ESC motors are suitable for driving various kinds of
machines or equiment. The output ratings are from
0.18KW to 355kW. The frame sizes are from 80 to 355.
ESC the motors have cast iron stator frame, endshields
and terminal boxes. The feet integrally cast into the stator
frame. The terminal box is mounted on the top as standard.
All motors comply with the requirements for European CE
marking.
Standard ESC series motors with the terminal box is
located on the top.The terminal box can be rotated through
4 positions, 90 part.
All motors are designed for high efficiency and low
temperature giving a long economical service life.
• Motors with terminal boxes on the right side or on the left
side are available.
• Motors from frame sizes 63 to 160 with aluminium stator
frames, terminal boxes and cast iron endshields are also
available.
Coolingandventilation
Enclosure
Voltageandfrequency
Connection
Noise
Vibration
The standard cooling method is totally Enclosed Fan Cooled
(TEFC) in accordance with code IC411 of IEC60034-6.
Standard motors in sizes 80-315 are equipped with radial-flow
plastic fans.
Standard motors in size 355 are equipped with radial-flow
aluminium fans.
The standard degree ofprotection is IP55.
The IP55 enclosure means complete hoseproof and dustproof
protection.
Ahigher degree ofprotection is available.
Standard voltages are 380V 50Hz or 425V 50Hz, but can be
wound for any single voltage in the range 200-600V at a
frequency 50 or 60 Hz.
The motors will operate satisfactorily with voltage variations of
±10% from the rated voltage.
Direct - on line starting can be used on all frame sizes. Motors up
to and including 2.2kW are star connected and cannot be started
with Star/Delt started.Motors above 2.2kWare delta staring.
The permitted noise levels of electrical machines are fixed in
IEC60034 - 9 (EN60034-9). The noise level of ESC motors is well
below this limit value.
Fordetails, please refer to the performance data tables.
Standard motors are designed to vibration class N (normal)
vibration class R (reduced) and vibration class S (special) are
available on request.
Stringent quality procedures are observed from first design to
finished products in accordance with ISO9001 documented
quality systems.Our factories have been assessed to meet these requirements, afurther assurance that only the highest possible standards ofquality are accepted.
Qualityassurance
Specification
General specification
ESC motors are built to comply with the requirements of the following international standards and regulation
1. International Electrotechnical commission - IEC 60034 and IEC 60072.
2. British Standards - BS5000 and BS 4999.
3. Australian Standards -AS 1359.
4. The requirements of European EC marking. Low voltage Directive 73/23 (1973). Modified by Directive 93/68 (1993) and the
EMC - Directive 89/336. These ESC motors are designed for use with other machinery, and they should only be used if the
complete machinery is in conformity with the provisions of the Directive of safety of machinery (89/93/EEC).
5. CEMEP agreement-all motors with standard rating include in this catalogue comply with efficiency class EFF2 and bear the
corresponding label on the rating plate. For efficiency data at 50%, 75% and full load, please refer to the performance data tables.
Motors comply with efficiency class EFF1 are available on request.
2
Standards IEC CENELEC BS
Methods of determining losses and efficiency
Degrees of protection
Methods of cooling
Mounting arrangements
Terminal markings and direction of rotation
Noise limits
Starting performance
Mechanical vibration
Standard voltages
Dimensions and output ratings
Mounting dimensions and relationshipframesizes-output ratings
Shaft dimensions
EN 60034-1
HD 53 2
EN60034-5
EN60034-6
EN60034-7
HD 53 8S4
EN60034-9
EN60034-12
EN60034-14
HD 472 S1
HD 231
HD 231
4999-14999-69
4999-34
4999-20
4999-21
4999-22
4999-3
4999-51
4999-112
4999-50
4999-1051-110
4999-10
Classification of environmental conditions
Insulation material
60034-1
60034-2
60034-5
60034-6
60034-7
60034-8
60034-9
60034-12
60034-14
60038
60072
60072
60072
600721-2-1
60085
General requirements for electrical machines
Standards and regulations
Foot mounting
3
Connection diagrams three phase motors with cage rotor
Standards and regulations
Against solar radiation
Degree of protection
IP standards explanation
Shaft
Finish
High solar radiation will result in undue temperature rise. In
these circumstances motors should be screened from solar
radiation by placement of adequate sunshades which do not
inhibit air flow.
Standard levels of enclosure protection for all ESC frame
sizes for both motor and terminal box is IP55, with IP56, IP65
and IP66 available on request. Enclosure designations
comply with IEC or AS60529. The enclosure protection
required will depend upon the environmental and operational
conditions within which the motor is to operate.
First characteristic numeral Degree of protection of persons
against approach to live parts or contact with live or moving
parts (other than smooth rotating shafts and the like) inside
the enclosure, and degree of protection of equipment within
the enclosure against the ingress of solid foreign bodies.
4 = Protected against solid object greater than 1.0 mm:
Wires or strips of thickness greater than 1.0 mm,
solid objects exceeding 1.0 mm
5 =Dust protected: Ingress of dust is not totally
prevented but it does not enter in sufficient
quantity to interfere with satisfactory operation
of the equipment.
6 = Dust tight: No ingress of dust.
Second characteristic numeral
4 = Protected against splashing water: Water
splashed against the enclosure from any
direction shall have no harmful effect.
5 = Protected against water jets: Water projected
by a nozzle against the enclosure from any
direction shall have no harmful effect.
6 = Protected against heavy seas: Water from
heavy seas or water projected in powerful jets
(larger nozzle and higher pressure than
second numeral 5) shall not enter the enclosure
in harmful quantities.
ESC motors have standard shaft extension lengths and are
provided with standard key, and drilled and tapped hole.
Non standard shaft extensions are available upon special
order, with shaft design outlined on a detailed drawing.
Shaft extension run out, concentricity and perpendicularity to
face of standard flange mount motors, comply with normal
grade tolerance as specified in IEC 60072-1 and AS1359.
Precision grade tolerance is available upon special order.
Standard ESC motor color is RAL 7044. Other colors are also
available. All castings and steel parts are provided with a
prime coat of rust-resistant paint.
The finishing coat of enamel paint is sufficient for normal
conditions, however special paint systems can be provided
to accommodate stringent requirements for motors in
corrosive environments. Special coatings are needed to
resist such substances as acid, salt water and extreme
climatic conditions.International protection rating prefix (IEC 60034 - 5)
First numeral
Second numeral
Electrical design
As standard, ESC motors have the following design and
operating parameters. Performance data is based on this
standard. Any deviation should be examined and
performance values altered in accordance with the
information provided in this section.
Three phase, 380V, 50Hz
Ambient cooling air temperature, 40°C
Altitude - 1000m Duty cycle S1 (continuous)
Rotatio - Clockwise viewed from drive end
Connection - 230 volt Delta/380 volt Star (3kW and below)
- 380 volt Delta/660 volt Star (4kW and above)
Standard ESC motors are designed for a power supply of
three phase 380V, 50Hz. Motors can be manufactured for any
supply between 100V and 1100V and frequencies other than
50Hz.
Standard ESC motors wound for a certain voltage at 50Hz can
Voltage and frequency
4
I P 5 5
1 2
General specification
Temperature and altitude
Rotation
Rated power specified in the performance data tables apply
for standard ambient conditions of 40°C at 1000m above sea
level. Where temperature or altitude differ from the
standard, multiplication factors in the table below should
be used.
Effective Power required = 15kW
Air temperature = 50°C (factor 0.93)
Altitude = 2500 metres (factor 0.91)
The appropriate motor is one with a rated power above the
required, being 18.5kW.
For clockwise rotation, viewed from drive end, standard
three phase ESC motor terminal markings coincide with
the sequence of the phase line conductors.
For counter clockwise rotation, viewed from drive end, two of
the line conductors have to be reversed. This is made clear
in the accompanying table.
Example 1
Example 2
Rated power = 11kW
Air temperature = 50°C (factor 0.93)
Altitude = 1500 metres (factor 0.98)
Effective Power = 11 x 0.93 x 0.98 = 10.0kW
5
Rated power
required=
15= 17.7kW
0.93 x 0.91
also operate at other voltages at 50Hz and 60Hz without
modification, subject to the changes in their data .
Not applicable for motors with F class temperature rise.
* Note: This table is not applicable for hazardous area motors
1) N = Full load current TN = Full load torque
I /I =Locked rotor current/ full load current
T /T =Locked rotor torque/ full load torque
T /T = Breakdown torque/full load torque
Standard torque values for alternative supplies are
obtainable only with special windings. For these
purpose-built motors the performance data is the same
as for 380V motors except for the currents which are
calculated with the accompanying formula:
Where:
I = Current
I = Full load current at 380 volt
U = Design voltage
*
L N
L N
B N
X
N
X
IX
=
380 x
UX
IN
Motor
wound
for 50Hz
at rated
voltage -
Connected
to
Data in percentage of values at 50Hz and
rated voltage
Output r/min I /IN N
IL
TN
T /TL N
T /TB N
380V
400V
415V
525V
400V
380V
400V
415V
440V
460V
380V
415V
400V
415V
440V
460V
480V
380V
400V
440V
415V
440V
460V
480V
550V
525V
550V
575V
600V
50Hz
60Hz
60Hz
60Hz
60Hz
60Hz
50Hz
50Hz
60Hz
60Hz
60Hz
60Hz
60Hz
50Hz*
50Hz
50Hz
60Hz
60Hz
60Hz
60Hz
50Hz
60Hz
60Hz
60Hz
60Hz
100
100
105
110
115
120
100
100
100
104
110
115
120
100
100
100
100
105
110
115
100
100
105
110
115
100
120
120
120
120
120
100
100
120
120
120
120
120
100
100
100
120
120
120
120
100
120
120
120
120
95
98
98
98
100
100
105
96
98
98
98
100
100
109
104
94
98
98
98
100
95
98
98
98
100
110
83
90
95
100
105
91
108
83
89
95
100
105
84
93
112
83
90
95
100
110
83
90
95
100
100
83
87
91
96
100
100
100
83
86
91
96
100
100
100
100
83
87
91
96
100
83
87
91
96
110
70
80
85
95
100
90
108
70
75
85
93
100
84
93
112
70
80
85
95
110
70
80
85
95
110
85
90
93
98
103
90
108
85
88
93
98
103
84
93
112
85
90
94
98
110
85
90
94
98
Power=
Powerx
Factorx
Effective Rated Temperature Altitude
Factor
Ambient
temperature
Temperature
factor
Altitude above
sea level Altitude factor
30°C 1.06 1000m 1.00
35°C 1.03 1500m 0.98
40°C 1.00 2000m 0.94
45°C 0.97 2500m 0.91
50°C 0.93 3000m 0.87
55°C 0.88 3500m 0.82
60°C 0.82 4000m 0.77
General specification
DutyESC motors are supplied suitable for S1 operation (continuous operation under rated load). When the motor is to operate
under any other type of duty the following information should be supplied to determine the correct motor size:
• Type and frequency of switching cycles as per duty factors S3 to S7 and duty cycle factor.
• Load torque variation during motor acceleration and braking (in graphical form).
• Moment of inertia of the load on the motor shaft.
• Type of braking (eg mechanical, electrical through phase reversal or DC injection).
Permissible output
Connection
Internal connections, voltages andVF drive selection
Apply the factors in the accompanying table to the output
rating for motors with duty cycles that are not continuous.
For other duties (S4, S5, S6 and S7) contact ESC for
appropriate duty cycle factors.
A motor’s rated voltage must agree with the power supply
line-to-line voltage. Care must therefore be taken to ensure
the correct connection to the motor terminals.
Standard terminal connections for motors 3kW and below is
220V delta / 380V star. These motors are designed for 380V
Direct On Line (D.O.L.) starting, when connected in the star
configuration. They are also suitable for operation with 220V
three phase variable frequency drives. when connected in
the delta configuration. Standard terminal connections for
motors 4kW and above is 380V delta / 660V star. These
motors are designed for 380V Direct On Line (D.O.L.)
starting, when connected in the delta configuration. They
are also suitable for operation with 380V three phase
variable frequency drives. Alternatively they can be
operated D.O.L. in the star configuration from a 660V supply
or with a 660V variable frequency drive.
In this case the drive must be supplied with an output reactor
to protect the winding insulation. These size motors are also
suitable for 380V tar-delta starting as described below.
Motor connected for D.O.L. starting with bridges in place for
star connection ( 3kW and below)
Poles
Duty cycle factor
For frames
80 to 132
For frames
160 to 250
For frames
280 to 355
Short-time duty, S2
30 min 2 1.05 1.20 1.20
4 to 8 1.10 1.20 1.20
60 min 2 to 8 1.00 1.10 1.10
Intermittent duty, S3
15% 2 1.15 1.45 1.40
4 to 8 1.40 1.40 1.40
25% 2 1.10 1.30 1.30
4 to 8 1.30 1.25 1.30
40% 2 1.10 1.10 1.20
4 to 8 1.20 1.08 1.20
60% 2 1.05 1.07 1.10
4 to 8 1.10 1.05 1.10
380 Volt
6
Symbol
Type
S1 Operating time Continuous
S2 Operating time 0.5; 1; 3; 5; 10; 30; 60; 90 mins
S3 S6 Period of one cycle 10 mins
S4 S5 S7 S8 Switching rate 60, 90, 120, 240, 600 c/h
S3 S4 S5 S6 Relative on period 15%; 25%; 40%, 60%
S4 S5 S7 S8 moment of inertia factor F1 1.2; 1.6; 2.5; 4
Design data
Preferred value
General specification
Motor connected for D.O.L. starting with bridges in place for
delta connection (4kW and above).
All of the following starter options are available through
ESC Drives division, and are best supplied together with the
motor.
When an electric motor is started by direct connection
to the power supply (D.O.L.), it draws a high current,
called the ‘starting current’, which is approximately equal
in magnitude to the locked rotor current I . As listed in
the performance data, locked rotor current can be up
to 8 times the rated current I of the motor. In circumstances
where the motor starts under no load or where high starting
toque is not required, it is preferable to reduce the starting
current by one of the following means.
ESC motors 3.0kW and above are suitable for thestar-delta starting method. Through the use of astar-delta starter, the motor terminals are connected in thestar configuration during starting, and reconnected to thedelta configuration when running.
The benefits of this starting method are a significantly lower
starting current, to a value about 1/3 of the D.O.L. starting
current, and a corresponding starting torque also reduced
to about 1/3 of its D.O.L. value. It should be noted that a
second current surge occurs on changeover to the delta
connection. The level of this surge will depend on the speed
the motor has reached at the moment of change over.
Variable Voltage Variable Frequency drives are primarily
recognized for their ability to manipulate power from a
constant 3 phase 50/60Hz supply converting it to variable
voltage and variable frequency power. This enables the
speed of the motor to be matched to its load in a
flexible and energy efficient manner. The only way of
producing starting torque equal to full load torque with
full load current is by using VVVF drives. The functionally
flexible VVVF drive is also commonly used to reduce
energy consumption on fans, pumps and compressors and
offers a simple andrepeatable method of changing speeds
or flow rates.
Capacitive voltages in the rotor can be generated due to an
effect caused by harmonics in the waveform causing voltage
discharge to earth through the bearings. This discharge
results in etching of the bearing running surfaces. This effect
is known as Electrical Discharge Machining (EDM). It can be
control with the fitment of appropriate filters to the drive.
To futher reduce the of EDM, an insulated non drive bearing
can be used. ESC recommends the use of insulated
bearings for all motors 315 frame and above.
Starting
EDM Concerns
D.O.L Starters
Star - delta starting
VVVF Drives
L
N
380 Volt
110
100
90
80
70
60
50
40
30
20
10
0
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75
Torq
ue (
% o
f ra
ted)
Frequency (Hz)
7
General specification
8
Insulation
Thermal protection
Speed at partial loads
Torque characteristics
The insulation system is Class F (150K) and the motors are
designed to operate with Class B (80K).
This ensures long life and reliability with the ability to
withstand ambient temperatures as high as 54 C or up to
15% overload in adverse electrical supply situations.
Non-Standard ESC will provide a safety margin of 45K and
can be safely operated at elevated ambient temperatures.
Due to their conservative design many sizes in the ESC
range of motors have temperature rises considerably
less than 80K and therefore provide even greater
safety margins.
Motors can be protected against excessive
temperature rise by inserting, at various positions within
the windings, thermal probes which can either give a
warning signal or cut off the supply to the motor in the event
of a temperature abnormality.
The units fitted to ESC motors, frame sizes 160 and above,
are PTC thermistors. These thermovariable resistors, with
positive temperature co-efficient, are fitted one per phase,
series connected and are terminated in a terminal
strip located in the terminal box. Trip temperature is
160°C (180°C for ESC series). Additional 130°C
thermistors can be fitted as an option for alarm connection.
The relationship between motor speed and degree of
loading on an ESC motor is approximately linear up
to the rated load. This is expressed graphically in
the accompanying drawing.
Where:
n = full load speed
n = synchronous speed
P/P = partial load factor
Current at partial loads can be calculated using the
following formula:
Where:
I = partial load current (amps)
Pout = partial load (kW)
U = rated voltage
cos = partial load power factor
= partial load efficiency (%)
Typical characteristics of torque behaviour relative to
speed are shown in the torque speed curve example
below.
Where:
T = full load torque
T = locked rotor torque
T = pull-up torque
T = break down torque
n = full load speed
n = synchronous speed
ESC motors all exceed the minimum starting torque
requirements for Design N (Normal torque) as specified
in IEC60034-12, and in most cases meet the
requirements of Design H (High torque). Rated torque
can be calculated with the following formula:
Where:
T = full load torque (Nm)
P = full load output power (kW)
n = full load speed (r/min)
0
N
S
N
X
X
N
X
X
N
L
U
B
N
S
N
N
N
Current at partial loads
φ
η
Insulation class
B F H
Max. permissible winding temp. (°C) 130 155 180
Less ambient temp. (°C) -40 -40 -40
Less hotspot allowance (K) -10 -10 -15
Equals max. permissible temp.rise (K) 80 150 125
Less max. design temp. rise (K) -80 -80 -80
Equals min. safety margin (K) - 25 45
I =x
Poutx x 105
3 x U X XN XcosφX η
pN
TN
=9950 x
nN
Load Torque
General specification
9
3000r/min = 2 poles
2 Pole - 3000 rpm synchronous speed 50Hz
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
280
315
5.5
11
75
110
100 75 50
Efficiency %
at % full loadFull load I , 50HzN
380V 400V 415V
Current
(A) (A) (A)
Locked
rotor
I /IL N
Moment
of inertia
(kg m )
J=1/4 GD
x
2
2
Nosie
level
at1meter
dB(A)
Net
weight
(kg)
Locked
rotor
T /TL N
Pull
up
T /TU N
Break
down
T /TB N
Torque
Full
load
T
(Nm)N
Output
(kW)
Full
lock
speed
(rpm)
100 75 50
power factor, cos
at % full load
φFrame
Size
High Output Design*
* The motor is increased output (kW) in a reduced frame size electric motor.
220
250
2840
2840
2850
2850
2880
2880
2900
2900
2930
2930
2930
2940
2950
2950
2970
2970
2970
2970
2980
2980
2880
2910
2970
2980
2980
2980
2980
2980
2980
2980
1.80
2.60
3.40
4.80
6.30
8.30
11.1
14.9
21.1
28.6
34.6
41.0
55.4
67.9
82.1
99.6
134.8
159.5
194.6
233
282.1
347.7
11.1
21.4
135.1
194.7
478
537
379
429
1.70
2.50
3.20
4.60
6.00
7.90
185
128.4
20.4
10.5
270
330.1
221.4
184.9
151.5
128.1
10.5
14.2
20.1
94.6
78.0
64.5
52.6
38.9
32.9
27.2
510
457
361
408
1.67
2.40
3.10
4.40
5.80
7.60
10.2
13.5
19.4
26.2
31.8
37.6
50.7
62.2
75.3
91.3
123.5
146.1
178.2
213.4
258.4
318.4
437
491
10.2
19.7
123.8
178.3
349
393
6.5
6.5
6.2
7.7
5.5
5.6
6.1
6.1
6.5
6.5
6.9
6.9
6.7
6.7
6.7
6.7
6.6
6.6
6.7
6.7
6.8
6.8
6.5
6.5
6.6
6.8
5.46
6.69
5.42
5.74
75.5
76.1
79.5
81.7
83.1
83.5
85.9
87.2
88.7
89.5
90.2
90.6
91.5
92.0
92.5
93.2
93.9
94.2
94.4
94.6
94.7
95.0
95.6
95.7
94.3
85.7
88.4
93.7
95.5
95.6
74.8
75.8
78.8
80.3
82.6
84.1
85.7
86.9
87.2
89.5
93.9
93.4
88.0
85.4
89.3
90.1
90.1
91.6
90.9
92.9
93.2
93.9
93.7
94.4
94.2
94.5
94.9
95.1
95
94.9
72.3
73.1
76.7
78.6
81.3
83.3
84.4
84.7
86.1
88.6
88.4
89.4
87.0
88.1
88.4
92.9
84.6
83.8
51.9
94.0
93.0
93.6
93.0
93.0
92.3
92.5
91.2
90.1
94.1
93.0
0.83
0.84
0.85
0.85
0.87
0.88
0.88
0.88
0.89
0.89
0.90
0.90
0.90
0.90
0.90
0.88
0.88
0.90
0.91
0.90
0.90
0.91
0.91
0.91
0.91
0.92
0.92
0.93
0.92
0.92
0.79
0.81
0.81
0.81
0.83
0.84
0.85
0.84
0.85
0.80
0.87
0.87
0.88
0.92
0.93
0.91
0.91
0.90
0.89
0.88
0.89
0.87
0.90
0.89
0.87
0.89
0.87
0.87
0.91
0.91
0.66
0.68
0.70
0.71
0.73
0.78
0.78
0.79
0.81
0.83
0.81
0.79
0.83
0.90
0.82
0.82
0.84
0.83
0.85
0.81
0.82
0.86
0.83
0.86
0.87
0.89
0.88
0.90
0.89
0.88
2.5
3.7
5.0
7.4
10.0
13.3
18.1
24.5
35.8
97.2
71.4
60.4
48.8
13.3
36.2
241
354
1010
641
513
423
353
290
241
177
145
119.8
705
897
802
2.7
2.2
2.3
2
2.3
2.3
2.5
2.7
2.7
2.6
2.3
2.5
2.6
2.6
2.5
2.6
2.5
2.4
2.4
2.5
2.4
2.4
2.0
2.1
1.9
1.9
2.01
1.61
1.48
1.65
1.9
2.4
2.1
2.0
1.8
2.0
2.1
2.3
2.5
2.2
2.0
2.3
2.2
2.1
2.0
2.1
2.2
2.0
2.2
1.8
1.9
1.9
1.7
1.9
1.7
1.7
1.6
1.5
1.31
1.40
2.6
2.6
2.9
2.9
2.9
2.9
2.6
2.8
2.9
2.4
3.2
3.2
2.5
2.9
2.8
2.8
2.7
2.6
2.6
2.8
2.7
2.7
2.5
2.5
2.4
2.4
2.76
2.29
2.34
2.44
67
67
72
72
76
77
78
83
94
96
80
80
86
86
89
89
92
92
92
93
94
94
96
96
99
99
103
103
103
103
42
72
440
546
13
15
20
23
30
40
54
60
99
110
127
167
220
242
281
373
477
516
792
828
932
1044
1798
1834
1490
1638
0.0008
0.0009
0.0012
0.0014
0.0039
0.0055
0.0109
0.013
0.038
0.045
0.055
0.076
0.124
0.139
0.233
0.312
0.597
0.675
1.18
1.55
1.76
4.1
0.007
0.028
0.412
0.86
2.02
3.91
3.21
3.56
80M1
80M2
90S
90L
100L
112M1
132S1
132S2
160M1
160M2
160L
180M
200L1
200L2
225M
250M1
280S
280M1
315S
315M
112M2
132M
250M2
280M2
315L1
315L2
355L1
355L2
355M1
355M2
Performance data
10
4 Pole - 1500 rpm synchronous speed 50Hz
High Output Design*
* The motor is increased output (kW) in a reduced frame size electric motor.
1500r/min = 4 poles
11
75
315
355
110
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
90
132
160
110
75
200
250
220
280
132M2
250M2
280M2
80M1
80M2
90S
90L
100L1
100L2
112M
132S
132M1
160M
160L
180M
180L
200L
225S
225M
250M1
280M1
280S
315M
315L1
315L2
355M2
315S
355M1
355L2
355L
355L1
1480
1480
1480
1490
1490
1490
1440
1480
1480
1390
1390
1400
1400
1420
1420
1440
1440
1440
1460
1460
1470
1470
1470
1480
1480
1480
1480
1480
1480
1490
1490
240
287
358
554
620
22.6
138.4
201
1.60
2.10
2.90
3.80
5.10
6.80
8.80
11.7
15.6
22.5
30.3
36.2
42.9
57.5
69.7
84.5
103
165
200.5
138.1
388
440
492
228
272.7
340.1
420
521
592
21.5
131.5
191
1.50
2.00
2.80
3.60
4.80
6.50
8.40
11.1
14.8
21.4
28.8
34.4
40.8
54.6
66.2
80.3
97.9
156.8
190.5
131.2
372
471
219.8
262.8
327.8
506
567
20.7
126.7
184
1.40
1.90
2.70
3.50
4.70
6.20
8.10
10.7
14.3
20.6
27.7
33.1
39.3
52.7
63.8
77.4
94.3
151.1
183.6
126.5
356
403
450
6.8
6.6
6.4
6.2
6.5
6.8
5.5
5.6
5.4
5.2
6.0
6.1
6.5
6.8
6.5
6.9
6.8
6.4
6.9
6.8
6.5
6.3
6.4
6.9
6.5
6.8
6.05
6.44
6.21
6.18
6.17
95.0
95.2
95.4
95.6
95.7
95.8
88.4
93.6
94.5
71.4
73.5
76.2
78.7
81.0
82.7
84.5
85.7
87.1
88.6
89.5
90.2
90.7
92.1
92.7
93.0
93.3
94.1
94.7
93.8
95.6
95.7
70.9
73.2
75.9
78.3
80.7
82.3
84.0
85.2
86.5
87.6
88.5
89.6
90.2
91.5
92.1
92.4
92.6
93.8
93.9
93.3
94.3
94.4
94.6
94.8
95.6
95.7
87.9
93.4
94.0
94.8
95.6
93.0
93.3
93.6
93.3
94.4
94.6
86.5
91.4
91.9
68.9
71.4
74.6
76.6
79.6
80.9
81.9
83.9
84.5
86.5
87.2
88.1
88.0
88.8
90.3
90.3
90.4
91.6
91.9
91.6
93.8
94.4
0.88
0.89
0.89
0.90
0.90
0.91
0.84
0.88
0.89
0.75
0.76
0.77
0.78
0.81
0.82
0.82
0.83
0.84
0.84
0.85
0.86
0.86
0.86
0.87
0.87
0.87
0.88
0.88
0.88
0.90
0.90
0.88
0.86
0.87
0.89
0.87
0.88
0.79
0.87
0.87
0.67
0.66
0.66
0.70
0.71
0.76
0.75
0.77
0.79
0.82
0.82
0.82
0.83
0.83
0.85
0.84
0.84
0.87
0.88
0.87
0.86
0.87
0.83
0.81
0.78
0.87
0.85
0.86
0.71
0.82
0.82
0.55
0.55
0.52
0.58
0.58
0.64
0.66
0.68
0.70
0.76
0.75
0.72
0.74
0.78
0.76
0.78
0.78
0.81
0.86
0.83
0.79
0.85
73
483.9
709.8
3.8
5.2
7.5
10.2
14.8
20.2
26.5
36.5
49.8
72.0
98.2
120.2
143
195
238.9
290.5
851.8
355.1
580.7
709.8
483.9
2275
1032
1290
1603
2020
1410
1795
2.3
2.6
2.2
2.1
2.2
2.3
2.1
2.2
2.2
2.2
2.4
2.3
2.3
2.3
2.3
2.4
2.3
2.3
2.3
2.3
2.4
2.2
2.3
2.2
2.2
1.9
2.1
1.93
1.94
2.17
2.01
75
427
830
2083
13
15
20
24
29
32
42
57
69
918
107
129
162
172
224
277
302
383
548
850
527
1018
1122
1650
1804
1592
1758
1.7
1.6
1.8
1.8
1.6
1.8
1.8
1.9
1.8
2.0
1.9
2.0
2.1
2.0
2.1
1.9
2.0
2.1
1.9
2.1
2.0
1.9
1.8
1.6
1.8
1.9
1.7
1.8
1.8
1.7
1.6
3.2
2.8
3.0
2.7
2.6
2.3
2.4
2.4
2.5
2.6
2.6
2.7
2.8
2.9
3.0
2.9
2.9
2.9
2.9
2.9
2.7
2.5
2.5
2.7
2.7
2.8
2.33
2.42
2.32
2.41
2.35
7.9
0.057
0.88
2.68
0.002
0.002
0.002
0.003
0.007
0.007
0.0095
0.0214
0.0296
0.0075
0.0092
0.139
0.158
0.262
0.406
0.469
0.66
1.46
1.12
3.29
3.79
4.49
5.67
6.66
3.11
5.28
6.17
58
58
61
61
64
64
65
71
71
75
75
76
76
79
81
90
97
97
101
101
101
75
86
93
81
83
86
86
93
101
101
100 75 50
Efficiency %
at % full loadFull load I , 50HzN
380V 400V 415V
Current
(A) (A) (A)
Locked
rotor
I /IL N
Moment
of inertia
(kg m )
J=1/4 GD
x
2
2
Nosie
level
at1meter
dB(A)
Net
weight
(kg)
Locked
rotor
T /TL N
Pull
up
T /TU N
Break
down
T /TB N
Torque
Full
load
T
(Nm)N
Output
(kW)
Full
lock
speed
(rpm)
100 75 50
power factor, cos
at % full load
φFrame
Size
Performance data
11
6 Pole - 1000 rpm synchronous speed 50Hz
1000 r/min = 6 poles
High Output Design*
* The motor is increased output (kW) in a reduced frame size electric motor.
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
75
90
55
75
110
132
160
185
200
250
220
280
890
890
910
910
920
940
960
960
960
970
970
970
970
970
980
980
980
985
990
990
990
990
990
990
990
990
990
990
990
1.30
1.80
2.3
3.20
4.10
5.60
7.20
9.70
12.8
17.1
24.5
31.6
38.5
44.7
59.3
70.1
86.0
140
105
142
170
206
244
291
448
335
361
395
501
1.20
1.70
2.20
3.00
3.90
5.30
7.00
9.20
12.2
16.2
23.3
30.0
36.6
42.5
56.3
66.6
81.7
99.8
134.9
161.5
195.7
231.8
133
275
342
317
376
425
477
1.20
1.60
2.10
2.90
3.80
5.10
6.80
8.90
11.7
15.7
22.4
28.9
35.3
40.9
54.3
64.2
78.7
96.1
130
155.7
188.6
223.4
267
330
409
128.2
306
365
460
4.4
4.5
4.1
4.6
5.0
5.2
5.6
6.2
6.5
5.6
5.8
5.7
6.7
6.6
6.8
6.2
6.1
6.7
6.5
6.2
6.0
5.8
5.8
7.13
7.09
6.59
6.94
5.90
6.32
62.5
65.0
69.1
72.0
76.0
79.1
81.3
82.3
84.7
86.6
87.6
89.0
90.2
90.2
91.5
92.2
92.5
92.9
94.4
93.9
94.5
94.6
95.4
95.5
95.6
93.6
95.4
95.5
95.6
61.4
64.7
68.7
71.6
76.6
78.6
80.8
81.9
84.3
86.1
87.1
88.4
90.0
89.8
91.0
91.9
92.2
92.5
93.6
93.5
94.2
94.3
95.0
96.2
95.1
93.0
95.0
95.0
95.1
55.2
63.0
65.6
69.5
73.1
76.5
77.8
79.5
82.0
83.6
85.2
86.3
87.4
87.6
88.1
89.3
89.4
90.4
91.7
91.6
92.3
92.3
93.1
94.1
92.9
91.6
93.1
92.8
92.9
0.70
0.72
0.72
0.73
0.75
0.76
0.76
0.76
0.77
0.77
0.78
0.81
0.81
0.83
0.84
0.86
0.86
0.86
0.86
0.86
0.86
0.87
0.87
0.88
0.89
0.87
0.88
0.88
0.89
0.63
0.62
0.65
0.66
0.73
0.67
0.67
0.67
0.68
0.74
0.76
0.77
0.78
0.80
0.82
0.81
0.83
0.86
0.84
0.84
0.85
0.87
0.87
0.85
0.86
0.83
0.88
0.85
0.86
0.50
0.53
0.56
0.52
0.56
0.59
0.54
0.56
0.55
0.68
0.67
0.63
0.69
0.71
0.76
0.75
0.76
0.81
0.80
0.77
0.82
0.81
0.83
0.81
0.82
0.77
0.84
0.81
0.82
0.002
0.003
0.003
0.004
0.007
0.014
0.029
0.036
0.045
0.088
0.116
0.207
0.315
0.36
0.547
0.834
3.21
1.39
1.65
4.11
4.28
5.45
6.12
8.85
9.55
9.13
10.05
10.3
10.8
82
54
54
57
57
61
65
69
69
69
73
73
73
76
76
76
78
80
80
85
85
85
85
92
92
92
92
92
92
15
16
21
23
29
37
52
59
72
98
121
164
208
217
287
355
456
502
786
884
964
1060
1554
1768
1902
630
1620
1796
1962
280M2
80M1
80M2
90S
90L
100L
112M
132S
132M1
132M2
160M
160L
180L
200L1
200L2
225M
250M
280S
280M1
315S
315M
315L1
315L2
355M1
355M3
355L2
355M2
355L1
355L
4.0
5.9
7.9
11.5
15.6
22.4
29.9
39.8
54.7
73.9
108
148
182
217
293
361
438
536
724
869
727
1062
1274
1544
1930
1785
2413
2122
2701
1.9
2.1
2.3
2.3
2.4
2.1
1.9
2.1
2.3
2.0
2.1
2.0
2.2
2.3
2.2
2.0
1.9
2.1
2.0
2.0
1.9
2.0
2.28
2.3
2.16
2.1
2.24
1.84
2.08
2.3
2.4
2.7
2.7
2.8
2.5
2.5
2.7
2.8
2.6
2.4
2.4
2.8
2.9
2.7
2.5
2.5
2.7
2.7
2.6
2.7
2.7
2.3
2.95
2.89
2.64
2.84
2.73
2.52
1.8
1.6
1.9
1.7
1.8
1.8
1.7
1.9
1.7
1.7
1.6
1.8
1.7
1.6
1.9
1.6
1.8
1.8
1.7
1.4
1.5
1.4
1.6
1.6
1.8
1.7
1.4
1.6
1.6
100 75 50
Efficiency %
at % full loadFull load I , 50HzN
380V 400V 415V
Current
(A) (A) (A)
Locked
rotor
I /IL N
Moment
of inertia
(kg m )
J=1/4 GD
x
2
2
Nosie
level
at1meter
dB(A)
Net
weight
(kg)
Locked
rotor
T /TL N
Pull
up
T /TU N
Break
down
T /TB N
Torque
Full
load
T
(Nm)N
Output
(kW)
Full
lock
speed
(rpm)
100 75 50
power factor, cos
at % full load
φFrame
Size
Performance data
12
8 Pole - 750 rpm synchronous speed 50Hz
750 r/min = 8 poles
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
185
220
630
640
660
660
690
690
690
710
710
720
720
720
730
730
730
740
740
740
740
740
740
740
740
740
740
740
740
740
0.88
1.15
1.48
2.16
2.41
3.35
4.4
5.90
7.80
10.2
13.6
17.7
25.4
34.0
41.0
47.2
63.3
77.5
94.1
110.8
150.1
177.4
216.4
259
315
393
363
425
0.84
1.09
1.41
2.05
2.29
3.18
4.20
5.60
7.40
9.70
12.9
16.8
24.1
32.3
39.0
44.8
60.1
73.6
89.4
105.3
142.6
168.5
205.6
246
298
370
342
410
0.81
1.05
1.36
1.98
2.21
3.07
4.00
5.40
7.10
9.30
12.5
16.2
23.3
31.1
37.5
43.2
58.0
71.0
86.2
101.5
137.4
162.4
198.1
240
292
361
334
390
2.9
3.0
3.4
3.5
3.5
3.6
3.9
4.3
4.4
4.4
5.0
5.7
5.6
5.5
5.6
5.4
5.3
5.6
5.2
5.7
5.9
6.2
6.0
5.03
5.28
5.42
5.29
4.76
51.2
54.2
62.21
63.1
70.5
72.4
74.5
79.3
80.1
81.6
83.3
85.9
87.8
88.3
90.2
90.8
91.2
91.8
92.0
93.1
93.7
94.0
94.2
94.6
94.7
94.8
94.8
94.8
46.5
49.2
61.3
62.5
70.0
71.9
74.0
78.7
79.8
81.1
82.9
85.6
87.4
88.0
89.8
90.4
90.9
91.3
91.5
92.9
93.4
93.6
93.8
94.5
94.5
94.6
94.6
94.6
38.9
39.3
54.6
55.8
63.6
69.5
72.0
77.6
78.1
79.7
81.7
83.7
85.5
86.3
87.8
88.3
88.9
88.8
89.4
91.3
91.9
92.1
92.4
91.9
92.2
92.3
92.3
92.3
0.61
0.61
0.61
0.61
0.67
0.69
0.70
0.71
0.73
0.73
0.74
0.75
0.75
0.76
0.76
0.78
0.79
0.79
0.79
0.81
0.81
0.82
0.82
0.82
0.81
0.82
0.82
0.83
0.56
0.55
0.54
0.53
0.53
0.57
0.62
0.64
0.64
0.66
0.66
0.68
0.69
0.72
0.72
0.75
0.76
0.75
0.74
0.77
0.78
0.76
0.80
0.79
0.78
0.81
0.79
0.82
0.47
0.47
0.45
0.43
0.44
0.46
0.49
0.53
0.52
0.57
0.55
0.55
0.58
0.62
0.65
0.66
0.68
0.66
0.65
0.70
0.70
0.70
0.71
0.71
0.72
0.75
0.73
0.76
2.8
3.7
5.4
8.0
10.4
15.2
20.8
29.6
40.4
53.1
73.0
99.5
144
196.3
242.1
284
387.3
477.7
581
710.1
968.3
1162
1420
1704
2066
2582
2388
2839
2.0
2.1
2.0
2.1
2.0
2.2
2.4
2.3
2.2
2.2
2.2
2.1
2.3
2.1
2.2
2.1
2.2
2.3
2.1
1.9
2.1
2.3
2.2
1.86
2.03
2.12
2.04
1.8
1.7
1.7
1.8
1.6
1.8
1.7
2.0
2.0
1.8
1.9
1.9
1.7
1.9
1.8
1.7
1.8
1.8
1.8
1.9
1.7
1.6
1.8
1.7
1.8
1.6
1.6
1.6
1.6
2.2
2.4
2.2
2.3
2.2
2.4
2.5
2.4
2.5
2.4
2.3
2.5
2.4
2.6
2.4
2.5
2.7
2.8
2.5
2.8
2.9
2.8
2.22
2.3
2.6
2.33
2.29
2.04
0.002
0.003
0.004
0.004
0.008
0.01
0.017
0.031
0.04
0.075
0.093
0.126
0.203
0.339
0.491
0.547
0.83
1.39
1.65
7.23
7.55
6.37
4.79
5.58
12.86
12.48
11.73
13.05
52
52
56
56
59
59
61
64
64
68
68
68
70
73
73
73
75
76
76
82
82
82
82
90
90
90
90
91
15
17
21
24
28
33
45
51
61
89
107
120
158
228
258
282
367
468
515
752
870
976
1096
1556
1704
1989
1876
2049
80M1
80M2
90S
90L
100L1
100L2
112M1
132S2
132M1
160M1
160M2
160L
180L
200L
225S
225M
250M
280S
280M1
315S
315M
315L1
315L2
355M1
355M2
355L2
355L1
355L
100 75 50
Efficiency %
at % full loadFull load I , 50HzN
380V 400V 415V
Current
(A) (A) (A)
Locked
rotor
I /IL N
Moment
of inertia
(kg m )
J=1/4 GD
x
2
2
Nosie
level
at1meter
dB(A)
Net
weight
(kg)
Locked
rotor
T /TL N
Pull
up
T /TU N
Break
down
T /TB N
Torque
Full
load
T
(Nm)N
Output
(kW)
Full
lock
speed
(rpm)
100 75 50
power factor, cos
at % full load
φFrame
Size
Performance data
Frame size from 80 to 132
Frame size from 225 to 280
Frame size from 315 to 355
Frame size from 160 to 200
Dimensions foot mount B3
13
GD
G
F
D
DH
GD
GF
D
DH
GD
G
F
D
DH
GD
G
F
D
DH
AC
BB
BCE
ED
LG 2xKK
L
AC
BB
BCE
ED
LG2xKK
L
H
HA
AB
A KAA
HD
AG
AC
BB
BCE
ED
LG 2xKK
L
AC
BB
BCE
ED
LG2xKK
L
HD
H
HA
AB
A
AG
K AA
H
HA
AB
AK AA
HD
AG
HD
H
HA
AB
A
KAA
AG
14
Dimensions foot mount B3
‘*’ Means that the cable gland is only one.
125
140
140
160
190
216
216
254
254
279
279
318
356
356
356
406
406
457
457
457
457
508
508
508
508
508
508
610
610
610
610
610
610
34
36
36
40
45
52
52
67
67
74
74
75
80
80
80
88
88
90
90
90
90
120
120
120
120
120
120
125
125
125
125
125
125
160
180
180
200
230
265
265
320
320
350
350
395
436
436
436
495
495
550
550
550
550
635
635
635
635
635
635
735
735
735
735
735
735
175
190
190
215
236
275
275
330
330
380
380
420
465
465
465
520
520
570
570
570
570
650
650
650
650
650
650
735
735
735
735
735
735
51
60
60
60
75
75
75
95
95
95
95
120
120
120
120
160
160
160
160
160
160
195
195
195
195
195
195
330
330
330
330
330
330
100
100
125
140
140
140
178
210
254
241
279
286
305
311
311
349
349
368
368
419
419
406
457
508
406
457
508
560
630
560
560
630
630
130
135
160
182
195
205
245
260
305
297
335
370
355
380
380
515
440
440
494
494
535
535
515
625
625
625
625
675
775
775
775
775
775
50
56
56
63
70
89
89
108
108
121
121
133
149
149
149
168
168
190
190
190
190
216
216
216
216
216
216
254
254
254
254
254
254
100
19
24
24
28
28
38
38
42
42
48
48
55
60
55
60
60
65
65
75
65
75
65
75
65
80
80
80
75
75
95
95
100
*M6X16
*M8X19
*M8X19
*M10X22
M10X22
M12X28
M12X28
M16X36
M16X36
M16X36
M16X36
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M24X50
M24X50
M24X50
M24X50
M24X50
M24X50
40
50
50
60
60
80
80
110
110
110
110
110
140
110
140
140
140
140
140
140
140
140
140
140
170
170
170
140
140
170
170
210
210
22
32
32
40
40
56
56
80
80
80
80
90
100
80
100
100
100
100
100
100
100
100
100
100
130
130
130
140
110
110
160
140
160
6
8
8
8
8
10
10
12
12
14
14
16
18
16
18
18
18
18
18
18
18
18
20
20
22
22
22
20
20
25
28
25
28
67.5
67.5
15.5
20
20
24
24
33
33
37
37
42.5
42.5
49
53
49
53
53
58
58
67.5
58
67.5
58
58
58
71
71
71
86
86
90
90
6
7
7
7
7
8
8
8
8
9
9
10
11
10
11
11
11
11
12
11
12
11
11
11
14
14
14
12
12
14
16
14
16
80
90
90
100
112
132
132
160
160
180
180
200
225
225
225
250
250
280
280
280
280
315
315
315
315
315
315
355
355
355
355
355
355
10
12.5
12.5
14
14
16
16
19
19
22
22
25
28
28
28
33
33
35
35
35
35
45
45
45
45
45
45
49
49
49
49
49
49
230
260
260
275
310
350
350
425
425
460
460
515
560
560
560
620
620
685
685
685
685
820
820
820
820
820
820
1000
1000
1000
1000
1000
1000
10
10
10
12
12
12
12
14.5
14.5
14.5
14.5
18.5
18.5
18.5
18.5
24
24
24
24
24
24
28
28
28
28
28
28
28
28
28
28
28
28
M24X1.5
M24X1.5
M24X1.5
M24X1.5
M64X25
M30X2
M30X2
M30X2
M36X2
M36X2
M36X2
M36X2
M48X2
M48X2
M48X2
M48X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
295
320
345
385
410
480
520
610
655
680
720
760
825
820
850
925
925
960
975
1000
1015
1160
1270
1270
1190
1300
1300
1500
1500
1530
1570
1530
1570
168.5
140
156
193
200
239
258
270
270
270
277
298
338
338
338
360
360
344
344
344
344
417
417
417
417
417
417
420
420
450
490
450
490
Framesize
A AA AB AC AG B BB C D DH E ED F G GD H HA HD K KK LGLAD
150
140
150
160
185
205
205
250
250
270
270
325
335
335
335
370
370
395
395
395
395
495
495
495
495
495
495
640
640
640
640
640
640
1) 2 Pole motors only.
2) These motor can also be supplied. Please state the
dimensions of the shaft extension on order.
80
90S
90L
100L
112M
132S
132M
160M
160L
180M
180L
200L
225S
225M
225M
250M
250M
280S
280S
280M
280M
315S
315M
315L
315S
315M
315L
355M
355L
355M
355M
355L
355L
1)
1)
1)
1)
1)
1)
1)
1)
1)
2)
2)
The “R” dimension is zero.
15
Dimensions foot-flange mount B35
Frame size from 80 to 132
Frame size from 160 to 200
Frame size from 225 to 280
Frame size from 315 to 355
2xKK
AC
NP
BB
BCE
R
ED
LA
LG
L
AC
NP
BB
BCER
T
LA
LG
ED
2xKK
L
NP
C
E
R
AC
BB
B
ED
LGLA
T
2xKK
L
NP AC
BB
BCR
E
LG
ED
LA
T
2xKK
L
GD
G
F
D
DH
GD
G
F
D
DH
GD
G
F
D
DH
GD
G
F
D
DH
45
o
AG
SM
HD
H
HA
AA
AB
A
K
HD
H
HA
AB
A
M
S
22.5
o
AA K
AG
16
Dimensions foot-flange mount B35
80
90S
90L
100L
112M
132S
132M
160M
160L
180M
180L
200L
225S
225M
225M
250M
250M
280S
280S
280M
280M
315S
315M
315L
315S
315M
315L
355M
355L
355M
355M
355L
355L
125
140
140
160
190
216
216
254
254
279
279
318
356
356
356
406
406
457
457
457
457
508
508
508
508
508
508
610
610
610
610
610
610
A
34
36
36
40
45
52
52
67
67
74
74
80
80
80
80
88
88
90
90
90
90
120
120
120
120
120
120
125
125
125
125
125
125
160
180
180
200
230
265
265
320
320
350
350
395
436
436
436
495
495
550
550
550
550
635
635
635
635
635
635
735
735
735
735
735
735
ABAA
175
190
190
215
236
275
275
330
330
380
380
420
465
465
465
520
520
570
570
570
570
650
650
650
650
650
650
735
735
735
735
735
735
AC
140
150
150
160
185
205
205
250
250
270
270
325
335
335
335
370
370
395
395
395
395
495
495
495
495
495
495
640
640
640
640
640
640
AD
100
100
125
140
140
140
178
210
254
241
279
286
305
311
311
349
349
368
368
630
419
419
406
457
508
406
457
508
560
560
560
630
560
B
130
135
160
182
195
205
245
260
297
305
335
370
355
380
380
440
440
494
494
535
535
515
625
625
515
625
625
675
775
775
775
775
775
BB
50
56
56
63
70
89
89
108
108
121
121
133
149
149
149
168
168
190
190
190
190
216
216
216
216
216
216
254
254
254
254
254
254
C
19
24
24
28
28
38
38
42
42
48
48
55
55
75
75
80
80
60
60
60
65
65
65
65
65
65
65
75
75
95
95
100
100
D
*M6X16
*M8X19
*M8X19
*M10X22
M10X22
M12X28
M12X28
M16X36
M16X36
M16X36
M16X36
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X50
M20X50
M24X50
M24X50
M24X50
M24X50
DH
40
50
50
60
60
80
80
110
110
110
110
110
140
110
140
140
140
140
140
140
140
140
140
140
170
170
170
140
140
170
170
210
210
E
22
32
32
40
40
56
56
80
90
80
80
90
100
80
100
100
100
100
100
100
100
100
100
100
130
130
130
110
110
140
160
140
160
ED
6
8
8
8
8
10
10
12
12
14
14
16
18
16
18
18
18
18
20
20
18
18
18
18
22
22
22
20
20
25
28
25
28
F
15.5
86
42.5
42.5
20
20
24
24
33
33
37
37
49
49
67.5
53
53
53
58
58
58
58
58
58
71
71
71
67.5
67.5
67.5
86
90
90
G
6
7
7
7
7
8
8
8
8
9
9
10
11
10
11
11
11
11
12
11
12
11
11
11
14
14
14
12
12
14
16
14
16
GD
80
90
90
100
112
132
132
160
160
180
180
200
225
225
225
250
250
280
280
280
280
315
315
315
315
315
315
355
355
355
355
355
355
H
10
12.5
12.5
14
14
16
16
19
19
22
22
25
28
28
28
33
33
35
35
35
35
45
45
45
45
45
45
49
49
49
49
49
49
HA
230
260
260
275
310
350
350
425
425
460
460
515
560
560
560
620
620
685
685
685
685
820
820
820
820
820
820
1000
1000
1000
1000
1000
1000
HD
18.5
18.5
14.5
14.5
14.5
14.5
18.5
18.5
10
10
10
12
12
12
12
24
24
24
24
24
24
28
28
28
28
28
28
28
28
28
28
28
28
K
M24X1.5
M24X1.5
M24X1.5
M24X1.5
M30X2
M30X2
M30X2
M36X2
M36X2
M36X2
M36X25
M48X2
M48X2
M48X2
M48X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64x2
M64X2
M64X2
M64X2
M64X2
KK
140
156
168.5
193
200
239
258
270
270
277
277
298
338
338
338
360
360
344
344
344
344
417
417
417
417
417
417
420
420
450
490
450
490
LG
295
320
345
385
410
480
520
610
655
680
720
760
825
850
850
925
925
960
975
1000
1015
1160
1270
1270
1190
1300
1300
1500
1500
1530
1570
1530
1570
L
12
12
12
14
14
14
14
15
15
15
15
17
19
19
19
20
20
22
22
22
22
24
24
24
24
24
24
25
25
25
25
25
25
LA
165
165
165
215
215
265
265
300
300
300
300
350
400
400
400
500
500
500
500
500
500
600
650
600
600
600
600
740
740
740
740
740
740
M
130
130
130
180
180
230
230
250
250
250
250
300
350
350
350
450
450
450
450
450
450
550
550
450
550
550
550
680
680
680
680
680
680
N
200
200
200
250
250
300
300
350
350
350
350
400
450
450
450
550
550
550
550
550
550
660
660
550
660
660
660
800
800
800
800
800
800
P
12
12
12
14.5
14.5
14.5
14.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
24
24
24
24
24
24
24
24
24
24
24
24
S
3.5
3.5
3.5
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
TAG
51
60
60
60
75
75
75
95
95
95
95
120
120
120
120
160
160
160
160
160
160
195
195
195
195
195
195
330
330
330
330
330
330
‘*’ Means that the cable gland is only one.1) 2 Pole motors only.
2) These motor can also be supplied. Please state the
dimensions of the shaft extension on order.
The “R” dimension is zero.
1)
1)
1)
1)
1)
1)
1)
1)
1)
2)
2)
Framesize
17
Frame size from 315 to 355
Frame size from 225 to 280
Frame size from 160 to 200
Frame size from 80 to 132
AC
P N
R
E
LG
ED
LA
T
2xKK
L
P N
E
R
LG
ED
LAT
L
LM
AC
2xKK
AG
S
M
P N
ER
LG
LA
T
L
LM
AC
ED
2xKK
ADM
S
AG
AC
2xKK
L
LM
P N
LG
LA
T
E
AG
M
AD
S
GD
G
F
D
DH
GD
G
F
D
DH
GD
G
F
D
DH
GD
G
F
D
DH
Dimensions flange mount B5 and V1
18
Dimensions flange mount B5 and V1
Framesize
LA
355M(V1)
355L(V1)
355M(V1)
355M(V1)
355L(V1)
355L(V1)
AC
175
190
190
215
236
275
275
330
330
380
380
420
465
465
465
520
520
570
570
570
570
650
650
650
650
650
650
735
735
735
735
735
735
AD
140
150
150
160
185
205
205
250
250
270
270
325
335
335
335
370
370
400
400
400
400
495
495
495
495
495
495
645
645
645
645
645
645
AG
51
60
60
60
75
75
75
95
95
95
95
120
120
120
120
160
160
160
160
160
160
195
195
195
195
195
195
330
330
330
330
330
330
D
19
24
24
28
28
38
38
42
42
48
48
55
60
60
60
55
65
65
75
65
75
65
65
65
80
80
80
75
75
95
100
95
100
DH
M6X16
M8X19
M8X19
M10X22
M10X22
M12X28
M12X28
M16X36
M16X36
M16X36
M16X36
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M20X42
M24X50
M24X50
M24X50
M24X50
M24X50
M24X50
E
40
50
50
60
60
80
80
110
110
110
110
110
140
110
140
140
140
140
140
140
140
140
140
140
170
170
170
140
140
170
170
210
210
ED
22
32
32
40
40
56
56
80
80
80
80
90
80
100
100
100
100
100
100
100
100
100
100
100
130
130
130
110
110
140
160
140
160
F
6
8
8
8
8
10
10
12
12
14
14
16
18
16
18
18
18
18
18
18
18
18
20
20
22
22
22
20
20
25
28
25
28
G
15.5
86
42.5
42.5
20
20
24
24
33
33
37
37
49
49
58
53
53
53
58
58
58
58
58
71
71
71
67.5
67.5
67.5
67.5
86
90
90
GD
6
7
7
7
7
8
8
8
8
9
9
10
11
10
11
11
11
11
12
11
12
11
11
11
14
14
14
12
12
14
16
14
16
KK
*M24X1.5
*M24X1.5
*M24X1.5
*M24X1.5
M30X2
M30X2
M30X2
M36X2
M36X2
M36X2
M36X2
M48X2
M48X2
M48X2
M48X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
M64X2
L
295
320
345
385
410
480
520
610
655
685
720
760
825
820
850
925
925
960
975
1000
1015
1160
1270
1270
1190
1300
1300
1500
1500
1530
1570
1530
1570
LG
140
156
168.5
193
200
239
258
270
270
277
277
298
338
338
338
360
360
344
344
344
344
417
417
417
417
417
417
420
420
450
490
450
490
LM
1630
-
-
-
-
-
-
-
665
720
755
795
845
894
889
919
1051
1051
1090
1090
1090
1090
1258
1368
1368
1288
1398
1398
1600
1600
1630
1670
1670
12
12
12
14
14
14
14
15
15
15
15
17
19
19
19
20
20
22
22
22
22
24
24
24
24
24
24
25
25
25
25
25
25
M
165
165
165
215
215
265
265
300
300
300
300
350
400
400
400
500
500
500
500
500
500
600
600
600
600
600
600
740
740
740
740
740
740
N
130
130
130
180
180
230
230
250
250
250
250
300
350
350
350
450
450
450
450
450
450
550
550
550
550
550
550
680
680
680
680
680
680
P
200
200
200
250
250
300
300
350
350
350
350
400
450
450
450
550
550
550
550
550
550
660
660
660
660
660
660
800
800
800
800
800
800
S
12
12
12
14.5
14.5
14.5
14.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
24
24
24
24
24
24
24
24
24
24
24
24
T
3.5
3.5
3.5
4
4
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
6
‘*’ Means that the cable gland is only one.1) 2 Pole motors only.
2) These motor can also be supplied. Please state the
dimensions of the shaft extension on order.
The “R” dimension is zero.
1)
1)
1)
1)
1)
1)
80
90S
90L
100L
112M
132S
132M
160M
160L
180M
180L
200L
225S
225M
225M
250M
250M
280S
280S
280M
280M
315S
315M
315L
315S
315M
315L
1)
1)
1)
2)
2)
Dimensions face-flange mount B14A and B14B
Frame size from 80 to 160 B14A
Frame size from 80 to 112 B14B
19
AC
L
P N
R
E
LG
ED
T
2xKK
GD
G
F
D
DH
P N
R
T
AC
E
ED
LG
L
2xKKG
DG
F
D
DH
Frame
sizeM N P S T M N P S T
80 100 80 120 M6 3 130 110 160 M8 3.5
90S 115 95 140 M8 3 130 110 160 M8 3.5
90L 115 95 140 M8 3 130 110 160 M8 3.5
100L 130 110 160 M8 3.5 165 130 200 M10 3.5
112M
AC
175
190
190
215
236
AD
150
165
165
170
195
AG
51
60
60
60
75
D
19
24
24
28
28
DH
M6X16
M8X19
M8X19
M10X22
M10X22
E
40
50
50
60
60
ED
22
32
32
40
40
F
6
8
8
8
8
G
15.5
20
20
24
24
GD
6
7
7
7
7
KK
*M24X1.5
*M24X1.5
*M24X1.5
*M24X1.5
M30X2
L
295
320
345
385
410
LG
140
156
168.5
193
200 130 110 160 M8 3.5 165 130 200 M10 3.5
B14A B14B
160M 330 265 95 42 M16X36 110 80 12 37 8 M36X2 610 270 215 180 250 M12 4 265 230 300 M12 4
132M 275 215 75 38 M12X28 80 56 10 33 8 M30X2 520 258 165 130 200 M10 3.5 215 180 250 M12
132S 275 215 75 38 M12X28 80 56 10 33 8 M30X2 480 239 165 130 200 M10 3.5 215 180 250 M12 4
160L 330 265 95 42 M16X36 110 80 12 37 8 M36X2 655 270 215 180 250 M12 4 265 230 300 M12 4
4
‘*’ Means that the cable gland is only one.
The “R” dimension is zero.
Frame size from 160 to 31531 4
C
6 7 8
B
A
C
4321
B
A
5 7 86
B
5 6 87Frame size 355
A
C
1 2 3 4
Terminal box
20
Frame
sizeA B C 1 2 3 4 5 6 7 8
80~90 104 104 48 M6X16 M4 M6X25 M6X12 M6X12 M5X16 2XM25X1.5 2XPG16
100~132 118 181 62 M6X16 M5 M6X25 M6X12 M6X12 M5X16 2XM32X1.5 2XPG21
160~180 200 164 83 M6X20 M3 M8 M8X30 M4X25 M8X16 M8X16 M5X16 2XM40X1.5 2XPG29
200~225 285 190 109 M8X30 M3 M10 M8X30 M4X25 M8X16 M8X16 M6X20 2XM50X1.5 2XPG36
250~280 284 218 119 M8X30 M3 M10 M10X30 M4X25 M10X20 M10X20 M6X25 2XM63X1.5 2XPG42
315 441 326 195 M8X30 M3 M12 M10X50 M4X25 M10X16 M10X20 M8X30 2XM63X1.5 2XPG48
315 490 365 220 M8X30 M3 M16 M10X25 M4X25 M10X25 M10X25 M8X30 2XM63X1.5 2XPG48
Metric Gland
Sizes
PG Gland
Sizes
21
Bearing and oil seal
Bearing data
D d
B
DE NDE d D B
80 6204 ZZ C3 6204 ZZ C3 20 47 14
90 6205 ZZ C3 6205 ZZ C3 25 52 15
100 6206 ZZ C3 6206 ZZ C3 30 62 16
112 6306 ZZ C3 6306 ZZ C3 30 72 19
132 6308 ZZ C3 6308 ZZ C3 40 90 23
160 6309 C3 6309 C3 45 100 25
180 6311 C3 6311 C3 55 120 29
200 6312 C3 6312 C3 60 130 31
225 6313 C3 6313 C3 65 140 33
250 6314 C3 6314 C3 70 150 35
280 2P 6314 C3 6314 C3 70 150 35
280 4-8P 6316 C3 6316 C3 80 170 39
(Horizontal)315 2P 6316 C3 6316 C3 80 170 39
315 4-8P (Horizontal) NU319 C3 6319 C3 95 200 45
315 4-8P (Vertical) NU319 C3 7319 95 200 45
355 4-8P (Horizontal) NU322 C3 6322 C3 110 240 50
355 4-8P (Vertical) NU322 C3 7322 110 240 50
315 2P (Vertical) 6316 C3 7316 80 170 39
355 2P (Horizontal) 6319 C3 6319 C3 95 200 45
355 2P (Vertical) 6319 C3 7319 95 200 45
Oil seal data
B
d D
Frame sizeFrame size DE NDE
d D DdB B
80 20 35 5 20 35 5
90 25 40 5 25 40 5
100 30 52 7 30 52 7
112 30 52 7 30 52 7
132 40 62 5 40 62 5
160 45 65 8 45 65 8
180 55 75 8 55 75 8
200 60 80 8 60 80 8
225 65 90 10 65 90 10
250 70 95 10 70 95 10
280 2P 70 95 10 70 95 10
280 4-8P 80 100 10 80 100 10
315-2P 80 100 10 80 100 10
315 4-8P 95 120 12 95 120 12
355 2P 95 120 12 95 120 12
355 4-8P 110 140 12 110 140 12
22
Notes:* 2 Pole motors only.1. Vertical motors should be greased twice as often as horizontal motors.2. Regreasing time should be reduced if bearing operating temperature is in excess of 70 C.
0
Enertech Electric Motors (Australia) reserves right to make changes to this brochure without notice.
Bearing lubrication
Frame
size
Drive
end bearing
Non–drive
end bearing
Regreasing period hours for
operating temperatures up to 70°C
Quantity of
grease in
bearing chamber
rpm<3600 rpm<1800 rpm<1200 grams
160 6309 C3 6309 C3 6000 12000 18000 13
180 6311 C3 6311 C3 4000 11000 16000 15
200 6312 C3 6312 C3 3500 8500 13000 20
225 6313 C3 6313 C3 3000 6000 9000 22
250 6314 C3 6314 C3 2000 5000 8000 23
280* 6314 C3 6314 C3 1200 – – 30
315* 6316 C3 6316 C3 1200 – – 30
355* 6319 C3 6319 C3 1200 – – 30
280 6316 C3 6316 C3 – 4000 6000 30
315 NU319 C3 6319 C3 – 2000 3000 45
355 NU322 C3 6322 C3 – 1400 2200 60
1
4
5
6
7
8
2
3
1011
12
1314
15
16
17
18
9
Motors of frame sizes 160–355 are fitted with open bearings and regreasing device. Depending on the useful
life of grease, open bearings must be regreased in good time so that the scheduled bearing service life is
reached.
ESC motors are equipped with bearings from excellent manufacturers.
In general the bearings have C3 clearances.
Motors of frame sizes 80–132 are fitted with life–lubricated bearings.
1. Endshield D.E2. Flange3. Oil seal4. Terminal Box Lid5. Seal Gasket
6. Terminal Box Base7. Terminal Board8. Terminal Gasket9. Stator10. Key
11. Bearing D.E12. Rotor13. Inner Bearing Cap14. Bearing N.D.E
15. Endshield N.D.E16. Fan17. Snap Ring18. Fan Cowl
Enertech Electric Motors Products are sold and recommended by :
HEAD OFFICE
Address:
Tel:
Fax:
5 Kintyre Court, Greenvale 3059, Victoria, Australia.
+ 61 (0)3 9333 6605
+ 61 (0)3 9333 6603