![Page 1: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/1.jpg)
Fitness for Service Evaluation of Hydrotest Exemption According to API 653
![Page 2: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/2.jpg)
Hydrostatic Testing – Why?
• To prevent risk of brittle fracture in service
• To prevent product leaks
• To check tank settlement
• Shows the tank is suitable for continued service
![Page 3: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/3.jpg)
Brittle Fracture
• Dependent on • Material toughness • Temperature • Stress level • Crack like defect
• Examples
• Fawley storage tank, UK in 1952 • Pittsburgh storage tank, USA in 1988
Brittle Fracture
Crack-like defect
![Page 4: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/4.jpg)
Fawley storage tank, UK in 1952
• 42 m diameter
• During hydrostatic test
• Fracture tougness lowered after welding
![Page 5: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/5.jpg)
Pittsburgh storage tank, USA in 1988
• Tank was moved
• Reassembled with no inspection
• 14000 m3 Diesel oil spilled
• 3000 m3 into the river
![Page 6: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/6.jpg)
Major Alteration or Major Repair
• Nozzle in shell larger than NPS 12
• Replace or add shell plate exceeding 12 in.
• Remove or replace annular plate material
• Replacement of more than 12 in. vertical weld
![Page 7: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/7.jpg)
Major Alteration or Major Repair
• Replacement of more than 12 in. of radial weld in annular plate
• Installation of new bottom
• Replacement of shell to bottom weld
• Jacking a tank shell
![Page 8: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/8.jpg)
Hydrostatic Test Exemption Engineer Approval and Owner Authorization
12.3.2.2
Fitness for Service Evaluation 12.3.2.1.b/12.3.2.7
Hydrotest Exemption
Appropriate Following Parts 12.3.2.1.a
Shell Repair 12.3.2.3
Bottom Repair within Critical Zone 12.3.2.4
Shell-to-bottom Weld Repair 12.3.2.5
Minor Shell Jacking 12.3.2.6
Hydrotest Exemption
![Page 9: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/9.jpg)
12.3.2.7 Fitness for Service Evaluation
Fitness for Service
Mechanical Finite Element Modelling
Stress Analysis Engineering Critical Assessment
Inspection Tank Dimensions
Filling Height Design Temperature
Thickness Measurements NDT Weld Acceptance Limit
Materials WPQR/WPS
Weld Specimens Old-to-new Fracture Toughness (Charpy V)
Material Properties Test
![Page 10: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/10.jpg)
NDT Acceptance Limit
• Undercut acc. to ISO 5817 • Quality level D, C or B
• D) h ≤ 0.2t, but max. 1 mm
• C) h ≤ 0.1t, but max. 0.5 mm
• B) h ≤ 0.05t, but max. 0.5 mm
![Page 11: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/11.jpg)
Weld Specimens
• Piece of existing tank material
• Piece of new tank material
• Welded with new WPS/WPQR
![Page 12: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/12.jpg)
Charpy V Specimens
• Charpy V Specimens for estimating Impact energy (and fracture toughness)
• Tensile tests may be needed to verify mechanical properties
![Page 13: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/13.jpg)
Charpy Specimen Locations
• Sets of three Charpy V specimens • Weld metal • HAZ, • +2 mm from HAZ • +5 mm from HAZ
![Page 14: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/14.jpg)
Obtain Charpy Impact strength
![Page 15: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/15.jpg)
Obtain Kmat Fracture Toughness from Charpy Tests
![Page 16: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/16.jpg)
Finite Element Model
• Finite element model is based on • Tank dimensions • Inspection reports • Filling height
• Stress analysis
• Determine membrane and bending stresses
![Page 17: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/17.jpg)
Tank Deformation
• Tank bottom lifts from the ground
• Scale x50
![Page 18: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/18.jpg)
Stress Analysis
• Axial Stress
• High stress at weld toe to shell
• Primarily bending stresses
![Page 19: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/19.jpg)
Examples of FE Models
![Page 20: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/20.jpg)
Engineering Critical Assessment
• Stress level from FE analysis
• Fracture toughness from material test
• Partial safety factors
• Determine critical flaw size
![Page 21: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/21.jpg)
Failure Assessment Diagram
![Page 22: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/22.jpg)
Critical Flaw Size
![Page 23: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/23.jpg)
Fitness for Service Evaluation
• Compare critical flaw size with NDT acceptance limits
If critical flaw size is larger than NDT acceptance limit, hydrostatic test is not required
![Page 24: Fitness for Service Evaluation of Hydrotest Exemptiontankref.dk/onewebmedia/5. Force - Fitness for Service Evaluation of... · Fitness for Service Evaluation of Hydrotest ... Hydrostatic](https://reader034.fdocuments.in/reader034/viewer/2022051205/5ad2e2407f8b9a0f198ceb49/html5/thumbnails/24.jpg)
Further information at forcetechnology.com