Extron OCS 100 specifications · Extron OCS 100 Occupancy Sensors • Specifications 1...
Transcript of Extron OCS 100 specifications · Extron OCS 100 Occupancy Sensors • Specifications 1...
1Extron OCS 100 Occupancy Sensors • Specifications
SpecificationsOCS 100 Occupancy Sensors
OCS 100CSquare feet coverage area ������������� 2000 square feet
32'(10 m)
23'(7 m)
64'(20 m)
45'(14 m)
12'(4 m)
22'(7 m)
U.S. Patents: 6151529, 5946209, 5699243, 5640143, 6415205,
6078253, D404326, 6222191, 5986357, 6759954
67E4
Appliance C
ontrol
3(m
ax Disabled)
Threshold
Not U
sed
OCS 100C
68-3155-52 Rev. A
Extro
n Head
quarters
+1.800.633.9876 (Insid
e US
A/C
anada O
nly)E
xtron U
SA
- West
+1.714.491.1500
+1.714.491.1517 FA
X
ww
w.extro
n.com
Center ofSensor Coverage
Sensor CoverageUS Minor Motion
US Major Motion
IR Minor Motion
IR Major Motion
NOTE: These coverage dimensions are achieved when the OCS 100C is installed 10 ft (3�04 m) above the coverage area�
OCS 100WSquare feet coverage area ������������� 1600 square feet
32'(10 m)
23'(7 m)
32'(10 m)
23'(7 m)
40'(12 m)
20'(6 m)
40' (12 m) MajorMotion Coverage
20' (6 m) MinorMotion Coverage
10' (3 m) MountingHeight
Sensor CoverageUS Minor Motion
US Major Motion
IR Minor Motion
IR Major Motion
2
Specification • OCS 100 Occupancy Sensors (Continued)
Extron OCS 100 Occupancy Sensors • Specifications
SensorInteliDAPT® technology ����������������� Auto reset from test setting
Self-adjusting timer Self-adjusting passive infrared thresholds Automatic false-on and false-off correction
LED lamp ��������������������������������������� Red - infrared motion Green - ultrasonic detection
Timer timeoutOCS 100C ������������������������������ Automatic mode: 8 to 42 minutes (self-adjusts based on occupancy)
Manual mode: 8 to 42 minutes Test mode: 8 seconds
OCS 100W ������������������������������ Automatic mode: 4 to 30 minutes (self-adjusts based on occupancy) Manual mode: 4, 8, 15 and 30 minutes Test mode: 8 seconds
Ultrasonic (US)OCS 100C ������������������������������ 4 sensors - 32 kHz outputOCS 100W ������������������������������ 2 sensors - 32 kHz output
Passive infrared (PIR)OCS 100C ������������������������������ Dual-element pyrometer and 12-element cylindrical segmented Fresnel lens,
integral filter excludes excess PIR energy from sunlightOCS 100W ������������������������������ Dual-element pyrometer and 12-element cylindrical rugged lens
RelayRelay ��������������������������������������������� 1 Normally Open and Closed contact, single pole, double throw 500 mA rated at
24 VDC, three-wire isolated relay
PhotocellPhotocell ���������������������������������������� Adjustable natural-light override ranges from 1 to 100 foot-candles (10 to 1000
Lux)
Adaptive functionsLearning ����������������������������������������� 4 weeks for response error conditions, air current adaption and timer optimizationPost-learning occupancy periods ��� 24-hour circadian occupancy periods learnedAdjustments in post-learning period �������������������������������������������� Generally occupied periods
Generally unoccupied periods
Digital outputQuantity/type ��������������������������������� 2 digital outputsConnectors ������������������������������������ Blue wire = Occupancy only
Gray wire = Occupancy + PhotocellOutput voltage range ��������������������� 0 - 24 VDC
Active high logic control signal with short-circuit protection, open collector when unoccupied
GeneralSensor power input requirements��� 20-24 VDC, 33 mA nominal
NOTE: If power is supplied by an optional 12 VDC power supply, then use the included PC 1224 to convert 12 VDC to 24VDC�
PC 1224 power requirements �������� Input: 12 VDC, 1�5 A max Output: 12 VDC, 1�25 A max 24 VDC, 75 mA max
Wiring �������������������������������������������� Color coded, pre-stripped leads - 6" (15 am) in total lengthTemperature/humidity �������������������� Operation: +32 to +104 °F (0 to +40 °C) / 0% to 95 %, noncondensing
For indoor use onlyCooling ������������������������������������������ Convection, no vents
3
Specification • OCS 100 Occupancy Sensors (Continued)
Extron OCS 100 Occupancy Sensors • Specifications
Mounting ��������������������������������������� Mounting base provided Recommended mounting height: 8 feet with a max mounting height of 12 feet
Enclosure type ������������������������������� PlasticEnclosure dimensions
OCS 100C ������������������������������ 4�5" W x 1�4" D (114 mm W x 38 mm D)
1.4"(36 mm)
4.5"(114 mm)
OCS 100W ������������������������������ 2�8" W x 5�5" L x 2�1" D (71 mm W x 140 mm x 53 mm D)
5.5"(140 mm)
3.7"(94 mm)
3.9"(99 mm)
2.8"(71 mm)
2.1"(53 mm)
PC 1224 ���������������������������������� 1�0" W x 1�0" L x 0�5" D (25�4 mm W x 25�4 mm L x 12�7 mm D)
Product weight ������������������������������ 0�1 lb (<0�1 kg)Color ���������������������������������������������� Off-whiteVibration ���������������������������������������� ISTA 1A in carton (International Safe Transit Association)Regulatory compliance
Safety �������������������������������������� CE, c-UL, ULEMI/EMC ��������������������������������� CE, FCC Class AEnvironmental �������������������������� Complies with the appropriate requirements of RoHS, WEEE, and California Title
24Warranty ���������������������������������������� 3 years parts and labor
4
Specification • OCS 100 Occupancy Sensors (Continued)
Extron Headquarters+800.633.9876 Inside USA/Canada Only
Extron USA - West Extron USA - East+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia+65.6383.4400
+65.6383.4664 FAX
Extron Japan+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East+971.4.299.1800
+971.4.299.1880 FAX
Extron Australia+61.8.8113.6800+61.8.8351.2511 FAX
Extron India1800.3070.3777
(Inside India Only)
+91.80.3055.3777
+91.80.3055.3737 FAX
© 2017 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
NOTE: Specifications are subject to change without notice�
NOTE: Shipping weights and dimensions are available at www.extron.com�