 CE 0694 TA99E006 .A0105 Technical Specification RADIANT BRUCIATORI S.p.A.  Montelabbat e (PU) ITALY ENGLISH FLUE KIT OPTIONS FLUE ACCESSORIES GUIDE FOR HIGH EFFICIENCY CONDENSING BOILERS NON-CONDENSING BOILERS

Transcript of Flue Kit Guide

7/27/2019 Flue Kit Guide

http://slidepdf.com/reader/full/flue-kit-guide 1/14

 

CE 0694  TA99E006.A0105 

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH 

FLUE KIT OPTIONS

FLUE ACCESSORIES GUIDE

FOR

HIGH EFFICIENCY CONDENSING BOILERS

NON-CONDENSING BOILERS

7/27/2019 Flue Kit Guide

http://slidepdf.com/reader/full/flue-kit-guide 2/14

  COAXIAL Flue systems – Non Condensing boilers

Flue kit options kit A kit A Telescopic kit G kit C

descriptions

horizontal-coaxialflue kit systemwith intake /exhaust pipes D.100/60

telescopic horizontal-coaxial flue kit systemwith intake / exhaustpipes D. 100/60

horizontal-coaxial fluekit systemwith intake / exhaustpipes D. 125/80

vertical – coaxial fluekit systemwith intake / exhaustpipes D. 118/80 kit C

code 82012LP 82077LP 82081LP 82050LP

flue kits → 

models ↓ max. flue length

(metres) max. flue length

(metres) max. flue length

(metres) max. flue length

(metres) 

RS 20 E 3 3  3 RS 24 E 3 3  3 

RS 30 E 3 3 

RBS 20 E 3 3  - 3 

RBS 24 3 3  - 3 

RSF 20 E 3 3  - 3 

RSF 24 E 3 3  - 3 

RSF 30 E 3 3 

RMAS 20 E 3 3  3 

RMAS 24 E 3 3  3 RMAS 30 E 3 3 

RS 21 E/3S 3 3  3 

RSF 21 E/3S 3 3  3 

RMAS 21 E/3S 3 3  3 

RBA CS 24 E 3 3 

RBA CS 30 3

RBA CS 100 E 3 3 3 

RBA CS 30/100 3 3 

SF 14 3 3 3 

CE 0694  TA99E006.A0105 

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH 

7/27/2019 Flue Kit Guide

http://slidepdf.com/reader/full/flue-kit-guide 3/14

  TWIN PIPE FLUE SYSTEMS – Non condensing boilers

CE 0694  TA99E006.A0105 

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH 

Flue kit options kit B kit D -  - 

descriptions

horizontal double pipesflue kit systemwith intake / exhaust pipesD. 80/80

horizontal double pipesflue kit systemwith intake / exhaust pipesD. 80/80

- -

code 82046LP 82053LP - -

flue kits → 

models ↓ max. flue length

(metres) max. flue length

(metres) 

RS 20 E 30RS 24 E 30

RS 30 E 30

RBS 20 E 30

RBS 24 30

RSF 20 E 30

RSF 24 E 30

RSF 30 E 30

RMAS 20 E 30

RMAS 24 E 30RMAS 30 E 30

RS 21 E/3S 32

RSF 21 E/3S 32

RMAS 21 E/3S 32

RBA CS 24 E 26

RBA CS 30 26

RBA CS 100 E 30

RBA CS 30/100 30

SF 14 30

Note: For the double pipes flue kit system, the maximum length of the exhaust pipe must not exceed 2/3 of the total

permitted length as shown in the above table.

7/27/2019 Flue Kit Guide

http://slidepdf.com/reader/full/flue-kit-guide 4/14

  FLUE KIT SYSTEMS FOR CONDENSING BOILERS

CE 0694  TA99E006.A0105 

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH 

Flue kit options kit H kit K kit V

descriptions

horizontal double pipesflue kit systemwith intake / exhaust pipesD. 80/80 in pps

horizontal-coaxial flue kitsystem with intake /exhaust pipes D. 100/60in pps

vertical-coaxial fluekit system withintake / exhaustpipes D. 100/60 inpps

code 82086LA 82087LA 82091LA

flue kits → 

models↓

 

max. flue length * 

(metres) 

max. flue length 

(metres) 

max. flue length 

(metres) 

RK 25 50  5  5 RKR 25 50  5  5 RKA 25 50  5  5 RKA 100 50  5  5 

Note:  Horizontal double pipes flue kit system with intake / exhaust pipes ø60/60 in pps:

max. flue length (metres): 30 

Note: For the double pipes flue kit system, the maximum length of the exhaust pipe must not exceed 2/3 of the total

permitted length as shown in the above table.

7/27/2019 Flue Kit Guide

http://slidepdf.com/reader/full/flue-kit-guide 5/14

  Flue Kit Systems for EXTERNAL INSTALLATION boilers – Non condensing boilers

CE 0694  TA99E006.A0105 

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH 

Flue kit options kit A Rain kit E kit F kit BOX

descriptions

horizontal-coaxialflue kit systemwith intake /exhaust pipes D.100/60

single pipe flue kit systemfor external installationwith exhaust pipe D. 80

single vertical pipeflue kit system for external installationwith exhaust pipeD. 80 

single pipe flue kitsystem for externalinstallation with exhaustpipe D. 80 

code 82054LP 82052LP 82072LP 82095LP

flue kits → 

models ↓ 

max. flue length 

(metres) 

max. flue length 

(metres) 

max. flue length 

(metres) max. flue length 

(metres) RAIN 30 E/R 3 15 3

RBS 20 E / Midyrain 15 3

RAIN 20 E 3 15 3

RAIN 24 E 3 15 3

RSF 20 E / Slimbox 15 

RSF 24 E / Slimbox 15 

RSF 30 E / Slimbox 15 

RBS 20 E / Midybox 15 

RMAS 20 E / Plusbox 15 RMAS 24 E / Maxibox 15 

RMAS 30 E / Superbox 15 

7/27/2019 Flue Kit Guide

http://slidepdf.com/reader/full/flue-kit-guide 6/14

  ACCESSORIES for COAXIAL FLUE SYSTEMS – Non condensing boilers

CE 0694  TA99E006.A0105 

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH 

drawingequallength

Leqcode description kit A

kit ARain

kit ATelescopic

kit C kit G

- 27041LA roofing slate • 

1.5 27051LA 90° flue bend D.125/80 extension kit • 

0.5 27057LA 45° flue bend D.125/80 extension kit • 

- 27069LA Roof slate for flat type roof  • 

- 64052LP adjustable diaphragm D.100 •  •  •  •  • 

0.8 82009LP 90° flue bend D.100/60 extension kit •  •  • 

0.5 82027LP 45° flue bend D.10060 extension kit •  •  • 

- 82031LP D.100/95 clamp+rubber seal kit •  •  • 

1 82036LPhorizontal flue "KIT A" extensionD.100/60 1 mt. MF

•  •  • 

- 82042LP D.100/100 clamp+rubber seal kit •  •  •  • 

0.4 82045LP vertical connection kit D.100/60 w/testpoint • 

1 82060LPvertical flue “KIT C” extension D.118/80- 1 mt. • 

1 82082LA 1 mt. extension D.125/80 • 

7/27/2019 Flue Kit Guide

http://slidepdf.com/reader/full/flue-kit-guide 7/14

  ACCESSORIES for TWIN Pipe system – Non condensing boilers

CE 0694  TA99E006.A0105 

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH 

drawingequallength

Leqcode description kit B kit BOX kit D kit E kit F

0.5 27018LA water trap connection D.80 w/test point • 

- 52530LP D.80 intake/exhaust connection kit • 

- 52561LP D.80 intake/exhaust connection “ KIT E” •  •  •  • 

- 64053LP adjustable diaphragm D.80 •  •  • 

1.5 82032LP90° flue bend D. 80 m/f kit wide radiusno test point • 

1.2 82033LP 45° flue bend D.80 MF extension kit • 

- 82034LP D.80 clamp + rubber seal kit •  •  •  •  • 

0.8 82035LP flue "KIT B" extension D.80 1 mt. MF •  •  • 

3 82037LP 90° flue bend D.80 MF extension kit •  •  • 

- 82044LP90° flue bend D.80 MF wide radiusw/test point •  •  • 

7/27/2019 Flue Kit Guide

http://slidepdf.com/reader/full/flue-kit-guide 8/14

  ACCESSORIES FOR CONDENSING BOILER FLUE KIT SYSTEMS 

CE 0694  TA99E006.A0105 

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH 

drawingequal length

Leqcode description kit H kit K kit V

27047LA 90° flue bend D.60 MF extension kit • 

27048LA 45° flue bend D.60 MF extension kit  • 

27049LA kit "T" connection D.60 MF • 

27050LA exhaust / intake vertical connection D.80 • 

27053LA 45° flue bend D.60/100 MF extension •  • 

27054LA 90° flue bend D.100/60 MF extension •  • 

27055LA 90° flue bend D.80 FF extension kit • 

27056LA 45° flue bend D.80 MF extension kit • 

27057LA 45° flue bend D.100/60 MF •  • 

27058LA roof slate (for flat type roof) • 

27059LA roof slate (for slope type roof) • 

27060LA coaxial connection D.100/60 MF for kit V • 

7/27/2019 Flue Kit Guide

http://slidepdf.com/reader/full/flue-kit-guide 9/14

  ACCESSORIES FOR CONDENSING BOILER FLUE KIT SYSTEMS 

CE 0694  TA99E006.A0105 

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH 

drawingequal length

Leqcode description kit H kit K kit V

52530LP exhaust / intake vertical connection D.80 • 

82083LA condensation trap D.60 • 

82084LA "KIT K“ 1 mt. extension D.100/60 MF •  • 

82085LP "KIT H“ 1 mt. extension D.60 MF • 

82088LA kit D.80/60 adapter  • 

82090LA "KIT H” 1 mt. extension D. 80 MF • 

7/27/2019 Flue Kit Guide

http://slidepdf.com/reader/full/flue-kit-guide 10/14

  PARTS ONLY for COAXIAL FLUE SYSTEMS – Non condensing boilers

CE 0694  TA99E006.A0105 

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH 

drawingequal length

Leqcode Description kit A

kit ARain

kit ATelescopic

kit C

 

0.8 27002LA 90° flue bend D.100/60 for extension •  •  • 

0.1 27011LA vertical connection D.100x68 for "KIT ARAIN" • 

0.1 27014LA flange D.100 for vertical connection •  • 

0.5 27029LA 45° flue bend D.100/60 •  •  • 

0.4 27035LAvertical coaxial connection D.100/60 w/testpoint •  • 

1.5 27037LAvertical coaxial connection D.118/80 MFw/test point • 

0.5 27038LAflue bend D.100/60 w/test point for "KIT ARAIN" • 

0.8 27042LA flue bend D.100/60 w/test point and flange • 

- 38502LA fixing clamp D.100 •  • 

- 43012LA external rubber wall seal D.100 •  • 

- 43056LA rubber collar D.100/95 pipe-bend •  • 

- 43066LA rubber collar D.100/100 pipe-pipe •  • 

- 43085LA neoprene sealing gasket D.100 (128x98) •  •  • 

- 43111LA rubber collar D.95/95 bend-bend coaxial •  • 

- 54002LA internal/external flue pipes separator  •  • 

- 64052LP adjustable diaphragm D.100 •  •  •  • 

2 80010LA flue terminal D.60.5 •  • 

7/27/2019 Flue Kit Guide

http://slidepdf.com/reader/full/flue-kit-guide 11/14

  PARTS ONLY for COAXIAL FLUE SYSTEMS – Non condensing boilers

CE 0694  TA99E006.A0105 

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH 

drawingequal length

Leqcode Description kit A

kit ARain

kit ATelescopic

kit C

 1 82001LP inner flue pipe D.60x920 aluminium •  • 

1 82002LP pipe D.60x1000 MF white for extension •  • 

1 82004LP pipe D.100x905 white w/edge for "KIT A" •  • 

1 82005LP pipe D.100x1000 MF white for extension •  • 

1 82006LPpipe D.118x1000 MF aluminium for "KIT C"extension • 

1 82017LP pipe D.60x1000 MF aluminium for extension • 

82018LPpipe D.80x1000 MF aluminium for "KIT C"extension • 

1 82019LP inner flue pipe D. 60x920 white for "KIT A"

7/27/2019 Flue Kit Guide

http://slidepdf.com/reader/full/flue-kit-guide 12/14

  PARTS for TWIN PIPE FLUE SYSTEMS – Non condensing boilers

CE 0694  TA99E006.A0105 

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH 

drawingequal lenght

Leqcode description kit B kit D kit E kit F

 

1.2 27028LA 45° flue bend D. 80 MF •  •  •  • 

1.5 27030LA 90° flue bend D.80 MF wide radius •  •  •  • 

- 27033LA vertical connection D.80 exhaust w/test point •  •  •  • 

- 27034LA vertical connection D.80 intake w/test point •  •  •  • 

1.2 27036LA 90° flue bend D.80 MF w/test point •  •  •  • 

1.5 27039LA 90° flue bend D.80 MF wide radius w/test point •  •  •  • 

- 38505LA fixing clamp D.80 •  •  •  • 

- 43023LA rubber collar D.80 •  • 

- 43031LA exhaust fan D.54 rubber seal •  • 

- 43057LA red washer D.80 •  •  •  • 

- 43088LA noprene sealing gasket D.80 (98x80) •  •  •  • 

- 43090LA external rubber wall seal D.80 for "KIT B" •  •  • 

- 43102LA external rubber seal rain protection for "KIT E" • 

- 43103LA rubber washer D.60 double edge • 

- 43104LA vertical connection D.80 exhaust for "KIT E" • 

- 43105LA Rubber collar D. 80 double edge •  •  • 

7/27/2019 Flue Kit Guide

http://slidepdf.com/reader/full/flue-kit-guide 13/14

  PARTS for TWIN PIPE FLUE SYSTEMS – Non condensing boilers

CE 0694  TA99E006.A0105 

Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH 

drawingequal lenght

Leqcode description kit B kit D kit E kit F

 

0.15 44509LA Metallic grid for "KIT E" • 

- 64053LP adjustable diaphragm D.80 •  •  •  • 

- 80003LA stainless steel terminal D.80 •  • 

- 80004LA air intake flue terminal D.80 nylon •  • 

- 80005LA flue terminal D.80 for outdoor installation •  • 

- 80007LA flue terminal D.80 exhaust GB •  • 

- 80009LA terminale D.80 antivento •  •  • 

1 82003LA pipe D.80 x 1000 mm MF white for extension •  •  •  • 

1 82073LP pipe D.80 x 700 w/inspection • 

7/27/2019 Flue Kit Guide

http://slidepdf.com/reader/full/flue-kit-guide 14/14

 

RADIANT BRUCIATORI s.p.a.Via Pantanelli, 164/166 - 61025 Loc. Montelabbate (PU)Tel. +39 0721 9079.1 • fax. +39 0721 9079279e-mail: tecnico@radiant • Internet: http://www.radiant.it

DATI TECNICI E MISURE NON SONO IMPEGNATIVE. LA DITTA SI RISERVA IL DIRITTO DIEVENTUALI VARIAZIONI SENZA L'OBBLIGO DI PREAVVISO. DECLINIAMO OGNIRESPONSABILITÀ PER EVENTUALI INESATTEZZE CONTENUTE NEL PRESENTE OPUSCOLO,SE DOVUTE AD ERRORI DI STAMPA O DI TRASCRIZIONE. E+OETUTTI I DIRITTI SONO RISERVATI. NESSUNA PARTE DI QUESTO DOCUMENTO PUÒ ESSERERIPRODOTTA, MEMORIZZATA IN SISTEMI D’ARCHIVIO, O TRASMESSA IN QUALSIASI FORMAO MEZZO ELETTRONICO, MECCANICO, FOTOCOPIA, REGISTRAZIONE O ALTRI, SENZA LAPREVENTIVA AUTORIZZAZIONE SCRITTA DELLA DITTA.

TA01E006 A0105