Emergency Shutdown system ESD - MPL Techma · The main task of the Emergency Shutdown system ESD is...

4
www.mpltechma.pl Copyright 2015 by MPL Techma Ltd Maritime Department Emergency Shutdown system ESD

Transcript of Emergency Shutdown system ESD - MPL Techma · The main task of the Emergency Shutdown system ESD is...

Page 1: Emergency Shutdown system ESD - MPL Techma · The main task of the Emergency Shutdown system ESD is to secure the shutdown function and control of specified devices and signaling

www.mpltechma.plCopyright 2015 by MPL Techma Ltd

Maritime Department

Emergency Shutdown system ESD

Page 2: Emergency Shutdown system ESD - MPL Techma · The main task of the Emergency Shutdown system ESD is to secure the shutdown function and control of specified devices and signaling

Maritime Department

www.mpltechma.plCopyright 2015 by MPL Techma Ltd

The main task of the Emergency Shutdown system ESD is to secure the shutdown function and control of specified devices and signaling of alarm in case of gas det-edtion or other situations potentially dangerous for a ship equipped with LNG fu-elled main and auxiliary propolusion.

In case of emergency, depending on its cause, the system interacts with a suitable algorithm for each device by:

• Switch off: – Specified switchboard section eg. ventilation supply section – Main engine or auxiliary engine – UPS power supplier which supply specified devices

• Control: – Fuel system shut off valves

• Indication: – Alarm states on ESD system alarm panel – Alarm states to engine room monitoring system – ESD system switchboard self-diagnostic signals to engine room monito-

ring system

The ESD system is a redundant system . In case of single PLC or operator pan-el failure, the control task is automatically switched to second PLC. The control changeover is driven uninterrupted.

Each measuring input channel has a failure self-diagnosis of mesure sensor and measurement line cable .

MPL Techma provides the opportunity to develop a system both for newly built vessels as well as a retro-fits of old systems . We also provide service and mainte-nance of existing systems.

Page 3: Emergency Shutdown system ESD - MPL Techma · The main task of the Emergency Shutdown system ESD is to secure the shutdown function and control of specified devices and signaling

Emergency Shutdown system ESD

www.mpltechma.plCopyright 2015 by MPL Techma Ltd

Page 4: Emergency Shutdown system ESD - MPL Techma · The main task of the Emergency Shutdown system ESD is to secure the shutdown function and control of specified devices and signaling

www.mpltechma.plCopyright 2015 by MPL Techma Ltd

MPL Techma Ltd96/98 Al. Zwycięstwa str.81-451 Gdynia, POLAND

[email protected]

We cooperate with:

We fulfill the requirements of the leading classification societies:

Maritime Department