equipmentlist RNC450

42
7/27/2019 equipmentlist RNC450 http://slidepdf.com/reader/full/equipmentlist-rnc450 1/42 Nokia Siemens Networks WCDMA RAN, Rel. RU20, Operating Documentation, Issue 06 Equipment Lists for RNC450 DN0639624 Issue 02C  Confidential

Transcript of equipmentlist RNC450

Page 1: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 1/42

Nokia Siemens Networks

WCDMA RAN, Rel. RU20,

Operating Documentation,Issue 06

Equipment Lists for RNC450

DN0639624

Issue 02C 

Confidential

Page 2: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 2/42

2 DN0639624

Issue 02C

Equipment Lists for RNC450

Id:0900d8058086e418

Confidential

The information in this document is subject to change without notice and describes only the

product defined in the introduction of this documentation. This documentation is intended for the

use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted

in any form or means without the prior written permission of Nokia Siemens Networks. The

documentation has been prepared to be used by professional and properly trained personnel,

and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes

customer comments as part of the process of continuous development and improvement of the

documentation.

The information or statements given in this documentation concerning the suitability, capacity,

or performance of the mentioned hardware or software products are given "as is" and all liability

arising in connection with such hardware or software products shall be defined conclusively and

finally in a separate agreement between Nokia Siemens Networks and the customer. However,

Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions

contained in the document are adequate and free of material errors and omissions. Nokia

Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which

may not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO

EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-

TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-

RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED

TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY

OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION

IN IT.

This documentation and the product it describes are considered protected by copyrights and

other intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark

of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2011. All rights reserved

f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources

of danger.

Only trained and qualified personnel may install, operate, maintain or otherwise handle

this product and only after having carefully read the safety information applicable to this

product.

The safety information is provided in the Safety Information section in the “Legal, Safety

and Environmental Information” part of this document or documentation set.

The same text in German:

f Wichtiger Hinweis zur ProduktsicherheitVon diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder 

andere Gefahrenquellen ausgehen.

Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch

geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-

anforderungen erfolgen.

Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal,

Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentations-

satzes.

Page 3: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 3/42

DN0639624 3

Equipment Lists for RNC450

Id:0900d8058086e418

Confidential

Table of contentsThis document has 42 pages.

Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1 About Equipment l ists for RNC450. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

1.1 Related documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

1.2 Notations used in equipment lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2 RNAC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

2.1 RNAC cabinet mechanics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

2.1.1 Subracks, fan trays, and cable supporting shelves to the front . . . . . . . 11

2.1.2 Subracks for back interfaces, panels, and cable supporting shelves to the

rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

2.1.3 Back interface units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

2.1.4 Equipment kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

2.2 RNAC functional units and plug-in units . . . . . . . . . . . . . . . . . . . . . . . . 16

2.3 RNAC cabinet stickers and marking strips. . . . . . . . . . . . . . . . . . . . . . . 20

2.3.1 Marking strips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

2.3.2 Stickers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

3 RNBC cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

3.1 RNBC cabinet mechanics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

3.1.1 Subracks, fan trays, and cable supporting shelves to the front . . . . . . . 22

3.1.2 Subracks for back interfaces and cable supporting shelves to the rear. 22

3.1.3 Equipment kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

3.1.4 Grounding set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233.2 RNBC functional units and plug-in units . . . . . . . . . . . . . . . . . . . . . . . . 25

3.3 RNBC cabinet stickers and marking strips. . . . . . . . . . . . . . . . . . . . . . . 29

3.3.1 Marking strips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

3.3.2 Stickers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

4 NIS1P, NIS1 and NIP1 equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . 30

4.1 NIP1 equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

4.2 NIS1P and NIS1 equipping rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

4.2.1 Equipping NIS1P and NIS1 units to RNC450 step 1 . . . . . . . . . . . . . . . 31

4.2.2 Equipping NIS1P and NIS1 units to RNC450 step 2 . . . . . . . . . . . . . . . 33

4.2.3 Equipping NIS1P and NIS1 units to RNC450 step 3 . . . . . . . . . . . . . . . 35

5 Cabinet stickers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

Page 4: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 4/42

4 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e418

Confidential

List of figuresFigure 1 Notations used in the equipment lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Figure 2 Positions of CPSY-A, CPSY-B, and CPAL-A panels . . . . . . . . . . . . . . . 13

Figure 3 BIE1T and BIE1C equipping principle with SRBI-C . . . . . . . . . . . . . . . . 14

Figure 4 Functional units of the RNAC cabinet. . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Figure 5 Grounding between RNAC and RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Figure 6 Functional units of the RNBC cabinet. . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Figure 7 NIS1P, NIS1 and NIP1 equipping positions inRNC450 step 1 . . . . . . . . 31

Figure 8 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 2 . . . . . . . 33

Figure 9 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 3 . . . . . . . 35

Figure 10 NIS1 1 equipping restriction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Figure 11 NIS1 3 equipping restriction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

Figure 12 IPA2800 cabinet; note that front and back sides are identical . . . . . . . . 39

Figure 13 IPA2800 cabinet stickers; the stickers in the figure are attached to all cab-inets except Network Element Name stickers and Marking strips . . . . . 40

Figure 14 Stickers already attached on delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Figure 15 Product collection and disposal within the European Union . . . . . . . . . . 42

Page 5: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 5/42

DN0639624 5

Equipment Lists for RNC450

Id:0900d8058086e418

Confidential

List of tablesTable 1 RNAC cabinet mechanics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Table 2 Subracks and fan trays to the front for the RNAC . . . . . . . . . . . . . . . . . 11

Table 3 Subracks for back interfaces, panels, and cable supporting shelves for the

RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Table 4 Back interface units of the RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Table 5 Equipment kit EQIK216 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Table 6 Functional units, plug-in units, and memory modules of the RNAC . . . 17

Table 7 Marking strips for the RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Table 8 Stickers for the RNAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Table 9 RNBC cabinet mechanics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Table 10 Subracks and fan trays to the front for the RNBC . . . . . . . . . . . . . . . . . 22

Table 11 Subracks for back interfaces and cable supporting shelves for RNBC . 22

Table 12 Equipment kit EQIS216 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Table 13 Grounding sets for RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Table 14 Functional units and plug-in units of the RNBC . . . . . . . . . . . . . . . . . . 26

Table 15 Marking strips for the RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Table 16 Stickers for the RNBC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Table 17 STM-1/OC-3 ATM interfaces in RNC450 . . . . . . . . . . . . . . . . . . . . . . . 30

Table 18 Number of units in mixed configurations of 2N redundant and non-redun-

dant units in RNC450 step 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Table 19 Number of units in mixed configurations of 2N redundant and non-redun-

dant units in RNC450 step 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Table 20 Number of units in mixed configurations of 2N redundant and non-redun-

dant units in RNC450 step 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Page 6: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 6/42

6 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e418

Confidential

Page 7: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 7/42

DN0639624 7

Equipment Lists for RNC450 Summary of changes

Id:0900d8058086e3fe

Confidential

Summary of changesChanges between document issues are cumulative. Therefore, the latest document

issue contains all changes made to previous issues.

Change between Issue 2-2 ( 2010-09-30, WCDMA RAN RU20) and 02C ( 2011-04-13

WCDMA RNA RU20)

RNAC cabinet (2)

 –  NEMU related infromation is removed.

Changes for issue 2-2

Section NIS1P, NIS1 and NIP1 equipping rules updated: equipping rules and restric-

tions are described for each RNC450 capacity step separately.

Changes for issue 2-1

 A new CPU variant CCP18-C is taken into use. CCP18-A is still used with OMU,

because the USB port is needed for backup purposes.

Page 8: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 8/42

8 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e3ff 

Confidential

 About Equipment lists for RNC450

1 About Equipment lists for RNC450Equipment lists for RNC450 provides a list of cabinet mechanics, subracks, and plug-in

units installed in the RNAC and RNBC cabinets for RNC450. Sections RNAC cabinet  

and RNBC cabinet include the physical positions of the hardware items inside the cab-

inets.

RNC450 features three capacity steps:

• RNC450 capacity step 150 = RNC450/150 (RNAC)

• RNC450 capacity step 300 = RNC450/300 (RNBC Sr 1–2)

• RNC450 capacity step 450 = RNC450/450 (RNBC Sr 3–4)

1.1 Related documents

Cable Lists

Detailed information on cabling and individual cables can be found in Cable Lists for 

RNC450.

Engineering Description

Basic information on, for example, RNC installation planning can be found in Engineer-

ing for Radio Network Controller (RNC).

Installation Manual

Detailed information on the installation of RNC hardware, see Installing the MGW and 

RNC.

Cabinet Interfaces and CablingDetailed information on cabinet interfaces and cabling can be found in Cabinet Inter-

faces and External Cables of MGW and RNC.

1.2 Notations used in equipment lists

The equipment lists contain the columns shown in the figure below, with their contents

described in the list which follows.

Page 9: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 9/42

DN0639624 9

Equipment Lists for RNC450 About Equipment lists for RNC450

Id:0900d8058086e3ff 

Confidential

Figure 1 Notations used in the equipment l ists

The positions are presented in the form of a table. The figure shows only one table type,

but tables can have the following columns:

• Side indicates the side on which the unit in question is equipped. (F = Front, B =

Back)

• Mounting hole no. indicates the number of the mounting hole used for the installation

of the particular unit.

• Subrack indicates the subrack position of a specific unit.

• Position shows the coordinates inside the rack and the number of the slot in the car-

tridge.

• ID (Identification) shows the identification code of the cabinet, cartridge, plug-in unit,

or accessory.

•Name shows the abbreviated name of the hardware product for the identificationcode in the previous column.

IPA2800 RNC / MGW cabinet,front view

DN05158674

1 2 3 4 5 6 7 8 9 10 11 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9

38

SUBRACK 3front view

Plug-in unit position number 

1

SUBRACK 1

SUBRACK 2

SUBRACK 3

SUBRACK 4

Position ID Name FU Notes

F01 C105546 CDSP-C DMCU 4

F02 C105546 CDSP-C DMCU 5

F03 C109093 ICSU 4

1

Subrack 3

CCP18-A Mounted

2GB memoryincluded

Page 10: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 10/42

10 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e3ff 

Confidential

 About Equipment lists for RNC450

• PIU indicates the name of the plug-in unit in question.

• FU (Functional Unit) shows the name and index number of the functional unit

equipped into the cartridge in this particular position.

• Use shows the name and number of the functional unit, which contains the plug-inunits listed below and equipped in this cartridge position.

• Notes column includes additional information.

When two or more different hardware products can be equipped in the same position,

the identification code and name of each type is given.

Page 11: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 11/42

DN0639624 11

Equipment Lists for RNC450 RNAC cabinet

Id:0900d8058086e400

Confidential

2 RNAC cabinetThis section lists all the equipment mechanics for the RNAC cabinet.

2.1 RNAC cabinet mechanics

2.1.1 Subracks, fan trays, and cable supporting shelves to the front

Equipping Side Mounting

hole no.

ID Name Use

C109740 EC216 Cabinet

F C109742 DR216 Door right

F C109743 DL216 Door left

B C109742 DR216 Door right

B C109743 DL216 Door left

F C110052 CPD120-A Power distribution

and fuse unit

F C110052 CPD120-A Power distribution

and fuse unit

F C110505 CAIND-A Cabinet Alarm indi-

cator 

C110076 SCP216 Side cover plate

C110076 SCP216 Side cover plate

Table 1 RNAC cabinet mechanics

Side Mounting hole

no.

ID Name Use

F 53 C109979 SRA3 Subrack

F 49 C109730 FTRA-B Fan tray

F 37 C109979 SRA3 Subrack

F 33 C109730 FTRA-B Fan tray

F 21 C109979 SRA3 SubrackF 17 C109730 FTRA-B Fan tray

F 5 C109979 SRA3 Subrack

F 1 C109730 FTRA-B Fan tray

Table 2  Subracks and fan trays to the front for the RNAC

Page 12: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 12/42

12 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e400

Confidential

RNAC cabinet

2.1.2 Subracks for back interfaces, panels, and cable supporting shelves

to the rear 

Side Mountinghole no./

Position

ID Name Use Notes

B 53 C110568 SRBI-C Subrack for back inter-

faces

B 50 C110730 CS216-A Cable supporting shelf  

B 50.01 C110551 CPSY-A Connector panel for syn-

chronisation

B 50.10 C110747 CPSY-B Connector panel for syn-

chronisation

B 37 C110568 SRBI-C Subrack for back inter-

faces

B 35 C110730 CS216-A Cable supporting shelf  

B 35.01 C110487 CPAL-A Connector panel for  

alarms

B 21 C105864 CS186-B Cable supporting shelf  

B 21 C110568 SRBI-C Subrack for back inter-

faces

B 5 C110568 SRBI-C Subrack for back inter-

faces

B 1 C105864 CS186-B Cable supporting shelf  

Table 3 Subracks for back interfaces, panels, and cable supporting shelves for the RNAC

Page 13: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 13/42

DN0639624 13

Equipment Lists for RNC450 RNAC cabinet

Id:0900d8058086e400

Confidential

Figure 2  Positions of CPSY-A, CPSY-B, and CPAL-A panels

2.1.3 Back interface units

BIE1T and BIE1C are optional back interface units for RNAC. They are used with NIP1

0.

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

38

CPSY-A

CPAL-A

CPSY-B

DN05160803

Page 14: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 14/42

14 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e400

Confidential

RNAC cabinet

Figure 3 BIE1T and BIE1C equipping principle with SRBI-C

Subrack Position ID PIU Name

3.0B 15 C103060 BIE1T Back interface unit

for E1, T1 and JT1

C103030 BIE1C Back Interface unit

for E1

Table 4 Back interface units of the RNAC

SMB connector Single or multicoaxial cable

RJ-45 connector Multicable

BIE1T

SRBI-C

NIP1

DN70200648BIE1C

SRBI-C

NIP1

Page 15: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 15/42

DN0639624 15

Equipment Lists for RNC450 RNAC cabinet

Id:0900d8058086e400

Confidential

2.1.4 Equipment kits

The EQIK216 equipment kit contains the following items:

• washers

• static control wrist strap

• screws

• pink minigrip bags

• locking pegs

• cable ties

ID Name Use

C110720 EQIK216 Installation set for RNAC

Table 5  Equipment kit EQIK216

Page 16: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 16/42

16 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e400

Confidential

RNAC cabinet

2.2 RNAC functional units and plug-in units

Figure 4 Functional units of the RNAC cabinet

Equipping rules

Capacity step RNC450/150 includes all RNAC subracks. All units except the interface

units (NIS1P, NIS1 and NIP1) are equipped in index order, starting from the lowest

index. For equipping rules of the interface units, see section NIS1P, NIS1 and NIP1

equipping rules.

1. Install all units except NIS1P, NIS1 and NIP1 0 in index order, starting from the unit

indexed as 0.

2. Install optional NIP1 0, if used.

Page 17: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 17/42

DN0639624 17

Equipment Lists for RNC450 RNAC cabinet

Id:0900d8058086e400

Confidential

3. Install 2N redundant NIS1P pairs and non-redundant NIS1 units. See the equipping

rules and restrictions in section NIS1P, NIS1 and NIP1 equipping rules.

4. Install cover plates for the slots that remain empty.

The following units are ordered separately:

• Optional second ESA24 (ESA24 1)

• Optional NIP1 0

• NIS1P/NIS1 2–3

• NIS1P 10-11

Position ID Name FU Notes

Subrack 1

F01

F02

C100580 SF10 SFU 0

F03 C105546 CDSP-C DMCU 0

F04 C105546 CDSP-C DMCU 1

F05 C100610 ESA24 ESA24 0

F06 C11054 MCP18-B OMS Mounted 4GB memory included

F07 C111034

C109093

CCP18-C

CCP18-A

RRMU 0 Mounted 2GB memory included

F08 C111034

C109093

CCP18-C

CCP18-A

RSMU 0 Mounted 2GB memory included

F09 C109700 MX622-D MXU 0

F10 C109472 PD30 – Subrack power  

F11 C109700 MX622-D MXU 1

F12 C109047 AL2S-D A2SU 0

F13 C109047 AL2S-D A2SU 1

F14

F15

C109941 HDS-B WDU 0 /

HDD 0

OMU and OMS hard disks are

located on the same adapter 

P01098 2 x WDW73 A = OMU

B = OMS (closest to front panel)

F16 C111034

C109093

CCP18-C

CCP18-A

OMU 0 Mounted 2GB memory included

F17 C111034

C109093

CCP18-C

CCP18-A

ICSU 0 Mounted 2GB memory included

F18 C111034

C109093

CCP18-C

CCP18-A

ICSU 1 Mounted 2GB memory included

F19 C08986 TSS3 TBU 0

F38 C71700 TBUF TBU 1

Subrack 2 

Table 6  Functional units, plug-in units, and memory modules of the RNAC

Page 18: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 18/42

18 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e400

Confidential

RNAC cabinet

F01

F02

C100580 SF10 SFU 1

F03 C105546 CDSP-C DMCU 2

F04 C105546 CDSP-C DMCU 3

F05 C100610 ESA24 ESA24 1 Optional

F06 C111034

C109093

CCP18-C

CCP18-A

GTPU 0 Mounted 2GB memory included

F07 C111034

C109093

CCP18-C

CCP18-A

RRMU 1 Mounted 2GB memory included

F08 C111034

C109093

CCP18-C

CCP18-A

RSMU 1 Mounted 2GB memory included

F09 C109700 MX622-D MXU 2

F10 C109472 PD30 – Subrack power  

F11 C109700 MX622-D MXU 3

F12 C109047 AL2S-D A2SU 2

F13

F14

C109941 HDS-B WDU 1 /

HDD 1

OMU and OMS hard disks are

located on the same adapter 

P01098 2 x WDW73 A = OMU

B = OMS (closest to front panel)

F15 C100880 EHAT EHU

F16 C109093 CCP18-A OMU 1 Mounted 2GB memory included

F17 C111034

C109093

CCP18-C

CCP18-A

ICSU 2 Mounted 2GB memory included

F18 C111034

C109093

CCP18-C

CCP18-A

ICSU 3 Mounted 2GB memory included

F19 C71700 TBUF TBU 0

F38 C08986 TSS3 TBU 1

Subrack 3

F01 C105546 CDSP-C DMCU 4

F02 C105546 CDSP-C DMCU 5

F03 C111034

C109093

CCP18-C

CCP18-A

ICSU 4 Mounted 2GB memory included

F04 C111034

C109093

CCP18-C

CCP18-A

ICSU 5 Mounted 2GB memory included

F05 C111034

C109093

CCP18-C

CCP18-A

ICSU 6 Mounted 2GB memory included

F06 C105546 CDSP-C DMCU 6

F07 C105546 CDSP-C DMCU 7

Position ID Name FU Notes

Table 6  Functional units, plug-in units, and memory modules of the RNAC (Cont.)

Page 19: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 19/42

DN0639624 19

Equipment Lists for RNC450 RNAC cabinet

Id:0900d8058086e400

Confidential

F08 C105546 CDSP-C DMCU 8

F09 C109700 MX622-D MXU 4

F10 C109472 PD30 – Subrack power  

F11 C109700 MX622-D MXU 5

F12 C109047 AL2S-D A2SU 3

F13 C105546 CDSP-C DMCU 9

F14 C105546 CDSP-C DMCU 10

F15 C100790 /

C100610

NI16P1A /

NI4S1-B

NIP1 0 /

NIS1P 10

Ordered separately

NIP1 0 equipping requires cabling

changes and the adding of BIE1T/C

back interface panel

NIS1P 10 can be equipped either inRNAC or RNBC.

If NIS1 3 is configured, NIS1P/NIS1

10 and NIS1P 11 in RNAC or RNBC

cannot be configured.

F16 C111034

C109093

CCP18-C

CCP18-A

GTPU 1 Mounted 2GB memory included

F17 C100610 NI4S1-B NIS1P 0 / NIS1 0 Included in capacity step

RNC450/150

F18 C100610 NI4S1-B NIS1P 2 / NIS1 2 Ordered separately

F19 C71700 TBUF TBU 0

F38 C71700 TBUF TBU 1

Subrack 4

F01 C105546 CDSP-C DMCU 11

F02 C105546 CDSP-C DMCU 12

F03 C111034

C109093

CCP18-C

CCP18-A

ICSU 7 Mounted 2GB memory included

F04 C111034

C109093

CCP18-C

CCP18-A

ICSU 8 Mounted 2GB memory included

F05 C111034

C109093

CCP18-C

CCP18-A

ICSU 9 Mounted 2GB memory included

F06 C105546 CDSP-C DMCU 13

F07 C105546 CDSP-C DMCU 14

F08 C105546 CDSP-C DMCU 15

F09 C109700 MX622-D MXU 6

F10 C109472 PD30 – Subrack power  

F11 C109700 MX622-D MXU 7

F12 C109047 AL2S-D A2SU 4

Position ID Name FU Notes

Table 6  Functional units, plug-in units, and memory modules of the RNAC (Cont.)

Page 20: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 20/42

20 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e400

Confidential

RNAC cabinet

2.3 RNAC cabinet stickers and marking strips

See Figure IPA2800 stickers in section Cabinet stickers for the locations of the marking

strips and stickers.

2.3.1 Marking strips

F13 C105546 CDSP-C DMCU 16

F14 C105546 CDSP-C DMCU 17

F15 C100610 NI4S1-B NIS1P 11 Ordered separately

NIS1P 11 can be equipped either in

RNAC or RNBC.

If NIS1 3 is configured, NIS1P/NIS1

10 and NIS1P 11 in RNAC or RNBC

cannot be configured.

F16 C111034

C109093

CCCP18-C

CCP18-A

GTPU 2 Mounted 2GB memory included

F17 C100610 NI4S1-B NIS1P 1 / NIS1 1 Included in capacity step

RNC450/150

If NIS1 1 is configured, NIS1P/NIS1 8and NIS1P 9 in RNBC cannot be con-

figured.

F18 C100610 NI4S1-B NIS1P 3 / NIS1 3 Ordered separately

If NIS1 3 is configured, NIS1P/NIS1

10 and NIS1P 11 in RNAC or RNBC

cannot be configured.

F19 C71700 TBUF TBU 0

F38 C71700 TBUF TBU 1

Position ID Name FU Notes

Table 6  Functional units, plug-in units, and memory modules of the RNAC (Cont.)

Position Name Use

F 1 RNAC F1 IPA2800 Marking Strip for subrack 1

F 2 RNAC F2 IPA2800 Marking Strip for subrack 2F 3 RNAC F3 IPA2800 Marking Strip for subrack 3

F 4 RNAC F4 IPA2800 Marking Strip for subrack 4

Table 7  Marking strips for the RNAC

Page 21: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 21/42

DN0639624 21

Equipment Lists for RNC450 RNAC cabinet

Id:0900d8058086e400

Confidential

2.3.2 Stickers

Position Code Name Use Notes

F Name sticker RNAC(window)

Network Element Sticker 

B Name sticker RNAC Network Element Sticker  

F Identifier sticker sheet Subrack position

number sticker 

F ESD sticker Each subrack 4 pcs

T Note sticker  

T UB 1 sticker Power sticker  

T UB 2 sticker Power sticker  

HDD (OMS) sticker Identification sticker for 

OMS hard disk on HDS-

B

2 pcs

WDU (OMU) sticker Identification sticker for  

OMU hard disk on HDS-

B

2 pcs

Table 8  Stickers for the RNAC

Page 22: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 22/42

22 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e401

Confidential

RNBC cabinet

3 RNBC cabinetThis section lists all the equipment mechanics for the RNBC cabinet.

3.1 RNBC cabinet mechanics

3.1.1 Subracks, fan trays, and cable supporting shelves to the front

3.1.2 Subracks for back interfaces and cable supporting shelves to the

rear 

Equipping Side Mounting

hole no.

ID Name Use

C109740 EC216 Cabinet

F C109742 DR216 Door right

F C109743 DL216 Door left

B C109742 DR216 Door right

B C109743 DL216 Door left

F C110052 CPD120-A Power distribution

and fuse unit

F C110052 CPD120-A Power distribution

and fuse unit

Table 9 RNBC cabinet mechanics

Equipping Side Mounting

hole no.

ID Name Use

F 53 C109979 SRA3 Subrack

F 49 C109730 FTRA-B Fan tray

F 37 C109979 SRA3 Subrack

F 33 C109730 FTRA-B Fan tray

F 21 C109979 SRA3 Subrack

F 17 C109730 FTRA-B Fan tray

F 5 C109979 SRA3 Subrack

F 1 C109730 FTRA-B Fan tray

Table 10  Subracks and fan trays to the front for the RNBC

Side Mounting

hole no.

ID Name Use

B 53 C110568 SRBI-C Subrack for back interfaces

B 50 C105864 CS186-B Cable supporting shelf  

Table 11 Subracks for back interfaces and cable supporting shelves for RNBC

Page 23: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 23/42

DN0639624 23

Equipment Lists for RNC450 RNBC cabinet

Id:0900d8058086e401

Confidential

3.1.3 Equipment kits

The EQIS216 equipment kit contains the following items:

• washers

• static control wrist strap

• screws

• pink minigrip bags

• locking pegs• cable ties

3.1.4 Grounding set

The grounding cables between RNAC and RNBC cabinets needs to be installed at the

site.

The grounding set contains:

• 4 pcs grounding cables

• washers

• screws

B 37 C110568 SRBI-C Subrack for back interfaces

B 35 C105864 CS186-B Cable supporting shelf  

B 21 C110568 SRBI-C Subrack for back interfaces

B 21 C105864 CS186-B Cable supporting shelf  

B 5 C110568 SRBI-C Subrack for back interfaces

B 1 C105864 CS186-B Cable supporting shelf  

Side Mounting

hole no.

ID Name Use

Table 11 Subracks for back interfaces and cable supporting shelves for RNBC (Cont.)

ID Name Use

C110721 EQIS216 Installation set for RNBC

Table 12  Equipment kit EQIS216

ID Name Use Notes

C109878 Grounding set Grounding RNAC to RNBC EC216 to EC216

Table 13 Grounding sets for RNBC

Page 24: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 24/42

24 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e401

Confidential

RNBC cabinet

Figure 5  Grounding between RNAC and RNBC

REAR SIDE OF CABINET DN0644085

EC216

EC216

Page 25: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 25/42

DN0639624 25

Equipment Lists for RNC450 RNBC cabinet

Id:0900d8058086e401

Confidential

3.2 RNBC functional units and plug-in units

Figure 6  Functional units of the RNBC cabinet

Equipping rules

Subracks 1–2 form capacity step RNC450/300, subracks 3–4 is capacity step

RNC450/450. NIS1P/NIS1 units are ordered separately as needed.

 All units except the interface units (NIS1P, NIS1) are equipped in index order, starting

from the lowest index. For equipping rules of the interface units, see section NIS1P,

NIS1 and NIP1 equipping rules.

1. Install all units except NIS1P and NIS1 in index order, starting from the lowest index.

2. Install 2N redundant NIS1P pairs and non-redundant NIS1 units. See the equipping

rules and restrictions in section NIS1P, NIS1 and NIP1 equipping rules.

RNBC

DN0624954 FRONT VIEW

     I     C      S      U 

     1     6 

     I     C      S      U 

     1     7

     I     C      S      U 

     1     8 

     D     M     C      U 

     3      1

     D     M     C      U 

     3      2

     D     M     C      U 

     3      3 

     M     X     U 

     1     2

     P     D     3      0 

     M     X     U 

     1     3 

     A     2     S      U 

     7

     D     M     C      U 

     3      4

       T       B       U 

       1

       T       B       U 

       0 

     D     M     C      U 

     3      0 

       - D     M     C      U 

     3      6 

     D     M     C      U 

     3      5 

     N     I     S      1     P

     /       N

     I     S      1     8 

     N     I     S      1     P     / 

      N     I     S      1     1     0 

     G      T     P     U 

     6 

     I     C      S      U 

     1     3 

     I     C      S      U 

     1     4

     I     C      S      U 

     1     5 

       - D     M     C      U      2     6 

     D     M     C      U      2     7

     M     X     U 

     1     0 

     P     D     3      0 

     M     X     U 

     1     1

     A     2     S      U 

     6 

     D     M     C      U      2     8 

       T       B       U 

       1

       T       B       U 

       0 

     D     M     C      U      2

     5 

       - G      T     P     U      4

     D     M     C      U      2     9 

     N     I     S      1     P     5 

     N     I     S      1     P     7

     G      T     P     U      5 

     I     C      S      U 

     1     0 

     I     C      S      U 

     1     1

     I     C      S      U 

     1     2

     D     M     C      U 

     1     9 

     D     M     C      U 

     2     0 

     D     M     C      U 

     2     1

     M     X     U 

     8 

     P     D     3      0 

     M     X     U 

     9 

     A     2     S      U 

     5 

     D     M     C      U 

     2     2

       T       B       U 

       1

       T       B       U        0 

     D     M     C      U 

     1     8 

       - D     M     C      U 

     2     4

     D     M     C      U 

     2     3 

     N     I     S      1     P     / 

      N     I     S      1     4

     N     I     S      1     P     / 

      N     I     S      1     6 

     G      T     P     U 

     3 

     I     C      S      U 

     1     9 

     I     C      S      U 

     2     0 

     I     C      S      U 

     2     1

     D     M     C      U 

     3      8 

     D     M     C      U 

     3      9 

     D     M     C      U 

     4     0 

     M     X     U 

     1     4

     P     D     3      0 

     M     X     U 

     1     5 

     A     2     S      U 

     8 

     D     M     C      U 

     4     1

       T       B       U 

       1

       T       B       U 

       0 

     D     M     C      U 

     3      7

       - D     M     C      U 

     4     3 

     D     M     C      U 

     4     2

     N     I     S      1     P     9 

     N     I     S      1     P     1     1

     G      T     P     U 

     7

Page 26: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 26/42

26 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e401

Confidential

RNBC cabinet

3. Install cover plates for the slots that remain empty.

Position ID Name FU Notes

Subrack 1

F01 — — —

F02 C105546 CDSP-C DMCU 18

F03 C111034

C109093

CCP18-C

CCP18-A

ICSU 10 Mounted 2GB memory included

F04 C111034

C109093

CCP18-C

CCP18-A

ICSU 11 Mounted 2GB memory included

F05 C111034

C109093

CCP18-C

CCP18-A

ICSU 12 Mounted 2GB memory included

F06 C105546 CDSP-C DMCU 19

F07 C105546 CDSP-C DMCU 20

F08 C105546 CDSP-C DMCU 21

F09 C109700 MX622-D MXU 8

F10 C109472 PD30 – Subrack power  

F11 C109700 MX622-D MXU 9

F12 C109047 AL2S-D A2SU 5

F13 C105546 CDSP-C DMCU 22

F14 C105546 CDSP-C DMCU 23

F15 C105546 CDSP-C DMCU 24

F16 C111034

C109093

CCP18-C

CCP18-A

GTPU 3 Mounted 2GB memory included

F17 C100610 NI4S1-B NIS1P 4 / NIS1 4 Ordered separately

F18 C100610 NI4S1-B NIS1P 6 / NIS1 6 Ordered separately

F19 C71700 TBUF TBU 0

F38 C71700 TBUF TBU 1

Subrack 2 

F01 — — —

F02 C105546 CDSP-C DMCU 25

F03 C111034

C109093

CCP18-C

CCP18-A

ICSU 13 Mounted 2GB memory included

F04 C111034

C109093

CCP18-C

CCP18-A

ICSU 14 Mounted 2GB memory included

F05 C111034

C109093

CCP18-C

CCP18-A

ICSU 15 Mounted 2GB memory included

F06 — — —

Table 14 Functional units and plug-in units of the RNBC

Page 27: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 27/42

DN0639624 27

Equipment Lists for RNC450 RNBC cabinet

Id:0900d8058086e401

Confidential

F07 C105546 CDSP-C DMCU 26

F08 C105546 CDSP-C DMCU 27

F09 C109700 MX622-D MXU 10

F10 C109472 PD30 – Subrack power  

F11 C109700 MX622-D MXU 11

F12 C109047 AL2S-D A2SU 6

F13 C105546 CDSP-C DMCU 28

F14 C105546 CDSP-C DMCU 29

F15 C111034

C109093

CCP18-C

CCP18-A

GTPU 4 Mounted 2GB memory included

F16 C111034

C109093

CCP18-C

CCP18-A

GTPU 5 Mounted 2GB memory included

F17 C100610 NI4S1-B NIS1P 5 Ordered separately

F18 C100610 NI4S1-B NIS1P 7 Ordered separately

F19 C71700 TBUF TBU 0

F38 C71700 TBUF TBU 1

Subrack 3

F01 — — —

F02 C105546 CDSP-C DMCU 30

F03 C111034C109093

CCP18-CCCP18-A

ICSU 16 Mounted 2GB memory included

F04 C111034

C109093

CCP18-C

CCP18-A

ICSU 17 Mounted 2GB memory included

F05 C111034

C109093

CCP18-C

CCP18-A

ICSU 18 Mounted 2GB memory included

F06 C105546 CDSP-C DMCU 31

F07 C105546 CDSP-C DMCU 32

F08 C105546 CDSP-C DMCU 33

F09 C109700 MX622-D MXU 12

F10 C109472 PD30 – Subrack power  

F11 C109700 MX622-D MXU 13

F12 C109047 AL2S-D A2SU 7

F13 C105546 CDSP-C DMCU 34

F14 C105546 CDSP-C DMCU 35

F15 C105546 CDSP-C DMCU 36

F16 C111034

C109093

CCP18-C

CCP18-A

GTPU 6 Mounted 2GB memory included

Position ID Name FU Notes

Table 14 Functional units and plug-in units of the RNBC (Cont.)

Page 28: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 28/42

28 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e401

Confidential

RNBC cabinet

F17 C100610 NI4S1-B NIS1P 8 / NIS1 8 Ordered separately

When NIS1 1 is configured, the

NIS1P/NIS1 8 and NIS1P 9 inRNBC cannot be configured.

F18 C100610 NI4S1-B NIS1P 10 /

NIS1 10

Ordered separately

NIS1P 10 and NIS1P 11 can be

equipped either in RNAC or 

RNBC. If they are configured in

RNAC, cabling changes are

needed.

When NIS1 3 is configured, the

NIS1P/NIS1 10 and NIS1P 11 in

RNAC or RNBC cannot be con-

figured.

F19 C71700 TBUF TBU 0

F38 C71700 TBUF TBU 1

Subrack 4

F01 — — —

F02 C105546 CDSP-C DMCU 37

F03 C111034

C109093

CCP18-C

CCP18-A

ICSU 19 Mounted 2GB memory included

F04 C111034

C109093

CCP18-C

CCP18-A

ICSU 20 Mounted 2GB memory included

F05 C111034

C109093

CCP18-C

CCP18-A

ICSU 21 Mounted 2GB memory included

F06 C105546 CDSP-C DMCU 38

F07 C105546 CDSP-C DMCU 39

F08 C105546 CDSP-C DMCU 40

F09 C109700 MX622-D MXU 14

F10 C109472 PD30 – Subrack power  

F11 C109700 MX622-D MXU 15

F12 C109047 AL2S-D A2SU 8

F13 C105546 CDSP-C DMCU 41

F14 C105546 CDSP-C DMCU 42

F15 C105546 CDSP-C DMCU 43

F16 C111034

C109093

CCP18-C

CCP18-A

GTPU 7 Mounted 2GB memory included

F17 C100610 NI4S1-B NIS1P 9 Ordered separately

When NIS1 1 is configured, the

NIS1P/NIS1 8 and NIS1P 9 in

RNBC cannot be configured.

Position ID Name FU Notes

Table 14 Functional units and plug-in units of the RNBC (Cont.)

Page 29: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 29/42

DN0639624 29

Equipment Lists for RNC450 RNBC cabinet

Id:0900d8058086e401

Confidential

3.3 RNBC cabinet stickers and marking strips

See Figure IPA2800 stickers in Section Cabinet stickers for the locations of the marking

strips and stickers.

3.3.1 Marking strips

3.3.2 Stickers

F18 C100610 NI4S1-B NIS1P 11 Ordered separately

NIS1P 10 and NIS1P 11 can be

equipped either in RNAC or RNBC. If they are configured in

RNAC, cabling changes are

needed.

When NIS1 3 is configured, the

NIS1P/NIS1 10 and NIS1P 11 in

RNAC or RNBC cannot be con-

figured.

F19 C71700 TBUF TBU 0

F38 C71700 TBUF TBU 1

Position ID Name FU Notes

Table 14 Functional units and plug-in units of the RNBC (Cont.)

Position Name Use

F 1 RNBC F1 IPA2800 Marking Strip for subrack 1

F 2 RNBC F2 IPA2800 Marking Strip for subrack 2

F 3 RNBC F3 IPA2800 Marking Strip for subrack 3

F 4 RNBC F4 IPA2800 Marking Strip for subrack 4

Table 15  Marking strips for the RNBC

Position Name Use Notes

F Name sticker RNBC

(window)

Network Element Sticker 

B Name sticker RNBC Network Element Sticker  

F Identifier sticker  

sheet

Subrack position number sticker 

F ESD sticker Each subrack 4 pcs

T Note sticker  

T UB 1 sticker Power sticker  

T UB 2 sticker Power sticker  

Table 16  Stickers for the RNBC

Page 30: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 30/42

30 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e416

Confidential

NIS1P, NIS1 and NIP1 equipping rules

4 NIS1P, NIS1 and NIP1 equipping rulesThis section describes the equipping rules for interface units NIS1P, NIS1 and NIP1 in

RNC450.

4.1 NIP1 equipping rules

RNC450 features one optional NIP1 0 unit. It can be equipped as an alternative to

NIS1P 10 in RNAC subrack 3 slot 15.

When NIP1 0 is equipped, cabling changes are needed and the BIE1T/BIE1C back

interface needs to equipped at the rear of the subrack. For the RNAC LVDS cabling

changes, see Cable Lists for RNC450 and chapter 6 Adding optional NIP1 unit to

RNC450.

4.2 NIS1P and NIS1 equipping rulesThe Network Interface Unit STM-1 (NI4S1-B) provides the RNC high bandwidth STM-

1/OC-3 ATM interfaces. The unit might be configured either with 2N equipment protec-

tion or without 2N equipment protection. When configured with 2N equipment protection

the functional unit name is NIS1P. When configured without 2N equipment protection

the functional unit name is NIS1.

Non-redundant NIS1 and 2N redundant NIS1P units can be mixed in the same network

element. The number of units in mixed configuration is limited by the number of SFU

ports available for the STM-1 interface units.

Number and type of STM-1/OC-3 interfaces and units in RNC450

Table 11 STM-1/OC-3 ATM interfaces in RNC450 displays the type, and the number of 

interfaces supported by various RNC450 configurations.

Configuration Max number of  

unprotected units

Max number of 2N

protected units

Number of unpro-

tected interfaces

(NIS1)

Number of pro-

tected interfaces

(NIS1P)

RNC450 step 1 4 4 or 61 (2 or 3 pairs) 16 8+8 or 12+12 1

RNC450 step 2 6 6 (3 pairs) 24 16+16 or 20+202

RNC450 step 3 12 12 (6 pairs) 24 24+24

1 6 units and 12+12 interfaces applies only if NIP1 is not used.

2 10 units and 20+20 interfaces applies only if NIP1 is not used.

Table 17  STM-1/OC-3 ATM interfaces in RNC450

Page 31: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 31/42

DN0639624 31

Equipment Lists for RNC450 NIS1P, NIS1 and NIP1 equipping rules

Id:0900d8058086e416

Confidential

4.2.1 Equipping NIS1P and NIS1 units to RNC450 step 1

Figure 2 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 1 shows the correct

locations for NIx1x units.

Figure 7  NIS1P, NIS1 and NIP1 equipping positions inRNC450 step 1

Table 12 Number of units in mixed configurations of 2N redundant and non-redundant 

units in RNC450 step 1 describes how many units can be configured as 2N redundant

when also non-redundant units are used, and vice versa.

DN70392866

RNAC

      N      I      S       1      P

      0 

      /        N

      I      S       1

      0 

      N      I      S       1      P

      2

      /        N

      I      S       1

      2

      N      I      S       1      P

      1

      /        N

      I      S       1

      1

      N      I      S       1      P

      3 

      /        N

      I      S       1

      3 

      N      I      S       1      P

      1      0 

      /        N

      I      P      1

      0 

      N      I      S       1      P

      1      1

Optionalequippingpositions for NIS1P 10-11in RNAC,if NIP1 0 is notequipped

Equippingposition for optionalNIP1 0

Page 32: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 32/42

32 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e416

Confidential

NIS1P, NIS1 and NIP1 equipping rules

The number of units in mixed configuration is limited by the number of SFU ports avail-

able for the STM-1 interface units. The equipping restrictions in RNC450 step 1 are:

• When NIS1 3 is configured, the NIS1P 10 and NIS1P 11 cannot be configured. See,

figure 6 NIS1 3 equipping restriction.

• NIS1P 10 and NIS1P 11 can be equipped either in RNAC (optional) or RNBC

(default). If they are equipped in RNAC, cabling changes are needed. For the RNAC

LVDS cabling changes, see Cable Lists for RNC450 and chapter 5 Adding NIS1P

and NIS1 units to RNC450

Non-redundant NIS1 units

No. of 

units

0 1 2 3 4 5 6

No. of 

inter-

faces

0 4 8 12 16 20 24

2N redundant

NIS1P units

0 pair 0+0 x x x x x - -

1 pair 4+4 x x x x - - -

2 pair 8+8 x x x - - - -

3 pair 12+12 x - - - - - -

Table 18  Number of units in mixed configurations of 2N redundant and non-redun-

dant units in RNC450 step 1

Page 33: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 33/42

DN0639624 33

Equipment Lists for RNC450 NIS1P, NIS1 and NIP1 equipping rules

Id:0900d8058086e416

Confidential

4.2.2 Equipping NIS1P and NIS1 units to RNC450 step 2

Figure 3 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 2 shows the correct

locations for NIx1x units.

Figure 8  NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 2

Table 13 Number of units in mixed configurations of 2N redundant and non-redundant 

units in RNC450 step 2 describes how many units can be configured as 2N redundant

when also non-redundant units are used, and vice versa.

DN70392893

RNAC RNBC

      N      I      S       1      P

      0 

      /        N

      I      S       1

      0 

      N      I      S       1      P

      2

      /        N

      I      S       1

      2

      N      I      S       1      P

      1

      /        N

      I      S       1

      1

      N      I      S       1      P

      3 

      /        N

      I      S       1

      3 

      N      I      S       1      P

      4

      /        N

      I      S       1

      4

      N      I      S       1      P

      6 

      /        N

      I      S       1

      6 

      N      I      S       1      P

      5 

      N      I      S       1      P

      7

      N      I      S       1      P

      1      0 

      /        N

      I      P      1

      0 

      N      I      S       1      P

      1      1

Optionalequippingpositions for NIS1P 10-11in RNAC,if NIP1 0 is notequipped

NIS1P 5 and 7units are equippedonly when the unitsare configuredwith 2n redundancy

Equippingposition for optionalNIP1 0

Page 34: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 34/42

34 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e416

Confidential

NIS1P, NIS1 and NIP1 equipping rules

The number of units in mixed configuration is limited by the number of SFU ports avail-

able for the STM-1 interface units. The equipping restrictions in RNC450 step 2 are:

• When NIS1 3 is configured, the NIS1P 10 and NIS1P 11 cannot be configured. See

figure 6 NIS1 3 equipping restriction.

• NIS1P 10 and NIS1P 11 can be equipped either in RNAC (optional) or RNBC

(default). If they are configured in RNAC, cabling changes are needed. For the

RNAC LVDS cabling changes, see Cable Lists for RNC450 and chapter 5 Adding

NIS1P and NIS1 units to RNC450.

Non-redundant NIS1 units

No. of 

units

0 1 2 3 4 5 6

No. of 

interfaces

0 4 8 12 16 20 24

2N redundant

NIS1P units

0 pair 0+0 x x x x x x x

1 pair 4+4 x x x x x x -

2 pair 8+8 x x x x x - -

3 pair 12+12 x x x - - - -

4 pair 16+16 x - - - - - -

5 pair 20+20 x - - - - - -

Table 19 Number of units in mixed configurations of 2N redundant and non-redun-

dant units in RNC450 step 2

Page 35: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 35/42

DN0639624 35

Equipment Lists for RNC450 NIS1P, NIS1 and NIP1 equipping rules

Id:0900d8058086e416

Confidential

4.2.3 Equipping NIS1P and NIS1 units to RNC450 step 3

Figure 4 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 3 shows the correct

locations for NIx1x units.

Figure 9 NIS1P, NIS1 and NIP1 equipping positions in RNC450 step 3

Table 14 Number of units in mixed configurations of 2N redundant and non-redundant 

units in RNC450 step 3 describes, how many units can be configured as 2N redundant

when also non-redundant units are used, and vice versa.

DN70347799

RNAC RNBC

      N      I      S       1      P

      0 

      /        N

      I      S       1

      0 

      N      I      S       1      P

      2

      /        N

      I      S       1

      2

      N      I      S       1      P

      1

      /        N

      I      S       1

      1

      N      I      S       1      P

      3 

      /        N

      I      S       1

      3 

      N      I      S       1      P

      4

      /        N

      I      S       1

      4

      N      I      S       1      P

      6 

      /        N

      I      S       1

      6 

      N      I      S       1      P

      5 

      N      I      S       1      P

      7

      N      I      S       1      P

      8 

      /        N

      I      S       1

      8 

      N      I      S       1      P

      1      0 

      /        N

      I      S       1

      1      0 

      N      I      S       1      P

      9 

      N      I      S       1      P

      1      1

      N      I      S       1      P

      1      0 

      /        N

      I      P      1

      0 

      N      I      S       1      P

      1      1

 Alternativeequippingpositions for NIS1P 10-11

NIS1P 5, 7, 9 and 11units are equippedonly when the unitsare configuredwith 2n redundancy

Equippingposition for optionalNIP1 0

Page 36: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 36/42

36 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e416

Confidential

NIS1P, NIS1 and NIP1 equipping rules

The number of units in mixed configuration is limited by the number of SFU ports avail-

able for the STM-1 interface units. The equipping restrictions in RNC450 step 3 are:

• When NIS1 1 is configured, the NIS1P 8 and NIS1P 9 in RNBC cannot be config-

ured. See figure 5 NIS1 1 equipping restriction.

• When NIS1 3 is configured, the NIS1P/NIS1 10 and NIS1P 11 in RNAC or RNBC

cannot be configured. See, figure 6 NIS1 3 equipping restriction.

• NIS1P 10 and NIS1P 11 can be equipped either in RNAC or RNBC. If they are con-

figured in RNAC, cabling changes are needed. For the RNAC LVDS cabling

changes, see Cable Lists for RNC450 and chapter 5 Adding NIS1P and NIS1 units

to RNC450.

Non-redundant NIS1 units

No. of 

units

0 1 2 3 4 5 6

No. of 

inter-

faces

0 4 8 12 16 20 24

2N redundant

NIS1P units

0 pair 0+0 x x x x x x x

1 pair 4+4 x x x x x x -

2 pair 8+8 x x x x x - -

3 pair 12+12 x x x x - - -

4 pair 16+16 x x x - - - -

5 pair 20+20 x x - - - - -

6 pair 24+24 x - - - - - -

Table 20  Number of units in mixed configurations of 2N redundant and non-redun-

dant units in RNC450 step 3

Page 37: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 37/42

DN0639624 37

Equipment Lists for RNC450 NIS1P, NIS1 and NIP1 equipping rules

Id:0900d8058086e416

Confidential

Figure 10  NIS1 1 equipping restriction

DN70347378

RNAC RNBC

      N      I      S       1      P

      0 

      /        N

      I      S       1

      0 

      N      I      S       1      P

      2

      /        N

      I      S       1

      2

      N      I      S       1

      1

      N      I      S       1      P

      3 

      /        N

      I      S       1      3 

      N      I      S       1      P

      4

      /        N

      I      S       1

      4

      N      I      S       1      P

      6 

      /        N

      I      S       1

      6 

      N

      I      S       1      P

      5 

      N

      I      S       1      P

      7

      N      I      S       1      P

      8 

      /        N

      I      S       1

      8 

      N      I      S       1      P

      1      0 

      /        N

      I      S       1

      1      0 

      N      I      S       1      P

      9 

      N      I      S       1      P

      1      1

      N      I      S       1      P

      1      0 

      N      I      S       1      P

      1      1

If NIS1 1 is

equipped,NIS1P 8-9cannot beequipped inRNBC

Page 38: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 38/42

38 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e416

Confidential

NIS1P, NIS1 and NIP1 equipping rules

Figure 11 NIS1 3 equipping restriction

DN70399108

RNAC RNBC

      N      I      S       1      P

      0 

      /        N

      I      S       1

      0 

      N      I      S       1      P

      2

      /        N

      I      S       1

      2

      N      I      S       1      P

      1

      /        N

      I      S       1      1

      N      I      S       1

      3 

      N      I      S       1      P

      4

      /        N

      I      S       1

      4

      N      I      S       1      P

      6 

      /        N

      I      S       1

      6 

      N

      I      S       1      P

      5 

      N

      I      S       1      P

      7

      N      I      S       1      P

      8 

      /        N

      I      S       1

      8 

      N      I      S       1      P

      1      0 

      /        N

      I      S       1

      1      0 

      N      I      S       1      P

      9 

      N      I      S       1      P

      1      1

      N      I      S       1      P

      1      0 

      N      I      S       1      P

      1      1

If NIS1 3 isequipped,NIS1P 10-11cannot beequipped inRNAC or RNBC.

Page 39: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 39/42

DN0639624 39

Equipment Lists for RNC450 Cabinet stickers

Id:0900d8058086e417

Confidential

5 Cabinet stickers

Figure 12  IPA2800 cabinet; note that front and back sides are identical

Radio Network Controller 

RNAC

IPA2800

DN01173112

Page 40: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 40/42

40 DN0639624

Equipment Lists for RNC450

Id:0900d8058086e417

Confidential

Cabinet stickers

Figure 13 IPA2800 cabinet stickers; the stickers in the figure are attached to all

cabinets except Network Element Name stickers and Marking strips

 ATTENTION!Observeprecautionsfor handlingelectrostaticsensitivedevices UL

THE EDGES OF

THE CABINET

MAY BE SHARP

WARNING

UL

(2 PCS)

CAMA

FOR DC SUPPLYFUSE VALUESREFER TOUSER MANUAL

NOTE

DN01173093

3:MARKING STRIP SR4

3:MARKING STRIP SR3

3:MARKING STRIP SR2

3:MARKING STRIP SR1

6:ESD STICKER(4 PCS)

SRA1 IDENTIFIER STICKER

2:NAME STICKER RNAC (2pcs)

1:NAME STICKER CAMA (2pcs)

5:NOTE STICKER

8:DELIVERY STICKER

(2 PCS)

4: 4

4: 3

4: 2

4: 1

7:UB STICKER

UB2UB1

CAMA

RNAC

Radio Network Controller 

Multimedia Gateway

Page 41: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 41/42

DN0639624 41

Equipment Lists for RNC450 Cabinet stickers

Id:0900d8058086e417

Confidential

Figure 14 Stickers already attached on delivery

Guidelines for product collection and safe disposal of the equipment are indicated with

a sticker placed on the equipment, shown in the figure below.

 ATTENTION!Observeprecautionsfor handlingelectrostaticsensitivedevices UL

THE EDGES OF

THE CABINET

MAY BE SHARP

WARNING

UL

38

EARTHBONDING

POINT

DN03462321

EQUIPPINGSETSUSED IN

THISCABINET

B Cabinet type A

B Upgrade set A

B Upgrade set A

B Upgrade set A

B Upgrade set A

B Location set A

B Alternative set A

B Alternative set A

B Upgrade set A

B Alternative set A

LOT ID LABEL

(2PCS)(2PCS)

(2PCS)

Page 42: equipmentlist RNC450

7/27/2019 equipmentlist RNC450

http://slidepdf.com/reader/full/equipmentlist-rnc450 42/42

Equipment Lists for RNC450Cabinet stickers

Figure 15  Product collection and disposal within the European Union

g Stickers attached on delivery include: ESD caution sticker, LOT ID label, Warning

sticker about sharp edges, Earth Bonding Point sticker, WEEE sticker, and Equipping

sticker (the latter is located at the top of the cabinet).

Product collection and disposal within the European Union

Do not dispose of the

product as unsortedmunicipal waste. Thecrossed-out wheeledbin means that at theend of the product'slife it must be takento separate collection.

Note: this is applicable onlywithin the European Union(see WEEE Directive 2002/96/EC)

DN0577953