Fibre Small Form Pluggable Transceivers with Built-in ... · • Integral Micro-OTDR SFP...

10
Certified iSFPs/SFP+ Fibre Small Form Pluggable Transceivers with Built-in Micro OTDR

Transcript of Fibre Small Form Pluggable Transceivers with Built-in ... · • Integral Micro-OTDR SFP...

Page 1: Fibre Small Form Pluggable Transceivers with Built-in ... · • Integral Micro-OTDR SFP Transceiver • Dual Fibre, Full Duplex, SFP • Dead Zone of 30 metres or Less • Resolution

Certified iSFPs/SFP+

Fibre Small Form Pluggable Transceivers with Built-in Micro OTDR

Page 2: Fibre Small Form Pluggable Transceivers with Built-in ... · • Integral Micro-OTDR SFP Transceiver • Dual Fibre, Full Duplex, SFP • Dead Zone of 30 metres or Less • Resolution

www.net2edge.com | Tel: +44 (O) 345 O13OO3O2

• Integral Micro-OTDR SFP Transceiver

• Dual Fibre, Full Duplex, SFP

• Dead Zone of 30 metres or Less

• Resolution of 10 metres or Better

• Accuracy of 50 metres or Better

• Minimum 34 dB Link Budget for FE Data Model

• Minimum 26dB Link Budget for GbE Data Model

• Minimum 65dB Dynamic Range for the TxOTDR™

• Automatically Transitions to Micro-OTDR Mode

• Operates Anywhere Conventional SFPs

• Low power dissipation <1.5W

• Available operating temperature range: -20°C to 85°C

Net2Edge provides advanced optical solutions through Intelligent Optical Transceivers (iSFP/iSFP+). The portfolio includes an iSFP with integrated Micro-OTDR (uOTDR™) that automatically Detects, Locates and Reports Optical Fibre Faults.

Designed in conformance with the Small Form Factor Pluggable 20-pin Multi-Source Agreement (MSA) is available to facilitate integration within existing equipment and management systems. It comes with

SNMP management interface that allows configuration and helps to monitor relevant parameters.

iSFP-uOTDR Series SFP Transceivers transmit and receive full duplex data over conventional two-fibre optical communication links. Upon disruption of the data link, or failure to connect, the Transmitter Section of the SFP unit switches into TxOTDR™ Mode, emitting optical power pulses (> +13 dBm) and detecting the reflected pulses at least down to -52 dBm optical power.

Overview

Data Sheet

Providing advanced optical solutions

through Intelligent Optical Transceivers

(iSFP/iSFP+)

IDFC™ Series

Product Features

Description

Dual Fibre, full duplex SFP with Built-in Micro-OTDR

Page 3: Fibre Small Form Pluggable Transceivers with Built-in ... · • Integral Micro-OTDR SFP Transceiver • Dual Fibre, Full Duplex, SFP • Dead Zone of 30 metres or Less • Resolution

www.net2edge.com | Tel: +44 (O) 345 O13OO3O3

Data Sheet

iSPF-OTDR

The integration of a Micro-OTDR into an SFP greatly reduces Network Mean-Time-To-Repair (MTTR) by Identifying the Cable Fault location without having to send a technician with a field OTDR, and brings CAPEX and OPEX savings. Other major benefits are:

• Physical Layer Fault Detection

• Distributed Remote Fibre Monitoring

• No Additional Special Equipment

• Eliminates Fault Detection Delay

Fibre faults and intermittent connections present optical reflections of varying intensities. The reflection intensity of a fibre break has a known statistical distribution.

Monitoring multiple fibres in the same trunk increases the detection probability (each fibre breaks differently). A fibre link may be monitored from one side, or both

Automatically Detects, Locates and Reports Optical Fibre Faults.

Fibre Fault Detection from one end - randomly distributed fault Fibre Fault Detection from at least one end

Value Proposition

Page 4: Fibre Small Form Pluggable Transceivers with Built-in ... · • Integral Micro-OTDR SFP Transceiver • Dual Fibre, Full Duplex, SFP • Dead Zone of 30 metres or Less • Resolution

www.net2edge.com | Tel: +44 (O) 345 O13OO3O4

Data Sheet

iSPF-OTDR

Parameter Symbol Min Typical Max Unit

Absolute Supply Voltage Vcc_max 0 - 3.6 V

Operating Case Temperature Top -20 - +70 °C

Operating Relative Humidity RHop 5 - +95 %

Storage and Transportation Temperature Tst -40 - +85 °C

Parameter Symbol Min Typ Max Min Typ Max Unit

Average Optical Output Power – FastE Po -2 0 1 -2 0 1 dBm

Output Eye Conformance IEEE 802.3-2008 SONET OC-3 SDH STM-1

IEEE 802.3-2008

Receiver (Ethernet Sensitivity/Overload referenced to BER < 10E-12 with 2^7-1 PRBS; SONET/SDH Sensitivity and Overload referenced to BER < 10E-10 with 2^23-1 PRBS.)

Parameter at Specified Bit Rate (Mbps) Symbol 125 - 156 125 - 1250 Unit

Average Output Power 34 - 34 19 - 26 dBm

Average Output Power 32 - 32 17 - 24 dBm

Parameter Symbol Min Typ Max Min Typ Max Unit

Average Optical Input Power – FastE PMin - - -36 - - -28 dBm

Loss Of Signal De-Asserted – FastE PD - -37 - - -29 - dBm

Loss Of Signal Asserted – FastE PA - -38 - - -30 - dBm

Output Eye Conformance IEEE 802.3-2008 SONET OC-3 SDH STM-1

IEEE 802.3-2008

Link

Reach Category: Ultra-Long Reach1OO Km Class

Ultra-Long Reach8O Km Class

Model Series: S-Series(FastE / OC-3 / STM-1)

C-Series(FastE / GbE)

Part Nomenclature: Duplex LC/UPCReceptacle:

EN-iSFPFE-AF1OOCxx EN-iSFP1G-AFXOCxx

Transmitter

Recommended Operating Conditions

Optical Characteristics

(-2OºC to +7OºC)

Page 5: Fibre Small Form Pluggable Transceivers with Built-in ... · • Integral Micro-OTDR SFP Transceiver • Dual Fibre, Full Duplex, SFP • Dead Zone of 30 metres or Less • Resolution

www.net2edge.com | Tel: +44 (O) 345 O13OO3O5

Data Sheet

iSPF-OTDR

Standards & Compliance

Ordering Information

Compatibility; Tested and Proven

• Proven Compatibility and Interoperability with; Cisco, Juniper, ALCATEL-LUCENT, ADVA, Brocade, CIENA, Huawei, PacketLight, Transmode, NEtInsight, ToyoTech, etc.

Regulatory Compliance

• Test and Visibility equipment such as; IXIA, GIGAMON, VSS, SPIRENT, JDSU, XENA, EXFO, etc. Regulatory Compliance

• The Smart iSFP complies with international Electromagnetic Compatibility (EMC) and international safety requirements and standards.

• EMC performance is dependent on the overall system design.

• The Smart iSFP is lead-free and RoHS2-compliant per Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment.

Part Number Description Data Rate Connector Distance (km)

iSFP-uOTDR 1GbE/CWDM (xx=ITU Ch# 1271-1611nm)

EN-iSFP1G-AO4OCxx OTDR Reflector 1000BASE-EX SFP, 40kmover SMF iDFC GbE 1xx1 nm DFB 20dB DRDuplex LC/UPC Receptacle

1.25G LC 40

EN-iSFP1G-AF4OCxx uOTDR 1000BASE-EX SFP, 40km over SMF,iDFC GbE 1xx1nm DFB 20 dB uOTDR 65dBDR Duplex LC/UPC Receptacle

1.25G LC 40

EN-iSFP1G-AO8OCxx OTDR Reflector 1000BASE-ZX SFP, 80kmover SMF iDFC GbE 1xx1nm DFB 26dB DRDuplex LC/UPC Receptacle

1.25G LC 80

EN-iSFP1G-AF8OCxx uOTDR 1000BASE-ZX SFP, 80km over SMF,iDFC GbE 1xx1nm DFB 26dB uOTDR 65dBDR Duplex LC/UPC Receptacle

1.25G LC 80

iSFP-uOTDR FE Fast Ethernet (xx= ITU CH #1271-1611nm)

EN-iSFPFE-AO1OOCxx OTDR Reflector FastE SFP, 100km over SMFiDFC FE 1xx1nm DFB 34dB DR Duplex LC/UPC Receptacle

FastE/OC-3/STM-1

LC 100

EN-iSFPFE-AF1OOCxx uOTDR FastE SFP, 100km over SMF, iDFC FE1xx1nm DFB 34dB uOTDR 65dB DR DuplexLC/UPC Receptacle

FastE/OC-3/STM-1

LC 100

Page 6: Fibre Small Form Pluggable Transceivers with Built-in ... · • Integral Micro-OTDR SFP Transceiver • Dual Fibre, Full Duplex, SFP • Dead Zone of 30 metres or Less • Resolution

www.net2edge.com | Tel: +44 (O) 345 O13OO3O6

Data Sheet

iSPF-OTDR

• Integral Micro-OTDR SFP Transceiver

• Single Fiber, Full Duplex, SFP

• SC or LC connector available

• Dead Zone of 30 metres or Less

• Resolution of 10 metres or Better

• Accuracy of 50 metres or Better

• Minimum 20 dB Optical Link Budget

• 55 dB Dynamic Range for the uOTDR

• Reflection Immune Operation – Any Network Type

• Automatically Transitions to Micro-OTDR Mode

• Low power dissipation <1.5W

• Available operating temperature range: -20°C to 70°C

Net2Edge provides advanced optical solutions through Intelligent Optical Transceivers (iSFP/iSFP+). The portfolio includes an iSFP with integrated Micro-OTDR (uOTDR™) that automatically Detects, Locates and Reports Optical Fiber Faults.

Designed in conformance with the Small Form Factor Pluggable 20-pin Multi-Source Agreement (MSA) is available to facilitate integration within existing equipment and management systems.

It comes with SNMP management interface that allows configuration and helps to monitor relevant parameters. iSFP-uOTDR Series SFP Transceivers transmit and receive at the same wavelength, doubling the optical fiber plant capacity. Upon disruption of data link, or failure to connect, the unit switches into uOTDR Mode, emitting optical power pulses (>+13 dBm) and detecting the reflected pulses at least down to -42 dBm optical power.

Reflection Immune Operation resolves self-reflection from an open connector and/or other reflectors. Only remote data is transferred into the host equipment.

Overview

Reflection Immune Operation resolves

self-reflection from an open connector and/

or other reflectors.

Product Features

Description

Single Fibre SFP with Built-in Micro-OTDR

Data Sheet

IDFC™ Series

Page 7: Fibre Small Form Pluggable Transceivers with Built-in ... · • Integral Micro-OTDR SFP Transceiver • Dual Fibre, Full Duplex, SFP • Dead Zone of 30 metres or Less • Resolution

www.net2edge.com | Tel: +44 (O) 345 O13OO3O7

Data Sheet

iSPF-OTDR

The integration of a Micro-OTDR into an SFP greatly reduces Network Mean-Time-To-Repair (MTTR) by Identifying the Cable Fault location without having to send a technician with a field OTDR, and brings CAPEX and OPEX savings. Other major benefits are:

• Physical Layer Fault Detection

• Distributed Remote Fibre Monitoring

• No Additional Special Equipment

• Eliminates Fault Detection Delay

Automatically Detects, Locates and Reports Optical Fibre Faults

Fibre faults and intermittent connections present optical reflections of varying intensities. The reflection intensity of a fibre break has a known statistical distribution. Monitoring multiple fibres in the same trunk increases the detection probability (each fibre breaks differently). A fibre link may be monitored from one side, or both sides, for example, when ring topology is utilized.

Fibre Fault Detection from at least one end

Value Proposition

Page 8: Fibre Small Form Pluggable Transceivers with Built-in ... · • Integral Micro-OTDR SFP Transceiver • Dual Fibre, Full Duplex, SFP • Dead Zone of 30 metres or Less • Resolution

www.net2edge.com | Tel: +44 (O) 345 O13OO3O8

Data Sheet

iSPF-OTDR

Parameter Symbol Min Typical Max Unit

Absolute Supply Voltage Vcc_max 0 - 3.6 V

Operating Case Temperature Top -20 - +70 °C

Operating Relative Humidity RHop 5 - +95 %

Storage and Transportation Temperature Tst -40 - +85 °C

Parameter Symbol Min Typ Max Unit

Average Optical Output Power – FastE/GbE Po -2 0 1 dBm

Output Eye Conformance IEEE 802.3-2008

Receiver GbE Sensitivity/Overload referenced to BER < 10E-12 with 2^7-1 PRBS)

Parameter Symbol Min Typ Max Unit

Average Optical Input Power – FastE Pmin - -23 -22 dBm

Loss Of Signal De-Asserted – FastE PD - -23 - dBm

Loss Of Signal Asserted – FastE PA - -25 - dBm

Output Eye Conformance IEEE 802.3-2008

Link (*Note: FastE Sensitivity penalty is 7dB)

Parameter at Specified Bit Rate (Mbps) Symbol 125 - 1250 Unit

Minimum Data Sheet Optical Power Budget 13 - 20 dBm

Minimum Planning Optical Power Budget 11 - 18 dBm

Minimum Required Optical Return Loss ORL 24 - 24 dBm

Reach Category: Category: Medium Reach 4O km Class

Model Series: C-Series (FastE / GbE)

Part Nomenclature: Duplex LC/UPC Receptacle: EN-iSFPBX-AFXOCxx

Transmitter

Recommended Operating Conditions

Optical Characteristics

(-2OºC to +7OºC)

Page 9: Fibre Small Form Pluggable Transceivers with Built-in ... · • Integral Micro-OTDR SFP Transceiver • Dual Fibre, Full Duplex, SFP • Dead Zone of 30 metres or Less • Resolution

www.net2edge.com | Tel: +44 (O) 345 O13OO3O9

Data Sheet

iSPF-OTDR

Standards & Compliance

Ordering Information

Compatibility; Tested and Proven

• Proven Compatibility and Interoperability with; Cisco, Juniper, ALCATEL-LUCENT, ADVA, Brocade, CIENA, Huawei, PacketLight, Transmode, NEtInsight, ToyoTech, etc.

• Test and Visibility equipment such as; IXIA, GIGAMON, VSS, SPIRENT, JDSU, XENA, EXFO, etc.

Regulatory Compliance

• The Smart iSFP complies with international Electromagnetic Compatibility (EMC) and international safety requirements and standards.

• EMC performance is dependent on the overall system design.

• The Smart iSFP is lead-free and RoHS2-compliant per Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment.

Part Number Description Data Rate Connector Distance (km)

iSFP-uOTDR 1GbE/CWDM (xx=ITU Ch# 1311, 1451, 1471, 1491, 1511, 1531, 1551, 1571, 1591, 1611nm)

EN-iSFPBX-AO4OCxx OTDR REFLECTOR 1000BASEEX SFP, 40kmover SMF iSFC GbE 1xx1 nm DFB 20 dB DRSingle Fibre LC/UPC Receptacle

1.25G LC 40

EN-iSFPBX-AF4OCxx uOTDR 1000BASE-EX SFP, 40km over SMF,iSFC GbE 1xx1 nm DFB 20 dB uOTDR 55 dBDR Single Fibre LC/UPC Receptacle

1.25G LC 40

iSFP-uOTDR FE Fast Ethernet (xx= ITU CH #1311, 1451, 1471, 1491, 1511, 1531, 1551, 1571, 1591, 1611nm)

EN-iSFPBX-AO8OCxx OTDR REFLECTOR FastE SFP, 100km overSMF iSFC FE 1xx1 nm DFB 34 dB DR SingleFibre LC/UPC Receptacle

FastE LC 80

EN-iSFPBX-AF8OCxx uOTDR FastE SFP, 100km over SMF, iSFC FE1xx1 nm DFB 34 dB uOTDR 65 dB DR singlefibre LC/UPC Receptacle

FastE LC 80

Page 10: Fibre Small Form Pluggable Transceivers with Built-in ... · • Integral Micro-OTDR SFP Transceiver • Dual Fibre, Full Duplex, SFP • Dead Zone of 30 metres or Less • Resolution

[email protected]+44 (0) 345 0130 030

Net2Edge Limited, Kulite House, Stroudley RoadBasingstoke Hampshire RG24 8UG United Kingdom

2019 v10