Enhanced Smoke Detection System with
EMERGENCY LIGHTSand
REMOTE MESSAGING SYSTEM
Submitted By:
09061720906175090618209061840906187
Objective
how c
an w
e
STOP
thes
e?
Reasons of Major Losses
• Lower quality of Fire Detection System• Communication gap among the buildings and Nearest Fire
Service Stations• Lack of Fire Extinguishers• Absence of Emergency Systems
Project Overview:
• A remote SMS system to communicate immediately with nearest fire stations, local PS, local hospitals and other necessary places
• A emergency light system in case of power failure
Required chips
• ATMEGA32A• LM35 (Heat Sensor)• LM324 (Op-Amp)• 7404 (Not Gate)• SIM900 (GSM Module)
Block Diagram (Emergency Light)
Main Line
220-6V XFR
Charge/Discharge
DC Battery
Emergency Light
Block Diagram (Remote SMS)
5V Vcc
LM35 (Heat Sensor)
Voltage Comparator
ATMEGA32A
GSM Module
Circuit Diagram
Remote SMS System
• The GSM module (SIM 900) is interfaced with ATMEGA32A in the total system
Sensing The Fire
• A heat sensor (LM35) is used to detect room temperature• A comparator circuit is used to compare the output voltage of
LM35 with a given reference voltage• If the output is above certain level, it takes the decision that a fire
incident has occurred
SOS
As the fire has been detected, the module will automatically send SMS to necessary persons and places
Emergency Light System
Smok
e
Shor
t Circ
uit
Sabo
tage
Faulte
d Equ
ipm
ent
Faulte
d Pr
oduc
iton
Flam
able
Raw
Mat
teria
ls
Misce
llane
ous
0
10
20
30
40
Series 1
Column2 Series 1Column1Column2
Emergency Light System
• Powered by a rechargeable DC battery• If the main power goes off, the emergency lights
automatically turn on• Other times, the battery is being charged and kept nearly
100% charged
Cost Estimation
• GSM Module- Tk. 2300• Transformer (220-6V)- Tk. 65• Microchip (ATMEGA32A)- Tk. 200• Heat Sensor (LM35)- Tk. 45• DC Battery (2 pcs)- Tk.50• Miscellaneous- Tk. 130
• Total Cost- Tk. 2790
In case of MASS PRODUCTION, total cost can be decreased to Tk. 2000 (estimated)
Limitations
• LM35 is very sensitive, so in case of other temperature arising incidents, the system can turn on.
• The output of LM35 is in mV range (10 mV/◦C), so minor noise can activate the system
Future Development
• Inclusion of fire alarm• Automated Fire Extinguishers in sensitive places
Cautions
• Both GSM Module and Microchips are voltage sensitive, minimum increase can harm these devices
• GSM module is temperature sensitive• Total system (except the LM35) should be installed in a
neutral place
Thank you
Save life, save property, get your own device now
Contact
Antar, Didar, Pradip, Siam, Shantonu4008, Sher-e Bangla Hall, BUET