2014 GENERAL CATALOGUE - Medal Aircon … · good quality existing R22 pipe work to be re-used...

64
The air conditioner works in heat pump mode even when outdoor temperatures are as low as -20°C or -15°C. Down to -20°C in heating mode OUTDOOR TEMPERATURE Internet Control is a next generation system providing a user-friendly remote control of air conditioning or heat pump units from everywhere, using a simple Android or iOS smartphone, tablet or PC via internet. Internet Control Ready INTERNET CONTROL OPTIONAL Inverter plus products improve on the characteristics of standard Inverter range by over 20%. This means 20% less consumption and 20% OFF your electric bill. A Inverter plus is also A class on cooling and heating mode. Energy saving Econavi features intelligent Human Activity Sensor and new Sunlight Sensor technologies that can detect and reduce waste by optimising air conditioner operation according to room conditions. With just one touch of a button, you can save energy efficiently with uninterrupted cooling, comfort and convenience. Up to 28% energy savings (cooling) Exceptional Seasonal Cooling Efficiency based on the new ErP regulation. Higher ESEER ratings mean greater efficiency. Save all the year while cooling! 6.80 A++ SEER SEASONAL ENERGY EFFICIENCY RATIO Exceptional Seasonal Heating Efficiency based on the new ErP regulation. Higher SCOP ratings mean greater efficiency. Save all the year while heating! 4.00 A+ SCOP SEASONAL COEFFICIENT OF PERFORMANCE The air conditioner works in cooling only mode with an outdoor temperature of -15°C. Down to -15°C in cooling mode OUTDOOR TEMPERATURE Environmentally friendly refrigerant R410A 5 year compressor warranty R410A. Environmentally friendly refrigerant. 5 years warranty. We guarantee the compressors in the entire range for five years. Only for PRO partners. The communication port is integrated into the indoor unit and provides easy connection to, and control of, your Panasonic heat pump to your home or building management system. The Panasonic renewal system allows good quality existing R22 pipe work to be re-used whilst installing new high efficiency R410A systems. Easy control by BMS CONNECTIVITY Possible to use on R22 pipings R22 RENEWAL PACi Standard for economy and value With high quality design and engineering, the PACi Standard is the perfect solution for projects which demand quality on a limited budget. In addition, its compact size and light weight make it ideal for installations with limited space including small commercial and residential applications. PACi Elite, Newly designed next generation commercial! Energy-saving concept. The use of energy saving designs for the structure of fans, fan motors, compressors and heat exchangers resulted in a high COP value, ranked as one of the top classed in the industry. In addition, use of highly efficient R410A refrigerant reduces CO 2 emission and lowers operating costs. 118

Transcript of 2014 GENERAL CATALOGUE - Medal Aircon … · good quality existing R22 pipe work to be re-used...

The air conditioner works in heat pump mode even when outdoor temperatures are as low as -20°C or -15°C.

Down to

-20°C inheating mode

OUTDOORTEMPERATURE

Internet Control is a next generation system providing a user-friendly remote control of air conditioning or heat pump units from everywhere, using a simple Android or iOS smartphone, tablet or PC via internet.

InternetControlReady

INTERNET CONTROL

OPTIONAL

Inverter plus products improve on the characteristics of standard Inverter range by over 20%. This means 20% less consumption and 20% OFF your electric bill. A Inverter plus is also A class on cooling and heating mode.

Energy saving

Econavi features intelligent Human Activity Sensor and new Sunlight Sensor technologies that can detect and reduce waste by optimising air conditioner operation according to room conditions. With just one touch of a button, you can save energy efficiently with uninterrupted cooling, comfort and convenience.

Up to 28%energy savings

(cooling)

Exceptional Seasonal Cooling Efficiency based on the new ErP regulation. Higher ESEER ratings mean greater efficiency. Save all the year while cooling!

6.80 A++SEER

SEASONAL ENERGY EFFICIENCY RATIO

Exceptional Seasonal Heating Efficiency based on the new ErP regulation. Higher SCOP ratings mean greater efficiency. Save all the year while heating!

4.00 A+SCOP

SEASONAL COEFFICIENT OF PERFORMANCE

The air conditioner works in cooling only mode with an outdoor temperature of -15°C.

Down to

-15°C incooling mode

OUTDOORTEMPERATURE

Environmentallyfriendlyrefrigerant

R410A

5 yearcompressorwarranty

R410A. Environmentally friendly refrigerant.

5 years warranty.We guarantee the compressors in the entire range for five years.Only for PRO partners.

The communication port is integrated into the indoor unit and provides easy connection to, and control of, your Panasonic heat pump to your home or building management system.

The Panasonic renewal system allows good quality existing R22 pipe work to be re-used whilst installing new high efficiency R410A systems.

Easycontrolby BMS

CONNECTIVITY

Possibleto use on

R22 pipings

R22 RENEWAL

PACi Standard for economy and valueWith high quality design and engineering, the PACi Standard is the perfect solution for projects which demand quality on a limited budget. In addition, its compact size and light weight make it ideal for installations with limited space including small commercial and residential applications.

PACi Elite, Newly designed next generation commercial!Energy-saving concept. The use of energy saving designs for the structure of fans, fan motors, compressors and heat exchangers resulted in a high COP value, ranked as one of the top classed in the industry. In addition, use of highly efficient R410A refrigerant reduces CO

2 emission and lowers

operating costs.

118

WELCOME TO THE COMMERCIAL

RANGE

Here are some of your new air conditioner’s major features.Panasonic has developed an impressive range of highly efficient Commercial Air Conditioners. This range confirms our commitment to the environment. Our Inverter compressors optimise performance and thus reduce energy costs.

SEASONALEFFICIENCY

119

COMMERCIAL

Energy saving

PACi StandardFor economy and valueWith high quality design and engineering, the PACi Standard is the perfect solution for projects which demand quality on a limited budget. In addition, its compact size and light weight make it ideal for installations with limited space including small commercial and residential applications.

PACi EliteNewly designed next generation of commercial air conditionningEnergy-saving concept. The use of energy saving design for the structure of fans, fan motors, compressors and heat exchangers resulted in high COP value which ranked as one the top class in the industry. In addition, use of highly efficient R410A refrigerant reduces CO

2 emission and lowers operating costs.

120

PACi Standard· Good balance, system cost vs energy efficiency· Top class ESEER/SCOP as a Standard Inverter category

ESEER: A++ / SCOP: A+ at 10.0 kW (in Cassette 90x90)· Interchangeable controller with ECOi· Compact outdoor units· Twin connection possible· Cooling operation up to -15°C· Heating operation up to -10°C

New PACi Elite· Meeting all necessary safety approvals to ensure quality and safety· Top-class ESEER: A++ / SCOP: A+ at 10.0 kW (in Cassette 90x90 and

Ceiling)· Cooling operation is possible when outdoor temperature as high as 46°C· DC inverter technology combined with R410A for excellent efficiency· Cooling operation is possible when outdoor temperature as low as -15°C· Heating operation is possible when outdoor temperature as low as -20°C· Compact outdoor units· Auto restart from outdoor unit· Twin, Triple and Doble-Twin connection possible

A++SEER

A+SCOP

SEASONALEFFICIENCY

PRODUCT FOLLOWS THE NEW ECODESIGN REQUIREMENTS

121

COMMERCIAL PACi ELITE / STANDARDNEW

PACi Standard: outdoor unitMore compactThe outdoor unit is much more compact than the previous model. The slim and lightweight design means the PACi outdoor unit can be installed in a number of situations.

* Only for U-100PEY1E8, U-125PEY1E8, U-100PEY1E5 and U-125PEY1E5.

-15%SMALLER

PACi Elite: outdoor unitWide operating range· Cooling operation is possible when outdoor temperature as low as -15°C· Cooling operation is possible when outdoor temperature as high as 46°C· Heating operation is possible when outdoor temperature as low as -20°CThe remote control temperature setting offers a range from 18°C to 30°C.

-20 -15 -10 -5 0 5 10 15 20 25 30 35 40 46 50

HEATING: -20°C WB / 24°C WBCOOLING: -15°C DB / 46°C DB

Product Quality and SafetyAll Panasonic air conditioners undergo strict quality and safety tests before sale. This rigorous process includes obtaining all necessary safety approvals, to ensure that all air conditioners we sell are not only built to the highest market standards, but are also completely safe.

Quiet mode2, 4 or 6 dB can be reduced by different setting on your choice. External input signal is also available.

OLD MODELS(1,170 x 900 x 320)

ON THE 12,5 kW(996 x 940 x 340)

122

Demand Response Compliant (CZ-CAPDC3)This optional part allows demand control of the outdoor unit.Several level of settings are available:· Level-1, 2, 3 : 75 / 50 / 0 %· Level-1, 2 can be set in 40 - 100% (40, 45, 50…95, 100: each 5%)

Energy saving conceptThe use of energy saving designs for the structure of fans, fan motors, compressors and heat exchanges has resulted in a high COP value, ranked as one of the top classed in the industry. In addition, use of highly efficient R410A refrigerant reduces CO

2 emission and lowers operating costs.

1. Compact & highly efficient compressor. Large-capacity inverter compressor has been adopted. The inverter compressor is superior in performance with improved partial-load capacity.

2. Printed circuit board (P-LINK). To improve maintenance, the number of PCBs have been reduced to two.

3. DC fan motor. Considering load and outside temperature, the DC motor is controlled for optimum air volume.

4. New large diagonal (520 mm) air flow fan. The fan has been designed to reduce air turbulence and increase efficiency. As fan diameter has been increased to 520 mm, the air volume has been increased by 12% whilst maintaining a low sound level.

5. High-efficiency heat exchanger. The heat exchanger size and the copper tube sizes in the heat exchanger have been redesigned to increase efficiency.

Excellent ESEER and SCOP valuesPanasonic have a extremely high ESEER and SCOP values following the SBEM method (some other manufacturers may use another non official calculation method). Developed by BRE, SBEM (Simplified Building Energy Model) is the basis of non-domestic building energy calculations. Based on the National calculation method (NCM), it is used to determine compliance with Part L of the Building Regulations and is also used to provide Energy Performance Certification.

The annual energy consumption for all systems up to 12kW is calculated in accordance with the ErP directive.

Non-Domestic Building Services Compliance Guide provides information on various aspects of the calculation method, including those of Heat Pumps (Section 3), and Comfort Cooling (Section 9).

SCOP - Seasonal Coefficient of PerformancePart Load COP 25% 50% 75% 100%Ambient conditions 15°C 7°C 1°C -5°CWeighting factor 0.20 (a) 0.36 (b) 0.32 (c) 0.12 (d)

UK winter -5°C DB (outdoor temperature), 20°C WB (indoor temperature)

SEER - Seasonal Energy Efficiency RatingPart Load COP 25% 50% 75% 100%Ambient conditions 20°C 25°C 30°C 35°CWeighting factor 0.20 (a) 0.36 (b) 0.32 (c) 0.12 (d)

UK summer 21°C DB (outdoor temperature), 16°C WB (indoor temperature)

ESEER calculation corresponds with below conditions and power input of indoor units is not included.· Indoor temperature: 27°C DB / 19°C WB· Outdoor temperature conditions

Part load ratio 25% 50% 75% 100%Outdoor air temperature (°C DB) 20 25 30 35Weighting coefficients 0.23 0.41 0.33 0.03

· Formula : 0.23 x EER25% + 0.41 x EER50% + 0.33 x EER75% + 0.03 x EER100%.

Increased Piping Length for Greater Design FlexibilityAdaptable to various building types and sizes.Maximum piping length: 75m (10.0, 12.5, 14.0kW). 50m (6.0, 7.1kW).

Compact & Flexible-designThe slim and lightweight design means the PACi outdoor unit can be installed in a number of compact situations.As the unit only weighs 98 kg, it is easy to carry and easy to install.

Improved energy savingOperating efficiency has been improved using highly efficient R410A refrigerant, new DC inverter compressor, new DC motor and a new heat exchanger design.

4.50

4.00

3.50

3.00

2.50 10.0 kW 12.5 kW 14.0 kW 11.2 kW 14.0kW 16.0 kW

3.70

3.41

3.86

4.31

3.61

4.00

3.25

3.01

4.20

3.60

3.86

3.43

Current model in heating modeNew model in heating mode

Current model in cooling modeNew model in cooling mode

1. Compact & highly efficient compressor

2. Printed circuit board (P-LINK)

3. DC fan motor4. New large diagonal

(520 mm) air flow fan

5. High-efficiency heat exchanger

Maximum height difference

30 m

* 15m if the outdoor unit is below the indoor unit.

MAXIMUM TOTAL LENGTH: 75 m

DRM1 DRM2

CZ-CAPDC3

DRM3 C

Outdoor unit

Demand controller

Terminal block(supplied as optional kit)

Demand control terminal is available to control 0-50-75% of capacities.

SINGLE SPLIT PACi

1

3

5

4

2

123

COMMERCIAL PACi ELITE / STANDARD

Solutions for server roomsHigh efficiency products for 24/7 applicationsPanasonic has developed a complete range of solutions for server rooms which efficiently protect your servers, keeping them at an appropriate temperature even when the outdoor temperature is below -20°C.

Key points· From 2,5 kW to 5 kW with PKEA units· From 5 kW to 25 kW with PACi units· Backup function· Redundancy function· Alternative run function· Error information by dry contact· Operation even at -20°C outdoor temperature· Excellent performance with excellent ESEER· Product design for 24/7 operation

·· HHHHIIIIGGHH EENNNEERRGGGGYYYY

EEFFFFIICIIEENNCCYY

·· 2244//77 OOOPPEERRAATTIIOOOONN

124

High efficiency all the yearOn 24/7 operation, the performance of the air conditioning is a key factor.When the efficiency is high, the return on investment of such units is quickly reached.

Why is the Panasonic R2 Rotary Compressor so effi cient? 1. High Efficiency Motor The premium silicon steel motor meets

industry efficiency requirements.2. Improved Lubrication of High Volume Oil Pump The extended,

high volume oil pump in conjunction with a larger capacity oil reservoir provides superior lubrication.

3. Accumulator has Larger Refrigerant Capacity The larger accumulator accommodates generous refrigerant amounts needed in longer line length installations.

High durability for 24/7 operationIndoor Fan. Cross-Flow-Fan· High durability rolling bearings, large size (w105mm) fan· High efficiency blade· Random pitch blade (low sound)

CompressorDC2P Panasonic original compressor, with high efficiency and reliability.

1

2

3

ROTARY INVERTER COMPRESSOR

8,0

7,0

6,0

5,0

4,0

3,0

2,0

1,0

0 2,8 kW 3,2 kW 4,5 kW 5,0 kW 5,0 kW 6,0 kW 7,1 kW

PKEA PACi Elite

6,0

3,9

6,9

4,2

6,3

3,9

6,7

4,1

7,1

4,43,9

6,6

3,9

6,6

SCOPESEER

Interfaces to run 2 (for PKEA) or up to 3 (for PACi) units on Backup and alternative runPAW-SERVER-PKEA for PKEA

The PAW-SERVER-PKEA server room interface manages redundancy and backup of two PKEA units with two different selectable modes:· Plug and play by embedded redundancy and backup algorithm (no

external signal needed. Further details please refer to operation manual) · External (third party PLC) redundancy and backup management by dry

contactAll settings are possible without the need for a computer connection. A special Energy Saving Mode is selectable by deep switch (available only in plug and play mode). The level of remote control input prohibition can be set when external management is by dry contact.

PAW-PACR3 for PACi and ECOi Range

PAW-PACR3, in combination with one PAW-T10V on each indoor unit, allows the redundant operation of 2 (or 3) PAC-i or VRF indoor units. All units will be operated by programmable turns in order to achieve the same operating time (example turn every 8 hours with 24 hours).If the room temperature exceeds a freely set value, the 2nd (or 3rd) unit will be switched ON and an alarm will be activated.In combination with 1x PAW-T10V on each indoor unit, 2 or 3 PACi of ECOi can be programmed to run redundant.Display and Settings:· Possible to select next unit manually· Possible to reset operation· LED display shows operation status of the 2 or 3 units· Operation status output· Alarm LED and alarm output· Temperature limit can be set· Temperature hysteresis can be set· Room temperature is displayed· Time counter displayed

Cable maximum length 3 meters

each CN-CNT

Output Alarm SignalA unitB unit

(2 x dry contact maximum 12V)

Input ON/OFF SignalA unitB unit

(2 x dry contact maximum 12V)

Input PCB Special Settings1 x Connection port to PC

Jumper 2)Enable ON OFF dry

contact (maximum 12V)

Jumper 1)Energy Saving Function

Standard remote control

Output Run SignalA unitB unit

(2 x dry contact maximum 12V)

PAW-SERVER-PKEA

A B

4MODE

1/2 SET5 3 1

2 0

T10

Alarm contact Room thermostat External contacts

T10

PAW-PACR3

T10

125

COMMERCIAL

New wired remote controller with Econavi function controlEasy to use, attractive, clear design, with new demand control functions and energy consumption display! This useful feature makes this remote control unique!

DesignThe new CZ-RTC3 wired remote control is ideal for integration into the most demanding interior architectures.The touch panel features a very sleek and easy to use display, which with its compact display is only 120mm x 120mm x 16mm.

Display of informationThe information is mainly based on pictograms to ensure easy understanding.The minimal amount of text is available in 4 languages (English / German / French / Spanish / Italian).The screen is back lit to enable reading even during the night.

Easy Access to the menusWith the new pictograms, the navigation, the selection and the settings are simple and easy to follow.

Key Functions· Easy setup of the timer and settings of the indoor unit· Energy consumption display (only available with PACi units with the reference

ending with A)· Limitation of the energy consumption (Demand control) by timer.

126

Basic function (Operation display & indication)All functions are easily available on the remote controll.· OFF/ON timer · Weekly timer · Quiet operation · Remote control sensor · Operation prohibit · Filter sign · Energy saving · Centralized control indication · Mode change prohibit · Automatic temperature return · Temperature range limitation · OFF remind · Schedule demand control · Ventilation · Out Function

Example of easy access to the functions: Air direction setting1. Select “Air direction” and press “determine” key.2. Select the unit No. by up/down key.3. Select the flap position by up/down key.4. Press “Return” key to go back the Menu display.

Example of easy access to the functions : Weekly timer setting8 actions available per day. Total 56 actions per week can be set.1. Weekly timer menu display2. Setting for each day of the week3. Timer program setting of the day

Example of easy access to the functions: Energy consumption monitoring display per day, week, month and year (only available with PACi units)

Easy operation and quick access to all menus1. Set temperature will be selected, when any arrow button is touched.2. Select the item (Mode or Fan speed) by left/right key.3. Change the setting by up/down key.

Functions available on the CZ-RTC3

Control item Controllability Indoor UnitsAll PACi Only PACi

ending on A

Basic Operation Operation, Mode, Temperature setting, Airflow volume, Airflow direction

Timer function Time displayEasy ON/OFF timerWeekly Program timer

Energy saving Outing functionTemperature auto returnTemperature setting range limitationOFF remind Energy saving modeSchedule demand control —Energy monitoring —

Maintenance System failure information —Service contact registrationFilter sign (rest time display) & ResetAuto-address, Test runSensor value monitorSimple/Detail setting mode

Others Key lockVentilation fan controlDisplay contrast adjustmentRemote controller sensorQuiet operation mode —Prohibit setting control from Central controller

All specifications subject to change without notice.

Menu selection: 3 types (Day/Week/Year)of display are available.

Weekly Energy consumption: Power consumption of each day of the week can be checked.

Daily Energy consumption: Data is shown with Yesterday’s record.(Graph starts from 0 o’clock to 24 o’clock only.)

Annual Energy consumption: Power consumption of each month can be checked.

Name of the room (Max.16 characters)

Mode: Hot / Cool / Dry / Fan Auto

Status: Heating stand-by / Defrost operation / Stand-by (GHP system)

Set temperature

Time & Day of the week

Flap setting

Fan speed:H / M / L / Auto

1 2 3

1 2 3

127

COMMERCIALNEW

New Econavi SensorThe all new Econavi Sensor detects presence in the room, and quietly adapts the PACi or VRF air conditioning system in order to improve comfort and maximise energy savings.· Detects human activity and adjusts temperature by 2 degrees (up or down) to optimize comfort

and efficiency· If there is no activity detected for a set time, the Econavi will stop the unit or move to a new

temperature previously set· The Econavi device is installed independently of the indoor unit, and is located in the area

best suited for detection

ApplicationsSaving Energy for Offices: if the air conditioning is left on after the last employee leaves the office, Econavi will automatically react, reducing or stopping the system.Increased comfort in hotel rooms: when presence is detected in the room, the temperature is automatically adjusted to achieve best comfort.

Econavi function· Analyses room activity: Human activities and human heat· Modifies the capacity to adapt in real-time to the needs of the room

Key points· Compatible with Cassette, Wall Mounted, Hide Away and Ceiling · Sensor · Improves efficiency

· Better Comfort · Can be installed in the best place of the room for detection purposes.Available in October 2014.

Wired remote controller CZ-RTC3 with Econavi Sensor Control

Up to 28%energy savings

(cooling)

INCREASE

EFFICIENCY

BY 28%

INCREASE

COMFORT

128

Human detection area (2,5m height angle 30°)

1m 3m 5m 7m7m

-60°

-40°

-20°

40°

20°

60°

5m 3m 1m

Sensor location image

2,5 m

b (m)

1,8m Dead Zone

Approx 1m

Detection area 6m

Human activity and presence detection

Activity detection

HIGHER ACTIVITY After 20 mins absence

Cooling Set Temp. +/-0°C Cooling Set Temp. +2°CCooling Set Temp. +1°C Cooling Thermo OFF

Heating Set Temp. -1°C Heating Set Temp. -2°CHeating Set Temp. +/-0 °C Heating Thermo OFF

Each 2 min After 3 hours set up can be change to stop or temp shift

LOWER ACTIVITY After 3 hours absence

Presence detection

Test MethodTo establish conditions for our field tests, because human movements and door open/close are random, we did not test on set conditions. To replicate typical conditions, we have fixed variable numbers (see below) and tested how ECONAVI’s temperature control function contributes to energy efficiency level.For each temperature setting, we have tested and compared power consumption at three-hourly intervals.

Test Condition· Testing location: New 6,0HP testing room / 29m²· Test sample remote controller setting: Setting temperature:

Cooling 24 ~28°C / Fan Speed: Hi· Measured integral power consumption every 30 minutes and compare

(including thermo OFF period)· Room temperatures / 19°C, outdoor temperature 35/24°C (cooling

nominal capacity) cool down the room for 1 hour and keep the room temperature stable. After the room temperature become stable, turn OFF indoor unit refrigerator and heater and only operate circulator and continue cooling down the room by the unit (operating circulator to avoid temperature variation)

Model Evaluation (Laboratory Testing/Cooling Operation)

TEST SAMPLE TESTING LOCATION: BUILDING 1.460 NEW 6,0HP TESTING ROOM

Circulate air by CirculatorInstallation Board

Refrigerator piping

4-way Single Cassette 4,0HP S-100PT1E5

Indoor setting temperature 27/19°C. Turn OFF indoor unit refrigerator and heater and continue cooling operation (circulator operation ON).

PACi Elite Single 4,0HP U-100FE1E5

28%

ENERGY

SAVING

9.000

8.000

7.000

6.000

5.000

4.000

3.000

2.000

1.000

0 0 1 2 3

24°C 25°C 26°C 27°C 28°C

Remote controller setting temperature

Inte

gral

pow

er c

onsu

mpt

ion

(kW

h)

Operating time (hours)

INTEGRAL POWER CONSUMPTION COOLING OPERATION

Increasing setting temperature +2°C during cooling operation, maximum 28% Energy Saving can achieved.

Energy Saving for 28%

Energy Saving for 28%

Energy Saving for 28%

129

COMMERCIALNEW

360ºair flow

PACi Standard and Elite: indoor units360° Air Flow, 4 Way 90x90 Cassette PACi Standard and Elite

4 Way 90x90 Cassette. Wide & Comfortable Airfl owThis proprietary design provides a wide and very comfortable airflow. The cassette’s wide-angle discharge outlets and flaps are larger in the middle, featuring a shape that was selected based on geometrics and testing of actual prototype units. Air coming out of the center of the discharge outlets travels farther. From the sides of each outlet, where the openings are larger, airflow spreads out to reach the corners of the room. Air is discharged across a wide area from the four sides of the unit. The curves on the room temperature distribution graph expand gently out through 360° in a circle centered on the indoor unit.

NEW DC-FAN MOTOR.Optimum airflow is achieved by a new DC-fan motor with independent control.

INDIVIDUAL FLAP CONTROL.Flexible Air flow direction control by individual flap control is possible. 4 Flaps can be controlled individually by setting on wired timer remote controller. It can make more flexible Air-flow control to be matched to several demands in a room.

HIGHER EFFICIENCY SPLIT FIN.Improved heat-transfer coefficient due to adoption of high efficiently grooved heat exchanger tube.

HIGH-EFFICIENT & SILENT TURBO FAN.The newly developed larger fan chassis and optimised design of the airflow path has resulted in increased air volume and quieter performance.

360° Air Flow for improved comfort By redesigning the air-outlet and flap, Soft & 3D air flow circulates whole space and provides even temperature distribution in the room.

25.0 Temp.

Simulated condition: Floor area: 225 m². Ceiling height: 3 m, Unit 12.5 kW type.

More even temperature in the room.

CURRENT MODEL 360° AIR FLOW

1 m above the floor

360° AIR FLOW

IT’S HOTIT’S COLD

CURRENT MODEL

BETTER COMFORT

130

High-Ceiling Installation (Up to 5 m for 100 PU and higher models)The units can be installed in rooms with high ceilings, where they provide ample floor-level heating in the winter. (See ceiling height guidelines below.)

4-way discharge high ceiling settings²

3-way discharge with the optional air-blocking materials

2-way discharge with the optional air-blocking materials 5 m4,7 m4,5 m

Dirt collects on the ceiling

Airflow image from the new model

Airflow of conventional models

Dust PreventionWide direction air discharge by outlet design.The Circle Flow Flap and re-designed air-outlet eliminate airflow along recessed parts of the ceiling which reduces contamination. If air flows only along these recessed parts, they will quickly become dirty. The new, improved air outlet design therefore greatly reduces dirt accumulation.

Lighter and Slimmer, Easier InstallationA lightweight unit at 24 kg, the unit is also very slim with a height of only 256 mm, making installation possible even in narrow ceiling voids.

A Drain Height of Approx. 850 mm from the Ceiling SurfaceThe drain height can be increased by approximately 350 mm over the conventional value by using a high-lift drain pump, and long horizontal piping is possible.

Easy Maintenance and CleaningThe flap can be removed easily for washing with water.

Low-Profile 33,5 mm PanelThe square panel integrates seamlessly with the ceiling. Discharge outlets close when the unit is stopped.

A suction grill enables to make 90-degree turns.

High Ceiling (Factory settings)

3,0 m

Size 60 and 71

3,6 m

Size 100, 125 and 140

Ceiling height guidelines

Settings¹ 4 - way discharge 3 - way discharge (optionalair - blocking materials)

2 - way discharge (optionalair - blocking materials)²Factory settings¹ High ceiling setting¹ High ceiling setting²

Indoor unit: 60PU-71PU 3,0 3,3 3,6 3,8 4,2Indoor unit: 100PU, 125PU, 140PU 3,6 3,9 4,5 4,7 5,0

1) When using the unit in a configuration other than the factory settings, it is necessary to make settings on site to increase airflow. 2) Use air-blocking materials (CZ-CFU2) to completely block two discharge outlets for 2-way airflow.

Drain Pump of about 850 mm from the ceiling surface

Up to 300 mm

Up to 850 mm

Only 256 mm*

* For 6,0kW / 7,1kW

Flexible 3D air-flow controlComfort air flow control & proper energy use. Flexible Air flow direction control by individual flap control:· 4 Flaps can be controlled

individually (by standard wired remote controller*).

· Versatile air flow control to cover a wide variety of demands.

* Pre-setting is required for this function at System Test-run procedure.

Outlet C:Swing

Outlet D:Fixed to Lower

Outlet B: Fix to upper

Outlet A:Swing (only upper)

INDUSTRY’STOP-CLASS

Ample airflow: 36 m3/minIndustry’s highest in the 140 PU class.

Protrusion of 33,5 mm

ONE OF THE INDUSTRY’S THINNEST PANELS

131

COMMERCIAL PACi ELITE / STANDARD

PACi Standard and Elite: indoor units

New 4-Way 60x60 Cassette

Lighter and slimmer, easier installationLightweight and very slim which makes installation possible even in narrow ceilings.A drain height of approx. 850 mm from the ceiling surfaceThe drain height can be increased by approx. 350 mm over the conventional value by using a high-lift drain pump, and long horizontal piping is possible.Significant reduction of power consumption by using highly developed DC fan motors with variable speed, special heat exchangers, etc.Convenient cleaning. The flap can be removed easily for washing.

Wall Mounted

The unit’s compact design and flat face ensure discreet installation, even in a small space.

Washable front panel.The indoor unit’s front panel can be easily removed and washed for trouble-free cleaning.

Closed discharge portWhen the unit is turned OFF, the flap closes completely to prevent dust getting into the unit and to keep the equipment clean.

Quiet operationThese units are among the quietest in the industry, making them ideal for hotels and hospitals.

Smooth and durable designThe sleek, compact design ensures a discreet installation - even where space is limited.

Piping outlet in three directionsWith three options for pipe outlets-rear, right and left - installation is made easy.

Air distribution is altered dependingon the operational mode of the unit

F2

F3

F4F5

90º

F1

Heating: F1 to F5Cooling: F1 to F3

132

High Static Pressure Hide Away (PF Type)

Discharge air temperature control· Possible to reduce cold drafts at heating operation.

Cold Drafts Reduction at Heating· Accurate temperature

measurement by E2 sensor to reduce cold drafts at heating.

Before spec-in, please consult with an authorized Panasonic dealer.

System ExampleAn inspection port (450 mm x 450 mm or more) is required at the control-box side of the indoor unit body.

Air intake sensor

E2 sensor

Rectangle duct

Inspection port (450 x 450 mm or more)

Canvas duct

Intake grille

Ceiling

Further comfort improvementThe wide air discharge opening expands the air flow to the left and the right. The unpleasant feeling caused when the air flow directly hits the human body is prevented by the “Draft prevention position”, which changes the swing width, so that the degree of comfort is increased.

60º

F1

F2

F3

F4

F5

Heating: F1 to F5Cooling: F1 to F3

4m

7m

Low Static Pressure Hide Away (PN Type)

Ultra-slim profile: 250 mm height for all models.

250 mm

Air distribution is altered depending on the operational mode of the unit

Further comfort improvement with airflow distribution

The static pressure outside the unit can be increased up to 150 Pa.Type 60 71 100 125 140Standard 70 Pa 70 Pa 100 Pa 100 Pa 100 PaMaximum available setting 150 Pa 150 Pa 150 Pa 150 Pa 150 Pa

More powerful drain pumpUsing a high-lift drain pump, drain piping can be elevated up to 785 mm from the base of the unit.

Air inletThe unit features air inlet on one side, air outlet on the other side. The air inlet filter can be pulled out from the side of the unit and can be folded. Easy access if through the maintenance opening.

When air inlet duct (field supplied) is connected on suction side, remove the filter, frame and insulation materials on both sides of the unit. Connect the duct on the suction side of the unit by using prepared holes on the unit.

Air outlet siteA rectangular duct flange for the air outlet is fitted as standard. Round outlet flange kits are available as an optional accessory kit.

Circle duct flange (option)Number of exits with diameters Model Code2 x Ø 200 CZ-56DAF2 (2 SA outlet)3 x Ø 200 CZ-90DAF2 (3 SA outlet)4 x Ø 200 CZ-160DAF2 (4 SA outlet)

Standard

Round flange : CZ-160DAF2 w200 outlet frange x 4 ports

Built-in Drain pump (DC motor pump)

- Built-in filter- Side removable filter

Standardized height of 290 mm for all modelsHeight standardization enables easy and uniform installation for models with different capacities.

External electrical equipment box makes maintenance easyP-link PCB

133

COMMERCIAL PACi ELITE / STANDARD

Range of Commercial units

Indoor Units PACi Standard And Elite 3.6 kW 4.5 kW 5.0 kW 6.0 kWWall PACi Inverter+

S-36PK1E5A S-45PK1E5A S-50PK1E5A S-60PK1E5A

4 - Way 60x60 Cassette PACi Inverter+(for Twin combinations)

S-36PY2E5A S-45PY2E5A S-50PY2E5A

4 Way 90x90 CassettePACi Inverter+

S-36PU1E5A S-45PU1E5A S-50PU1E5A S-60PU1E5A

Low Static Pressure Hide AwayPACi Inverter+

S-36PN1E5A S-45PN1E5A S-50PN1E5A S-60PN1E5A

High Static Pressure Hide AwayPACi Inverter+

S-36PF1E5A S-45PF1E5A S-50PF1E5A S-60PF1E5A

CeilingPACi Inverter+

S-36PT2E5A S-45PT2E5A S-50PT2E5A S-60PT2E5A

High Static Pressure Hide Away20,0 - 25,0 kW PACi Inverter+

AHU Kit

PAW-280PAH2 PAW-280PAH2

Air Curtain with DX Coil Jet-Flow

Air Curtain with DX Coil Standard

1) Available from November 2014. * The indoor units from 3,6 to 5,0 kW are only available only for Twin, Triple and Doble-Twin combinations.

Wall Mounted for professional applications 2.8 kW 3.2 kW 4.5 kW 5.0 kWWall Mounted PKEA*

CS-E9PKEA CS-E12PKEA CS-E15PKEA CS-E18PKEA

* PKEA indoor units are only compatible with PKEA Outdoor Units.

OUTDOOR UNITS PACi STANDARD AND ELITE 5.0 kW 6.0 kWPACi STANDARD

U-60PEY1E5 I

PACi ELITE

U-50PE1E5 I U-60PE1E5A I

I Single Phase III Three Phase

NEW

NEW

NEW

NEW

NEW

NEW

NEW

NEW

134

7.1 kW 10.0 kW 12.5 kW 14.0 kW 20.0 kW 25.0 kW

S-71PK1E5A S-100PK1E5A

S-71PU1E5A S-100PU1E5A S-125PU1E5A S-140PU1E5A

S-71PN1E5A S-100PN1E5A S-125PN1E5A S-140PN1E5A

S-71PF1E5A S-100PF1E5A S-125PF1E5A S-140PF1E5A

S-71PT2E5A S-100PT2E5A S-125PT2E5A S-140PT2E5A

S-200PE1E8AS-200PE2E5¹

S-250PE1E8S-250PE2E5¹

PAW-280PAH2 PAW-280PAH2 PAW-280PAH2 PAW-280PAH2 PAW-280PAH2 PAW-280PAH2

PAW-10PAIRC - MJ PAW-15PAIRC - MJ PAW-20PAIRC - MJ

PAW-10PAIRC - MS PAW-20PAIRC - MS

7.1 kW 10.0 kW 12.5 kW 14.0 kW 20.0 kW 25.0 kW

U-71PEY1E5 I U-100PEY1E5 I // U-100PEY1E8 III U-125PEY1E5 I // U-125PEY1E8 III U-140PEY1E8 III

U-71PE1E5A I // U-71PE1E8A III U-100PE1E5A I // U-100PE1E8A III U-125PE1E5A I // U-125PE1E8A III U-140PE1E5A I // U-140PE1E8A III U-200PE1E8 III U-250PE1E8 III

135

COMMERCIAL PACi ELITE / STANDARDNEW

Possibleto use on

R22 pipings

R22 RENEWAL

InternetControlReady

INTERNET CONTROL

OPTIONAL

7.10 A++SEER

SEASONAL ENERGY EFFICIENCY RATIO

4.40 A+SCOP

SEASONAL COEFFICIENT OF PERFORMANCE

Down to

-15°C incooling mode

OUTDOORTEMPERATURE

Down to

-15°C inheating mode

OUTDOORTEMPERATURE

5 yearcompressorwarranty

Energy saving

Easycontrolby BMS

CONNECTIVITY

Complete line-up with high efficiency even at -15°CThis Wall Mounted air conditioner is especially designed for professional applications such as computer rooms where cooling inside the room is necessary even when the outside temperature is low. Furthermore this air conditioner has an automatic changeover system, in order to maintain the inside temperature even when sharp outside temperature changes occur.

WALL MOUNTED PKEA

ESEER and SCOP: For KIT-E9-PKEA. 5 YEARS COMPRESSOR WARRANTY: Only for PRO partners.

Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)Rating Conditions for cooling capacity at low temperature: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 0°C DB / -10°C WB.

1) The annual energy consumption is calculated in accordance with the ErP directive. 2) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 1.5 m from the ground The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 3) Add 70 mm for piping port. 4) When installing the outdoor unit at a higher position than the indoor unit.Recommended fuse for the indoor 3A.Specifications subject to change without notice.For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu

Single Phase2.8 kW 3.2 kW 4.5 kW 5.0 kW

KIT KIT-E9-PKEA KIT-E12-PKEA KIT-E15-PKEA KIT-E18-PKEAIndoor CS-E9PKEA CS-E12PKEA CS-E15PKEA CS-E18PKEAOutdoor CU-E9PKEA CU-E12PKEA CU-E15PKEA CU-E18PKEACooling capacity Nominal (Min-Max) kW 2.50 (0.85-3.00) 3.50 (0.85-4.00) 4.20 (0.98-5.00) 5.00 (0.98-6.00)

Nominal (Min-Max) kCal/h 2,150 (730-2,580) 3,010 (730-3,440) 3,610 (840-4,300) 4,300 (840-5,160)Cooling capacity at -10°C Nominal kW 2.63 3.69 5.04 6.00EER at -10°C Nominal Energy Saving 7.19 5.96 6.01 6.00Cooling capacity at -20°C Nominal kW 2.61 3.66 4.06 5.82EER at -20°C Nominal Energy Saving 6.71 5.56 4.39 5.39ESEER Nominal Energy Saving 7.1 i 6.7 i 6.3 i 6.9 iPdesign kW 2.5 3.5 4.2 5.0Power input Cooling Nominal (Min-Max) kW 0.515 (0.170-0.710) 0.870 (0.170-1.120) 1.200 (0.280-1.580) 1.440 (0.280-1.990)Annual electricity consumption (cooling) 1) kWh/a 123 183 233 254Heating capacity Nominal (Min-Max) kW 3.40 (0.85-5.40) 4.00 (0.85-6.60) 5.40 (0.98-7.10) 5.80 (0.98-8.00)

Nominal (Min-Max) kCal/h 2,920 (730-4,640) 3,440 (730-5,680) 4,640 (840-6,110) 4,990 (840-6,880)Heating capacity at -7°C Nominal kW 3.33 4.07 4.10 4.98SCOP Nominal Energy Saving 4.4 h 4.1 h 3.9 a 4.2 hPdesign at -10 °C kW 2.8 3.6 3.6 4.4Power input Heating Nominal (Min-Max) kW 0.700 (0.165-1.310) 0.920 (0.165-1.820) 1.440 (0.340-2.190) 1.520 (0.340-2.570)Annual electricity consumption (heating) 1) kWh/a 891 1,229 1,292 1,467Indoor UnitPower source V 230 230 230 230Recommended Fuse A 16 16 16 16Connection indoor / outdoor mm 4 x 1.5 4 x 1.5 4 x 1.5 4 x 2.5Current (Nominal) Cooling / Heating A 2.5 / 3.3 4.0 / 4.2 5.4 / 6.5 6.4 / 6.8Max. Current A 7.8 8.4 9.6 11.3Air Volume Cooling / Heating m³/h 798 / 876 816 / 882 846 / 900 1,074 / 1,158Moisture removal volume l/h 1.5 2.0 2.4 2.8Sound pressure level 2) Cooling (Hi / Lo / S-Lo) dB(A) 39 / 26 / 23 42 / 29 / 26 43 / 32 / 29 44 / 37 / 34

Heating (Hi / Lo / S-Lo) dB(A) 40 / 27 / 24 42 / 33 / 29 43 / 35 / 29 44 / 37 / 34Sound power level Cooling / Heating (Hi) dB 55 / 56 58 / 58 59 / 59 60 / 60Dimensions H x W x D mm 295 x 870 x 255 295 x 870 x 255 295 x 870 x 255 295 x 1,070 x 255Net weight kg 10 10 10 13Air purifier filterOutdoor UnitAir Volume Cooling / Heating m³/h 1,878 / 1,782 1,974 / 1,926 2,052 / 1,980 2,352 / 2,274Sound pressure level 2) Cooling / Heating (Hi) dB(A) 46 / 47 48 / 50 46 / 46 47 / 47Sound power level Cooling / Heating (Hi) dB 61 / 62 63 / 65 61 / 61 61 / 61Dimensions 3) H x W x D mm 622 x 824 x 299 622 x 824 x 299 695 x 875 x 320 695 x 875 x 320Net weight kg 36 36 45 46Piping connections Liquid pipe / Gas pipe inch (mm) 1/4" (6.35) / 3/8" (9.52) 1/4" (6.35) / 3/8" (9.52) 1/4" (6.35) / 1/2" (12.70) 1/4" (6.35) / 1/2" (12.70)Refrigerant loading R410A kg 1,100 1,100 1.060 1.240Elevation difference (in/out) 4) Max m 5 5 15 15Piping length Min / Max m 3-15 3-15 3-15 3-20Precharge length Max m 7.5 7.5 7.5 7.5Additional charge g/m 20 20 20 20Operating range Cooling Min / Max °C -20 / +43 -20 / +43 -20 / +43 -20 / +43

Heating Min / Max °C -15 / +24 -15 / +24 -15 / +24 -15 / +24

· SERVER ROOM

SOLUTION WITH THE

HIGHEST EFFICIENCY OF

THE MARKET

· 24/7 OPERATION

136

Outdoor· Cooling even when ambient temperature is as low as -15°C· Electronic expansion valve (accurate sub-cooling and adjustable

refrigerant flow)· Outdoor DC fan motor to provide flexible air-flow to ensure optimum

condensation pressure (works on outdoor pipe temperature sensor)

Interface option to manage server room operationThe PAW-SERVER-PKEA server room interface manages redundancy and backup of two PKEA units with two different selectable modes:· Plug and play by embedded redundancy and backup algorithm (no

external signal needed. Further details please refer to operation manual) · External (third party PLC) redundancy and backup management by dry

contactAll settings are possible without the need for a computer connection.A special Energy Saving Mode is selectable by deep switch (available only in plug and play mode).The level of remote control input prohibition can be set when external management is by dry contact.

Optional accessory: PAW-SERVER-PKEA

Dry contacts

Included on the kitTimer remote controller

KIT-E9-PKEA // KIT-E12-PKEA // KIT-E15-PKEA // KIT-E18-PKEA

Technical Focus

· New! This units can be installed on R22 pipings· Designed for 24h/7d a week operation· Highly efficient even at -15°C· High durability rolling bearings · Additional piping sensors to prevent freezing

CU-E9PKEACU-E12PKEA

CU-E15PKEACU-E18PKEA

137

COMMERCIAL

STANDARD

STANDARD

WALL MOUNTEDPACi STANDARD AND ELITE INVERTER+

New Wall Mounted PACi. The extension of the range to include a 10 kW unit allows for many more applications such as studios, gyms, high ceiling areas and even computer server rooms.

Technical Focus

· New! 10.0 kW capacity unit· Flat face design for modern appearance· Compact design offers over 15% reduction in overall size· Washable front panel· DC FAN for better efficiency and control· Three directional piping outlet· Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB.

The external device can be control by the remote control of the Panasonic indoor unit

5.40 ASEER

SEASONAL ENERGY EFFICIENCY RATIO

Down to

-10°C incooling mode

OUTDOORTEMPERATURE

3.90 ASCOP

SEASONAL COEFFICIENT OF PERFORMANCE

Down to

-15°C inheating mode

OUTDOORTEMPERATURE

Possibleto use on

R22 pipings

R22 RENEWAL

5 yearcompressorwarranty

Easycontrolby BMS

CONNECTIVITY

INTERNET CONTROL READY: Optional. ESEER and SCOP: For KIT-60PKY1E5A. 5 YEARS COMPRESSOR WARRANTY: Only for PRO partners.

Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.1) The annual consumption(ErP) is calculated by formula determined by ErP regulation. 2) Heating capacity is calculated including defrost factor correction. 3) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 1.5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 4) When installing the outdoor unit at a higher position than the indoor unit. // Recommended fuse for the indoor 3A. // * Available from June 2014.For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu

Energy saving

U-60PEY1E5 U-71PEY1E5

Single Phase Three Phase6.0 kW 7.1 kW 10.0 kW 10.0 kW

KIT KIT-60PKY1E5A* KIT-71PKY1E5A* KIT-100PKY1E5A* KIT-100PKY1E8A*Indoor S-60PK1E5A S-71PK1E5A S-100PK1E5A S-100PK1E5AOutdoor U-60PEY1E5 U-71PEY1E5 U-100PEY1E5 U-100PEY1E8Timer remote controller CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2Cooling capacity Nominal (Min - Max) kW 6.0 (2.0 - 7.0) 7.1 (2.0 - 7.7) 9.0 (2.7 - 9.7) 9.0 (2.7 - 9.7)ESEER W/W 5.4 a 5.1 a 5.8 h 5.7 hPdesign kW 6.0 7.1 9.0 9.0Power input cooling Nominal (Min - Max) kW 1.860 (0.325 - 2.750) 2.450 (0.325 - 3.000) 3.370 (0.530 - 3.800) 3.370 (0.530 - 3.800)Annual energy consumption (ErP) 1) kWh/a 389 487 543 553Heating capacity Nominal (Min - Max) kW 6.0 (1.8 - 7.0) 7.1 (1.8 - 8.1) 9.0 (2.1 - 10.5) 9.0 (2.1 - 10.5)Heating capacity at -7°C 2) Nominal kW 4.39 4.32 7.22 7.22SCOP W/W 3.9 a 3.9 a 3.8 a 3.8 aPdesign at -10°C kW 6.0 6.0 9.0 9.0Power input heating Nominal (Min - Max) kW 1.500 (0.275 - 2.200) 1.900 (0.275 - 2.550) 2.430 (0.410 - 3.000) 2.430 (0.410 - 3.000)Annual energy consumption (ErP) 1) kWh/a 2154 2154 3,316 3,316Indoor unitAir volume Cooling (Hi / Med / Lo) m³/h 1,080 / 870 / 690 1,080 / 870 / 690 1,140 / 990 / 780 1,140 / 990 / 780

Heating (Hi / Med / Lo) m³/h 1,080 / 870 / 690 1,080 / 870 / 690 1,140 / 990 / 780 1,140 / 990 / 780Moisture removal volume l/h 3.4 4.2 5.4 5.4Sound pressure level 3) Cooling (Hi / Med / Lo) dB(A) 47 / 44 / 40 47 / 44 / 40 49 / 45 / 41 49 / 45 / 41

Heating (Hi / Med / Lo) dB(A) 47 / 44 / 40 47 / 44 / 40 49 / 45 / 41 49 / 45 / 41Sound power level Cooling (Hi) dB 64 64 66 66

Heating (Hi) dB 64 64 66 66Dimensions H x W x D mm 300 x 1,065 x 230 300 x 1,065 x 230 300 x 1,065 x 230 300 x 1,065 x 230Net weight kg 14.5 14.5 14,5 14,5Outdoor unitPower source V 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 380 / 400 / 415Recommended fuse A 20 20 25 16Connection mm² 2.5 2.5 4.0 2.5Current Cooling A 8.80 / 8.50 / 8.25 11.7 / 11.3 / 10.9 16.0 / 15.3 / 14.6 5.40 / 5.15 / 4.95

Heating A 7.05 / 6.80 / 6.60 9.00 / 8.70 / 8.40 11.2 / 10.8 / 10.4 3.85 / 3.65 / 3.55Air volume Cooling / Heating m³/h 1,800 / 2,100 2,340 / 2,340 4,560 / 4,020 4,560 / 4,020Sound pressure level Cooling / Heating (Hi) dB(A) 46 / 50 50 / 52 54 / 54 54 / 54Sound power level Cooling / Heating (Hi) dB 65 / 69 70 / 70 70 / 70 70 / 70Dimensions H x W x D mm 569 x 790 x 285 569 x 790 x 285 996 x 940 x 340 996 x 940 x 340Net weight kg 42 42 73 73Piping connections Liquid pipe Inch (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)

Gas pipe Inch (mm) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)Refrigerant loading R410A kg 1.7 1.7 2.60 2.60Elevation difference (in/out) 4) Max m 30 30 30 30Piping length Min / Max m 5 / 50 5 / 50 5 / 50 5 / 50Precharge length Max m 20 20 30 30Additional charge g/m 40 40 50 50Operating range Cooling Min / Max °C -10 / +43 -10 / +43 -10 / +43 -10 / +43

Heating Min / Max °C -15 / +24 -15 / +24 -15 / +24 -15 / +24

InternetControlReady

INTERNET CONTROL

OPTIONAL

NEW

U-100PEY1E5 U-100PEY1E8

138

ELITE

ELITE

Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.1) The annual consumption(ErP) is calculated by formula determined by ErP regulation. 2) Heating capacity is calculated including defrost factor correction. 3) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 1.5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 4) When installing the outdoor unit at a higher position than the indoor unit. // Recommended fuse for the indoor 3A. // * Available from June 2014. ** Available from July 2014.For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu

Down to

-15°C incooling mode

OUTDOORTEMPERATURE

Down to

-20°C inheating mode

OUTDOORTEMPERATURE

Easycontrolby BMS

CONNECTIVITY

Energy saving

Possibleto use on

R22 pipings

R22 RENEWAL

5 yearcompressorwarranty

6.60 A++SEER

SEASONAL ENERGY EFFICIENCY RATIO

3.90 ASCOP

SEASONAL COEFFICIENT OF PERFORMANCE

INTERNET CONTROL READY: Optional. ESEER and SCOP: For KIT-60PK1E5A and KIT-71PK1E5A. 5 YEARS COMPRESSOR WARRANTY: Only for PRO partners.

U-60PE1E5A U-71PE1E5A U-100PE1E5A

U-71PE1E8AU-100PE1E8A

U-50PE1E5

Single Phase Three Phase5.0 kW 6.0 kW 7.1 kW 10.0 kW 7.1 kW 10.0 kW

KIT KIT-50PK1E5A* KIT-60PK1E5A* KIT-71PK1E5A* KIT-100PK1E5A** KIT-71PK1E8A* KIT-100PK1E8A**Indoor S-50PK1E5A S-60PK1E5A S-71PK1E5A S-100PK1E5A S-71PK1E5A S-100PK1E5AOutdoor U-50PE1E5 U-60PE1E5A U-71PE1E5A U-100PE1E5A U-71PE1E8A U-100PE1E8ATimer remote controller CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2Cooling capacity Nominal (Min - Max) kW 5.0 (1.5 - 5.6) 6.0 (2.5 - 7.1) 7.1 (2.5 - 8.0) 9.5 (3.3 - 10.5) 7.1 (3.2 - 8.0) 9.5 (3.3 - 10.5)ESEER W/W 6.0 h 6.6 i 6.6 i 6.2 i 6.1 i 6.0 hPdesign kW 5.0 6.0 7.1 9.5 7.1 9.5Power input cooling Nominal (Min - Max) kW 1.560 (0.260 - 2.250) 1.560 (0.450 - 2.000) 2.090 (0.450 - 2.650) 2.920 (0.840 - 3.400) 2.090 (0.560 - 2.650) 2.920 (0.840 - 3.400)Annual energy consumption (ErP) 1) kWh/a 292 318 376 536 407 554Heating capacity Nominal (Min - Max) kW 5.6 (1.5 - 6.5) 7.0 (2.0 - 8.0) 8.0 (2.0 - 9.0) 9.5 (4.1 - 11.5) 8.0 (2.8 - 9.0) 9.5 (4.1 - 11.5)Heating capacity at -7°C 2) Nominal kW 3.62 5.85 6.69 9.63 6.69 9.63Heating capacity at -15°C 2) Nominal kW 3.08 5.74 6.80 9.05 6.80 9.05SCOP W/W 3.9 a 3.9 a 3.9 a 3.8 a 3.8 a 3.8 aPdesign at -10°C kW 4.0 6.0 7.1 9.5 7.1 9.5Power input heating Nominal (Min - Max) kW 1.500 (0.220 - 2.450) 1.820 (0.400 - 2.480) 2.130 (0.400 - 2.900) 2.470 (0.900 - 3.350) 2,130 (0,500-2,900) 2.470 (0.900 - 3.350)Annual energy consumption (ErP) 1) kWh/a 1,436 2,154 2,548 3,500 2,616 3,500Indoor unitAir volume Cooling (Hi / Med / Lo) m³/h 840 / 720 / 630 1,080 / 870 / 690 1,080 / 870 / 690 1,140 / 990 / 780 1,080 / 870 / 690 1,140 / 990 / 780

Heating (Hi / Med / Lo) m³/h 840 / 720 / 630 1,080 / 870 / 690 1,080 / 870 / 690 1,140 / 990 / 780 1,080 / 870 / 690 1,140 / 990 / 780Moisture removal volume l/h 2.8 3.4 4.2 5,7 4.2 5,7Sound pressure level 3) Cooling (Hi / Med / Lo) dB(A) 40 / 36 / 32 47 / 44 / 40 47 / 44 / 40 49/45/41 47 / 44 / 40 49/45/41

Heating (Hi / Med / Lo) dB(A) 40 / 36 / 32 47 / 44 / 40 47 / 44 / 40 49/45/41 47 / 44 / 40 49/45/41Sound power level Cooling (Hi) dB 57 64 64 66 64 66

Heating (Hi) dB 57 64 64 66 64 66Dimensions H x W x D mm 300 x 1,065 x 230 300 x 1,065 x 230 300 x 1,065 x 230 300 x 1065 x 230 300 x 1,065 x 230 300 x 1065 x 230Net weight kg 13.0 14.5 14.5 14,5 14.5 14,5Outdoor unitPower source V 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 380 / 400 / 415 380 / 400 / 415Recommended fuse A 16 20 20 25 16 16Connection mm² 2.5 2.5 2.5 4 2.5 2.5Current Cooling A 7.25 / 7.00 / 6.80 7.45 / 7.15 / 6.95 9.75 / 9.40 / 9.10 13.4 / 12.9 / 12.4 3.25 / 3.15 / 3.05 4.60 / 4.40 / 4.30

Heating A 6.95 / 6.75 / 6.50 8.45 / 8.15 / 7.90 9.85 / 9.50 / 9.20 11.3 / 10.9 / 10.6 3.30 / 3.20 / 3.10 3.85 / 3.70 / 3.60Air volume Cooling / Heating m³/h 1,800 / 2,100 3,600 / 3,600 3,600 / 3,600 6,600 / 5,700 3,600 / 3,600 6,600 / 5,700Sound pressure level Cooling / Heating (Hi) dB(A) 46 / 50 48 / 50 48 / 50 52 / 52 48 / 50 52 / 52Sound power level Cooling / Heating (Hi) dB 65 / 69 65 / 67 65 / 67 69 / 69 65 / 67 69 / 69Dimensions H x W x D mm 569 x 790 x 285 996 x 940 x 340 996 x 940 x 340 1,416 x 940 x 340 996 x 940 x 340 1,416 x 940 x 340Net weight kg 42 68 69 98 71 98Piping connections Liquid pipe Inch (mm) 1/4 (6.35) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)

Gas pipe Inch (mm) 1/2 (12.7) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)Refrigerant loading R410A kg 1.65 2 2.35 3.4 2.35 3.4Elevation difference (in/out) 4) Max m 30 30 30 30 30 30Piping length Min / Max m 5 / 40 5 / 50 5 / 50 5 / 75 5 / 50 5 / 75Precharge length Max m 30 30 30 30 30 30Additional charge g/m 20 50 50 50 50 50Operating range Cooling Min / Max °C -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46

Heating Min / Max °C -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24

InternetControlReady

INTERNET CONTROL

OPTIONAL

Compatible with all Panasonic connectivity solutions. For detailed information go to the VRF Control Systems section.

Optional ControllerTimer remote controllerCZ-RTC2

Optional ControllerWired remote controllerCZ-RTC3

Optional Controller Wireless remote controllerCZ-RWSK2

Optional Controller Simplified remote controllerCZ-RE2C2

NEW NEW

HIGH

HEATING

CAPACITY

AT -7°C

139

COMMERCIAL PACi ELITE / STANDARDNEW

STANDARD

STANDARD

3.6 kW 4.5 kW 5.0 kWIndoor S-36PY2E5A1)* S-45PY2E5A1)* S-50PY2E5A*Panel CZ-KPY3A CZ-KPY3A CZ-KPY3ACooling capacity Nominal kW 3.6 4.5 5.0Heating capacity Nominal kW 4.2 5.2 5.6Air volume Cool/Heat m³/h 540 / 540 636 / 636 750 / 750Moisture removal volume l/h 2.1 2.5 2.8Sound pressure level 2) Cooling (Hi / Med / Lo) dB(A) 32 / 29 / 26 36 / 32 / 28 41 / 37 / 33

Heating (Hi / Med / Lo) dB(A) 32 / 29 / 26 36 / 32 / 28 41 / 37 / 33Sound power level Cooling (Hi) dB 49 / 46 / 42 53 / 48 / 45 58 / 54 / 50

Heating (Hi) dB 49 / 46 / 42 53 / 48 / 45 58 / 54 / 50Dimensions (H x W x D) Indoor mm 283 x 575 x 575 283 x 575 x 575 283 x 575 x 575

Panel mm 30 x 625 x 625 30 x 625 x 625 30 x 625 x 625Net weight Indoor (Panel) kg 16 (2.4) 16 (2.4) 16 (2.4)

Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.

1) Only for multi combinations.Recommended fuse for the indoor 3A.* Available from November 2014.

4 WAY 60x60 CASSETTEPACi STANDARD AND ELITE INVERTER+

Small and powerful, ideal for offices and restaurants. Only for Twin, Triple and Double-twin combinations.

Technical Focus

· Fresh air knock out· Multidirectional air flow· Integrated drain pump gives 850 mm lift· 3 speed centrifugal fan· DC FAN for better efficiency and control· Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB.

The external device can be control by the remote control of the Panasonic indoor unit

140

ELITE

ELITE

PanelCZ-KPY3A

5.0 kWKIT KIT-50PY2E5A*Indoor S-50PY2E5AOutdoor U-50PE1E5Panel CZ-KPY3ATimer remote controller CZ-RTC2Cooling capacity Nominal (Min - Max) kW 5.0 (1.5 - 5.6)ESEER W/W 5.90 hPdesign kW 5.0Power input cooling Nominal (Min - Max) kW 1.64 (0.260 - 2.45)Annual energy consumption (ErP) 1) kWh/a 297Heating capacity Nominal (Min - Max) kW 5.6 (1.5 - 6.3)Heating capacity at -7°C 2) Nominal kW 3.62Heating capacity at -15°C 2) Nominal kW 3.08SCOP W/W 3.80 aPdesign at -10°C kW 4.0Power input heating Nominal (Min - Max) kW 1.79 (0.22 - 2.57)Annual energy consumption (ErP) 1) kWh/a 1,474Indoor unitAir volume Cooling / Heating m³/h 750 / 750Moisture removal volume l/h 2.8Sound pressure level 3) Cooling (Hi / Me / Lo) dB(A) 41 / 37 / 33

Heating (Hi / Me / Lo) dB(A) 41 / 37 / 33Sound power level Cooling (Hi) dB 58 / 54 / 50

Heating (Hi) dB 58 / 54 / 50Dimensions (H x W x D) Indoor mm 283 x 575 x 575

Panel mm 30 x 625 x 625Net weight kg 16Outdoor unitPower source V 220 - 240Recommended fuse A 16Connection mm² 2.5Current Cooling A 7.5

Heating A 8.2Air volume Cooling / Heating m³/h 1,800 / 2,100Sound pressure level Cooling / Heating (Hi) dB(A) 46 / 50Sound power level Cooling / Heating (Hi) dB 65 / 69Dimensions H x W x D mm 569 x 790 x 285Net weight kg 42Piping connections Liquid pipe Inch (mm) 1/4 (6.35)

Gas pipe Inch (mm) 1/2 (12.7)Refrigerant Loading R410A kg 1.65Elevation difference (in/out) 4) Max m 30Piping length Min / Max m 5 ~ 40Precharge length Max m 30Additional gas g/m 20Operating range Cooling Min / Max °C -15 / +46

Heating Min / Max °C -20 / +24

Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.1) The annual consumption(ErP) is calculated by formula determined by ErP regulation. 2) Heating capacity is calculated including defrost factor correction. 3) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 1.5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 3) When installing the outdoor unit at a higher position than the indoor unit. Recommended fuse for the indoor 3A. * Available from November 2014.For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu

Energy saving

5.90 A+SEER

SEASONAL ENERGY EFFICIENCY RATIO

3.80 ASCOP

SEASONAL COEFFICIENT OF PERFORMANCE

Down to

-15°C incooling mode

OUTDOORTEMPERATURE

Down to

-20°C inheating mode

OUTDOORTEMPERATURE

Easycontrolby BMS

CONNECTIVITY

Possibleto use on

R22 pipings

R22 RENEWAL

5 yearcompressorwarranty

U-50PE1E5

InternetControlReady

INTERNET CONTROL

OPTIONAL

INTERNET CONTROL READY: Optional. 5 YEARS COMPRESSOR WARRANTY: Only for PRO partners.

Compatible with all Panasonic connectivity solutions. For detailed information go to the VRF Control Systems section.

Optional ControllerTimer remote controllerCZ-RTC2

Optional ControllerWired remote controllerCZ-RTC3

Optional Controller Wireless remote controllerCZ-RWSK2

Optional Controller Simplified remote controllerCZ-RE2C2

HIGH

HEATING

CAPACITY

AT -7°C

141

COMMERCIAL PACi ELITE / STANDARDNEW

STANDARD

STANDARD

Energy saving

Down to

-10°C incooling mode

OUTDOORTEMPERATURE

Down to

-15°C inheating mode

OUTDOORTEMPERATURE

Easycontrolby BMS

CONNECTIVITY

Single Phase Three Phase6.0 kW 7.1 kW 10.0 kW 12.5 kW 10.0 kW 12.5 kW 14.0 kW

KIT KIT-60PUY1E5A* KIT-71PUY1E5A* KIT-100PUY1E5A* KIT-125PUY1E5A* KIT-100PUY1E8A* KIT-125PUY1E8A* KIT-140PUY1E8A*Indoor S-60PU1E5A S-71PU1E5A S-100PU1E5A S-125PU1E5A S-100PU1E5A S-125PU1E5A S-140PU1E5AOutdoor U-60PEY1E5 U-71PEY1E5 U-100PEY1E5 U-125PEY1E5 U-100PEY1E8 U-125PEY1E8 U-140PEY1E8Panel CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21Timer remote controller CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2Cooling capacity Nominal (Min - Max) kW 6.0 (2.0 - 7.0) 7.1 (2.0 - 7.7) 10.0 12.5 (3.8 - 13.5) 10.0 (2.7 - 11.5) 12.5 (3.8 - 13.5) 14.0 (3.3 - 15.5)ESEER Nominal (Min - Max) W/W 6.8 i 6.3 i 6.4 i 3.66 1) 6.2 i 3.66 1) 3.80 1)

Pdesign kW 6.0 7.1 10 — 10.0 — —Power input cooling Nominal (Min - Max) kW 1.690 (0.325 - 2.500) 2.190 (0.325 - 2.800) 3.220 (0.530 - 4.200) 4.020 (0.900 - 5.000) 3.220 (0.530 - 4.200) 4.020 (0.900 - 5.000) 4.36 (0.84 - 6.00)Annual energy consumption (ErP) 2) kWh/a 309 394 547 — 564 — —Heating capacity Nominal (Min - Max) kW 6.0 (1.8 - 7.0) 7.1 (1.8 - 8.1) 10.0 12.5 (3.4 - 15.0) 10.0 (2.1 - 13.8) 12.5 (3.4 - 15.0) 14.0 (4.1 - 16.0)Heating capacity at -7°C 3) Nominal kW 4.39 4.32 7.22 9.14 7.22 9.14 11.68Heating capacity at -15°C 3) Nominal kW — — — — — — —SCOP Nominal (Min - Max) W/W 4.0 h 4.0 h 4.0 h 3.40 4) 4.0 h 3.40 4) 3.52 4)

Pdesign at -10°C kW 6.0 6.0 10.0 — 10.0 — —Power input heating Nominal (Min - Max) kW 1.480 (0.275 - 2.155) 1.880 (0.275 - 2.510) 2.630 (0.410 - 4.000) 3.290 (0.730 - 4.400) 2.630 (0.410 - 4.000) 3.290 (0.730 - 4.400) 3.60 (0.90 - 5.20)Annual energy consumption (ErP) 2) kWh/a 2,100 2,100 3,500 — 3,500 — —Indoor unitAir volume Cooling (Hi / Med / Lo) m³/h 1,260 / 1,020 / 840 1,320 / 1,020 / 840 1,980 / 1,620 / 1,260 2,100 / 1,680 / 1,320 1,980 / 1,620 / 1,260 2,100 / 1,680 / 1,320 2,160 / 1,740 / 1,380

Heating (Hi / Med / Lo) m³/h 1,260 / 1,020 / 840 1,320 / 1,020 / 840 1,980 / 1,620 / 1,260 2,100 / 1,680 / 1,320 1,980 / 1,620 / 1,260 2,100 / 1,680 / 1,320 2,160 / 1,740 / 1,380Moisture removal volume l/h 3.4 4.2 6.0 7.9 6.0 7.9 9.0Sound pressure level 5) Cooling (Hi / Med / Lo) dB(A) 36 / 31 / 28 37 / 31 / 28 44 / 38 / 32 45 / 39 / 33 44 / 38 / 32 45 / 39 / 33 46 / 40 / 34

Heating (Hi / Med / Lo) dB(A) 36 / 31 / 28 37 / 31 / 28 44 / 38 / 32 45 / 39 / 33 44 / 38 / 32 45 / 39 / 33 46 / 40 / 34Sound power level Cooling (Hi / Med / Lo) dB 53 / 48 / 45 54 / 48 / 45 62 / 55 / 49 63 / 56 / 50 62 / 55 / 49 63 / 56 / 50 64 / 57 / 51

Heating (Hi / Med / Lo) dB 53 / 48 / 45 54 / 48 / 45 62 / 55 / 49 63 / 56 / 50 62 / 55 / 49 63 / 56 / 50 64 / 57 / 51Dimensions (H x W x D) Indoor mm 256 x 840 x 840 256 x 840 x 840 319 x 840 x 840 319 x 840 x 840 319 x 840 x 840 319 x 840 x 840 319 x 840 x 840

Panel mm 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950Net weight Indoor (Panel) kg 24 (4) 24 (4) 27 (4) 27 (4) 27 (4) 27 (4) 27 (4)Outdoor unitPower source V 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 380 / 400 / 415 380 / 400 / 415 380 / 400 / 415Recommended fuse A 20 20 25 30 16 16 16Connection mm² 2.5 2.5 4 6 2.5 2.5 2.5Current Cooling A 8.30 / 7.90 / 7.60 10.70 / 10.30 / 9.80 15.10 / 14.40 / 13.80 19.2 / 18.4 / 17.6 5.10 / 4.85 / 4.70 6.35 / 6.05 / 5.80 6.85 / 6.50 / 6.25

Heating A 7.20 / 6.90 / 6.60 9.10 / 8.70 / 8.30 12.00 / 11.60 / 11.20 15.4 / 14.8 / 14.2 4.15 / 3.95 / 3.80 5.15 / 4.90 / 4.70 5.65 / 5.35 / 5.20Air volume Cooling / Heating m³/h 1,800 / 2,100 2340 4,560 / 4,020 4,800 / 4,380 4,560 / 4,020 4,800 / 4,380 8,100 / 7,200Sound pressure level Cooling / Heating (Hi) dB(A) 46 / 50 50 / 52 54 / 54 56 / 56 54 / 54 56 / 56 54 / 53Sound power level Cooling / Heating (Hi) dB 65 / 69 70 / 70 70 / 70 73 / 73 70 / 70 73 / 73 71 / 70Dimensions H x W x D mm 569 x 790 x 285 569 x 790 x 285 996 x 940 x 340 996 x 940 x 340 996 x 940 x 340 996 x 940 x 340 1,416 x 940 x 340Net weight kg 42 42 73 85 73 85 98Piping connections Liquid pipe / Gas pipe Inch (mm) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88)Refrigerant loading R410A kg 1.7 1.7 2.60 3.20 2.60 3.20 3.4Elevation difference (in/out) 6) Max m 30 30 30 30 30 30 30Piping length Min / Max m 5 / 50 5 / 50 5 / 50 5 / 50 5 / 50 5 / 50 5 / 50Precharge length Max m 20 20 30 30 30 30 30Additional charge g/m 40 40 50 50 50 50 50Operating range Cooling Min / Max °C -10 / +43 -10 / +43 -10 / +43 -10 / +43 -10 / +43 -10 / +43 -10 / +43

Heating Min / Max °C -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24

U-60PEY1E5 U-71PEY1E5

U-100PEY1E5 U-125PEY1E5

U-100PEY1E8 U-125PEY1E8

Possibleto use on

R22 pipings

R22 RENEWAL

5 yearcompressorwarranty

6.80 A++SEER

SEASONAL ENERGY EFFICIENCY RATIO

4.00 A+SCOP

SEASONAL COEFFICIENT OF PERFORMANCE

INTERNET CONTROL READY: Optional. ESEER and SCOP: For KIT-60PUY1E5A. 5 YEARS COMPRESSOR WARRANTY: Only for PRO partners.

U-140PEY1E8

Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.1) ESEER is calculated in base Eurovent IPLV for SBEM for U1 indoor unit SEER=a(EER25)+b(EER50)+c(EER75)+d(EER100) where EER25, EER50, EER75 and EER100 are the EER measured value at 25%, 50%, 75% and 100% part load for temperatures 20, 25, 30 and 35°C DB, respectively. a, b, c and d are values assigned for an office type. These values are given as a=0.2, b=0.36, c=0.32 and d=0.03. The internal temperatures are taken at 27°C DB and 19°C WB. 2) The annual consumption(ErP) is calculated by formula determined by ErP regulation. 3) Heating capacity is calculated including defrost factor correction. 4) SCOP is calculated in base Eurovent IPLV for SBEM with U1 indoor unit including defrost correction factor. 5) The Sound pressure level of the units shows the value measured of a position

InternetControlReady

INTERNET CONTROL

OPTIONAL

4 WAY 90x90 CASSETTEPACi STANDARD AND ELITE INVERTER+

The 4 Way 90x90 Cassette incorporates many new benefits thanks to advances in design and technology.

Technical Focus

· New Circle Flow Flap for more even temp. distribution· Higher efficiency split fin· New DC fan motor· Highly efficient and silent turbo fan· Individual flap control for flexible air flow direction· Easy to clean suction grill & flap· Special adjustment for high ceiling application· DC FAN for better efficiency and control· Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The

external device can be control by the remote control of the Panasonic indoor unit

142

ELITE

ELITE

PanelCZ-KPU21

360ºair flow

Single Phase Three Phase5.0 kW 6.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kWKIT-50PU1E5A* KIT-60PU1E5A* KIT-71PU1E5A* KIT-100PU1E5A* KIT-125PU1E5A* KIT-140PU1E5A* KIT-71PU1E8A* KIT-100PU1E8A* KIT-125PU1E8A* KIT-140PU1E8A*S-50PU1E5A S-60PU1E5A S-71PU1E5A S-100PU1E5A S-125PU1E5A S-140PU1E5A S-71PU1E5A S-100PU1E5A S-125PU1E5A S-140PU1E5AU-50PE1E5 U-60PE1E5A U-71PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8ACZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC25.0 (1.5 - 5.6) 6.0 (2.5 - 7.1) 7.1 (2.5 - 8.0) 10.0 (3.3 - 12.5) 12.5 (3.3 - 14.0) 14.0 (3.3 - 15.5) 7.1 (3.2 - 8.0) 10.0 (3.3 - 12.5) 12.5 (3.3 - 14.0) 14.0 (3.3 - 15.5)

6.5 i 7.4 i 7.4 i 6.6 i 4.26 1) 3.84 1) 6.8 i 6.5 i 4.26 1) 3.84 1)

5.0 6.0 7.1 10.0 — — 7.1 10.0 — —1.350 (0.260 - 2.000) 1.480 (0.450 - 2.000) 1.800 (0.450 - 2.650) 2.380 (0.840 - 3.700) 3.470 (0.840 - 4.600) 4.310 (0.840 - 6.000) 1.800 (0.560 - 2.650) 2.380 (0.840 - 3.700) 3.470 (0.840 - 4.600) 4.310 (0.840 - 6.000)269 284 336 530 — — 365 538 — —5.6 (1.5 - 6.5) 7.0 (2.0 - 8.0) 8.0 (2.0 - 9.0) 11.2 (4.1 - 14.0) 14.0 (4.1 - 16.0) 16.0 (4.1 - 18.0) 8.0 (2.8 - 9.0) 11.2 (4.1 - 14.0) 14.0 (4.1 - 16.0) 16.0 (4.1 - 18.0)3.62 5.85 6.69 9.63 11.80 13.98 6.69 9.63 11.80 13.983.08 5.74 6.80 9.05 10.84 11.42 6.80 9.05 10.84 11.42

3.8 a 4.1 h 4.1 h 4.2 h 3.63 4) 3.41 4) 4.0 h 4.2 h 3.63 4) 3.41 4)

4.0 6.0 7.1 10.0 — — 7.1 10.0 — —1.430 (0.220 - 2.300) 1.810 (0.400 - 2.480) 2.000 (0.400 - 2.900) 2.600 (0.900 - 4.400) 3.500 (0.900 - 5.200) 4.330 (0.900 - 5.900) 2.000 (0.500 - 2.900) 2.600 (0.900 - 4.400) 3.500 (0.900 - 5.200) 4.330 (0.900 - 5.900)1,474 2,047 2,424 3,333 — — 2,485 3,333 — —

960 / 810 / 720 1,260 / 1,020 / 840 1,320 / 1,020 / 840 1,980 / 1,620 / 1,260 2,100 / 1,680 / 1,320 2,160 / 1,740 / 1,380 1,320 / 1,020 / 840 1,980 / 1,620 / 1,260 2,100 / 1,680 / 1,320 2,160 / 1,740 / 1,380960 / 810 / 720 1,260 / 1,020 / 840 1,320 / 1,020 / 840 1,980 / 1,620 / 1,260 2,100 / 1,680 / 1,320 2,160 / 1,740 / 1,380 1,320 / 1,020 / 840 1,980 / 1,620 / 1,260 2,100 / 1,680 / 1,320 2,160 / 1,740 / 1,380 2.8 3.4 4.2 6.0 7.9 9.0 4.2 6.0 7.9 9.032 / 29 / 27 36 / 31 / 28 37 / 31 / 28 44 / 38 / 32 45 / 39 / 33 46 / 40 / 34 37 / 31 / 28 44 / 38 / 32 45 / 39 / 33 46 / 40 / 3432 / 29 / 27 36 / 31 / 28 37 / 31 / 28 44 / 38 / 32 45 / 39 / 33 46 / 40 / 34 37 / 31 / 28 44 / 38 / 32 45 / 39 / 33 46 / 40 / 3449 / 46 / 44 53 / 48 / 45 54 / 48 / 45 62 / 55 / 49 63 / 56 / 50 64 / 57 / 51 54 / 48 / 45 62 / 55 / 49 63 / 56 / 50 64 / 57 / 5149 / 46 / 44 53 / 48 / 45 54 / 48 / 45 62 / 55 / 49 63 / 56 / 50 64 / 57 / 51 54 / 48 / 45 62 / 55 / 49 63 / 56 / 50 64 / 57 / 51256 x 840 x 840 256 x 840 x 840 256 x 840 x 840 319 x 840 x 840 319 x 840 x 840 319 x 840 x 840 256 x 840 x 840 319 x 840 x 840 319 x 840 x 840 319 x 840 x 84033.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 95023 (4) 24 (4) 24 (4) 27 (4) 27 (4) 27 (4) 24 (4) 27 (4) 27 (4) 27 (4)

220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 380 / 400 / 415 380 / 400 / 415 380 / 400 / 415 380 / 400 / 41516 20 20 25 30 16 16 16 16 162.5 2.5 2.5 4 6 2.5 2.5 2.5 2.5 2.56.50 / 6.20 / 5.95 7.15 / 6.90 / 6.70 8.40 / 8.10 / 7.90 10.7 / 10.3 / 9.90 15.8 / 15.3 / 14.8 19.6 / 19.0 / 18.4 2.80 / 2.70 / 2.60 3.70 / 3.50 / 3.40 5.45 / 5.15 / 5.00 6.75 / 6.45 / 6.206.90 / 6.60 / 6.30 8.50 / 8.20 / 7.95 9.30 / 9.00 / 8.70 11.8 / 11.4 / 11.0 15.9 / 15.4 / 14.9 19.8 / 19.2 / 18.6 3.10 / 3.00 / 2.90 4.05 / 3.85 / 3.75 5.50 / 5.20 / 5.05 6.85 / 6.50 / 6.251,800 / 2,100 3,600 / 3,600 3,600 / 3,600 6,600 / 5,700 7,800 / 6,600 8,100 / 7,200 3,600 / 3,600 6,600 / 5,700 7,800 / 6,600 8,100 / 7,20046 / 50 48 / 50 48 / 50 52 / 52 53 / 53 54 / 55 48 / 50 52 / 52 53 / 53 54 / 5565 / 69 65 / 67 65 / 67 69 / 69 70 / 70 71 / 71 65 / 67 69 / 69 70 / 70 71 / 71569 x 790 x 285 996 x 940 x 340 996 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 340 996 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 34042 68 69 98 98 98 71 98 98 981/4 (6.35) / 1/2 (12.7) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88) 3/8 (9.52) / 5/8 (15.88)1.65 2 2.35 3.4 3.4 3.4 2.35 3.4 3.4 3.430 30 30 30 30 30 30 30 30 305 / 40 5 / 50 5 / 50 5 / 75 5 / 75 5 / 75 5 / 50 5 / 75 5 / 75 5 / 7530 30 30 30 30 30 30 30 30 3020 50 50 50 50 50 50 50 50 50-15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46-20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24

U-60PE1E5A U-71PE1E5A U-71PE1E8A

U-100PE1E5A U-125PE1E5A U-140PE1E5A

U-100PE1E8A U-125PE1E8A U-140PE1E8A

1 meter in front of the main body and 1.5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 6) When installing the outdoor unit at a higher position than the indoor unit. // Recommended fuse for the indoor 3A.* Available from May 2014.For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu

Energy saving

Down to

-15°C incooling mode

OUTDOORTEMPERATURE

Down to

-20°C inheating mode

OUTDOORTEMPERATURE

Easycontrolby BMS

CONNECTIVITY

Possibleto use on

R22 pipings

R22 RENEWAL

5 yearcompressorwarranty

7.40 A+++SEER

SEASONAL ENERGY EFFICIENCY RATIO

4.10 A+SCOP

SEASONAL COEFFICIENT OF PERFORMANCE

INTERNET CONTROL READY: Optional. ESEER and SCOP: For KIT-60PU1E5A and KIT-71PU1E5A. 5 YEARS COMPRESSOR WARRANTY: Only for PRO partners.

U-50PE1E5

InternetControlReady

INTERNET CONTROL

OPTIONAL

Compatible with all Panasonic connectivity solutions. For detailed information go to the VRF Control Systems section.

Optional ControllerTimer remote controllerCZ-RTC2

Optional ControllerWired remote controllerCZ-RTC3

Optional Controller Wireless remote controllerCZ-RWSU2

Optional Controller Simplified remote controllerCZ-RE2C2

HIGH

HEATING

CAPACITY

AT -7°C

143

COMMERCIAL PACi ELITE / STANDARDNEW

STANDARD

STANDARD

Single Phase Three Phase6.0 kW 7.1 kW 10.0 kW 12.5 kW 10.0 kW 12.5 kW 14.0 kW

KIT KIT-60PNY1E5A* KIT-71PNY1E5A* KIT-100PNY1E5A* KIT-125PNY1E5A* KIT-100PNY1E8A* KIT-125PNY1E8A* KIT-140PNY1E8A*Indoor S-60PN1E5A S-71PN1E5A S-100PN1E5A S-125PN1E5A S-100PN1E5A S-125PN1E5A S-140PN1E5AOutdoor U-60PEY1E5 U-71PEY1E5 U-100PEY1E5 U-125PEY1E5 U-100PEY1E8 U-125PEY1E8 U-140PEY1E8Timer remote controller CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2Cooling capacity Nominal (Min - Max) kW 6.0 (2.0 - 7.0) 7.1 (2.0 - 7.7) 10.0 (2.7 - 11.5) 12.5 (3.8 - 13.5) 10.0 (2.7 - 11.5) 12.5 (3.8 - 13.5) 14.0 (3.3 - 15.5)ESEER Nominal (Min - Max) W/W 4.7 b 5.0 b 5.3 a 3.66 1) 5.2 a 3.66 1) 3.80 1)

Pdesign kW 6.0 7.1 10.0 — 10.0 — —Power input cooling Nominal (Min - Max) kW 1.990 (0.325 - 2.940) 2.570 (0.325 - 3.230) 3.555 (0.570 - 4.300) 4.445 (0.950 - 5.200) 3.555 (0.570 - 4.300) 4.445 (0.950 - 5.200) 4.700 (0.840 - 6.000)Annual energy consumption (ErP) 2) kWh/a 444 496 660 — 673 — —Heating capacity Nominal (Min - Max) kW 6.0 (1.8 - 7.0) 7.1 (1.8 - 8.1) 10.0 (2.1 - 13.8) 12.5 (3.4 - 15.0) 10.0 (2.1 - 13.8) 12.5 (3.4 - 15.0) 14.0 (4.1 - 16.0)Heating capacity at -7°C 3) Nominal kW 4.39 4.32 7.22 9.14 7.22 9.14 11.68Heating capacity at -15°C 3) Nominal kW — — — — — — —SCOP Nominal (Min - Max) W/W 3.8 a 3.8 a 3.8 a 3.40 4) 3.8 a 3.40 4) 3.52 4)

Pdesign at -10°C kW 4.8 5.3 7.6 — 7.6 — —Power input heating Nominal (Min - Max) kW 1.660 (0.275 - 2.420) 2.080 (0.275 - 2.780) 2.935 (0.450 - 4.100) 3.665 (0.780 - 4.600) 2.935 (0.450 - 4.100) 3.665 (0.780 - 4.600) 3.880 (1.050 - 5.400)Annual energy consumption (ErP) 2) kWh/a 1,757 1,952 2,800 — 2,800 — —Indoor unitExternal static pressure 5) Nominal (Min - Max) Pa 50 (10 - 80) 50 (10 - 80) 50 (10 - 80) 50 (10 - 80) 50 (10 - 80) 50 (10 - 80) 50 (10 - 80)Air volume Cooling / Heating m³/h 1,320 / 1,320 1,320 / 1,320 2,160 / 2,160 2,280 / 2,280 2,160 / 2,160 2,280 / 2,280 2,400 / 2,400Moisture removal volume l/h 3.4 4.2 6.0 7.9 6.0 7.9 9.0Sound pressure level 6) Cooling (Hi / Med / Lo) dB(A) 43 / 41 / 36 43 / 41 / 36 44 / 42 / 37 45 / 43 / 38 44 / 42 / 37 45 / 43 / 38 46 / 44 / 39

Heating (Hi / Med / Lo) dB(A) 43 / 41 / 36 43 / 41 / 36 44 / 42 / 37 45 / 43 / 38 44 / 42 / 37 45 / 43 / 38 46 / 44 / 39Sound power level Cooling (Hi / Med / Lo) dB 60 / 58 / 53 60 / 58 / 53 65 / 63 / 58 66 / 64 / 59 65 / 63 / 58 66 / 64 / 59 67 / 65 / 60

Heating (Hi / Med / Lo) dB 60 / 58 / 53 60 / 58 / 53 65 / 63 / 58 66 / 64 / 59 65 / 63 / 58 66 / 64 / 59 67 / 65 / 60Dimensions 7) H x W x D mm 250 x 1,000(+100) x 650 250 x 1,000(+100) x 650 250 x 1,200(+100) x 650 250 x 1,200(+100) x 650 250 x 1,200(+100) x 650 250 x 1,200(+100) x 650 250 x 1,200(+100) x 650Net weight kg 32 32 41 41 41 41 41Outdoor unitPower source V 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 380 / 400 / 415 380 / 400 / 415 380 / 400 / 415Recommended fuse A 20 20 25 30 16 16 16Connection mm² 2.5 2.5 4 6 2.5 2.5 2.5Current Cooling A 9.1 / 8.7 / 8.4 12.0 / 11.5 / 11.0 16.0 / 15.3 / 14.8 20.1 / 19.3 / 18.7 5.45 / 5.20 / 5.05 6.85 / 6.50 / 6.25 7.05 / 6.70 / 6.45

Heating A 7.5 / 7.2 / 6.9 9.6 / 9.2 / 8.9 13.0 / 12.5 / 12.1 16.5 / 15.8 / 15.2 4.45 / 4.25 / 4.10 5.55 / 5.30 / 5.10 5.90 / 5.60 / 5.40Air volume Cooling / Heating m³/h 1,800 / 2,100 2,340 4,560 / 4,020 4,800 / 4,380 4,560 / 4,020 4,800 / 4,380 8,100 / 7,200Sound pressure level Cooling / Heating (Hi) dB(A) 46 / 50 50 / 52 54 / 54 56 / 56 54 / 54 56 / 56 54 / 53Sound power level Cooling / Heating (Hi) dB 65 / 69 70 / 70 70 / 70 73 / 73 70 / 70 73 / 73 71 / 70Dimensions H x W x D mm 569 x 790 x 285 569 x 790 x 285 996 x 940 x 340 996 x 940 x 340 996 x 940 x 340 996 x 940 x 340 1,416 x 940 x 340Net weight kg 42 42 73 85 73 85 98Piping connections Liquid pipe Inch (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)

Gas pipe Inch (mm) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)Refrigerant loading R410A kg 1.7 1.7 2.60 3.20 2.60 3.20 3.4Elevation difference (in/out) 8) Max m 30 30 30 30 30 30 30Piping length Min / Max m 5 / 50 5 / 50 5 / 50 5 / 50 5 / 50 5 / 50 5 / 50Precharge length Max m 20 20 30 30 30 30 30Additional charge g/m 40 40 50 50 50 50 50Operating range Cooling Min / Max °C -10 / +43 -10 / +43 -10 / +43 -10 / +43 -10 / +43 -10 / +43 -10 / +43

Heating Min / Max °C -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24

Energy saving

Easycontrolby BMS

CONNECTIVITY

Possibleto use on

R22 pipings

R22 RENEWAL

5 yearcompressorwarranty

5.30 ASEER

SEASONAL ENERGY EFFICIENCY RATIO

3.80 ASCOP

SEASONAL COEFFICIENT OF PERFORMANCE

INTERNET CONTROL READY: Optional. ESEER and SCOP: For KIT-100PNY1E5A. 5 YEARS COMPRESSOR WARRANTY: Only for PRO partners.

Down to

-10°C incooling mode

OUTDOORTEMPERATURE

Down to

-15°C inheating mode

OUTDOORTEMPERATURE

U-60PEY1E5 U-71PEY1E5

U-100PEY1E5 U-125PEY1E5

U-100PEY1E8 U-125PEY1E8

U-140PEY1E8

InternetControlReady

INTERNET CONTROL

OPTIONAL

LOW STATIC PRESSURE HIDE AWAYPACi STANDARD AND ELITE INVERTER+

The depth of only 250mm provides greater installation flexibility and the unit can be used in more applications. Ideal for sites with narrow ceiling voids.

Technical Focus

· Compact indoor units without loosing static pressure (Only 250 mm high)· 50 Pa static pressure· Easy maintenance and service via external electrical box· 3 speed centrifugal fan through wired or wireless remote control· DC FAN for better efficiency and control· Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB.

The external device can be control by the remote control of the Panasonic indoor unit

Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.1) ESEER is calculated in base Eurovent IPLV for SBEM for U1 indoor unit SEER=a(EER25)+b(EER50)+c(EER75)+d(EER100) where EER25, EER50, EER75 and EER100 are the EER measured value at 25%, 50%, 75% and 100% part load for temperatures 20, 25, 30 and 35°C DB, respectively. a, b, c and d are values assigned for an office type. These values are given as a=0.2, b=0.36, c=0.32 and d=0.03. The internal temperatures are taken at 27°C DB and 19°C WB. 2) The annual consumption(ErP) is calculated by formula determined by ErP regulation. 3) Heating capacity is calculated including defrost factor correction. 4) SCOP is calculated in base Eurovent IPLV for SBEM with U1 indoor unit including defrost correction factor. 5) Medium External static pressure setting from factory. 6) The Sound pressure

144

ELITE

ELITE

Single Phase Three Phase5.0 kW 6.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kWKIT-50PN1E5A* KIT-60PN1E5A* KIT-71PN1E5A* KIT-100PN1E5A* KIT-125PN1E5A* KIT-140PN1E5A* KIT-71PN1E8A* KIT-100PN1E8A* KIT-125PN1E8A* KIT-140PN1E8A*S-50PN1E5A S-60PN1E5A S-71PN1E5A S-100PN1E5A S-125PN1E5A S-140PN1E5A S-71PN1E5A S-100PN1E5A S-125PN1E5A S-140PN1E5AU-50PE1E5 U-60PE1E5A U-71PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8ACZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC25.0 (1.5 - 5.6) 6.0 (2.5 - 7.1) 7.1 (2.5 - 8.0) 10.0 (3.3 - 12.5) 12.5 (3.3 - 14.0) 14.0 (3.3 - 15.5) 7.1 (2.5 - 8.0) 10.0 (3.3 - 12.5) 12.5 (3.3 - 14.0) 14.0 (3.3 - 15.5)

4.6 b 5.5 a 5.5 a 6.0 h 4.26 1) 3.84 1) 5.2 a 5.8 h 4.26 1) 3.84 1)

5.0 6.0 7.1 10.0 — — 7.1 10.0 — —1.560 (0.260 - 2.310) 1.850 (0.550 - 2.105) 2.150 (0.550 - 2.750) 2.670 (0.870 - 3.800) 3.890 (1.000 - 4.800) 4.650 (1.000 - 6.200) 2.150 (0.660 - 2.750) 2.670 (0.870 - 3.800) 3.890 (1.000 - 4.800) 4.650 (1.000 - 6.200)380 382 452 583 — — 477 603 — —5.6 (1.5 - 6.3) 7.0 (2.0 - 8.0) 8.0 (2.0 - 9.0) 11.2 (4.1 - 14.0) 14.0 (4.1 - 16.0) 16.0 (4.1 - 18.0) 8.0 (2.0 - 9.0) 11.2 (4.1 - 14.0) 14.0 (4.1 - 16.0) 16.0 (4.1 - 18.0)3.62 5.85 6.69 9.63 11.80 13.98 6.69 9.63 11.80 13.983.08 5.74 6.80 9.05 10.84 11.42 6.80 9.05 10.84 11.42

3.8 a 3.8 a 3.7 a 3.9 a 3.63 4) 3.41 4) 3.7 a 3.8 a 3.63 4) 3.41 4)

3.8 5.6 6.5 10.0 — — 6.5 10.0 — —1.740 (0.220 - 2.520) 1.940 (0.500 - 2.585) 2.260 (0.500 - 2.920) 2.950 (0.980 - 4.500) 3.880 (1.050 - 5.400) 4.690 (1.050 - 6.100) 2.260 (0.600 - 3.000) 2.950 (0.980 - 4.500) 3.880 (1.050 - 5.400) 4.690 (1.050 - 6.100)1,400 2,061 2,458 3,590 — — 2,458 3,684 — —

50 (10 - 80) 50 (10 - 80) 50 (10 - 80) 50 (10 - 80) 50 (10 - 80) 50 (10 - 80) 50 (10 - 80) 50 (10 - 80) 50 (10 - 80) 50 (10 - 80)960 / 960 1,320 / 1,320 1,320 / 1,320 2,160 / 2,160 2,280 / 2,280 2,400 / 2,400 1,320 / 1,320 2,160 / 2,160 2,280 / 2,280 2,400 / 2,4002.8 3.4 4.2 6.0 7.9 9.0 4.2 6.0 7.9 9.041 / 39 / 35 43 / 41 / 36 43 / 41 / 36 44 / 42 / 37 45 / 43 / 38 46 / 44 / 39 43 / 41 / 36 44 / 42 / 37 45 / 43 / 38 46 / 44 / 3941 / 39 / 35 43 / 41 / 36 43 / 41 / 36 44 / 42 / 37 45 / 43 / 38 46 / 44 / 39 43 / 41 / 36 44 / 42 / 37 45 / 43 / 38 46 / 44 / 3958 / 56 / 52 60 / 58 / 53 60 / 58 / 53 65 / 63 / 58 66 / 64 / 59 67 / 65 / 60 60 / 58 / 53 65 / 63 / 58 66 / 64 / 59 67 / 65 / 6058 / 56 / 52 60 / 58 / 53 60 / 58 / 53 65 / 63 / 58 66 / 64 / 59 67 / 65 / 60 60 / 58 / 53 65 / 63 / 58 66 / 64 / 59 67 / 65 / 60250x780(+100)x650 250x1,000(+100)x650 250x1,000(+100)x650 250x1,200(+100)x650 250x1,200(+100)x650 250x1,200(+100)x650 250x1,000(+100)x650 250x1,200(+100)x650 250x1,200(+100)x650 250x1,200(+100)x65029 32 32 41 41 41 32 41 41 41

220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 380 / 400 / 415 380 / 400 / 415 380 / 400 / 415 380 / 400 / 41516 20 20 25 30 16 16 16 16 162.5 2.5 2.5 4 6 2.5 2.5 2.5 2.5 2.57.10 / 6.80 / 6.60 8.20 / 8.00 / 7.80 9.70 / 9.40 / 9.20 11.6 / 11.2 / 10.9 17.4 / 16.9 / 16.4 20.5 / 20.1 / 19.5 3.25 / 3.10 / 3.00 3.95 / 3.75 / 3.60 5.80 / 5.50 / 5.30 6.95 / 6.60 / 6.358.00 / 7.70 / 7.40 8.60 / 8.40 / 8.20 10.2 / 9.90 / 9.70 12.8 / 12.5 / 12.2 17.3 / 16.8 / 16.3 20.6 / 20.2 / 19.6 3.35 / 3.20 / 3.10 4.35 / 4.15 / 4.00 5.80 / 5.50 / 5.30 7.00 / 6.65 / 6.451,800 / 2,100 3,600 / 3,600 3,600 / 3,600 6,600 / 5,700 7,800 / 6,600 8,100 / 7,200 3,600 / 3,600 6,600 / 5,700 7,800 / 6,600 8,100 / 7,20046 / 50 48 / 50 48 / 50 52 / 52 53 / 53 54 / 55 48 / 50 52 / 52 53 / 53 54 / 5565 / 69 65 / 67 65 / 67 69 / 69 70 / 70 71 / 71 65 / 67 69 / 69 70 / 70 71 / 71569 x 790 x 285 996 x 940 x 340 996 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 340 996 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 34042 68 69 98 98 98 71 98 98 981/4 (6.35) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)1/2 (12.7) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)1.65 2 2.35 3.4 3.4 3.4 2.35 3.4 3.4 3.430 30 30 30 30 30 30 30 30 305 - 40 5 - 50 5 - 50 5 - 75 5 - 75 5 - 75 5 - 50 5 - 75 5 - 75 5 - 7530 30 30 30 30 30 30 30 30 3020 50 50 50 50 50 50 50 50 50-15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46-20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24

Energy saving

Down to

-15°C incooling mode

OUTDOORTEMPERATURE

Down to

-20°C inheating mode

OUTDOORTEMPERATURE

Easycontrolby BMS

CONNECTIVITY

Possibleto use on

R22 pipings

R22 RENEWAL

5 yearcompressorwarranty

6.00 A+SEER

SEASONAL ENERGY EFFICIENCY RATIO

5.30 A+++SCOP

SEASONAL COEFFICIENT OF PERFORMANCE

INTERNET CONTROL READY: Optional. ESEER and SCOP: For KIT-100PN1E5A. 5 YEARS COMPRESSOR WARRANTY: Only for PRO partners.

U-60PE1E5A U-71PE1E5A U-71PE1E8A

U-100PE1E5A U-125PE1E5A U-140PE1E5A

U-100PE1E8A U-125PE1E8A U-140PE1E8A

U-50PE1E5

InternetControlReady

INTERNET CONTROL

OPTIONAL

Compatible with all Panasonic connectivity solutions. For detailed information go to the VRF Control Systems section.

Optional ControllerTimer remote controllerCZ-RTC2

Optional ControllerWired remote controllerCZ-RTC3

Optional Controller Wireless remote controllerCZ-RWSK2 + CZ-RWSC3

Optional Controller Simplified remote controllerCZ-RE2C2

level of the units shows the value measured of a position 1 meter in front of the main body and 1.5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 7) Add 100 mm for piping port. 8) When installing the outdoor unit at a higher position than the indoor unit. // Recommended fuse for the indoor 3A. // * Available from May 2014.For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu

HIGH

HEATING

CAPACITY

AT -7°C

145

COMMERCIAL PACi ELITE / STANDARDNEW

STANDARD

STANDARD

Single Phase Three Phase6.0 kW 7.1 kW 10.0 kW 12.5 kW 10.0 kW 12.5 kW 14.0 kW

KIT KIT-60PFY1E5A* KIT-71PFY1E5A* KIT-100PFY1E5A* KIT-125PFY1E5A* KIT-100PFY1E8A* KIT-125PFY1E8A* KIT-140PFY1E8A*Indoor S-60PF1E5A S-71PF1E5A S-100PF1E5A S-125PF1E5A S-100PF1E5A S-125PF1E5A S-140PF1E5AOutdoor U-60PEY1E5 U-71PEY1E5 U-100PEY1E5 U-125PEY1E5 U-100PEY1E8 U-125PEY1E8 U-140PEY1E8Timer remote controller CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2Cooling capacity Nominal (Min - Max) kW 6.0 (2.0 - 7.0) 7.1 (2.0 - 7.7) 10.0 (2.7 - 11.5) 12.5 (3.8 - 13.5) 10.0 (2.7 - 11.5) 12.5 (3.8 - 13.5) 14.0 (3.3 - 15.5)ESEER Nominal (Min - Max) W/W 5.4 a 5.3 a 5.4 a 3.66 1) 5.2 a 3.66 1) 3.80 1)

Pdesign kW 6.0 7.1 10.0 — 10.0 — —Power input cooling Nominal (Min - Max) kW 1.930 (0.325 - 2.850) 2.570 (0.325 - 3.270) 3.320 (0.530 - 4.200) 4.100 (0.900 - 5.000) 3.320 (0.530 - 4.200) 4.100 (0.900 - 5.000) 4.350 (0.840 - 6.000)Annual energy consumption (ErP) 2) kWh/a 389 469 648 — 673 — —Heating capacity Nominal (Min - Max) kW 6.0 (1.8 - 7.0) 7.1 (1.8 - 8.1) 10.0 (2.1 - 13.8) 12.5 (3.4 - 15.0) 10.0 (2.1 - 13.8) 12.5 (3.4 - 15.0) 14.0 (4.1 - 16.0)Heating capacity at -7°C 3) Nominal kW 4.39 4.32 7.22 9.14 7.22 9.14 11.68Heating capacity at -15°C 3) Nominal kW — — — — — — —SCOP Nominal (Min - Max) W/W 3.8 a 3.8 a 3.8 a 3.40 4) 3.8 a 3.40 4) 3.52 4)

Pdesign at -10°C kW 5.0 5.5 9.5 — 9.5 — —Power input heating Nominal (Min - Max) kW 1.410 (0.275 - 2.055) 1.800 (0.275 - 2.380) 2.630 (0.410 - 4.000) 3.270 (0.730 - 4.400) 2.630 (0.410 - 4.000) 3.270 (0.730 - 4.400) 3.580 (0.900 - 5.200)Annual energy consumption (ErP) 2) kWh/a 1,842 2,026 3,500 — 3,500 — —Indoor unitExternal static pressure 5) Nominal (Min - Max) Pa 70 (10 - 150) 70 (10 - 150) 100 (10 - 150) 100 (10 - 150) 100 (10 - 150) 100 (10 - 150) 100 (10 - 150)Air volume Cooling (Hi / Med / Lo) m³/h 1,260 / 1,140 / 900 1,260 / 1,140 / 900 1,920 / 1,560 / 1,260 2,040 / 1,740 / 1,380 1,920 / 1,560 / 1,260 2,040 / 1,740 / 1,380 2,160 / 1,920 / 1,500

Heating (Hi / Med / Lo) m³/h 1,260 / 1,140 / 900 1,260 / 1,140 / 900 1,920 / 1,560 / 1,260 2,040 / 1,740 / 1,380 1,920 / 1,560 / 1,260 2,040 / 1,740 / 1,380 2,160 / 1,920 / 1,500 Moisture removal volume l/h 3.4 4.2 6.0 7.9 6.0 7.9 9.0Sound pressure level 6) Cooling (Hi / Med / Lo) dB(A) 35 / 32 / 26 35 / 32 / 26 38 / 34 / 31 39 / 35 / 32 38 / 34 / 31 39 / 35 / 32 40 / 36 / 33

Heating (Hi / Med / Lo) dB(A) 35 / 32 / 26 35 / 32 / 26 38 / 34 / 31 39 / 35 / 32 38 / 34 / 31 39 / 35 / 32 40 / 36 / 33Sound power level Cooling (Hi / Med / Lo) dB 57 / 54 / 48 57 / 54 / 48 60 / 56 / 53 61 / 57 / 54 60 / 56 / 53 61 / 57 / 54 62 / 58 / 55

Heating (Hi / Med / Lo) dB 57 / 54 / 48 57 / 54 / 48 60 / 56 / 53 61 / 57 / 54 60 / 56 / 53 61 / 57 / 54 62 / 58 / 55Dimensions H x W x D mm 290 x 1,000 x 700 290 x 1,000 x 700 290 x 1,400 x 700 290 x 1,400 x 700 290 x 1,400 x 700 290 x 1,400 x 700 290 x 1,400 x 700Net weight kg 33 33 45 45 45 45 45Outdoor unitPower source V 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 380 / 400 / 415 380 / 400 / 415 380 / 400 / 415Recommended fuse A 20 20 25 30 16 16 16Connection mm² 2.5 2.5 4 6 2.5 2.5 2.5Current Cooling A 9.00 / 8.65 / 8.30 12.2 / 11.7 / 11.2 15.1 / 14.5 / 13.9 18.8 / 18.0 / 17.2 5.10 / 4.85 / 4.70 6.20 / 5.90 / 5.70 6.75 / 6.45 / 6.25

Heating A 6.40 / 6.10 / 5.90 8.30 / 7.90 / 7.60 11.8 / 11.2 / 10.7 14.6 / 14.0 / 13.4 4.05 / 3.80 / 3.65 4.90 / 4.65 / 4.50 5.60 / 5.40 / 5.20Air volume Cooling / Heating m³/h 1,800 / 2,100 2,340 / 2,340 4,560 / 4,020 4,800 / 4,380 4,560 / 4,020 4,800 / 4,380 8,100 / 7,200Sound pressure level Cooling / Heating (Hi) dB(A) 46 / 50 50 / 52 54 / 54 56 / 56 54 / 54 56 / 56 54 / 53Sound power level Cooling / Heating (Hi) dB 65 / 69 70 / 70 70 / 70 73 / 73 70 / 70 73 / 73 71 / 70Dimensions H x W x D mm 569 x 790 x 285 569 x 790 x 285 996 x 940 x 340 996 x 940 x 340 996 x 940 x 340 996 x 940 x 340 1,416 x 940 x 340Net weight kg 42 42 73 85 73 85 98Piping connections Liquid pipe Inch (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)

Gas pipe Inch (mm) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)Refrigerant loading R410A kg 1.7 1.7 2.60 3.20 2.60 3.20 3.4Elevation difference (in/out) 7) Max m 30 30 30 30 30 30 30Piping length Min / Max m 5 / 50 5 / 50 5 / 50 5 / 50 5 / 50 5 / 50 5 / 50Precharge length Max m 20 20 30 30 30 30 30Additional charge g/m 40 40 50 50 50 50 50Operating range Cooling Min / Max °C -10 / +43 -10 / +43 -10 / +43 -10 / +43 -10 / +43 -10 / +43 -10 / +43

Heating Min / Max °C -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24

Energy saving

Easycontrolby BMS

CONNECTIVITY

Possibleto use on

R22 pipings

R22 RENEWAL

5 yearcompressorwarranty

5.40 ASEER

SEASONAL ENERGY EFFICIENCY RATIO

3.80 ASCOP

SEASONAL COEFFICIENT OF PERFORMANCE

INTERNET CONTROL READY: Optional. ESEER and SCOP: For KIT-60PFY1E5A and KIT-100PFY1E5A. 5 YEARS COMPRESSOR WARRANTY: Only for PRO partners.

Down to

-10°C incooling mode

OUTDOORTEMPERATURE

Down to

-15°C inheating mode

OUTDOORTEMPERATURE

U-60PEY1E5 U-71PEY1E5

U-100PEY1E5 U-125PEY1E5

U-100PEY1E8 U-125PEY1E8

U-140PEY1E8

InternetControlReady

INTERNET CONTROL

OPTIONAL

HIGH STATIC PRESSURE HIDE AWAYPACi STANDARD AND ELITE INVERTER+

The ducted systems are the ideal solution for flexible, concealed air conditioning and the optional 200mm spigots ensure simple, hassle-free connection to spiral ductwork.

Technical Focus

· Extremely quiet operation from 26 dB(A)· Auto restart after power failure· Auto changeover· Twin, triple and double-twin split options· DC FAN for better efficiency and control· Built in drain pump· Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB.

The external device can be control by the remote control of the Panasonic indoor unit

Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.1) ESEER is calculated in base Eurovent IPLV for SBEM for U1 indoor unit SEER=a(EER25)+b(EER50)+c(EER75)+d(EER100) where EER25, EER50, EER75 and EER100 are the EER measured value at 25%, 50%, 75% and 100% part load for temperatures 20, 25, 30 and 35°C DB, respectively. a, b, c and d are values assigned for an office type. These values are given as a=0.2, b=0.36, c=0.32 and d=0.03. The internal temperatures are taken at 27°C DB and 19°C WB. 2) The annual consumption(ErP) is calculated by formula determined by ErP regulation. 3) Heating capacity is calculated including defrost factor correction. 4) SCOP is calculated in base Eurovent IPLV for SBEM with U1 indoor unit including defrost correction factor. 5) Medium External static pressure setting from factory. 6) The Sound pressure

146

ELITE

ELITE

S-100PF1E5A // S-125PF1E5A // S-140PF1E5A

Single Phase Three Phase5.0 kW 6.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kWKIT-50PF1E5A* KIT-60PF1E5A* KIT-71PF1E5A* KIT-100PF1E5A* KIT-125PF1E5A* KIT-140PF1E5A* KIT-71PF1E8A* KIT-100PF1E8A* KIT-125PF1E8A* KIT-140PF1E8A*S-50PF1E5A S-60PF1E5A S-71PF1E5A S-100PF1E5A S-125PF1E5A S-140PF1E5A S-71PF1E5A S-100PF1E5A S-125PF1E5A S-140PF1E5AU-50PE1E5 U-60PE1E5A U-71PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8ACZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC25.0 (1.5 - 5.6) 6.0 (2.5 - 7.1) 7.1 (2.5 - 8.0) 10.0 (3.3 - 12.5) 12.5 (3.3 - 14.0) 14.0 (3.3 - 15.5) 7.1 (3.2 - 8.0) 10.0 (3.3 - 12.5) 12.5 (3.3 - 14.0) 14.0 (3.3 - 15.5)

5.7 h 6.4 i 6.4 i 5.8 h 4.26 1) 3.84 1) 5.2 a 5.8 h 4.26 1) 3.84 1)

5.0 6.0 7.1 10.0 — — 7.1 10.0 — —1.350 (0.260 - 2.000) 1.540 (0.530 - 2.000) 1.850 (0.530 - 2.650) 2.440 (0.840 - 3.700) 3.570 (0.840 - 4.600) 4.310 (0.840 - 6.000) 1.850 (0.640 - 2.650) 2.440 (0.840 - 3.700) 3.570 (0.840 - 4.600) 4.310 (0.840 - 6.000)307 328 388 603 — — 414 614 — —5.6 (1.5 - 6.5) 7.0 (2.0 - 8.0) 8.0 (2.0 - 9.0) 11.2 (4.1 - 14.0) 14.0 (4.1 - 16.0) 16.0 (4.1 - 18.0) 8.0 (2.8 - 9.0) 11.2 (4.1 - 14.0) 14.0 (4.1 - 16.0) 16.0 (4.1 - 18.0)3.62 5.85 6.69 9.63 11.80 13.98 6.69 9.63 11.80 13.983.08 5.74 6.80 9.05 10.84 11.42 6.80 9.05 10.84 11.42

3.8 a 3.9 a 4.0 h 3.8 a 3.63 4) 3.41 4) 3.7 a 3.8 a 3.63 4) 3.41 4)

4.0 6.0 7.1 10.0 — — 7.1 10.0 — —1.500 (0.220 - 2.400) 1.810 (0.480 - 2.480) 2.080 (0.480 - 2.900) 2.600 (0.900 - 4.400) 3.480 (0.900 - 5.200) 4.440 (0.900 - 5.900) 2.080 (0.580 - 2.900) 2.600 (0.900 - 4.400) 3.480 (0.900 - 5.200) 4.440 (0.900 - 5.900)1,474 2,154 2,485 3,684 — — 2,548 3,684 — —

70 (10 - 150) 70 (10 - 150) 70 (10 - 150) 100 (10 - 150) 100 (10 - 150) 100 (10 - 150) 70 (10 - 150) 100 (10 - 150) 100 (10 - 150) 100 (10 - 150)960 / 900 / 720 1,260 / 1,140 / 900 1,260 / 1,140 / 900 1,920 / 1,560 / 1,260 2,040 / 1,740 / 1,380 2,160 / 1,920 / 1,500 1,260 / 1,140 / 900 1,920 / 1,560 / 1,260 2,040 / 1,740 / 1,380 2,160 / 1,920 / 1,500960 / 900 / 720 1,260 / 1,140 / 900 1,260 / 1,140 / 900 1,920 / 1,560 / 1,260 2,040 / 1,740 / 1,380 2,160 / 1,920 / 1,500 1,260 / 1,140 / 900 1,920 / 1,560 / 1,260 2,040 / 1,740 / 1,380 2,160 / 1,920 / 1,500 2.8 3.4 4.2 6.0 7.9 9.0 4.2 6.0 7.9 9.034 / 30 / 26 35 / 32 / 26 35 / 32 / 26 38 / 34 / 31 39 / 35 / 32 40 / 36 / 33 35 / 32 / 26 38 / 34 / 31 39 / 35 / 32 40 / 36 / 3334 / 30 / 26 35 / 32 / 26 35 / 32 / 26 38 / 34 / 31 39 / 35 / 32 40 / 36 / 33 35 / 32 / 26 38 / 34 / 31 39 / 35 / 32 40 / 36 / 3356 / 52 / 48 57 / 54 / 48 57 / 54 / 48 60 / 56 / 53 61 / 57 / 54 62 / 58 / 55 57 / 54 / 48 60 / 56 / 53 61 / 57 / 54 62 / 58 / 5556 / 52 / 48 57 / 54 / 48 57 / 54 / 48 60 / 56 / 53 61 / 57 / 54 62 / 58 / 55 57 / 54 / 48 60 / 56 / 53 61 / 57 / 54 62 / 58 / 55290 x 800 x 700 290 x 1,000 x 700 290 x 1,000 x 700 290 x 1,400 x 700 290 x 1,400 x 700 290 x 1,400 x 700 290 x 1,000 x 700 290 x 1,400 x 700 290 x 1,400 x 700 290 x 1,400 x 70028 33 33 45 45 45 33 45 45 45

220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 380 / 400 / 415 380 / 400 / 415 380 / 400 / 415 380 / 400 / 41516 20 20 25 30 16 16 16 16 162.5 2.5 2.5 4 6 2.5 2.5 2.5 2.5 2.56.10 / 5.85 / 5.60 7.70 / 7.40 / 7.10 8.90 / 8.60 / 8.30 11.0 / 10.6 / 10.3 16.6 / 15.9 / 15.3 20.1 / 19.3 / 18.6 2.75 / 2.65 / 2.60 3.68 / 3.53 / 3.43 5.52 / 5.29 / 5.12 6.69 / 6.42 / 6.186.85 / 6.55 / 6.25 8.70 / 8.40 / 8.10 9.90 / 9.50 / 9.20 11.6 / 11.2 / 10.7 16.3 / 15.8 / 15.1 19.9 / 19.1 / 18.4 3.10 / 3.00 / 2.90 3.86 / 3.70 / 3.58 5.44 / 5.26 / 5.05 6.64 / 6.35 / 6.151,800 / 2,100 3,600 / 3,600 3,600 / 3,600 6,600 / 5,700 7,800 / 6,600 8,100 / 7,200 3,600 / 3,600 6,600 / 5,700 7,800 / 6,600 8,100 / 7,20046 / 50 48 / 50 48 / 50 52 / 52 53 / 53 54 / 55 48 / 50 52 / 52 53 / 53 54 / 5565 / 69 65 / 67 65 / 67 69 / 69 70 / 70 71 / 71 65 / 67 69 / 69 70 / 70 71 / 71569 x 790 x 285 996 x 940 x 340 996 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 340 996 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 34042 68 69 98 98 98 71 98 98 981/4 (6.35) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)1/2 (12.7) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)1.65 2 2.35 3.4 3.4 3.4 2.35 3.4 3.4 3.430 30 30 30 30 30 30 30 30 305 / 40 5 / 50 5 / 50 5 / 75 5 / 75 5 / 75 5 / 50 5 / 75 5 / 75 5 / 7530 30 30 30 30 30 30 30 30 3020 50 50 50 50 50 50 50 50 50-15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46-20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24

Energy saving

Down to

-15°C incooling mode

OUTDOORTEMPERATURE

Down to

-20°C inheating mode

OUTDOORTEMPERATURE

Easycontrolby BMS

CONNECTIVITY

Possibleto use on

R22 pipings

R22 RENEWAL

5 yearcompressorwarranty

6.40 A++SEER

SEASONAL ENERGY EFFICIENCY RATIO

4.00 A+SCOP

SEASONAL COEFFICIENT OF PERFORMANCE

INTERNET CONTROL READY: Optional. ESEER and SCOP: For KIT-71PF1E5A. 5 YEARS COMPRESSOR WARRANTY: Only for PRO partners.

U-60PE1E5A U-71PE1E5A U-71PE1E8A

U-100PE1E5A U-125PE1E5A U-140PE1E5A

U-100PE1E8A U-125PE1E8A U-140PE1E8A

U-50PE1E5

Air Outlet Plenum (without regulation adaptor) Air Inlet PlenumDiameters Model Diameters Model

60 & 71 3 x Ø 200 CZ-90DAF2 60 & 71 2 x Ø 250 CZ-DUMPA90MF2100, 125 & 140 4 x Ø 200 CZ-160DAF2 100, 125 & 140 4 x Ø 200 CZ-DUMPA160MF2

InternetControlReady

INTERNET CONTROL

OPTIONAL

Compatible with all Panasonic connectivity solutions. For detailed information go to the VRF Control Systems section.

Optional ControllerTimer remote controllerCZ-RTC2

Optional ControllerWired remote controllerCZ-RTC3

Optional Controller Simplified remote controllerCZ-RE2C2

Optional Controller Wireless remote controllerCZ-RWSK2 + CZ-RWSC3

level of the units shows the value measured of a position 1 meter in front of the main body and 1.5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 7) When installing the outdoor unit at a higher position than the indoor unit. // Recommended fuse for the indoor 3A. // * Available from May 2014.For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu

HIGH

HEATING

CAPACITY

AT -7°C

147

COMMERCIAL PACi ELITE / STANDARDNEW

STANDARD

STANDARD

Single Phase Three Phase6.0 kW 7.1 kW 10.0 kW 12.5 kW 10.0 kW 12.5 kW 14.0 kW

KIT KIT-60PTY2E5A* KIT-71PTY2E5A* KIT-100PTY2E5A* KIT-125PTY2E5A* KIT-100PTY2E8A* KIT-125PTY2E8A* KIP-140PTY2E8A*Indoor S-60PT2E5A S-71PT2E5A S-100PT2E5A S-125PT2E5A S-100PT2E5A S-125PT2E5A S-140PT2E5AOutdoor U-60PEY1E5 U-71PEY1E5 U-100PEY1E5 U-125PEY1E5 U-100PEY1E8 U-125PEY1E8 U-140PEY1E8Timer remote controller CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2Cooling capacity Nominal (Min - Max) kW 6.0 (2.0 - 7.0) 7.1 (2.2 - 7.7) 10.0 (2.7 - 11.5) 12.5 (3.8 - 13.5) 10.0 (2.7 - 11.5) 12.5 (3.8 - 13.5) 14.0 (3.3 - 15.0)ESEER Nominal (Min - Max) W/W 6.7 i 6.1 i 6.1 i 3.66 1) 6.0 h 3.66 1) 3.80 1)

Pdesign kW 6.0 7.1 10.0 — 10.0 — —Power input cooling Nominal (Min - Max) kW 1.660 (0.325 - 2.500) 2.210 (0.325 - 2.820) 3.320 (0.530 - 4.340) 4.150 (0.900 - 5.160) 3.320 (0.530 - 4.340) 4.150 (0.900 - 5.160) 4.700 (0.840 - 5.700)Annual energy consumption (ErP) 2) kWh/a 314 408 574 — 584 — —Heating capacity Nominal (Min - Max) kW 6.0 (1.8 - 7.0) 7.1 (1.8 - 8.1) 10.0 (2.1 - 13.8) 12.5 (3.4 - 15.0) 10.0 (2.1 - 13.8) 12.5 (3.4 - 15.0) 14.0 (4.1 - 16.0)Heating capacity at -7°C 3) Nominal kW 4.39 4.32 7.22 9.14 7.22 9.14 11.68Heating capacity at -15°C 3) Nominal kW — — — — — — —SCOP Nominal (Min - Max) W/W 4.0 h 4.0 h 3.9 a 3.40 4) 3.9 a 3.40 4) 3.52 4)

Pdesign at -10°C kW 6.0 6.0 10.0 — 10.0 — —Power input heating Nominal (Min - Max) kW 1.430 (0.275 - 2.155) 1.820 (0.275 - 2.510) 2.600 (0.410 - 4.000) 3.250 (0.730 - 4.400) 2.600 (0.410 - 4.000) 3.250 (0.730 - 4.400) 3.610 ( 0.900 - 5.210)Annual energy consumption (ErP) 2) kWh/a 2,100 2,100 3,590 3,590 —Indoor unit Air volume Cooling (Hi / Med / Lo) m³/h 1,200 / 1,020 / 870 1,260 / 1,080 / 930 1,800 / 1,500 / 1,380 2,040 / 1,680 / 1,440 1,800 / 1,500 / 1,380 2,040 / 1,680 / 1,440 2,100 / 1,740 / 1,500

Heating (Hi / Med / Lo) 1,200 / 1,020 / 870 1,260 / 1,080 / 930 1,800 / 1,500 / 1,380 2,040 / 1,680 / 1,440 1,800 / 1,500 / 1,380 2,040 / 1,680 / 1,440 2,100 / 1,740 / 1,500Moisture removal volume l/h 3.4 4.2 6.0 7.9 6.0 7.9 9.0Sound pressure level 5) Cooling (Hi / Med / Lo) dB(A) 38 / 34 / 30 39 / 35 / 31 42 / 37 / 35 46 / 40 / 36 42 / 37 / 35 46 / 40 / 36 47 / 41 / 37

Heating (Hi / Med / Lo) dB(A) 38 / 34 / 30 39 / 35 / 31 42 / 37 / 35 46 / 40 / 36 42 / 37 / 35 46 / 40 / 36 47 / 41 / 37Sound power level Cooling (Hi / Med / Lo) dB 56 /52 / 48 57 / 53 / 49 60 / 55 / 53 64 / 58 / 54 60 / 55 / 53 64 / 58 / 54 65 / 59 / 55

Heating (Hi / Med / Lo) dB 56 /52 / 48 57 / 53 / 49 60 / 55 / 53 64 / 58 / 54 60 / 55 / 53 64 / 58 / 54 65 / 59 / 55Dimensions H x W x D mm 235 x 1,275 x 690 235 x 1,275 x 690 235 x 1,590 x 690 230 x 1,590 x 690 235 x 1,590 x 690 230 x 1,590 x 690 360 x 1,655 x 820Net weight kg 33 33 40 40 40 40 40Outdoor unitPower source V 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 380 / 400 / 415 380 / 400 / 415 380 / 400 / 415Recommended fuse A 20 20 25 30 16 16 16Connection mm² 2.5 2.5 4 6 2.5 2.5 2.5Current Cooling A 8.05 / 7.70 / 7.40 10.8 / 10.3 / 9.85 15.6 / 15.0 / 14.4 19.7 / 18.9 / 18.1 5.30 / 5.05 / 4.85 6.50 / 6.20 / 6.00 7.40 / 7.00 / 6.80

Heating A 6.90 / 6.60 / 6.30 8.75 / 8.35 / 8.00 11.9 / 11.5 / 11.1 15.2 / 14.6 / 13.9 4.10 / 3.90 / 3.75 5.10 / 4.80 / 4.65 5.65 / 5.35 / 5.15Air volume Cooling / Heating m³/h 1,800 / 2,100 2,340 / 2,340 4,560 / 4,020 4,800 / 4,380 4,560 / 4,020 4,800 / 4,380 8,100 / 7,200Sound pressure level Cooling / Heating (Hi) dB(A) 46 / 50 50 / 52 54 / 54 56 / 56 54 / 54 56 / 56 54 / 53Sound power level Cooling / Heating (Hi) dB 65 / 69 70 / 70 70 / 70 73 / 73 70 / 70 73 / 73 71 / 70Dimensions H x W x D mm 569 x 790 x 285 569 x 790 x 285 996 x 940 x 340 996 x 940 x 340 996 x 940 x 340 996 x 940 x 340 1,416 x 940 x 340Net weight kg 42 42 73 85 73 85 98Piping connections Liquid pipe Inch (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)

Gas pipe Inch (mm) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)Refrigerant loading R410A kg 1.70 1.70 2.60 3.20 2.60 3.20 3.40Elevation difference (in/out) 6) Max m 30 30 30 30 30 30 30Piping length Min / Max m 5 / 50 5 / 50 5 / 50 5 / 50 5 / 50 5 / 50 5 / 50Precharge length Max m 20 20 30 30 30 30 30Additional charge g/m 40 40 50 50 50 50 50Operating range Cooling Min / Max °C -10 / +43 -10 / +43 -10 / +43 -10 / +43 -10 / +43 -10 / +43 -10 / +43

Heating Min / Max °C -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24

Energy saving

Easycontrolby BMS

CONNECTIVITY

Possibleto use on

R22 pipings

R22 RENEWAL

5 yearcompressorwarranty

6.10 A++SEER

SEASONAL ENERGY EFFICIENCY RATIO

3.90 ASCOP

SEASONAL COEFFICIENT OF PERFORMANCE

INTERNET CONTROL READY: Optional. ESEER and SCOP: For KIT-100PTY2E5A. 5 YEARS COMPRESSOR WARRANTY: Only for PRO partners.

Down to

-10°C incooling mode

OUTDOORTEMPERATURE

Down to

-15°C inheating mode

OUTDOORTEMPERATURE

U-60PEY1E5 U-71PEY1E5

U-100PEY1E5 U-125PEY1E5

U-100PEY1E8 U-125PEY1E8

U-140PEY1E8

InternetControlReady

INTERNET CONTROL

OPTIONAL

CEILINGPACi STANDARD AND ELITE INVERTER+

This range of ceiling mounted units feature a DC fan motor for increased efficiency and reduced operating sound levels. All the units are the same height and depth for a uniform appearance in mixed installations. A knock out is provided to allow for supplementary fresh air for improved air quality.

Technical Focus· Fresh air connection possible (Outside intake duct connection port of 100mm diameter is available on the unit)· All units just 235 mm high· Twin rotary compressor dramatically reduces vibration and noise during operation· DC inverter control· Large and wide air distribution· Industry-leading low sound levels· Twin, Triple and Double-twin split options· Easy connection and control of external fan or ERV using the connector PAW-FDC on the indoor unit PCB. The

external device can be control by the remote control of the Panasonic indoor unit

Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb). // Specifications subject to change without notice.1) ESEER is calculated in base Eurovent IPLV for SBEM for U1 indoor unit SEER=a(EER25)+b(EER50)+c(EER75)+d(EER100) where EER25, EER50, EER75 and EER100 are the EER measured value at 25%, 50%, 75% and 100% part load for temperatures 20, 25, 30 and 35°C DB, respectively. a, b, c and d are values assigned for an office type. These values are given as a=0.2, b=0.36, c=0.32 and d=0.03. The internal temperatures are taken at 27°C DB and 19°C WB. 2) The annual consumption(ErP) is calculated by formula determined by ErP regulation. 3) Heating capacity is calculated including defrost factor correction. 4) SCOP is calculated in base Eurovent IPLV for SBEM with U1 indoor unit including defrost correction factor. 5) The Sound pressure level of the units shows the value measured of a position

148

ELITE

ELITE

Single Phase Three Phase5.0 kW 6.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kWKIT-50PT2E5A* KIT-60PT2E5A* KIT-71PT2E5A* KIT-100PT2E5A* KIT-125PT2E5A* KIT-140PT2E5A* KIT-71PT2E8A* KIT-100PT2E8A* KIT-125PT2E8A* KIT-140PT2E8A*S-50PT2E5A S-60PT2E5A S-71PT2E5A S-100PT2E5A S-125PT2E5A S-140PT2E5A S-71PT2E5A S-100PT2E5A S-125PT2E5A S-140PT2E5AU-50PE1E5 U-60PE1E5A U-71PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5A U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8ACZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC25.0 (1.5 - 5.6) 6.0 (2.5 - 7.1) 7.1 (2.5 - 8.0) 10.0 (3.3 - 12.5) 12.5 (3.3 - 14.0) 14.0 (3.3 - 15.0) 7.1 (2.5 - 8.0) 10.0 (3.3 - 12.5) 12.5 (3.3 - 14.0) 14.0 (3.3 - 15.0)

6.4 i 6.8 i 6.2 i 6.7 i 4.26 1) 3.84 1) 5.9 h 6.6 i 4.26 1) 3.84 1)

5.0 6.0 7.1 10.0 — — 7.1 10.0 — —1.380 (0.260 - 2.050) 1.490 (0.450 - 2.010) 1.930 (0.450 - 2.780) 2.530 (0.840 - 3.850) 3.730 (0.840 - 4.860) 4.650 (0.840 - 5.650) 1.930 (0.450 - 2.780) 2.530 (0.840 - 3.850) 3.730 (0.840 - 4.860) 4.650 (0.840 - 5.650)273 309 965 523 — — 421 531 — —5.6 (1.5 - 6.5) 7.0 (2.0 - 8.0) 8.0 (2.0 - 9.0) 11.2 (4.1 - 14.0) 14.0 (4.1 - 16.0) 16.0 (4.1 - 18.0) 8.0 (2.0 - 9.0) 11.2 (4.1 - 14.0) 14.0 (4.1 - 16.0) 16.0 (4.1 - 18.0)3.62 5.85 6.69 9.63 11.80 13.98 6.69 9.63 11.80 13.983.08 5.74 6.80 9.05 10.84 11.42 6.80 9.05 10.84 11.42

4.0 a 4.1 h 4.0 h 4.3 h 3.63 4) 3.41 4) 4.0 h 4.3 h 3.63 4) 3.41 4)

4.0 6.0 7.1 10.0 — — 7.1 10.0 — —1.410 (0.220 - 2.300) 1.740 (0.400 - 2.480) 1.930 (0.400 - 2.900) 2.600 (0.900 - 4.400) 3.510 (0.900 - 5.210) 4.360 (0.900 - 5.930) 1.930 ( 0.400 - 2.900) 2.600 (0.900 - 4.400) 3.510 (0.900 - 5.210) 4.360 (0.900 - 5.930)1,400 2,049 2,485 3,256 — — 2,485 3,256 — —

900 / 750 / 630 1,200 / 1,020 / 870 1,260 / 1,080 / 930 1,800 / 1,500 / 1,380 2,040 / 1,680 / 1,440 2,100 / 1,740 / 1,500 1,260 / 1,080 / 930 1,800 / 1,500 / 1,380 2,040 / 1,680 / 1,440 2,100 / 1,740 / 1,500900 / 750 / 630 1,200 / 1,020 / 870 1,260 / 1,080 / 930 1,800 / 1,500 / 1,380 2,040 / 1,680 / 1,440 2,100 / 1,740 / 1,500 1,260 / 1,080 / 930 1,800 / 1,500 / 1,380 2,040 / 1,680 / 1,440 2,100 / 1,740 / 1,5002.8 3.4 4.2 6.0 7.9 9.0 4.2 6.0 7.9 9.037 / 33 / 29 38 / 34 / 30 39 / 35 / 31 42 / 37 / 35 46 / 40 / 36 47 / 41 / 37 39 / 35 / 31 42 / 37 / 35 46 / 40 / 36 47 / 41 / 3737 / 33 / 29 38 / 34 / 30 39 / 35 / 31 42 / 37 / 35 46 / 40 / 36 47 / 41 / 37 39 / 35 / 31 42 / 37 / 35 46 / 40 / 36 47 / 41 / 3755 / 51 / 47 56 /52 / 48 57 / 53 / 49 60 / 55 / 53 64 / 58 / 54 65 / 59 / 55 57 / 53 / 49 60 / 55 / 53 64 / 58 / 54 65 / 59 / 5555 / 51 / 47 56 /52 / 48 57 / 53 / 49 60 / 55 / 53 64 / 58 / 54 65 / 59 / 55 57 / 53 / 49 60 / 55 / 53 64 / 58 / 54 65 / 59 / 55235 x 960 x 690 235 x 1,275 x 690 235 x 1,275 x 690 235 x 1,590 x 690 230 x 1,590 x 690 360 x 1,655 x 820 235 x 1,275 x 690 235 x 1,590 x 690 230 x 1,590 x 690 360 x 1,655 x 82027 33 33 40 40 40 33 40 40 40

220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 380 / 400 / 415 380 / 400 / 415 380 / 400 / 415 380 / 400 / 41516 20 20 25 30 16 16 16 16 162.5 2.5 2.5 4 6 2.5 2.5 2.5 2.5 2.56.55 / 6.25 / 6.00 7.15 / 6.90 / 6.70 9.00 / 8.70 / 8.40 11.5 / 11.1 / 10.6 17.0 / 16.4 / 15.8 21.2 / 20.5 / 19.8 3.00 / 2.90 / 2.80 3.95 / 3.75 / 3.65 5.85 / 5.55 / 5.35 7.30 / 6.95 / 6.706.70 / 6.40 / 6.15 8.10 / 7.80 / 7.60 8.90 / 8.60 / 8.30 11.8 / 11.4 / 11.0 16.0 / 15.4 / 14.9 19.8 / 19.2 / 18.5 3.00 / 2.90 / 2.80 4.05 / 3.85 / 3.75 5.50 / 5.20 / 5.05 6.85 / 6.50 / 6.251,800 / 2,100 3,600 / 3,600 3,600 / 3,600 6,600 / 5,700 7,800 / 6,600 8,100 / 7,200 3,600 / 3,600 6,600 / 5,700 7,800 / 6,600 8,100 / 7,20046 / 50 48 / 50 48 / 50 52 / 52 53 / 53 54 / 55 48 / 50 52 / 52 53 / 53 54 / 5565 / 69 65 / 67 65 / 67 69 / 69 70 / 70 71 / 71 65 / 67 69 / 69 70 / 70 71 / 71569 x 790 x 285 996 x 940 x 340 996 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 340 996 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 340 1,416 x 940 x 34042 68 69 98 98 98 71 98 98 981/4 (6.35) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)1/2 (12.7) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)1.65 2.00 2.35 3.40 3.40 3.40 2.35 3.40 3.40 3.4030 30 30 30 30 30 30 30 30 305 / 40 5 / 50 5 / 50 5 / 75 5 / 75 5 / 75 5 / 50 5 / 75 5 / 75 5 / 7530 30 30 30 30 30 30 30 30 3020 50 50 50 50 50 50 50 50 50-15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +46-20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24

Energy saving

Down to

-15°C incooling mode

OUTDOORTEMPERATURE

Down to

-20°C inheating mode

OUTDOORTEMPERATURE

Easycontrolby BMS

CONNECTIVITY

Possibleto use on

R22 pipings

R22 RENEWAL

5 yearcompressorwarranty

6.80 A++SEER

SEASONAL ENERGY EFFICIENCY RATIO

4.10 A+SCOP

SEASONAL COEFFICIENT OF PERFORMANCE

INTERNET CONTROL READY: Optional. ESEER and SCOP: For KIT-60PT2E5A. 5 YEARS COMPRESSOR WARRANTY: Only for PRO partners.

U-60PE1E5A U-71PE1E5A U-71PE1E8A

U-100PE1E5A U-125PE1E5A U-140PE1E5A

U-100PE1E8A U-125PE1E8A U-140PE1E8A

U-50PE1E5

InternetControlReady

INTERNET CONTROL

OPTIONAL

Compatible with all Panasonic connectivity solutions. For detailed information go to the VRF Control Systems section.

Optional ControllerTimer remote controllerCZ-RTC2

Optional ControllerWired remote controllerCZ-RTC3

Optional Controller Wireless remote controllerCZ-RWST3

Optional Controller Simplified remote controllerCZ-RE2C2 NEW

1 meter in front of the main body and 1.5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 6) When installing the outdoor unit at a higher position than the indoor unit. // Recommended fuse for the indoor 3A. // * Available from May 2014.For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu

HIGH

HEATING

CAPACITY

AT -7°C

149

COMMERCIAL PACi ELITE / STANDARDNEW

Down to

-20°C inheating mode

OUTDOORTEMPERATURE

Down to

-15°C incooling mode

OUTDOORTEMPERATURE

Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)1) ESEER is calculated in base Eurovent IPLV for SBEM for U1 indoor unit SEER=a(EER25)+b(EER50)+c(EER75)+d(EER100) where EER25, EER50, EER75 and EER100 are the EER measured value at 25%, 50%, 75% and 100% part load for temperatures 20, 25, 30 and 35°C DB, respectively. a, b, c and d are values assigned for an office type. These values are given as a=0.2, b=0.36, c=0.32 and d=0.03. The internal temperatures are taken at 27°C DB and 19°C WB. 2) Heating capacity is calculated including defrost factor correction. 3) SCOP is calculated in base Eurovent IPLV for SBEM with U1 indoor unit including defrost correction factor. 4) The sound pressure Level of the units shows the value measured of a position 1 meter in front of the main body and 1.5 m from the ground. The sound pressure is measured in accordance with Eurovent 6/C/006-97 specification. 5) Add 100 mm for indoor unit or 70 mm for outdoor unit for piping port. 6) When installing the outdoor unit at a higher position than the indoor unit.* Available from November 2014. Tentative data.Specifications subject to change without notice.For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu

Three Phase20,0 kW 25,0 kW 20,0 kW 25,0 kW

KIT KIT-200PE1E8A KIT-250PE1E8 KIT-200PE1E8A KIT-250PE1E8Indoor S-200PE1E8A S-250PE1E8 S-200PE2E5* S-250PE2E5*Outdoor U-200PE1E8 U-250PE1E8 U-200PE1E8 U-250PE1E8Timer remote controller CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2Cooling capacity Nominal (Min - Max) kW 20.0 (6.0 - 22.4) 25.0 (6.0 - 28.0) 19.5 25.0EER Nominal W/W 3.04 3.09 3.04 3.09ESEER 1) W/W 3.29 3.08Power input cooling Nominal kW 7.640 9.550 6.14 8.09Running amperes A 11.8 14.8 — —Heating capacity Nominal (Min - Max) kW 21.8 (6.0 - 22.4) 28.0 (6.0 - 31.5) 22.4 28.0Heating capacity at -7°C 2) Nominal kW 15.53 19.42 15.53 19.42COP Nominal W/W 3.48 3.84 3.48 3.84SCOP 3) W/W 3.11 3.09Power input heating Nominal kW 6.15 8.20 6.44 7.29Running amperes A 9.5 12.6 — —Indoor unitPower source V / ph / Hz 220 / 240 / 1 / 50 220 / 240 / 1 / 50 220 / 230 / 240 / 1 / 50 220 / 230 / 240 / 1 / 50External static pressure at shipment (with booster cable) Pa 216 (235) 216 (235) 50 (140 / 270 available) 50 (140 / 270 available)Air volume Cooling/Heating m³/h 4,320 4,320 3,360 / 3,360 4,320 / 4,320Moisture removal volume Cooling l/h 11.1 13.9 — —Sound pressure level 4) Hi / Med / Lo dB(A) 51 / 50 / 49 51 / 50 / 49 44 / 43 / 41 46 / 45 / 43Sound power level dB(A) 82 82 — —Dimensions H x W x D mm 479 x 1,428 x 1,230 479 x 1,428 x 1,230 479 x 1,453 x 1205 479 x 1,453 x 1205Net weight kg 120 120 105 110Outdoor unitPower source V / ph / Hz 380 / 415 / 3+N / 50/60 380 / 415 / 3+N / 50/60 380 / 415 / 3+N / 50/60 380 / 415 / 3+N / 50/60Recommended fuse A 15 20 15 20Air volume Cooling / Heating m³/h 7,740 7,080 7740 7080Sound pressure level 4) Cooling / Heating (Hi) dB(A) 57 / 57 57 / 58 57 / 57 57 / 58Sound power level (Hi) dB 72 73 72 73Dimensions 5) H x W x D mm 1,526 x 940 x 340 1,526 x 940 x 340 1,526 x 940 x 340 1,526 x 940 x 340Net weight kg 118 128 118 128Piping connections Liquid pipe mm (Inch) 9.52 (3/8) 12.7 (1/2) 9.52 (3/8) 12.7 (1/2)

Gas pipe mm (Inch) 25.4 (1) 25.4 (1) 25.4 (1) 25.4 (1)Refrigerant loading kg 5.3 6.5 5,3 6,5Elevation difference (in/out) 6) Max m 30 30 30 30Piping length Min - Max m 5 - 100 5 - 100 5 - 100 5 - 100Precharge length Max m 30 30 30 30Additional charge g/m 40 80 40 80Operating range Cooling Min / Max °C -15 / +43 -15 / +43 -15 / +43 -15 / +43

Heating Min / Max °C -20 / +15 -20 / +15 -20 / +15 -20 / +15

Panasonic breaks new ground in offering high performance and power in a small space. The 20-25kW from Panasonic is ideally suited for large retail applications and other large areas not needing the higher capacities of VRF systems. The lightweight and compact design enables easier installation in any commercial space. The twin fan system saves valuable footprint compared to traditional 20-25kW systems which are larger and therefore require more space.

Energy saving

Easycontrolby BMS

CONNECTIVITY

Possibleto use on

R22 pipings

R22 RENEWAL

5 yearcompressorwarranty

HIGH STATIC PRESSURE HIDE AWAY 20-25kWBIG PACi INVERTER+

InternetControlReady

INTERNET CONTROL

OPTIONAL

INTERNET CONTROL READY: Optional. 5 YEARS COMPRESSOR WARRANTY: Only for PRO partners.

150

Inspection port (450 x 450mm or more)

U-200PE1E8U-250PE1E8

PlenumsAir Outlet Plenum (suitable for rigid + flexible duct)

N. of exits with diameters ModelS-250PE1E8 1 x 500 mm CZ-TREMIESPW706S-200PE1E8A 1 x 450 mm CZ-TREMIESPW705

KIT-200PE1E8A // KIT-250PE1E8

Technical Focus

· High efficiency inverter system · Cooling with low outdoor temperatures (down to -15°C)· Maximum pipe length 100 m (more than 40% longer than other split systems) · Multifunctional wireless remote control with built-in temperature control· Fresh air supply for improved air quality

Features

ENERGY EFFICIENCY AND ECOLOGY· Maximum efficiency Inverter system· R410A environmentally friendly refrigerant gas

COMFORT· Cooling with low outdoor temperatures (down to -15°C)· Heating with low outdoor temperatures (down to -20°C)· Selection of temperature sensor at indoor unit or wired remote control

EASY OF USE· Weekly On/Off timer (6 settings per day and 42 per week)· Selection of wired / Wireless and simplified wired remote controller

EASY INSTALLATION AND MAINTENANCE· High static pressure units ideal for shops and offices

System exampleAn inspection port (450 x 450 mm or more) is required at the lower side of the indoor unit body. Distributor (field supply).

Compatible with all Panasonic connectivity solutions. For detailed information go to the VRF Control Systems section.

Optional ControllerTimer remote controllerCZ-RTC2

Optional ControllerWired remote controllerCZ-RTC3

Optional Controller Wireless remote controllerCZ-RWSK2 + CZ-RWSC3

Optional Controller Simplified remote controllerCZ-RE2C2

HIGH

HHEATING

CCAPACITY

AT -7°C

151

COMMERCIAL PACi ELITE

PACi Twin, Triple and Double-Twin SystemWith this system, a single outdoor unit can split capacity for up to 4 indoor areas simultaneously. This makes the system particularly apt for common areas. It reduces noise concentration and enables the same temperature to be reached around the room. A mix of indoor units can be installed (wall, cassette, duct, ceiling) in one system.

PACi Standard Single and Twin System from 10.0 to 12.5 kWUp to 2 indoor units connectable on the same outdoor. Panasonic’s PACi units can be installed as single and twin systems. The indoor units can be combined following the selection table. The operation will always be simultaneous. All the indoor units will work with the same settings.

PACi Elite Twin, Triple and Double-Twin System from 7.1 to 14.0 kWUp to 4 indoor units can be connected to the same outdoor unit. Panasonic’s PACi units 71, 100, 125 and 140 can be installed as twin, triple and double-twin systems. The indoor units can be combined as per the selection table. The operation will always be simultaneous. All the indoor units will work with the same settings.

Big PACi Elite Twin, Triple and Double-Twin System from 20.0 to 25.0 kWUp to 4 indoor units can be connected to the same outdoor unit. Panasonic’s PACi units 200 and 250 can be installed as twin, triple and double-twin systems. The indoor units can be combined as per the selection table. The operation will always be simultaneous. All the indoor units will work with the same settings.

152

Indoor unit capacitiesCapacity Wall 4 Way 60x60 Cassette 4 Way 90x90 Cassette Low Static Pressure Hide Away High Static Pressure Hide Away Celling

3.6 kW S-36PK1E5A S-36PY2E5A S-36PU1E5A S-36PN1E5A S-36PF1E5A S-36PT2E5A4.5 kW S-45PK1E5A S-45PY2E5A S-45PU1E5A S-45PN1E5A S-45PF1E5A S-45PT2E5A5.0 kW S-50PK1E5A S-50PY2E5A S-50PU1E5A S-50PN1E5A S-50PF1E5A S-50PT2E5A6.0 kW S-60PK1E5A S-60PU1E5A S-60PN1E5A S-60PF1E5A S-60PT2E5A7.1 kW S-71PK1E5A S-71PU1E5A S-71PN1E5A S-71PF1E5A S-71PT2E5A10.0 kW S-100PK1E5A S-100PU1E5A S-100PN1E5A S-100PF1E5A S-100PT2E5A12.5 kW S-125PU1E5A S-125PN1E5A S-125PF1E5A S-125PT2E5A

Outdoor unit capacitiesCapacity PACi Standard Single and Twin System PACi Elite Twin, Triple and Double-Twin System from 7.1 to 14.0 kW PACi Elite Twin, Triple and Double-Twin System from

20.0 to 25.0 kW

7.1 kW U-71PEY1E5 U-71PE1E5A // U-71PE1E8A10.0 kW U-100PEY1E5 // U-100PEY1E8 U-100PE1E5A // U-100PE1E8A12.5 kW U-125PEY1E5 // U-125PEY1E8 U-125PE1E5A // U-125PE1E8A14.0 kW U-140PEY1E8 U-140PE1E5A // U-140PE1E8A20.0 kW U-200PE1E825.0 kW U-250PE1E8

U-__1E5 Single Phase // U-__1E8 Three Phase

PACi Standard Single/Simultaneous operation system combinationskW OutdoorIndoor 7.1 10.0 12.5 14.03.6 Twin

5.0 Twin

6.0 Twin

7.1 Single¹ Twin

10.0 Single¹

12.5 Single¹

14.0 Single¹

S-50 S-50

U-100

S-100

U-100

S-60 S-60

U-125

S-125

U-125

PACi Elite from 7.1 to 14.0 kW Single/Simultaneous operation system combinationskW OutdoorIndoor 7.1 10.0 12.5 14.03.6 Twin Triple Double-Twin

4.5 Triple

5.0 Twin Triple

6.0 Twin

7.1 Single¹ Twin

10.0 Single¹

12.5 Single¹

14.0 Single¹

1. PACi 1x1 Kit solution.

S-100

U-100

S-71

U-71

S-71

U-71

S-125

U-125

S-140

U-140

S-140

U-140

S-36 S-36

U-71S-36 S-36

U-71

S-50 S-50

U-100

S-36 S-36 S-36

U-100

S-45 S-45 S-45

U-125

S-50 S-50 S-50

U-140

S-60 S-60

U-125

S-36 S-36S-36 S-36

U-125

S-71 S-71

U-140

S-71 S-71

U-140

PACi Elite from 20.0 to 25.0 kW Single/Simultaneous operation system combinationskW OutdoorIndoor 20.0 25.05.0 Double-Twin

6.0 Double-Twin

7.1 Triple

10.0 Twin

12.5 Twin

20.0 Single¹

25.0 Single¹

1. PACi 1x1 Kit solution.

S-200

U-200

S-250

U-250

S-71 S-71 S-71

U-200

S-100 S-100

U-200

S-125 S-125

U-250

S-50 S-50S-50 S-50

U-200

S-60 S-60S-60 S-60

U-250

360ºair flow

153

COMMERCIAL PACi ELITE / STANDARDNEW

DOUBLE-TWIN

TWINSINGLE TRIPLE

H1

L

H1

H2

L2L1

A

H1

H2

L3L1

B

H4

H3

L2

H4

H3

H1

H2

L4L3

C

L

AL1 L2

L6L5

C

H6

H5

H7

L L

PACi Standard Twin SystemJoint distribution (sold separately)A= CZ-P155BK1

PACi Elite Twin, Triple and Double-Twin System from 7.1 to 14.0 kWJoint distribution (sold separately)A= CZ-P155BK1B= CZ-P3HPC2BMC= CZ-P155BK1

PACi Elite Twin, Triple and Double-Twin System from 20.0 to 25.0 kWJoint distribution (sold separately)A = CZ-P680BK2BMB = CZ-P3HPC2BMC = CZ-P155BK1

Twin System PACi Standard Single and Twin System PACi Elite Twin, Triple and Double-Twin System from 7.1 to 25 kWIndoor unit combinations (see examples above)

Equivalent lengths and height differences (m) for outdoor unit sizes...

Indoor unit combinations (see examples above) Equivalent lengths and height differences (m) for outdoor unit sizes from 7.1 to 14.0 kW

Equivalent lengths and height differences (m) for outdoor unit sizes from 20.0 to 25.0 kW

Single Twin Single Twin Triple Double-TwinTotal pipe length L L + L1 + L2 50 m L L + L1 + L2 L + L1 + L2 + L3 L + L1 + L2 + L3 + L4 + L5 + L6 U-60/U-71: 50 m

U-100/125/140: 75 m 100 m

Maximum pipe length from outdoor unit to most distant indoor unit

– – – – L + L1 or L + L2

L + L1 or L + L2 or L + L3 L + L1 + L3 or L + L1 + L4 or L + L2 + L5 or L + L2 + L6

– 100 m

Maximum branch pipe length – L1 L2 15 – L1 or L2 L1 or L2 or L3 L1 + L3 or L1 + L4 or L2 + L5 or L2 + L6

15 m 20 m

Maximum branch pipe length differences

– L1 > L2L1 - L2

10 – L1 > L2:L1 - L2

L1 > L2 > L3: L1 - L2L2 - L3L1 - L3

L2 + L6 (Max.)L1 + L3 (Min.):(L2 + L6) - (L1 + L3)

10 m 10 m

Maximum pipe length after frist branch (Double-Twin)

– – – – – – L2 > L1: L2 - L1 10 m 10 m

Maximum pipe length differences after second branch (Double-Twin)

– – – – – – L4 > L3: L4 - L3L6 > L5: L6 - L5

10 m 10 m

Height difference(outdoor unit located higher)

H1 H1 30 H1 H1 H1 H1 30 m 30 m

Height difference(outdoor unit located lower)

H1 H1 15 H1 H1 H1 H1 15 m 15 m

Height difference between indoor units

– H2 0.5 – H2 H2 or H3 or H4 H2 or H3 or H4 or H5 or H6 0.5 m 0.5 m

Twin System PACi Standard Single and Twin System PACi Elite Twin, Triple and Double-Twin System from 7.1 to 14.0 kW PACi Elite Twin, Triple and Double-Twin System from 20.0 to 25.0 kWOutdoor unit main pipe diameter (L)

Indoor unit connection tube (L1, L2)

Outdoor unit main pipe diameter (L)

Indoor unit connection pipe diameter (L1, L2, L3, L4) (mm) Outdoor unit main pipe diameter (L) (mm)

Double-Twin distribution pipe (L1, L2)¹

Indoor unit connection pipe diameter

Unit type capacity 100 125 50 60 71 - 140 36 45 50 60 71 200 250 100 - 125 50 60 - 125Liquid pipe (mm) Ø 9.52 Ø 12.7 Ø 6.35 Ø 9.52 Ø 9.52 Ø 6.35 Ø 6.35 Ø 6.35 Ø 9.52 Ø 9.52 Ø 9.52 Ø 12.7 Ø 9.52 Ø 6.35 Ø 9.52Gas pipe (mm) Ø 15.88 Ø 15.88 Ø 12.7 Ø 15.88 Ø 15.88 Ø 12.70 Ø 12.70 Ø 12.70 Ø 15.88 Ø 15.88 Ø 25.4 Ø 25.4 Ø 15.88 Ø 12.7 Ø 15.88Additional charge (g/m) 50 50 20 50 50 20 20 20 50 50 40 80 40 20 40

1. Total capacity of indoor unit connected after the branch

Refrigerant charging: For the twin connection, the amount of refrigerant required for pipe length 30 m has been included in this unit at the factory while that required for pipe length 20 m has been included for the Triple / Double-Twin connections.No additional charge is required for the first 30 m pipe length in the case of the twin connection and for the first 20 m in the case of the Triple / Double-Twin connections. The amount of included refrigerant for each model is listed on NAMA PLATE.Make additional charges by adding up pipe length in an order of main (L branch pipe), (L1, L2, L3 wide diameter) and then selecting the amount of refrigerant corresponding to the remaining (after 30 m for the Twin connection and after 20 m for the Triple / Double-Twin connections) liquid side pipe diameter and pipe length from the below table.

154

Compatible Indoor Units 3.6 kW 4.5 kW 5.0 kW 6.0 kW 7.1 kW 10.0 kW 12.5 kWCapacity for all indoor units

Cooling kW 3.6 4.5 5.0 6.0 7.1 10.0 12.5Heating kW 4.2 5.2 5.6 7.0 8.0 11.2 14.0

Wall* S-36PK1E5A S-45PK1E5A S-50PK1E5A S-60PK1E5A S-71PK1E5A S-100PK1E5ADimensions H x W x D mm 300 x 1,065 x 230 300 x 1,065 x 230 300 x 1,065 x 230 300 x 1,065 x 230 300 x 1,065 x 230 300 x 1,065 x 230Sound pressure level Cooling (Hi / Me / Lo) dB(A) 35 / 31 / 27 38 / 34 / 30 40 / 36 / 32 47 / 44 / 40 47 / 44 / 40 47 / 44 / 40

Heating (Hi / Me / Lo) dB(A) 35 / 31 / 27 38 / 34 / 30 40 / 36 / 32 47 / 44 / 40 47 / 44 / 40 47 / 44 / 40Air volume Cooling (Hi / Me / Lo) m³ / h 660 / 570 / 450 720 / 630 / 510 840 / 720 / 630 1,080 / 870 / 690 1,080 / 870 / 690 1,140 / 990 / 780

Heating (Hi / Me / Lo) m³ / h 660 / 570 / 450 720 / 630 / 510 840 / 720 / 630 1,080 / 870 / 690 1,080 / 870 / 690 1,140 / 990 / 780

4 Way 60x60 Cassette** S-36PY2E5A S-45PY2E5A S-50PY2E5APanel CZ-KPY3A CZ-KPY3A CZ-KPY3ADimensions Indoor H x W x D mm 283 x 575 x 575 283 x 575 x 575 283 x 575 x 575

Panel H x W x D mm 30 x 625 x 625 30 x 625 x 625 30 x 625 x 625Sound pressure level Cooling (Hi / Me / Lo) dB(A) 32 / 29 / 26 36 / 32 / 28 41 / 37 / 33

Heating (Hi / Me / Lo) dB(A) 32 / 29 / 26 36 / 32 / 28 41 / 37 / 33Air volume Cooling / Heating m³ / h 540 / 540 636 / 636 750 / 750

4 Way 90x90 Cassette*** S-36PU1E5A S-45PU1E5A S-50PU1E5A S-60PU1E5A S-71PU1E5A S-100PU1E5A S-125PU1E5APanel CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21Dimensions Indoor H x W x D mm 256 x 840 x 840 256 x 840 x 840 256 x 840 x 840 256 x 840 x 840 256 x 840 x 840 319 x 840 x 840 319 x 840 x 840

Panel H x W x D mm 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950Sound pressure level Cooling (Hi / Me / Lo) dB(A) 30 / 28 / 27 31 / 28 / 27 32 / 29 / 27 36 / 31 / 28 37 / 31 / 28 44 / 38 / 32 45 / 39 / 33

Heating (Hi / Me / Lo) dB(A) 30 / 28 / 27 31 / 28 / 27 32 / 29 / 27 36 / 31 / 28 37 / 31 / 28 44 / 38 / 32 45 / 39 / 33Air volume Cooling (Hi / Me / Lo) m³ / h 840 / 780 / 720 900 / 780 / 720 960 / 810 / 720 1,260 / 1,020 / 840 1,320 / 1,020 / 840 1,980 / 1,620 / 1,260 2,100 / 1,680 / 1,320

Heating (Hi / Me / Lo) m³ / h 840 / 780 / 720 900 / 780 / 720 960 / 810 / 720 1,260 / 1,020 / 840 1,320 / 1,020 / 840 1,980 / 1,620 / 1,260 2,100 / 1,680 / 1,320

Low Static Pressure Hide Away*** S-36PN1E5A S-45PN1E5A S-50PN1E5A S-60PN1E5A S-71PN1E5A S-100PN1E5A S-125PN1E5ADimensions H x W x D mm 250 x 780(+100) x 650 250 x 780(+100) x 650 250 x 780(+100) x 650 250 x 1,000(+100) x 650 250 x 1,000(+100) x 650 250 x 1,200(+100) x 650 250 x 1,200(+100) x 650Sound pressure level Cooling (Hi / Me / Lo) dB(A) 40 / 38 / 35 41 / 39 / 35 41 / 39 / 35 43 / 41 / 36 43 / 41 / 36 44 / 42 / 37 46 / 44 / 39

Heating (Hi / Me / Lo) dB(A) 40 / 38 / 35 41 / 39 / 35 41 / 39 / 35 43 / 41 / 36 43 / 41 / 36 44 / 42 / 37 46 / 44 / 39External static pressure High / Medium / Low Pa 80 / 50 / 10 80 / 50 / 10 80 / 50 / 10 80 / 50 / 10 80 / 50 / 10 80 / 50 / 10 80 / 50 / 10Air volume Cooling / Heating m³ / h 840 / 840 960 / 960 960 / 960 1,320 / 1,320 1,320 / 1,320 2,160 / 2,160 2,400 / 2,400

Hide Away High Static Pressure*** S-36PF1E5A S-45PF1E5A S-50PF1E5A S-60PF1E5A S-71PF1E5A S-100PF1E5A S-125PF1E5ADimensions H x W x D mm 290 x 800 x 700 290 x 800 x 700 290 x 800 x 700 290 x 1,000 x 700 290 x 1,000 x 700 290 x 1,400 x 700 290 x 1,400 x 700Sound pressure level Cooling (Hi / Me / Lo) dB(A) 33 / 29 / 25 34 / 30 / 26 34 / 30 / 26 35 / 32 / 26 35 / 32 / 26 38 / 34 / 31 39 / 35 / 32

Heating (Hi / Me / Lo) dB(A) 33 / 29 / 25 34 / 30 / 26 34 / 30 / 26 35 / 32 / 26 35 / 32 / 26 38 / 34 / 31 39 / 35 / 32External static pressure High / Medium / Low Pa 150 / 70 / 10 150 / 70 / 10 150 / 70 / 10 150 / 70 / 10 150 / 70 / 10 150 / 100 / 10 150 / 100 / 10Air volume Cooling (Hi / Me / Lo) m³ / h 840 / 780 / 600 840 / 780 / 600 960 / 900 / 720 1,260 / 1,140 / 900 1,260 / 1,140 / 900 1,920 / 1,560 / 1,260 2,040 / 1,740 / 1,380

Heating (Hi / Me / Lo) m³ / h 840 / 780 / 600 840 / 780 / 600 960 / 900 / 720 1,260 / 1,140 / 900 1,260 / 1,140 / 900 1,920 / 1,560 / 1,260 2,040 / 1,740 / 1,380

Ceiling*** S-36PT2E5A S-45PT2E5A S-50PT2E5A S-60PT2E5A S-71PT2E5A S-100PT2E5A S-125PT2E5ADimensions H x W x D mm 210 x 910 x 680 210 x 910 x 680 235 x 960 x 690 235 x 1,275 x 690 235 x 1,275 x 690 235 x 1,590 x 690 230 x 1,590 x 690Sound pressure level Cooling (Hi / Me / Lo) dB(A) 35 / 32 / 30 38 / 33 / 30 38 / 33 / 30 39 / 36 / 33 39 / 36 / 33 42 / 38 / 35 45 / 40 / 37

Heating (Hi / Me / Lo) dB(A) 36 / 32 / 30 39 / 34 / 30 39 / 34 / 30 40 / 36 / 33 40 / 36 / 33 42 / 38 / 35 46 / 41 / 38Air volume Cooling (Hi / Me / Lo) m³ / h 840 / 720 / 630 900 / 750 / 630 900 / 750 / 630 1,200 / 1,020 / 870 1,260 / 1,080 / 930 1,800 / 1,500 / 1,380 2,040 / 1,680 / 1,440

Heating (Hi / Me / Lo) m³ / h 840 / 720 / 630 900 / 750 / 630 900 / 750 / 630 1,200 / 1,020 / 870 1,260 / 1,080 / 930 1,800 / 1,500 / 1,380 2,040 / 1,680 / 1,440

* Available from June 2014. ** Available from November 2014. *** Available from May 2014.

Compatible Outdoor Units 7.1 kW 10.0 kW 12.5 kW 14.0 kW 7.1 kW 10.0 kW 12.5 kW 14.0 kW 20.0 kW 25.0 kWOutdoor Single Phase U-71PEY1E5 U-100PEY1E5 U-125PEY1E5 — U-71PE1E5A U-100PE1E5A U-125PE1E5A U-140PE1E5AOutdoor Three Phase — U-100PEY1E8 U-125PEY1E8 U-140PEY1E8 U-71PE1E8A U-100PE1E8A U-125PE1E8A U-140PE1E8A U-200PE1E8 U-250PE1E8Cooling capacity Nominal (Min - Max) kW 7.1 (2.0 - 7.7) 10.0 (2.7 - 11.5) 12.5 (3.8 - 13.5) 14.0 (3.3 - 15.5) 7.1 (2.5 - 8.0) 10.0 (3.3 - 12.5) 12.5 (3.3 - 14.0) 14.0 (3.3 - 15.5) 20.0 (6.0 - 22.4) 25.0 (6.0 - 28.0)Heating capacity Nominal (Min - Max) kW 7.1 (1.8 - 8.1) 10.0 (2.1 - 13.8) 12.5 (3.4 - 15.0) 14.0 (4.1 - 16.0) 8.0 (2.0 - 9.0) 11.2 (4.1 - 14.0) 14.0 (4.1 - 16.0) 16.0 (4.1 - 18.0) 21.8 (6.0 - 22.4) 28.0 (6.0 - 31.5)Power source Single Phase V 220 / 230 / 240 220 / 230 / 240 220 / 230 / 240 — 220 / 240 220 / 240 220 / 240 220 / 240

Three Phase V — 380 / 400 / 415 380 / 400 / 415 380 / 415 380 / 415 380 / 415 380 / 415 380 / 415 380 / 415 380 / 415Connection mm² 2.50 4.00 6.00 2.50 2 x 1.5 or 2.5 2 x 1.5 or 2.5 2 x 1.5 or 2.5 2 x 1.5 or 2.5 — —Air volume Cooling / Heating m³/h 2,340 4,560 / 4,020 4,800 / 4,380 8,100 / 7,200 3,600 / 3,600 6,600 / 5,700 7,800 / 6,600 8,100 / 7,200 7740 7080Sound pressure level Cooling / Heating (Hi) dB(A) 50 / 52 54 / 54 56 / 56 54 / 53 48 / 50 52 / 52 53 / 53 54 / 55 57 / 57 57 / 58Sound power level Cooling / Heating (Hi) dB 70 / 70 70 / 70 73 / 73 71 / 70 65 / 67 69 / 69 70 / 70 71 / 71 72 73Dimensions H x W x D mm 569x790x285 996x940x340 996x940x340 1,416x940x340 996x940x340 1,416x940x340 1,416x940x340 1,416x940x340 1526x940x340 1526x940x340Net weight kg 42 73 85 98 69 98 98 98 118 128Piping connections Liquid pipe Inch (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 9.52 (3/8) 12.7 (1/2)

Gas pipe Inch (mm) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 25.4 (1) 25.4 (1)Refrigerant Loading R410A kg 1.7 2.60 3.20 3.4 2.35 3.4 3.4 3.4 5.3 6.5Elevation difference (in/out) Max m 30 30 30 30 30 30 30 30 30 30Piping length Min / Max m 5 / 50 5 / 50 5 / 50 5 / 50 5 / 50 5 / 75 5 / 75 5 / 75 5 / 100 5 / 100Operating range Cooling Min / Max °C -10 / +43 -10 / +43 -10 / +43 -10 / +43 -15 / +46 -15 / +46 -15 / +46 -15 / +46 -15 / +43 -15 / +43

Heating Min / Max °C -15 / +24 -15 / +24 -15 / +24 -15 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +24 -20 / +15 -20 / +15

Compatible with all Panasonic connectivity solutions. For detailed information go to the VRF Control Systems section.

Optional ControllerTimer remote controllerCZ-RTC2

Optional ControllerWired remote controllerCZ-RTC3

Optional Controller Wireless remote controllerVarious type.

Optional Controller Simplified remote controllerCZ-RE2C2

155

COMMERCIAL PACi ELITE / STANDARDNEW

Air Curtain with DX Coil, connected to the PACi or VRF SystemsThe Panasonic range of air curtains is designed for smooth operation and efficient performance. Air curtains produce a continuous stream of air blown from the top to the bottom of an open doorway and create a barrier that people and products can flow across, but air can’t. Designed to improve energy efficiency, minimise heat loss from a building, and to allow retailers to keep doors open to encourage customers, our Air Curtains are suitable for connection to both PACi and VRF Systems.

· Super-efficient with new EC fan motor (40% lower running costs compared to a standard AC fan motor)

· Easy Cleaning and Servicing· Can be connected to either Panasonic PACi or VRF systems· Built-in drain for cooling operation· Standard and Jet Flow air curtains can be controlled via Panasonic’s range of remote

internet controlsThe new standard and jet-flow models are ideal for connection to a PACi or ECOi system. With simple ‘plug and play’ installation, both are fitted with an EC fan motor for a smooth operation and efficient performance. This new fan guarantees 40% lower running cost than with a standard AC fan motor. With air curtains often running for 12 hours a day as a minimum, this can lead to considerable savings.

Highly effi cient heating effectThe combined air stream, which has a desirable low air current induction factor (mixing factor), can carry the selected initial temperature effect over long distances, and will reach the floor area while still at room temperature. This is necessary to avoid cooling down the interior spaces.Available in different lengths to suit requirements between 1 and 2,5m, both air curtains have outlet grilles that can be adjusted to five different positions. The jet flow model can be installed up to a height of 3,5m with the standard model up to 3,0m. The outlet grilles can be easily adjusted into five positions to suit different installations requirements and the air filter can be accessed without the need for specialist tools.

100

80

60

40

20

0

Heating capacity comparison: Electrical Air curtain / Panasonic Air Curtain

ELECTRIC AIR CURTAIN

PANASONICAIR CURTAIN

80%*

MORE EFFICIENT

* With the U-100PE1E5 on the PAW-20PAIRC-MS.Calculation method: Taking as consideration SCOP of the Panasonic combination of 6.0. If 100 is the energy needed for a air curtain, Panasonic Air curtain will need 1/(1-6)*100=20.

156

How does it work?Stale air from the room is taken in and ejected near the door. This creates a ‘roll of air’ that shields the door area, mixing with the colder incoming air. It then turns away from the door, back into the room and toward the intake screen, where it is partly drawn in again. This flow of air helps to create a barrier for heat loss yet at the same time refreshes room air.

0,0 m / 34°C

0,5 m / 30°C

1,0 m / 26°C

1,5 m / 23°C

2,0 m / 21°C

2,5 m / 20°C

100 mmHeight / Temperature

Supply air exit

Open air

Air curtain

Induction open air

Induction inside air

For a optimum efficiency, Air flow velocity at 15cm from the floor should be 1,5 to 2.0 m/s

Floor

Inside air

Intelligent Operation Our air curtains combine air flow and heating / cooling technology to ensure optimum comfort and energy efficiency whilst also creating an effective barrier between indoor and outdoor environments. Design and installation is key to achieving the correct height / temperature settings to achieve optimum performance. Our air curtains are designed to answer the demands of the retail, commercial and industrial markets.

0 m/s

0.5 m/s

5.0 m/s

2.0 m/sIdeal air flow:1.5-2 m/s at 15cm from the floor

4

3

2

1

Internet ControlAn app added to your tablet or smartphone or via the Internet allows you to control and manage the system remotely. There is also the option to integrate into existing BMS systems by using other Panasonic interfaces.

Optimised air flow velocity1. Energy losses, no air curtain installed2. Too low velocity air curtain – Air Curtain not efficient3. Optimum results with the Tekadoor Air Curtain connected to Panasonic PACi4. Too high velocity air curtain – considerable turbulence, energy lost to the outside, Air Curtain not efficient

157

COMMERCIAL

Easycontrolby BMS

CONNECTIVITY

High efficiency Air curtain connected to your PACi installation on 1x1 connection!Plug & Play Installation EC Fan motor for a smooth operation and efficient performance.2 types of Air flow available: Jet-Flow and Standard.2015 Fan Standard available today.Easy Cleaning and Servicing.

AIR CURTAIN WITH DX COIL

MAX INSTALLATION HIGHJet-Flow: 3.5 mStandard flow: 3.0 m

HP 4 HP 8 HP 10 HP 4 HP 10 HPAir Curtain PAW-10PAIRC-MJ PAW-15PAIRC-MJ PAW-20PAIRC-MJ PAW-10PAIRC-MS PAW-20PAIRC-MSAir flow type Jet-flow StandardAir Flow Length (A) m 1.0 1.5 2.0 1.0 2.0Air volume High m²/h 1,800 2,700 3,600 1,800 2,700

Medium m²/h 1,500 2,300 3,000 1,500 2,300Low m²/h 1,200 1,900 2,500 1,200 1,900

Cooling capacity nominal¹ kW 9.2 17.5 23.1 9.2 17.5Heating capacity with air in 20°C, air out 40°C kW 11.9 17.9 23.9 11.9 17.9Heating capacity with air in 20°C, air out 35°C kW 8.9 13.4 17.9 8.9 13.4Heating capacity with air in 20°C, air out 30°C kW 5.9 8.9 11.9 5.9 8.9Max installation height Good condition m 3.5 3.5 3.5 3.0 3.0

Normal condition m 3.1 3.1 3.1 2.7 2.7Bad condition m 2.7 2.7 2.7 2.4 2.4

Refrigerant R410A R410A R410A R410A R410ALiquid pipe Inch (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)Gas pipe Inch (mm) 5/8 (15.88) 3/4 (19.05) 7/8 (22.22) 5/8 (15.88) 7/8 (22.22)Fan 230V / 50Hz / 1 / N / PE 230V / 50Hz / 1 / N / PE 230V / 50Hz / 1 / N / PE 230V / 50Hz / 1 / N / PE 230V / 50Hz / 1 / N / PEFan type EC EC EC EC ECCurrency High A 2.1 2.8 4.2 2.1 4.2

Med A 0.8 1.1 1.6 0.8 1.6Low A 0.3 0.4 0.6 0.3 0.6

Electrical Consumption High kW 0.44 0.59 0.89 0.44 0.89Med kW 0.17 0.23 0.34 0.17 0.34Low kW 0.06 0.08 0.12 0.06 0.12

Protecting Fuse A M16A M16A M16A M16A M16ANoise dB(A) 40-55 40-56 40-57 40-55 40-57Dimensions W x H x D mm 1,210 x 260 x 590 1,710 x 260 x 590 2,210 x 260 x 590 1,210 x 260 x 490 2,210 x 260 x 490Weight kg 70 100 138 60 128

Outdoor combination with PACi Elite unit 40°C U-100PE1E5/8 U-140PE1E5/8 U-200PE1E8 U-100PE1E5/8 U-140PE1E5/8Outdoor combination with PACi Standard unit 40°C U-100PEY1E5/8 — — U-100PEY1E5/8 —Outdoor combination with PACi Elite unit 35°C U-71PE1E5/8 U-100PE1E5/8 U-140PE1E5/8 U-71PE1E5/8 U-100PE1E5/8Outdoor combination with PACi Standard unit 35°C U-100PEY1E5/8 U-100PEY1E5/8 — U-100PEY1E5/8 U-100PEY1E5/8Outdoor combination with PACi Elite unit 30°C U-50PE1E5 U-100PE1E5/8 U-100PE1E5/8 U-50PE1E5 U-100PE1E5/8Outdoor combination with PACi Standard unit 30°C U-60PEY1E5 U-100PEY1E5/8 U-100PEY1E5/8 U-60PEY1E5 U-100PEY1E5/8

All combinations under rated conditions: Heating Outdoor +7°C DB/+6°C WB Indoor +20°C DB. In case of lower outdoor temperatures a higher capacity outdoor unit model may be necessary .1) Rated Conditions Cooling Outdoor +35°C DB Indoor +27°C DB/+19°C WB, Discharge temperature ³ 16°C.

158

A

560

260

45

295

100

4575

60100

30

30

105 105A+210

85

120

A

460

260

45

35 295

25

70

100

4575

60100

30

30

105 105A+210

TOP VIEW TOP VIEW

BOTTOM VIEW

FRONT VIEW FRONT VIEW

BOTTOM VIEW

SIDE VIEW

SECTION SECTION

SIDE VIEW

Pressure lineIntake line

Rivetting nut M8 Rivetting nut M8

Pressure lineIntake line

STANDARD DIMENSIONSJET-FLOW DIMENSIONS

PAW-10PAIRC-MS PAW-20PAIRC-MSA 1,000 2,000

JET-FLOW: PAW-10PAIRC-MJ // PAW-15PAIRC-MJ //PAW-20PAIRC-MJ

STANDARD: PAW-10PAIRC-MS // PAW-20PAIRC-MS

Technical focus

· Save up to 40% Energy Costs by use of the integrated EC Fan Technology (Higher efficiency than conventional AC fan, softstart and longer motor duration)

· 3 Lengths of Air Curtains Jet-Flow, from 1 to 2 m and 2 lengths of Air Curtains Standard, 1 and 2 m

· Installation Height up to 3.5 m (Jet-Flow) and 3.0 m (Standard)· Outlet Grilles can be adjusted in five positions, to suite different Indoor and

installation requirements (Jet-Flow)· Control with Panasonic Remote Control systems (optional)· Direct integration to BMS by optional Panasonic Interfaces· Drain included for cooling operation· Drain pump and float switch available for forced drainage

Features

COMFORT· Easy redirection of Air-Flow by means of manual deflector (Jet-Flow)

EASE OF USE· Speed selectable on remote controller with 3 speeds

EASY INSTALLATION AND MAINTENANCE· Easy installation· Compact dimensions improve installation and positinioning (Jet-Flow)· Easy cleaning of grid without opening of the unit· Continuos operation even in case of 1 fan motor failure without stopping air curtain

function or stopping the complete system· Warning indication on remote controller display

PAW-10PAIRC-MJ PAW-15PAIRC-MJ PAW-20PAIRC-MJ PAW-25EAIRC-MJA 1.000 1.500 2.000 2.500

159

COMMERCIAL

PCB, Power trans, Terminal block

AHU Connection Kit

Remote controller

Standard wired remote controller (optional).Can be installed inside the box.

Thermistor x2(Refrigerant: E1, E2)

Thermistor(Air: TA; 1 sensor)

Air Handling Unit Kit 10-25 kW for PACiNew AHU Kit connects PACi outdoor units to Air Handling Units systemThe Panasonic AHU Kits offer a wealth of connectivity possibilities so can be easily integrated into many systems.Application: Hotels, offices, server rooms or all large buildings where air quality control such as humidity control and fresh air and is needed.

160

Panasonic AHU Kit, 10-25 kW connected to PACi outdoor unitThe new Air Handling Unit Kit has been developed to better meet customer demand:· IP 65 Box in order to be installed outside· 0-10V demand control (included on the CZ-CABP2 PCB)*· Easy control by BMS

* Only available with Elite PACi, up to from 6kW to 14kW.

PACi Air Handling Unit

I/D-O/D wiring

Wiring for Thermostat & Solenoid Valve

Piping

Air Handling Unit KitPAW-280PAH2

Controller wiringCZ-RTC2 (Optional)

Combination table for PACi single outdoor unitCombination shown in below table is available for PACi single systemPower Size PACi Standard PACi Elite AHU kitSingle Phase 5.0 kW U-50PEY1E5

PAW-280PAH2(Common use for all outdoor units. Only 1 by 1 connection is allowed.)

6.0 kW U-60PEY1E57.1 kW U-71PEY1E510.0 kW U-100PE1E5A12.5 kW U-125PE1E5A14.0 kW U-140PE1E5A

Three Phase 10.0 kW U-100PE1E8A12.5 kW U-125PE1E8A14.0 kW U-140PE1E8A20.0 kW U-200PE1E825.0 kW U-250PE1E8

* Additional notice/instruction for system design, installation work will be defined for PAC-i connection.

CZ-RTC2 Timer remote controller· Operation-ON/OFF· Mode select· Temperature setting

* Fan operation signal can be taken from the PCB.

CZ-T10 terminal · Input signal= Operation ON/OFF· Remote controller prohibition· Output signal= Operating-ON status· Alarm output (by DC12 V)

PAW-OCT, DC12 V outlet. OPTION terminal· Output signal= Cooling / Heating/Fan status· Defrost· Thermostat-ON

PAW-T10, PCB to connect to T10 connector· A Dry contact PCB has been developed to easily control the unit· Input signal operation ON/OFF· Remote control prohibition· Output signal operation ON status maximum 230 V 5 A (NO/NC)· Output signal alarm status maximum 230 V 5 A (NO/NC)· Additional available contacts:

- External humidifier control (ON/OFF) 230 VAC 3 A- External fan control (ON/OFF) 12V DC- External filter status signal potential free- External float switch signal potential free- External leakage detection sensor or TH. OFF contact potential free

(possible usage for external blow out temperature control)

Optional parts: Following functions are available by using different control accessories

0-10 v controlWith the 0-10 v demand control the capacity of the outdoor unit can be controlled by 20 steps

Analog input (V) Demand (%)0 (not connect) Free0.5 Stop1.0 401.5 452.0 502.5 553.0 603.5 654.0 704.5 755.0 805.5 856.0 906.5 957.0 1007.5 1058.0 1108.5 1159.0 1209.5 Free10.0 0 (TH. OFF)

161

COMMERCIALNEW

Operation System Individual Control Systems

Requirements Control for hotel application Wired remote controller Wireless remote controller

Quick and easy operation

External appearance

Type, model name Intelligent Controller Normal operation Design wired remote controller Wireless remote controller Simplified remote controller

Backlit remote controller

PAW-RE2C3-WHPAW-RE2C3-GRPAW-RE2C3-MOD-WHPAW-RE2C3-MOD-GRPAW-RE2C3-LON-WHPAW-RE2C3-LON-GR

Stand-Alone WhiteStand-Alone GreyModbus WhiteModbus GreyLonWorks WhiteLonWorks Grey

CZ-RTC2 CZ-RTC3 CZ-RWSU2 // CZ-RWSY2 //CZ-RWSL2 // CZ-RWSC3 //CZ-RWST2 // CZ-RWST3 // CZ-RWSK2

CZ-RE2C2 CZ-RELC2

Econavi Control — — — —

Power consumption monitor — — ² — —

Built-in Thermostat

I_O which can be controlled 1 indoor unit 1 group, 8 units 1 group, 8 units 1 group, 8 units 1 group, 8 units

Use limitations — · Up to 2 controllers can be connected per group

· Up to 2 controllers can be connected per group

· Up to 2 controllers can be connected per group

· CZ-RE2C2: up to 2 controllers can be connected per group

· CZ-RELC2: can not operate other (SUB) remo-con

Function ON/OFF

Mode setting AUTO

Fan speed setting

Temperature setting

Air flow direction — ¹ ¹

Permit/Prohibit switching — — — —

Weekly program — — —1. Setting is not possible when a remote control unit is present (use the remote control for setting). 2) Only for PACi Elite except 50 type. * All specifications subject to change without notice.

NEW NEW

162

Timer Operation Centralized Control Systems

Daily and weekly program Operation with various function from center station

Only ON/OFF operation from center station

Simplified load distribution ratio (LDR) for each tenant

BMS System. PC Base Connection with 3rd Party Controller

Schedule timer System controller ON/OFF Controller Intelligent Controller(Touch screen panel)

CZ-ESWC2 CZ-64ESMC2 CZ-ANC2 CZ-256ESMC2 (CZ-CFUNC2)

— — — —

— — — —

— — — —64 groups, maximum 64 units 64 groups, maximum 64 units 16 groups, maximum 64 units 64 units x 4 systems, max. 256 units

· Required power supply from the system controller

· When there is no system controller, connection is possible to the T10terminal of an indoor unit

· Up to 10 controllers, can be connected to one system

· Main unit/sub unit (1 main unit + 1 sub unit) connection is possible

· Use without remote controller is possible

· Up to 8 controllers (4 main units + 4 sub units)can be connected to one system

· Use without remote controller is impossible

· A communication adaptor (CZ-CFUNC2) must be installed for three or more systems

— —

— —

— —

— ¹ — ¹

— —

Control systems for PACi, ECOi and ECO GA wide variety of control options to meet the requirements of different applications.

For detailed information go to the VRF Control Systems section.

P-AIMS. Basic Software

CZ-CSWKC2

Optional software

CZ-CSWAC2 for Load distribution.CZ-CSWWC2 for Web application.CZ-CSWGC2 for Object layout display.CZ-CSWBC2 for BAC net software interface.*PC required (field supply)

Web Interface SystemsCZ-CWEBC2*PC required (field supply)

Seri-Para I/O unit for outdoor unit CZ-CAPDC2

Local adaptor for ON/OFF control CZ-CAPC2

MINI Seri-Para I/O Unit CZ-CAPBC2

Communication Adaptor CZ-CFUNC2

163

COMMERCIAL

Internet Control. Control your air conditioning system with your smart device -smartphone & internet for PACi

Control your comfort and effi ciency with the lowest energy consumption What’s Internet Control?Internet Control is a next generation system providing a user-friendly remote control of air conditioning or heat pump units from everywhere, using a simple Android or iOS smartphone, tablet or PC via internet.Simple InstallationJust connect the Internet Control device to the air conditioner or heat pump with the supplied wire and then link it to your WIFI Access point.

Internet Control. Easy to install. Maximum benefitInternet Control is underlined with the slogan “Your home in the cloud”, meaning a simple and easy to handle solution has been considered for every user to manage the device, not requiring any communication or computer skills.No servers. No adaptors. No wires. Just a small box is needed to be connected and placed close to the air conditioning indoor unit… and your smartphone, tablet or PC.Start the App from your smartphone device, your tablet or your computer, and enjoy a new experience in comfort. An intuitive and user-friendly application on the screen of your smartphone or PC that lets you manage the air conditioning unit in the same way you do with the remote controller.Internet Control can be downloaded in Apple’s AppStore and Android’s PlayStore.

Control your air conditioning with the smart internet control device via smartphones, tablet, PC and smart desktop phone via internetOffering the same functions as if you were at home or office: start/stop, Mode Operation, Set Temperature, Room Temperature etc as well as the new, advanced functionality provided by Internet Control to achieve the best comfort and efficiency with the lowest energy consumption.

KX-UT670 Smart Desktop Phone from Panasonic.Reference PA-RC2-WIFI-1

INTERNET CONTROL

OPTIONAL

InternetControlReady

CONTROL YOUR

AIR CONDITIONING FROM

EVERYWHERE

InternetControlReady

INTERNET CONTROL

OPTIONAL

Case Study. Alice, Shop Owner“I want maximum comfort and the best savings for my shop. And I manage to get these in the easiest and most natural way possible. From my smartphone, something I always carry with me, I can control the temperature of my shop and in this way, as well as maintaining an ideal temperature I also save a small fortune in electricity at the end of the year.”

Take control from wherever you are!

Interface Wifi Air Conditioning

Router Wifi

Internet service in the cloud*

Home or Office

* Functionalities depend on the license. The information indicated above is subject to changes and updates.

TabletSmartphoneComputer

164

PACi Connectivity. Easy connection to KNX, Modbus, LonWorks and BACnet

Panasonic model name

Interface Connected on the indoor unit

Maximum number of indoor units connected

PACi indoor units

PAW-RC2-KNX-1i KNX Indoor unit 1 (1 Group of Indoor units)PAW-RC2-MBS-1 Modbus RTU* Indoor unit 1 (1 Group of Indoor units)PA-RC2-WIFI-1 IntesisHome Indoor unit 1 (1 Group of Indoor units.)

* Interface Modbus RTU/TCP is needed

AIRZONE Interface

Room control

Air Outlet

Panasonic Partners have designed solutions specifically for Panasonic air conditioners, and provide complete monitoring, control and full functionality of the entire Commercial line-up from KNX / Modbus / LonWorks / BACnet installations.Great flexibility for integration into your KNX / Modbus / LonWorks / BACnet projects allows fully bi-directional monitoring and control of all the functioning parameters.

For more information, contact Panasonic.

Airzone. Control of the PACi Hide AwaysAirzone has developed interfaces to easily connect to Panasonic PACi Hide Away units. Ensuring optimum performance, comfort and energy savings, the new system is efficient and easy to install.

Airzone full range of accessories for any duct project

ON24 °C

ON22 °C

OFF

OFF

Different type of outlets Also plenum automatic doors

Full range of RC (wired/wireless, ...)

I_UPCB

Easycontrolby BMS

CONNECTIVITY

165

COMMERCIAL

PACi, ECOi and ECO G Connectivity indoor units

NOTE: The wire length from indoor unit to the Relay must be within 2.0 m. Pulse signal changeable to static with JP cutting. (Refer to JP001)

Operation ON/OFF signal output· Condition:

4-5 (Static output): 12 V output during the unit ON / No output at OFF· Example of wiring

· Condition1. 1-2 (Pulse input): Unit ON/OFF condition switching with a pulse signal.

(1 pulse signal: shortage status more than 300 msec. or more)2. 2-3 (Static input): Open / Operation with Remote is permitted.(Normal

condition) Close / Remote controller is prohibited.3. 4-5 (Static output): 12 V output during the unit ON. / No output at OFF.4. 5-6 (Static output): 12 V output when some errors occur / No output at

normal.· Example of wiring

T10 terminal Specification (T10: CN015 at indoor unit PCB)· Control items: 1. Start/stop input

2. Remote controller prohibit input3. Start signal output4. Alarm signal output

1

2

3

4

5

COM

COM+12 V

6T10 (yellow)

300 ms or more

Unit condition ON ONOFF

+12

1-2 (pulse input)

4-5 (output)

NOTE: The wire length from indoor unit to the Relay must be within 2.0 m. Pulse signal changeable to static with JP cutting. (Refer to JP001)

1

2

3

4

5

6

1

2

3

4

5

6

Central control

Indoor unit control PCB 2 m

Relay (Field supply)T10 (yellow)

T10 connector (CN015)

CZ-T10: Panasonic has developed an optional accessory (consisting of plug + wires) called CZ-T10 to enable an easy connection to this T10 connector.

Connecting an ECOi indoor unit to an external device is easy. The T10 terminal featured in the electronic circuit board of all indoor units enables digital connection to external devices.

EXAMPLE OF APPLICATIONS

Usage ExampleForced OFF controlTerm 1 & 2: Free contact for ON/OFF signal (cut *JP1* for static signal) when

the hotel card is it connected the contact must be close (the unit can be used).

Term 2 & 3: Free contact to prohibit all function in the remote controller install in the room when the hotel card is it removed the contact must be closed (the unit can not work).

Terminal = T10

123456

ON / OFFCOMMONPROIBIT

OPERATION OUTPUT +12 V DCCOMMON

OUTPUT ALARM +12 V DC

RELAY 12 V DC

PCB’s and cables for PACi, ECOi and ECO G indoor unitsName of the cables Function CommentCZ-T10 All T10 functions Requires field supplied accessoryPAW-FDC Operate external fan Requires field supplied accessoryPAW-OCT All option monitoring signals Requires field supplied accessoryCZ-CAPE2 Option monitoring signals wo. fan Requires aditional wires from spare part supplyPAW-EXCT Forced Thermo OFF/Leakage D. Requires field supplied accessoryName of the PBC Function CommentPAW-T10 All T10 functions Allows easy connection “Plug & Play”PAW-T10V All T10 functions + powermonitoring Same like PAW-T10 + monitoring the power supply of indoor unitPAW-T10H ON/OFF; Prohibit 5VDC & 230VAC Specials for single hotel card or window contactPAW-T10HW ON/OFF; Prohibit 5VDC For hotel card + window contact at same timePAW-PACR3 Redundancy of 2 or 3 systems; for PACi and ECOi Redundancy of 2 or 3 PACi systems including temperature monitoring, error indication, backup, alternative runPAW-SERVER-PKEA Redundancy of 2 units PKEA Redundancy of 2 units PKEA including temperature monitoring, error indication, backup, alternative run

166

Option Connector (CN060) Output external signals

1

2

3

4

5

6

1

2

3

4

5

6

DC 12V

With the combination of the T10 and the option CN060 an external control of the I_U is possible!

6P (WHITE): OUTPUTS EXTERNAL SIGNALS AS SHOWN IN THE FIGURE BELOW.Relay (DC 12V, field supply) (Note)

Indoor unit control PCB (CR1)

OPTION(white)

Fan signal

Heat start signal

Cool start signal

Thermostat signal

Defrost signal

Note: The relay must be installed at a distance of 2 m or less from the PCB.

Fan Drive Connector (CN032)

1

2

1

2

Indoor unit control PCB

Relay (field supply)

To external-control input terminal on ventilation fan

DC 12V

FAN DRIVE(2 plug (white))

Ventilation button

EXTERNAL FAN ON / OFF

PAW-OCT: Panasonic has developed an optional accessory (consisting of plug + wires) called PAW-OCT to enable an easy connection to this Option Connector (CN060).Operating the ventilation fan from the

remote controller· Start / stop of external ventilation and total

heat exchanger fans· Works even if indoor unit is stopped· In case of group control all fans will

operate; no individual control

PAW-FDC: Panasonic has developed an optional accessory (consisting of plug + wires) called PAW-FDC to enable an easy connection to this Fan Drive Connector (CN032).

EXCT Connector (CN009)

S

CN009

Valves close!

Signal

Signal

Signal

Ref. detectorRoom 1 Room 2

Leakage!

B) Example: In connection with a refrigerant sensor· Signal from leakage detector: non voltage, static.· Indoor unit setting: Code 0b 1· Connector for leak detector: EXCT· Outdoor unit setting: Code C1 1 power output if alarm from O2 connector 230 V Code C1 2 power output if alarm from O2 connector 0 V· Displayed alarm message P14

1

2

1

2

A) With static input STATIC INPUT THERMO OFF ENERGY SAVING

2P plug (red): Can be used for demand control. When input is present, forces the unit to operate with the thermostat OFF.

Note: The length of the wiring from the indoor unit control PCB to the relay must be 2m or less.* Lead wire with 2P plug (special—order part: WIRE K/854 05280 75300)

Relay (field supply)

Indoor unit control PCB

EXCT(2P plug (red))

Relay coil signal

· Examples of wiring:

PAW-EXCT: Panasonic has developed an optional accessory (consisting of plug + wires) called PAW-EXCT to enable an easy connection to this EXCT Connector (CN009).

167

COMMERCIAL

Possibleto use on

R22 pipings

R22 RENEWAL

R22 Renewal. Why renewal?Unique R22 Renewal from Panasonic: Fast, easy to install and Cost effective · Panasonic refrigerant oil doesn’t react to the most common oil types

used in air-conditioning systems. This ensures the mix of oil does not damage the units. Therefore installations are easier.

· All Panasonic PACi units can be installed in R22 pipings, no specific models are available.

· Up to 33 Bar! When there is any doubt about the strength of the piping, the maximum working pressure can be reduced to 33 Bar with a setting in the software of the outdoor unit.

An important drive to further reduce the potential damage to our ozoneIt is often said that legislation is ruling our lives but sometimes it is there to help save lives. R22 phase out can be described as one of these and from Jan 1st 2010 the use of Virgin (new) R22 refrigerant was banned within the European Community.

Panasonic are doing our part

We at Panasonic are also doing our part – recognising that all finances are under pressure at the moment. Panasonic has developed a clean and cost effective solution to enable this latest legislation to be introduced with as minimum an effect on businesses and cash reserves as possible.The Panasonic renewal system allows good quality existing R22 pipe work to be re-used whilst installing new high efficiency R410A systems.By bringing a simple solution to the problem Panasonic can renew all Split Systems and PACi systems; and depending upon certain restrictions we don’t even limit the manufacturer’s equipment we are replacing.By installing a new high efficiency Panasonic R410A system you can benefit from around 30% running cost saving compared to the R22 system.

Yes...1. Check the capacity of the system you wish to replace2. Select from the Panasonic range the best system to replace it with3. Follow the procedure detailed in the brochure and technical dataSimple...

R22 - The reduction of Chlorine critical for a cleaner future

Reuse of existing piping (Renewal Design & Installation)

Notes on reuse of existing refrigerant pipingIt is possible for each series of PE1 type and PEY1 type outdoor unit to reuse the existing refrigerant piping without cleaning when obtained under certain conditions.. Make sure that the requirements under the section “Notes on reuse of existing refrigerant piping”, “Measurement procedure for renewal” and “Refrigerant piping size and allowable piping length” will be satisfied in order to carry out .Also, check the items with regard to section “Safety” and “Cleaning”.

1. Prerequisite· If the refrigerant used for the existing unit is other than R22, R407C and R410A, the

existing refrigerant piping cannot be used.· If the existing unit has another use than air conditioning, then existing refrigerant piping

cannot be used.

2. Safety· If there is a hollow, crack or corrosion on the piping, make sure to install new piping.· If the existing piping is other than capable of reuse of piping as shown in the flowchart,

make sure to install new piping.· In case of multiple operation type, use our genuine branch piping for refrigerant R410A.

A local supplier shall assume responsibility for the defects and hollows on the reuse of existing piping surface and recognition of reliability of the piping strength. There is no guarantee that we take responsibility for such damages.The operational pressure of the refrigerant R410A becomes higher compared to R22. In the worst case, a lack of compressive strength may lead to piping explosion.

3. Cleaning· When the refrigerant oil used for the existing unit is other than the listed below, make

sure to install new piping or wash it thoroughly before reusing it.[Mineral Oil] SUNISO, FIORE S, MS[Synthesized oil] alkyl benzene oil (HAB, parallel freeze), ester oil, ether oil (PVE only)

If the existing unit is GHP type, it is necessary to wash the piping thoroughly.

· If the existing pipes in the outdoor and indoor units remain disconnected, make sure to install a new piping or wash it thoroughly before reusing it.

· If the discoloured oil or residue remains in the existing piping, make sure to install a new piping or wash it thoroughly before reusing it. See “Deterioration Criteria for Refrigerant Oil” in table 3.

· If the compressor of the existing air conditioner has a failure history, make sure to install a new piping or wash it through thoroughly before reusing it.

When reusing the existing piping as it is without removing dirt and dust, inadequate piping could result a renewal appliance in failure.

168

Notes on renewal for simultaneous operation of multiple unitsOnly main pipe is applicable for using the different diameter size.In case of different diameter size for the branch pipes, a new installation work for a standard size is necessary.Be sure to use our genuine branch piping for refrigerant R410A.

Notes on Renewal for Simultaneous Operation of Multiple UnitsCapacity class Standard liquid pipe size Standard gas pipe sizeType 50 Ø 6,35 Ø 12,7Type from 60 to 140 Ø 9,52 Ø 15,88Type 200 Ø 9,52 Ø 25,4Type 250 Ø 12,7

· Only the main pipe L can be used among different diameter’s existing piping.

· Installation work as a standard size is capable for L1, L2, l1 - l4 piping.· Be sure to use our genuine branch piping for refrigerant R410A.

1. In case of single unitIt is not necessary to charge with additional refrigerant until the chargeless pipe length in the table 2.If the pipe length is exceeding the charge less pipe length, charge with additional refrigerant amount per 1 m according to the equivalent length.

2. In case of simultaneous operation of multiple unitsCalculate the refrigerant charging amount according to the calculating method of the standard piping diameter.As to the additional refrigerant charging amount per 1 m, refer to the additional amount in the table 2.

21

L

L1 L2

43

Main pipe

Branch pipe

Measurement Procedure for Renewal

Observe the following procedure when reusing the existing piping or carrying out renewal installation work.Flowchart of Existing Piping Measures Criteria for PE1 Type and PEY1 Type Outdoor Unit

START

Do existing piping size and piping length satisfy the standard under the conditions?

Can existing air conditioner run in the cooling mode?

Perform the test operation in cooling mode for over 30 minutes and collect the remaining refrigerant without stopping operation.

Remove existing indoor and outdoor units

Check inside the piping from the pipe end.

Is the oil remained inside the piping transparent?

Is the residue inside the piping removed?

Has the compressor in existing air conditioner been operated without any trouble?

Carry out the installation work according to Installation Instructions.

Existing refrigerant piping cannot be used as is.Make sure to install a new piping.

Collect the refrigerant by the refrigerant recovery equipment.

Remove existing indoor and outdoor units

Wash it thoroughly or make sure to install a new piping.Existing refrigerant piping cannot be used as is.

See Table 1 – 2

See Table 3Level “3 Over” according to colour scale level

· Use our genuine branch piping for refrigerant R410A.· Re-process the flare of existing piping for R410A and use

the flare nut attached to the service valve of the outdoor unit (for R410A).

Yes

Yes

Yes

Yes

Yes

No

No

No

No

No

Opposite side dimension of flare nut (mm)Piping size Ø 6,35 Ø 9.52 Ø 12.7 Ø 15.88 Ø 19.05For R410A

17 2226 29

36For R22/R407C 24 27

169

COMMERCIAL

Refrigerant piping size and allowable piping length

Check if reuse of existing refrigerant piping is possible based on the following chart.The standards other than this one (difference of elevation, etc.) are identical to the requirements of ordinary refrigerant piping.

Table 1 Reusable existing piping (mm)Material O 1/2 H, H*External diameter Ø 6.35 Ø 9.52 Ø 12.7 Ø 15.88 Ø 19.05 Ø 22.22 Ø 25.4 Ø 28.58Thickness 0.80 0.80 0.80 1.00 1.00 1.00 1.00 1.00

* It is impossible to reuse the size of Ø 19.05, Ø 22.22, Ø 25.4 and Ø 28.58 for material O. Change to material 1/2H or material H.

Table 2 - 1 Refrigerant piping size: 3.6 - 14.0 kW type (mm)Liquid pipe Ø 6.35 Ø 9.52 Ø 12.7Gas pipe Ø 9.52 Ø 12.7 Ø 15.88 Ø 12.7 Ø 15.88 Ø 19.05 Ø 15.88 Ø 19.05PE Type 50 Standard

40 m(30 m)

40 m(30 m)

20 m(15 m)

20 m(15 m)

PEY Type 60Type 71 10 m

(10 m)10 m(10 m)

30 m(20 m)

Standard50 m(20 m)

25 m(10 m)

Additional refrigerant charging amount per 1 m

20 g/m 40 g/m 80 g/m

PE Type 60Type 71 10 m

(10 m)10 m(10 m)

30 m(30 m)

Standard50 m(30 m)

25 m(15 m)

Type 100Type 125Type 140

Standard75 m(30 m)

75 m(30 m)

35 m(15 m)

35 m(15 m)

PEY Type 100Type 125Type 140

Standard50 m(30 m)

50 m(30 m)

25 m(15 m)

25 m(15 m)

Additional refrigerant charging amount per 1 m

20 g/m 50 g/m 80 g/m

How to see table definition (example):In case of type 71, standard size is liquid pipe Ø 9.52 / gas pipe Ø 15.88.There is a limitation to liquid pipe Ø 9.52 / gas pipe Ø 12.7and to liquid pipe Ø 12.7 / gas pipe Ø 15.88.However, they are applicable for different diameter’s pipes.

Table 2 - 2 Refrigerant piping size: 20.0 - 25.0 kW type (mm)Liquid pipe Ø 9.52 Ø 12.7 Ø 15.88Gas pipe Ø 22.22 Ø 25.4 Ø 28.58 Ø 22.22 Ø 25.4 Ø 28.58 Ø 22.22 Ø 25.4 Ø 28.58PE Type 200

80 m(30 m)

Standard100 m(30 m)

100 m(30 m)

50 m(15 m)

50 m(15 m)

50 m(15 m)

Type 25080 m(30 m)

Standard100 m(30 m)

100 m(30 m)

65 m(20 m)

65 m(20 m)

65 m(20 m)

Additional refrigerant charging amount per 1 m

40 g/m 80 g/m 120 g/m

Allowable

Cooling capacity down

Limited piping length

Unallowable

50 m Maximum piping length

(50 m) Charge less piping length in a single connection

Table 3 Deterioration Criteria for Refrigerant Oil

0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0

R22 Renewal

170

290

80

22.2

256

270

1838

3879 8

R 2.5

R 5

Control equipment external dimensions

TIMER REMOTE CONTROLLER(CZ-RTC2)

SYSTEM CONTROLLER(CZ-64ESMC2)

INTELLIGENT CONTROLLER(CZ-256ESMC2)

COMMUNICATION ADAPTER(CZ-CFUNC2)

SEPARATE RECEIVER FOR WIRELESS REMOTE CONTROLLER

SIMPLIFIED REMOTE CONTROLLER(CZ-RE2C2)

REMOTE SENSOR(CZ-CSRC2)

4.4 x 9.4 slot

4.4 x 9.4 slot

ON/OFF CONTROLLER(CZ-ANC2)

SERI-PARA I/O UNIT FOR EACH INDOOR UNIT(CZ-CAPBC2)

LONWORKS INTERFACE(CZ-CLNC2)

SERI-PARA I /O UNIT FOR OUTDOOR UNIT(CZ-CAPDC2)

4 - Ø 5 hole

Magnified viewDetail of the potbellied hole

3 - Ø 30 holePotbellied hole (4 locations)

WIRELESS REMOTE CONTROLLER

Control Systems

171

COMMERCIAL

PKEA dimensions

Wall Mounted PKEA

32030

695

320 30

695

875 70131 613 131

361

3885151

2570

75

29937

622

299 37

622

824 68124 540 160

330

32

97167

2369

61

1070255

295

42

60

1070255

255

11960

106

60

1070

(41-61)410

870

870255

255

11960

106

60

870

(41-61)590

TOP VIEW

TOP VIEW

TOP VIEW

TOP VIEW

BOTTOM VIEW BOTTOM VIEW

FRONT VIEW FRONT VIEW

FRONT VIEW FRONT VIEW

SIDE VIEW

SIDE VIEW SIDE VIEWSIDE VIEW SIDE VIEW

REAR VIEW REAR VIEW

Air outlet direction

Air intake direction

Left piping hole

Right piping hole

Dimensions: mm

3-way valve al gas side (Low Pressure

3-way valve al gas side (Low Pressure2-way valve al liquid side

(High Pressure2-way valve al liquid side (High Pressure

CS-E9PKEA // CS-E12PKEA

CU-E9PKEA // CU-E12PKEA

CS-E15PKEA // CS-E18PKEA

CU-E15PKEA // CU-E18PKEA

172

PACi Standard and Elite dimensions

Wall

4-Way 60x60 Cassette

1065

230 (2.5)197.4

140

158415

439.8

496.8

415

448.2

568.2

132

0025959

0543.483

68

300

48(Ø80)

17.9

37.3

48

230.7

148.760 8

70 115.9

115.9

300

11 67

60

8667

(Ø80)

5cm 5cm

7.5cm

2

1

3

4

5

Type 36 - 50 60 - 1001 Refrigerant tubing (liquid tube) Ø 6.35 (flared) Ø 9.52 (flared)2 Refrigerant tubing (gas tube) Ø 12.7 (flared) Ø 15.88 (flared)3 Drain hose VP13 Outer diameter Ø 184 Rear panel PL BACK5 Tubing and wiring holes Ø 80

Dimensions: mm

25

(583)

575

44 170

123

31

146

179 28

3

(288)

31

(23)

260

A

650

530

650

530

301

316

320

112

(583)

575

200

2

2

1

700

336

336

700

71

71

ø 80

45

4 3 6

5

7 212

1488

Panel center

Dimension of Fresh air intake duct (field supply) connection port

Adjust the suspension bolt length so that the gap from the lower ceiling surface becomes 45mm or more, as shown in the figure at right.If the suspension bolts is too long, it will contact the ceiling panel and the unit cannot be installed.

4-ø3Barring hole

(ceiling opening dimension)

(cei

ling

open

ing

dim

ensi

on)

A VIEW

(suspension bolt pitch)

(sus

pens

ion

bolt

pitc

h)

Dimensions: mm

1 Air intake2 Discharge outlet3 Refrigerant tubing (liquid tube) Ø 6.35 (flared)4 Refrigerant tubing (gas tube) Ø 12.7 (flared) 5 Drain tube connection port VP25 Outer dia. Ø 326 Power supply port7 Suspension bolt hole 4-11 x 26 hole8 Fresh air intake duct connection port Ø 80

173

COMMERCIAL

Low Static Pressure Hide Away

4 Way 90x90 Cassette

PACi Standard and Elite dimensions

840

480

2

35

4-Ø3

Ø162

Ø113

4-Ø3

80

115

300950

840

480

82 160

786

8

5 3 4

7

7

97

7

6

2

2

2

2

1

345

145 271 50

514

950

515

42

160

50(411)

745

130 167

130

95

B

160

118

18

30

860~

910

860~910

X

421

121

33.5

A

35

167

180 B

95

670

115

80

850

Type 36 - 71 100 - 1401 Air intake grill2 Air discharge outlet3 Refrigerant piping (liquid pipes) Ø 6.35 (flared) Ø 9.52 (flared)4 Refrigerant piping (gas pipes) Ø 12.7 (flared) Ø 15.88 (flared)5 Drain outlet VP50 Outer diameter 32mm6 Power supply port7 Discharge duct Ø 1508 Suspension bolt hole 4-12x30 slot9 Fresh air intake duct connection port Ø 100¹

1 Air inlet kit is necessary.Filter size: 520 x 520 x 16

Type 36 - 71 100 - 140A 256 319B 124 187

Adjust the suspension bolt length so that the gap from the lower ceiling surface becomes 30mm or more (18mm or more from the lower surface of the body) as shown in the figure. When the suspension bolt length is long, it hits the ceiling panel and installation is not possible.

(ceiling opening dimension)

(cei

ling

open

ing

dim

ensi

on)

Less than

Less than

Burring hole

Burring hole

Less than

X VIEW

(suspension bolt pitch)

(sus

pens

ion

bolt

pitc

h)

Dimensions: mm

740

523

64

250

80

670

840

900

780

20

45

55

55100

65

65

650 (P65 x 10)

585 (P65 x 9)

960

523

64

250

80

890

1060

1120

1000

20

57.5

55

55100

65

65

845 (P65 x 13)

780 (P65 x 12)

1160

523 650

30

134

30

64

250

80

1088

1260

1320

1200

20

48 65 48

23

18731 32

32 161 58

60

55

55100

65

65

1040 (P65 x 16)

975 (P65 x 15)

Drainage pipe connection

Air flow

Air flow

Drainage pipe connection

Air flow

Air flow

Drainage pipe connection

Air flow

Air flow

S-60PN1E5A // S-71PN1E5A S-100PN1E5A // S-125PN1E5A // S-140PN1E5AS-36PN1E5A // S-45PN1E5A // S-50PN1E5A

Dimensions: mm

174

High Static Pressure Hide Away

800

3232

33

3028

758

700

636

5

71 71150 x 3 = 450

812 - Ø3

867 (150)

35

700

2030256

130

26

89

300

65113

70

6

4

1

9

3

2

290

27

23

186

23140

172

280

7

7723

186

(75)

15459254

1000

32

33

32

758

3028

700

636

150

21 21150 x 5 = 750

1067

816 - Ø3

5(150)

35

700

2030256

130 70

140 2323

18627

290

2

3

9

1

4

6

113

65 300

89

26

172

280

7

7727

186

(75)54 154792

1 Refrigerant tubing joint (liquid tube) Ø 6.35 flare2 Refrigerant tubing joint (gas tube) Ø 12.7 flare3 Upper drain port VP25 Outer diameter 32mm

200 flexible hose supplied

4 Bottom drain port VP 25 Outer diameter Ø 32mm5 Suspension lug 4-12 x 30mm6 Power supply outlet7 Fresh air intake port Ø 150mm8 Flange for flexible air outlet duct9 Electrical component box

1 Refrigerant tubing joint (liquid tube) Ø 9.52 flare2 Refrigerant tubing joint (gas tube) Ø 15.88 flare3 Upper drain port VP25 Outer diameter Ø

32mm 200 flexible hose supplied

4 Bottom drain port VP 25 Outer diameter 32mm5 Suspension lug 4-12 x 30mm6 Power supply outlet7 Fresh air intake port Ø 150mm8 Flange for flexible air outlet duct9 Electrical component box

Dimensions: mm

S-36PF1E5A // S-45PF1E5A // S-50PF1E5A

S-60PF1E5A // S-71PF1E5A

Inspection acces450 x 450(Field supply)

Inspection acces450 x 450(Field supply)

Filter

Filter

holes

holes

(Suspension bolt pitch)

(Suspension bolt pitch)

(Flange O.D.)

(Flange O.D.)

175

COMMERCIAL

High Static Pressure Hide Away (Cont.)

5

20 - Ø38

(150)1467

150 x 7 = 1050 7171

33

150

636

700

758

3028

3232

1400 27

3025

6

130

26

89

30065

113

70

6

4

1

9

3

2

290

23

186

231402070

0

35

280

7

172

186

7727

154

(75)

119254

Dimensions: mm

S-100PF1E5A // S-125PF1E5A // S-140PF1E5A

Inspection acces450 x 450(Field supply)

Filter

holes

(Suspension bolt pitch)

(Flange O.D.)

1 Refrigerant tubing joint Ø 9.52 flare (liquid)2 Refrigerant tubing joint Ø 15.88 flare (gas)3 Upper drain port VP25 O.D. Ø 32mm) 200

flexible hose supplied

4 Bottom drain port VP 25 Outer diameter 32mm5 Suspension lug 4-12 x 30mm6 Power supply outlet7 Fresh air intake port Ø 150mm8 Flange for flexible air outlet duct9 Electrical component box

176

Ceiling

50cm

E

90

70

8690

9

250 250A

D

7

190

265

73114

123 61

1 8

B193131

80

216

186

C

5

15 4

43

2

216

6

176

96

1226

250 25050cm

90

70

8690

9

1275

1269

7

190

265

73114

123 61

1 8690

216

18680

131

193

235

5

415

43

2

216

6

176

96

(suspension bolt pitch)

(suspension bolt pitch)

Air intake

Air intake

Air discharge

Air discharge

(Closed with rubber stopper at time of shipment.) (Left drain position)

(Closed with rubber stopper at time of shipment.) (Left drain position)

Over

Over

Service space

Service space

Service space

Service space

(Gas tubing)

(Liquid tubing)

(Right drain position)

(Gas tubing)(Liquid tubing)(Right drain position)

Tubing hole position on wall surface(Figure shows view from front)

Tubing hole position on wall surface(Figure shows view from front)

Over

Over

(sus

pens

ion

bolt

pitc

h)

(sus

pens

ion

bolt

pitc

h)

Appr

ox. 2

°Ap

prox

. 2°

Min

imum

Min

imum

Dimensions: mm

1 Drain port VP20 Inside diameter Ø 26mm, drain hose supplied2 Left drain position3 Refrigerant liquid tubing Ø 9.52mm, flare connection4 Refrigerant gas tubing Ø 15.88mm, flare connection5 Left side drain hose outlet port (cutout)6 Tubing hole on wall surface Ø 100mm7 Upper side tubing port8 Right side drain hose outlet port (cutout)9 Wireless remote controller receiver installation location

A B C D E100-125 type 1,590 230 690 1,584 1,541140 type 1,655 360 820 1,599 1,606

S-60PT2E5A // S-71PT2E5A

S-100PT2E5A // S-125PT2E5A

177

COMMERCIAL

Outdoor Unit PACi Standard 6.0 and 7.1 kW and PACi Elite 5.0 kW

High Static Pressure Hide Away 20,0-25,0 kW

PACi Standard and Elite dimensions

479300

100 100

2

100 100

42

1428

1310

711100

51

1170

9649 x 100P = 900

4 - 37 x 12

26-Ø3.5

28-Ø3.5

10 x 100P = 1000106

44

10701310

67 671200

113

(236) 3643641334

60

43320

5017823

209344

1230

41

3

5

6

4

1

2

200 2501 Refrigerant liquid line Ø 9.522 Refrigerant gas line Ø 19.05 Ø 22.223 Power supply outlet4 Drain port Outer diameter 32 mm5 Duct connection for suction6 Duct connection for discharge

(holes all around)

(holes all around)

(suspension bolt pitch)

(suspension bolt pitch)

(hole for suspension bolt)

Dimensions: mm

790 70

569

15

12

50 50

249 320

(97)

100

46

(13)

(23.5)

27.5 13

50 50

12

46

85608

285

336

310

(157)153

(161)

51

149 25

110

109

4

1

2

3

2

5

Type 50 Elite 60 - 71 Standard1 Drain port Ø 182 Drain port Ø 193 Anchor bolt hole (Anchor bolt M8) 4-o124 Refrigerant tubing joint (gas tube) Ø 12.7 (flare) Ø 15.88 (flare)5 Refrigerant tubing joint (liquid tube) Ø 6.35 (flare) Ø 9.52 (flare)

Air intake

Air intake

Air discharge

Dimensions: mm

178

Outdoor unit PACi Standard 10.0 and 12.5 kW and PACi Elite 6.0 and 7.1 kW

200

300

500

100

170 620

70

13

13

940

2

1

35

60

86

60

35

60

60

42

31.5 61

34038

9016.5

6026

7654

7

7

6

6

5

4

3

340

380.5

10

21

19.5

996

462

120

120

69 53

76

16

10

3981

48

430

48120

3981

24

19.5

18

410

150

1 Mounting hole (4-R6.5), anchor bolt M102 Refrigerant piping (liquid pipe) Ø 9.52 (flared)3 Refrigerant piping (gas pipe) Ø 15.88 (flared)4 Electrical wiring port Ø 135 Electrical wiring port Ø 226 Electrical wiring port Ø 277 Electrical wiring port Ø 35

Air intake

or more

Air intake side

Air outlet side

Space for piping, wiring and maintenance

or more

or more

Air intake

Z

Z VIEW

Air discharge

Air discharge

Dimensions: mm

179

COMMERCIAL

Outdoor unit PACi Standard 14.0 kW and PACi Elite from 10.0 to 14.0 kW

PACi Standard and Elite dimensions

200500

100

300

170 620

70

13

13

9401

340

380.5

10

21

19.5

19.5

18

410

150

606026

7654

35

48

490

522

1416

120

3981

24

2

3

60

42

9016.5

7 6

120

69 5316

86

60

35

60

7

6

5

4

120

10

3981

48

34038

31.5 61

76

1 Mounting hole (4-R6.5), anchor bolt M102 Refrigerant piping (liquid pipe) Ø 9.52 (flared)3 Refrigerant piping (gas pipe) Ø 15.88 (flared)4 Electrical wiring port Ø 135 Electrical wiring port Ø 226 Electrical wiring port Ø 277 Electrical wiring port Ø 35

Air intake

or more

Air intake side

Air outlet side

Space for piping, wiring and maintenance

or more

or more

Z

Z VIEW

Air discharge

Dimensions: mm

180

Outdoor unit Big PACi Elite 20.0 and 25.0 kW

8

8 57

60

42

49

111

586

3077

22

39

940

A

18

410

1020

380

26290

105 219 75 75

170 660 110

13

60

340

4013

B

R30

5.5 62 49

677.5

638058

6149

340

7 59

60

333

52

4665

121

43

42

49

111

3077

85 64

22

60

1526

25

8

5

6

8

4

7

5

684

1

2

3

4

5 6

7

7

Type 20 251 Mounting hole (4-R6.5), anchor bolt M102 Refrigerant tubing (liquid tube) Ø 9.52 (flared) Ø 12.7 (flared)3 Refrigerant tubing (gas tube) Ø 19.05 (flared)4 Refrigerant tubing port5 Electrical wiring port Ø 166 Electrical wiring port Ø 197 Electrical wiring port Ø 298 Electrical wiring port Ø 38

Remark: There are two types of supplied tubings. The one tubing port Ø 19.05 (flare process) is connected to the flared connection of the gas port side’s service valve. The other “L” shaped tubing port is brazed in connection after cutting the tube at the proper length. Then make a brazing connection to the main tubing (Ø 25.4).

Name Figure Q’ty

Reducing Joint Tube(Ø 19.05 Ø 25.4)

1

Joint Tube (Ø 19.05) 1

2 x Ø 32 holes (holes for drain)Of the 4 Ø 32 holes , use 1 of the 2 holes specified for drain use to install the port. Use rubber plugs to seal the remaining 3 holes.

Air intake

Air intake

Air intake

Air discharge

Air discharge

Anchor boltAnchor bolt

Anchor bolt

Anchor bolt

Anchor bolt

VIEW ABottom removable connection port

VIEW BRefrigerant tubing connection port

Dimensions: mm

181

COMMERCIAL