33LElectronic pressure switches
Vacuum and relative pressure -1 to 600 bar
Technical dataMedium:Gaseous, liquid, aggressive and neutral, non-combustibleElectrical connection:M 12 x 1Mounting:OptionalFluid temperature:-25C to + 80CAmbient temperature:-20C to + 80CConsult our Technical Service for use below +2C.
Pressure range:-1 to 1 / 16 / 40 / 100 / 160 / 250 / 400 / 600 barTemperature sensitivity (zero point):0,4% of final value/10 KTemperature sensitivity (range):0,4% of final value/10 KSwitching point:Adjustable between 0 to 100% of FSReset point:Adjustable between 0 to 100% of FSAccuracy: 1,5% FS(Linearity, hysteresis, repeatability)Degree of protection to DIN 40 050:IP65 (10bar), with plug mountedShock protection:30g, xyz, DIN EN 60068-2-27Vibration protection:10g, 5 to 500 Hz, xyz, DIN EN 60068-2-6Weight:0,06 kg
MaterialsHousing: aluminium, stainless steel, polyesterWetted parts:-1 to 16 bar: aluminium, ceramics, FKM (viton)40 to 600 bar: atainless steel, ceramics, FKM (viton)All parts free of laquer impairing substances
Diagnostic function acc. to DESINA
Display of system pressure
Easy programming of switchpoints
Economic solution for industrial applications
Switching status indicated by 3-colour LED display
Free of laquer impairing substances
Ordering informationSee page 2
Electrical informationSee page 2
-
4/04N/UK 5.11.371.02
33L
Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
Ordering informationElectronic pressure switch, pressure range 0 to 16 bar, fluid connection G 1/4 femalequote: 00886600113300
08601
Fluid connection SubstituteG1/4 0Flange 6
Pressure ranges (bar) Substitute-1 ... 1 10 ... 10 20 ... 16 30 ... 40 40 ... 100 50 ... 160 60 ... 250 70 ... 400 80 ... 600 9
Electrical connection: M12 x 1Power supply: UB =18 to 32 V d.c., polarity safePermissible residual ripple: 10% (within UB)Current consumption: < 100 mA (plus load current)Switching mode: PNP, Potential-bound open collector switching to UBOutput signal: Out 1: switching: UB minus 1.5V / Imax. 250 mA
Out 2: diagnostic/switching UB minus 1,5V/250 mASurge and short-circuit protection (Out1/Out2)
Switching logic Out 1 & 2: NO/NC programmableResponse time: < 10 msService life: min. 50 million switching cyclesElectromagnetic compatibility: Interference emission acc. to EN 61326
Interference immunity acc. to EN 61326 Part 1
NORGREN None Bar** NO 50% 48% DESINA (NC) 2% Yellow 50%
Setting
* OUT 2 function is programmable: diagnostic acc. to DESINA /switching** p.s.i. on request
Code Pressure unit OUT 1Switching logic(NO/NC)
Switch point (% of range)
Reset point (% of range)
Switch point (% of range)
Reset point (% of range)
OUT 2*Switching logic(NO/NC)
Displayzero point suppression(% of range)
Colour Brightness
Factory setting
Electrical information
-1 ... 1 bar 6 G1/4 2 x PNP 0,01 0860110-1 ... 1 bar 6 Flange 2 x PNP 0,01 08601160 ... 10 bar 25 G1/4 2 x PNP 0,05 08601200 ... 10 bar 25 Flange 2 x PNP 0,05 08601260 ... 16 bar 40 G1/4 2 x PNP 0,1 08601300 ... 16 bar 40 Flange 2 x PNP 0,1 08601360 ... 40 bar 100 G1/4 2 x PNP 0,2 08601400 ... 40 bar 100 Flange 2 x PNP 0,2 08601460 ... 100 bar 175 G1/4 2 x PNP 0,2 08601500 ... 100 bar 175 Flange 2 x PNP 0,2 08601560 ... 160 bar 280 G1/4 2 x PNP 1,0 08601600 ... 160 bar 280 Flange 2 x PNP 1,0 08601660 ... 250 bar 400 G1/4 2 x PNP 1,0 08601700 ... 250 bar 400 Flange 2 x PNP 1,0 08601760 ... 400 bar 700 Flange 2 x PNP 2,0 08601860 ... 600 bar 1000 G1/4 2 x PNP 3,0 08601900 ... 600 bar 1000 Flange 2 x PNP 3,0 0860196
Pressure range (bar)# Max. value (bar)## Fluid connection* Output signal** Display step size (bar) Model
* Versions with fluid connection 1/4 NPTF on request, versions with bleeder screw on request** Mode of OUT2 is programmable: Diagnostic acc. to DESINA / switching, switching logic of OUT1 and /OUT2 is programmable (NO/NC)# Versions with pressure unit psi on request## Max. value = over pressure. Short-term pressure peaks are not allowed to exceed this limit value during operation.Operative utilization of the overload range is not permitted.
Options selector
-
4/04N/UK 5.11.371.03
33L
Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.
M12x1 25
19,5
70
82,8
20
5,5
7,5
1
3
2
30
30
3 2
54 1
M12x1 25
19,5
70
82,8
20
5,5
7,5
30
30
3 2
54 1
1,2
8
3
2
3
2
1 G1/4, 12 deep or 1/4 NPT, 10 deep
LED Out 2 (on/off)
Bleeder screw on request
5
14
23
1 +U Brown2 Out 2 (diagnostic /switch, PNP) White Red blinking / LED3 0 V Blue4 Out 1 (switch, PNP) Black Yellow / green 5 NC
Warning
These products are intended for use in industrial compressed airsystems only. Do not use these products where pressures andtemperatures can exceed those listed under Technical Data.
Before using these products with fluids other than those specified, fornon-industrial applications, life-support systems, or other applicationsnot within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid powersystems can fail in various modes.
The system designer is warned to consider the failure modes of allcomponent parts used in fluid power systems and to provide adequatesafeguards to prevent personal injury or damage to equipment in theevent of such failure.
System designers must provide a warning to end users in thesystem instructional manual if protection against a failure modecannot be adequately provided.
System designers and end users are cautioned to review specificwarnings found in instruction sheets packed and shipped with theseproducts.
Accessories
0574767 0574773 0799845 (2 m cable length) 0523058 (2 m cable length) 0523056 (without cable) 0523057 (2 m cable length) 0523055 (without cable)0250081 (5 m cable length) 0523053 (5 m cable length) 0523052 (5 m cable length)
Pressure portreducing nipple
Snubber Connector M 12x1905 pins (on PE-requirement)
Connector M 12x1904 pins
Connector M 12x1Straight4 pins
Electrical connection M 12 x 1
Electrical connection M12 x 1Pin no. Signal Cable
Display
Accessories
Pressure portreducing nippleMaterial: brassModel: 0574767Material: stainless steel(1.4301)Model: 0550083
G 1/4 A
G 1/2 A
3143
22
SnubberMaterial: brassModel: 0574773Material: stainless steel(1.4301)Model: 0553258
G 1/4 A
3446
G 1/421,5
22