Technical BulletinHot-tap Insertion and Removal
A “hot-tap” meter means that the device can beput into and taken it out of the pipe without shuttingoff pressure or getting all wet. SeaMetrics' IP andTX 115 and 215 models are hot-tap meters. Thepictures below show removal and replacement ina pressurized pipe.
1. Loosen compression fitting 2. Retract flow meter
4. Remove meter3. Close valve
TB-0009-12011 of 2
The process for originally cutting a hole in the pipewithout leaking water is not shown. This is a littlemore involved, and requires a special hot-tap drillmachine. In many cases, the pipe is shut down forthe original installation, making this stepunneccesary.
5. Examine/service meter 6. Replace meter
7. Open valve 8. Adjust meter, tighten nut