ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy...

25
ENERGY PERFORMANCE CERTIFICATE PACKAGE Unit 13, James Morrison Street, Glasgow June 2009

Transcript of ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy...

Page 1: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

ENERGY PERFORMANCE CERTIFICATE PACKAGE Unit 13, James Morrison Street, Glasgow June 2009

Page 2: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

CONTENTS

1.0 COVERING LETTER 2.0 ENERGY PERFORMANCE CERTIFICATE 3.0 ZONING DRAWINGS 4.0 LETTING PARTICULARS 5.0 PHOTOGRAPHS 6.0 RECOMMENDATIONS REPORT

Page 3: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

Covering Letter

Page 4: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

DMW/TS/B48930 Scott MacKinnon City Link Developments 119 Whitefield Road GLASGOW G52 2SD 10 June 2009 Dear Scott ENERGY PERFORMANCE CERTIFICATE UNIT 13, JAMES MORRISON STREET, GLASGOW Please find enclosed two copies of the EPC package for your use and consideration. Within this package, I enclose a set of floor plans which have been drawn and used to assist in the input of data into the Lifespan SBEM software, ensuring the accuracy of the EPC. For your information, there are numerous recommendations, some of which you may wish to consider in order to reduce the in use energy costs. Certainly this information will be useful to any future occupier. I trust this exercise has provided the information that you require and would welcome any further instructions in the future. Many thanks for your enquiry. Yours sincerely

Murray Watson Associate Director – Chartered Building Surveyor Direct Dial: 0141 300 8023 Mobile: 07799 891 810 E-mail: [email protected]

Enc

Page 5: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

Energy Performance Certificate

Page 6: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.
Page 7: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

Zoning Drawings

Page 8: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

Circulation Area (corridors & stairways)

Open Plan Offices

Plant

Storage Area

Tea Making

Toilet

3 m²Toilet

00/0316 m²

Open Plan Offices

00/06

1 m²Storage Area

00/02

1 m²Plant

00/04

1 m²Tea Making

00/05

7 m²

Circulation Area(corridors & stairways)

00/01

2980

2785 5705

1355

900

2100

1210

715

1895 790

1250

1430

1210 685 790

H:3320mmW:1195mm

H:3320mmW:1155mm

H:3320mmW:1175mm

H:2200mmW:1175mm

17 m²Open Plan Offices

00/07

2730

5755

Ground floor level

First floor level

2590

2195

0.000

2.590

4.785 First floor ceiling level

Job Title

Drawing title

Drawing Number

226 West George Street, Glasgow, G2 2LNtel: 0141 300 8000fax: 0141 300 8001

e: [email protected]

www.jamesbarr.co.uk

Scale: Date: Drawn:

Job number

Sheet size:A3

Revision

Unit 13,James Morrison Street,Glasgow G1 5PE

As indicated

City Link Developments

Ground floor plan as existingshowing EPC zones

B48930

29.05.09 GB

B48930

(EX) 01

Note

This drawing is for SBEM calculation and EPC productionpurposes only

All dimensions refer to centrelines of internal walls andinternal faces of external walls unless stated otherwise

Zoning area boundaries refer to centrelines of internal wallsand internal faces of external walls

1 : 50

Ground floor plan as existing

00 - Ground Floor Zone ScheduleZone

number Occupancy Area

00/01 Circulation Area (corridors & stairways) 7 m²00/02 Storage Area 1 m²00/03 Toilet 3 m²00/04 Plant 1 m²00/05 Tea Making 1 m²00/06 Open Plan Offices 16 m²00/07 Open Plan Offices 17 m²00 - Ground floor level: 7 46 m²

Section - zone heights

Page 9: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

20 m²Open Plan Offices

01/01

Circulation Area (corridors & stairways)

Open Plan Offices

Plant

Storage Area

Tea Making

Toilet

Void above

2730

5705

790

1705

620

536

405

3150

2205

2210

3345

2737

Ground floor level

First floor level

2590

2195

0.000

2.590

4.785 First floor ceiling level

Job Title

Drawing title

Drawing Number

226 West George Street, Glasgow, G2 2LNtel: 0141 300 8000fax: 0141 300 8001

e: [email protected]

www.jamesbarr.co.uk

Scale: Date: Drawn:

Job number

Sheet size:A3

Revision

Unit 13,James Morrison Street,Glasgow G1 5PE

As indicated

City Link Developments

First floor as existing showingEPC zones

B48930

03/13/09 GB

B48930

(EX) 02

Note

This drawing is for SBEM calculation and EPC productionpurposes only

All dimensions refer to centrelines of internal walls andinternal faces of external walls unless stated otherwise

Zoning area boundaries refer to centrelines of internal wallsand internal faces of external walls

1 : 50

First floor plan as existing

01 - First Floor Zone ScheduleZone

number Occupancy Area

01/01 Open Plan Offices 20 m²01 - First floor level: 1 20 m²

Section - zone heights

Page 10: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

Letting Particulars

Page 11: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.
Page 12: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

Photographs

Page 13: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

1

2

Page 14: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

3

4

Page 15: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

5 6

Page 16: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

7 8

Page 17: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

9 10

Page 18: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.

Recommendations Report

Page 19: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.
Page 20: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.
Page 21: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.
Page 22: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.
Page 23: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.
Page 24: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.
Page 25: ENERGY PERFORMANCE CERTIFICATE PACKAGEbulkloader.prd.pl.artirix.com.s3.amazonaws.com/... · energy performance certificate package unit 13, james morrison street, glasgow june 2009.