FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat,...

29
6WIDE BASE COAT, FABRIC AND BASE COAT COMPONENTS continuous cleat FLAT PROFILE PRE-FINISHED METAL EDGE FLASHING ATTACHED WITH COATED SCREWS @ 3O.C. STAGGERED 12WIDE BASE COAT AND BASE COAT COMPONENTS BASE COAT, FABRIC, AND BASE COAT COMPONENTS FROM FIELD OF ROOF. 12" 6" FINISH COAT COMPONENT OVER ENTIRE ROOF (COLOR AS SPECIFIED) NOTES: 1. ALL FLASHING SHALL BE DESIGNED FOR THE APPLICABLE ROOF CONDITIONS. METAL THICKNESS, FASTENERS, AND LAPPING SHALL BE AS SPECIFIED BY THE ROOF DESIGNER. 2. REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR SPECIFIC EXECUTION REQUIREMENTS. WALL ROOF DECKING INSULATION 3. FLUID APPLIED RESTORATION SYSTEM BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS 4. BASE COAT COMBINED COVERAGE (2 COATS) AT minimum rate as directed in the specification. 5. EACH FINISH COAT SHALL BE APPLIED AT THE PRODUCT DATA SHEET RECOMMENDATIONS. ALLOW TO DRY BETWEEN COATS. 6. PRIMING REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS note: NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT www.tropicalroofingproducts.com STANDARD DRIP EDGE DETAIL DETAIL NO : DATE : 12-13-16 FLUID APPLIED RESTORATION COATING SYSTEM 1 disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Transcript of FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat,...

Page 1: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

6” WIDE BASE COAT,

FABRIC AND BASE COAT

COMPONENTS

continuous cleat

FLAT PROFILE

PRE-FINISHED METAL EDGE

FLASHING ATTACHED WITH

COATED SCREWS

@ 3” O.C. STAGGERED

12” WIDE BASE COAT AND BASE COAT

COMPONENTS

BASE COAT, FABRIC, AND BASE COAT

COMPONENTS FROM FIELD OF ROOF.

12"

6"

FINISH COAT COMPONENT OVER ENTIRE

ROOF (COLOR AS SPECIFIED)

NOTES:

1. ALL FLASHING SHALL BE DESIGNED FOR THE APPLICABLE ROOF CONDITIONS. METAL THICKNESS, FASTENERS, AND LAPPING

SHALL BE AS SPECIFIED BY THE ROOF DESIGNER.

2. REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR SPECIFIC EXECUTION REQUIREMENTS.

WALL

ROOF DECKING

INSULATION

3. FLUID APPLIED RESTORATION SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS

4. BASE COAT – COMBINED COVERAGE (2 COATS) AT minimum rate as directed in the specification.

5. EACH FINISH COAT SHALL BE APPLIED AT THE PRODUCT DATA SHEET RECOMMENDATIONS. ALLOW TO DRY BETWEEN COATS.

6. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS

note: NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID

APPLIED SYSTEM GUIDE SPECIFICATIONS AT www.tropicalroofingproducts.com

STANDARD DRIP EDGE DETAIL DETAIL NO :

DATE :

12-13-16FLUID APPLIED RESTORATION COATING SYSTEM

1disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 2: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

12"6” WIDE BASE COAT,

FABRIC AND BASE COAT

COMPONENTS

6"

METAL GUTTER AND

SUPPORT BRACKETS

BASE COAT, FABRIC, AND BASE COAT

COMPONENTS

BASE COAT, FABRIC, AND BASE COAT

COMPONENTS FROM FIELD OF ROOF.

FLAT PROFILE

PREFINISHED METAL EDGE

FLASHING ATTACHED WITH

COATED SCREWS @ 3” O.C.

STAGGERED

continuous cleat

FINISH COAT COMPONENT OVER ENTIRE

ROOF (COLOR AS SPECIFIED)

WALL

ROOF DECKING

INSULATION

NOTES:

1. ALL FLASHING SHALL BE DESIGNED FOR THE APPLICABLE ROOF CONDITIONS. METAL THICKNESS, FASTENERS, AND LAPPING SHALL BE

AS SPECIFIED BY THE ROOF DESIGNER.

2. REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR SPECIFIC EXECUTION REQUIREMENTS.

3. FLUID APPLIED RESTORATION SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS

4. BASE COAT – COMBINED COVERAGE (2 COATS) AT minimum rate as directed in the specification.

5. EACH FINISH COAT SHALL BE APPLIED AT THE PRODUCT DATA SHEET RECOMMENDATIONS. ALLOW TO DRY BETWEEN COATS.

6. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS

note: NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

GUTTER WITH STANDARD DRIP EDGE DETAIL DETAIL NO :

DATE :

12-13-16FLUID APPLIED RESTORATION COATING SYSTEM

2disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 3: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

wall

concrete

roof deck

8"

base coat, 12" fabric, and

base coat components

cover entire

exposed edge

note: STRUCTURAL CONCRETE MUST BE

CURED AT LEAST 28 DAYS. REFER TO

CONCRETE MANUFACTURER CURING TIME.

NOTES:

1. ALL FLASHING SHALL BE DESIGNED FOR THE

APPLICABLE ROOF CONDITIONS. METAL

THICKNESS, FASTENERS, AND LAPPING SHALL BE

AS SPECIFIED BY THE ROOF DESIGNER.

2. REFER TO TROPICAL ROOFING PRODUCTS

SPECIFICATIONS FOR SPECIFIC EXECUTION

REQUIREMENTS.

3. FLUID APPLIED RESTORATION SYSTEM – BASE

COAT, REINFORCED FABRIC, BASE COAT 2, AND

FINISH COAT COMPONENTS

4. BASE COAT – COMBINED COVERAGE (2 COATS) AT

minimum rate as directed in the specification.

5. EACH FINISH COAT SHALL BE APPLIED AT THE

PRODUCT DATA SHEET RECOMMENDATIONS. ALLOW

TO DRY BETWEEN COATS.

6. PRIMING – REFER TO TROPICAL ROOFING

PRODUCTS SPECIFICATIONS FOR DECK PRIMING

REQUIREMENTS

note: NOTE: FOR SPECIFIC PRODUCT

RECOMMENDATION REFER TO THE APPROPRIATE

FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

lap premium coat system

components from the roof

field over edge detail

fluid applied

restoration system:

base coat, 40"

fabric, base coat 2,

and finish coat over

entire roof deck.

DETAIL NO :

DATE :

12-13-16FLUID APPLIED RESTORATION COATING SYSTEM

3STANDARD STRUCTURAL CONCRETE ROOF DECK EDGE DETAIL

WITHOUT METAL DRIP EDGEdisclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 4: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

#932 fabric

deck joints

deck material with

staggered joints

6" minimum strip over

all deck joints

a. base coat over joint

b. reinforcing fabric

centered on joint

c. finish coat over fabric

DECK JOINT STRIPPING DETAIL

FINISH COAT COMPONENT,

COLOR AS SPECIFIED.

base coat 2

base coat

1. PREPARE ALL SURFACES IN

ACCORDANCE WITH THE

MANUFACTURER’S REQUIREMENTS.

2. ALL JOINTS SHALL BE TIGHT AND

STABLE. ALL FASTENERS SHALL BE

FLUSH WITH THE DECK.

3. FLUID APPLIED RESTORATION

SYSTEM – BASE COAT, REINFORCED

FABRIC, BASE COAT 2, AND FINISH

COAT COMPONENTS

4. BASE COAT – COMBINED

COVERAGE (2 COATS) AT MINIMUM

RATE as directed in the

specification.

5. EACH FINISH COAT SHALL BE APPLIED

AT THE PRODUCT DATA SHEET

RECOMMENDATIONS. ALLOW TO DRY

BETWEEN COATS.

6. PRIMING – REFER TO TROPICAL

ROOFING PRODUCTS SPECIFICATIONS

FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT

RECOMMENDATION REFER TO THE

APPROPRIATE FLUID APPLIED SYSTEM

GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

NOTES:

DECK JOINT STRIPPING DETAIL DETAIL NO :

DATE :

12-13-16FLUID APPLIED RESTORATION COATING SYSTEM

4disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 5: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

optional metal coping assembly

install entire system completely

over top of parapet

finish coat over entire roof

base coat, fabric, base coat

components

center 12" wide base coat, #932

fabric, and base coat components

over cant strip

existing roof deck and

insulation systems with or

without cant strip

roof drain shall be installed as

required by manufacturer

fluid applied coating system:

base coat, fabric, base coat

2, and finish coat

roof decking

tapered insulationbase coat, fabric, base coat

components

1. ROOFING MEMBRANE SHALL EXTEND UNDER THE ROOF DRAIN COMPRESSION CLAMPING RING.

2. SLOPE INSULATION TOWARDS DRAIN.

3. FLUID APPLIED RESTORATION SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS

4. BASE COAT – COMBINED COVERAGE (2 COATS) AT minimum rate as directed in the specification.

5. EACH FINISH COAT SHALL BE APPLIED AT THE PRODUCT DATA SHEET RECOMMENDATIONS. ALLOW TO DRY BETWEEN COATS.

6. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.

note: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

NOTES:

Drain clamp ring must be

removed, sealed add

reinstalled with #950/951

Mastic (acrylic) or #9100

Mastic (silicone)

STANDARD PARAPET & ROOF DRAIN DETAIL DETAIL NO :

DATE :

12-13-16FLUID APPLIED RESTORATION COATING SYSTEM

5disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 6: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

36"

mechanical exhaust fan unit

fan curb at minimum of 8" above

roof line

finish coat component over

entire roof. color as specified

fluid applied coating

system: base coat, fabric,

base coat 2, and finish coat

12" base coat, fabric and

base coat components

roof deck

construction

exhaust fan unit

mounted on roof

36"TYPICAL

NOTES:

1. THIS DETAIL IS A TYPICAL FLASHING DETAIL AT EXHAUST FANS FOR COOKING.

2. PREPARE THE ROOF SURFACE AS PER MANUFACTURER’S REQUIREMENTS PRIOR TO APPLICATION OF ROOF COATING.

3. REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR SPECIFIC EXECUTION REQUIREMENTS.

4. FLUID APPLIED RESTORATION COATING SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS

5. BASE COAT – COMBINED COVERAGE (2 COATS) AT minimum rate as directed in the specification.

6. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

section plan

TYPICAL EXHAUST FAN (FOR COOKING) FLASHING DETAIL

DETAIL NO :

DATE :

12-13-16FLUID APPLIED RESTORATION COATING SYSTEM

7disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 7: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

existing metal

roofingfinish coat. color

as specified.

metal primer

fluid applied coating system

overlap at gutter seams

vertical sides

GUTTER SEAM BOTTOM

SECTION

NOTES:

existing metal

gutter

1. PREPARE ALL GUTTER SURFACES AS REQUIRED BY FLUID APPLIED SYSTEM MANUFACTURER.

2. PRIME ENTIRE GUTTER WITH #960 METAL PRIMER @ 200 SF/GAL MINIMUM COVERAGE.

3. REMOVE LOOSE OR DAMAGES FASTENERS AND REPLACE WITH FASTENERS DESIGNED TO PENETRATE THE DECK AND SUPPORTING MEMBERS WITH NEOPRENE WASHERS

AT THE SCREW HEAD.

4. GUTTER CONFIGURATIONS MAY DIFFER FROM THE PROFILE INDICATED, BUT THE APPLICATION SHALL REMAIN SIMILAR.

5. FLUID APPLIED RESTORATION COATING SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS. ALL GUTTER SEAMS ARE TREATED

WITH BASE COAT AND 4” OR 6” FABRIC DEPENDING ON GUTTER PROFILE. ALL FASTENERS ARE TREATED With #950/951 (acrylic) or #9100 (silicone).

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT www.tropicalroofingproducts.com

gutter plan

TYPICAL GUTTER DETAIL DETAIL NO :

DATE :

12-13-16FLUID APPLIED RESTORATION COATING SYSTEM

8disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 8: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

deck fastener

install #950/951 MASTIC ON

ACRYLIC OR #9100 SILICONE MASTIC

over every screw

vertical seam base coat,

fabric(4", 6", or 8"), base

coat 2

finish coat. color

as specified

metal roof deck

horizontal seam base coat,

fabric (12") and base coat 2

NOTES:

1. PREPARE ALL ROOF SURFACES AS REQUIRED BY THE FLUID APPLIED SYSTEM MANUFACTURER.

2. IF RUST IS PRESENT, REMOVE SURFACE RUST AND PRIME WITH #960 METAL PRIMER @ coverage indicated in specification for acrylic

restoration systems. Silicone can be applied directly over metal after surface rust is removed.

3. REMOVE LOOSE OR DAMAGED FASTENERS AND REPLACE WITH FASTENERS DESIGNED TO PENETRATE THE DECK AND SUPPORTING MEMBERS

WITH NEOPRENE WASHERS AT THE SCREW HEAD.

4. DECK CONFIGURATIONS MAY DIFFER FROM THE DECK PROFILE INDICATED, BUT THE APPLICATION SHOULD REMAIN SIMILAR.

5. FLUID APPLIED RESTORATION COATING SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS. ALL

VERTICAL SEAMS ARE TREATED WITH BASE COAT AND 4”, 6” OR 8” FABRIC DEPENDING ON ROOF PROFILE. HORIZONTAL SEAMS ARE COVERED

WITH 12” FABRIC AND BASE COAT. ALL FASTENERS ARE TREATED WITH____

6. BASE COAT – COMBINED COVERAGE (2 COATS) AT MINIMUM RATE as directed in the specification.

7. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

DETAIL NO :

DATE :

12-13-16FLUID APPLIED RESTORATION COATING SYSTEM

TYPICAL METAL ROOF JOINT DETAIL9

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 9: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

3" 3"

MIN. MIN.

METAL ROOFING DECK

SECTION

NOTES:

1. PREPARE ALL ROOF SURFACES AS REQUIRED BY THE FLUID APPLIED SYSTEM MANUFACTURER

2. IF RUST IS PRESENT, PRIME ENTIRE ROOF WITH #960 PRIMER @ 200 SF/GAL MIN. COVERAGE

3. REMOVE LOOSE OR DAMAGED FASTENERS AND REPLACE WITH FASTENERS DESIGNED TO PENETRATE THE DECK AND SUPPORTING MEMBERS

WITH NEOPRENE WASHERS AT THE SCREW HEAD.

4. DECK CONFIGURATIONS MAY DIFFER FROM THE DECK PROFILE INDICATED, BUT THE APPLICATION SHALL REMAIN SIMILAR.

5. FLUID APPLIED RESTORATION COATING SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT COMPONENTS. ALL

VERTICAL SEAMS ARE TREATED WITH BASE COAT AND 4”, 6” OR 8” FABRIC DEPENDING ON ROOF PROFILE. HORIZONTAL SEAMS ARE COVERED

WITH 12” FABRIC AND BASE COAT. ALL FASTENERS ARE TREATED WITH #950/951 Mastic (acrylic) or #9100 Mastic (silicone)

6. BASE COAT – COMBINED COVERAGE (2 COATS) AT A MINIMUM RATE as directed in the specification.

7. EACH FINISH COAT SHALL BE APPLIED AT THE PRODUCT DATA SHEET RECOMMENDATIONS. ALLOW TO DRY BETWEEN COATS.

8. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING

REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

FINISH COAT COMPONENT,

COLOR AS SPECIFIED.

FINISH COAT COMPONENT OVER

ENTIRE ROOF (COLOR AS SPECIFIED)

10SECTION AT METAL PANEL SEAM DETAIL DETAIL NO :

DATE :

12-13-16FLUID APPLIED RESTORATION COATING SYSTEM

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 10: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

ROOF DRAIN. NOTE: ROOF

DRAIN SHALL BE INSTALLED AS

REQUIRED BY THE

MANUFACTURER.

ROOF DECKING

TAPERED

INSULATION

FLUID APPLIED

RESTORATION SYSTEM

– BASE

COAT, REINFORCED

FABRIC, BASE COAT 2,

AND FINISH COAT

COMPONENTS

NOTES:

1. ROOFING MEMBRANE SHALL

EXTEND UNDER THE ROOF DRAIN

COMPRESSION CLAMPING RING.

2. ALL DRAIN COMPONENTS SHALL

BE MADE OF CAST IRON UNLESS

APPROVED BY THE ROOF

MEMBRANE MANUFACTURER

TO USE ANOTHER MATERIAL.

3. SLOPE INSULATION TOWARDS

DRAIN.

4. FLUID APPLIED RESTORATION

SYSTEM – BASE COAT,

REINFORCED FABRIC, BASE COAT

AND FINISH COAT

COMPONENTS

5. BASE COAT – COMBINED

COVERAGE (2 COATS) AT A

MINIMUM RATE as directed in

the specification.

6. EACH FINISH COAT SHALL BE

APPLIED AT THE PRODUCT DATA

SHEET RECOMMENDATIONS. ALLOW

TO DRY BETWEEN COATS.

7. PRIMING – REFER TO TROPICAL

ROOFING PRODUCTS

SPECIFICATIONS FOR DECK

PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT

RECOMMENDATION REFER TO THE

APPROPRIATE FLUID APPLIED SYSTEM

GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

DETAIL NO :

DATE :

12-13-16FLUID APPLIED RESTORATION COATING SYSTEM

STANDARD ROOF DRAIN DETAIL11

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 11: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

ISOMETRIC VIEW

ROOF PARAPET

AT CORNER

12” X 12” REINFORCING

FABRIC, CUT TO FIT

INTO CORNER.

TAKE CUT UP TO TOP

OF CANT DIMENSION

TOP OF FABRIC

START OF CUT

REINFORCING FABRIC,

CUT TO FIT TIGHT AT

CANT AND TO

OVERLAP ON ROOF.

NOTES:

1. FLUID APPLIED RESTORATION

SYSTEM – BASE COAT, REINFORCED

FABRIC, BASE COAT 2, AND FINISH

COAT COMPONENTS

2. BASE COAT – COMBINED

COVERAGE (2 COATS) AT A MINIMUM

RATE as directed in the

specification.

3. EACH FINISH COAT SHALL BE APPLIED AT

THE PRODUCT DATA SHEET

RECOMMENDATIONS. ALLOW TO

DRY BETWEEN COATS.

4. PRIMING – REFER TO TROPICAL ROOFING

PRODUCTS SPECIFICATIONS FOR DECK

PRIMING

REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT

RECOMMENDATION REFER TO THE

APPROPRIATE FLUID APPLIED SYSTEM GUIDE

SPECIFICATIONS AT

www.tropicalroofingproducts.com

DETAIL NO :

DATE :

12-13-16FLUID APPLIED RESTORATION COATING SYSTEM

TYPICAL ROOF CANT (AT CORNER) FLASHING DETAIL 12

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 12: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

TERMINATION OF MEMBRANE FLASHING WILL VARY

SHEET METAL SCUPPER

SOLDERED/WELDED – SECURED TO WALL AND

DECK OR OPTIONAL WOOD BLOCKING.

FINISH COAT OVER ENTIRE ROOF. COLOR AS

SPECIFIED.

BASE COAT, FABRIC, BASE COAT COMPONENTS

ROOF DECK

SHEET METAL

CONDUCTOR HEAD

1” M

INIM

UM

BELOW S

CUP

PER

BOTTOM

INSTALL APPROPRIATE SEALANT AND

TOOL TO FACILITATE WATER RUNOFF.

fLUID APPLIED RESTORATION SYSTEM

BASE COAT, REINFORCED FABRIC,

BASE COAT 2, AND FINISH COAT

COMPONENTS

NOTES:

1. PRIMING – REFER TO TROPICAL ROOFING

PRODUCTS SPECIFICATIONS FOR DECK PRIMING

REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION

REFER TO THE APPROPRIATE FLUID APPLIED

SYSTEM GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

#950/951 Mastic

(acrylic) or #9100

Mastic (silicone) to

seal cap sheet

edge to scupper.

DETAIL NO :

DATE :

12-13-16

13STANDARD SCUPPER DETAIL

FLUID APPLIED RESTORATION COATING SYSTEM

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 13: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

ALSO SEE DETAIL 14b

FOR ISOMETRIC VIEW

1.

2.

STANDARD FLUID

APPLIED ROOF

SYSTEM

STORM COLLAR, IF

REQUIRED.

FINISH COAT OVER

ENTIRE ROOF.

BASE COAT, FABRIC,

AND BASE COAT

COMPONENTS.

6" min.

BASE COAT, 12” FABRIC, AND

BASE COAT COMPONENTS.

PLACE ADDITIONAL LAYERS

OF REINFORCING FABRIC AT

PENETRATION BASE, AS

SHOWN ON PLAN HERE AND

ON “ISOMETRIC VIEW” ON

DETAIL 14b.

BASE COAT, FABRIC,

AND BASE COAT

COMPONENTS.

ROOF DECK AND

INSULATION SYSTEM.

METAL OR PLASTIC VENT PIPE

PENETRATING ROOF MEMBRANE.

SECTION

plan

NOTES:

1. THIS DETAIL IS A TYPICAL

PENETRATION DETAIL

APPLICABLE FOR ALL COLD

PIPE PENETRATIONS. FOR

HOT PIPE PENETRATIONS

CONTACT THE MANUFACTURER

FOR REQUIREMENTS.

2. FOR PIPE PENETRATIONS

THAT EXCEED 18” ABOVE THE

ROOF SURFACE A STORM

COLLAR SHALL BE USED WITH

A DRAW BAND AND

CAULKING. THE ROOF

COATING SHALL

EXTEND 8” (MIN) UP

PENETRATION SURFACE.

3. FLUID APPLIED RESTORATION

COATING SYSTEM – BASE

COAT, REINFORCED FABRIC,

BASE COAT 2, AND FINISH

COAT COMPONENTS.

4. PRIMING – REFER TO

TROPICAL ROOFING

PRODUCTS SPECIFICATIONS

FOR DECK PRIMING

REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT

RECOMMENDATION REFER TO THE

APPROPRIATE FLUID APPLIED

SYSTEM GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

12"x12" reinf.

fabric over pipe

wrap

reinforcing

fabric pipe wrap

DETAIL NO :

DATE :

12-13-16

14aTYPICAL VENT PIPE FLASHING DETAIL

FLUID APPLIED RESTORATION COATING SYSTEM

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 14: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

REINFORCING

FABRIC PIPE WRAP

12” X 12” REINFORCING

FABRIC WITH PIPE

HOLE IN CENTER

pipe through

roof deck

1.2.

1.6"

hig

h

min

imum

REINFORCING

FABRIC PIPE WRAP

isometric view

2. LAYER

OF 12’ X 12” REINFORCING

FABRIC OVER PIPE WRAP

note: also see detail 14A

NOTES:

1. FLUID APPLIED RESTORATION

SYSTEM – BASE

COAT, REINFORCED FABRIC,

BASE COAT 2, AND FINISH COAT

COMPONENTS

2. PRIMING – REFER TO TROPICAL

ROOFING PRODUCTS

SPECIFICATIONS FOR DECK

PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT

RECOMMENDATION REFER TO THE

APPROPRIATE FLUID APPLIED

SYSTEM GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

DETAIL NO :

DATE :

12-13-16TYPICAL VENT PIPE FLASHING DETAIL

FLUID APPLIED RESTORATION COATING SYSTEM

14bdisclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 15: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

VENT / STACK PIPE

FLAT METAL PIPE

FLASHING

RUBBER CASING12” WIDE FABRIC

AND BASE COAT

(2 COATS) SPLICED

OVER FLAT METAL

FLASHING. COLOR

AS SPECIFIED.

VENT / STACK PIPE

RUBBER CASING

plan

SECTION

FLUID APPLIED RESTORATION

COATING SYSTEM – BASE

COAT, REINFORCED FABRIC,

BASE COAT 2, AND FINISH COAT

COMPONENTS.

FLAT METAL PIPE

FLASHING

NOTES:

1. ALL FLASHING SHALL BE DESIGNED

FOR THE APPLICABLE CONDITIONS.

METAL THICKNESS, FASTENERS, AND

LAPPING SHALL BE AS SPECIFIED BY

THE ROOF DESIGNER.

2. REFER TO THE SPECIFICATIONS FOR

SPECIFIC REQUIREMENTS.

3. FLUID APPLIED RESTORATION

COATING SYSTEM – BASE

COAT, REINFORCED FABRIC, BASE

COAT 2, AND FINISH COAT

COMPONENTS.

4. PRIMING – REFER TO TROPICAL

ROOFING PRODUCTS SPECIFICATIONS

FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT

RECOMMENDATION REFER TO THE

APPROPRIATE FLUID APPLIED SYSTEM

GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

16DETAIL NO :

DATE :

12-13-16VENT STACK PIPE DETAIL

FLUID APPLIED RESTORATION COATING SYSTEM

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 16: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

MECHANICAL EQUIPMENT

EQUIPMENT CURB AT

MIN. OF 8” ABOVE ROOF LINE

FINISH COAT COMPONENT OVER ENTIRE

ROOF. COLOR AS SPECIFIED.

FLUID APPLIED RESTORATION COATING

SYSTEM – BASE COAT, FLUID APPLIED

RESTORATION COATING SYSTEM – BASE

COAT, REINFORCED FABRIC, BASE COAT

2, AND FINISH COAT COMPONENTS.

12” BASE COAT FLUID APPLIED

RESTORATION COATING SYSTEM – BASE

COAT, REINFORCED FABRIC, BASE COAT

2, AND FINISH COAT COMPONENTS.

ROOF DECK

CONSTRUCTION

EQUIPMENT UNIT

MOUNTED ON ROOF

36"

TYPICAL

NOTES:

1. THIS DETAIL IS A TYPICAL FLASHING

DETAIL AT EQUIPMENT CURBS

2. PREPARE THE ROOF SURFACE AS

PER MANUFACTURERS

REQUIREMENTS PRIOR TO

APPLICATION OF ROOF COATING

3. REFER TO THE SPECIFICATIONS FOR

SPECIFIC REQUIREMENTS.

4. FLUID APPLIED RESTORATION

COATING SYSTEM – BASE

COAT, REINFORCED FABRIC, BASE

COAT 2, AND FINISH COAT

COMPONENTS.

5. PRIMING – REFER TO TROPICAL

ROOFING PRODUCTS

SPECIFICATIONS FOR DECK PRIMING

REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT

RECOMMENDATION REFER TO THE

APPROPRIATE FLUID APPLIED SYSTEM

GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

17DETAIL NO :

DATE :

12-13-16TYPICAL EQUIPMENT CURB FLASHING DETAIL

FLUID APPLIED RESTORATION COATING SYSTEM

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 17: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

FINISH COAT COMPONENT

OVER ENTIRE ROOF. COLOR

AS SPECIFIED.

BASE COAT, REINFORCED

FABRIC, AND BASE COAT

COMPONENTS.

4"

MIN

SHEET METAL FLASHING.

EPDM Flashing can also be used.

ROOF DECKING

INSULATION

ROOF E.J. CURB

NOTES:

1. PREPARE THE ROOF SURFACE AS PER MANUFACTURERS REQUIREMENTS

2. SHEET METAL FLASHING AND EXPANSION JOINT DESIGN PROFILE TO BE DETERMINED BY ROOF DESIGNER

3. FLUID APPLIED RESTORATION COATING SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH

COAT COMPONENTS.

4. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE

SPECIFICATIONS AT www.tropicalroofingproducts.com

DETAIL NO :

DATE :

12-13-16EXPANSION JOINT FLASHING DETAIL

FLUID APPLIED RESTORATION COATING SYSTEM

18disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 18: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

6"

MIN

6"

MIN

12” WIDE (MIN) BASE

COAT, REINFORCING FABRIC,

AND BASE COAT COMPONENTS

OVER EXISTING JOINT.

FLUID APPLIED RESTORATION

COATING SYSTEM – BASE

COAT, REINFORCED FABRIC,

BASE COAT 2, AND FINISH COAT

COMPONENTS.

ROOF DECK

INSULATION

NOTES:

1. FLUID APPLIED RESTORATION COATING SYSTEM – BASE COAT, REINFORCED FABRIC, BASE COAT 2, AND FINISH COAT

COMPONENTS

2. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE

SPECIFICATIONS AT www.tropicalroofingproducts.com

EXISTING EXPANSION JOINT

SHEET METAL OVER JOINT,

ADHERED AT ONE SIDE ONLY

19DETAIL NO :

DATE :

12-13-16ROOF EXPANSION JOINT DETAIL

FLUID APPLIED RESTORATION COATING SYSTEM

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 19: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

BASE COAT.

ridge cap

TROPICAL #950/951 MASTIC

FOR ACRYLIC. OR, Tropical

#9100 MASTIC FOR SILICONE

REINFORCED

FABRIC.

metal roof panel

BACKING

4" 4"

NOTES:

1. BACKING CAN BE POLYURETHANE FOAM.

2. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK

PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID

APPLIED SYSTEM GUIDE SPECIFICATIONS AT www.tropicalroofingproducts.com

FINISH COAT. COLOR AS SPECIFIED.

20DETAIL NO :

DATE :

RIDGE CAP DETAIL

FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 20: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

6" h

igh

minimum

sheet metal rib cap

fasteners

RIB CAPS INSTALLED OVER TROPICAL

#950/951 MASTIC FOR ACRYLIC OR,

TROPICAL #9100 MASTIC FOR SILICONE.

NOTES:

1. RIB CAPS ARE REQUIRED OVER

BROKEN RIBS; AFTER INSTALLED,

SEAL THE RIB CAP PERIMETER AND

FASTENERS WITH TROPICAL #950/951

MASTIC FOR ACRYLIC OR, TROPICAL

#9100 MASTIC FOR SILICONE.

2. PRIMING – REFER TO TROPICAL

ROOFING PRODUCTS SPECIFICATIONS

FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT

RECOMMENDATION REFER TO THE

APPROPRIATE FLUID APPLIED SYSTEM

GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

21DETAIL NO :

DATE :

RIB CAP DETAIL

FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 21: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

metal rake

metal wall panel

metal roof panel

NOTES:

1. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS

SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE

APPROPRIATE FLUID APPLIED SYSTEM GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

FINISH COAT. COLOR AS SPECIFIED.

BASE COAT.

TROPICAL #950/951 MASTIC FOR

ACRYLIC. OR, TROPICAL #9100

MASTIC FOR SILICONE.

6” OR 12” FABRIC FULLY EMBEDDED IN

TROPICAL #950/951 MASTIC FOR

ACRYLIC OR, TROPICAL #9100 MASTIC

FOR SILICONE.

22DETAIL NO :

DATE :

FLOATING RAKE

FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 22: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

8"

min

.

4"

min

. 2"

min

.

unlim

ited

heig

ht

NOTES:

1. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS

SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER

TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE

SPECIFICATIONS AT

www.tropicalroofingproducts.com

FINISH COAT

APPLY A BEAD OF TROPICAL #950/951

MASTIC FOR ACRYLIC. OR, TROPICAL

#9100 MASTIC FOR SILICONE, OR SEALANT

TROPICAL #950/951 MASTIC FOR ACRYLIC

OR, TROPICAL #9100 MASTIC FOR SILICONE.

6” OR 12” FABRIC FULLY EMBEDDED IN

TROPICAL #950/951 MASTIC FOR ACRYLIC OR,

TROPICAL #9100 MASTIC FOR SILICONE.

COUNTER FLASHING

STANDARD MOD-BIT, BUR, AND

SINGLE-PLY DETAIL

23DETAIL NO :

DATE :

WALL TERMINATION DETAIL

FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 23: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

2"M

IN2"

6"

NOTES:

1. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE

SPECIFICATIONS AT www.tropicalroofingproducts.com

FINISH COAT. COLOR

AS SPECIFIED.

BASE COAT.

TROPICAL #950/951 MASTIC

FOR ACRYLIC. OR, TROPICAL

#9100 MASTIC FOR SILICONE.

6” OR 12” FABRIC FULLY

EMBEDDED IN TROPICAL

#950/951 MASTIC FOR

ACRYLIC OR, TROPICAL

#9100 MASTIC FOR SILICONE.

METAL ROOF PANEL

BACKING

25DETAIL NO :

DATE :

CONCRETE WALL TRANSITION DETAIL

FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 24: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

2"2"

MIN6"

NOTES:

1. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE

SPECIFICATIONS AT www.tropicalroofingproducts.com

FINISH COAT. COLOR AS

SPECIFIED.

BASE COAT.

TROPICAL #950/951 MASTIC FOR

ACRYLIC. OR, TROPICAL #9100

MASTIC FOR SILICONE.

6” OR 12” FABRIC FULLY EMBEDDED

IN TROPICAL #950/951 MASTIC FOR

ACRYLIC OR, TROPICAL #9100

MASTIC FOR SILICONE.

METAL ROOF PANEL

BACKING

26DETAIL NO :

DATE :

METAL WALL TERMINATION DETAIL

FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 25: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

metal roof panel

6"

NOTES:

1. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE

SPECIFICATIONS AT www.tropicalroofingproducts.com

TROPICAL #950/951 MASTIC FOR

ACRYLIC. OR, TROPICAL #9100

MASTIC FOR SILICONE FOR

EXPOSED FASTENERS.

FINISH COAT. COLOR

AS SPECIFIED.

BASE COAT.

TROPICAL #950/951 MASTIC

FOR ACRYLIC. OR, TROPICAL

#9100 MASTIC FOR SILICONE.

SKYLIGHT PANEL. PLEASE

REFER TO THE SKYLIGHT

MANUFACTURER

INSTALLATION DETAILS.

6” FABRIC FULLY EMBEDDED IN

TROPICAL #950/951 MASTIC FOR

ACRYLIC OR, TROPICAL #9100

MASTIC FOR SILICONE AROUND

SKYLIGHT PERIMETER.

TROPICAL #950/951 MASTIC FOR ACRYLIC OR,

TROPICAL #9100 MASTIC FOR SILICONE

27DETAIL NO :

DATE :

FLUSH SKYLIGHT DETAIL

FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 26: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

metal roof panel

metal cricket

2"min

skylight

NOTES:

1. NEW CRICKETS SHALL BE SEALED BY PLACING A BEAD OF TROPICAL #950/951 MASTIC FOR ACRYLIC

OR, TROPICAL # 9100 MASTIC FOR SILICONE UNDER THE FLANGES BEFORE THEY ARE MECHANICALLY

ATTACHED

2. Vertical SEAMS TO BE CUT BACK A MINIMUM OF 2” FROM CRICKET

3. RIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM

GUIDE SPECIFICATIONS AT www.tropicalroofingproducts.com

TROPICAL #950/951

MASTIC FOR ACRYLIC.

OR, TROPICAL #9100

MASTIC FOR SILICONE

FINISH COAT. COLOR

AS SPECIFIED.

BASE COAT.

TROPICAL #950/951 MASTIC

FOR ACRYLIC. OR, TROPICAL

#9100 MASTIC FOR SILICONE

6” FABRIC FULLY EMBEDDED IN

TROPICAL #950/951 MASTIC FOR

ACRYLIC OR, TROPICAL #9100

MASTIC FOR SILICONE AROUND

SKYLIGHT PERIMETER.

28DETAIL NO :

DATE :

SKYLIGHT CURB DETAIL

FLUID APPLIED RESTORATION COATING SYSTEM 12-13-16

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 27: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

NOTES: vent pipes/ducts may

require crickets depending on

their size and location (crickets

not shown).

metal roof panel

4"

4"

NOTES:

1 PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED SYSTEM GUIDE

SPECIFICATIONS AT www.tropicalroofingproducts.com

FINISH COAT. COLOR AS SPECIFIED.

BASE COAT.

6” FABRIC FULLY EMBEDDED IN

TROPICAL #950/951 MASTIC FOR

ACRYLIC OR, TROPICAL #9100

MASTIC FOR SILICONE

TROPICAL #950/951 MASTIC FOR

ACRYLIC OR, TROPICAL #9100

MASTIC FOR SILICONE

29DETAIL NO :

DATE :

DUCT FLASHING DETAIL12-13-16FLUID APPLIED RESTORATION COATING SYSTEM

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

Page 28: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

NOTES:

1. ALL FLASHING SHALL BE DESIGNED FOR APPLICABLE CONDITIONS. METAL THICKNESS, FASTENERS,

AND LAPPING SHALL BE AS SPECIFIED BY THE ROOF DESIGNER.

2. REFER TO THE SPECIFICATIONS FOR SPECIFIC EXECUTION REQUIREMENTS

3. FLUID APPLIED RESTORATION COATING SYSTEM – BASE COAT, REINFORCED FABRIC, BASE

COAT 2, AND FINISH COAT COMPONENTS.

4. PRIMING – REFER TO TROPICAL ROOFING PRODUCTS SPECIFICATIONS FOR DECK PRIMING

REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT RECOMMENDATION REFER TO THE APPROPRIATE FLUID APPLIED

SYSTEM GUIDE SPECIFICATIONS AT www.tropicalroofingproducts.com

TAKE ENTIRE SYSTEM OVER TOP OF

PARAPET

TOP COAT COMPONENT OVER ENTIRE ROOF. COLOR AS

SPECIFIED.

FINISH COAT COMPONENT OVER ENTIRE ROOF. COLOR AS SPECIFIED

PARAPET WALL

TAKE 12” WIDE FINISH COAT, FABRIC, AND BASE COAT COMPONENTS

UP CANT AND TERMINATE VERTICALLY ON PARAPET

ROOF DECK AND INSULATION SYSTEM

WITH OR WITHOUT CANT STRIPS

OPTIONAL METAL COPING ASSEMBLY

FINISH COAT, FABRIC, AND FINISH COAT COMPONENTS

30DETAIL NO :

DATE :

WALL FLASHING DETAIL12-13-16

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

FLUID APPLIED RESTORATION COATING SYSTEM

Page 29: FINISH COAT COMPONENT OVER ENTIRE ... - Roof Coating …metal roof deck horizontal seam base coat, fabric (12") and base coat 2 NOTES: 1.PREPARE ALL ROOF SURFACES AS REQUIRED BY THE

6 "

min

.

1/4" MINUMUM SLOPE

6"

min

.

NOTES:

1. ALL FLASHING SHALL BE DESIGNED

FOR APPLICABLE CONDITIONS. METAL

THICKNESS, FASTENERS, AND LAPPING

SHALL BE AS SPECIFIED BY THE ROOF

DESIGNER.

2. REFER TO THE SPECIFICATIONS FOR

SPECIFIC EXECUTION REQUIREMENTS

3. FLUID APPLIED RESTORATION COATING

SYSTEM – BASE COAT, REINFORCED

FABRIC, BASE COAT 2, AND FINISH

COAT COMPONENTS.

4. PRIMING – REFER TO TROPICAL

ROOFING PRODUCTS SPECIFICATIONS

FOR DECK PRIMING REQUIREMENTS.

NOTE: FOR SPECIFIC PRODUCT

RECOMMENDATION REFER TO THE

APPROPRIATE FLUID APPLIED SYSTEM

GUIDE SPECIFICATIONS AT

www.tropicalroofingproducts.com

section

elevation

WALL OF FLUTED CMU

TAKE BASE COAT, 12” WIDE FABRIC, AND

BASE COAT COMPONENTS AND

TERMINATE 6” MIN. VERTICALLY ON WALL.

FLUID APPLIED RESTORATION COATING

SYSTEM – BASE COAT, REINFORCED

FABRIC, BASE COAT 2, AND FINISH COAT.

WALL OF FLUTED CMU

TAKE BASE

COAT, REINFORCING

FABRIC, AND BASE COAT

COMPONENTS AND

TERMINATE 6” MINIMUM

VERTICALLY ON WALL.

SLOPED

METAL ROOF

31DETAIL NO :

DATE :

ROOF TO WALL DETAIL12-13-16

disclaimer : Tropical Roofing Products manufactures Acrylic, SEBS, and Silicone Fluid Applied Restoration Systems. Some Silicone Systems do not require primer. Always check the Tropical Roofing Products system guide specifications for complete application details.

FLUID APPLIED RESTORATION COATING SYSTEM