ECCN Exclusive Product Webinar Loadcenters and …pub/@electrical/documents/conte… · ECCN...

26
© 2010 Eaton Corporation. All rights reserved. ECCN Exclusive Product Webinar Loadcenters and Circuit Breakers Monday May 2, 2011

Transcript of ECCN Exclusive Product Webinar Loadcenters and …pub/@electrical/documents/conte… · ECCN...

© 2010 Eaton Corporation. All rights reserved.

ECCN Exclusive Product WebinarLoadcenters and Circuit Breakers

Monday May 2, 2011

22© 2009 Eaton Corporation. All rights reserved.

Agenda

• Presenter Introduction

• Loadcenter Product Line

• Product Line Overview

• New Product Launches

• Breaker Product Line

• New Product Launches

• Additional Resources

• Question & Answer

33© 2009 Eaton Corporation. All rights reserved.

Presenter Information

Responsible For:

• Thermal Magnetic Circuit Breakers

• Ground Fault Circuit Interrupters

• Arc Fault Circuit Interrupters

• Industrial Circuit Breakers

• Residential Solar Inverters

Rich ElchikBreaker Product Line Manager

412-893-4653

[email protected]

Responsible For:

• Load Centers

• Metering

• Surge Products

• Power Outlet Panels

• Air Conditioning Disconnects

• Pool Panels

Jim DavidsonSteel Product Line Manager

412-893-4413

[email protected]

44© 2009 Eaton Corporation. All rights reserved.

The Industries Most Complete Product Line!

Three Options to Meet Market Needs…

1. Traditional Loadcenter

• Standard CH Loadcenter / Meter Breaker

• Surge Installed CH Panels

• Surge Ready CH Panels

• Plug-On Neutral CH Panels

2. Retrofit Interior

3. Renovation CH Panels

All Products Carry Lifetime Warranty!

55© 2009 Eaton Corporation. All rights reserved.

Your Benefits To Using CH Brand

1. Eliminate the Use of Other Brand Circuit Breakers in Your Work

• ¾” Circuit Breakers

2. Primarily Available Through Electrical Distribution

• Restricts Homeowners Ability to “Shop Around”

3. A Product That You Can Be Confident In

• 35kA Commercial Grade Main Breaker

• Silver Plated Copper Buss

• Steel Backpan

• Lifetime Warranty on ALL Parts / Pieces

4. Trip to Off Breakers Reduces Unhappy Customers

5. Universally Fed – Can be Top or Bottom!

6. Multiple Solutions For ALL Types of Jobs

66© 2009 Eaton Corporation. All rights reserved.

The Best Keeps Getting Better!!!New Product Launches

CHSP Product Family

Meets New UL Standards

Q1

3rd Edition Type 2 Surge

Industry Exclusive

Full 60 Space Panel,

Listed up to 120

Ckts

60 Circuit Loadcenter

Q2

Includes Cover that

can be painted

Communication Grounding Device w/ Cover

CH Plug-on Neutral Ground Fault

• 1P / 15 Amp, 5mA

• 1P / 20 Amp, 5mA

UL1449 3rd Edition Type 1 Surge

Installs Before or After the Main Service

Disconnect

Replaces “Lightning Arrestors” Sold Under

Previous UL Standards

Ideal for Light Commercial & OEM Applications

(up to 600V)

CH with Trip Flag Indication

• 1P up to 30 Amps

• 2P up to 30 Amps

77© 2009 Eaton Corporation. All rights reserved.

New Larger Loadcenter Now Available!

88© 2009 Eaton Corporation. All rights reserved.

60 Circuit Plug-on Neutral Loadcenter

120

Max.

Number

of

Circuits

CH8NF

Combination

Cover Catalog

Number

60200CSH

35KAIC

CH60BPN200N

Max.

Number

of

Spaces

Main

Breaker

Rating

Main

Breaker

Type

Catalog Number

• Space Savings: Increased number of circuits eliminates the need for a subpanel

• Time Savings: Plug-on neutral saves up to 25% per AFCI / GFCI installation

• Accommodates both Plug-on Neutral AFCI and new Plug-on Neutral GFCI

• Full 60 spaces – listed for up to 120 ckts

• Easy to hang trim via top keyhole mount on each side

• Additional knockoutsalong each side wall for surface installations

• Neutral bars extend the entire length of the bus

• Competitive products require the use of twinbkrs to obtain 60 ckts

For use in areas where the 2008 NEC® has been approved.

AvailableNow!

99© 2009 Eaton Corporation. All rights reserved.

CHSPT2MICROCHSPT2MAXCHSPT2ULTRA

March CHSP Product Line (UL1449 2nd Edition)

UL1449 3rd Edition Surge Product

CHSPT2 Product Line (UL1449 3rd Edition)

CHSPMICROCHSPMAXCHSPULTRA

AvailableNow!

1010© 2009 Eaton Corporation. All rights reserved.

New 3rd Edition Surge Products Feature Updated Product Overlays, Labeling, & Packaging

CHSPT23PACKCHSPCHSR4P

CHSPTELEDHW4PT

CHSPCABLEDCXCAB2

CHSPT2MICROCHSPMICRO

CHSPT2MAXCHSPMAX

CHSPT2ULTRACHSPULTRA

New Catalog NumbersOld Catalog Numbers

1111© 2009 Eaton Corporation. All rights reserved.

Power Distribution for Events

• The Application:

• Fairs

• Convention Centers

• Concerts

• The Problem:

• Unsafe

• Unsightly

• Difficult to Install

1212© 2009 Eaton Corporation. All rights reserved.

New Event Panel Provides Safe Means for Distributing Temporary Power

• Designed for quick connection and removal

• For use in Convention Centers, Street Fairs, Event Centers, etc.

• Provides Safe, Portable, Temporary Power

• Use in both 1-Phase &3-Phase applications New

Product!

1313© 2009 Eaton Corporation. All rights reserved.

ATS Ready Loadcenter

• Factory installed ATS kit

• Contactor based design

available up to 50 amps

• Accommodates the

following Eaton

Generators

• 8 kW - EGEN8

• 10 kW - EGEN10

AvailableNow!

1414© 2009 Eaton Corporation. All rights reserved.

Plug on NeutralCH Breakers and Loadcenters

Step 1: Fit breaker onto

the neutral bar.

Step 2: Snap breaker firmly

onto the bus bar.

End result is a tight fit

and clean connection.

Benefits Include:

• Time savings up to 25% per AFCI

• Eliminates nuisance tripping from loose pigtail connections

• Clean gutter space and installation

• Easier troubleshooting due to less wiring

• Backed by a lifetime warranty

Eaton has revolutionized the way that Arc Fault Circuit

Breakers are installed with the Plug On Neutral

Loadcenter and Arc Fault Circuit Breakers.

1515© 2009 Eaton Corporation. All rights reserved.

• Seven Plug-on Neutral

Loadcenters Now

Available

• GFCI Breakers Added

Plug-On Neutral Product Line Expansion!

Catalog Number / Cover:CH42BPN200K / CH8KF

CH32BPN200J / CH8JF

CH24BPN100E / CH8EF

CH42NLPN200K / CH8NLKF

CH32NLPN225J / CH8NLJF

CH24NLPN125E / CH8NLEF

CH60BPN200N / CH8NF

Breakers:CH120CAFPN CH120GFPN

CH115CAFPN CH115GFPN

NewStyles!

1616© 2009 Eaton Corporation. All rights reserved.

Plug-on Neutral GFCI

• 1 Pole Options

• CH115GFPN

• CH120GFPN

• Applications- any near water

• Bathroom

• Kitchen

• Swimming pools

• Outdoor receptacles

• Standards

• UL 943

• UL 499

AvailableNow!

1717© 2009 Eaton Corporation. All rights reserved.

Introducing The Industries Best Breaker!

• Exclusive “Trip to OFF” feature

• Simple 1-Step Reset feature

• Red flag visually indicates “Tripped” status

• ¾” Design- space savings

• Tri-Drive Screw

• Flat

• Robinson

• Phillips

• Limited Lifetime Warranty

1818© 2009 Eaton Corporation. All rights reserved.

CHF Breaker with Trip Flag

• Product will be released by end of May

• 1 and 2 pole

• 15-30 Amp ratings

• Applications

• Residential

• Light commercial

• OEM

• Standards

• UL489

• CSA 22.2 No. 5

1919© 2009 Eaton Corporation. All rights reserved.

ECCN CHF Launch Materials

The Following Information Will Be Included:

• Competitive Comparison

• Cross Reference

• Catalog Sheet

• Product Aid

• FAQ’s

All ECCN Members Will Receive an Email

Alert When the Product is Released!

2020© 2009 Eaton Corporation. All rights reserved.

Tenant Main / Enclosed – Circuit Breakers

• 10 & 22 KAIC Solutions

• CCV / CVH 2 Pole to be Released for Sale

• CCV / CCVH 3 Pole release in 4Q 2011

• 42, 65 and 100kAIC Solutions

• New CV Family to be available 3Q 2011

• 2 and 3 pole designs, including Molded Case Switch

• 60 to 225 ampere ratings

• Addresses 65 kAIC Applications where 100 kAICwere previously used

• Will expand Series Ratings capabilities

2121© 2009 Eaton Corporation. All rights reserved.

Fire Alarm Breaker

• Red handle

• Marking per NFPA 72, section 10.5

• Design options

• Plug-on

• Bolt

AvailableNow!

2222© 2009 Eaton Corporation. All rights reserved.

Fire Alarm Breaker-Selection Chart

2323© 2009 Eaton Corporation. All rights reserved.

2 Pole AFCI – Coming Soon!

• Market Need – Shared Neutral Circuits

• Installed 3 Wire Homeruns (Renovation)

• Material and Labor Savings (New Construction)

• UL Testing

• CH Passed in April 2011 – Available in May

• BR anticipated release in June 2011

2424© 2009 Eaton Corporation. All rights reserved.

Resources Available

� CH Load Center BrochurePublication # BR00301004E

� 60 Circuit LoadcenterSales Aid # PA0030105E Competitive Comparison # CC00301001E

� ATS Ready LoadcenterPublication # BR00405005E

� CHF Flag BreakerMaterials to be Provided with Product Launch

� Eaton Website (www.eaton.com)

� ECCN Website (www.eatoncertified.com)

� Dedicated Email For Product/Program Questions [email protected]

2525© 2009 Eaton Corporation. All rights reserved.

Ask The Experts…

We Will Un-mute Your Phone…

• Open Questions For 30 Minutes

• Use the “Chat” Feature on the webinar if you don’t want to talk on the phone

Ask Us A

Question!

2626© 2009 Eaton Corporation. All rights reserved.