Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The...

66
Emittance Measurements Accelerator Beam Diagnostics Uli Raich (CERN) USPAS and University of New Mexico Albuquerque NM, June 23-26, 2009 USPAS09 at UNM 1 Accelerator and Beam Diagnostics

Transcript of Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The...

Page 1: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Emittance Measurements

Accelerator Beam DiagnosticsUli Raich (CERN)

USPAS and University of New Mexico Albuquerque NM, June 23-26, 2009

USPAS09 at UNM 1Accelerator and Beam Diagnostics

Page 2: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Contents

• What is Emittance and why measure it?

• Introduction to phase space

• Emittance in a circular machine

• Phase space scans

– Slit & grid, single shot phase space scan

– Pepperpot & screens

• 3 Profile measurement and Quadrupole scan

• Why measure Twiss parameters? Optical mismatch

• Longitudinal phase space scan

• Longitudinal phase space reconstruction with tomography

Page 3: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

What is “Emittance” ?

USPAS09 at UNM 3Accelerator and Beam Diagnostics

A beam is made of many, many particles,

each one of these particles is moving with

a given velocity. Most of the velocity

vector of a single particle is parallel to the

direction of the beam as a whole (s).

There is however a smaller component of

the particles velocity which is

perpendicular to it (x or y).

yyxxssparticle uvuvuvv ˆˆˆ

Page 4: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Transverse Phase Space

• The emittance describes the beam quality, assuming linear behavior due to second order differential equation.

• It is defined as the area in phase space including the particles (generally an ellipse).

• The measurements are base on beam width and angular width measurements at a single location or multiple measurements of beam width with additional optics calculations.

USPAS09 at UNM 4Accelerator and Beam Diagnostics

A

dxdx'1

Page 5: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

USPAS09 at UNM 5Accelerator and Beam Diagnostics

Variation of the ellipse along the transport line

Page 6: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Ellipse Parameters

USPAS09 at UNM Accelerator and Beam Diagnostics 6

Beam ellipse and its orientation is defined

by the beam matrix for which the emittance is

which is related to the Twiss or Courant-Snyder parameters:

The equation of the beam ellipse is:

22 ''2 xxxx

2212

1211

A

21

beam half widthbeam half divergencecorrelation between x and x’

α> 0 : beam is convergingα < 0 : beam is divergingα = 0 : beam has minimum or maximum

2

121211

Page 7: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

• Transverse phase space:

– x,x’ (x-position, angle in horizontal plane)

– y,y’ (y-positon, angle in vertical plane)

• Longitudinal phase space

– E, Ф (Energy and phase or time of arrival)

USPAS09 at UNM 7Accelerator and Beam Diagnostics

6-dimensional Phase Space

Page 8: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Transport of a single particle along a transfer line

USPAS09 at UNM Accelerator and Beam Diagnostics 8

Thin lens approximation:

1

01

KM quadrupole

Page 9: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

USPAS09 at UNM 9Accelerator and Beam Diagnostics

Adiabatic damping

Page 10: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

USPAS09 at UNM 10Accelerator and Beam Diagnostics

Why measure Emittance?

Page 11: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

USPAS09 at UNM 11Accelerator and Beam Diagnostics

Why measure Emittance?

Page 12: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

In a Synchrotron the lattice functions are fixed,

beam width and emittance are related:

and

The β function and the Dispersion function D are known or measured with other means

USPAS09 at UNM 12Accelerator and Beam Diagnostics

How to measure Emittance?

2

2 )()(

1

p

psD

sx

x

x

)(

2

sy

y

y

Page 13: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Wire Scanners

A thin wire is quickly moved across the beamSecondary particle shower is detected outside the vacuum chamberon a scintillator/photo-multiplier assembly Position and photo-multiplier signal are recorded simultaneously

USPAS09 at UNM 13Accelerator and Beam Diagnostics

Page 14: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Wire scanner profile

High speed neededbecause of heating.

Adiabatic damping

Current increases due tospeed increase

Speeds of up to 20m/s200g acceleration

Measure secondary particles outside thevacuum chamber orsecondary emission

USPAS09 at UNM 14Accelerator and Beam Diagnostics

Page 15: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

The Slit and Grid method

• If we place a slit into the beam we cut out a small vertical slice of phase space

• Converting the angles into position through a drift space allows to reconstruct the angular distribution at the position defined by the slit

x’

x

slit

15USPAS09 at UNM Accelerator and Beam Diagnostics

Page 16: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Transforming angular distribution to profile

• When moving through a drift space the angles don’t change (horizontal move in phase space)

• When moving through a quadrupole the position does not change but the angle does (vertical movein phase space)

x’

x

slit

x’

x

slit

x’

x

slit

Influence of a drift space

Influence of a quadrupole

USPAS09 at UNM 16Accelerator and Beam Diagnostics

Page 17: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Secondary Emission Grids

USPAS09 at UNM 17Accelerator and Beam Diagnostics

Page 18: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

SEMGrid electronics

Page 19: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

The Slit and Grid Method

Accelerator and Beam DiagnosticsUSPAS09 at UNM 19

Page 20: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Moving slit emittance measurement

• Position resolution given by slit size and displacement

• Angle resolution depends on resolution of profile measurement device and drift distance

• High position resolution → many slit positions → slow

• Shot to shot differences result in measurement errors

USPAS09 at UNM 20Accelerator and Beam Diagnostics

Page 21: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Transverse emittance line

Kicker QuadrupoleQuadrupole

SEMGridX’

X

X’

X

X’

X

X’

X

X’

X

at slit after 1. drift space after 1. quadrupole after 2. quadrupoleafter 2. drift space

Kicker

USPAS09 at UNM 21Accelerator and Beam Diagnostics

Page 22: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Single pulse emittance measurement

Kickersslit

SEMgrid

Every 100 nsa new profile

Quadrupole Quadrupole

22USPAS09 at UNM Accelerator and Beam Diagnostics

Page 23: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Result of single pulse emittance measurement

23USPAS09 at UNM Accelerator and Beam Diagnostics

Page 24: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Single Shot Emittance Measurement

Advantage: Full scan takes 20 μs

Shot by shot comparison possible

Disadvantage:Very costly

Needs dedicated measurement line

Needs a fast sampling ADC + memory for each wire

Cheaper alternative:Multi-slit measurement

24USPAS09 at UNM Accelerator and Beam Diagnostics

Page 25: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Accelerator and Beam Diagnostics

Multi-slit measurement

Needs high resolution profile detector

Must make surethat profilesdon’t overlap

beam

Scintillator + TV + frame grabberoften used as profile detector

Very old idea, was used with photographic plates

25USPAS09 at UNM

Page 26: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Pepperpot

Uses small holes instead of slits

Measures horizontal and vertical emittance in a single shot

26USPAS09 at UNM Accelerator and Beam Diagnostics

Page 27: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

USPAS09 at UNM 27Accelerator and Beam Diagnostics

Photo of a Pepperpot Device

Page 28: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Accelerator and Beam Diagnostics 28

Scintillating Screens

Method already applied in cosmic ray experiments

• Very simple

• Very convincing

Needed:

• Scintillating Material

• TV camera

• In/out mechanism

Problems:

• Radiation resistance of TV camera

• Heating of screen (absorption ofbeam energy)

• Evacuation of electric charges

Page 29: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Accelerator and Beam Diagnostics

29

Frame grabber

• For further evaluation the video signal is digitized, read-out and treated by program

• In new cameras digitization is done within the camera and digital image information is accessed via Ethernet or USB

-10 -5 0 5 10 15 20 25 30 35

0

5000

10000

15000

20000

25000

30000

35000

Inte

nsity (

u.a

.)

Y (mm)

-10 0 10 20 30 40 50 60 70

0

5000

10000

15000

20000

Inte

nsity (

u.a

.)

X (mm)

USPAS09 at UNM

Page 30: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Accelerator and Beam Diagnostics

30

Test for resistance against heat-shock

-10 0 10 20 30 40

0.1

1

10

100

1000

10000

Test start

+2min

+3min

+1h30

+3h

Lig

ht

inte

nsity (

u.a

.)

Y (mm)

-10 0 10 20 30

10000

20000

30000

40000

50000

Start

90C (30min)

450C (2h30min)

585C (3h15min)

720C (4h)

Lig

ht

inte

nsi

ty (

u.a

.)

Y (mm)

Material

r

g/cm3

cp at 20ºC

J/gK

k at 100ºC

W/mK

Tmax

ºC

R at 400

ºC

Ω.cm

Al2O3 3.9 0.9 30 1600 1012

ZrO2 6 0.4 2 1200 103

BN 2 1.6 35 2400 1014

Better for electrical conductivity (>400ºC)

Better for thermal properties

(higher conductivity, higher heat capacity)

USPAS09 at UNM

Page 31: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Accelerator and Beam Diagnostics

31

Degradation of screen

Degradation clearly visibleHowever sensitivity stays essentially the same

USPAS09 at UNM

Page 32: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Properties of scintillating material

Page 33: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

33

Screen mechanism

• Screen with graticule

USPAS09 at UNM Accelerator and Beam Diagnostics

Page 34: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

• To determine ε, β, α at a reference point in a beamline one needs at least three w measurements with different transfer matrices between the reference point and the w measurements location.

• Different transfer matrices can be achieved with different profile monitor locations, different focusing magnet settings or combinations of both.

• Once β, α at one reference point is determined the values of β, α at every point in the beamline can be calculated.

• Three w measurements are in principle enough to determine ε, β, α• In practice better results are obtained with more measurements. • However, with more than three measurements the problem is over-

determined. • χ2 formalism gives the best estimate of ε, β, α for a set of n

measurements wi i=1-n with transfer matrix elements ci, si.

USPAS09 at UNM 34Accelerator and Beam Diagnostics

3 Profile Measurement and Quadrupole Scan

Page 35: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

USPAS09 at UNM 35Accelerator and Beam Diagnostics

3-Profile Measurement

Page 36: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

• Measure 3 profiles at 3 positions around a waist

• Spot width corresponds to vertical lines

• Transform back to the first Profile

• Lines become tangents to the beam ellipse

USPAS09 at UNM 36Accelerator and Beam Diagnostics

3-Profile Measurement

x’

x

x’

x

x’

x

Page 37: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

USPAS09 at UNM 37Accelerator and Beam Diagnostics

An example from CERN PS

Page 38: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

• Works the same way as the 3-Profile measurement

• The profile is taken at a fixed position (needs a single profile measurement system)

• Vary a quadrupole and measure the profile width for each quadrupole setting

USPAS09 at UNM 38Accelerator and Beam Diagnostics

Quadrupole Scan

Page 39: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

USPAS09 at UNM 39Accelerator and Beam Diagnostics

Quadrupole Scan at CTF-3

Page 40: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Optical Mismatch at Injection

x

x’

Matched phase-space ellipse

Mismatched injected beam

• Can also have an emittance blow-up through optical mismatch

• Individual particles oscillate with conserved CS invariant:

ax = x2 + 2 xx’ + x’2

USPAS09 at UNM 40Accelerator and Beam Diagnostics

Page 41: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Optical mismatch at injection• Injected beam of emittance , characterised by a different ellipse (*,

*) to matched ellipse (, ) generates (via filamentation) a large ellipse

with original shape (, ) but larger

x

x’

After filamentation

x

x’

After filamentation

Matched ellipse determines beam shape

Turn 1 Turn 2

Turn 3 Turn n>>1

USPAS09 at UNM 41Accelerator and Beam Diagnostics

Page 42: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

X

'X

Filamentation

USPAS09 at UNM 42Accelerator and Beam Diagnostics

Page 43: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

X

'X

Filamentation

USPAS09 at UNM 43Accelerator and Beam Diagnostics

Page 44: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

X

'X

Filamentation

USPAS09 at UNM 44Accelerator and Beam Diagnostics

Page 45: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

X

'X

Filamentation

USPAS09 at UNM 45Accelerator and Beam Diagnostics

Page 46: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Filamentation

X

'X

USPAS09 at UNM 46Accelerator and Beam Diagnostics

Page 47: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

X

'X

Filamentation

USPAS09 at UNM 47Accelerator and Beam Diagnostics

Page 48: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

X

'X

Filamentation

USPAS09 at UNM 48Accelerator and Beam Diagnostics

Page 49: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

X

'X

Filamentation

USPAS09 at UNM 49Accelerator and Beam Diagnostics

Page 50: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

X

'X

Filamentation

USPAS09 at UNM 50Accelerator and Beam Diagnostics

Page 51: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

X

'X

Filamentation

USPAS09 at UNM 51Accelerator and Beam Diagnostics

Page 52: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Ionisation Profile MonitorUses rest gas in the vacuum

which is ionized.

Page 53: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Image Intensifier

Page 54: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Result from IPM

Page 55: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Optical Transition Radiation

Page 56: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Synchrotron Radiation

Dipole magnet

bending radius ρ

Page 57: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Results from Synchrotron Radiation

Page 58: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Longitudinal Phase Space Transformation

CARE workshop on emittance

measurementsU. Raich CERN

AB/BI

58

E

φ

E

φ

E

φ

E

φat slit first drift space buncher second drift space

Kicker

Buncher

Spectrometer magnet

Kicker

SEMGridTransformer

• Spectrometer produces imageof slit on second slit

• second slit selects energy slice• first kicker sweep phase space over all energies

• buncher rotates energy slice in phase space

• at second spectrometer thephase distribution istransformed into anenergy distribution analyzed bythe second spectrometer

• second kicker corrects for first kick

Buncher RF

Page 59: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Longitudinal Emittance measurement

CARE workshop on emittance

measurementsU. Raich CERN

AB/BI

59

E

φ

E E

φ

Kicker

Buncher

Kicker

SEMGridTransformer

Spectrometer magnet

E

φat slit first drift space buncher second drift space

φ

Page 60: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

Photos of the line

CARE workshop on emittance

measurementsU. Raich CERN

AB/BI

60

Kicker

Buncher

Spectrometer magnet

Kicker

SEMGrid

Page 61: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

U. Raich CAS Frascati 2008

Beam Diagnostics

Computed Tomography (CT)

Principle of Tomography:• Take many 2-dimensional Images at different angles• Reconstruct a 3-dimensional pictureusing mathematical techniques(Algebraic Reconstruction Technique,ART)

Page 62: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

U. Raich CAS Frascati 2008Beam Diagnostics

The reconstruction

Produce many projections of the object to be reconstructed

Back project and overlay the “projection rays”

Project the back-projected object and calculate the difference

Iteratively back-project the differences to re-construct the original object

Page 63: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

U. Raich CAS Frascati 2008

Beam Diagnostics

Some CT resuluts

Page 64: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

U. Raich CAS Frascati 2008

Beam Diagnostics

Computed Tomography and Accelerators

RF voltage

Restoring force for non-synchronous particle

Longitudinal phase space

Projection onto Φ axis corresponds to bunch profile

Page 65: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

U. Raich CAS Frascati 2008

Beam Diagnostics

Reconstructed Longitudinal Phase Space

Page 66: Emittance Measurements - USPASuspas.fnal.gov/materials/09UNM/Emittance.pdf · ellipse). • The measurements are base on beam width and angular width measurements at a single location

U. Raich CAS Frascati 2008

Beam Diagnostics

Bunch Splitting