Firefly Fluorescence Imaging for da Vinci Si - Delec
Transcript of Firefly Fluorescence Imaging for da Vinci Si - Delec
Note: Refer to package insert for more information on indications for use.
For more information, please call Intuitive Surgical Customer Service at 1-800-876-1310 US • +800 0 821 20 20 Europe • www.intuitivesurgical.com
Firefly™ Fluorescence Imaging for da Vinci ® Si
™
Real-time anatomy identification using near-infrared guidance
Features Potential Benefits
Real-time near-infrared guidance through visualization of injectable fluorescence dye
Enables enhanced visualization capabilities for:• Vessel identification• Soft tissue perfusion
Interface allows efficient toggling between normal illumination and fluorescence imaging modes
Allows real-time identification of anatomy in fluorescence imaging mode from the Si surgeon console, in 3DHD quality
Illuminator utilizes LED technology Minimizes downtime, operating expense associated with lamp replacement
Ordering Informationda Vinci Si P/N Part Description Compatible With:
380993 Firefly Fluorescence Imaging Upgrade Kit, da Vinci Si Existing Si vision components
Upgrade Kit Contains:
• 1 Camera Head with Cable, Fluorescence - P/N: 381103 Existing Si illuminator and endoscopes
• 1 Endoscope, 12 mm dia., 0º, Fluorescence - P/N: 370892Existing Si illuminator and camera heads
• 1 Endoscope, 12 mm dia., 30º, Fluorescence - P/N: 370893
• 1 Illuminator, Fluorescence Existing Si camera heads and endoscopes
Fluorescence Dye Ordering InformationInjectable dye for use in Firefly fluorescence imaging with the da Vinci Si Surgical System
da Vinci Si P/N Part Description
950156 Fluorescence Imaging Pack (Indocyanine Green*)
Pack Contains: • 6 procedure vials of indocyanine green with aqueous solvent• 6 procedure kits containing sterile supplies to facilitate reconstitution and intravascular
administration
Normal 3DHD Illumination mode (view of renal hilum) Vessel identification in fluorescence imaging mode (view of renal hilum)
PN874812RevC-7/12
*The above ICG ordering information is for US ONLY; ICG is not available through ISI for outside-the-US markets.
Firefly™ Fluorescence Imaging is FDA-cleared for visual assessment of vessels, blood flow and related tissue perfusion using near-infrared imaging. Intuitive's ICG packs are FDA-cleared for use in combination with the fluorescence-capable da Vinci Si HD vision system and Firefly integrated hardware. Intuitive-distributed ICG contains necessary directions for use for effective use of ICG with the Firefly Fluorescence Imaging. Using generic ICG with Firefly Fluorescence Imaging is considered off-label. I As with any surgery, individual results may vary, as surgery is patient- and procedure- specific. ©2012 Intuitive Surgical, Inc. All rights reserved. Intuitive®, Intuitive Surgical®, da Vinci®, da Vinci
® S™, da Vinci
® Si™, InSite® and EndoWrist® are trademarks or registered trade-
marks of Intuitive Surgical, Inc. All other mentioned company names and products are used for identification purposes only and may be trademarks and properties of their respective owners. PN 874812 Rev C 7/12
For more information, please call Intuitive Surgical Customer Service at 1-800-876-1310 US • +800 0 821 20 20 Europe • www.intuitivesurgical.com
Redesigned camera head optics have been optimized to capture a fluorescence signal
Console controls allow easy switching between normal illumination, fluorescence imaging modes
Fluorescence imaging LED illuminator emits a laser to excite fluorescence dye in situ
New 0º and 30º 12 mm endoscopes with updated optics can receive and transmit a fluorescence imaging signal
Firefly ™ Fluorescence Imaging with da Vinci® Si
™
Hardware Upgrade Overview