CE 0694 TA99E006.A0105 Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE FOR HIGH EFFICIENCY CONDENSING BOILERS NON-CONDENSING BOILERS

Transcript of FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories...

Page 1: FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories guide for high efficiency condensing boilers non-condensing boilers . ... rbs 20 e 3

CE 0694 TA99E006.A0105

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

FLUE KIT OPTIONS

FLUE ACCESSORIES GUIDE

FOR HIGH EFFICIENCY CONDENSING BOILERS NON-CONDENSING BOILERS

Page 2: FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories guide for high efficiency condensing boilers non-condensing boilers . ... rbs 20 e 3

COAXIAL Flue systems – Non Condensing boilers

Flue kit options kit A kit A Telescopic kit G kit C

descriptions

horizontal-coaxial flue kit system with intake / exhaust pipes D. 100/60

telescopic horizontal-coaxial flue kit system with intake / exhaust pipes D. 100/60

horizontal-coaxial flue kit system with intake / exhaust pipes D. 125/80

vertical – coaxial flue kit system with intake / exhaust pipes D. 118/80 kit C

code 82012LP 82077LP 82081LP 82050LP

flue kits →

models ↓ max. flue length

(metres) max. flue length

(metres) max. flue length

(metres) max. flue length

(metres)

RS 20 E 3 3 3 RS 24 E 3 3 3 RS 30 E 3 3 RBS 20 E 3 3 - 3 RBS 24 3 3 - 3 RSF 20 E 3 3 - 3 RSF 24 E 3 3 - 3 RSF 30 E 3 3 RMAS 20 E 3 3 3 RMAS 24 E 3 3 3 RMAS 30 E 3 3 RS 21 E/3S 3 3 3 RSF 21 E/3S 3 3 3 RMAS 21 E/3S 3 3 3 RBA CS 24 E 3 3

RBA CS 30 3

RBA CS 100 E 3 3 3 RBA CS 30/100 3 3 SF 14 3 3 3

CE 0694 TA99E006.A0105

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

Page 3: FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories guide for high efficiency condensing boilers non-condensing boilers . ... rbs 20 e 3

TWIN PIPE FLUE SYSTEMS – Non condensing boilers

CE 0694 TA99E006.A0105

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

Flue kit options kit B kit D - -

descriptions horizontal double pipes flue kit system with intake / exhaust pipes D. 80/80

horizontal double pipes flue kit system with intake / exhaust pipes D. 80/80

- -

code 82046LP 82053LP - -

flue kits →

models ↓ max. flue length

(metres) max. flue length

(metres)

RS 20 E 30

RS 24 E 30

RS 30 E 30

RBS 20 E 30

RBS 24 30

RSF 20 E 30

RSF 24 E 30

RSF 30 E 30

RMAS 20 E 30

RMAS 24 E 30

RMAS 30 E 30

RS 21 E/3S 32

RSF 21 E/3S 32

RMAS 21 E/3S 32

RBA CS 24 E 26

RBA CS 30 26

RBA CS 100 E 30

RBA CS 30/100 30

SF 14 30

Note: For the double pipes flue kit system, the maximum length of the exhaust pipe must not exceed 2/3 of the total

permitted length as shown in the above table.

Page 4: FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories guide for high efficiency condensing boilers non-condensing boilers . ... rbs 20 e 3

FLUE KIT SYSTEMS FOR CONDENSING BOILERS

CE 0694 TA99E006.A0105

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

Flue kit options kit H kit K kit V

descriptions horizontal double pipes flue kit system with intake / exhaust pipes D. 80/80 in pps

horizontal-coaxial flue kit system with intake / exhaust pipes D. 100/60 in pps

vertical-coaxial flue kit system with intake / exhaust pipes D. 100/60 in pps

code 82086LA 82087LA 82091LA

flue kits →

models ↓ max. flue length *

(metres) max. flue length

(metres) max. flue length

(metres)

RK 25 50 5 5

RKR 25 50 5 5

RKA 25 50 5 5

RKA 100 50 5 5

Note: Horizontal double pipes flue kit system with intake / exhaust pipes ø60/60 in pps:

max. flue length (metres): 30

Note: For the double pipes flue kit system, the maximum length of the exhaust pipe must not exceed 2/3 of the total

permitted length as shown in the above table.

Page 5: FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories guide for high efficiency condensing boilers non-condensing boilers . ... rbs 20 e 3

Flue Kit Systems for EXTERNAL INSTALLATION boilers – Non condensing boilers

CE 0694 TA99E006.A0105

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

Flue kit options kit A Rain kit E kit F kit BOX

descriptions

horizontal-coaxial flue kit system with intake / exhaust pipes D. 100/60

single pipe flue kit system for external installation with exhaust pipe D. 80

single vertical pipe flue kit system for external installation with exhaust pipe D. 80

single pipe flue kit system for external installation with exhaust pipe D. 80

code 82054LP 82052LP 82072LP 82095LP

flue kits →

models ↓ max. flue length

(metres) max. flue length

(metres) max. flue length

(metres) max. flue length

(metres)

RAIN 30 E/R 3 15 3

RBS 20 E / Midyrain 15 3

RAIN 20 E 3 15 3

RAIN 24 E 3 15 3

RSF 20 E / Slimbox 15 RSF 24 E / Slimbox 15 RSF 30 E / Slimbox 15 RBS 20 E / Midybox 15 RMAS 20 E / Plusbox 15 RMAS 24 E / Maxibox 15 RMAS 30 E / Superbox 15

Page 6: FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories guide for high efficiency condensing boilers non-condensing boilers . ... rbs 20 e 3

ACCESSORIES for COAXIAL FLUE SYSTEMS – Non condensing boilers

CE 0694 TA99E006.A0105

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

drawing equal length

Leq code description kit A kit A

Rain kit A

Telescopic kit C kit G

- 27041LA roofing slate •

1.5 27051LA 90° flue bend D.125/80 extension kit •

0.5 27057LA 45° flue bend D.125/80 extension kit •

- 27069LA Roof slate for flat type roof •

- 64052LP adjustable diaphragm D.100 • • • • •

0.8 82009LP 90° flue bend D.100/60 extension kit • • •

0.5 82027LP 45° flue bend D.10060 extension kit • • •

- 82031LP D.100/95 clamp+rubber seal kit • • •

1 82036LP horizontal flue "KIT A" extension

D.100/60 1 mt. MF • • •

- 82042LP D.100/100 clamp+rubber seal kit • • • •

0.4 82045LP vertical connection kit D.100/60 w/test point •

1 82060LP vertical flue “KIT C” extension D.118/80 - 1 mt. •

1 82082LA 1 mt. extension D.125/80 •

Page 7: FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories guide for high efficiency condensing boilers non-condensing boilers . ... rbs 20 e 3

ACCESSORIES for TWIN Pipe system – Non condensing boilers

CE 0694 TA99E006.A0105

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

drawing equal length

Leq code description kit B kit BOX kit D kit E kit F

0.5 27018LA water trap connection D.80 w/test point •

- 52530LP D.80 intake/exhaust connection kit •

- 52561LP D.80 intake/exhaust connection “ KIT E” • • • •

- 64053LP adjustable diaphragm D.80 • • •

1.5 82032LP 90° flue bend D. 80 m/f kit wide radius no test point •

1.2 82033LP 45° flue bend D.80 MF extension kit •

- 82034LP D.80 clamp + rubber seal kit • • • • •

0.8 82035LP flue "KIT B" extension D.80 1 mt. MF • • •

3 82037LP 90° flue bend D.80 MF extension kit • • •

- 82044LP 90° flue bend D.80 MF wide radius

w/test point • • •

Page 8: FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories guide for high efficiency condensing boilers non-condensing boilers . ... rbs 20 e 3

ACCESSORIES FOR CONDENSING BOILER FLUE KIT SYSTEMS

CE 0694 TA99E006.A0105

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

drawing equal lengthLeq code description kit H kit K kit V

27047LA 90° flue bend D.60 MF extension kit •

27048LA 45° flue bend D.60 MF extension kit •

27049LA kit "T" connection D.60 MF •

27050LA exhaust / intake vertical connection D.80 •

27053LA 45° flue bend D.60/100 MF extension • •

27054LA 90° flue bend D.100/60 MF extension • •

27055LA 90° flue bend D.80 FF extension kit •

27056LA 45° flue bend D.80 MF extension kit •

27057LA 45° flue bend D.100/60 MF • •

27058LA roof slate (for flat type roof) •

27059LA roof slate (for slope type roof) •

27060LA coaxial connection D.100/60 MF for kit V •

Page 9: FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories guide for high efficiency condensing boilers non-condensing boilers . ... rbs 20 e 3

ACCESSORIES FOR CONDENSING BOILER FLUE KIT SYSTEMS

CE 0694 TA99E006.A0105

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

drawing equal lengthLeq code description kit H kit K kit V

52530LP exhaust / intake vertical connection D.80 •

82083LA condensation trap D.60 •

82084LA "KIT K“ 1 mt. extension D.100/60 MF • •

82085LP "KIT H“ 1 mt. extension D.60 MF •

82088LA kit D.80/60 adapter •

82090LA "KIT H” 1 mt. extension D. 80 MF •

Page 10: FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories guide for high efficiency condensing boilers non-condensing boilers . ... rbs 20 e 3

PARTS ONLY for COAXIAL FLUE SYSTEMS – Non condensing boilers

CE 0694 TA99E006.A0105

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

drawing equal length Leq code Description kit A kit A

Rain kit A

Telescopic kit C

0.8 27002LA 90° flue bend D.100/60 for extension • • •

0.1 27011LA vertical connection D.100x68 for "KIT A

RAIN" •

0.1 27014LA flange D.100 for vertical connection • •

0.5 27029LA 45° flue bend D.100/60 • • •

0.4 27035LA vertical coaxial connection D.100/60 w/test

point • •

1.5 27037LA vertical coaxial connection D.118/80 MF

w/test point •

0.5 27038LA flue bend D.100/60 w/test point for "KIT A

RAIN" •

0.8 27042LA flue bend D.100/60 w/test point and flange •

- 38502LA fixing clamp D.100 • •

- 43012LA external rubber wall seal D.100 • •

- 43056LA rubber collar D.100/95 pipe-bend • •

- 43066LA rubber collar D.100/100 pipe-pipe • •

- 43085LA neoprene sealing gasket D.100 (128x98) • • •

- 43111LA rubber collar D.95/95 bend-bend coaxial • •

- 54002LA internal/external flue pipes separator • •

- 64052LP adjustable diaphragm D.100 • • • •

2 80010LA flue terminal D.60.5 • •

Page 11: FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories guide for high efficiency condensing boilers non-condensing boilers . ... rbs 20 e 3

PARTS ONLY for COAXIAL FLUE SYSTEMS – Non condensing boilers

CE 0694 TA99E006.A0105

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

drawing equal length Leq code Description kit A kit A

Rain kit A

Telescopic kit C

1 82001LP inner flue pipe D.60x920 aluminium • •

1 82002LP pipe D.60x1000 MF white for extension • •

1 82004LP pipe D.100x905 white w/edge for "KIT A" • •

1 82005LP pipe D.100x1000 MF white for extension • •

1 82006LP pipe D.118x1000 MF aluminium for "KIT C"

extension •

1 82017LP pipe D.60x1000 MF aluminium for extension •

82018LP pipe D.80x1000 MF aluminium for "KIT C"

extension •

1 82019LP inner flue pipe D. 60x920 white for "KIT A"

Page 12: FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories guide for high efficiency condensing boilers non-condensing boilers . ... rbs 20 e 3

PARTS for TWIN PIPE FLUE SYSTEMS – Non condensing boilers

CE 0694 TA99E006.A0105

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

drawing equal lenght Leq code description kit B kit D kit E kit F

1.2 27028LA 45° flue bend D. 80 MF • • • •

1.5 27030LA 90° flue bend D.80 MF wide radius • • • •

- 27033LA vertical connection D.80 exhaust w/test point • • • •

- 27034LA vertical connection D.80 intake w/test point • • • •

1.2 27036LA 90° flue bend D.80 MF w/test point • • • •

1.5 27039LA 90° flue bend D.80 MF wide radius w/test point • • • •

- 38505LA fixing clamp D.80 • • • •

- 43023LA rubber collar D.80 • •

- 43031LA exhaust fan D.54 rubber seal • •

- 43057LA red washer D.80 • • • •

- 43088LA noprene sealing gasket D.80 (98x80) • • • •

- 43090LA external rubber wall seal D.80 for "KIT B" • • •

- 43102LA external rubber seal rain protection for "KIT E" •

- 43103LA rubber washer D.60 double edge •

- 43104LA vertical connection D.80 exhaust for "KIT E" •

- 43105LA Rubber collar D. 80 double edge • • •

Page 13: FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories guide for high efficiency condensing boilers non-condensing boilers . ... rbs 20 e 3

PARTS for TWIN PIPE FLUE SYSTEMS – Non condensing boilers

CE 0694 TA99E006.A0105

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

drawing equal lenght Leq code description kit B kit D kit E kit F

0.15 44509LA Metallic grid for "KIT E" •

- 64053LP adjustable diaphragm D.80 • • • •

- 80003LA stainless steel terminal D.80 • •

- 80004LA air intake flue terminal D.80 nylon • •

- 80005LA flue terminal D.80 for outdoor installation • •

- 80007LA flue terminal D.80 exhaust GB • •

- 80009LA terminale D.80 antivento • • •

1 82003LA pipe D.80 x 1000 mm MF white for extension • • • •

1 82073LP pipe D.80 x 700 w/inspection •

Page 14: FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE Files/flue kit... · flue kit options flue accessories guide for high efficiency condensing boilers non-condensing boilers . ... rbs 20 e 3

RADIANT BRUCIATORI s.p.a. Via Pantanelli, 164/166 - 61025 Loc. Montelabbate (PU) Tel. +39 0721 9079.1 • fax. +39 0721 9079279 e-mail: tecnico@radiant • Internet: http://www.radiant.it

DATI TECNICI E MISURE NON SONO IMPEGNATIVE. LA DITTA SI RISERVA IL DIRITTO DI EVENTUALI VARIAZIONI SENZA L'OBBLIGO DI PREAVVISO. DECLINIAMO OGNI RESPONSABILITÀ PER EVENTUALI INESATTEZZE CONTENUTE NEL PRESENTE OPUSCOLO, SE DOVUTE AD ERRORI DI STAMPA O DI TRASCRIZIONE. E+OE TUTTI I DIRITTI SONO RISERVATI. NESSUNA PARTE DI QUESTO DOCUMENTO PUÒ ESSERE RIPRODOTTA, MEMORIZZATA IN SISTEMI D’ARCHIVIO, O TRASMESSA IN QUALSIASI FORMA O MEZZO ELETTRONICO, MECCANICO, FOTOCOPIA, REGISTRAZIONE O ALTRI, SENZA LA PREVENTIVA AUTORIZZAZIONE SCRITTA DELLA DITTA.

TA01E006.A0105