrigerant
Refrigerant Injection in Coil
Refrigerant PipingGas Line
Main Power Supply to
Connecting wiring
Area Coverage ***
SPECIFICATIONS ECO SMART - HEAVY DUTY AC ( R410A )
Unit
MODEL
SRK24CS-S6/A
SRC18CS-S6 SRC24CS-S6/A
3 STAR
Dual Capillary Expansion
Super Tropical - Return Cooled Rotary
1 Phase, 220 / 230 V, 50 Hz
Ton 1.5 2.0
5569 7400
19000 25248
Maximum EER / COP * W/w 3.41 3.94
Ton 1.5 2.0
5280 7300
18015 24907
watts 1400 ~ 1615 1880 ~ 2180
W/w 3.27 3.35
6.5 ~ 7.1 8.5 ~ 9.5A
Indoor Unit mm 309 x 890 x 251
mm
Indoor Unit Kgs 14 17
Kgs 40 47
Indoor Unit 1050 1300
Indoor Unit Feet 40 56
Indoor Unit
Indoor Unit dB 45 / 43 / 41
Indoor Unit 2D
Indoor Unit Anti Bacterial
Indoor Unit
Indoor Unit Auto / Powerful / High / Med / Low
R410A
Indoor Unit 5 Point - Multi Port
mm 6.35 ( 1/4" )
15.88 ( 5/8" )22.5 mm x 3 cores ( including earthing )
B/w IDU & ODU 21.5 mm x 4 cores ( including earthing )
Sq.Feet 172 ~ 225 200 ~ 300
mm
Liquid Line
4 STAR
339 x 1197 x 262
640 x 850 ( + 65 ) x 290
3m /hr
Outdoor Unit
Non Anti - Micro Bial
Yes
SRK12CR-S6
SRK12CR-S6
SRC12CR-S6
3 STAR
1.0
3810
13000
3.38
1.0
3500
12000
3.29
4.0 ~ 5.0
262 x 769 x 210
8.5
31
700
15
36 / 32 / 29
595 x 780(+ 62)x 290
850 ~ 1065
6.35 ( 1/4" )
12.7 ( 1/2" )
129 ~ 172
46 / 42 / 39
SRC24CS-S6/ASRC18CS-S6
SRK12CR-S6
5m
-
21
Comfortable Air Flow Functions
EEV
DETACHABLE
Maintenance
SELFDIAGNOSTIC
Clean Air
AUTO
Comfortable Function
POWER FULL
COOLING
Convenient & Economy Functions
DRYECONOMY OFF TIMER
AUTORESTART
BACK-UPSWITCH
BACK-UPSWITCH
UPTO 80M
LONGERREFRIGERANTPIPE LENGTH
Others
COPPER
100%
SELF CLEANOPERATION
SOLARFILTER
ENZYME
FILTER ANTI MICROANTI MICROBIAL FANBIAL FAN
LUMINOUS
BUTTON
UP/DOWN
POSITION OFINSTALLATION
LATERALSWING
New Louver
3D AIR
Increase Your Comfort
LONG REACHAIR FLOW
AUTOFLAP
MEMORY FLAP
3D AUTO
SRK10YL-S/ SRK13YL-S / SRK18YL-S
SRK24YRV-S6
InverterFUN TIMER
HI POWER ECO
ON/OFF
ON/OFF
2.2
& ISEER of 4.75
-
22
Refrigerant Pipe Length
SRK10YL-S / SRK13YL-S
SRC18YL-SSRC10YL-S / SRC13YL-S
New Inverter Vector ControlNew Inverter Control has applied new advanced technology of Vector control and has realized high efficiency.• Smooth operation from low speed to high speed • Energy efficiency is further improved in low speed range.• Smooth Sine Voltage Wave form are attained
30m
20mSRK24YRV-S6
ISEER = INDIAN SEASONAL ENERGY EFFICIENCY RATIO
SPECIFICATIONS
SRK10YL-S SRK13YL-S SRK18YL-S
MODEL SRK10YL-S SRK13YL-S SRK18YL-S
SRC10YL-S SRC13YL-S SRC18YL-S
0.80 1.1 1.6
5 Star 5 Star 4 Star 5 Star
9861 13252 19609 26815
9247 12454 18425 25198
5203 6995 9646 13460
2890 3884 5747 7859
2710 3650 5400 7385
1525 2050 2827 3945
670 975 1560
253 369 582
4.3 3.7 3.5 3.7
6.0 5.6 4.9 5.1
ISEER 5.41 5.00 4.49A 0.5 ~ 3.0 0.65 ~ 4.3 0.87 ~ 7.0
Indoor Unit mm
Outdoor Unit mm 540 x 780(+62) x 290 540 x 780(+62) x 290 595 x 780(+62) x 290
Indoor Unit Kgs 9.0 9.0 10.0
Outdoor Unit Kgs 29 32 35
Cooling Coil Row Indoor Unit No.s 2 3 3
Air Flow (CMH) Indoor Unit m3/hr 600 790 1000Long Reach Air Flow Upto Indoor Unit Feet 15 15 17
Self Diagnosis Function Indoor Unit Yes Yes Yes
Sound Level (H/M/L) Indoor Unit dB 39 / 30 / 22 39 / 30 / 22 45 / 38 / 26
Louver Swing Indoor Unit
Special Filter Indoor Unit
Fan Indoor Unit
DC Fan Motor Speed Indoor Unit
Liquid Line mm
Gas Line mm 9.52 ( 3/8" ) 9.52 ( 3/8" ) 12.7 ( 1/2" )
Main Power Supply to Outdoor Unit
Connecting wiring B/w IDU & ODU
Area Coverage *** Sq.Feet 80 ~ 140 130 ~ 170 150 ~ 200
772
2000
Twin Rotary
2.2
SRC24YRV-S6
iPM ( Intelligent Power Module )
1 Phase, 220 / 230 V, 50 Hz
7 ~ 15 RPM - Using Vector Control Technology
Motorized Electronic Expansion Valve for Variable Refrigerant Flow
339 x 1197 x 262
1.52 ~ 9.0
4.75
1450
3
61
18.5
750 x 880(+88) x 340
ECO SMART - HYPER INVERTER ( R410A ) - COOLING ONLY
Unit SRK24YRV-S6
Indoor Unit SRK24YRV-S6
Outdoor Unit
Tonnage
Compressor Type Super Tropical - DC PAM Inverter - Return Cooled - Rotary
BEE Star Rating
VFD - Variable Frequency Drive Inverter Vector Control Technology for Higher Efficiency
Minimum Compressor RPM
Refrigerant Volume Control Using
Rated Cooling Capacity ( 100% Load )
Rated Cooling Capacity ( 50% Load )
Maximum Cooling Capacity
LCD Remote Control ( iPM Controller )
Power Source
Maximum Cooling Capacity
BTU/hr
WattsRated Cooling Capacity ( 100% Load )
Rated Cooling Capacity ( 50% Load )
Rated Power Consumption (100% Full Load)watts
Rated Power Consumption ( 50% Half Load)
Rated EER / COP (100% Load )
Rated EER / COP ( 50% Load )
Rated Indian Seasonal Energy Efficiency
W/w
Current ( 100% Load Capacity )
Dimension (H x W x D)268 x 790 x 224
Weight
60
Yes
41/38/34/25(Silent
Mode)
3D + 3D AUTO
Enzyme + Solar + Anti Bacterial
Anti - Micro Bial Fan
Auto / Powerful / High / Medium / Low / Dry/ (Ultra Low-in-silent mode in SRK24YRV- S6)
Refrigerant R410A
Refrigerant Injection in Coil 4 Point - Multi Port
250 ~ 450
Refrigerant Piping Thickness:18Gauge(1mm)
6.35 ( 1/4" )
15.88 ( 5/8" )
2.5 mm2 x 3 cores (including earthing)
1.5 mm2 x 4 cores (including Earthing)
* Cooling Capacity is derived Maximum during evening & night when the temperature is less than 35ºC ** Under Standard Installation & Lab Test Condition*** Check for design condition and corresponding parameters like roof / window exposed to direction sunlight, of the area to be Air- conditioned. Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without any prior notice
268 x 790 x 224 268 x 790 x 224
SRK18YL-S
-
TOWARDSA BETTER
FUTURETOGETHER
RE TA OC L LR E FRM EEOT NS oU .C
1 58 50 00 0 1 0 2
Our Motto “Customer Satisfaction Index No.-1”
Sales, Service & Marketing Headquarter (India)
Mitsubishi Heavy Industries- Mahajak Air Conditioners Co.Ltd. Lat krabang Industries Estate, Phase 3, 200 Moo 4, Chalongkrung Road, Lamplatiew, Lat krabang, Bangkok Thailand 10520
PRECAUTIONS
Sales, Service Office in India
IAPL House, 2/8, West Patel Nagar Near Patel Nagar Metro Station- New Delhi- 110008 (INDIA) Tel.: 011-47230000-99, Toll Free No.: 1800 102 0055 Email: [email protected], Website: www.iaplgroup.com
IAPL GROUP PVT. LTD.
Ludhiana
Faridabad
Ghaziabad
Panchkula
Mohali
Vijayawada
J&K
Chandigarh
Agra
Gwalior
Bhopal
Jabalpur
Jharkhand
RanchiVadodara
Nashik
Mangalore
Thrissur
AHMEDABAD : 9978991675, BANGALORE : 9849102323, BHOPAL : 9630098716, BHUBANESWAR : 8697706531, PATNA : 8697744670, CHENNAI : 8939991872, COCHIN : 9946446067, COIMBATORE : 9645134000, DEHRADUN : 8826899163, DELHI : 8826392381 DELHI & NCR : 8826392374, NOIDA : 8826899163, GHAZIABAD : 8826899163, HARYANA : 8929602345, HYDRABAD : 9885651712, INDORE : 9630033341, J & K : 9915009212, JAIPUR : 9983361035, KOLKATA : 8697744670, LUCKNOW : 8826899163, AGRA : 8006003003, GWALIOR : 9630098716, MUMBAI : 8879599905, NAGPUR : ,NASIK : , PUNE : , RAJKOT : 9727731456, RAIPUR : 9821197915, PUNJAB : 9915009212, LUDHIANA : 8283843670, SURAT : 9978996351, THRISSUR : 9946446067, VADODARA : 9978991675, JABALPUR : 9630098716, VIJAYAWADA : 8008156000
9657004567 84487039618448703961
(Wholly-owned subsidiary of MITSUBISHI HEAVY INDUSTRIES, LTD.)
Page 1Page 2Page 3Page 4Page 5Page 6Page 7Page 8Page 9Page 10Page 11Page 12Page 13Page 14Page 15Page 16Page 17Page 18Page 19Page 20Page 21Page 22Page 23Page 24