Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit...

22
RESIDENTIAL VERTICAL CLADDING Espan 340™ / 470™ RVEP 0800 ROOFNZ (0800 766 369) www.metalcraftgroup.co.nz Architectural / Specification Enquiries Ph: 09 274 0408 Mobile: 027 603 1096 Email: [email protected] 00 / 21 COVER SHEET 01 / 21 PARAPET AND BALUSTRADE CAPPING 02 / 21 SCUPPER W/ RAINWATER HEAD 03 / 21 SOFFIT 04 / 21 BUTT WINDOW HEAD 05 / 21 BUTT WINDOW SILL 06 / 21 BUTT WINDOW JAMB 07 / 21 RECESSED WINDOW HEAD 08 / 21 RECESSED WINDOW SILL 09 / 21 RECESSED WINDOW JAMB 10 / 21 METERBOX HEAD 11 / 21 METERBOX SILL 12 / 21 METERBOX JAMB 13 / 21 INTERNAL CORNER 14 / 21 EXTERNAL CORNER 15 / 21 SOAKER FLASHING 16 / 21 CHANGE IN CLADDING 17 / 21 CLADDING ABUTMENT 18 / 21 BOTTOM OF CLADDING (FLUSH) 19 / 21 BOTTOM OF CLADDING (RECESSED) 20 / 21 3D WINDOW FLASHINGS 21 / 21 3D RAINWATER HEAD DETAIL LIST

Transcript of Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit...

Page 1: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

RESIDENTIAL VERTICAL CLADDING

Espan 340™ / 470™

RVEP

0800 ROOFNZ (0800 766 369)www.metalcraftgroup.co.nz

Architectural / Specification EnquiriesPh: 09 274 0408

Mobile: 027 603 1096Email: [email protected]

00 / 21 COVER SHEET01 / 21 PARAPET AND BALUSTRADE CAPPING02 / 21 SCUPPER W/ RAINWATER HEAD03 / 21 SOFFIT04 / 21 BUTT WINDOW HEAD05 / 21 BUTT WINDOW SILL06 / 21 BUTT WINDOW JAMB07 / 21 RECESSED WINDOW HEAD08 / 21 RECESSED WINDOW SILL09 / 21 RECESSED WINDOW JAMB10 / 21 METERBOX HEAD11 / 21 METERBOX SILL12 / 21 METERBOX JAMB13 / 21 INTERNAL CORNER14 / 21 EXTERNAL CORNER15 / 21 SOAKER FLASHING16 / 21 CHANGE IN CLADDING17 / 21 CLADDING ABUTMENT18 / 21 BOTTOM OF CLADDING (FLUSH)19 / 21 BOTTOM OF CLADDING (RECESSED)20 / 21 3D WINDOW FLASHINGS21 / 21 3D RAINWATER HEAD

DETAIL LIST

Page 2: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

PRE-FINISHED PARAPET CAP FLASHINGNO FIXINGS ON TOP OF FLASHING

PERMEABLE WALL UNDERLAY, SHOWNDASHED

PRE-FINISHED SELFDRILLING/TAPPING SCREW WITHRUBBER WASHER FOR FIXING TOPOF ESPAN™ CLADDING

METALCRAFT ESPAN™VERTICAL CLADDING

WALL FRAMING

CONTINUOUS TIMBER PACKING

MIN

. 5.00°

PROVIDE SEPARATION OF METAL CAPPING ANDTIMBER AS REQUIRED WITH DPC, SHOWNDASHED

CLE

ARAN

CE

3 m

m M

IN

CLE

ARAN

CE

25m

m M

IN

PRE-FINISHED POP RIVET BEDDEDIN SILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW

STOPENDS TO WALL CLADDING

COMPRESSIBLE FOAM SEAL. REFERTO MRM CODE OF PRACTICE VERSION2.2 /2012 FOR REQUIRMENT.

20mm HORIZONTAL CAVITY BATTEN

5mm GAP

CLE

A RAN

CE

25m

m M

IN

5mm GAP5mm GAP

MIN

. 5.00 °

ALTERNATIVE OPTION

Z

Z

Z

CATEGORY A

1. NORMAL EXPOSURE2. ROOF PITCH >10°

MIN. 50mm (VERTICALLY DOWN FACE - SMOOTH)

MIN. 75mm (VERTICALLY DOWN FACE - PROFILED)

CATEGORY B

1. EXPOSED (HIGHER RISK) & WIND LOAD EXCEEDS 1.5 kPa.2. ROOF PITCH <10°

MIN. 75mm (VERTICALLY DOWN FACE - SMOOTH)

MIN. 100mm (VERTICALLY DOWN FACE - PROFILED)

Z

ALTERNATIVE SOLUTION AS PER MRM CODE OF PRACTICE

SITUATION 1

1. LOW, MEDIUM, HIGH WINDZONES, WHERE ROOF PITCH ≥ 10°

MIN. 50mm

SITUATION 2

1. ALL ROOF PITCHES IN VERY HIGHWIND ZONE2. LOW, MEDIUM, HIGH WIND ZONESWHERE ROOF PITCH ≤ 10°

MIN. 70mmZ

SITUATION 3

1. FOR ALL ROOF PITCHES INEXTRA HIGH WIND ZONES

MIN. 90mm

ACCEPTABLE SOLUTION AS PER E2/ASI

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet 1 : 2

PARAPET AND BALUSTRADE CAPPING

01 / 212018

Page 3: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

METALCRAFT ESPAN™ VERTICALCLADDING

METALCRAFT ESPAN™ VERTICALCLADDING PERMEABLE WALL UNDERLAY,

SHOWN DASHED

20mm HORIZONTAL CAVITYBATTEN

WALL FRAMING

CAVITY CLOSER

RETURN MEMBRANE INTORAINWATER HEAD

CONTINUOUS MEMBRANEDRESSED THROUGH BASE ANDUP SIDES OF OPENING WITHUPPER EDGES SEALED AGAINSTCLADDING. RETURN ALONGBACK OF RAINWATERHEAD

RAINWATER HEAD

RETURN MEMBRANEAT END OF LIP

MEMBRANE ON ROOF SUBSTRATE

8g WAFER-TEK SCREW

TRUE ROOF LINE BEHIND

PRE FINISHED SCREW WITHRUBBER WASHER

25RAINWATER HEADOVERFLOW BELOWOPEINING LEVEL,1.5 xCROSS-SECTIONDOWNPIPE DIAMETER

50 mm

SEPARATE BATTEN AND CLADDINGAS REQUIRED WITH DPC

ALTERNATIVE OPTIONMETALCRAFT ESPAN™ CLIP SYSTEMWITH 12G x 16mm WAFERTEK

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet 1 : 2

SCUPPER W/ RAINWATER HEAD

02 / 212018

Page 4: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

FLY RAFTER

BARGE BOARD

SOFFIT LINING

PURLIN

INTERNAL CEILING LINING

SQUARE STOP CORNICE

EXTRA NOG FOR TOP FIXING OFWALL CLADDING

MIN. 50mm

PERMEABLE WALL UNDERLAY,SHOWN DASHED

WALL FRAMING

METALCRAFT ESPAN™ VERTICALCLADDING

COMPRESSIBLE FOAM SEAL. REFER TO MRM CODEOF PRACTICE VERSION 2.2 /2012 FOR REQUIRMENT.

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

PRE-FINISHED SOFFIT FLASHING

20mm HORIZONTAL CAVITY BATTEN

STOPENDS TO WALL CLADDING

INTERNAL WALL LINING

PRE-FINISHED POP RIVET BEDDEDIN SILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW

SEPARATE BATTEN AND CLADDING ASREQUIRED WITH DPC

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER FORFIXING TOP OF ESPAN™ CLADDING

100m

m M

IN

5mm GAP

MIN. 50mm

100m

m M

IN

5mm GAP

ALTERNATIVE OPTION

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet 1 : 2

SOFFIT

03 / 212018

Page 5: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

PERMEABLE WALL UNDERLAY DRESSED INTOOPENING WITH FLEXIBLE FLASHING TAPEINSTALLED OVER WRAP TO CORNERS AT HEAD

TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING

WINDOW LINTEL FRAMING

PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL

DOUBLE GLAZING WINDOW JOINERY

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

WINDOW HEAD LINER

LINE OF WINDOW JAMB LINER BEHIND

STOPENDS TO HEAD FLASHING

LINE OF JAMB FLASHING BEHIND

EXTRA PERMEABLE WALL UNDERLAYOVER WINDOW HEAD FLASHING, SHOWNDASHED

INTERNAL WALL LINING

STST OR GALV. FLAT HEAD NAIL FORFLASHING

METALCRAFT ESPAN™ VERTICALCLADDING

PERMEABLE WALL UNDERLAY, SHOWNDASHED

METALCRAFT ESPAN™ CLIP SYSTEMWITH 12G x 35mm SCREWS

CAVITY CLOSER AS REQUIRED TO NZBC

MIN

. 10m

m C

OVE

R

SUG

GES

T M

IN. 5

0mm

DIM

ENSI

ON

TO

SU

IT

5mm

GAP

DR

IP E

DG

E TO

CLA

DD

ING

MIN

.15m

m

MIN

.75m

m W

ITH

OU

T H

EM E

DG

E

MIN

.50m

m C

OVE

R

5mm GAP

20mm HORIZONTAL CAVITY BATTEN

5mm

GAP

MIN

. 10m

m C

OVE

R

SUG

GES

T M

IN. 5

0mm

DIM

ENSI

ON

S TO

SU

ITDR

IP E

DG

E TO

CLA

DD

I NG

MIN

. 15m

m

MIN

. 75m

m W

I TH

OU

T H

EM E

DG

E

MIN

. 50m

m C

OVE

R

ALTERNATIVE OPTION

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet 1 : 2

BUTT WINDOW HEAD

04 / 212018

Page 6: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

STOPENDS TO SILL FLASHING

LINE OF WINDOW JAMB LINER BEHIND

MIN. 8mm PACKER

WINDOW SILL LINER

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

PRE-FINISHED WINDOW SILL FLASHING

LINE OF JAMB FLASHING BEHIND

WINDOW SILL SUPPORT BAR

5mm GAP

MIN

.8m

m C

OVE

R

FLEXIBLE FLASHING TAPE OVER PERMEABLEWALL UNDERLAY FOR FULL WIDTH/DEPTH SILL

DOUBLE GLAZING WINDOW JOINERY

5mm

GAP

METALCRAFT ESPAN™ VERTICALCLADDING

PERMEABLE WALL UNDERLAY,SHOWN DASHED STOPENDS TO WALL CLADDING

WALL FRAMING

INTERNAL WALL LINING

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER FOR FIXINGTOP OF ESPAN™ WALL CLADDING

PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW20mm HORIZONTAL CAVITY BATTEN

CO

VER

CLA

DD

ING

60m

m

COMPRESSIBLE FOAM SEAL. REFERTO MRM CODE OF PRACTICEVERSION 2.2 /2012 FORREQUIRMENT.

SEPARATE BATTEN AND CLADDING WITHDPC AS REQUIRED

5mm

GAP

CO

V ER

CLA

DD

ING

60m

m

MIN

. 8m

m C

OVE

R

5mm GAP

5mm GAP

ALTERNATIVE OPTION

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet

- DEPENDING ON ACTUAL SITUATION, A SECONDARY FLASHINGMAY BE REQUIRED. REFER METALCRAFT ROOFING FOR MOREINFORMATION.

1 : 2

BUTT WINDOW SILL

05 / 212018

Page 7: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

5mm GAP

MIN.10mm COVER

SUGGEST MIN. 50mm

DIMENSION TO SUIT

PERMEABLE WALL UNDERLAY,SHOWN DASHED

DOUBLE GLAZING WINDOW JOINERY

LINE OF WINDOW SILL LINER BELOW

WINDOW JAMB LINER

TIMBER PACKER

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB

20mm JAMB BATTEN

INTERNAL WALL LINING

PRE-FINISHED SECONDARYFLASHING

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

FLEXIBLE FLASHING TAPE OVER PERMEABLEWALL UNDERLAY FOR FULL WIDTH/DEPTHSILL

LINE OF HEAD FLASHING ABOVE

PRE-FINISHED WINDOW JAMBFLASHING

SEPARATE BATTEN AND FLASHINGWITH DPC AS REQUIRED

LINE OF SILL FLASHING BELOW

LINE OF HEAD FLASHING ABOVE

PRE-FINISHED 8g WAFER-TEKSCREW WITH EPDM WASHER

METALCRAFT ESPAN™VERTICAL CLADDING

5mm

GAP

PRE-FINISHED FIXING BRACKET WITH PRE-FINISHED POP RIVET BEDDED IN SILICONEOR PRE-FINISHED 8g WAFER-TEK SCREW

20mm HORIZONTALCAVITY BATTEN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet

- DEPENDING ON ACTUAL SITUATION, A SECONDARY FLASHINGMAY BE REQUIRED. REFER METALCRAFT ROOFING FOR MOREINFORMATION.

1 : 2

BUTT WINDOW JAMB

06 / 212018

Page 8: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

PERMEABLE WALL UNDERLAY DRESSEDINTO OPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TO CORNERSAT HEAD

TEMPORARY PACKER IF REQUIRED,REMOVED AFTER FIXING

WINDOW LINTEL FRAMING

PRE-FINISHED WINDOW HEADFLASHING WITH 15° FALL

DOUBLE GLAZING WINDOW JOINERY

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

WINDOW HEAD LINER

LINE OF WINDOW JAMB LINER BEHIND

STOPENDS TO HEAD FLASHING

LINE OF JAMB FLASHING BEHINDM

IN. 1

0mm

CO

VER

EXTRA PERMEABLE WALL UNDERLAYOVER WINDOW HEAD FLASHING, SHOWNDASHED

INTERNAL WALL LINING

STST OR GALV. FLAT HEAD NAIL FORFLASHING

METALCRAFT ESPAN™ VERTICALCLADDING

PERMEABLE WALL UNDERLAY, SHOWNDASHED

METALCRAFT ESPAN™ CLIP SYSTEM WITH12G x 35mm SCREWS

CAVITY CLOSER AS REQUIRED TO NZBC

SUG

GES

T M

IN.5

0mm

DIM

ENSI

ON

TO

SU

IT

5mm

GAP

MIN

.75m

m W

ITH

OU

T H

EM E

DG

E

MIN

. 50m

m C

OVE

R

DR

IP E

DG

E TO

CLA

DD

ING

MIN

.15m

m G

AP

20mm HORIZONTAL CAVITY BATTEN

5mm

GAP DR

IP E

DG

E TO

CLA

DD

I NG

MIN

15m

m G

AP

MIN

. 75m

m W

I TH

OU

T H

EM E

DG

E

MIN

. 50m

m C

OVE

R

SUG

GES

T M

IN. 5

0mm

DIM

ENSI

ON

TO

SU

IT

10m

m M

IN C

OVE

R

ALTERNATIVE OPTION

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet 1 : 2

RECESSED WINDOW HEAD

07 / 212018

Page 9: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

STOPENDS TO SILL FLASHING

LINE OF WINDOW JAMB LINER BEHIND

MIN. 8mm PACKER

WINDOW SILL LINER

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

PRE-FINISHED WINDOW SILL FLASHING

LINE OF JAMB FLASHING BEHIND

WINDOW SILL SUPPORT BAR

FLEXIBLE FLASHING TAPE OVER PERMEABLEWALL UNDERLAY FOR FULL WIDTH/DEPTH SILL

DOUBLE GLAZING WINDOW JOINERY

METALCRAFT ESPAN™ VERTICALCLADDING

PERMEABLE WALL UNDERLAY,SHOWN DASHED

STOPENDS TO WALL CLADDINGWALL FRAMING

INTERNAL WALL LINING

SEPARATE BATTEN AND CLADDING WITHDPC AS REQUIRED

PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW

PRE-FINISHED SECONDARY FLASHING

20mm HORIZONTAL CAVITY BATTEN

PRE-FINISHED SELF DRILLING/TAPPING SCREWWITH RUBBER WASHER FOR FIXING TOP OFESPAN™ CLADDING C

OVE

R C

LAD

DIN

G

60m

m

5mm GAP

5mm

GAP

MIN

. 8m

m C

OVE

R

COMPRESSIBLE FOAM SEAL. REFERTO MRM CODE OF PRACTICE VERSION2.2 /2012 FOR REQUIRMENT.

5mm GAP

CO

VER

CLA

DD

ING

60m

m

5mm

GAP

MIN

. 8m

m C

OVE

R

ALTERNATIVE OPTION

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet

- DEPENDING ON ACTUAL SITUATION, A SECONDARY FLASHINGMAY BE REQUIRED. REFER METALCRAFT ROOFING FOR MOREINFORMATION.

1 : 2

RECESSED WINDOW SILL

08 / 212018

Page 10: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

5mm GAP

MIN. 10mm COVER

SUGGEST MIN. 50mm

DIMENSION TO SUIT

PERMEABLE WALL UNDERLAY,SHOWN DASHED

DOUBLE GLAZING WINDOW JOINERY

LINE OF WINDOW SILL LINER BELOW

WINDOW JAMB LINER

TIMBER PACKER

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB

20mm JAMB BATTEN

INTERNAL WALL LINING

PRE-FINISHED SECONDARYFLASHING

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

FLEXIBLE FLASHING TAPE OVER PERMEABLEWALL UNDERLAY FOR FULL WIDTH/DEPTHSILL

LINE OF HEAD FLASHING ABOVE

PRE-FINISHED WINDOW JAMBFLASHING

SEPARATE BATTEN AND FLASHINGWITH DPC AS REQUIRED

LINE OF SILL FLASHING BELOW

LINE OF HEAD FLASHING ABOVE

PRE-FINISHED 8g WAFER-TEKSCREW WITH EPDM WASHER

METALCRAFT ESPAN™VERTICAL CLADDING

5mm

GAP

PRE-FINISHED FIXING BRACKET WITH PRE-FINISHED POP RIVET BEDDED IN SILICONEOR PRE-FINISHED 8g WAFER-TEK SCREW

LINE OF SILL FLASHING BELOW

20mm HORIZONTAL CAVITYBATTEN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet

- DEPENDING ON ACTUAL SITUATION, A SECONDARY FLASHINGMAY BE REQUIRED. REFER METALCRAFT ROOFING FOR MOREINFORMATION.

1 : 2

RECESSED WINDOW JAMB

09 / 212018

Page 11: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

PERMEABLE WALL UNDERLAY DRESSEDINTO OPENING WITH FLEXIBLE FLASHINGTAPE INSTALLED OVER WRAP TO CORNERSAT HEAD

TEMPORARY PACKER IF REQUIRED, REMOVEDAFTER FIXING

EXTRA PERMEABLE WALL UNDERLAYOVER WINDOW HEAD FLASHING, SHOWNDASHED

INTERNAL WALL LINING

METERBOX LINTEL FRAMING

METALCRAFT ESPAN™ VERTICALCLADDING

PRE-FINISHED HEAD FLASHING WITH 15° FALL

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

METER BOX

STOPENDS TO HEAD FLASHING

LINE OF JAMB FLASHING BEHIND5m

m G

AP

DR

IP E

DG

E TO

CLA

DD

ING

MIN

. 15m

m G

AP

PRE-FINISHED 'U' BRACKET FIXED TOMETERBOX BEFORE INSTALLATIONMETAL ANGLE TO BE CONTINUOUS

AROUND METER BOX.

STST OR GALV. FLAT HEAD NAIL FOR FLASHING

CAVITY CLOSER AS REQUIRED TO NZBC

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

MIN

.75m

m W

ITH

OU

T H

EM E

DG

E

MIN

.50m

m C

OVE

R

METALCRAFT ESPAN™ CLIP SYSTEM WITH12G x 35mm SCREWS

20mm HORIZONTAL CAVITY BATTEN

MIN

. 15m

m G

AP

ALTERNATIVE OPTION

5mm

GAP

MIN

. 75m

m W

ITH

OU

T H

EM E

DG

E

MIN

. 50m

m C

OVE

R

SEPERATE BETTEN AND CLADDINGAS REQUIRED WITH EPDM

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet 1 : 2

METERBOX HEAD

10 / 212018

Page 12: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

METALCRAFT ESPAN™ VERTICALCLADDING

PERMEABLE WALL UNDERLAY,SHOWN DASHED

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

MIN. 8mm PACKER

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD, SILL AND JAMB

COMPRESSIBLE FOAM SEAL. REFERTO MRM CODE OF PRACTICEVERSION 2.2 /2012 FORREQUIRMENT.

WALL FRAMING

INTERNAL WALL LINING

LINE OF JAMB FLASHING BEHIND

20mm HORIZONTAL CAVITY BATTEN

FLEXIBLE FLASHING TAPE OVER PERMEABLE WALLUNDERLAY FULL WIDTH/DEPTH SILL

METAL ANGLE TO BE CONTINUOUSAROUND METER BOX.

PRE-FINISHED SILL FLASHING

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER FORFIXING TOP OF ESPAN™ CLADDING

STOPENDS TO SILL FLASHING

PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW

METER BOX

STOPENDS TO WALL CLADDING

5mm GAP

5mm gap

ALTERNATIVE OPTION

MIN

.100

mm

MIN

.100

mm

SEPERATE BATTEN AND CLADDING ASREQUIRED WITH EPDM

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet

- DEPENDING ON ACTUAL SITUATION, A SECONDARY FLASHINGMAY BE REQUIRED. REFER METALCRAFT ROOFING FOR MOREINFORMATION.

1 : 2

METERBOX SILL

11 / 212018

Page 13: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

METALCRAFT ESPAN™ VERTICALCLADDING

PERMEABLE WALL UNDERLAY, SHOWNDASHED

METER BOX

TIMBER PACKER

20mm JAMB BATTEN

INTERNAL WALL LINING

LINE OF SILL FLASHING BELOW

PRE-FINISHED SELF DRILLING/TAPPINGSCREW WITH RUBBER WASHER

LINE OF HEAD FLASHING ABOVE

PRE-FINISHED JAMB FLASHING FIXED TOMETERBOX BEFORE INSTALLATION

METAL ANGLE TO BE CONTINUOUSAROUND METER BOX.

AIRSEAL ON BACKING ROD TO RUNCONTINUOUSLY AROUND HEAD,SILL AND JAMB

FLEXIBLE FLASHING TAPE OVERPERMEABLE WALL UNDERLAY FOR FULLWIDTH/DEPTH SILL

LINE OF HEAD FLASHING ABOVE

STST OR GALV. FLAT HEAD NAIL FORFLASHING

PRE-FINISHED POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEKSCREW

20mm HORIZONTAL CAVITY BATTEN

5mm

GAP

PRE-FINISHED POP RIVET BEDDEDIN SILICONE OR PRE-FINISHED 8gWAFER-TEK SCREW

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet 1 : 2

METERBOX JAMB

12 / 212018

Page 14: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

METALCRAFT ESPAN™VERTICAL CLADDING

PRE-FINISHED 8g WAFER-TEKSCREW WITH EPDM WASHER

20mm HORIZONTAL CAVITYBATTEN

PRE-FINISHED INTERNALCORNER FLASHING

INTERNAL WALL LINING

PERMEABLE WALLUNDERLAY, SHOWN DASHED

WALL FRAMING

POP RIVET BEDDED IN SILICONE OR PRE-FINISHED 8g WAFER-TEK SCREW

PRE-FINISHED SECONDARYFLASHING

SEPERATE BATTEN ANDCLADDING WITH DPC ASREQUIRED

5mm GAP

5mm

GAP

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet 1 : 2

INTERNAL CORNER

13 / 212018

Page 15: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

20mm HORIZONTAL CAVITYBATTEN

METALCRAFT ESPAN™VERTICAL CLADDING

INTERNAL WALL LINING

PRE-FINISHED 8g WAFER-TEK SCREWWITH EPDM WASHER

WALL FRAMING

PRE-FINISHED EXTERNALCORNER FLASHING

PERMEABLE WALL UNDERLAY, SHOWNDASHED

PRE-FINISHEDSECONDARY FLASHING

POP RIVET BEDDED INSILICONE OR PRE-FINISHED 8g WAFER-TEKSCREW

SEPERATE BATTEN ANDCLADDING WITH DPC ASREQUIRED

5mm

GAP

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet 1 : 2

EXTERNAL CORNER

14 / 212018

Page 16: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

PERMEABLE WALLUNDERLAY, SHOWNDASHED

METALCRAFT ESPAN™VERTICAL CLADDING

PRE-FINISHED FLAT HEADWAFER-TEK SCREW WITHEPDM WASHER

INTERNAL WALL LINING

SEPARATE BATTEN ANDFLASHING AS REQUIRED WITHDPC

WALL FRAMING

PRE-FINISHED SOAKERFLASHING TO LINE UP WITHWINDOW JAMB ABOVE

20mm HORIZONTAL CAVITYBATTEN

SOAKER FLASHING ONLY REQUIRED TOLINE UP WITH WINDOW JAMB ABOVE.REFER TO MRM CODE OF PRACTICEVERSION 2.2 /2012 FOR REQUIRMENT.

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet 1 : 2

SOAKER FLASHING

15 / 212018

Page 17: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

METALCRAFT ESPAN™ VERTICALCLADDING

PRE FINISHED SCREWWITH RUBBERWASHER

20mm HORIZONTAL CAVITYBATTEN

FIBRE CEMENT BOARDBY OTHERS

PRE FINISHEDALUMINIUM FLASHING

PERMEABLE WALLUNDERLAY, SHOWNDASHED

INTERNAL WALL LINING

SEPARATE BATTEN AND FLASHING ASREQUIRED WITH DPC

5mm

GAP

MIN. 50mm

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet 1 : 2

CHANGE IN CLADDING

16 / 212018

Page 18: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

METALCRAFT ESPAN™ VERTICALCLADDING

WALL FRAMING

PRE FINISHED SCREWWITH RUBBERWASHER

CONCRETE WALL BYOTHERS

CONTINUOUS AIR SEAL ONBACKING ROD

DPC

PRE FINISHED ALUMINIUMFLASHING

20mm HORIZONTAL CAVITYBATTEN

PRE-FINISHED POP RIVETBEDDED IN SILICONE

PERMEABLE WALLUNDERLAY, SHOWNDASHED

SEPARATE BATTEN ANDFLASHING AS REQUIREDWITH DPC

INTERNAL WALLLINING

PRE-FINISHEDSECONDARY FLASHING

Mastic bead

5mm

GAP

ALTERNATIVE OPTION

Rawlplug

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet 1 : 2

CLADDING ABUTMENT

17 / 212018

Page 19: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

PERMEABLE WALL UNDERLAY, SHOWNDASHED

INTERNAL WALL LINING

WALL FRAMING

METALCRAFT ESPAN™VERTICAL CLADDING

PRE-FINISHED NON-PERFORATEDCLOSURE FLASHING WITH 10° FALLPRE-PRIMED SKIRTING

CONCRETE SLAB

MIN

. 50m

m L

AP

VEN

TILA

TIO

N G

AP

3-5m

m

DR

IP E

DG

E TO

CLA

DD

ING

MIN

. 15m

m G

AP

METALCRAFT ESPAN™ CLIP SYSTEMWITH 12G x 35mm SCREWS

STST OR GALV. FLAT HEAD NAIL FORFLASHING

CAVITY CLOSER AS REQUIRED TONZBC

20mm HORIZONTAL CAVITY BATTEN

SEPERATE BATTEN AND CLADDING ASREQUIRED WITH EPDM

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet 1 : 2

BOTTOM OF CLADDING (FLUSH)

18 / 212018

Page 20: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

PERMEABLE WALL UNDERLAY OVERFLASHING, SHOWN DASHED

INTERNAL WALL LINING

WALL FRAMING

METALCRAFT ESPAN™ VERTICALCLADDING

STST OR GALV. FLAT HEAD NAIL FORFLASHING

PRE-PRIMED SKIRTING

CONCRETE SLAB

METALCRAFT ESPAN™ CLIP SYSTEMWITH 12G x 35mm SCREW

PRE-FINISHED NON-PERFORATEDCLOSURE FLASHING WITH 10° FALL

CAVITY CLOSER AS REQUIRED TONZBC

20mm HORIZONTAL CAVITY BATTEN

SEPERATE BATTEN AND CLADDING ASREQUIRED WITH DPC

3-5m

m V

ENTI

ALTI

ON

GAP

MIN

. 50m

m L

APM

IN. 7

5mm

CO

VER

ALTERNATIVE OPTION

6mm GAPM

IN. 5

0mm

LAP

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet 1 : 2

BOTTOM OF CLADDING (RECESSED)

19 / 212018

Page 21: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet

3D WINDOW FLASHINGS

20 / 212018

RECESSED WINDOW FLASHINGS

HEAD FLASHING

JAMB FLASHING

SILL FLASHING

ALUMINIUMWINDOWJOINERY

METALCRAFTESPAN™ VERTICALCLADDING

Page 22: Espan 340™ / 470™ · 2018. 3. 1. · min.10mm cover suggest min. 50mm dimension to suit permeable wall underlay, shown dashed double glazing window joinery line of window sill

LIP OF DISCHARGE AT LOWEST POINTOF ROOF

DOWNPIPE

OVERFLOW BELOW OPENING LEVEL, 1.5 xCROSS-SECTION AREA OF DOWNPIPE

METALCRAFT ESPAN™ VERTICALCLADDING

EITHER SIDE

50 mm MIN OPENING200 mm MIN

OPE

NIN

G

75 m

m M

IN

Reference

DISCLAIMER:All details are to be used for indicative purposes only and the designer should consult both the MRMcode of pratice version 2.2 /2012, E2 and all other relevant building codesDetails of the supporting mechanisms are indicative only. Compliance of the supporting mechanismsis the responsibility of the designer. Construction detail can vary for wall cladding. The underlay isdetailed as a single line for simplicity and is indicative only. Building paper type and method ofinstallation should comply with underlay manufacturers recommendations and NZBC regulations.

RESIDENTIAL VERTICAL CLADDING

RVEP

Espan 340 / 470™

- CAVITY SYSTEM FOR VERTICAL CLADDING : 20mm NOMINAL THICK(VERTICALLY DRAINING) HORIZONTAL CAVITY SYSTEM WITH BATTENSAS APPLICABLE TO SUPPORT CLADDINGS & FLASHINGS TO NZBC.

ScaleDate Sheet

3D RAINWATER HEAD

21 / 212018