Emissions Measurements from the Golden Vehicle – A Light ... · PDF fileSession 1:...
Transcript of Emissions Measurements from the Golden Vehicle – A Light ... · PDF fileSession 1:...
17th CRC ON-ROAD VEHICLE EMISSIONS WORKSHOP
San Diego, California
March 26-28, 2007
Session 1: Diesel Vehicle Emissions
Emissions Measurements from the Golden Vehicle –
A Light Duty Diesel Vehicle Used During Validation of the European PMP
Protocol
Alberto Ayala, Sherry Zhang, Bruce Frodin, Jorn Herner, and Whitney LeemanCalifornia Air Resources Board
Tim Johnson
TSI, Inc.
Qiang Wei
• European Union – Directorate General – Joint Research Center (JRC), Ispra, Italy. Dr. Penny Dilara and many others
• Dr. Tao Huai, Ronald Haste, Sharon Lemieux, Wayne McMahan, Paul Rieger, and many other members of CARB’s technical staff
• Dr. Tom Durbin and others at UCR/CE-CERT
• Dr. Markus Kasper/Matter Engineering AG
• Jon Andersson/Ricardo UK Ltd
Acknowledgements
CARB’s Research Portfolio on Ultrafine Particle Emissions from
Mobile SourcesCARB PMP-based Program on LDDV (Golden Vehicle)
HDDV PMP Study
CARB/CE-CERT
Extensive Domestic and International Collaboration
Measurement Instrument Evaluation
Sampling Methodology
Investigation of Nature and Relative Toxicity of
Emissions
• CARB/SCAQMD/USC/UCLA
• Inform ACES
Investigation of multiple engine/aftertreatment
technology
LDGV PM Study
CARB/CE-CERT/ESP/DRI
Investigations:
• Laboratory
• on-road
• chase vehicle
• In-vehicle
Extramural Research
In-house Investigation
Comparison of PM mass,
number, other metrics
Portable and fixed systems
• Potential health impacts of ultrafine particles
• CARB and JRC Memorandum of Understanding (MOU) for Research
• Need to understand the potential of the new European proposal for particle # emission standard
� Assess robustness of PMP Protocol vis a vis gravimetric measurement� Evaluate non-specified particle counters, alternative systems, and dilution methods
• CARB is exploring PMP’s utility and “enriching the main programme” for LDVsand HDVs
• Investigate nature of particles emitted at the tailpipe and their relative toxicity
CARB PMP-based ProgramStudy Drivers
UNECE-GRPE Particulate Measurement Programme (PMP)
• Initiating governments: France, Germany, Netherlands, Sweden, & UK. Joined by Switzerland, Japan, and Korea
• Key objective: “Development of type approval test protocols for assessing vehicles fitted with advanced particulate reduction technology that would complement or replace current legislative measurement procedures”
• Main driver behind PMP is the impact of particles on health
• Key objective is development of new particle measurement technique for very low emission levels
• Inform EU Directives: LDV EURO5 and HDV EURO6
1) M. Dunn, UK Depart. Of Transport, ETH Nanoparticles Conference, 2003, Zurich
2) Andersson et al., PMP Light-duty Inter-Laboratory Correlation Exercise Final Report, GRPE-PMP-18-2, Mar.2007
Sources:
UNECE-GRPE PMP – cont’d• Phase 1 – instrument comparison (mass, number, surface,
chemistry, dilution, sample conditions, cost, ease of use, etc)
• Phase 2 – More rigorous evaluation of best performing systems. Conclusions were,
� An improved filter-based method based on US07� A particle number method based on counting, dilution, and thermal
treatment to eliminate volatile particles
• Phase 3 – Inter-Laboratory Correlation Exercises (ILCE)
• 9 international laboratories (Europe, Japan, Korea) + California
• 17 vehicles (Euro 4), including GV (“transfer standard”)
• CARB testing of GV is on-going (Jan 07 – present)
Source: Andersson et al., PMP Light-duty Inter-Laboratory Correlation Exercise Final Report, GRPE-PMP-18-2, Mar.2007
HDV PMP Project
OVER-THE-ROAD TESTS
Univ. of Calif. Riverside Mobile Emissions Laboratory
CVS SAMPLING POINT
PRE-CVS SAMPLING POINT
EMISSIONS LABORATORY TESTS
CARB Heavy Duty Vehicle Emissions CARB Heavy Duty Vehicle Emissions Laboratory, Los AngelesLaboratory, Los Angeles
PMP Protocol Exhaust
Primary dilution, 150ºC
Secondary Dilution
CPC
3010D
Evaporation Tube, 300ºC
Volatile Particle Remover (VPR)
PMP
Static Dissipative Tubing
Pre classifier
Heavy-duty Vehicle Testing
• Extensive testing to data (CRC ’06)
• Applying PMP protocol for pre-and at CVS sampling
• California DPF-equipped truck
� 2000 Isuzu MHD truck (8.3L, 22K lbs)
� JMI’s CRT
• CARB’s Heavy-duty Vehicle Emissions Laboratory
• Various US transient duty cycles and steady-state operation
• PMP testing in 2006 and 2007
Particle number measurements are considerably more precise than the mass measurement in the current study
Upcoming improvements in gravimetric measurements at CARB labs are expected to get closer to new US07 1065 Rule
Particle Number and Mass EmissionsCBD
0.E+00
1.E+12
2.E+12
3.E+12
4.E+12
PMP From CVS Mass
Par
ticle
s/m
i
0.0
2.5
5.0
7.5
10.0
mg/
mi
Particles per Mile [lhs]
Mass per mile [rhs]
N=7 N=7
N=17
HDV Emission Measurement Comparison
Source: Herner, Robertson, and Ayala, SAE Technical Paper 2007-01-1114
Cumulative Normalized Average Size Distribution*Post Trap Measurements
0.0
0.2
0.4
0.6
0.8
1.0
1 10 100 1000
Particle Size (nm)
Idle
Cruise
CBD
*Measured with EEPS
Evaporation Tube 300ºC
“ Solid” particles can be smaller than 23nm ( PMP D50 cut)
Idle
CBD
23nm
PMP
Cruise
Recent Tunnel Blanks - 3025 PMP
1
10
100
1000
- 5 10 15 20 25 30 35 40Elapsed Time [min]
#/cc
1/25/07 at 7:55
1/25/07 at 15:05
1/26/07 at 6:48
1/26/07 at 13:35
2/7/07 at 10:25
2/8/07 at 6:50
2/9/07 at 6:47
Testing has not been problem-free
One example
HIGH TUNNEL BLANK
� Lubricating coating on rotating disk and diluter head can quickly degrade and ware off� Once the coating starts to break apart, the instrument appears to generate particles � It may be preferable to operate the instrument at 80°C or 120°C to avoid wearing off the
coating when operating at 150 °C
European Gold descending on California
Golden Vehicle
Golden Engineer
Golden System
PMP’s Golden Vehicle – Euro 4 Peugeot 407 Saloon 2.0 H Di 136 SE equipped with an uncoated diesel particulate filter and ceri um based fuel borne catalyst
• Testing at one of CARB’s clean light-duty vehicle em issions laboratories with CA ULSD
• Pre-conditioning effects
• FTP, NEDC, and steady-state operation
• SHED testing for evaporative emissions
• Testing Jan – Mar 2007 (on-going )
Preliminary Results for Golden Preliminary Results for Golden VehicleVehicle
Golden Vehicle Testing -Instrumentation
TSI 3790
TSI EEPS
Particle Counters
Diluter
Matter Engineering MD-19
TSI 3010D Grimm CPC
EcoChem PAS2000 Matter Engineering LQ1-DC
Horiba SPCSHoriba SPCS
Average Mass Emissions during NEDC for Au VehiclePreliminary CARB Results
0
0.2
0.4
0.6
0.8
1
1.2
THC (*10) CO CO2 (/1000) NOx PM (*1000)
Pollutants
Ave
rage
Em
ission
s (g
/km
) CARBAu-DV1
Particle Number Emissions during NEDC Au Vehicle (e xcluding regeneration) Horiba SPCS
0
2E+10
4E+10
6E+10
8E+10
1E+11
1.2E+11
1-NEDC-8 1-NEDC-10 Mean Au-Veh
Tests
Par
ticle
Em
ission
s (#
/km
)
Preliminary
Results
*EEPS average over entire NEDC
Particle Size Distribution (1-NEDC-10, 02MAR07)*Au Vehicle
1
10
100
1000
1 10 100 1000
Particle size (nm)
Par
ticle
con
cent
ratio
n (#
/cc)
Average Particle Size Distribution, NEDC, Mar 02, 2 007 - Au Vehicle
1
10
100
1000
10000
1 10 100
Particle Size (nm)
Par
ticle
Con
cent
ratio
n (N
/cm
^3)
9:50 AM9:55 AM10:00 AM10:05 AM10:10 AM
0.00E+00
4.00E+07
8.00E+07
1.20E+08
1.60E+08
2.00E+08
10:04:48 AM 10:13:26 AM 10:22:05 AM 10:30:43 AM 10:39:2 2 AM 10:48:00 AM
Time (Sec)
Tun
nel C
ount
Regeneration achieved as expected
0
20
40
60
80
100
120
7000 7500 8000 8500 9000 9500 10000
Time (Sec)
CO
and
CO
2 E
mis
sion
s (%
)
0
5000
10000
15000
20000
25000
30000
NO
x E
mis
sion
s (p
pm)
NOx
CO
CO2
Summary• Study of Au-Veh is on-going, no final interpretations or conclusions yet
• But our findings to date are very encouraging. Preliminary results are consistent with those of 9 other international laboratories
• Gaining important experience with PMP protocol, its potential, and new opportunities for use in California
• Enhancing understanding of nature of ultrafine particle emissions
• PMP project is giving important exposure to light-duty diesel vehicle technology
• From HDV testing:
– The PMP particle number measurements are more precise than gravimetric measurements
– There are sub-23nm solid particles post PMP sampling that can be counted with equal accuracy as those >23 nm
• On track to complete study successfully by mid-2007