Ecam Warning

28
 ECAM WARNING A330 1

Transcript of Ecam Warning

Page 1: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 1/28

 

ECAM WARNING A330

1

Page 2: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 2/28

 

ECAM WARNING A330

A330 L/H RESET PANEL

ACP/AMU Audio Control Panel/Audio Management UnitAEVC Avionic Equipment Ventilation Controller AEVC (2HQ)CIDS Cabin Intercommunication Data System CIDS Director (101 RH)CMC Central Maintenance Computer CMC 1 (1 TM 1 )CPC Cabin Pressure Controller CPC1 (311 HL)DMC Display Management Computer DMC1 (1WT1) DMC3 (1WT3)

EIVMU Engine Interface and Vibration Monitoring Unit EIVMU1 (1 KS1)FCDC Flight Control Data Concentrator FCDC1 (1 CE1)FCMC Fuel Control and Management Computer FCMC1 (5QM1)FCU Flight Control Unit FCU1 (3CA1)FM Flight Management Inside of FMGEC

FMGEC Flight Management Guidance Envelope Computer FMGEC 1 (1CA1)FWC Flight Warning Computer FWC1 (1WW1)LGCIU Landing Gear Control Interface Unit LGCIU1 (5GA1)Pack Control Pack Controller PC1 (531 HH)PHC Probes Heat Computer PHC1 (6DA1) PHC3 (6DA3)

PSCU Proximity Switch Control Unit PSCU1 (5MJ1)SDAC System Data Acquisition Computer SDAC1 (1WV1)SDCU Smoke Detection Control Unit SDCU1 (20WH2)

WHC Window Heat Computer WHC1 (2DG1)

2

Page 3: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 3/28

 

ECAM WARNING A330

A330 R/H RESET PANEL

ACP/AMU Audio Control Panel/Audio Management Unit

CIDS Cabin Intercommunication Data System CIDS Director (102RH)

CMC Central Maintenance Computer CMC2 (1TM2)

CPC Cabin Pressure Controller CPC2 (312HL)

DMC Display Management Computer DMC2 (1WT2)

EIVMU Engine Interface and Vibration Monitoring Unit EIVMU (1 KS2)

FCDC Flight Control Data Concentrator FCDC2 (1 CE2)

FCMC Fuel Control and Management Computer FCMC2 (SOM2)

FCU Flight Control Unit FCU2 (3CA2)FM Flight Management Inside of FMGEC

FMGEC Flight Management Guidance Envelope Computer FMGEC 2 (1CA2)

FWC Flight Warning Computer FWC2 (1 WW2)

LGCIU Landing Gear Control Interface Unit LGCIU2 (SGA2)

Pack Control Pack Controller PC2 (S32HH)

PHC Probes Heat Computer PHC2 (6DA2)

PSCU Proximity Switch Control Unit PSCU2 (SMJ2)

SDAC System Data Acquisition Computer SDAC2 (1WV2)

SDCU Smoke Detection Control Unit SDCU2 (20WH2)

Vent Control Ventilation Controller VC (280HN)WHC Window Heat Computer WHC2 (2DG2)Zone Control Zone Controller ZC (630HK)

3

Page 4: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 4/28

 

ECAM WARNING A330

CAB PR A330

CAB PR AFT OFV NOT OPEN NO GO

-Check forward Outflow Valve OPEN 

CAB PR EXCESS CAB ALT NOT APPLICABLE

-Reset breakers CPC 1 and 2 on LH and RH reset panels  

CAB PR FWD OFV NOT OPEN NO GO

-Check aft Outflow Valve OPEN 

CAB PR LDG ELEV FAULT MEL 21-31-05

-Reset breakers CPC 1 and 2 on LH and RH reset panels  -Reset breaker DMC 3 on RH reset panel 

CAB PR LO DIFF PR NOT APPLICABLE

-No Action 

CAB PR SAFETY VALVE OPEN MEL 21-31-04

-If safety valves are visually closed: -Reset breakers SDAC 1 and 2 on LH and RH reset panel  

CAB PR SYS 1 + 2 FAULT MEL 21-31-01

-Reset breakers CPC 1 and 2 on LH and RH reset panels  

CAB PR SYS 1 FAULT MEL 21-31-01

-Reset breaker CPC 1 on LH reset panel 

CAB PR SYS 2 FAULT MEL 21-31-01

-Reset breaker CPC 2 on RH reset panel 

COND A330

COMD AFT CRG ISOL FAULT MEL 21-28-03-B-Reset breaker VENT CANT Lane 1/2 on RH reset panel 

COND AFT CRG VENT FAULT MEL 21-28-03-A

-Reset breaker VENT CANT Lane 1/2 on RH reset panel 

COND BULK CRG DUCT OVHT MEL 21-43-02

-Reset breaker VENT CANT Lane 1/2 on RH reset panel

COND BULK CRG HEAT FAULT MEL 21-43-02

-Reset breaker VENT CONT Lane 1/2 on RH reset panel

COND BULK CRG ISOL FAULT MEL 21-28-04-8

-Reset breaker VENT CONT Lane 1/2 on RH reset panel 

COND BULK CRG VENT FAULT MEL 21 28-04-A 

-Reset breaker VENT CONT Lane 1/2 on RH reset panel 

COND L + R CAB VENT FAULT MEL 21-21-01 

-Reset breaker VENT CONT Lane 1/2 on RH reset panel 

COND L CAB VENT FAULT MEL 21-21-01 

-Reset breaker VENT CONT Lane 1/2 on RH reset panel 

COND LAV+GALLEY FAN FAULT MEL21-23-01 

-Reset breaker VENT CONT Lane 1/2 on RH reset panel 

COND R CAB VENT FAULT MEL21-21-01 

-Reset breaker VENT CONT Lane 1/2 on RH reset panel 

COND VENT SYS FAULT MEL 21-26-04 

-Reset breaker VENT CONT Lane 1/2 on RH reset panel COND ZONE CTLR 1 FAULT MEL 21-63-01 

-Reset breaker ZONE CONT on RH reset panel 

4

Page 5: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 5/28

 

ECAM WARNING A330COND ZONE CTLR 2 FAULT MEL 21-63-01 

-Reset breaker ZONE CONT on RH reset panel 

COND ZONE REGUL FAULT MEL 21-63-01 

-Reset breaker ZONE CONT on RH reset panel 

VENT A330

VENT BLOWING FAULT MEL 21-21-01 or MEL 21-26-08-A 

- Reset breaker AEVC on LH reset panel 

VENT EXTRACT FAULT MEL 21-26-01 

-Reset breaker AEVC on LH reset panel 

VENT GND COOL FAULT MEL 21-27 

VENT OVBD VALVE FAULT MEL 21-26-02 

- Reset breaker AEVC on LH reset panel 

VENT PACK BAY VENT FAULT MEL 21-25

- Reset breaker AEVC on LH reset panel 

AIR A330

AIR ABNORM BLEED CONFIG MEL 36-11-01 

-Operational message...No further action required. 

AIR APU BLEED FAULT MEL 36-12-02

-Perform Bite Test of BMC 1 and 2 on MCDU (ATA 36)  

AIR APU BLEED LEAK MEL 36-12-01 

-Perform Bite Test of BMC 1 and 2 on MCDU (ATA 36)  

AIR BLEED LO TEMP MEL 36-11-01 -Perform Bite Test of BMC 1 and 2 on MCDU (ATA 36)  

AIR BMC 1 + 2 FAULT MEL 36-11-01 

-Perform Bite Test of BMC 1 and 2 on MCDU (ATA 36)  

AIR BMC 1 FAULT MEL36-11-01 

-Perform Bite Test of BMC 1 on MCDU (AT A 36)  

AIR BMC 2 FAULT MEL36-11-01 

-Perform Bite Test of BMC 2 on MCDU (ATA 36) 

AIR ENG 1 BLEED FAULT MEL 36-11-01 

-Perform Bite Test of BMC 1 on MCDU (AT A 36)  

AIR ENG 1 BLEED LEAK NO GO 

-Perform Bite Test of BMC 1 on MCDU (ATA 36) 

AIR ENG 1 BLEED NOT CLSD MEL 36-11-02 

-Perform Bite Test of BMC 1 on MCDU (ATA 36) 

AIR ENG 1 HPV NOT OPEN MEL 36-11-07 

-Perform Bite Test of BMC 1 on MCDU (ATA 36) 

AIR ENG 2 BLEED FAULT MEL 36-11-01 

-Perform Bite Test of BMC 2 on MCDU (ATA 36) 

AIR ENG 2 BLEED LEAK NO GO 

-Perform Bite Test of BMC 2 on MCDU (ATA 36) 

AIR ENG 2 BLEED NOT CLSD MEL 36-11-02 

-Perform Bite Test of BMC 2 on MCDU (ATA 36) 

AIR ENG 2 HPV NOT OPEN MEL 36-11-07

-Perform Bite Test of BMC 2 on MCDU (ATA 36) 

AIR HOT AIR SYS 1 FAULT MEL 21-63-03

-Reset breaker ZONE CONT on RH reset panel 

5

Page 6: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 6/28

 

ECAM WARNING A330AIR HOT AIR SYS 2 FAULT MEL 21-63-03 

-Reset breaker ZONE CONT on RH reset panel 

AIR L WING LEAK NO GO 

-Perform test of BMC 1 and 2 on MCDU (AT A 36)  -Switch ON/OFF Engine 1 bleed 

AIR L WING LEAK DET FAULT NO GO 

-Perform test of BMC 1 and 2 on MCDU (AT A 36)  

AIR PACK 1 + 2 FAULT NO GO

- Check push button packs 1 and 2 ON 

-Passenger doors not closed and locked? 

AIR PACK 1 OFF MEL 21-52-01

- Check push button packs 1 ON 

AIR PACK 1 OVHT MEL 21-52-01

-Perform System Test of the Temp Ctrl system on MCDU (ATA 21 )  -Faulty Pack Controller 1 (531HH) 

AIR PACK 1 REGUL FAULT

AIR PACK 1 RAM DOOR CLOSED

MEL 21-52 or MEL 21-53

or MEL 21-53.04 

-Perform System Test of the Temp Ctrl system on MCDU (ATA 21) -Faulty Pack Controller 1 (531 HH) 

AIR PACK 2 OFF MEL 21-52-01

- Check push button packs 2 ON 

AIR PACK VALVE 1 FAULT MEL 21-51-01 or MEL 21-

52-01

-Faulty Pack Controller 1 (531 HH) 

AIR PACK VALVE 2 FAULT MEL 21-51-01 or MEL 21-52-01

-Faulty Pack Controller 2 (532 HH) 

AIR PACK 2 OVHT MEL 21-52-01

- Perform System Test of the Temp Ctrl system on MCDU (ATA 21)  - Faulty Pack Controller 2 (532HH) 

AIR PACK 2 REGUL FAULTAIR PACK 2 RAM DOOR CLOSED

MEL 21-52 or MEL 21-53or MEL 21-53-04

- Perform System Test of the Temp Ctrl system on MCDU (ATA 21)  - Faulty Pack Controller 2 (532HH) 

AIR R WING LEAK NO GO 

- Perform Bite Test of BMC 1 and 2 on MCDU (ATA 36)  - Switch ON/OFF Engine 2 bleed 

AIR R WING LEAK DET FAULT NO GO 

- Perform Bite Test of BMC 1 and 2 on MCDU (ATA 36)  

AIR X BLEED FAULT MEL 36-12-04 

- Perform Bite Test of BMC 1 and 2 on MCDU (ATA 36)  

AUTO FLT A330

AUTO FL T A/THR LIMITED Not applicable 

- Operational message. No further action required. 

AUTO FL T A/THR OFF MEL 22-30-01 

- Reset breaker FMGEC1 on LH reset panel - Reset breaker FMGEC2 on RH reset panel 

AUTO FL T AP OFF MEL 22-10-01 - Reset breaker FMGEC1 on LH reset panel - Reset breaker FMGEC2 on RH reset panel - Recycle FCPC1, 2 and 3 (Flight Control Primary Computer) 

6

Page 7: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 7/28

 

ECAM WARNING A330AUTO FLT FCU FAULT NO GO 

. Reset breaker FMGEC1 on LH reset panel - Reset breaker FMGEC2 on RH reset panel . Reset breaker FCU1 on LH reset panel - Reset breaker FCU2 on RH reset panel 

AUTO FLT FM 1 + 2 FAULT MEL 22-83-01 

- Reset breaker FMGEC1 on LH reset panel - Reset breaker FMGEC2 on RH reset panel 

AUTO FLT FM 1 FAULT MEL 22-72-01 

- Reset breaker FMGEC1 on LH reset panel 

AUTO FLT FM 2 FAULT MEL 22-72-01 

- Reset breaker FMGEC2 on RH reset panel 

AUTO FL T REAC W/S DET FAULT MEL 22-60-02-B 

- Perform System test of Auto Flight System on MCDU (ATA 22) 

COM A330

COM ACARS 1 FAULT MEL 23-24-01 

- Perform Bite test of ACARS on MCDU (COM-Radio) 

COM ACARS ALERT Not applicable 

-If no message on PFR…NO ACTION 

COM ACARS CALL Not applicable 

- If no message on PFR…NO ACTION 

COM CIDS 1 + 2 FAULT MEL 23-73-01 

-Reset breakers CIDS1, CIDS2 and DMC3 on reset panels RH and LH  

COM CIDS PA FAULT MEL 23-31-01

-Perform Interface and Power Up test as follow: -Open CB’s CIDS DIR2 and DIR1 ESS on panel 742VU 

-Open CB’s CIDS DIR2 and DIR1 NORM on panel 722VU 

-Close all breakers again 

COM HF 1 EMMITTING NO GO 

- Reset breaker 2RE1 on panel 721VU 

COM HF 2 EMMITTING NO GO 

- Reset breaker 2RE2 on panel 722VU 

COM VHF 1 EMMITTING NO GO 

- Reset breaker 2RC1 on breaker panel 742VU 

COM VHF 2 EMMITTING NO GO 

- Reset breaker 2RC2 on breaker panel 722VU COM_VFH3 EMMMITTING NO GO 

-Reset breaker 2RC3 on breaker oanel721VU 

ELEC A330

ELEC AC BUS 1 FAULT NO GO 

-Perform Bite test of the ECMU1 on MCDU (AC page)  

ELEC AC BUS 2 FAULT NO GO 

- Perform Bite test of the ECMU2 on MCDU (AC page)  

7

Page 8: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 8/28

 

ECAM WARNING A330ELEC AC ESS BUS AL TN NO GO 

-Perform operational test of the ESS Generation Manual switching 1- Open CB 1XC on panel 715VU 

2- Release AC ESS FEED pushbutton 3- Close CB 1XC on panel 715VU 

4- Push the AC ESS FEED pushbutton 

-Perform operational test of the ESS Generation Automatic switching 1- Open CB 41XN and 5XC on panel 721VU 

2- Close CB 41XN and 5XC on oanel721VU 

ELEC AC ESS BUS FAULT NO GO 

-Open and close CB 17XH on panel 742VU 

-Open and close CB 12XH on panel 7 42VU 

ELEC AC ESS BUS SHED NO GO 

-Open and close CB 8XH on panel 742VU 

-Open and close CB 15XH on panel 742VU 

-Open and close CB 17XH on panel 742VU 

ELEC APU BAT FAULT MEL 24-38-01-A 

-Switch APU battery ON/OFF ELEC APU BAT OFF MEL 24-38-01-A 

-Operational message. No further action required. 

ELEC APU BCL FAULT MEL 24-38-01-B 

-Switch APU battery ON/OFF 

ELEC APU GEN FAULT MEL 24-23-01 

-Perform APU GCU Bite Test on MCDU (ATA 24-AC-EPGS) 

ELEC APU GEN OVERLOAD MEL 24-26-01 

-Perform EMCU Bite Test on MCDU (AT A 24-AC-EMCU) 

ELEC APU TR FAULT MEL 24-32-01 

-Perform APU TR reset on APU TR or with MCDU 

(ATA 24 –TEST ELEC/DC –TR –APU TR –APU TR RESET) ELEC BAT 1 FAULT MEL 24-38-01-A 

-Switch OFF/ON the BAT 1 switch 

ELEC BAT 1 OFF Not applicable 

-Switch ON the BAT 1 switch 

ELEC BAT 2 FAULT MEL 24-38-01-A 

-Switch OFF/ON the BAT 1 switch 

ELEC BAT 2 OFF Not applicable 

-Switch ON the BAT 2 switch 

ELEC BCL 1 FAULT MEL 24-38-01-B 

-Recycle BAT 1 switch 

ELEC BCL 2 FAULT MEL 24-38-01-B 

-Recycle BAT 2 switch 

ELEC BUS TIE OFF Not applicable 

-Switch the BUS TIE ON 

ELEC C/B MONITOR FAULT MEL 24-53-01-A 

-Performed CBMU Bite Test on MCDU (ATA24-AC-CBMU) 

ELEC C/B TRIPPED Refer to affected system 

-Operation message. No further action required

ELEC DC BAT BUS FAULT NO GO 

- Reset breakers ECMU 1 & 2 at panels 722VU and 742VU  

ELEC DC BUS 1 + 2 FAULT NO GO 

- Check GPCU 

ELEC DC BUS 1 FAULT NO GO 

- Reset breakers ECMU 1 & 2 at panels 722VU and 742VU  

8

Page 9: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 9/28

 

ECAM WARNING A330ELEC DC BUS 2 FAULT NO GO 

- Reset breakers ECMU 1 & 2 at panels 722VU and 742VU  

ELEC DC ESS BUS FAULT NO GO 

- Check ELEC/DC system for normal configuration 

ELECDC ESS BUS SHED NO GO 

- Reset breaker 801PP and 805PP at panel 742VU position N63  

ELEC ECMU 1 FAUL T MEL 24-29-01

- Perform ECMU 1 Bite test on MCDU (AT A 24-AC-ECMU 1 )  

ELEC ECMU 2 FAULT MEL 24-29-01 

- Perform ECMU 2 Bite test on MCDU (ATA 24-AC-ECMU2) 

ELEC EMER CONFIG NO GO 

- Operational message. No further action required. 

ELEC ESS TR FAULT MEL 24-34-01 

- Perform ESS TR reset on ESS TR or MCDU 

- (ATA 24 – TEST ELEC/DC – TR – ESS TR – ESS TR RESET)  

ELEC EXT PWR A OVERLOAD MEL 24-26-01 

- Perform ECMU 2 Bite Test on MCDU (ATA 24-AC-ECMU) 

ELEC EXT PWR B OVERLOAD MEL 24-26-01 - Perform ECMU 1 Bite Test on MCDU (ATA 24-AC-ECMU) 

ELEC GEN 1 FAULT MEL 24-22-01 

- Perform GCU Bite Test on MCDU (AT A 24-AC-EPGS-GCU/GPCU) 

ELEC GEN 1 OFF Not applicable 

- Recycle Pus-button switch ELEC/GEN 1 

ELEC GEN 1 OVERLOAD MEL 24-26-01 

- Push galley and commercial P/BSW OFF and check RCCB’s 

ELEC GEN2FAULT MEL 24-22-01 

- Perform GCU Bite Test on MCDU (ATA 24-AC-EPGS-GCU/GPCU) 

ELEC GEN 2 OFF Not applicable 

- Recycle Pus-button switch ELEC/GEN 2 ELEC GEN 2 OVERLOAD MEL 24-26-01 

- Push galley and commercial P/BSW OFF and check RCCB’s 

ELEC IDG 1 DISCONNECTED MEL 24-22-01 

- Check Post Flight Report for IDG OIL OVHT or La OIL Pressure - Check oil level - Reconnect 

ELEC IDG 1 MINOR FAULT MEL 24-22-02 

. Check Post Flight Report for high or low oil level - Check IDG 1 cooler, clogged filter or T oil temp. 

ELEC IDG1 OIL LO PR MEL 24-22-01 

- Check IDG 1 oil level or IDG 1 cooler ELEC IDG 1 OIL OVHT MEL 24-22-01 

- Check IDG 1 oil level or IDG 1 cooler 

ELEC IDG 2 DISCONNECTED MEL 24-22-01 

- Check Post Flight Report for IDG OIL OVHT or La OIL Pressure - Check oil level - Reconnect 

ELEC IDG 2 MINOR FAULT MEL 24-22-02 

Check Post Flight Report for high or low oil level . Check IDG 2 cooler, clogged filter or T oil temp. 

ELEC IDG2 OIL LO PR MEL 24-22-01 

- Check IDG 2 oil level or IDG 2 cooler 

ELEC IDG 2 OIL OVHT MEL 24-22-01 

. Check IDG 2 oil level or IDG 2 cooler 

9

Page 10: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 10/28

 

ECAM WARNING A330ELEC STATIC INV FAULT NO GO 

- Check breaker 6XB “STAT INV CTL” on panel 742VU position N65  

ELEC TR 1 FAULT MEL 24-32-01 

- Perform TR 1 reset on TR 1 or with MCDU  

- (AT A 24 – TEST ELEC/DC – TR – TR1 – TR1 RESET)  

ELEC TR 2 FAULT MEL 24-32-01 

- Perform TR 2 reset on TR 2 or with MCDU  

- (AT A 24 – TEST ELEC/DC – TR – TR2 – TR2 RESET)  

APU FIRE A330 APU FIRE NO GO 

- Perform Bite Test of the APU Fire and Overheat Detection Unit 

ATA 26 – Fire Prot: ENG/APU – FDU APU – Test 

SMOKE A330SMOKE AFT CRG BTL 1 FAULT MEL 26-23-01

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  

SMOKE AFT CRG BTL 2 FAULT MEL 26-23-01 

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  

SMOKE AFT CRG DET FAULT MEL 26-16-02 

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  

SMOKE AFT/BULK CRG SMOKE NO GO 

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  - If no real smoke in bulk.. .or oil in the Air cond system, Perform Bite Test of Smoke Detection System with MCDU 

(AT A 26-SMOKE- TEST) 

SMOKE AVIONICS DET FAULT- NO GO 

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  SMOKE AVNCS VENT SMOKE NO GO 

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  - If no real smoke in avionics…or oil in the Air cond system, Perform Bite Test of Smoke Detection System with MCDU 

(AT A 26-SMOKE- TEST) 

SMOKE BULK CRG DET FAULT MEL 26-16-03 

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  

SMOKE CAB REST DET FAULT MEL 26-18-02 

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  

SMOKE DETFAULT NO GO 

- Reset breakers CIDS 1 and 2 on LH and RH reset panels  - Reset breakers SDCU 1 and 2 on LH and RH reset panels  

SMOKE FLT REST DET FAULT MEL 26-18-01 

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  

SMOKE FWD CRG BTL 1 FAULT MEL 26-23-01 

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  

SMOKE FWD CRG BTL 2 FAULT MEL 26-23-01 

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  

SMOKE FWD CRG DET FAULT MEL 26-16-01 

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  

10

Page 11: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 11/28

 

ECAM WARNING A330SMOKE FWD CRG SMOKE NO GO 

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  - If no real smoke in fwd cargo…or oil in the Air cond system, Perform Bite Test of Smoke Detection System with MCDU 

(AT A 26-SMOKE- TEST) 

SMOKE LAVATORY DET FAULT MEL 26-17-01 

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  

SMOKE LAVATORY SMOKE

- Reset breakers SDCU 1 and 2 on LH and RH reset panels  - If no real smoke in toilet…or oil in the Air cond system, 

Perform Bite Test of Smoke Detection System with MCDU 

(AT A 26-SMOKE- TEST) 

F/CTL A330

F/CTL ADR DISAGREE NO GO 

- Check Post Flight Report 

F/CTL AIL SERVO FAULT MEL 27-14-01

-Recycle FCPC 2 (Flight Control Primary Computer) 

F/CTL ALTN LAW NO GO 

-Recycle FCPC 1 & 2 (Flight Control Primary Computer) -Recycle FCSC 1 & 2 (Flight Control Secondary Computer) 

F/CTL ECVT LAW NO GO

-Check Post Flight Report 

F/CTL ELEV REDUND LOST NO GO 

-Perform Bite Test of the EFCS ground scanning with MCDU 

(AT A 27 –F/CTL –EFCS –EFCS1 –GND SCANNING) 

F/CTL ELEV SERVO FAULT MEL 27-34-01 

-Perform Bite Test of the EFCS ground scanning with MCDU 

(AT A 27 –F/CTL –EFCS –EFCS1 –GND SCANNING) 

F/CTL FCFC 1 FAULT MEL 27-95-01 

-Reset breaker FCDC 1 on LH reset panel 

F/CTL FCDC 1+2 FAULT MEL 27-95-01 

-Reset breaker FCDC 1 and 2 on LH & RH reset panels  

F/CTL FCDC 2 FAULT MEL 27-95-01 

-Reset breaker FCDC 2 on RH reset panel 

F/CTL FLAP SYS 1 FAULT MEL 27-51-01 

-Recycle breakers SFCC 1 NORM on 721VU pas X14 

-Recycle breakers SFCC 1 AVAIL on 721VU pas X13 -Recycle breakers SFCC 1 SLAT on 742VU pas L62 -Recycle breakers SFCC 1 FLAP on 742VU pas L61 

F/CTL FLAPSYS2FAULT MEL 27-51-01 

-Recycle breakers SFCC 2 SLAT on 722VU pas T43 -Recycle breakers SFCC 2 FLAP on 722VU pas V40 

F/CTL FLAP TIP BRK FAULT NO GO 

- Reset Wing Tip Brake with MCDU 

(AT A 27 –FLAP/SLAT –SFCC 1 (2) –FLAP –PCU/WTB TEST/RESET) SFCC/WTB RESET –CONFIRM OF SFCC/WTB RESET) 

F/CTL FLAP/MCDU DISAGREE NO GO 

-Check Post Flight Report 

11

Page 12: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 12/28

 

ECAM WARNING A330F/CTL FLAPS FAULT NO GO 

-Reset Wing Tip Brake with MCDU 

(AT A 27 -FLAP/SLAT -SFCC 1(2) -FLAP -PCU/WTB TEST/RESET SFCC/WTB RESET -CONFIRM OF SFCC/WTB RESET) 

F/CTL FLAPS LOCKED NO GO 

-Reset Wing Tip Brake with MCDU 

(AT A 27 -FLAP/SLAT -SFCC 1 (2) -FLAP -PCU/WTB TEST/RESET SFCC/WTB RESET -CONFIRM OF SFCC/WTB RESET) 

F/CTL GND SPLR FAULT MEL 27-92-02 orMEL 32-42-05 

-Recycle Flight Control Primary Computer (FCPC) 1, 2 and 3 

F/CTL IR DISAGREE NO GO 

-Check Post Flight Report 

F/CTL L ELEV FAULT NO GO 

-Perform Bite Test of the EFCS ground scanning with MCDU 

(ATA 27 -F/CTL -EFCS -EFCS1 -GND SCANNING) 

F/CTL L INR AIL FAULT NO GO 

-Perform Bite Test of the EFCS ground scanning with MCDU (ATA 27 -F/CTL -EFCS -EFCS1 -GND SCANNING) 

F/CTL OUTRAIL FAULT H NO GO 

-Perform Bite Test of the EFCS ground scanning with MCDU 

(ATA 27 -F/CTL -EFCS -EFCS1 -GND SCANNING) 

F/CTL L SIDESTICK FAULT NO GO 

-Check Post Flight Report 

F/CTL L+R ELEV FAULT NO GO 

-Perform Bite Test of the EFCS ground scanning with MCDU 

(ATA 27 -F/CTL -EFCS -EFCS1 -GND SCANNING) 

F/CTL PRIM 1 FAULT MEL 27-93-01

-Recycle FCPC 1 (Flight Control Primary Computer)

F/CTL PRIM 1 PITCH FAULT MEL 27-44-01 or MEL 27-93-01 

- Recycle FCPC 1 (Flight Control Primary Computer) 

F/CTL PRIM 2 FAULT MEL 27-93-01 

-Recycle FCPC 2 (Flight Control Primary Computer) 

F/CTL PRIM 2 PITCH FAULT MEL 27-44-01 or MEL 27-

93-01 

-Recycle FCPC 2 (Flight Control Primary Computer) 

F/CTL PRIM 3 FAULT MEL 27-93-01 

- Recycle FCPC 3(Flight Control Primary Computer) 

F/CTL PRIM 3 PITCH FAULT MEL 27-44-01 or ME 27-93-01 

-Recycle FCPC 3 (Flight Control Primary Computer) 

F/CTL R ELEV FAULT NO GO

-Perform Bite Test of the EFCS ground scanning with MCDU 

(AT A 27 –F/CTL –EFCS –EFCS1 –GND SCANNING) 

F/CTL R INR AIL FAULT NO GO 

-Perform Bite Test of the EFCS ground scanning with MCDU 

(AT A 27 –F/CTL –EFCS –EFCS1 –GND SCANNING) 

F/CTL ROUTR AIL FAULT NO GO 

-Perform Bite Test of the EFCS ground scanning with MCDU 

(AT A 27 –F/CTL –EFCS –EFCS1 –GND SCANNING) F/CTL R SIDESTICK FAULT NO GO 

-Check Post Flight Report 

12

Page 13: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 13/28

 

ECAM WARNING A330F/CTL RUD B SERVO JAM MEL 27-25-02-A

-Perform the operational test of the Rudder Servo Control Pressurize the Blue Hydraulic System with the electrical pumpRelease the LEAK MEASUREMENT VALVES/G pus-button.Release the LEAK MEASUREMENT VALVES/y pus-buttonSlowly push the right pedal until it touches the mech. Stop.

Slowly push the left pedal until it touches the mech. Stop.Put the pedals in the neutral position

If rudder moves during test…Replace jamming detection switchIf rudder does not move during TestsReplace rudder servo-control 

F/CTL RUD G SERVO JAM MEL 27-25-02-A 

-Perform the operational test of the Rudder Servo Control Pressurize the green Hydraulic System with the electrical pumpRelease the LEAK MEASUREMENT VALVES/B pus-buttonRelease the LEAK MEASUREMENT VALVES/y pus-button

Slowly push the right pedal until it touches the mech. StopSlowly push the left pedal until it touches the mech. Stop

Put the pedals in the neutral positionIf rudder moves during test…Replace jamming detection switchIf rudder does not move during Tests …replace rudder servo-control 

F/CTL RUD TRIM 1 FAULT MEL 27-22-01 

-Recycle Flight Control Primary Computer (FCPC) 1, 2 and 3 

F/CTL RUD TRIM 2 FAULT MEL 27-22-01

-Recycle Flight Control Primary Computer (FCPC) 1, 2 and 3 

F/CTL RUD TRIM FAUL MEL 27-22-01

-Push rudder trim reset switch on the rudder trim control panel (115VU)  

F/CTL RUD TRV LIM 1 FAULT MEL 27-23-01 

-Recycle Flight Control Primary Computer (FCPC) 1, 2 and 3 

F/CTL RUD TRV LIM 2 FAULT MEL 27-23-01 

-Recycle Flight Control Primary Computer (FCPC) 1, 2 and 3 

F/CTL RUD TRV LIM FAULT MEL 27-23-01 

-Perform Bite Test of the EFCS ground scanning with MCDU 

(AT A 27 –F/CTL –EFCS –EFCS1 –GND SCANNING) 

F/CTL RUD Y SERVO JAM MEL 27-25-02-A 

-Perform the operational test of the Rudder Servo Control 

Pressurize the yellow Hydraulic System with the electrical pumpRelease the LEAK MEASUREMENT VALVES/B pus-buttonRelease the LEAK MEASUREMENT VALVES/G pus-buttonSlowly push the right pedal until it touches the mech. StopSlowly push the left pedal until it touches the mech. StopPut the pedals in the neutral position

If rudder moves during test…Replace jamming detection switchIf rudder does not move during Tests…replace rudder servo-control 

F/CTL SEC 1 FAULT MEL 27-94-01 

-Recycle Flight Control Secondary Computer (FCSC) 1 and 2 

F/CTL SEC 1 PITCH FAULT MEL 27-94-01 

-Recycle Flight Control Secondary Computer (FCSC) 1 and 2 

F/CTL SEC 2 FAULT MEL 27-94-01 

-Recycle Flight Control Secondary Computer (FCSC) 1 and 2 

F/CTL SEC 2 PITCH FAULT MEL 27-94-01 

-Recycle Flight Control Secondary Computer (FCSC) 1 and 2 

F/CTL SENSOR FAULT MEL 27-92-05 orMEL 27-92-06

-Recycle Flight Control Primary Computer (FCPC) 1 and 3 

13

Page 14: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 14/28

 

ECAM WARNING A330F/CTL SLAT SYS 1 FAULT MEL 27-81-01 

-Recycle breakers SFCC 1 NORM on 721VU pas X14-Recycle breakers SFCC 1 AVAIL on 721VU pas X13-Recycle breakers SFCC 1 SLAT on 742VU pas L62-Recycle breakers SFCC 1 FLAP on 742VU pas L61 

F/CTL SLAT SYS 2 FAULT MEL 27-81-01 

-Recycle breakers SSFCC 2 SLAT on 722VU pas T 43 -Recycle breakers SFCC 2 FLAP on 722VU pas V40 

F/CTL SLAT TIP BRK FAULT NO GO

-Reset Wing Tip Brake with MCDU 

(ATA 27 -FLAP/SLAT -SFCC 1(2) -FLAP -PCU/WTB TEST/RESET SFCC/WTB RESET -CONFIRM OF SFCC/WTB RESET) 

F/CTL SLATS FAULT NO GO

-Reset Wing Tip Brake with MCDU 

(ATA 27 -FLAP/SLAT -SFCC 1(2) -FLAP -PCU/WTB TEST/RESET SFCC/WTB RESET -CONFIRM OF SFCC/WTB RESET) 

F/CTL SLATS LOCKED NO GO-Reset Wing Tip Brake with MCDU 

(AT A 27 -FLAP/SLAT -SFCC 1(2) -FLAP -PCU/WTB TEST/RESET SFCC/WTB RESET -CONFIRM OF SFCC/WTB RESET) 

F/CTL SPD BRK DISAGREE MEL 27-92-01 

-Check Post Flight Report 

F/CTL SPD BRK FAULT MEL 27-92-01 

-Perform Bite Test of the EFCS ground scanning with MCDU 

(ATA 27 -F/CTL -EFCS -EFCS1 -GND SCANNING) 

F/CTL SPLR FAULT MEL 27-64-01 

-Recycle Flight Control Primary Computer (FCPC) 1 and 3 

F/CTL STAB CTL FAULT NO GO 

-Perform Test of the EFCS ground scanning with MCDU 

F/CTL TURB DAMP FAULT MEL 27-93-05 

-Recycle Flight Control Primary Computer (FCPC) 1 and 3 

F/CTL YAW DAMPER 1 MEL 27-26-01 

-Recycle Flight Control Primary Computer (FCPC) 1-Recycle Flight Control Secondary Computer (FCSC) 1 

F/CTL YAW DAMPER 2 MEL 27-26-01 

-Recycle Flight Control Primary Computer (FCPC) 3 -Recycle Flight Control Secondary Computer (FCSC) 2 

F/CTL YAW DAMPER FAULT MEL 27-26-01

-Perform Bite Test of the EFCS ground scanning with MCDU 

(ATA 27 –F/CTL –EFCS –EFCS1 –GND SCANNING) 

FUEL A330FUEL ABNORMAL MAN FWD XFR Not applicable 

-No action 

FUEL APU AFT PUMP FAULT MEL 49-30-01-A 

-Reset breakers FCMC 1 and 2 on LH and RH reset panel  

FUEL APU LP VALVE FAULT MEL 49-30-03 

-Reset breakers FCMC 1 and 2 on LH and RH reset panel  

FUEL ENG1 LP VALVE FAULT MEL 28-24-01 -Reset breakers FWC 1 and 2 on LH and RH reset panel  

FUEL ENG2 LP VALVE FAULT MEL 28-24-01

-Reset breakers FWC 1 and 2 on LH and RH reset panel  

14

Page 15: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 15/28

 

ECAM WARNING A330FUEL EXCESS AFT CG (False caution) MEL 28-40-13-A

-Reset breakers FCMC 1 and 2 on LH and RH reset panel  

FUEL FCMC 1 FAULT MEL 28-51-01-A

or MEL 28-51-01-B 

-Reset breakers FCMC 1 on LH reset panel 

FUEL FCMC 1+2 FAULT NO GO 

-Reset breakers FCMC 1 and 2 on LH and RH reset panel  

FUEL FCMC 2 FAULT MEL 28-51-01-Aor MEL 28-51-01-B

-Reset breakers FCMC 2 on RH reset panel 

FUEL FUEL LO TEMP NO GO 

-Reset breakers FCMC1 and 2 on LH and RH reset panel  

FUEL L INNER TK NI TEMP (also DELAY T.O.) Not applicable

-Apply ECAM procedure -If MCDU shows no maintenance message, no further action is required 

FUEL L STBY PUMP LO PR MEL 28-21-01-B-Recycle breaker FUEL L STBY PUMP on 721VU position J05 -Check pump symbol on ECAM/FUEL page 

FUEL L WING PUMPS LO PR MEL 28-21-01-A

and MEL 28-21-01-B 

-Reset breakers FCMC 1 and 2 on LH and RH reset panel  

FUEL L WING TK LO LVL NO GO or MEL

28-46-04-A 

-Check Post Flight Report -Operational message. No further action needed 

FUEL L+R WING TK LO LVL NO GO or MEL

28-46-04-A-Check Post Flight Report -Operational message. No further action needed 

FUEL LEFT PUMP 1 LO PR MEL 28-21-01-A

-Recycle breaker FUEL L PUMP 1 CTL on 722VU position U46 

FUEL LEFT PUMP 2 LO PR MEL 28-21-01-A

-Recycle breaker FUEL L PUMP 2 CTL on 742VU position 068 

FUEL OUTR TO INR FAULT MEL 28-26-01

-Perform the operational test of the FCMS controlled valves 

(ATA 28 –FCMC1 –FUEL VALVES TEST –CONFIRM) 

FUEL R INNER TK HI TEMP (also DELAY T.O.) Not applicable 

-Apply ECAM procedure -If MCOU shows no maintenance message, no further action is required 

FUEL R STBY PUMP LO PR MEL 28-21-01-B

-Recycle breaker FUEL R STBY PUMP on 721VU position J05 

-Check pump symbol on ECAM/FUEL page 

FUEL R WING PUMPS LO PR MEL 28-21-01-Aand MEL 28-21-01-B

-Reset breakers FCMC 1 and 2 on LH and RH reset panel  

FUEL R WING TK LO LVL NO GO orMEL 28-46-04-A 

-Check Post Flight Report 

-Operational message. No further action needed 

FUEL RIGHT PUMP 1 LO PR MEL 28-21-01-A 

-Recycle breaker FUEL R PUMP 1 CTL on 722VU position Q43 

15

Page 16: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 16/28

 

ECAM WARNING A330FUEL RIGHT PUMP 2 LO PR MEL 28-21-01-A 

-Recycle breaker FUEL R PUMP 2 CTL on 721VU position V13 

FUEL T TANK XFR FAULT MEL 28-27 

-Reset breakers FCMC 1 and 2 on LH and RH reset panel  

FUEL TRIM LINE FAULT MEL 28-25-04-Cor 28-27-01 or

28-27-03 or 28-27-04 

-Reset breakers FCMC 1 and 2 on LH and RH reset panel  

FUEL TRIM TK PUMP LO PR MEL 28-27-05 

-Recycle breaker TRIM XFR PUMP CTL on 722VU position Q40 

-Recycle breaker TRIM XFR PUMP SPL Yon 722VU position E40 

FUEL WING TK OVERFLOW NO GO 

-Reset breakers FCMC 1 and 2 on LH and RH reset panel  

FUEL WING X FEED FAULT MEL 28-23-01 

-Recycle Cross Feed Valve P/BSW 

FUEL ZFW ZFCG DISAGREE MEL 28-51-02 

-Check Post Flight Report -Operational message. No further action needed 

HYD A330HYD B + Y SYS LO PR NO GO or MEL

29-30-03-F

-Check Hydraulic levels 

HYD B ELEC PUMP FAULT MEL 29-2-01 orMEL29-30-03-D 

-Recycle breaker HSMU B + PART G on 721VU position U10 

-Recycle breaker HYD PUMP B CTL on 721VU position X12 HYD B ENG 1 PUMP LO PR NO GO 

-Check Blue Hydraulic level -Bleed Blue Hydraulic system 

HYD B RSVR LO AIR PR NO GO or MEL

29-30-03-B 

-Perform the Check of the Air Pressure in the reservoir

-Pressurize the hydraulic reservoir with the APU(With APU running, put the ENG MODE selector switch in CRANK

The APU will boost the air bleed pressure to 4 bars (58 PSI) during 30 sec.Check pressure again after the ENG MODE selector is set back to NORMAL.) 

HYD B RSVR LO LVL NO GO or MEL

29-30-03-A 

- Check Blue Hydraulic level 

HYD B RSVR OVHT NO GO or MEL29-30-03-C 

Check Post Flight Report-HYD G + B SYS LO PR NO DISPATCH or MEL 29-30-03-F-Check Hydraulic levels 

HYD G + Y SYS LO PR NO GO or MEL

29-30-03-F 

-Check Hydraulic levels 

HYD G ELEC PUMP FAULT MEL 29-21-01 or

MEL 29-30-03-D -Recycle breaker HSMU B + PART G on 721VU position U10 

-Recycle breaker HSMU Y + PART G on 722VU position X46 

16

Page 17: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 17/28

 

ECAM WARNING A330HYD G ENG 1 PUMP LO PR NO GO or MEL

29-30-03-E 

-Check Green Hydraulic level -Bleed Green Hydraulic system 

HYD G ENG 1+2 PUMPS LO PR NO GO or MEL29-30-03-E 

-Check Green Hydraulic level HYD G ENG 2 PUMP LO PR NO GO or MEL

29-30-03-E 

-Check Green Hydraulic level -Bleed Green Hydraulic system 

HYD G RSVR LO AIR PR NO GO or MEL

29-30-03-B 

-Perform the Check of the Air Pressure in the reservoir 

-Pressurize the hydraulic reservoir with the APU 

(With APU running, put the ENG MODE selector switch in CRANK 

The APU will boost the air bleed pressure to 4 bars (58 PSI) during 30 sec.  

Check pressure again after the ENG MODE selector is set back to NORMAL.) 

HYD G RSVR LO LVL NO GO or MEL29-30-03-A 

-Check Green Hydraulic level 

HYD G RSVR OVHT NO GO or MEL 29-30-03-C 

-Check Post Flight Report 

HYD G RSVR UNDERFILLED NO GO 

-Check for leaks 

-Refill Green Hydraulic Reservoir 

HYD G SYS LEAK Not applicable 

-Cross check fluid level indication on green reservoir and ECAM hydraulic page 

-Check for external leakage of the hydraulic components HYD MONITORING (with HSMU racked) MEL 29-30-03-H 

-Reset breakers SDAC 1 and 2 on LH and RH reset panels  

HYD RAT FALUT NO GO or MEL29-30-03-G 

-Pressurize the green hydraulic system 

On the yellow hydr. Serv. pnl. set the ON/OFF switch to ON and back OFF 

HYD Y ELEC PUMP FAULT MEL 29-23-01-Aor MEL 29-30-03-D

-Recycle breaker HSMU B + PART G on 721VUpositionU10-Recycle breaker HYD PUMP Y SVCE on 722VU position N46

-Recycle breaker HYD PUMP Y CTL on 722VU position R36-Recycle breaker HSMU Y + PART G on 722VU position X46 

HYD Y RSVR LO AIR PR NO GO or MEL29-30-03-B 

-Perform the Check of the Air Pressure in the reservoir-Pressurize the hydraulic reservoir with the APU

(With APU running, put the ENG MODE selector switch in CRANKThe APU will boost the air bleed pressure to 4 bars (58 PSI) during 30 sec. Check

pressure again after the ENG MODE selector is set back to NORMAL.) 

HYD Y ENG 2 PUMP LO PR NO GO or MEL29-30-03-C 

- Check Yellow Hydraulic level - Bleed Yellow Hydraulic system 

17

Page 18: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 18/28

 

ECAM WARNING A330HYD RSVR LO L VL NO GO or MEL

29-30-03-A 

- Check Hydraulic levels 

HYD Y RSVR OVHT NO GO or MEL29-30-03-C 

- Check Post Flight Report 

A.ICE A330A.ICE CAPT AOA HEAT MEL 30-31-04

- Reset breaker PHC1 on LH reset panel - Perform operational test of the Probe Ice protection with MCDU 

ATA 30 -ICE RAIN:HEATING - PHC 1 - TEST 

A.ICE CAPT PITOT HEAT MEL 30-32-02

- Reset breaker PHC1 on LH reset panel - Perform operational test of the Probe Ice protection with MCDU 

ATA 30 -ICE RAIN:HEATING - PHC 1 - TES 

A.ICE CAPT PROBES HEAT MEL 30-31-01 - Reset breaker PHC1 on LH reset panel - Perform operational test of the Probe Ice protection with MCDU 

ATA 30 - ICE RAIN:HEATING - PHC 1 - TEST 

A.ICE CAPT TAT HEAT MEL 30-31-05 

- Reset breaker PHC1 on LH reset panel - Perform operational test of the Probe Ice protection with MCDU 

ATA 30 -ICE RAIN:HEATING - PHC 1 - TEST 

A.ICE DETECT FAULT MEL-30-81-01 

- Recycle breaker ICE DET 1 on panel 721VU position B08 

- Recycle breaker ICE DET 2 on panel 722VU position F46 

- Perform operational test of the Ice detection system with MCDU ATA 30 -ICE RAIN:DETECTOR - TES 

A.ICE ENG 1 VALVE CLOSED MEL 30-21-01 

- Perform visual inspection of the Anti-Ice supply duct - Check thermal fuse Engine Air Intake Anti Ice Valve - Check Engine Air Intake Anti Ice Valve 5000DN 

A.ICE ENG 1 VALVE OPEM MEL 30-21-01 

- Recycle breaker FADEC B ENG 1 on panel 722VU position D44 

- Recycle breaker FADEC A ENG 1 on panel 742VU position Q73 

A.ICE ENG 2 VALVE CLOSED MEL 30-21-01

- Perform visual inspection of the Anti-Ice supply duct - Check thermal fuse Engine Air Intake Anti Ice Valve 

- Check Engine Air Intake Anti Ice Valve 5000DN 

A.ICE ENG 2 VALYE OPEN MEL 30-21-01 

- Recycle breaker FADEC B ENG 2 on panel 722VU position K49 

- Recycle breaker FADEC A ENG 2 on anel7 42VU position Q74

A.ICE F/O AOA HEAT MEL 30-31-04

- Reset breaker PHC2 on RH reset panel-Perform operational test of the Probe Ice protection with MCDU(ATA 30 –ICE RAIN:HEATING – PHC 2 – TEST)

A.ICE F/O PITOT HEAT MEL 30-31-02

- Reset breaker PHC2 on RH reset panel 

- Perform operational test of the Probe Ice protection with MCDU 

(ATA 30 –ICE RAIN:HEATING - PHC 2 - TES 

A.ICE F/O PROBES HEAT MEL 30-31-01

18

Page 19: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 19/28

 

ECAM WARNING A330- Reset breaker PHC2 on RH reset panel - Perform operational test of the Probe Ice protection with MCDU 

(ATA 30 –ICE RAIN:HEATING - PHC 2 – TEST) 

A.ICE F/O TAT HEAT MEL 30-31-05

- Reset breaker PHC2 on RH reset panel - Perform operational test of the Probe Ice protection with MCDU 

(ATA 30 –ICE RAIN:HEATING - PHC 2 – TEST) A.ICE L + R WINDOW HEAT MEL 30-42-02

- Reset breakers WHC 1 and WHC 2 on LH and RH reset panel

A.ICE L + R WSHLD HEAT MEL 30-42-03

- Reset breakers WHC 1 and WHC 2 on LH and RH reset panel  

A.ICE L CAPT STAT HEAT MEL 30-31-03

- Reset breaker PHC2 on RH reset panel - Perform operational test of the Probe Ice protection with MCDU 

(ATA 30 –ICE RAIN:HEATING - PHC 2 – TEST) 

A.ICE L F/O STAT HEAT MEL 30-31-03 

- Reset breaker PHC2 on RH reset panel - Perform operational test of the Probe Ice protection with MCDU 

(ATA 30 – ICE RAIN: HEATING - PHC 2 – TEST)  

A.ICE L INR WING HI PR NO GO 

-Fault LH inner Wing Anti Ice Valves (10DL1) 

A.ICE L INR WING LP PR MEL 30-11-01 

- Check Wing Anti Ice Control Filter - Fault LH inner Win Anti Ice Valve (10DL1)

A.ICE L INR WING OPEN MEL 30-11-01 

- Fault LH inner Wing Anti Ice Valve (10DL1)

A.ICE L OUTR WING HIGH PR NO GO

- Fault LH outer Win Anti Ice Valve (9DL1)

A.ICE L OUTR WING LO PR MEL 30-11-01

- Faulty LH outer Wing Anti Ice Valve (9DL 1)- Check Wing Anti Ice Control Filter- Fault Bleed Valve (4001HA)

A.ICE L OUTR WING OPEN MEL 30-11-01

- Fault LH outer Win Anti Ice Valve 9DL 1

A.ICE L STBY STAT HEAT MEL 30-31-03

- Reset breaker PHC3 on LH reset panel - Perform operational test of the Probe Ice protection with MCDU 

ATA 30 -ICE RAIN:HEATING - PHC 2 - TES 

A.ICE L WINDOW HEAT MEL 30-42-02

- Reset breaker WHC1 on LH reset panel A.ICE L WSHLD HEAT MEL 30-42-03 

- Reset breaker WHC1 on LH reset panel 

A.ICE R CAPT STAT HEAT MEL 30-31-03 

- Reset breaker PHC1 on LH reset panel 

R F/O STAT HEAT MEL 30-31-03 

- Reset breaker PHC2 on RH reset panel 

A.ICE R INR WING HI R NO GO 

Fault RH inner Win Anti Ice Valve 10DL2 

A.ICE R INR WING LO PR MEL 30-11-01 

- Faulty RH inner Wing Anti Ice Valve (10DL2) 

- Check Win Anti Ice Control Filter A.ICE R INR WING OPEN MEL 30-11-01 

- Fault RH inner Win Anti Ice Valve 1 ODL2 

A.ICE R OUTR WING HI PR NO GO 

19

Page 20: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 20/28

 

ECAM WARNING A330- Fault RH outer Win Anti Ice Valve 9DL2 

A.ICE R OUTR WING LO PR MEL 30-11-01 

- Faulty RH outer Wing Anti Ice Valve (9DL2) - Check Win Anti Ice Control Filter 

A.ICEE R OUTR WING OPEN MEL 30-11-01 

- Fault RH outer Win Anti Ice Valve 9DL2 

A.ICE R STBY STAT HEAT MEL 30-31-03 

- Reset breaker PHC3 on LH reset panel 

A.ICE R WINDOW HEAT MEL 30-42-02

- Reset breaker WHC2 on RH reset panel 

A.ICE R WSHLD HEAT MEL 30-42-03 

- Reset breaker WHC2 on RH reset panel 

A.ICE STBY AOA HEAT MEL 30-31-04

- Reset breaker PHC3 on LH reset panel 

A.ICE STBY PITOT HEAT MEL 30-31-02 

- Reset breaker PHC3 on LH reset panel 

A.ICE STBY PROBES HEAT MEL 30-31-01 

- Reset breaker PHC3 on LH reset panel A.ICE WAI SYS FAULT MEL 30-11-01

- Faulty Wing Anti Ice Control Relay (5DL) - Faulty Wing Anti Ice Relay (11 DL) - Fault Push Button Switch 3DL 

A.ICE WING OPEN ON GND MEL 30-11-01 

- Faulty Wing Anti Ice System Mode Relay (6DL) - Fault Win Anti Ice Ground Relay (4DL)

A.ICE WING VLV NOT GND MEL 30-11-01

- Faulty RH outer Wing Anti Ice Valve (9DL2) - Faulty LH outer Wing Anti Ice Valve (9DL1) 

- Faulty RH inner Wing Anti Ice Valve (10DL2) - Faulty LH inner Wino Anti Ice Valve (10DL1) 

EIS A330

EIS DISPLY DISCREPANCY NO GO 

-Reset breaker DMC 1,2 and 2 on LH and RH reset panel 

EIS ECAM DMC 1 FAULT MEL 31-62-01-B 

-Reset breaker DMC 1 on LH reset panel 

EIS ECAM DMC 2 FAULT ME 31-62-01-B MEL 31-62-01-B -Reset BREAKER DMC2 on RH reset panel

EIS ECAM DMC 3 FAULT MEL 31-62-01-B 

-Reset breaker DMC3 on LH reset panel 

EIS EFIS DMC 1 FAULT MEL 31-62-01-A 

-Reset breaker DMC1 on LH reset panel 

EIS EFIS DMC 2 FAULT MEL 31-62-01-A 

-Reset breaker DMC 2 on RH reset panel 

EIS EFIS DMC 3 FAULT MEL 31-62-01-A 

-Reset breaker DMC 3 on LH reset panel 

FWS A330

FWS EPC FAULT MEL 31-56-01

20

Page 21: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 21/28

 

ECAM WARNING A330- Reset breaker FWC 1 and SDAC 1 on LH reset panel  - Reset breaker FWC 2 and SDAC 2 on RH reset panel  

FWS FWC1 FAULT MEL 31-53-01 

- Reset breaker FWC 1 on LH reset panel 

FWS FWC 1+2 FAULT MEL 31-53-01 

- Reset breaker FWC 1 and 2 on LH and RH reset panel  

FWS 2 FAULT MEL 31-53-01 

- Reset breaker FWC 2 on RH reset panel 

FWS SDAC 1 FAULT MEL 31-55-01 

- Reset breaker SDAC 1 on LH reset panel 

FWS SDAC 1+2 FAULT MEL 31-55-01 

- Reset breaker SDAC 1 and SDAC 2 on LH and RH reset panel  

FWS SDAC 2 FAULT MEL 31-55-01 

- Reset breaker SDAC 2 on RH reset panel 

RECORDER A330

RECORDER DFDRFAULT

- Recycle breaker FDIU/DFDR on panel 722VU position F42 

RECORDER FDIU FAULT

- Recycle breaker FDIU/DFDR on panel 722VU position F42 

BRAKES A330

BRAKES A/SKID NWS OFF Not applicable - No action necessary (Switch A/SKID & N/W STRG is set to OFF) 

BRAKES ANTI SKID FAULT NO GO 

- Recycle A/SKID & N/W STRG switch on F/O instrument panel 

BRAKES AUTO BRAKE FAULT MEL 32-42-02 or32-42-04 

- Recycle A/SKID & N/W STRG switch on F/O instrument panel 

BRAKES BSCU CH 1 FAULT MEL 32-42-03 

- Perform Bite test of BSCU 1 on MCDU (AT A 32 - Breaking/Steering - BSCU CH 1)  

BRAKES BSCU CH 2 FAUL T-

- Perform Bite test of BSCU 2 on MCDU (AT A 32 - Breaking/Steering - BSCU CH2)  

BRAKES HOT NO GO 

- Cool down brakes with Brake Fan 

BRAKES RELEASED MEL 32-42-01 or

32-42-05 

- Perform Bite test of BSCU 1 on MCDU (ATA 32 - Breaking/Steering - BSCU CH1)  

- Perform Bite test of BSCU 2 on MCDU (ATA 32 - Breaking/Steering - BSCU CH2)  

BRAKES RESIDUAL BRAKING MEL 32-42-01 

- Perform Bite test of BSCU 1 on MCDU (AT A 32 - Breaking/Steering - BSCU CH 1 )  - Perform Bite test of BSCU 2 on MCDU (AT A 32 - Breaking/Steering - BSCU CH2)  

21

Page 22: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 22/28

 

ECAM WARNING A330

L/G A330

L/G DOORS NOT CLOSED NO GO 

-Perform visual check of landing gear doors -Reset breaker LGCIU 1 and 2 on LH and RH reset panel  

L/G GEAR NOT DOWN Not applicable-No action if no Post Flight Report 

L/G GEAR NOT DOWNLOCKED Not applicable

-Reset breaker LGCIU 1 and 2 on LH and RH reset panel  

L/G GEAR NOT UPLOCKED Not applicable

-Reset breaker LGCIU 1 and 2 on LH and RH reset panel  

L/G GEAR UPLOCK FAULT FCOM 2-04-25 

-Check uplock assembly of all gears 

L/G L LENGTHENING FAULT FCOM 2-04-25 

-Check for damage to the shortening mechanism or the prox. sensor target LH  

L/G R LENGTHENING FAULT FCOM 2-04-25 

-Check for damage to the shortening mechanism or the prox sensor target RH  

L/G LGCIU 1 FAULT MEL 32-31-01 

-Reset breaker FWC 1 and LGCIU 1 on LH reset panel  -Reset breaker FWC 2 and LGCIU 2 on RH reset panel  

L/G LGCIU 1+2 FAULT MEL 32-31-01 

-Reset breaker FWC 1 and LGCIU 1 on LH reset panel  -Reset breaker FWC 2 and LGCIU 2 on RH reset panel  

L/G LGCIU 2 FAULT MEL 32-31-01 

-Reset breaker FWC 1 and LGCIU 1 on LH reset panel  -Reset breaker FWC 2 and LGCIU 2 on RH reset panel  

L/G RETRACTION FAULT FCOM 2-04-25 

-Check for damage to prox sensors targets or attachment brackets L/G SYS DISAGREE NO GO 

-Reset breaker LGCIU 1 and 2 on LH and RH reset panel  -Check for damage to the down lock proximity sensors or targets 

WHEEL A330

WHEEL HYD SEL VALVE NO GO 

- Recycle A/SKID & N/W STRG switch on F/O instrument panel 

WHEEL N/W STRG FAULT MEL 32-51-01 

- Recycle A/SKID & N/W STRG switch on F/O instrument panel - Reset breaker LGCIU 1 and LGCIU 2 on LH and RH reset panel  

WHEEL TIRE LO PR NO GO 

- Recycle A/SKID & N/W STRG switch on FIG instrument panel - Unsatisfactory tire pressure (Adjust tire pressure) 

NAV A330

NAV ADR 1 FAULT MEL 34-10-01-8 

-Reset FWC1 and FWC2 on LH and R panel -Check Post Flight Report 

NAV ADR 1+2 FAULT MEL 34-10-01-8 

-Reset FWC1 and FWC2 on LH and R panel -Check Post Flight Report 

NAV ADR 1+3 FAULT MEL 34-10-01-B

-Reset FWC1 and FWC2 on LH and R panel 

22

Page 23: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 23/28

 

ECAM WARNING A330-Check Post Flight Report 

NAV ADR 2 FAULT MEL 34-10-01-B 

-Reset FWC 1 and FWC2 on LH and RH reset panel  -Check Post Flight Re art 

NAV ADR 2+3 FAULT MEL 34-10-01-B 

-Reset FWC 1 and FWC 2 on LH and RH reset panel  

-Check Post Flight Report 

NAV ADR 3 FAULT MEL 34-10-01-B 

-Reset FWC 1 and FWC 2 on LH and RH reset panel  -Check Post Flight Report 

NAV ALTI DISCREPANCY MEL 34-10-01-8 

- No action is required if there is no Post Flight Report 

NAV ATT DISCREPANCY MEL 34-10-01-A 

-No action is required if there is no Post Flight Report 

NAV EXTREME LATITUDE Not applicable

-No action is required if there is no Post Flight Report 

NAV FM/IR POS DISAGREE Not applicable

-No action is required if there is no Post Flight Report NAV GPWS FAULT MEL 34-38-01 

-Reset FWC 1 and FWC 2 on LH and RH reset panel  

NAV HDG DISCREPANCY MEL 34-10-01-A 

-No action is required if there is no Post Flight Report 

NAV ILS 1 FAULT MEL 34-36-01

-Reset FWC 1 and FWC 2 on LH and RH reset panel  

NAV ILS 1+2 FAULT MEL 34-36-01 

-Check the Post Flight Report 

NAV ILS 2 FAULT MEL 34-36-01 

-Reset FWC 1 and FWC 2 on LH and RH reset panel  

NAV IR 1 FAULT MEL 34-10-01-A -Reset FWC 1 and FWC 2 on LH and RH reset panel  

NAV IR 1+2 FAULT MEL 34-10-01-A 

-Check the Post Flight Report 

NAV IR 1+3 FAULT MEL 34-10-01-A 

-Check the Post Flight Report 

NAV IR 2 FAULT MEL 34-10-01-A 

-Reset FWC 1 and FWC 2 on LH and RH reset panel  

NAV IR 2+3 FAULT MEL 34-10-01-A 

-Check the Post Flight Report 

NAV IR 3 FAULT MEL 34-10-01-A 

-Reset FWC 1 and FWC 2 on LH and RH reset panel  NAV IR NOT ALIGNED MEL 34-10-01-A 

-No action is required if there is no Post Flight Report 

NAV RA 1 FAULT MEL 34-42-01 

-Reset FWC 1 and FWC 2 on LH and RH reset panel  

NAV RA 1+2 FAULT MEL 34-42-01 

-If message RA 1 and RA2 is shown only on ground, no action is necessary 

NAV RA 2 FAULT MEL 34-42-01 

-Reset FWC 1 and FWC 2 on LH and RH reset panel  

NAV TCAS FAULT MEL 34-42-01 

-Reset FWC 1 and FWC 2 on LH and RH reset panel  

23

Page 24: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 24/28

 

ECAM WARNING A330

APU A330

APU FAULT MEL 49-11-01 

-Check the Post Flight Report 

APU FIRE DET FAULT MEL 26-13 

-Recycle breaker FDU LOOP 8 APU on panel 721VU position P08 -Recycle breaker FIRE LOOP A APU on panel 742VU position D80 

APU FIRE LOOP A FAULT MEL 26-13-01 

-If Loop A OK …. Faulty FDU (13WG) -Reset FWC 1 and FWC 2 on LH and RH reset panel  

APU FIRE LOOP 8 FAULT MEL 26-13-01 

-If Loop B OK …. Faulty FDU (13WG) -Reset FWC 1 and FWC 2 on LH and RH reset panel  

DOOR A330

DOOR AFT CARGO MEL 52-71-01-B 

- Check proximity sensor and target-Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT) 

DOOR AVIONIC MEL 52-71-01-B 

.Check proximity sensor and target 

-Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT) 

DOOR BULK CARGO MEL 52-71-01-B 

-Check proximity sensor and target 

-Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT) 

DOOR FWD CARGO MEL 52-71-01-B 

-Check proximity sensor and target -Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT) 

DOOR L AFT CABIN MEL 52-71-01-B 

-Check proximity sensor and target -Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT) 

DOOR L EMER EXIT MEL 52-71-01-B 

-Check proximity sensor and target -Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT) 

DOOR L FWD CABIN MEL 52-71-01-B 

-Check proximity sensor and target -Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT) 

DOOR L MID CABIN MEL 52-71-01-B 

-Check proximity sensor and target -Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT) 

DOOR POS DET 1 FAULT MEL 52-71-01-A 

-Reset CPC 1 and CPC 2 on LH and RH reset panels  -Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT) 

DOOR POS DET 1+2 FAULT MEL 52-71-01-A 

-Reset CPC 1 and CPC 2 on LH and RH reset panels  -Recycle breaker DOORS & SLIDES CTL on panel 721VU position N09 -Recycle breaker DOORS & SLIDES CTL on panel 722VU position P41 

DOOR POS DET 2 FAULT MEL 52-71-01-A 

-Reset CPC 1 and CPC 2 on LH and RH reset panels  -Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT) 

24

Page 25: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 25/28

 

ECAM WARNING A330DOOR R AFT CABIN MEL 52-71-01-B 

-Check proximity sensor and target -Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT) 

DOOR R EMER EXIT MEL 52-71-01-B 

-Check proximity sensor and target -Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT) 

DOOR R FWD CABIN MEL 52-71-01-B 

-Check proximity sensor and target -Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT) 

DOOR R MID CABIN MEL 52-71-01-B 

-Check proximity sensor and target -Perform System test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT) 

CONFIG A330

CONFIG FLAPS NOT IN T.O. RANGE NO GO 

-Check Post Flight Report -Reset FWC 1 and FWC 2 on LH and RH reset panel  

CONFIG L SIDESTICK FAULT Apply ECAMprocedure 

-Check Post Flight Report -If there is no message, no action is necessary 

CONFIG R SIDESTICK FAULT Apply ECAMprocedure 

-Check Post Flight Report -If there is no message, no action is necessary 

CONFIG PARK BRK ON NO GO 

-Set brakes OFF 

CONFIG PITCH TRIM NOT IN T.O. RANGE NO GO 

-Check Post Flight Report -If there is no message, no action is necessary 

CONFIG RUD TRIM NOT IN T.O. RANGE NO GO 

-Check Post Flight Report -If there is no message, no action is necessary 

CONFIG SLATS NOT IN T.O. RANGE NO GO 

-Check Post Flight Report -If there is no message, no action is necessary 

CONFIG SPD BRK NOT RETRACTED NO GO 

-Check Post Flight Report -If there is no message no action is necessary 

ENG A330 ENG THRUST LOSS MEL 73-30-03-B

-Reset breaker ZONE CONT on RH reset panel 

ENG ALL ENG FLAME OUT NO GO 

-Check fuel filters 

ENG THR LRVERS NOT SET MEL 73-20-01

-Operational message, no further action required ENG T.O. THRUST DISAGREE NO GO 

-Check Post Flight Report for defective LRU(s) 

ENG THRUST LOSS MEL 73-30-03-B

25

Page 26: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 26/28

 

ECAM WARNING A330-Reset breaker ZONE CONT on RH reset panel 

ENG1 A330

ENG1 BLEED STATUS Apply ECAM procedure 

-Reset breaker EIVMU 1 on LH reset panel 

ENG1 CTL SYS FAULT NO GO 

-Recycle breaker FADEC A ENG 1 on panel 742VU position Q73 -Recycle breaker FADEC B ENG 1 on panel 722VU position D44 

ENG1 EGT OVERLIMIT Not applicable 

-Perform visual check of engine 

ENG1 EIU FAULT MEL 73-25-02 

-Reset breaker EIVMU 1 on LH reset panel -Reset breaker FCU 1 on LH reset panel 

ENG1 FADEC FAULT NO GO 

-Reset breaker SDAC 1 & 2 on LH and RH reset panel  -Reset breaker FCU 1 on LH reset panel 

ENG1 FADEC OVHT NO GO 

-Check for excessive heat near the EEC (nacelle anti-ice duct) 

ENG1 FADEC SYS FAULT NO GO 

-Reset breaker EIVMU 1 on LH reset panel -Recycle breaker FADEC A ENG 1 on panel 742VU position Q73 -Recycle breaker FADEC B ENG 1 on panel 722VU position D44 

ENG1 FIRE DET FAULT NO GO 

-Perform the bite test of the FDU with MCDU 

(ATA 26 Fire Prot -Engines -FDU -Test) 

ENG1 FIRE LOOP A FAULT MEL 26-12-01 -Perform the bite test of the FDU with MCDU(ATA 26 Fire Prot -Engines -FDU -Test) 

ENG1 FIRE LOOP B FAULT MEL 26-12-01 

-Perform the bite test of the FDU with MCDU 

(AT A 26 Fire Prot -Engines -FDU -Test) 

ENG1 FUEL FILTER CLOG NO GO 

-Check fuel pump filter -Check fuel pump filter differential switch 

ENG1 HP FUEL VALVE NO GO 

-Perform FADEC system static test with MCDU 

(AT A 70-80 Engine -EEC 1 -System test) ENG1 IGN A FAULT MEL 74-31-01 or

74-31-03-A 

-Reset breaker EIVMU 1 on LH reset panel 

ENG1 IGN B FAULT MEL 74-31-01 or74-31-03-A 

-Reset breaker EIVMU 1 on LH reset panel 

ENG1 IGN A+B FAULT MEL 74-31-01 or

74-31-03-A 

-Reset breaker FWC 1 & 2 on LH and RH reset panel  

ENG1 MINOR FAULT MEL 73-25-01-A 

-Recycle breaker FADEC A ENG 1 on panel 742VU position Q73

-Recycle breaker FADEC B ENG 1 on panel 722VU position D44 

26

Page 27: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 27/28

 

ECAM WARNING A330ENG1 OIL FILTER CLOG NO GO or

MEL 79-35-02-A 

-Check oil filter -Check oil filter differential switch 

ENG1 OIL HI TEMP NO GO 

-Check engine oil level 

ENG1 OIL LO TEMP Apply ECAM procedure- Operational message - No further action required 

ENG1 OIL LO PRESS NO GO orMEL 79-34-01-A 

- Check engine oil level and check for leaks

ENG1 REV FAULT MEL 78-30-01

- Reset breaker EIVMU 1 on LH reset panel 

ENG1 REV PRESSURIZED NOT GO

Heat the TRDV (directional pilot valve) using hot air source to de-ice the press switch if icing conditions are present or were present during previous descent.  

ENG1 REV UNLOCKED MEL 78-30-01 

- Perform visual check of engine reverse cowls ENG1 SHUT DOWN NO GO

- Reset breaker FWC 1 & 2 on LH and RH reset panel  

ENG1 START FAULT NO GO 

- Starter - Starter valve - Ignition -etc- 

ENG1 START VALVE FAULT MEL 80-11-01

. Starter valve or starter 

ENG1 THR LEVER DISAGREE NO GO

- Disagree between Throttle Control Lever position and position detected by EEC  

- Reset breaker EIVMU 1 on LH reset panel 

ENG1 THR LEVER FAULT NO GO 

- Reset breaker EIVMU 1 on LH reset panel - Disagree between Throttle Control Lever Position and Position detected by EEC  

ENG2 A330ENG2 BLEED STATUS Apply ECAM procedure 

-Reset breaker EIVMU 2 on RH reset panel 

ENG2 CTL SYS FAULT NO GO 

-Recycle breaker FADEC A ENG 2 on panel 742VU position Q73 -Recycle breaker FADEC B ENG 2 on panel 722VU position D44 

ENG2 EGT OVERLIMIT Not applicable 

-Perform visual check of engine 

ENG2 EIU FAULT MEL 73-25-02 

-Reset breaker EIVMU 2 on LH reset panel -Reset breaker FCU 2 on LH reset panel 

ENG2 FADEC FAULT NO GO 

-Reset breaker SDAC 1 & 2 on LH and RH reset panel  -Reset breaker FCU 2 on LH reset panel 

ENG2 FADEC OVHT NO GO 

-Check for excessive heat near the EEC (nacelle anti-ice duct) 

ENG2 FADEC SYS FAULT NO GO 

-Reset breaker EIVMU 2 on LH reset panel -Recycle breaker FADEC A ENG 2 on panel 742VU position Q74 -Recycle breaker FADEC B ENG 2 on panel 722VU position D49 

27

Page 28: Ecam Warning

7/25/2019 Ecam Warning

http://slidepdf.com/reader/full/ecam-warning 28/28

 

ECAM WARNING A330ENG2 FIRE DET FAULT NO GO 

-Perform the bite test of the FDU with MCDU 

(ATA 26 Fire Prot -Engines -FDU -Test) 

ENG2 FIRE LOOP A FAULT MEL 26-12-01 

-Perform the bite test of the FOU with MCDU(ATA 26 Fire Prot -Engines -FDU -Test) 

ENG2 FIRE LOOP B FAULT MEL 26-12-01 -Perform the bite test of the FDU with MCDU 

(AT A 26 Fire Prot -Engines -FDU -Test) 

ENG2 FUEL FILTER CLOG NO GO 

-Check fuel pump filter -Check fuel pump filter differential switch 

ENG2 HP FUEL VALVE NO GO 

-Perform FADEC system static test with MCDU 

(AT A 70-80 Engine -EEC 2 -System test) 

ENG2 IGN A FAULT MEL 74-31-01 or

74-31-03-A 

-Reset breaker EIVMU 2 on RH reset panel 

ENG2 IGN B FAULT MEL 74-31-01 or74-31-03-A 

-Reset breaker EIVMU 2 on RH reset panel 

ENG2 IGN A+B FAULT MEL 74-31-01 or

74-31-03-A

-Reset breaker FWC 1 & 2 on LH and RH reset panel  

ENG2 MINOR FAULT MEL 73-25-01-A 

-Recycle breaker FADEC A ENG 2 on panel 742VU position Q74-Recycle breaker FADEC B ENG 2 on panel 722VU position D49 

ENG2 OIL FILTER CLOG NO GO or MEL 79-35-02-A 

-Check oil filter 

-Check oil filter differential switch ENG2 OIL HI TEMP NO GO 

-Check engine oil level 

ENG2 OIL LO TEMP Apply ECAM procedure

- Operational message - No further action required 

ENG2 OIL LO PRESS NO GO or MEL 79-34-01-A 

- Check engine oil level and check for leaks 

ENG2 REV FAULT MEL 78-30-01

- Reset breaker EIVMU 2 on RH reset panel 

ENG2 REV PRESSURIZED NO GO

Heat the TRDV (directional pilot valve) using hot air source to de-ice the press switch if icing conditions are present or were present during previous descent.  

ENG2 REV UNLOCKED MEL 78-30-01 

- Perform visual check of engine reverse cowls 

ENG2 SHUT DOWN NO GO

- Reset breaker FWC 1 & 2 on LH and RH reset panel  

ENG2 START FAULT NO GO 

- Starter - Starter valve - Ignition -etc- 

ENG2 START VALVE FAULT MEL 80-11-01

. Starter valve or starter 

ENG2 THR LEVER DISAGREE NO GO

- Disagree between Throttle Control Lever position and position detected by EEC  

- Reset breaker EIVMU 2 on RH reset panel 

ENG2 THR LEVER FAULT NO GO 

- Disagree between Throttle Control Lever position and position detected by EEC  