Es455 Update Inst

16
8 © 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455 FIRMWARE UPDATING 8 - 5 8.1 Firmware Updating with USB Media Firmware can be updated by storing update programs and firmware data files in the USB media. Program necessary for updating Firmware type and data file name for updating Equipment Store the update program loader (mentusb2.o) in the root directory, and store the model specific update program (dlFirmWare_205_455) and the data file for updating in the model specific folder. Fig. 8-1 Notes: Since the date and time set in the equipment are recorded in the firmware update log, make sure that they are correct before updating the firmware. Never change the model specific folder name, since it is used for identifying the data file when the data files used for updating multiple models are stored in the USB media. Update program Data file name Remarks Update program loader mentusb2.o An error occurs at a time of the [4] + [9] startup, unless this program is stored in the USB media. * Be sure to save this data file to the root directory of the USB media. Model specific update program dlFirmWare_205_455 An error occurs at a time of the [4] + [9] startup, unless this program is stored in the USB media. Firmware Stored Data file name Remarks System ROM System control PC board (SYS board) firmImage0.bin OS data Master data Hard disk hdd.bin HDD program data, System firmware, UI data Engine ROM Logic PC board (LGC board) T470MWW.xxx * xxx is version. Main firmware Scanner ROM Scanning section control PC board (SLG board) T471SLGWW.xxx * xxx is version. Scanner firmware Model specific folder name 205_455 205_455 dlFirmWare_205_455 mentusb2.o T470MWW.xxx T471SLGWW.xxx firmImage0.bin hdd.bin USB media You must use the mentusb2.o that came with the 855 Series or the 455 Series firmware package. mentusb2.o from 6530c Series or 4520c Series will NOT work.

description

update toshiba e455

Transcript of Es455 Update Inst

  • 8

    2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455FIRMWARE UPDATING

    8 - 5

    8.1 Firmware Updating with USB MediaFirmware can be updated by storing update programs and firmware data files in the USB media.

    Program necessary for updating

    Firmware type and data file name for updatingEquipment

    Store the update program loader (mentusb2.o) in the root directory, and store the model specific update program (dlFirmWare_205_455) and the data file for updating in the model specific folder.

    Fig. 8-1

    Notes: Since the date and time set in the equipment are recorded in the firmware update log, make

    sure that they are correct before updating the firmware. Never change the model specific folder name, since it is used for identifying the data file when

    the data files used for updating multiple models are stored in the USB media.

    Update program Data file name RemarksUpdate program loader mentusb2.o An error occurs at a time of the [4] + [9]

    startup, unless this program is stored in the USB media.* Be sure to save this data file to the

    root directory of the USB media.Model specific update program dlFirmWare_205_455 An error occurs at a time of the [4] + [9]

    startup, unless this program is stored in the USB media.

    Firmware Stored Data file name RemarksSystem ROM System control PC

    board(SYS board)

    firmImage0.bin OS data

    Master data Hard disk hdd.bin HDD program data, System firmware, UI data

    Engine ROM Logic PC board(LGC board)

    T470MWW.xxx* xxx is version.

    Main firmware

    Scanner ROM Scanning section control PC board(SLG board)

    T471SLGWW.xxx* xxx is version.

    Scanner firmware

    Model specific folder name 205_455

    205_455

    dlFirmWare_205_455

    mentusb2.o

    T470MWW.xxxT471SLGWW.xxx

    firmImage0.binhdd.bin

    USB media

    You must use the mentusb2.o that came with the 855 Series or the 455 Series firmware package. mentusb2.o from 6530c Series or 4520c Series will NOT work.

  • e-STUDIO205L/255/305/355/455 2009 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING

    8 - 6

    Important: Only the USB media which meet the following conditions should be used for updating. Be

    careful since updating with any device other than the above is never guaranteed.- A combination USB media with a flash memory (to be connected directly to the USB port)

    and its capacity is between 256 MB and 512 MB (or 1 GB).- Operation of the USB media used for updating has been confirmed at the input check of

    this equipment (Test mode 03).( P.2-4 "2.2 Input Check (Test Mode 03)")

    - USB media which comply with the following standards regulated by USB-IF (USB Implementers Forum)Class number: 8 (=08h) (Mass-storage class)Sub-class number: 6 (=06h) (SCSI transfer command set)Protocol number: 80 (=50h) (Bulk-Only)* Most common USB media comply with the specification above and can be used for

    updating. However, the operation in all the Multi Functional Digital Color Systems and Multi Functional Digital Systems is not necessarily guaranteed since the most of these devices are developed based on use in a PC environment (Windows or Macintosh). Therefore, check thoroughly that the device is operational in the equipment for which the updating will be performed when purchasing it.

    The USB media complying with USB1.1 and USB2.0 can be used for updating.

    Do not update the firmware by any storage device other than a flash memory (such as a USB connection type memory card reader, CD/DVD drive or hard disk), since it is never guaranteed.

    It is possible to store the model specific update program and the data file for updating directly in the root directory when you store the updating data file for one specific model in the USB media. However, if the model specific folder for the same model as that of the data file stored in the root directory already exists, this will have priority.

  • 8

    2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455FIRMWARE UPDATING

    8 - 7

    8.1.1 Master data/System ROM/Engine ROM/Scanner ROMImportant:

    The file system of USB media should be formatted in the FAT or FAT32 format. Be careful since the devices formatted in NTFS format will not be able to be operated. The file system can be confirmed on the properties in applications such as Explorer of Windows.

    Never shut down the equipment during the update. Firmware data and the following option data (if installed) could be damaged and may not be able to be operated properly.- Data Overwrite Enabler (GP-1070)- Meta Scan Enabler (GS-1010)- External Interface Enabler (GS-1020)- IPSec Enabler (GP-1080)

    [A] Update procedure

    (1) Connect the USB media to the PC and write the model specific folder in which the data file is stored.Store the update program loader (mentusb2.o) in the root directory, and store the model specific update program (dlFirmWare_205_455) and the data file for updating in the model specific folder.

    (2) Press the [ON/OFF] button on the control panel to shut down the equipment and turn the power OFF using the main power switch.

    (3) Connect the USB media to the USB port on the right upper cover.

    Fig. 8-2

    Note: Updating cannot be performed with multiple USB media connected at the same time.

    (4) Turn the power ON using the main power switch while simultaneously holding down the [4] and [9] buttons.Data in the USB media are checked and the checking status is displayed on the screen.

    The screen for selecting items to be updated is displayed after approx. 1 minutes. On this screen, the current firmware version of this equipment and the firmware version of data to be updated are displayed.

    USB media

    USB port

  • e-STUDIO205L/255/305/355/455 2009 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING

    8 - 8

    Fig. 8-3

    Notes: The display of items on this screen varies depending on the types of data written on the USB

    media. Each item is displayed only when each data file is written on the USB media in the following conditions.

    For "2. HDD SYS Update", "3. Engine Main Firmware Update" and "4. Scanner Firmware Update", an asterisk (*) indicating that the item to be installed is not displayed next to one already installed in the same version as that of the update data for the purpose of efficiency, and this will not happen in the standard setting. If you want to install it, select it manually before starting the update.

    If the USB media are not recognized properly, Set Correct USB Storage Device message is displayed. In this case, disconnect the USB media and connect again within 3 minutes, or shut down the equipment and connect the device properly. Then repeat the procedure from (4).

    If any of the error messages below is displayed, confirm if the update program or the data file in the USB media is correct. Then repeat the procedure from (4).

    Item Condition1. OS Update firmImage0.bin is written.2. HDD SYS Update hdd.bin is written.3. Engine Main Firmware Update T470MWW.xxx is written.

    * xxx is version.4. Scanner Firmware Update T471SLGWW.xxx is written.

    * xxx is version.

    Error number Error message Cause

    - There is no mentusb2.o Update program loader (mentusb2.o) is not stored.

    01 There is no dlFirmWare_205_455 in the storage device.

    Model specific update program (dlFirmWare_205_455 ) is not stored.

    01 There is no dlFirmWare_xxx_xxx in the storage device.* The model name comes at xxx_xxx.

    The jumper line on the SYS board is set for another model.

    02 Error Loadmodule Module loading failed.03 Machine Model Get Error Model information was not

    downloaded.04 Please Change USB Storage or Please Check

    ROMDATAChecking of data file failed.

    05 Other models ROMDATA Vxxxx.xxx x* The version name comes at xxxx.xxx.x.

    Master data of other model (hdd.bin) are stored.

  • 8

    2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455FIRMWARE UPDATING

    8 - 9

    (5) Select the item with the digital keys.* is displayed next to the selected item. Display or delete the * by pressing the number of the item.

    (6) Press the [START] button.Updating starts and the processing status is displayed on the LCD screen.

    (7) Update Completed. is displayed at the bottom of the LCD screen after the updating is completed properly.

    Fig. 8-4

    Item Remarks1. OS Update Updating OS data2. HDD SYS Update Updating Master data and System data3. Engine Main Firmware Update Updating Engine ROM4. Scanner Firmware Update Updating Scanner ROM

    Status display during update Status display when update is completed OS Update.......................... FROM write OS Update.......................... CompletedHDD SYS Update ............... Copy file HDD SYS Update ............... CompletedEngine Firm Update........... Flash Update Engine Firm Update........... CompletedScanner Firm Update ..........Flash Update Scanner Firm Update ..........Completed

  • e-STUDIO205L/255/305/355/455 2009 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING

    8 - 10

    Notes: Update Failed. is displayed at the bottom of the LCD screen when the updating is not

    completed properly. Failed appears next to the failed item on the status display. In this case, shut down the equipment after all the updates are stopped (when either Completed or Failed is displayed for each item), and then check the following.- Do the USB media meet the conditions to be used for updating?- Is the data file written properly on the USB media?- Are the USB media installed properly?- Do the USB media and equipment operate properly?

    When an error occurred and the update failed, Update Failed or Failed appears on the screen and an error code appears next to the message. The content of each error code is shown below.

    OS update ErrorError number Error content

    O01 FROM writing failed

    O02 FROM verification error

    O03 File operation error

    O04 SRAM flag set error

    O06 Device error

    HDD update ErrorError number Error content

    H01 File creation error

    H02 File decompression error

    H03 Partition mount error

    H00 Other errors

    Engine update ErrorError number Error message Error content

    M01 Time out(When the download is requested)Communication timeout(When the download is requested)

    M02 Time out(When the download is written)Communication timeout(When the download is written)

    M03 Time out(When the download is finished)Communication timeout(When the download is finished)

    M04 Reception failed(When the download is requested)Downloading request was denied.(When the download is requested)

    M05 Deletion error(When the download is written)Deletion error(When the download is written)

    M06 Writing error(When the download is written)Writing error(When the download is written)

    M07 Checksum error(When the download is finished)Checksum error(When the download is finished)

    M08 Reception status code abnormality(When the download is requested)Reception status code abnormality(When the download is requested)

    M09 Reception status code abnormality(When the download is written)Reception status code abnormality(When the download is written)

    M10 Reception status code abnormality(When the download is finished)Reception status code abnormality(When the download is finished)

    M00 Other error Other error

  • 8

    2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455FIRMWARE UPDATING

    8 - 11

    (8) Press the [ON/OFF] button on the control panel to shut down the equipment, and then remove the USB media.

    Note: When the equipment has been shut down normally, the LCD screen and LEDs (green and red) go OFF. When OS data have been updated and the equipment has been shut down immediately after the update, the LEDs (green and red) may not go OFF even if the LCD screen goes OFF. This indicates that the equipment is not shut down normally. Press the [ON/OFF] button on the control panel for more than 5 seconds, and then turn the main switch OFF. Then remove the USB media.

    (9) Perform the initialization of the updating data. Press the [ON/OFF] button on the control panel while [0] button and [8] button are pressed

    simultaneously. Key in 947, and then press the [START] button. Press the [INITIALIZE] button.

    [B] Confirmation of the updated dataAfter the updating is completed, check each data version in the Setting Mode (08) to confirm that the data were overwritten properly.

    P.8-50 "8.4 Confirmation of the updated data"

    Scanner update ErrorError number Error message Error content

    S01 Time out(When the download is requested)Communication timeout(When the download is requested)

    S02 Time out(When the download is written)Communication timeout(When the download is written)

    S03 Time out(When the download is finished)Communication timeout(When the download is finished)

    S05 Deletion error(When the download is written)Deletion error(When the download is written)

    S06 Writing error(When the download is written)Writing error(When the download is written)

    S08 Reception status code abnormality(When the download is requested)Reception status code abnormality(When the download is requested)

    S09 Reception status code abnormality(When the download is written)Reception status code abnormality(When the download is written)

    S10 Reception status code abnormality(When the download is finished)Reception status code abnormality(When the download is finished)

    S00 Other error Other error

  • e-STUDIO205L/255/305/355/455 2009 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING

    8 - 12

    [C] Display during the updateUpdate is performed in parallel as shown in the transition diagram below.

    Fig. 8-5

    Below is an example of the changes of the LCD screen during update.System ROM

    Fig. 8-6

    3. Engine MainFirmware Update

    4. Scanner

    Firmware Update1. OS Update 2. HDD SYS Update

    Item Selection Screen for Update

    [System ROM] [Master data] [Engine ROM] [Scanner ROM]

    Update Completed

  • 8

    2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455FIRMWARE UPDATING

    8 - 13

    Master data

    Fig. 8-7

  • e-STUDIO205L/255/305/355/455 2009 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING

    8 - 14

    Engine ROM

    Fig. 8-8

  • 8

    2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455FIRMWARE UPDATING

    8 - 15

    Scanner ROM

    Fig. 8-9

  • e-STUDIO205L/255/305/355/455 2009 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING

    8 - 50

    8.4 Confirmation of the updated dataAfter the updating is completed, check each data version in Setting Mode (08) to confirm that the data were overwritten properly.

    The installed ROM versions and the registered optional Electronic License Keys can be confirmed in the list print mode following the procedure below.

    (1) Turn the power ON using the main power switch while pressing the digital key [9] and the [START] button simultaneously.* When the equipment is already in the other setting mode, press the [ON/OFF] button on the

    control panel instead of using the main switch.

    (2) Key in 1 three times, and then press the [START] button.

    (3) VERSION LIST is printed out.* It is recommended to keep this list for future reinstallation such as the replacement of the SYS

    board.

    (4) Keep pressing the [ON/OFF] button until you hear a sound to shut down the equipment.

    Firmware Code RemarksUpdating HDD/UI data 08-944 HDD Version

    08-924 Version of UI data language 1 in HDD

    Updating System ROM 08-900 System firmware ROM version

    08-921 System firmware ROM internal program version

    Updating OS 08-920 FROM basic section software version

    Updating Engine ROM 08-903 Engine ROM version

    Updating Scanner ROM 08-905 Scanner ROM version

    Updating RADF ROM 08-907 RADF ROM version

    Updating Finisher ROM 08-908 Finisher ROM version

    08-911 Hole punch unit ROM version (MJ-6101 only)

    08-9945 Converter board ROM version

    Updating FAX ROM 08-915 FAX ROM version

  • 8

    2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455FIRMWARE UPDATING

    8 - 51

    8.5 When Firmware Updating FailsWhen the equipment was shut down during firmware updating or it could not be started after updating for some reason, perform firmware updating again following the procedure below.

    8.5.1 Procedure

    (1) Update System ROM of the system control PC board (SYS board) using the download jig (PWA-DWNLD-350-JIG2).Updating with the USB media becomes possible only after the System ROM (OS data) has been updated.See the updating procedure below for details.

    P.8-16 "8.2 Firmware Updating with PWA-DWNLD-350-JIG2"

    (2) Update Master Data, Engine ROM and Scanner ROM using the USB media.See the updating procedure below for details.

    P.8-5 "8.1 Firmware Updating with USB Media"

    (3) When the update with the USB media for Engine ROM and Scanner ROM failed, update these ROMs using the respective download jigs in the table below.

    Important: If the equipment cannot be started even when the above update has been performed, check that there is no damage to the SYS board, LGC board or SLG board. Replace them if necessary.

    Firmware Storage location Download jigEngine ROM Logic PC board

    (LGC board)PWA-DWNLD-350-JIG2

    P.8-22 "8.2.3 Engine ROM"

    Scanner ROM Scanning section control PC board(SLG board)

    K-PWA-DLM-320 P.8-25 "8.3.1 Scanner

    ROM"

  • e-STUDIO205L/255/305/355/455 2009 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING

    8 - 52

    8.5.2 Flow chart for correcting USB update failure

    [A] When the update of the System ROM (OS data) failed

    USB update failed

    Update completed

    Update download jig. (System ROM)

    Check ROM version.

    Update succeeded?

    Replace SYS board.

    Is ROM version correct?

    " 8.2.2 System ROM "

    " 8.4 Confirmation of the updated data "

    YES

    YES

    YES

    NO

    NO

    NO

    Failed twice or more? Update USB.

    Update USB.

    YES

    NO

    Failed twice or more?

  • 8

    2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455FIRMWARE UPDATING

    8 - 53

    [B] When the update of HDD program data / system firmware / UI data (master data) failed

    Check HDD harness connection.

    Replace HDD.

    YES

    YES

    YES

    YES

    NO

    NO

    NO

    NO

    USB update failed

    Failed twice or more? Update USB.

    Update USB.

    Update succeeded?

    Check HDD/ROM version.

    " 8.4 Confirmation of the updated data "

    Is HDD/ROM version correct?

    Update completed

    Update USB.

    Update succeeded?

    Replace SYS board.

    Update USB.

  • e-STUDIO205L/255/305/355/455 2009 TOSHIBA TEC CORPORATION All rights reservedFIRMWARE UPDATING

    8 - 54

    [C] When the update of Laser ROM / Engine ROM / PFC ROM failed / Scanner ROM failed

    Clear [Update Error Flags].

    Assist Mode : Turn the power ON with [3] + [CLEAR] + [ON/OFF]

    Clear flags. [1] -> [START]

    Replace target board.

    Check harness connection.

    SYS board SYS board

    " 8.2.3 Engine ROM "

    " 8.3.1 Scanner ROM "

    NO

    YES

    YES

    YES

    YES

    NO

    NO

    NO

    USB update failed

    Update USB.Failed twice or more?

    Update download jig.

    Update succeeded?

    Check ROM version.

    " 8.4 Confirmation of the updated data "

    Is ROM version correct?

    Update completed

    Failed twice or more?

    Update download jig.