Etap12 NewFeature Capabilities 2013

download Etap12 NewFeature Capabilities 2013

of 2

Transcript of Etap12 NewFeature Capabilities 2013

  • 7/28/2019 Etap12 NewFeature Capabilities 2013

    1/2

    The Future of Power System

    Engineering & Operation Today

    ETAP 12 release is the latest upgrade of the market-leading

    electrical power system design and operation software. The new

    analysis features and enhanced capabilities effectively enable

    optimized design, increasing safety, quality, and productivity.

    ETAP 12 Faster Than Real-TimeTM solution provides for better

    decision making, improved operations management, cost

    saving, and compliancy.

    As the industrys market leader, ETAP delivers the future of

    power systems engineering and operation - today.

    Innovation

    Automation

    Collaboration

    New Features

    & Capabilities

  • 7/28/2019 Etap12 NewFeature Capabilities 2013

    2/2

    Elements & Database

    Auto-Connect

    Automatic equipment connection mode

    Automated selection of available pins

    Auto connection to closest highlighted

    element

    Auto Disconnect & Reconnect

    Switching Device

    Interlock Enforcer Auto enforcement of switching

    interlock logics

    Automatic pre & post switchinglogicverication

    Interlock based on circuit breakerpositions or meter readings

    Automaticinterlockconictchecking

    Ability to model cascade control of

    switching devices

    Active monitoring of switching interlock

    violations

    Switching plan validation against

    hazardous actions

    Integrated operation with Switching

    Sequence Management

    Cable Manager

    Batch cable management

    Customizable cable reports

    Multi-cable sizing & shock protection

    evaluation

    Intelligentsearch/ltering

    Cable System

    Automatic cable sequence

    impedance calculation

    Cable Constants

    Cable Armor thermal calculation

    Cable Sheath thermal calculation

    Calculations based on BS 5467,

    BS 7671 & IEC 60364s

    Multiple Language Support

    Interface & Help File in six languages:

    - English - Chinese

    - Portuguese - Japanese- Russian - Spanish

    Output reports in seven languages:

    - English - Chinese- Portuguese - Japanese

    - Russian - Spanish

    - German

    Photovoltaic (PV) Panels

    Discrete DC PV panel element

    Constant current source modeling

    Model individual PV panels

    Detailed modeling considers string

    cables & combiner boxes

    AC & DC system analysis

    Extensive Manufacturer / Model library

    Modeling based on P-V & I-V curves

    License Borrowing

    Network license checkout

    License Borrowing Manager

    Flexible License Borrowing duration

    LicenseCongurationUtility

    Polyline Textbox

    Freehand polyline shapes & styles

    Graphicallydenerevisionboundaries

    Dynamic textbox object

    Save with OLV Templates

    Data Exchange - DataX Legacy program conversion to ETAP

    Automatic one-line creation

    Protective device library mapping

    Convertusingnativeleformats

    Built-in conversions for SKM

    Dapper & Captor, PSSE,EasyPower

    Project Merge

    Multi-user project management

    Parallel ETAP project development

    Self contained snapshots of the

    parent & branch projects

    Merge Base & Revision Data

    Merge TCCs Views

    Transformer

    2W & 3W buried Delta transformer

    Calculation of zero sequence based on

    test data

    Core & Shell type construction

    3L, 4L & 5L models

    Engineering Libraries

    NewVeried&Validatedlibrarydata

    4,800 newly added library devices:

    - Circuit Breakers - Relays- Trip Devices - Fuses

    - Cables - Harmonic Source

    Interharmonics

    Interharmonic modeling & simulation

    Performvoltageickerlimitationstudies

    Interharmonic distortion indices: IEC 61000

    Handling of harmonics up to 250th order

    Automatic interharmonic frequency generat

    Auto harmonic spectrum generation: IEEE

    Adjustable harmonic current base

    Adaptive Newtown-Raphson method

    Open Phase Fault

    Series fault or open phase condition model

    Load Flow

    Adaptive Newton-Raphson method

    Fast convergence for systems with negligib

    impedance

    Handling of transmission series compensat

    AC Arc Flash Analysis

    3 & 1-Phase Arc Flash Sequence-of-Opera

    Graphical display of protective device tripsequence

    Vericationofdevicedutypriortoarcash

    calculations

    Enhanced source protective device capabil

    Enhanced Arc Flash result analyzer

    User-denedincidentenergycorrectionfac

    Enhanced display of results on the one-line

    diagram

    DC Arc Flash Analysis

    Maximum power method

    Stokes & Oppenlander method Paukert me

    Determine incident energy

    Assessarcashprotectionboundary

    Customizearcashlabels

    DC Arc Flash result analyzer

    T 800.477.ETAP | T 949.900.1000

    etap.com

    2013 ETAP. All rights reserved. Certain names and/or logos used in this document may constitute

    trademarks, service marks, or trade names of ETAP. Other brand and product names are trademarks oftheir respective holders. B2-E12-0113-10

    New

    New New

    New

    New

    New

    Enhanced

    Enhanced

    Enhanced

    Enhanced

    Enhanced

    Enhanced

    Enhanced

    Enhan

    Enhanced

    New

    ETAP Real-TimePower System Monitoring & Simulatio

    Predictive simulation from web clients

    Dynamicalarmnotication

    Enhanced web dashboards

    Geospatial HMI views with real-time data

    Unifed Architecture

    Web-based visualization & control

    Thin client support via IEC 62541 standards

    Secured communication for web clients

    Intelligent Fast Load Shedding

    Breaker failure detection & management

    Analysis Modules

    New