FDD Parameter Audit - 20131201

48
Network Operations Eastern Region Network Optimization Date : 1 ST Dec, 2013 FDD Parameter Audit STC MS Project – Eastern Region

description

FDD parameter Audit

Transcript of FDD Parameter Audit - 20131201

Page 1: FDD Parameter Audit - 20131201

Network OperationsEastern Region Network Optimization

Date : 1ST Dec, 2013

FDD Parameter AuditSTC MS Project – Eastern Region

Page 2: FDD Parameter Audit - 20131201

SUMMARY

1. Drop Call2. Access3. Paging4. Intra-RAT5. Inter-RAT6. Service Throughput7. Common Parameter

Page 3: FDD Parameter Audit - 20131201

1.Drop Call

1. T3102. T3113. N3114. N3105. S1MessageWaitingTimer6. X2MessageWaitingTimer7. UeInactiveTimer

Page 4: FDD Parameter Audit - 20131201

1.1 Drop Call - T310

Version Parameter Value No Of Cells

Eran 3.0 MS1000_T310 822Eran 2.1 MS200_T310 6Eran 2.1 MS1000_T310 510

Value Range: MS0_T310(0ms), MS50_T310(50ms), MS100_T310(100ms), MS200_T310(200ms), MS500_T310(500ms), MS1000_T310(1000ms), MS2000_T310(2000ms)

Default Value = MS1000_T310 (1000ms) Eran 3.0Default Value = MS200_T310 (200ms) Eran 2.1

Meaning: Indicates the length of timer 310. For details, see 3GPP TS 36.331.

Page 5: FDD Parameter Audit - 20131201

1.2 Drop Call - T311

Version Parameter Value No Of Cells

Eran 3.0 MS10000_T311 822Eran 2.1 MS10000_T311 516

Value Range: MS1000_T311(1000ms), MS3000_T311(3000ms), MS5000_T311(5000ms), MS10000_T311(10000ms), MS15000_T311(15000ms), MS20000_T311(20000ms), MS30000_T311(30000ms)

Default Value = MS10000_T311 (10000ms)

Meaning: Indicates the length of timer 311. For details, see 3GPP TS 36.331.

Page 6: FDD Parameter Audit - 20131201

1.3 Drop Call – N311

Version Parameter Value No Of Cells

Eran 3.0 n1 822Eran 2.1 n1 510Eran 2.1 n5 6

Value Range: n1(1), n2(2), n3(3), n4(4), n5(5), n6(6), n8(8), n10(10)

Default Value = n1 Eran 3.0Default Value = n5 Eran 2.1

Meaning: Indicates the length of timer 311. For details, see 3GPP TS 36.331.

Page 7: FDD Parameter Audit - 20131201

1.4 Drop Call – N310

Version Parameter Value No Of Cells

Eran 3.0 n10 822Eran 2.1 n6 6Eran 2.1 n10 510

Value Range: n1(1), n2(2), n3(3), n4(4), n6(6), n8(8), n10(10), n20(20)

Default Value = n10 Eran 3.0Default Value = n6 Eran 2.1

Meaning: Indicates the maximum number of successive "out of sync" indications received from L1.

Page 8: FDD Parameter Audit - 20131201

1.5 Drop Call – S1MessageWaitingTimer

Version Parameter Value No Of eNodeBs

Eran 3.0 20 274

Eran 2.1 Eran 2.1 do not have this para

Value Range: 10~200

Default Value = 20

Meaning: Indicates the timer governing the period the eNodeB will wait for a response message from the MME.

Page 9: FDD Parameter Audit - 20131201

1.6 Drop Call – X2MessageWaitingTimer

Version Parameter Value No Of eNodeBs

Eran 3.0 20 274

Eran 2.1 Eran 2.1 do not have this para

Value Range: 10~200

Default Value = 20

Meaning: Indicates the timer governing the period the eNodeB will wait for a response message from the MME.

Page 10: FDD Parameter Audit - 20131201

1.7 Drop Call – UeInactiveTimer

Version Parameter Value No Of eNodeBs

Eran 3.0 20 274Eran 2.1 1800 1Eran 2.1 10 171

Value Range: 0~3600

Default Value = 20 Eran 3.0Default Value = 1800 Eran 2.1

Meaning: Indicates the length of the UE inactivity timer. The eNodeB monitors whether UEs are receiving or sending data. When a UE has neither received nor sent data for a duration exceeding this period of time, the eNodeB releases the radio resources for the UE. If this parameter is set to 0, the UE inactivity timer is not used.

Page 11: FDD Parameter Audit - 20131201

2.Access

1. T3002. CellRadius3. CellBarred4. InitPdcchSymNum5. UuMsgSimulSendSwitch

Page 12: FDD Parameter Audit - 20131201

2.1 Access – T300

Version Parameter Value No Of Cells

Eran 3.0 MS200_T300 822Eran 2.1 MS200_T300 516

Value Range: MS100_T300(100ms), MS200_T300(200ms), MS300_T300(300ms), MS400_T300(400ms), MS600_T300(600ms), MS1000_T300(1000ms), MS1500_T300(1500ms), MS2000_T300(2000ms)

Default Value = MS200_T300

Meaning: Indicates the timer value of Timer 300. For details, see 3GPP TS 36.331.

Page 13: FDD Parameter Audit - 20131201

2.2 Access – CellBarred

Version Parameter Value No Of Cells

Eran 3.0 CELL_NOT_BARRED 822Eran 2.1 CELL_NOT_BARRED 516

Value Range: CELL_BARRED(Barred), CELL_NOT_BARRED(Not Barred)

Default Value = CELL_NOT_BARRED

Meaning: Indicates the radius of the cell.

Page 14: FDD Parameter Audit - 20131201

2.3 Access – CellRadius

Version Parameter Value No Of Cells

Eran 3.0 4000 567Eran 3.0 10000 255Eran 2.1 4000 414Eran 2.1 10000 102

Value Range: 1~100000

Default Value = 10000 (m)

Meaning: Indicates the radius of the cell.

We opt this parameter for good access, some site changed to 10000 meters.

Page 15: FDD Parameter Audit - 20131201

2.4 Access – InitPdcchSymNum

Version Parameter Value No Of Cells

Eran 3.0 1 798Eran 3.0 3 24Eran 2.1 3 516

Value Range: 1~4

Default Value = 3

Meaning: Indicates the number of OFDM symbols initially occupied by the PDCCH.

Page 16: FDD Parameter Audit - 20131201

2.5 Access – UuMsgSimulSendSwitch

Version Parameter Value No Of eNodeBs

Eran 3.0 OFF 120Eran 3.0 ON 154

Eran 2.1 Eran 2.1 do not have this para

Value Range: OFF(Off), ON(On)

Default Value = ON

Meaning: Indicates whether an eNodeB uses serial or parallel message transmission mode during security mode activation and RRC reconfiguration procedures. If this parameter is set to ON, the eNodeB uses parallel transmission mode. If this parameter is set to OFF, the eNodeB uses serial transmission mode.

Page 17: FDD Parameter Audit - 20131201

3.Paging

1. ModifyPeriodCoeff2. PchPwr3. DefaultPagingCycle4. Nb

Page 18: FDD Parameter Audit - 20131201

3.1 Paging – ModifyPeriodCoeff

Version Parameter Value No Of Cells

Eran 3.0 MOD_PERIOD_COEFF_N2 816Eran 3.0 MOD_PERIOD_COEFF_N4 6Eran 2.1 MOD_PERIOD_COEFF_N4 516

Value Range: MOD_PERIOD_COEFF_N2(2), MOD_PERIOD_COEFF_N4(4), MOD_PERIOD_COEFF_N8(8), MOD_PERIOD_COEFF_N16(16)

Default Value = MOD_PERIOD_COEFF_N2 Eran 3.0Default Value = MOD_PERIOD_COEFF_N4 Eran 2.1

Meaning: Indicates the modification period coefficient for the BCCH. BCCH modification period = Modification period coefficient x Default paging cycle, where the BCCH modification period and default paging cycle are measured in unit of radio frames, and the modification period coefficient is specified by this parameter.

Page 19: FDD Parameter Audit - 20131201

3.2 Paging – PchPwr

Version Parameter Value No Of Cells

Eran 3.0 0 822Eran 2.1 0 516

Value Range: -3175~3175

Default Value = 0

Meaning: Indicates the offset of the transmit power for the paging information on the PDSCH channel relative to the reference signal power.

Page 20: FDD Parameter Audit - 20131201

3.3 Paging – DefaultPagingCycle

Version Parameter Value No Of Cells

Eran 3.0 rf128 822Eran 2.1 rf128 516

Value Range: rf32(32 radio frames), rf64(64 radio frames), rf128(128 radio frames), rf256(256 radio frames)

Default Value = rf128

Meaning: Indicates the default paging period for the cell. It is also called the discontinuous reception (DRX) period. If the EPC specifies a DRX period for a UE, the UE compares this period with the value of this parameter and uses the smaller one as its DRX period. If the EPC does not specify a DRX period, the UE uses the value of this parameter, which is delivered in the system information, as its DRX period. For details, see 3GPP TS 36.304.

Page 21: FDD Parameter Audit - 20131201

3.4 Paging – Nb

Version Parameter Value No Of Cells

Eran 3.0 ONET 822Eran 2.1 ONET 516

Value Range: FOURT, TWOT, ONET, HALFT, QUARTERT, ONE_EIGHTT, ONE_SIXTEENTHT, ONE_THIRTY_SECONDT

Default Value = ONET

Meaning: Indicates the number of paging occasions (subframes or times of paging) contained in a paging cycle.For details, see 3GPP TS 36.304.

Page 22: FDD Parameter Audit - 20131201

4.Intra-RAT

1. IntraFreqHoA3Hyst2. IntraFreqHoA3Offset3. IntraFreqHoA3TimeToTrig

Page 23: FDD Parameter Audit - 20131201

4.1 Intra-RAT – IntraFreqHoA3Hyst

Version Parameter Value No Of Cells

Eran 3.0 4 822Eran 2.1 4 516

Value Range: 0~30

Default Value = 2 (0.5dB)

Meaning: Indicates the hysteresis for event A3 associated with intra-frequency handover. This parameter prevents frequent triggering of event evaluation due to radio signal fluctuations. This reduces the probability of ping-pong handovers or handover decision errors. A larger value of this parameter results in a lower probability. The hysteresis for event A3 associated with inter-frequency handover is the same as the value of this parameter. For details, see 3GPP TS 36.331.

HQ evaluate this parameter for STC NW, give the suggestion to change to 4.

Page 24: FDD Parameter Audit - 20131201

4.2 Intra-RAT – IntraFreqHoA3Offset

Version Parameter Value No Of Cells

Eran 3.0 4 822Eran 2.1 4 516

Value Range: 0~30

Default Value = 2 (0.5dB)

Meaning: Indicates the offset for event A3. If the parameter is set to a large value, an intra-frequency handover is performed only when the signal quality of the neighboring cell is significantly better than that of the serving cell and other triggering conditions are met. For details, see 3GPP TS 36.331.

HQ evaluate this parameter for STC NW, give the suggestion to change to 4.

Page 25: FDD Parameter Audit - 20131201

4.3 Intra-RAT – IntraFreqHoA3TimeToTrig

Version Parameter Value No Of Cells

Eran 3.0 320ms 822Eran 2.1 320ms 516

Value Range: 0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

Default Value = 320ms

Meaning: Indicates the offset for event A3. If the parameter is set to a large value, an intra-frequency handover is performed only when the signal quality of the neighboring cell is significantly better than that of the serving cell and other triggering conditions are met. For details, see 3GPP TS 36.331.

Page 26: FDD Parameter Audit - 20131201

5.Inter-RAT

1. SNonIntraSearch2. ThrshServLow3. InterRatHoA1A2Hyst4. InterRatHoA1A2TimeToTrig5. InterRatHoA1ThdRsrp6. InterRatHoA1ThdRsrq7. InterRatHoA2ThdRsrp8. InterRatHoA2ThdRsrq9. BlindHoA2ThdOffset10. InterRatHoUtranB1ThdRscp 11. CsfbHoUtranB1ThdRscp12. InterRatHoA1A2TrigQuan

Page 27: FDD Parameter Audit - 20131201

5.1 Inter-RAT – SNonIntraSearch

Version Parameter Value No Of Cells

Eran 3.0 7 822Eran 2.1 7 513Eran 2.1 10 3

Value Range: 0~31

Default Value = 7 (2dB)

Meaning: Indicates the measurement triggering threshold for reselection to inter-frequency or inter-RAT cells. The step is 2 dB.

HQ recommended to set as 7.

Page 28: FDD Parameter Audit - 20131201

5.2 Inter-RAT – ThrshServLow

Version Parameter Value No Of Cells

Eran 3.0 7 822Eran 2.1 7 513Eran 2.1 10 3

Value Range: 0~31

Default Value = 7 (2dB)

Meaning: Indicates the threshold used in the evaluation of reselection to a cell on a lower priority E-UTRAN frequency or on an inter-RAT frequency. Cell reselection to a cell on a lower priority E-UTRAN frequency or on an inter-RAT frequency is performed if no cell on the serving frequency or on a higher priority E-UTRAN frequency fulfills criteria 1 for inter-frequency and inter-RAT reselections. For details, see 3GPP TS 36.304.

HQ recommended to set as 7.

Page 29: FDD Parameter Audit - 20131201

5.3 Inter-RAT – InterRatHoA1A2Hyst

Version Parameter Value No Of Cells

Eran 3.0 2 798Eran 3.0 4 24Eran 2.1 2 3Eran 2.1 4 513

Value Range: 0~30

Default Value = 2 (0.5dB) Eran 3.0Default Value = 4 (0.5dB) Eran 2.1

Meaning: Indicates the hysteresis for inter-RAT measurement events A1 and A2. This parameter is used to prevent frequent triggering of event evaluation caused by radio signal fluctuation. In this way, the probability of ping-pong handovers or handover decision errors is reduced. A larger value of this parameter results in a lower probability.

Page 30: FDD Parameter Audit - 20131201

5.4 Inter-RAT – InterRatHoA1A2TimeToTrig

Version Parameter Value No Of Cells

Eran 3.0 640ms 822Eran 2.1 640ms 516

Value Range: 0ms, 40ms, 64ms, 80ms, 100ms, 128ms, 160ms, 256ms, 320ms, 480ms, 512ms, 640ms, 1024ms, 1280ms, 2560ms, 5120ms

Default Value = 640ms

Meaning: Indicates the time-to-trigger for inter-RAT measurement event A1 or A2.When detecting that the signal quality in the serving cell meets the entering condition, the UE does not send a measurement report to the eNodeB immediately. Instead, the UE sends a report only when the signal quality continuously meets the entering condition during the time-to-trigger.

Page 31: FDD Parameter Audit - 20131201

5.5 Inter-RAT – InterRatHoA1ThdRsrp

Version Parameter Value No Of Cells

Eran 3.0 -111 822Eran 2.1 -111 513Eran 2.1 -105 3

Value Range: -141~-43

Default Value = -111 (dBm)

Meaning: Indicates the RSRP threshold for inter-RAT measurement event A1.When the measured RSRP value of the serving cell exceeds this threshold, an event A1 report will be sent. The value -141 does not take effect and is reserved for backward compatibility. If this parameter is set to -141, the value -140 is used as the threshold in implementation.

HQ recommended to set as -111.

Page 32: FDD Parameter Audit - 20131201

5.6 Inter-RAT – InterRatHoA1ThdRsrq

Version Parameter Value No Of Cells

Eran 3.0 -20 822Eran 2.1 -20 516

Value Range: -40~-6

Default Value = -20 (0.5dB)

Meaning: Indicates the RSRQ threshold for inter-RAT measurement event A1.When the measured RSRQ value of the serving cell exceeds this threshold, an event A1 report will be sent.

Page 33: FDD Parameter Audit - 20131201

5.7 Inter-RAT – InterRatHoA2ThdRsrp

Version Parameter Value No Of Cells

Eran 3.0 -115 822Eran 2.1 -115 513Eran 2.1 -109 3

Value Range: -141~-43

Default Value = -115 (dBm)

Meaning: Indicates the RSRP threshold for inter-RAT measurement event A2.When the measured RSRP value of the serving cell is below this threshold, an event A2 report will be sent. The value -141 does not take effect and is reserved for backward compatibility. If this parameter is set to -141, the value -140 is used as the threshold in implementation.

HQ recommended to set as -115.

Page 34: FDD Parameter Audit - 20131201

5.8 Inter-RAT – InterRatHoA2ThdRsrq

Version Parameter Value No Of Cells

Eran 3.0 -24 822Eran 2.1 -24 516

Value Range: -40~-6

Default Value = -24 (0.5dB)

Meaning: Indicates the RSRQ threshold for inter-RAT measurement event A2.When the measured RSRQ value of the serving cell is below this threshold, an event A2 report will be sent.

Page 35: FDD Parameter Audit - 20131201

5.9 Inter-RAT – BlindHoA2ThdOffset

Version Parameter Value No Of Cells

Eran 3.0 6 822

Eran 2.1 Eran 2.1 do not have this para

Value Range: 0~15

Default Value = 6 (dB) Eran 3.0

Meaning: Indicates the offset of the A2 threshold for inter-RAT blind redirection against the A2 threshold for inter-RAT handovers.

Page 36: FDD Parameter Audit - 20131201

5.10 Inter-RAT – InterRatHoUtranB1ThdRscp

Version Parameter Value No Of Cells

Eran 3.0 -103 822Eran 2.1 -103 516

Value Range: -120~-25

Default Value = -103 (dBm)

Meaning: Indicates the RSCP threshold for event B1 related to coverage-based inter-RAT handover to UTRAN.This parameter specifies the requirement for RSCP of the target UTRAN cell.When the measurement value exceeds this threshold, a measurement report will be sent.

Page 37: FDD Parameter Audit - 20131201

5.11 Inter-RAT – CsfbHoUtranB1ThdRscp

Version Parameter Value No Of Cells

Eran 3.0 -106 822Eran 2.1 -106 516

Value Range: -120~-25

Default Value = -106 (dBm)

Meaning: Indicates the RSCP threshold for event B1, which is used in CS fallback to UTRAN. When CS fallback to UTRAN is applicable, this parameter is set for UEs and used in the evaluation about whether to trigger event B1. This parameter indicates the RSCP requirement for the UTRAN cells to be included in the measurement report. A UE sends a measurement report related to event B1 to the eNodeB when the RSCP in at least one UTRAN cell exceeds this threshold and other triggering conditions are met. For details, see 3GPP TS 36.331.

Page 38: FDD Parameter Audit - 20131201

5.12 Inter-RAT – InterRatHoA1A2TrigQuan

Version Parameter Value No Of eNodeBs

Eran 3.0 RSRP 273Eran 3.0 BOTH 1Eran 2.1 RSRP 170Eran 2.1 BOTH 2

Value Range: RSRP, RSRQ, BOTH

Default Value = RSRP

Meaning: Indicates the quantity used to evaluate the triggering condition for the inter-RAT measurement event A1 or A2. The values are RSRP, RSRQ and BOTH.The measured RSRP values are stable, varying little with the load, and therefore there is little signal fluctuation. The measured RSRQ values vary with the load and are likely to reflect the signal quality of the cell in real time. By default, the reporting quantity for the inter-RAT handover event is BOTH, that is, both RSRP and RSRQ.For details, see 3GPP TS 36.331.

Page 39: FDD Parameter Audit - 20131201

6.Service Throughput

1. Pb2. ReferenceSignalPwr3. DELTAOFFSETRIINDEX

Page 40: FDD Parameter Audit - 20131201

6.1 Service Throughput – Pb

Version Parameter Value No Of Cells

Eran 3.0 1 822Eran 2.1 1 516

Value Range: 0~3

Default Value = 1

Meaning: Indicates the scaling factor index of the Energy Per Resource Element (EPRE) on the PDSCH. This scaling factor is determined by the value of this parameter and the antenna port. For details, see 3GPP TS 36.213.

Page 41: FDD Parameter Audit - 20131201

6.2 Service Throughput – ReferenceSignalPwr

Version Parameter Value No Of Cells

Eran 3.0 182 822Eran 2.1 182 516

Value Range: -600~500

Default Value = 182 (0.1dBm)

Meaning: Indicates the reference signal power of the cell. For details, see 3GPP TS 36.213.

Page 42: FDD Parameter Audit - 20131201

6.3 Service Throughput – DELTAOFFSETRIINDEX

Version Parameter Value No Of eNodeBs

Eran 3.0 5 274

Eran 2.1 Eran 2.1 do not have this para

Value Range: 1~15

Default Value = 5 Eran 3.0

Meaning: Indicates the index mapped to the MCS offset for rank indications (RIs) transmitted with data on PUSCH. The protocol does not recommend the values 13, 14, and 15. If this parameter is set to 13, 14, or 15, If this value is used, the UE performance may deteriorate. For details, see 3GPP TS 36.213.

Page 43: FDD Parameter Audit - 20131201

7.Common Parameter

1. TIMEALIGNMENTTIMER2. PdcchAggLvlCLAdjustSwitch3. CceRatioAdjSwitch4. DrxAlgSwitch

Page 44: FDD Parameter Audit - 20131201

7.1 Common Parameter – TIMEALIGNMENTTIMER

Version Parameter Value No Of Cells

Eran 3.0 SF10240 822

Eran 2.1 Eran 2.1 do not have this para

Value Range: SF500(500 subframes), SF750(750 subframes), SF1280(1280 subframes), SF1920(1920 subframes), SF2560(2560 subframes), SF5120(5120 subframes), SF10240(10240 subframes), INFINITY(Infinity)

Default Value = SF10240

Meaning: Indicates the length of the uplink time alignment timer for UEs in the cell. A UE is considered not time-aligned in the uplink if the timer expires.

Page 45: FDD Parameter Audit - 20131201

7.2 Common Parameter – PdcchAggLvlCLAdjustSwitch

Version Parameter Value No Of Cells

Eran 3.0 ON 813Eran 3.0 OFF 9

Eran 2.1 Eran 2.1 do not have this para

Value Range: OFF, ON

Default Value = ON

Meaning: Indicates the switch used to enable or disable closed-loop adjustment to the PDCCH aggregation level. If this switch is turned on, PDCCH aggregation level is adjusted based on the block error rate (BLER) of the PDCCH. If this switch is turned off, PDCCH aggregation level is not adjusted based on the BLER of the PDCCH.

Page 46: FDD Parameter Audit - 20131201

7.3 Common Parameter – CceRatioAdjSwitch

Version Parameter Value No Of Cells

Eran 3.0 ON 798Eran 3.0 OFF 24Eran 2.1 OFF 516

Value Range: OFF, ON

Default Value = ON Eran 3.0Default Value = OFF Eran 2.1

Meaning: Indicates the CCE ratio adjustment switch for the PDCCH. If this switch is turned on, the resource allocation algorithm of the PDCCH dynamically adjusts the UL and DL CCE ratios within each transmission time interval (TTI) based on CCE usages in UL and DL. If this switch is turned off, the UL and DL CCE ratios are not dynamically adjusted.

Page 47: FDD Parameter Audit - 20131201

7.4 Common Parameter – DrxAlgSwitch

Version Parameter Value No Of Cells

Eran 3.0 ON 20Eran 3.0 OFF 254Eran 2.1 ON 10Eran 2.1 OFF 162

Value Range: OFF, ON

Default Value = OFF

Meaning: Indicates the DRX switch.

Page 48: FDD Parameter Audit - 20131201

Thank You