Polarizers are used in many opticalmeasurements, such as spectral measurementof thin layer species. They are devices that splitunpolarized light into two orthogonal components;one of the linearly polarized components istransmitted, the other is reflected, redirected orabsorbed. The most important features of a goodpolarizer are brightness, contrast and durability.Brightness and contrast can be described bytwo main parameters; K1 and K2.
In the different wavelength regions, polarizersare also available that utilize a thin polymer film orthin optical glass containing oriented silverparticles. For long wave spectroscopy, such asfar-infrared and mm-wave, polarizers with freestanding wound wire grid could be used. Wiregrids are very efficient polarizers with better than99.9% polarization and high transmissionefficiency.
Infrared Polarizers
K1
= Transmission efficiency for normallyincident polarized light whoseelectric field vector isperpendicular to the wire direction.
K2
= Transmission efficiency for normallyincident polarized light whoseelectric field vector is parallel tothe wire direction.
For a ‘perfect polarizer’ K1 = 1, which means fulltransmission of polarized light whose electric fieldvector is in the preferred direction and K2 = 0,which means complete blockage of a beam ofpolarized light whose electric vector isperpendicular to the former. Other measures ofperformance deduced from K1
and K2 are
Degree of polarization =
Extinction Ratio =
Principal transmittance ratio or contrast =
Polarized light can be created by bulk opticalmaterials that have different opticalcharacteristics for the polarized components oflight. Another way of selecting one polarizationis to place a succession of plates made of highindex of refractance materials at the so calledBrewster angle. In the sample compartment ofFT-IR spectrometers there is usually less spaceto accommodate Glan-Taylor, Glan-Thompsonprisms or Brewster angle polarizers.
Holography is another method used to form thefine metallic wire pattern. Two coherent laserbeams are directed onto the surface of the opticalelement which is coated with a very thin layer ofphotoresist. The interference pattern formed atthe intersection of the two beams is allowed toexpose the photoresist. The lines in between theexposed phototresist are removed and thencoated in a vacuum chamber similar to the ruledgrating type. The advantage of holographicpolarizers is that a wider variety of materials canbe used such as the much softer KRS-5. Asmentioned earlier, the efficiency of the polarizerdepends on the grid spacing formed among thewires. Holographic techniques allow moreuniform grid patterns because the spacing isproduced optically. Light scatter due toimperfections of ruled grooves are also reduced.If the grid spacing is smaller, the polarizer is moreefficient. The spacing errors have also muchless effect on the efficiency if the grid is muchsmaller than the wavelength.In the mid-infrared range the most commonly used
polarizers are ruled or holographic. Thepolarization effect comes from the same principleas the free standing wire grid, except the finewires are formed on the surface of an infraredtransmitting optical window material. Polarizationefficiency depends on smaller grid spacing thanthe wavelength and on the conductivity of thewires.In a nutshell, the manufacture of these polarizersis done as follows: In the case of the ruledpolarizer, the surface of the optical element isruled by a diamond needle to form very fine parallellines, such as 1200 lines/mm, on the surface. Theoptical element is then placed in a vacuum chamberand this pattern is partially coated with aluminumor other evaporated metallic layer.The elements are held at an angle relative to thesource so only thin lines of metal are depositedwhere the ruled groove pattern is not shadedfrom the source. The spacing between theevaporated thin lines has to be very small, typicallya fraction of the wavelength. Ruled polarizershave good performance and are durable at highlaser powers, but can only be made on hard,non-granular materials, such as ZnSe, that canbe ruled.
ZnSeInfrared Polarizer
15000 - 500 cm-1
Part Number090-1000
Infrared PolarizersMelissa’s Back!ROI AutomationPolarizer SpecialsPittcon Paper2002 Show Calendar
IN THIS ISSUE
Figure 1
KRS-5 holographic polarizer (a)
KRS-5 holographic polarizer (b)
ZnSe ruled polarizer
CaF2 Holographic polarizer
0
10
20
30
40
50
60
70
80
90
100
%T
2000 Wavenumbers (cm-1)
KRS-5 Holographic polarizer (a)ZnSe Ruled polarizer
CaF2 Holographic polarizer
KRS-5 Holographic polarizer (b)
3500 3000 2500 2000 1500 1000
The trade-off with tighter grid is of course thereduction of the optical throughput. Theseparameters are carefully optimized in the designof the polarizer elements and the right polarizercan be selected for specific experimentalconditions.
The optical material substrate used to create thepolarizers determines the wavelength range thepolarizer can be used. Fig 1 shows the K1 valuesof four selected polarizers. K1 is the ratio of aparallel adjusted polarizer vs. the polarized lightlevel produced by one polarizer. The cutofffrequency of polarizers constructed isdetermined by the optical substrate material ZnSe,KRS-5 and CaF2. The maximum transmitted lightis affected by the transmission of the materialsand the scattering of the ruled and evaporatedsurfaces. The Fresnel losses are determined bythe refractive index and the performance of theanti-reflection coating on the element.
K1/2K2
(K1-K2)(K1+K2)
K1/K2
Comparison of K1 (throughput) of selected polarizers
CaF2Infrared Polarizer10,000 - 1,100 cm-1
Part Number090-1300
PIKE Reflections Page 2
PIKE Technologies Tel: (608) 274-2721 Fax: (608) 274-0103 E-mail: [email protected]
Pittcon Paper
1Presented: Pittcon 2002, New Orleans, March 20022E-mail: [email protected]
Single-Bounce ATR Analysis ofEdible Fats and Oils and Alcoholic
Beverages for Compliance withLabeling Regulations1
Ashraf A. Ismail,2 Robert Cocciardi, andJacqueline Sedman
McGill IR Group, Department of FoodScience and Agricultural Chemistry,Macdonald Campus of McGill University,Ste-Anne-de-Bellevue, Quebec, CanadaH9X 3V9
The McGill IR Group was established in 1990within the Department of Food Science andAgricultural Chemistry of McGill University toinvestigate potential applications of FTIRspectroscopy in food analysis. Our researchprogram has been directed toward meeting thedemand within the food industry for rapid andenvironmentally friendly analytical methods forquality control and process monitoring.
In recent years, we have also been involved inthe development of FTIR methods that can assistthe food industry in complying with food labelingregulations. Two examples of applications fallingwithin this category—the determination of thetrans content of edible fats and oils and theanalysis of alcoholic beverages—are describedin this article. Both of these analyses employ SB-ATR sample-handling accessories and serve toillustrate the utility of the SB-ATR technique in theFTIR analysis of beverages and liquid or semi-liquid food products.
Determination of trans Content of EdibleFats and Oils
Naturally occurring double bonds in fats and oils ofplant origin generally have the cis configuration.However, extensive cis → trans isomerization mayoccur during industrial processing, and the levels oftrans isomers in processed fats and oils can be ashigh as 40%. In recent years, trans fat in the diethas increasingly become of nutritional concern,particularly as a possible risk factor in cardiovasculardisease [1]. In response to this concern, the U.S.FDA submitted a proposal in late 1999 to includetrans fat on food nutrition labels (Figure 1). Althoughthis proposal has not yet been adopted, it hasstimulated interest in the development of accurateand rapid analytical methods for the determinationof the trans content of edible fats and oils.Infrared spectroscopy has been widely employedfor more than 50 years in the fats and oils industryas a routine method for the determination of thetrans content of processed fats and oils. TraditionalIR trans analysis is based on measurement of theintensity of the characteristic absorption of isolated(i.e., nonconjugated) trans bonds at 967 cm-1 (Figure2), assigned to a C—H out-of-plane deformationmode.
(Continued on page 4)
Last PIKE Newsletter !!!
NOT REALLY! The next issue (Spring 2003)will be the last mass-mailed copy. Starting withthe next issue, all copies will be available inPDF format on our website. In addition, anyonewho would like to continue receiving the printedversion can do so by calling, faxing, emailing ormailing us their request. Our goal is to put lesstime and effort into the delivery of the newsletterand more time into the content.
The letters in the Blanks “_” form themissing word in the sentence. Thefollowing are scrambled versions ofcommon FTIR terms.
PPTSREY_SOCOETPRS_CAECFERTNE_CGERIRTRN_AFEOCATM_NENSTRTAMRW_VBAEUN_IDENRAF
IT IS NOT A _ _ _ _ _ _ _ THAT PIKE SHIPSALL ORDERS ON TIME, EVERYTIME.
WordsS R
BAC M E DL
After a few years of staying put inMadison, Melissa is ready to hit theroad again! She’ll be at EAS, somake a point to stop by the booth(Booth #130) and say hello! Notonly will you have the opportunityto congratulate Melissa on herescape from Wisconsin to thebeautiful Garden State of NewJersey, there is a specialpromotional opportunity waitingfor you as well! Melissa is offeringa whopping 40% discount on PIKEMIRacles to all visitors stopping inat the Pike booth. Now you havetwo more great reasons to attendEAS besides taking advantage ofeverything else this show has tooffer, including technical papersand your choice of great seminars.
See you there!
Melissa
Melissa’s Back ! However, the accuracy of this measurement islimited by the proximity of this band to intense oilabsorption bands above 1000 cm-1 that distort thespectral baseline. Furthermore, the measurementof this band is subject to interference fromunderlying weak absorptions of triacylglycerols,which are the predominant species making up allfats and oils. This interference is eliminated byconverting the triacylglycerols to fatty acid methylesters. In addition to this sample preparation step,the traditional IR method requires the quantitativedissolution of the sample in CS2, a noxious andvolatile solvent, to allow it to be injected into afixed-pathlength transmission cell.
PIKE Reflections Page 3
PIKE Technologies Tel: (608) 274-2721 Fax: (608) 274-0103 E-mail: [email protected]
With this information, we are able to estimate thetotal time savings for running 60 samples withPIKE automation. Although no sample preparationtime is saved, using the AutoDiff does mean thelab technician is no longer required to sit by theinstrument during the data collection time, saving60 minutes. In addition, the time to replace the oldsample with the new sample and re-start theinstrument data collection has been reported tosave an addition 30 minutes over the coarse ofrunning 60 samples. So, that’s a total of 90 minutessaved, or $75 per AutoDiff sample tray run (somecustomers reported over 300 minutes saved).So, with the upfront cost difference betweenmanual and automated diffuse reflectanceaccessories being $10,850, the AutoDiff has paidfor itself after 145 fully loaded sample runs.
Of course, the payback in total calendar time willvary depending on the workload of your lab. Asa simple example, if your lab runs an average of60 samples per day, the investment in the addedexpense of the AutoDiff would be in 145 workingdays, or just under 7 months.
Using this example, we calculated the InternalRate of Return (IRR) and the Net Present Value(NPV) for the incremental cost of addingautomation. The IRR is the interest rate receivedfor an investment. The NPV caculates the netpresent value of an investment by using adiscount rate over a period of time (5 years inthis case). The results are as follows:
Internal Rate of Return = 140%Net Present Value = $124,824
(See spreadsheet for details)
In several past issues of PIKE Reflections, wehave presented technical information on theperformance of various FTIR accessories utilizingsample automation. We thought it would be fun toswitch gears this time and look at PIKE automationfrom a financial return on investment perspective.PIKE Technologies is a market leader in the areaof automating FTIR Spectroscopy applications,with products such as our Map300™, MappIR™,XY Autosampler, AutoDiff™, DiskPRO™,andRotatIR™ as well as motorized options for ourVeeMax™, polarizers, and transmission samplewheels. Sometimes we get so wrapped up in thenifty technology, we forget to mention our maingoals in providing the automation in the firstplace………increasing your quality/productivityand SAVING YOU MONEY!
FTIR Sampling Automationcan deliver a big ROI
Automation can be expensive but, as many ofour customers have told us, the payback can bevery fast. Before crunching the numbers on ourROI calculations, we spoke with several of ourexperienced customers currently using PIKEautomation to find out what kind of results theyhave achieved. Then we chose from thisinformation the most conservative results toinclude in our ROI calculations. In some cases,the estimated time savings was 4-5 times greaterthan the example we used. For this example, wechose the PIKE AutoDiff™ Diffuse ReflectanceAccessory compared to the PIKE DiffusIR™, inwhich samples are loaded individually. We hopeyou find it useful in deciding whether automationmay be helpful for you.
The following data and assumptions were usedfor the ROI calculation:
DiffusIR Diffuse Reflectance Accessory US List Price: $4,100AutoDiff Automated Diffuse Reflectance US List Price: $14,950Upfront cost difference between AutoDiff and DiffusIR: $10,850Burdened Cost of Analytical Chemist Lab Technician: $50/hourAverage time to replace old with new sample and re-start data collection: 30 secondsAverage data collection time forrunning typical diffuse reflectance sample: 1 minuteNumber of sample cups on the AutoDiff sample wheel: 60Sample preparation time for DiffusIR and AutoDiff are equalMinimum Useful lifetime of product: 5 yearsAnnual maintenance costs: $1000Initial Training and Installation costs: $2000Average number of working days in a year: 250Discount rate: 10%
Polarizer Special
For a limited time PIKE is dropping the price of ourpolarizers. We are also expanding both ourautomated and manual product lines.
Additional Expense $10,850 $1,000 $1,040 $1,082 $1,125 $1,170
Training Investment $2,000 $0 $0 $0 $0 $0
Labor Cost Savings $0 $18,750 $19,500 $20,280 $21,091 $21,935
Net Cash Flow ($12,850) $17,750 $18,460 $19,198 $19,966 $20,765
Cumulative Cash Flow (12,850) 4,900 23,360 42,558 62,525 83,290
IRR 140.0%Discount Rate, % 10%
NPV $124,824
ROI Spreadsheet
In addition to the time savings in this illustration,many customers have also told us that usingautomation has improved the quality of their workas well. In many cases, errors in the experimentalset-up occurred much less frequently whenautomation of the sample handling was used ascompared to running the samples individually. Thisresults in much less time having to re-run samplesand making the ROI for automation even higher.
Automation is not right for everyone, but as soonas your daily sample load gets into double digits,it’s something to consider. In addition to diffusereflectance, PIKE can provide automation forexperiments using specular reflectance andtransmission. We also provide custom designsto fit your specific sampling needs, so if you haveany questions, do not hesitate to give us a call.
Manual Polarizers090-1000 ZnSe $1950.00090-1100 KRS-5 (a type) $2850.00090-1200 KRS-5 (b type) $3200.00090-1300 CaF2 $2850.00090-1400 BaF2 $3250.00090-1500 Ge $3500.00090-1600 Polyethylene $2400.00090-1700 Polyester $2400.00
Automated Polarizers(includes: Controller, AutoPro Software and Motorized Polarizer)090-2000 ZnSe $4950.00090-2100 KRS-5 (a type) $5850.00090-2200 KRS-5 (b type) $6200.00090-2300 CaF2 $5850.00090-2400 BaF2 $6250.00090-2500 Ge $6500.00090-2600 Polyethylene $5400.00090-2700 Polyester $5400.00
PIKE Reflections Page 4
PIKE Technologies Tel: (608) 274-2721 Fax: (608) 274-0103 E-mail: [email protected]
2901 Commerce Park DriveMadison, Wisconsin 53719
PAID
Eastern Analytical Symposium andExposition (EAS), Garden State ConventionCenter Somerset, New JerseyNovember 18-21, 2002
Booth 130
InfraredPolarizers
Melissa’s Back
ROI Automation
Polarizer Specials
Pittcon Paper
2002 Shows
PIKE 2002 Show Calendar
Prsrt StdU.S. Postage
Permit No. 1547Madison, WI
Pittcon Paper (continued)
Recently, researchers at the U.S. FDA developed anew FTIR method to address the need for a rapidand convenient means of measuring the transcontent of fats, oils, and fat-containing foods [2].Following an international collaborative study [3],in which we participated, this method was adoptedas an official method by the American Oil Chemists’Society (AOCS) in 1999 and by the Association ofOfficial Analytical Chemists (AOAC) in 2000.The cornerstones of the method are (i) the use ofthe SB-ATR sample-handling technique to allowsamples to be analyzed in their neat form (i.e.,without the use of a solvent) and (ii) removal ofspectral interferences by ratioing the spectrum of
3500 3000 2500 2000 1500 10000.00
0.05
0.10
0.15
0.20
0.25
0.30
Isolatedtransbonds
Abso
rban
ce
Wavenumber (cm-1)Nutrition labelconforming to thea m e n d m e n t sproposed by the U.S.FDA. The trans fatcontent is included inthe amount statedforsaturated fat andis also reportedseparately in afootnote.
The second installment of the McGillPaper will be in the spring issue.
Section two includes: Determination of Alcohol Contentof Distilled Liquors and Wines
Figure 1
Thus, it may be anticipated that it will findextensive use in the food industry if and when theproposed amendments to nutrition labelingrequirements with respect to trans fat are adopted.We have also demonstrated the extension of thisFTIR/SB-ATR analytical methodology to thedetermination of quality parameters of fats andoils [5], and this in turn should provide an impetusfor the wider application of FTIR/SB-ATR analysisin the fats and oils sector.
the sample against that of an appropriate trans-freereference oil having a fatty acid composition similarto that of the sample [4]. The determination oftrans content is based on the area of the 967 cm-1
peak, which can be measured accurately owing tothe straightening of the baseline and the eliminationof underlying triacylglycerol absorptions by theratioing procedure. The lower limit of quantitationestablished in the collaborative study was 5% trans[3]. For the analysis of fats, the SB-ATR crystalmust be heated to 65 ± 2oC to ensure that samplesare fully melted, and thus the excellent temperaturecontrol that can be achieved owing to the smallsurface area of the crystal is a key advantage of thissample-handling technique. Furthermore, less than50 µL of sample is required, making the methodsuitable for the analysis of small amounts of fatextracted from low-fat foods. The method is simpleand convenient, requiring no sample preparation,and the total analysis time is on the order of 2-3min/sample.