Transcript of FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM
![Page 1: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/1.jpg)
FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY
USING GSM
BY
P. SAIKIRAN(12631A0469)M.SOUJANYA(12631A0488)S.VEERANNA(12631A04A7)N. SRINATH(12631A0496)
Under the Guidance of S. BALAIAHM.Tech,(Ph.D)
Asso. Professor
![Page 2: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/2.jpg)
Reasons for choosing this project
Objective of this project is to control home/industry electrical appliances and fire detection from remote area.
There are many home wireless based devices for controlling processes, but they are more expensive.
Increase in technology
![Page 3: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/3.jpg)
AIM
The main aim of this project is to develop a system based on Embedded micro controller ,which is used for controlling electrical appliances in home or industry and fire detection using GSM.
![Page 4: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/4.jpg)
CURRENT SCENARIO
The healthy person is able to sense multiple aspects of a fire including the heat, flames.
For this reason, most fire alarm systems are designed with one or more manual alarm activation devices to be used by the person who discovers a fire.
In this system we can remotely control the devices.
![Page 5: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/5.jpg)
PROPOSED SCENARIO
we are going to not only control the devices but also providing fire sensor for fire detection and effective control of electrical power to the apparatus, machines from remote place.
Whenever a fire accident happens in the home or industry the fire sensor senses the fire
This is the project make use of modern communication technologies and it is used in emergencies.
![Page 6: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/6.jpg)
BLOCK DIAGRAM
![Page 7: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/7.jpg)
HARDWARE & SOFTWARE TOOLS
Microcontroller AT89S52GSM modemMAX232Temperature sensor (LM35)TRIACLCDKeil complierProteus
![Page 8: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/8.jpg)
What is AT89S52 ? 8051 based full static CMOS controller 32 I/O lines Three 16-bit timers/counters 8-interrupt sources 2 DPTRs 8k flash memory 256 bytes on-chip RAM
![Page 9: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/9.jpg)
Features of 89S52
8K bytes of In-system programmable flash memory 4v to 5.5v operating range Fully static operation: 0Hz to 33MHz Low power idle & power down modes Fast programming time
![Page 10: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/10.jpg)
PIN DIAGRAM OF AT89S52
![Page 11: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/11.jpg)
What is GSM Modem ?
Accepts a SIM card & operates over a subscription Internet connectivity Transmitting & Receiving SMS or MMS messages Narrowband TDMA technique for Transmitting
signals It has an ability to carry 64Kbps to 120Mbps of data
rates
![Page 12: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/12.jpg)
Some GSM Technologies are
2.5G Technologies GPRS & EDGE
3G Technologies WCDMA,UMTS,HSDPA & HSUPA
![Page 13: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/13.jpg)
Features of GSM
Highly reliable Simple to use & low costSMS based remote control & alertsSecuritySensor monitoring
![Page 14: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/14.jpg)
What is MAX 232 ?
RS 232Serial communication dataConnect microcontroller to other devices i.e., PC,GSM,GPRS,GPS8-bit data transfer at a time
![Page 15: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/15.jpg)
What is LM35 ?
Pins : Vcc , GND , output To measure temperature with electrical
output, proportional to temperature in oCTemperature range -55 to 150 oCUsing conversion factor find output
interms of oCTemperature ( oC) = Vout * (100 oC/V)
![Page 16: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/16.jpg)
TRIAC
• The TRIAC is a three terminal semiconductor device for controlling current.
• It gains its name from the term triode for alternating current.
• TRIAC is a bidirectional device.
![Page 17: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/17.jpg)
What is LCD ?
It displays alphabets, Greek letters, punctuation marks, mathematical symbols etc
Low price Instead of LED we LCD because In LEDs limited numbers & characters used And for easy programming
![Page 18: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/18.jpg)
POWER SUPPLY
LED
LED
1k
- +
IN4007 * 4
GND
9-0-9Vac/1Amp
1000uF/35V
7812
POWER SUPPLY
+5V
+12V230VAC50Hz 2.2k
7805
![Page 19: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/19.jpg)
What is keil compiler ?
Is used to write ,compile ,and debug embedded programs
It encapsulates A project manager A make facility Tool configuration Editor A powerful debugger
![Page 20: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/20.jpg)
WORKING PRINCIPLE
At the transmitter side, the user sends an SMS to the GSM modem using AT commands indicating which device is to be controlled.
At the receiver side, Microcontroller controls the devices through TRIAC’s depending on the code received by the GSM modem.
When Fire occurs then the load is going to switch OFF automatically and information send to the user through the SMS.
![Page 21: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/21.jpg)
ADVANTAGES
Easy to constructMore secureLess complexity
![Page 22: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/22.jpg)
DISADVANTAGES
If the microcontroller fails, then it leads to catastrophe.
User can make mistake while typing the message format.
![Page 23: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/23.jpg)
APPLICATIONS
It is useful in time maintenance applications.Remote device control Detection of flame, gas breaks and water spills.To run any electrical and electronic appliances easily. It is used in electrical sub stations to switch ON/OFF
the power supply without using man power.
![Page 24: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/24.jpg)
CONCLUSION
We develop a general purpose electronic circuit design that can control and monitor a variety of home appliances and fire sensor with interface that can be plugged into GSM modem.
The system can automatically switch ON and OFF the devices remotely using SMS.
![Page 25: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/25.jpg)
FUTURE SCOPE
Right now we have designed the project for control of two devices but it can be designed for more number of devices.
It can be further expanded with a voice interactive system facility.
A feedback system can also be included which provides the state of a device (whether it is on/off) to the remote user.
![Page 26: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/26.jpg)
THANK YOU
![Page 27: FIRE DETECTION AND ELETRICAL POWER ON/OFF CONTROL IN HOME/INDUSTRY USING GSM](https://reader035.fdocuments.in/reader035/viewer/2022062823/5872e45c1a28abfa548b5a7f/html5/thumbnails/27.jpg)
Quires..?