Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa...

31
Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics 1

Transcript of Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa...

Page 1: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Effectiveness of Linear Spray Cooling in Microgravity

Presented by

Ben Conrad, John Springmann, Lisa McGill

Undergraduates, Engineering Mechanics & Astronautics

1

Page 2: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Heat dissipation requirements

• Remove heat fluxes of 100-1000 W/cm2

• Applicable to laser diodes, computer processors, etc.

Laser Diode Array(Silk et al, 2008)

2

Page 3: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Heat dissipation requirements

• Current Solutions– Flow boiling– Microchannel boiling– Jet impingement– Spray cooling

Spray cooling is the most promising because it achieves high heat transfer coefficients at low flow rates.

3

Page 4: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Limited previous microgravity research

• Yoshida, et al. (2001): single spray perpendicular to heated surface (100 mm away)

Microgravity significantly effects critical heat flux

14% variation in the critical heat flux from 0 to 1.8 Gs

• Sone et al. (1996): single spray perpendicular to heated surface (100 mm away)

• Golliher, et al. (2005): single spray angled 55⁰ in 2.2 sec. drop tower Significant pooling on the heated surface due largely to surface tension

4

Noted a decrease in Nusselt number with acceleration

• Yerkes et al. (2004): single spray in micro- and enhanced-gravity.

Page 5: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Spray cooling – linear array

• Single-spray systems do not cover a large area (> 1 cm2)• Regner and Shedd investigated a linear array of sprays

directed 45o onto a heated surface

• Directs fluid flow towards a defined exit to avoid fluid management issues

5

(Shedd, 2007)

Page 6: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Experiment basis & hypothesis

(Regner, B. M., and Shedd, T. A., 2007)

6

Linear spray research showed performance independent of orientation

Page 7: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Experiment basis & hypothesis

Predict that with similar spray array, spray cooling will function independent of gravity

7

Page 8: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Experiment design

Goal: determine variation of heat transfer coefficient h with gravity

q’’: heat flux measured from heater powerTs: Temperature of heated surfaceTin: Temperature of spray

8

Page 9: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Closed-loop systemPump Flow Meter

Pressure SensorBladder

Filter 3 Axis Accelerometer

Spray Box

Heat Exchanger

Pressure Sensor

Differential Pressure Sensor

Therm.

Therm.

Therm.

Therm.

Liquid coolant: FC-72

9

Page 10: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Heater design

• Ohmite TGHG 1 Ω precision current sense resistor • Four T-type thermocouples embedded in heater

25.4 mm

8.0 mm

10

Page 11: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Spray array design

Shedd, 2007

Made from microbore tubing:

11

3.2 cm

Page 12: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Spray array & spray box

12

Top half: spray array

Bottom half: heater

G

Z-direction

Fluid inlet & outlet

Page 13: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Microgravity environment

• 30 microgravity (nominally 0 g) parabolas lasting 20-25s each

• 1.8 g is experienced between microgravity

13

Page 14: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Microgravity environment

14

Page 15: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Procedure: Flow rate Q & heat flux q”

Q (L/min):0.672.673.81

15

q” (W/cm2):24.9 25.8 26.6

Very conservative heat fluxes used due to experimental nature

Page 16: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Epoxy seal failure

Epoxy cracked due to fluid pressure in pre-flight testing

Spray Array

Drain

Epoxy Failure

3.2 cm

16

Page 17: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Epoxy seal failure

17

Page 18: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Visualization shows fluid behavior

Heater

Drain

18

Camera

Page 19: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Complex fluid behavior

19

Page 20: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Flight data: flow rate dominates performance

20

Page 21: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Δh is consistent with Δg for each flow rate

• h increases with microgravity• Decreases with enhanced gravity

21

Page 22: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

h vs. jerk

Increasing variability with flow rate:

Flow rate: 0.67 L/min 2.67 L/min 3.81 L/min22

Possible Relationships

Page 23: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Shedd model for +/- 1 g

Shedd (2007) found a correlation of the form:

where the heat transfer coefficient, h, is a function of • the average spray droplet flux, Q”, and constants: • the fluid’s density, ρ,• specific heat, cp,

• Prandtl number, Pr, • an arbitrary constant, C in [m.5s-.5], for a linear spray array,• and a constant power, a.

23

Page 24: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Microgravity results fit trend

• Q” is believed to be 10-20% high due to the broken epoxy on the spray array

24

Page 25: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Future steps

• Effect of spray characteristics– Spray hole diameter and length– Hole entrance and exit design

• Enhanced surfaces with linear spray cooling?

Fluid Inlet

Nozzle diameter Nozzle

length

Nozzle edge type

25

(Kim, J. 2007)

Page 26: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Conclusion

• Flow rate Q largely determines h– 2.61 % standard deviation of h

• Support for a simple relation between h and Q– Ability to predict microgravity performance with a

1g test

• Unforeseen correspondence with jerk and Q

• Further microgravity studies are needed

26

Page 27: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Thanks

The authors are thankful to:

• the University of Wisconsin ZeroG Team

• the Multiphase Flow Visualization and Analysis Laboratory

• the UW Space, Science, and Engineering Center

• the UW Department of Engineering Physics

• the Wisconsin Space Grant Consortium

• NASA Reduced Gravity Student Flight Opportunities Program

27

Page 28: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

Questions

28

Page 29: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

29

Page 30: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

FEA confirms broken array & uneven cooling

FEA confirms the rupture caused uneven temperatures:

Cross-section:

Side with rupture, Side with spray cooling less cooling

Top down:

30

Page 31: Effectiveness of Linear Spray Cooling in Microgravity Presented by Ben Conrad, John Springmann, Lisa McGill Undergraduates, Engineering Mechanics & Astronautics.

31