en_5.11.37105 602 PS10Switch (Ex-proof)

3
4/04 N/UK 5.11.371.01 Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. 33L Electronic pressure switches Vacuum and relative pressure -1 to 600 bar Technical data Medium: Gaseous, liquid, aggressive and neutral, non-combustible Electrical connection: M 12 x 1 Mounting: Optional Fluid temperature: -25°C to + 80°C Ambient temperature: -20°C to + 80°C Consult our Technical Service for use below +2°C. Pressure range: -1 to 1 / 16 / 40 / 100 / 160 / 250 / 400 / 600 bar Temperature sensitivity (zero point): 0,4% of final value/10 K Temperature sensitivity (range): 0,4% of final value/10 K Switching point: Adjustable between 0 to 100% of FS Reset point: Adjustable between 0 to 100% of FS Accuracy: √ 1,5% FS (Linearity, hysteresis, repeatability) Degree of protection to DIN 40 050: IP65 (<10bar) / IP67 (>10bar), with plug mounted Shock protection: 30g, xyz, DIN EN 60068-2-27 Vibration protection: 10g, 5 to 500 Hz, xyz, DIN EN 60068-2-6 Weight: 0,06 kg Materials Housing: aluminium, stainless steel, polyester Wetted parts: -1 to 16 bar: aluminium, ceramics, FKM (viton) 40 to 600 bar: atainless steel, ceramics, FKM (viton) All parts free of laquer impairing substances Diagnostic function acc. to DESINA Display of system pressure Easy programming of switchpoints Economic solution for industrial applications Switching status indicated by 3-colour LED display Free of laquer impairing substances Ordering information See page 2 Electrical information See page 2

description

05 602 PS10EX Pressure Switch (Ex-pro

Transcript of en_5.11.37105 602 PS10Switch (Ex-proof)

  • 4/04 N/UK 5.11.371.01Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

    33LElectronic pressure switches

    Vacuum and relative pressure -1 to 600 bar

    Technical dataMedium:Gaseous, liquid, aggressive and neutral, non-combustibleElectrical connection:M 12 x 1Mounting:OptionalFluid temperature:-25C to + 80CAmbient temperature:-20C to + 80CConsult our Technical Service for use below +2C.

    Pressure range:-1 to 1 / 16 / 40 / 100 / 160 / 250 / 400 / 600 barTemperature sensitivity (zero point):0,4% of final value/10 KTemperature sensitivity (range):0,4% of final value/10 KSwitching point:Adjustable between 0 to 100% of FSReset point:Adjustable between 0 to 100% of FSAccuracy: 1,5% FS(Linearity, hysteresis, repeatability)Degree of protection to DIN 40 050:IP65 (10bar), with plug mountedShock protection:30g, xyz, DIN EN 60068-2-27Vibration protection:10g, 5 to 500 Hz, xyz, DIN EN 60068-2-6Weight:0,06 kg

    MaterialsHousing: aluminium, stainless steel, polyesterWetted parts:-1 to 16 bar: aluminium, ceramics, FKM (viton)40 to 600 bar: atainless steel, ceramics, FKM (viton)All parts free of laquer impairing substances

    Diagnostic function acc. to DESINA

    Display of system pressure

    Easy programming of switchpoints

    Economic solution for industrial applications

    Switching status indicated by 3-colour LED display

    Free of laquer impairing substances

    Ordering informationSee page 2

    Electrical informationSee page 2

  • 4/04N/UK 5.11.371.02

    33L

    Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

    Ordering informationElectronic pressure switch, pressure range 0 to 16 bar, fluid connection G 1/4 femalequote: 00886600113300

    08601

    Fluid connection SubstituteG1/4 0Flange 6

    Pressure ranges (bar) Substitute-1 ... 1 10 ... 10 20 ... 16 30 ... 40 40 ... 100 50 ... 160 60 ... 250 70 ... 400 80 ... 600 9

    Electrical connection: M12 x 1Power supply: UB =18 to 32 V d.c., polarity safePermissible residual ripple: 10% (within UB)Current consumption: < 100 mA (plus load current)Switching mode: PNP, Potential-bound open collector switching to UBOutput signal: Out 1: switching: UB minus 1.5V / Imax. 250 mA

    Out 2: diagnostic/switching UB minus 1,5V/250 mASurge and short-circuit protection (Out1/Out2)

    Switching logic Out 1 & 2: NO/NC programmableResponse time: < 10 msService life: min. 50 million switching cyclesElectromagnetic compatibility: Interference emission acc. to EN 61326

    Interference immunity acc. to EN 61326 Part 1

    NORGREN None Bar** NO 50% 48% DESINA (NC) 2% Yellow 50%

    Setting

    * OUT 2 function is programmable: diagnostic acc. to DESINA /switching** p.s.i. on request

    Code Pressure unit OUT 1Switching logic(NO/NC)

    Switch point (% of range)

    Reset point (% of range)

    Switch point (% of range)

    Reset point (% of range)

    OUT 2*Switching logic(NO/NC)

    Displayzero point suppression(% of range)

    Colour Brightness

    Factory setting

    Electrical information

    -1 ... 1 bar 6 G1/4 2 x PNP 0,01 0860110-1 ... 1 bar 6 Flange 2 x PNP 0,01 08601160 ... 10 bar 25 G1/4 2 x PNP 0,05 08601200 ... 10 bar 25 Flange 2 x PNP 0,05 08601260 ... 16 bar 40 G1/4 2 x PNP 0,1 08601300 ... 16 bar 40 Flange 2 x PNP 0,1 08601360 ... 40 bar 100 G1/4 2 x PNP 0,2 08601400 ... 40 bar 100 Flange 2 x PNP 0,2 08601460 ... 100 bar 175 G1/4 2 x PNP 0,2 08601500 ... 100 bar 175 Flange 2 x PNP 0,2 08601560 ... 160 bar 280 G1/4 2 x PNP 1,0 08601600 ... 160 bar 280 Flange 2 x PNP 1,0 08601660 ... 250 bar 400 G1/4 2 x PNP 1,0 08601700 ... 250 bar 400 Flange 2 x PNP 1,0 08601760 ... 400 bar 700 Flange 2 x PNP 2,0 08601860 ... 600 bar 1000 G1/4 2 x PNP 3,0 08601900 ... 600 bar 1000 Flange 2 x PNP 3,0 0860196

    Pressure range (bar)# Max. value (bar)## Fluid connection* Output signal** Display step size (bar) Model

    * Versions with fluid connection 1/4 NPTF on request, versions with bleeder screw on request** Mode of OUT2 is programmable: Diagnostic acc. to DESINA / switching, switching logic of OUT1 and /OUT2 is programmable (NO/NC)# Versions with pressure unit psi on request## Max. value = over pressure. Short-term pressure peaks are not allowed to exceed this limit value during operation.Operative utilization of the overload range is not permitted.

    Options selector

  • 4/04N/UK 5.11.371.03

    33L

    Our policy is one of continued research and development. We therefore reserve the rightto amend, without notice, the specifications given in this document.

    M12x1 25

    19,5

    70

    82,8

    20

    5,5

    7,5

    1

    3

    2

    30

    30

    3 2

    54 1

    M12x1 25

    19,5

    70

    82,8

    20

    5,5

    7,5

    30

    30

    3 2

    54 1

    1,2

    8

    3

    2

    3

    2

    1 G1/4, 12 deep or 1/4 NPT, 10 deep

    LED Out 2 (on/off)

    Bleeder screw on request

    5

    14

    23

    1 +U Brown2 Out 2 (diagnostic /switch, PNP) White Red blinking / LED3 0 V Blue4 Out 1 (switch, PNP) Black Yellow / green 5 NC

    Warning

    These products are intended for use in industrial compressed airsystems only. Do not use these products where pressures andtemperatures can exceed those listed under Technical Data.

    Before using these products with fluids other than those specified, fornon-industrial applications, life-support systems, or other applicationsnot within published specifications, consult NORGREN.

    Through misuse, age, or malfunction, components used in fluid powersystems can fail in various modes.

    The system designer is warned to consider the failure modes of allcomponent parts used in fluid power systems and to provide adequatesafeguards to prevent personal injury or damage to equipment in theevent of such failure.

    System designers must provide a warning to end users in thesystem instructional manual if protection against a failure modecannot be adequately provided.

    System designers and end users are cautioned to review specificwarnings found in instruction sheets packed and shipped with theseproducts.

    Accessories

    0574767 0574773 0799845 (2 m cable length) 0523058 (2 m cable length) 0523056 (without cable) 0523057 (2 m cable length) 0523055 (without cable)0250081 (5 m cable length) 0523053 (5 m cable length) 0523052 (5 m cable length)

    Pressure portreducing nipple

    Snubber Connector M 12x1905 pins (on PE-requirement)

    Connector M 12x1904 pins

    Connector M 12x1Straight4 pins

    Electrical connection M 12 x 1

    Electrical connection M12 x 1Pin no. Signal Cable

    Display

    Accessories

    Pressure portreducing nippleMaterial: brassModel: 0574767Material: stainless steel(1.4301)Model: 0550083

    G 1/4 A

    G 1/2 A

    3143

    22

    SnubberMaterial: brassModel: 0574773Material: stainless steel(1.4301)Model: 0553258

    G 1/4 A

    3446

    G 1/421,5

    22