The Future of Power System
Engineering & Operation Today
ETAP 12 release is the latest upgrade of the market-leading
electrical power system design and operation software. The new
analysis features and enhanced capabilities effectively enable
optimized design, increasing safety, quality, and productivity.
ETAP 12 Faster Than Real-TimeTM solution provides for better
decision making, improved operations management, cost
saving, and compliancy.
As the industrys market leader, ETAP delivers the future of
power systems engineering and operation - today.
Innovation
Automation
Collaboration
New Features
& Capabilities
-
7/28/2019 Etap12 NewFeature Capabilities 2013
2/2
Elements & Database
Auto-Connect
Automatic equipment connection mode
Automated selection of available pins
Auto connection to closest highlighted
element
Auto Disconnect & Reconnect
Switching Device
Interlock Enforcer Auto enforcement of switching
interlock logics
Automatic pre & post switchinglogicverication
Interlock based on circuit breakerpositions or meter readings
Automaticinterlockconictchecking
Ability to model cascade control of
switching devices
Active monitoring of switching interlock
violations
Switching plan validation against
hazardous actions
Integrated operation with Switching
Sequence Management
Cable Manager
Batch cable management
Customizable cable reports
Multi-cable sizing & shock protection
evaluation
Intelligentsearch/ltering
Cable System
Automatic cable sequence
impedance calculation
Cable Constants
Cable Armor thermal calculation
Cable Sheath thermal calculation
Calculations based on BS 5467,
BS 7671 & IEC 60364s
Multiple Language Support
Interface & Help File in six languages:
- English - Chinese
- Portuguese - Japanese- Russian - Spanish
Output reports in seven languages:
- English - Chinese- Portuguese - Japanese
- Russian - Spanish
- German
Photovoltaic (PV) Panels
Discrete DC PV panel element
Constant current source modeling
Model individual PV panels
Detailed modeling considers string
cables & combiner boxes
AC & DC system analysis
Extensive Manufacturer / Model library
Modeling based on P-V & I-V curves
License Borrowing
Network license checkout
License Borrowing Manager
Flexible License Borrowing duration
LicenseCongurationUtility
Polyline Textbox
Freehand polyline shapes & styles
Graphicallydenerevisionboundaries
Dynamic textbox object
Save with OLV Templates
Data Exchange - DataX Legacy program conversion to ETAP
Automatic one-line creation
Protective device library mapping
Convertusingnativeleformats
Built-in conversions for SKM
Dapper & Captor, PSSE,EasyPower
Project Merge
Multi-user project management
Parallel ETAP project development
Self contained snapshots of the
parent & branch projects
Merge Base & Revision Data
Merge TCCs Views
Transformer
2W & 3W buried Delta transformer
Calculation of zero sequence based on
test data
Core & Shell type construction
3L, 4L & 5L models
Engineering Libraries
NewVeried&Validatedlibrarydata
4,800 newly added library devices:
- Circuit Breakers - Relays- Trip Devices - Fuses
- Cables - Harmonic Source
Interharmonics
Interharmonic modeling & simulation
Performvoltageickerlimitationstudies
Interharmonic distortion indices: IEC 61000
Handling of harmonics up to 250th order
Automatic interharmonic frequency generat
Auto harmonic spectrum generation: IEEE
Adjustable harmonic current base
Adaptive Newtown-Raphson method
Open Phase Fault
Series fault or open phase condition model
Load Flow
Adaptive Newton-Raphson method
Fast convergence for systems with negligib
impedance
Handling of transmission series compensat
AC Arc Flash Analysis
3 & 1-Phase Arc Flash Sequence-of-Opera
Graphical display of protective device tripsequence
Vericationofdevicedutypriortoarcash
calculations
Enhanced source protective device capabil
Enhanced Arc Flash result analyzer
User-denedincidentenergycorrectionfac
Enhanced display of results on the one-line
diagram
DC Arc Flash Analysis
Maximum power method
Stokes & Oppenlander method Paukert me
Determine incident energy
Assessarcashprotectionboundary
Customizearcashlabels
DC Arc Flash result analyzer
T 800.477.ETAP | T 949.900.1000
etap.com
2013 ETAP. All rights reserved. Certain names and/or logos used in this document may constitute
trademarks, service marks, or trade names of ETAP. Other brand and product names are trademarks oftheir respective holders. B2-E12-0113-10
New
New New
New
New
New
Enhanced
Enhanced
Enhanced
Enhanced
Enhanced
Enhanced
Enhanced
Enhan
Enhanced
New
ETAP Real-TimePower System Monitoring & Simulatio
Predictive simulation from web clients
Dynamicalarmnotication
Enhanced web dashboards
Geospatial HMI views with real-time data
Unifed Architecture
Web-based visualization & control
Thin client support via IEC 62541 standards
Secured communication for web clients
Intelligent Fast Load Shedding
Breaker failure detection & management
Analysis Modules
New