ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray...

31
ERRECI S.r.l. PRESENTAZIONE TELEDYNE LEEMAN LABS

Transcript of ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray...

Page 1: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

ERRECI%S.r.l.%

PRESENTAZIONE%TELEDYNE%

LEEMAN%LABS%

Page 2: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

Azienda%con%competenze%mulAdisciplinari%composta%da%ricercatori,%

ingegneri%e%professionisA%dei%servizi%appassionaA%di%speGroscopia%

atomica.%La%missione%è%produrre%strumentazione%di%pregio%e%qualità%a%

livello%mondiale%nel%seGore%dell’analisi%elementare.%L’obieMvo%–%

realizzato%tramite%l'innovazione%conAnua,%la%dedizione,%e%il%costante%

rinnovamento%P%è%quello%di%alzare%costantemente%il%livello,%fornendo%a%

scienziaA%ed%analisA,%strumentazione%all'avanguardia%che%garanAsce%

risultaA%straordinari.%%

TELEDYNE%LEEMAN%LABS%ERRECI%È%LIETA%DI%ANNUNCIARE%CHE%È%IN%FASE%DI%DEFINIZIONE%IL%RAPPORTO%DI%DISTRIBUZIONE%PER%L’ITALIA%DELLA%LINEA%DI%STRUMENTAZIONE%TELEDYNE%LEEMAN%LABS,%NEI%PROSSIMI%MESI%SAREMO%

QUINDI%UFFICIALMENTE%I%DISTRIBUTORI%DELLA%LORO%LINEA%DI%PRODOTTI.%%

Page 3: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

LA%LINEA%STRUMENTALE%

INCLUDE%%

Page 4: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

SPETTROMETRO%ICPPOES%E%ICPPAES%

SPETTROMETRI%ICP:OES%E%ICP:AES%Prodigy%7%Simultaneo,%assiale,%radiale,%dual%view%(165P1100%nm),%detector%CMOS%Prodigy;%Simultaneo,%assiale,%radiale,%dual%view%(165P1100%nm)%Prodigy%XP%Simultaneo,%assiale,%radiale,%dual%view%(170P900%nm)%

Page 5: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

SPETTROMETRO%ICPPOES%E%ICPPAES%PRODIGY%7%

Rev .1.00 11/13/13

Prodigy 7 Instrument Specifications

Page 6: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

Simultaneo,%assiale,%radiale,%dual%view%

165P1100%nm%

DETECTOR%CMOS%Acquisizione%realmente%simultanea%

(FSA)%Full%Spectra%Access%raccolta%dell'intero%speGro%di%lunghezze%d'onda%in%una%sola%leGura%

PRODIGY%7%

Page 7: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

COMPLEMENTARY%METAL%OXIDE%SEMICONDUCTOR%%

%

PRODIGY%7%

DETECTOR%CMOS%%

Page 8: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

!  Ampio%detector%28X28%mm%

!  1840x1840%pixels%/%3,38%Milioni%di%pixels%

!  Dimensione%Pixel%15%µm%

!  40%volte%più%veloce%di%un%detector%L:PAD%

!  Metod i% r ap id i s s im i ,% può% l egge re% 256% lunghezze% d ’onda%contemporaneamente%

!  Copre%in%un'unica%le_ura%il%100%%del%campo%di%misura%165:1100%nm%

%

PRODIGY%7%

DETECTOR%CMOS%%

Page 9: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

PRODIGY%7%

DETECTOR%CMOS%%

•  Immagine%Full%Frame%dell’intero%spe_ro%da%165:1100%nm%•  Può%essere%raccolto%dopo%ogni%campione%

IMMAGINE%FULL%FRAME%

Page 10: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

PRODIGY%7%

PLASMA%

LETTURA%RADIALE,%ASSIALE%E/O%DUAL%VIEW%

Page 11: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

PRODIGY%7%

SOFTWARE%SALSA%

•  GESTIONE%COMPLETA%DELL’ICP%E%DEGLI%ACCESSORI%•  OTTIMIZZAZIONE%DEI%PARAMETRI%ANALITICI%PER%MIGLIORARE%LE%ANALISI%•  FSA%Full%Spectra%Access%PER%DETERMINARE%COMPONENTI%NON%PRESENTI%NEL%

METODO%INIZIALE%•  TRA%“Time%Resolved%Analysis”%

Page 12: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

SPETTROMETRO%ICPPOES%E%ICPPAES%PRODIGY%Prodigy

High Dispersion ICP

Page 13: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

Simultaneo,%assiale,%radiale,%dual%view%(165P1100%nm)%

DETECTOR%LPPAD%

Large%Programmable%Array%Detector%

PRODIGY%

Page 14: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

SPETTROMETRO%ICPPOES%E%ICPPAES%PRODIGY%XP%

Page 15: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

Simultaneo,%assiale,%radiale,%dual%view%(170P900%nm)%

DETECTOR%CPPAD%

Composite%Programmable%Array%Detector%

IDEALE%RAPPORTO%QUALITÀ/PREZZO%

PRODIGY%XP%

Page 16: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

PERCHÉ%SCEGLIERE%PRODIGY%

Page 17: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

CARATTERISTICHE%PECULIARI%DELLA%STRUMENTAZIONE%TELEDYNE%

DETECTOR%!  AUMENTO% DELLA% PRODUTTIVITÀ% DEL% LABORATORIO,% IL% DESIGN% SIMULTANEO% CONSENTE% LA%

LETTURE%IMMEDIATA%DI%MULTIPLE%LUNGHEZZE,%RIDUCENDO%I%TEMPI%DI%ANALISI%

!  MASSIMA% FLESSIBILITÀ% NELLA% MESSA% A% PUNTO% DEI% METODI,% SI% POSSONO% AGGIUNGERE% O%MODIFICARE%GLI%ELEMENTI%DI%INTERESSE%DIRETTAMENTE%DAL%SOFTWARE%

DESIGN%!  STRUMENTAZIONE%DA%BANCO%COMPATTA,%GARANTISCE%ECCELLENTI%PRESTAZIONI%ANALITICHE%

IN%POCO%SPAZIO%

CONFIGURAZIONI%!  CONFIGURAZIONI% DISPONIBILI;% ASSIALE,% RADIALE% O% DUALPVIEW% (ASSIALE/RADIALE)% PER%

COPRIRE%TUTTE%LE%ESIGENZE%ANALITICHE%

Page 18: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

CARATTERISTICHE%PECULIARI%DELLA%STRUMENTAZIONE%TELEDYNE%

PLASMA%!  IMMAGINE% DEL% PLASMA% STABILIZZATA% PER% UN% VELOCE%

RISCALDAMENTO%DELLO% SPETTROMETRO% E% PER%GARANTIRE% ANALISI%STABILI%NEL%LUNGO%PERIODO.%

Simultaneous ICP with State-of-the-art Array Detection

• Improves laboratory productivity because simultaneousdesign permits measurement of multiple wavelengths atthe same time without extending the sample analysis time.

• Advanced array detector permits operator to add orchange the elements of interest directly from the instrument software.

The following benefits are provided by Prodigy’sTechnically Advanced Optical Spectrometer Design

Compact High Resolution Benchtop Instrument

• Prodigy provides superior analytical performance without taking up more of your valuable laboratory space.

Axial, Radial or Dual View Configurations to suit all of today’s applications

Image Stabilized ICP Source for fast warm-up and superior long-term stability

High Resolution Spectrometer

• Prodigy’s superioroptical resolution of0.0075 nm results infewer spectral interferences,better accuracy and fewer QC failures.

• For the high performance applications,Prodigy also offers an optional user selectableinput slit allowing optical resolutions as high as 0.005 nmto be selected. This feature further improves performancein spectrally complex sample types.

Superior Wavelength Coverage • Prodigy’s optical design allows the user to access all wavelengths

from 160 to 900 nm. This opens up previously inaccessiblewavelengths for many elements giving the analyst the abilityto achieve superior detection limits for some elements.

Lower stray light

• Prodigy’s long focal length optical spectrometer (800 mm)results in lower stray light and superior performance in complex sample matrices. Stray light is inversely proportional to the square of the focal length. BecauseProdigy’s focal length is 2 times greater than most competing systems it has 4 times lower the stray light.

14 Reasons to Choose theProdigy High Dispersion ICP

1

6

72

3

4

5

Designed for Superior Performance,Productivity and Reliability

Why choose a Prodigy ICP? For its: State of the Art Array Detection

Compact Benchtop Design

Axial, Radial or Dual View Capability

Long-term Stability

High Resolution

Superior Wavelength Coverage

Wide Dynamic Range

Superior Productiviy

%

OTTICA%AD%ALTA%RISOLUZIONE%!  RISOLUZIONE% OTTICA% DI% 0,0075% nm% PER% GARANTIRE% IL% MINOR%

NUMERO%DI% INTERFERENZE%SPETTRALI,%UNA%MAGGIORE%PRECISIONE%E%MENO%ERRORI%IN%QC.%

!  PER%LE%APPLICAZIONI%AD%ALTE%PRESTAZIONI,%PRODIGY%OFFRE%ANCHE%LA% POSSIBILITÀ% ALL’OPERATORE% DI% SELEZIONARE% (OPZIONALE)% LA%

FENDITURA% FINO% A% RISOLUZIONI% DI% 0,005% nm.% QUESTA% FUNZIONE%MIGLIORA%ULTERIORMENTE%LE%PRESTAZIONI%SU%MATRICI%COMPLESSE.%

Page 19: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

CARATTERISTICHE%PECULIARI%DELLA%STRUMENTAZIONE%TELEDYNE%

MONOCROMATORE%IL%DESIGN%OTTICO%DI%PRODIGY%PERMETTE%ALL'UTENTE%DI%ACCEDERE%A%TUTTE%LE%LUNGHEZZE%

D'ONDA%TRA%160P1100.%QUESTO%CONSENTE%LETTURE%A%LUNGHEZZE%D'ONDA%PRECEDENTEMENTE%INACCESSIBILI,DANDO%ALL'ANALISTA%LA%CAPACITÀ%DI%RAGGIUNGERE%LIMITI%DI%RILEVAZIONE%

SUPERIORI%PER%MOLTI%ELEMENTI%

LUCE%DIFFUSA%

!  LUCE%DIFFUSA%MOLTO%BASSA,%LA%FOCALE%OTTICA%DA%800%mm%(la% luce%diffusa%è% inversamente%

proporzionale%al%quadrato%della%lunghezza%focale)%CONSENTE%DI%OTTENERE%UNA%LUCE%DIFFUSA%BASSISSIMA,%GARANTENDO%PRESTAZIONE%ECCELLENTI%ANCHE%IN%MATRICI%COMPLESSE%

!  LA% LUNGHEZZA% FOCALE% DEL% PRODOGY% È% DUE% VOLTE% MAGGIORE% RISPETTO% ALLA% MAGGIOR%PARTE%DEI%CONCORRENTI,%LA%LUCE%DIFFUSA%È%PERTANTO%4%VOLTE%INFERIORE%

Page 20: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

CARATTERISTICHE%PECULIARI%DELLA%STRUMENTAZIONE%TELEDYNE%

RIPRODUCIBILITÀ%ECCELLENTE%RIPRODCIBILITÀ%E%STABILITÀ%NEL%LUNGO%PERIODO,%MIGLIORE%DEL%2%%RSD/PER%GIORNO.%UTILE%AD%OTTENERE%MIGLIORI%RISULTATI%IN%TERMINI%DI%PRODUTTIVITÀ%E%NEL%QC.%

%

%

%

%

%

%

RISULTATI%OTTENUTI%GRAZIE%AL%NUOVO%LPPAD%DETECTOR%(LargePProgrammable%Array%Detector)%

Superior long-term stability

• Prodigy typically provides long-term stability better than2% RSD per day. This translates into superior productivity from less drift and fewer QC failures.

The following benefits are a result of Prodigys’ Innovativenew State-of-the-art Large Format Programmable ArrayDetector (L-PAD)

Large format detector (27mm by 27 mm)

• Prodigy’s L-PAD allows us to take advantage of the high dispersion spectrometer design (meaning the distancebetween adjacent wavelengths is greater) yielding superiorresolution and few interferences). Most competing ICPs use a detector that is 1/4 the size of that in Prodigy.

Wide Linear dynamic range

• Prodigy’s advanced L-PAD detector incorporates large fullwell capacity and non destructive readout capability whichgives the user the advantage of superior linear dynamic range; in excess of 6 orders of magnitude. (Many array based systems have a dynamic range of only 3 to 4 orders of magnitude necessitating sample dilutions and/or reruns.)

Programmable Access Integration and the Contiguous PixelStructure of Prodigy’s L-PAD Allows Direct Readout ofEither the Detector Regions of Interest or the EntireSpectrum all with High Speed Data Transmission

• With Prodigy’s Programmable Integration Capability, L-PADallows you to capture the entire spectrum or only the spectral regions you require, or both; the choice is yours. For applications requiring time resolved data acquisition, such as with element specific chromatography, L-PAD is a distinct advantage.

Advance Simultaneous Data Collection Technology

• Prodigy is the only array detector based ICP that provides truesimultaneous data collection for all elements, all backgroundpoint, all internal standards, etc. This capability provideslower detection limits and superior measurement precision,especially where elemental ratio measurements are of interest.

• Simultaneous Background Correction provide LowerDetection Limits

• Simultaneous measurement of internal standardsand IECs provide improved accuracy

Superior Productivity for All Applications

• Prodigy’s image stabilized ICP source and high resolutionoptical system provide superior analytical reliability (fewerinterferences, less drift, etc.) which means you will experiencefewer QC failures, fewer reruns and superior productivity.

All Leeman ICP and Hg products are Made in America

6 Wentworth DriveHudson, NH 03051 U.S.A.Tel: 603.886.8400Fax: 603.886.9141Email: [email protected]

9

10

11

12

13

14

8

Don’t Settle for just any ICP.Go with Prodigy.

Page 21: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

CARATTERISTICHE%PECULIARI%DELLA%STRUMENTAZIONE%TELEDYNE%

DETECTOR%!  IL%DETECTOR%LPPAD%DA%27X27%mm%PERMETTE%DI%OTTENERE%GROSSI%VANTAGGI%DALL’OTTICA%ED%

UNA% RISOLUZIONE% SUPERIORE% IN% TEMRINI% DI% LUNGHEZZE% D’ONDA% (IMPORTANTE% PER%MINIMIZZARE%LE%INTERFERENZE).%

%

%

%

%

%

LA%MAGGIOR%PARTE%DEI%CONCORRENTI%HA%DETECTOR%DI%DIMENSIONI%MOLTO%RIDOTTE%RISPETTO%AL%PRODIGY%(CIRCA%1/4)%

Superior long-term stability

• Prodigy typically provides long-term stability better than2% RSD per day. This translates into superior productivity from less drift and fewer QC failures.

The following benefits are a result of Prodigys’ Innovativenew State-of-the-art Large Format Programmable ArrayDetector (L-PAD)

Large format detector (27mm by 27 mm)

• Prodigy’s L-PAD allows us to take advantage of the high dispersion spectrometer design (meaning the distancebetween adjacent wavelengths is greater) yielding superiorresolution and few interferences). Most competing ICPs use a detector that is 1/4 the size of that in Prodigy.

Wide Linear dynamic range

• Prodigy’s advanced L-PAD detector incorporates large fullwell capacity and non destructive readout capability whichgives the user the advantage of superior linear dynamic range; in excess of 6 orders of magnitude. (Many array based systems have a dynamic range of only 3 to 4 orders of magnitude necessitating sample dilutions and/or reruns.)

Programmable Access Integration and the Contiguous PixelStructure of Prodigy’s L-PAD Allows Direct Readout ofEither the Detector Regions of Interest or the EntireSpectrum all with High Speed Data Transmission

• With Prodigy’s Programmable Integration Capability, L-PADallows you to capture the entire spectrum or only the spectral regions you require, or both; the choice is yours. For applications requiring time resolved data acquisition, such as with element specific chromatography, L-PAD is a distinct advantage.

Advance Simultaneous Data Collection Technology

• Prodigy is the only array detector based ICP that provides truesimultaneous data collection for all elements, all backgroundpoint, all internal standards, etc. This capability provideslower detection limits and superior measurement precision,especially where elemental ratio measurements are of interest.

• Simultaneous Background Correction provide LowerDetection Limits

• Simultaneous measurement of internal standardsand IECs provide improved accuracy

Superior Productivity for All Applications

• Prodigy’s image stabilized ICP source and high resolutionoptical system provide superior analytical reliability (fewerinterferences, less drift, etc.) which means you will experiencefewer QC failures, fewer reruns and superior productivity.

All Leeman ICP and Hg products are Made in America

6 Wentworth DriveHudson, NH 03051 U.S.A.Tel: 603.886.8400Fax: 603.886.9141Email: [email protected]

9

10

11

12

13

14

8

Don’t Settle for just any ICP.Go with Prodigy.

Page 22: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

CARATTERISTICHE%PECULIARI%DELLA%STRUMENTAZIONE%TELEDYNE%

DETECTOR%!  IL% DETECTOR% LPPAD% CONSENTE% LETTURE% NONPDISTRUTTIVE% CON% UN% ECCELLENTE% RANGE%

DINAMICO,% SUPERIORE% A% 6% ORDINI% DI% GRANDEZZA% (MOLTI% SISTEMI% BASATI% SI% DIODE% ARRAY%HANNO%RANGE%DINAMICI%DI%SOLO%3/4%ORDINI%DI%GRANDEZZA).%

!  LA%STRUTTURA%DEL%DETECTOR%LPPAD%CON%ACCESSO%PROGRAMMABILE%PERMETTE%LA%LETTURA%DIRETTA%DI% TUTTE% LE% REGIONI%DI% INTERESSE%DELL’INTERO% SPETTRO%DI% EMISSIONE% CON%UNA%TRASMISSIONE%DEI%DATI%AD%ELEVATA%VELOCITÀ%

!  LA% CAPACITÀ% DI% PRODIGY% DI% PROGRAMMARE% L’INTEGRAZIONE% DEL% SEGNALE,% PERMETTE% DI%CATTURARE%L'INTERO%SPETTRO%O%SOLO%LE%REGIONI%SPETTRALI%RICHIESTE,%OPPURE%ENTRAMBE,%LA%SCELTA%È%DELL’OPERATORE.%PER%APPLICAZIONI%CHE%RICHIEDONO%PIÙ%LETTURE%NEL%TEMPO,%AD%ESEMPIO%UNA%CROMATOGRAFIA,%IL%DETECTOR%LPPAD%È%UN%VANTAGGIO.%

Page 23: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

CARATTERISTICHE%PECULIARI%DELLA%STRUMENTAZIONE%TELEDYNE%

ACQUISIZIONE%SIMULTANEA%AVANZATA%!  IL% DETECTOR% LPPAD% CONSENTE% LETTURE% NONPDISTRUTTIVE% CON% UN% ECCELLENTE% RANGE%

DINAMICO,% SUPERIORE% A% 6% ORDINI% DI% GRANDEZZA% (MOLTI% SISTEMI% BASATI% SI% DIODE% ARRAY%HANNO%RANGE%DINAMICI%DI%SOLO%3/4%ORDINI%DI%GRANDEZZA).%

!  PRODIGY% HA% L’UNICO% RIVELATORE% DIODE% ARRAY% PER% ICP% CHE% CONSENTE% UNA% LETTURA%REALMENTE% SIMULTANEA% DEI% DATI% DI% TUTTI% GLI% ELEMENTI,% DEL% BIANCO% (BACKGROUND),%DELLO% STANDARD% INTERNO,% ECC.% QUESTA% TECNOLOGIA% PERMETTE% DI% RAGGIUNGERE%

SUPERIORI% SOGLIE% DI% SENSIBILITÀ% E% PRECISIONE,% SOPRATTUTTO% DOVE% È% IMPORTANTE% IL%RAPPORTO%TRA%ELEMENTI.%

!  CORREZIONE%SIMULTANEA%DEL%RUMORE%DI%FONDO%PER%LIMITI%DI%SENSIBILITÀ%SUPERIORI%

!  LETTURA% SIMULTANEA% DELLO% STANDARD% INTERNO% E% IECs% (Inter% Element% CorrecAon)% PER%MAGGIORE%ACCURATEZZA%

Page 24: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

CARATTERISTICHE%PECULIARI%DELLA%STRUMENTAZIONE%TELEDYNE%

SUPERIORE%PRODUTTIVITÀ%!  L’IMMAGINE% DEL% PLASMA% STABILIZZATA% COMBINATA% ALL’OTTICA% AD% ELEVATA% RISOLUZIONE%

PERMETTONO%UNA%RIPRODUCIBILITÀ%ANALITICA%SUPERIORE%(MINORI%INTERFERENZE,%MINORE%DERIVA,% ECC.)% IL% CHE% SIGNIFICA% MIGLIORARE% I% RISULTATI% IN% QC% ED% AUMENTARE% LA%PRODUTTIVITÀ%

!  STRUMENTAZIONE%COSTRUITA%NEGLI%STATI%UNITI%

Page 25: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

REFERENZE%PresenAamo,%tra%le%svariate%aziende%di%cui%siamo%fornitori%per%la%

strumentazione%scienAfica,%alcune%tra%le%più%significaAve%%

Page 26: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

REFERENZE%SIGNIFICATIVE%

• Istituto Giannina Gaslini Ospedale Pediatrico Largo Gaslini, 5 – Genova • Azienda Sanitaria Ospedaliera O.I.R.M. Sant’ANNA di Torino Piazza Polonia 94 – Torino • Azienda Spedali Civili di Brescia Piazzale Spedali Civili, 1; 25123 – Brescia • Università degli Studi di Milano - DISTAM Via Caloria, 2; 20133 – Milano • ISTITUTO SPERIMENTALI OLII E GRASSI DI MILANO Via Giuseppe Colombo, 6– Milano • I.C.P. Istituti Clinici di Perfezionamento Via Daverio, 6; 20122 – SPESSA PO’ (PV) • OSPEDALE PEDIATRICO BAMBINO GESU' P.zza Onofrio, 4; 00165 – ROMA • AGRIBRANDS EUROPE ITALIA S.p.A. VIA PAVIA, 4; 27010 – SPESSA PO’ (PV) • ASSOCIAZIONE Oasi Maria SS. - IRCCS Via Conte Ruggero 73; 94018 – TROINA (EN) • Azienda Ospedaliera Bologna - POLICLINICO SANT'ORSOLA Via Alberoni, 15; 40138 – BOLOGNA • AZIENDA OSPEDALIERA MEYER Via Luca Giordano, 7/M; 50132 – FIRENZE • CHIRON S.p.A. Via Fiorentina, 1; 53100 – SIENA • OSPEDALE SAN PAOLO DI MILANO - CLINICA PEDIATRICA Via A. Di Rudini, 8; 20142 – MILANO • SECONDA UNIVERSITA' DI NAPOLI - Dip.Scienze della Vita Via Vivaldi, 43; 81100 – CASERTA • Policlinico-università Degli Studi Di Napoli FEDERICO II Via Sergio Pansini, 5; 80131 – NAPOLI • UNIVERSITA' DEGLI STUDI DI CATANIA - Settore Provveditorato Via S.Sofia, 78; 95123 – CATANIA%

Page 27: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

REFERENZE%SIGNIFICATIVE%

• Ministero delle Politiche Agricole e Forestali Dip. dell’Ispettorato Centrale della Tutela della Qualità e Repressione Frodi dei Prodotti Agro-Alimentari Direzione Generale della Vigilanza per la Qualità e la Tutela del Consumatore – Vico III Via Quintino Sella, 42 - 00187 – ROMA • Ministero delle Politiche Agricole e Forestali Dip. dell’Ispettorato Centrale della Tutela della Qualità e Repressione Frodi dei Prodotti Agro-Alimentari Laboratorio di Perugia Via della Madonna Alta, 138/c-d - 06128 – PERUGIA • OSPEDALE DI FANO-Neuropsichiatria Infantile Via Vittorio Veneto, 2 – 61032 – FANO • CEINGE Biotecnologie Avanzate S.carl Via Comunale Margherita – 80131 NAPOLI • UNIVERSITÀ DEGLI STUDI DEL MOLISE DIPARTIMENTO DI STAAM - Via De Sanctis snc – 86100 CAMPOBASSO • OSPEDALE PEDIATRICO GIOVANNI XXIII DI BARI Via Amendola - 70126 BARI • OSPEDALE CIVILE PUGLIESE – CLINICA PEDIATRICA Viale Pio X – 88100 – CATANZARO • Università Degli Studi Di Bari – Dip. di Protezione delle Piante e Microbiologia Applicata Via G. Amendola 165/a - 70126 BARI • AZIENDA SANITARIA LOCALE NAPOLI 1 Via F. Baracca, 4; 80134 – NAPOLI • Tielle Diagnostyc S.r.l. - Via Tagliamento 64 – Adrano (CT) • ISTITUTO B. RAMAZZINI S.r.l. - Via Dottor Consoli – CATANIA • RICERCHE CLINICHE PROF. MANFREDO FANFANI S.a.s. - Piazza della Indipendenza, 18/b – FIRENZE

Page 28: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

SERVIZI%OFFERTI:%

ASSISTENZA%TECNICA,%SERVICE,%NOLEGGI%

%!  La%qualità%delle%prestazioni%che%siamo%in%grado%di%proporre%e%arricchita%dal%servizio%di%assistenza%tecnica%in%grado%di%realizzare%cerAficazioni,%manutenzioni%programmate%ed%

intervenA%su%richiesta,%oltre%alla%messa%a%punto%delle%metodologie%analiAche.%

!  Per% garanAre% una% proficua% collaborazione% ERRECI% meGe% a% disposizione% dei% propri%

partner%il%materiale%tecnico%ed%informaAvo%necessario%ad%una%correGa%informazione%

presso% i% clienA,% garanAsce% periodici% corsi% di% formazione% sulle% tecniche% e% la%strumentazione% proposta,% garanAamo% inoltre% un’assistenza% commerciale% direGa% e%

personalizzata,%che%comprende%visite%presso%i%clienA%e%supporto%telefonico.%

!  Siamo%disponibili%per%qualsiasi%chiarimento%telefonico%o%con%la%visita,%senza%impegno,%

dei%nostri%responsabili%commerciali.%

Page 29: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

Siamo%in%grado%proporre%materiale%consumabile%ed%accessori%per%tuGe%le%tecniche%da%noi%traGaGe:%

Page 30: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

PAROLE% CHIAVE:% SpeGrometro% ICPPOES/ICPPAES,% Analisi% dei% metalli,% analisi%

ambientali,% acque,% acque% reflue,% terreni,% analisi% cliniche,% autocampionatore,%

Simultaneo,% Assiale,% radiale,% DualPView,% kit% degli% idruri,% analizzatore% di%

mercurio,%quantometri%

POTENZIALI%CLIENTI%!  Laboratori%analisi%conto%terzi,%in%ambito%ambientale,%clinico,%alimentare,%farmaceuAco,%industria%

!  Centri%di%ricerca,%CNR,%CRA,%IsAtuA%zooprofilaMci,%Repressione%Frodi,%ministeri%

!  Università%(tuM%i%diparAmenA%scienAfici)%

!  Industria%dei%metalli,%leghe,%metalli%preziosi,%recupero%metalli%

!  EnA%e%consorzi%di%tutela%delle%acque,%ARPA,%ASL%

!  Industria%farmaceuAca%

!  Industria%alimentare,%produGori%di%succhi%di%fruGa,%laGe%e%derivaA,%vino,%ecc.%

!  Aziende%Ospedaliere,%Ospedali%pediatrici,%Ospedali%universitari,%centri%di%riferimento%screening%neonatale%

Page 31: ERRECI% · • Prodigy’s long focal length optical spectrometer (800 mm) results in lower stray light and superior performance in complex sample matrices. Stray light is inversely

ERRECI%S.r.l.%Via%delle%Robinie,%21%

20090%–%OPERA%(MI)%

T.%02/57600456%

Fax%02/57600082%

ePmail:%[email protected]%

STRUMENTAZIONE SCIENTIFICA E ANALITICA

VENDITA E ASSISTENZA TECNICA

www.erreci-tech.it

ERRECI