twiningconstruction.comtwiningconstruction.com/BCCC-Founders-Hall-Renovation/Plumbing Dwgs... ·...
Transcript of twiningconstruction.comtwiningconstruction.com/BCCC-Founders-Hall-Renovation/Plumbing Dwgs... ·...
COMMON ABBREVIATIONS
COMMON SYMBOLS
CONNECT TO EXISTING
EXISTING TO BE REMOVED
PLAN NORTH
SECTION IDA
H1.1 SHEET NO. WHERE SECTION IS
DIRECTIONAL VIEW OF SECTION
1 REVISION NUMBER
ELEVATION100.00'
1 KEYNOTE
EQUIPMENT TAG SHOWINGTYPE AND ID. SEE EQUIPMENTSCHEDULES FOR DETAILS
EXISTING TO REMAIN
REMOVE EXISTING
PROVIDE NEW
N
TYPEID
REVISION CLOUD
DETAIL ID1
H1.1 SHEET NO. WHERE DETAIL IS
101 ROOM/SPACE NO.
11 H1.1
DIRECTION OF VIEW
SHEET NO. WHERE EL. IS DRAWNELEVATION ID
A/E ARCHITECT/ENGINEER
AC ABOVE CEILING
ABV ABOVE
AFF ABOVE FINISHED FLOOR
AFI ARC-FAULT INTERRUPTER
AFR ABOVE FINISHED ROOF
ALT ALTERNATE
ATS AUTOMATIC TRANSFER SWITCH
ATC AUTOMATIC TEMPERATURECONTROL - COORDINATE LOCATION
C/G COUNTERTOP GFI
CD CORD DROP
CL CENTERLINE
CLG CEILING
CM CEILING MOUNT
COL COLUMN
CT COUNTERTOP HEIGHT-44" AFF UNOOR CURRENT TRANSFORMER
CR CORD REEL
DBF DOWN BELOW FLOOR
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DN DOWN
DW DISHWASHER
DWG DRAWING
EC ELECTRICAL CONTRACTOR
EL ELEVATION
ELEV ELEVATOR
EMER EMERGENCY
EO EMERGENCY ONLY (NORMALLYOFF)
EWC ELECTRIC WATER COOLER(PROVIDE GFI RECEPTACLE)
EQ EQUIPMENT, COORDINATELOCATION
EX EXISTING
FA FIRE ALARM
FBO FURNISHED BY OWNER
FLR FLOOR
FPC FIRE PROTECTION CONTRACTOR
FSC FOOD SERVICE CONTRACTOR
GC GENERAL CONTRACTOR
GFI GROUND-FAULT INTERRUPTER
GND GROUND
HC HVAC CONTRACTOR
HCP HANDICAPPED
HGT HEIGHT
HR HOUR
IR INFRARED
JB JUNCTION BOX
KES KITCHEN EQUIPMENT SUPPLIER
LV LOW-VOLTAGE
MC MECHANICAL CONTRACTOR
MCA MINIMUM CIRCUIT AMPACITY
MOCP MAXIMUM OVERCURRENTPROTECTION
MT MULTITECHNOLOGY
MO MICROWAVE OVEN
NA NOT APPLICABLE
NE NORMAL/EMERGENCY(NORMALLY ON)
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OFCI OWNER FURNISHED-CONTRACTOR INSTALLED
EQ FOR EQUIPMENT, COORDINATE LOCATION
P PEDESTAL
PC PLUMBING CONTRACTOR
PIR PASSIVE INFRARED
SE SERVICE ENTRANCE
SECT SECTION
SHT SHEET
SIM SIMILAR
SPD SURGE PROTECTION DEVICE
SPEC SPECIFICATION
SS SERVICE SINK
STD STANDARD
SUSP SUSPENDED
SB SMARTBOARD COORDINATE LOCATION
TL TASK LIGHT
TR TAMPER RESISTANT
TSTAT THERMOSTAT
TV FOR TV, COORDINATE LOCATION
TVSS TRANSIENT VOLTAGESURGE SUPPRESSER
UNO UNLESS NOTED OTHERWISE
US ULTRASONIC
USB 2 USB PORTS IN ADDITION TO RECEPTACLES
W/ WITH
W/O WITHOUT
W WALL-MOUNTED
WP WEATHERPROOF
AV
AW
ERW
ERW
AW
RW
RW
PLUMBING ABBREVIATIONS
PLUMBING SYMBOLS
N
EG
AR
VAC
AC
LCW
CA
DE
OX
WAGD
CO2
MA
NO2
TW
G
AT
BACKFLOW PREVENTER
SOLENOID VALVE
THERMOMETER
PRESSURE TEMPERATURERELIEF VALVE
STRAINER
PIPE CAP
PIPE RISE
PIPE DROP
DOMESTIC COLD WATER
DOMESTIC HOT WATER
DOMESTIC HOT WATER RETURN
TEPID WATER
SANITARY/WASTE UNDERGROUND
SANITARY/WASTE ABOVEGROUND
EXIST RAIN/STORM WATER UNDERGROUND
VENT
GAS
ACID WASTE UNDERGROUND
GATE VALVE
BALL/BUTTERFLY VALVE
WATER HAMMER ARRESTER
EXIST RAIN/STORM WATER ABOVEGROUND
EXIST SANITARY/WASTE UNDERGROUND
EXIST SANITARY/WASTE ABOVEGROUND
RAIN/STORM WATER UNDERGROUND
RAIN/STORM WATER ABOVE GROUND
EXIST GAS
LAB COLD WATER
ACID WASTE ABOVEGROUND
ACID VENT
COMPRESSED AIR
MEDICAL AIR
NITROUS OXIDE
OXYGEN
VACUUM
WASTE ANESTHESIA GAS DISPOSAL
EXIST DOMESTIC COLD WATER
NITROGEN
CARBON DIOXIDE
DEIONIZED WATER
ACETYLENE
ARGON
AIRTIGHT CONDUIT
TRAP PRIMER
FLOOR DRAIN
FLOOR SINK
GLOBE VALVE
CHECK VALVE
BALANCING VALVE WITHMEMORY STOP
UNION
ROOF DRAIN
PRESSURE GAUGE
GAS SHUT-OFF VALVE
MIXING VALVE
DIRECTION OF FLOW
EXPANSION JOINT
FLEXIBLE CONNECTION
MOMENT GUIDE
PIPE ANCHOR
SUPPORT CURB
SUPPORT CURB W/ANCHOR
EXIST DOMESTIC HOT WATER
EXIST DOMESTIC HOT WATER RETURN
A1 AIR STATION
PIPE CAP
PRESSURE REGULATORPR
THERMOSTATICRECIRCULATION VALVE
SELECTIVE DEMOLITION INCLUDES, BUT IS NOT LIMITED TO,REMOVAL AND LEGAL DISPOSAL OF EQUIPMENT AND SYSTEMSMADE OBSOLETE AND/OR REPLACED BY NEW WORK. SELECTIVEDEMOLITION INCLUDES REMOVAL AND RELOCATION ORRE-INSTALLATION, DISCONNECTIONS AND RE-CONNECTIONS OFSERVICES, SUPPORTS AND SUBSEQUENT FINAL SUPPORTS,TEMPORARY CAPPING, AND RE-ROUTING OF TEMPORARY SERVICESTO PERMIT NEW OR RENOVATION WORK TO PROCEED.
THE DEMOLITION WORK INDICATED ON THE DRAWINGS IS INTENDEDTO ASSIST THE CONTRACTOR AND GIVE GENERAL INFORMATION.NOT ALL DEMOLITION OR TEMPORARY CONNECTIONS ARE SHOWN.PRIOR TO SUBMITTING BID, THE CONTRACTOR SHALL VISIT THEPROJECT SITE AND REVIEW ORIGINAL DRAWINGS IF AVAILABLE.CONTRACTOR IS RESPONSIBLE TO DETERMINE THE FULL EXTENTOF SELECTIVE DEMOLITION, AND INCLUDE ALL REQUIREDSELECTIVE DEMOLITION WORK IN HIS BID, WHETHER OR NOTSPECIFICALLY SHOWN ON DRAWINGS. NO ADDITIONAL COSTS WILLBE GRANTED FOR SELECTIVE DEMOLITION. LEGALLY DISPOSE OFALL ITEMS AND MATERIALS, EXCEPT ANY ITEMS SPECIFICALLYDESIGNATED BY THE OWNER TO BE SALVAGED. REMOVE ANDPLACE THE DESIGNATED SALVAGED EQUIPMENT IN A LOCATIONDIRECTED BY THE OWNER.
REFER TO GENERAL CONSTRUCTION TRADE DEMOLITIONDRAWINGS AS WELL AS THE PLUMBING DRAWINGS FOR EXTENT OFTHE AREA TO BE DEMOLISHED AND FOR FIXTURES AND EQUIPMENTREQUIRED TO BE REMOVED DUE TO THE NEW CONSTRUCTION ANDRENOVATIONS.
PIPING MADE OBSOLETE BY THE NEW CONSTRUCTION SHALL BEREMOVED, INCLUDING INSULATION, HANGERS, AND SUPPORTS, ANDCAPPED ABOVE CEILINGS AT ACTIVE MAINS, BELOW FLOORS OR INWALLS SO THAT IT IS COMPLETELY CONCEALED AT THECOMPLETION OF THE PROJECT. DISCONNECT PIPING FROMOBSOLETE FIXTURES OR EQUIPMENT WHICH IS TO BE REMOVED BYOTHERS INCLUDING KITCHEN EQUIPMENT IF APPLICABLE AND CAPAND REMOVE PIPING IN SAME MANNER. EXISTING FLOOR DRAINSAND CLEANOUTS ARE TO REMAIN UNLESS OTHERWISE NOTED.PIPING REMOVED FROM THE EXISTING PLUMBING SYSTEM SHALLNOT BE USED IN THE INSTALLATION OF THE NEW SYSTEM.
IN ALL AREAS WHERE PATCHING IS REQUIRED, THE PLUMBINGCONTRACTOR SHALL PATCH THE SUB-SURFACE WHERE THE NEWSURFACE IS TO BE FINISHED BY THE GENERAL CONTRACTOR. THISSUB-SURFACE MUST BE PROVIDED SO THAT IS DOES NOT INHIBITTHE INSTALLATION OF OR AFFECT THE APPEARANCE OF THE NEWFINISH. IF A NEW FINISH WILL NOT BE PROVIDED BY THE GENERALCONTRACTOR, THE PLUMBING CONTRACTOR IS RESPONSIBLE TOPATCH THE SURROUNDING FINISHED SURFACE TO MATCHEXISTING. PATCH EXISTING OPENINGS FROM DEMOLISHED PIPINGIN FIRE RATED FLOORS AND WALLS AS REQUIRED TO MAINTAIN FIRERATING.
PLUMBING CONTRACTOR SHALL REMOVE/ REPLACE EXISTINGCEILING TILES AND GRID AS REQUIRED TO ACCOMPLISH INDICATEDPLUMBING WORK, UNLESS SPECIFICALLY INDICATED OTHERWISE.REFER TO THE ARCHITECTURAL DRAWINGS FOR FINISH TREATMENTOF SPACES.
WHERE NEW SANITARY, STORM OR WATER SERVICE PIPING ISINSTALLED BELOW NEW OR EXISTING WALL FOOTINGS, PROVIDESLEEVE AND ENCASE IN CONCRETE AS REQUIRED BY THESTRUCTURAL ENGINEER. VERIFY ALL EXISTING CONDITIONS ANDCOORDINATE EXACT LOCATION OF NEW OPENINGS FOR PIPINGREQUIRED TO PENETRATE EXISTING GRADE BEAMS ORFOUNDATION WALLS WITH THE STRUCTURAL ENGINEER.
REMOVE OBSOLETE VENTS THRU ROOF IN THEIR ENTIRETYINCLUDING ALL OBSOLETE VENT PIPING IN ACCESSIBLE CEILINGSPACE. PATCH RESULTING OPENINGS IN THE ROOF AS REQUIREDBY THE TYPE OF ROOF CONSTRUCTION . NEW INSULATION ANDROOFING WILL BE INSTALLED BY THE GENERAL CONTRACTOR.
TP
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
INV INVERT
IW INDIRECT WASTE
KW KILOWATT
LAV LAVATORY
LBS POUNDS
LMB LAUNDRY MACHINE BOX
MFG MANUFACTURER
MB MOP BASIN
MBH 1,000 BTU
MV MIXING VALVE
OD OUTSIDE DIAMETER
ORD OVERFLOW ROOF DRAIN
P PRESSURE GAUGE
PD PRESSURE DROP
PRV PRESSURE REDUCING VALVE
PSIG POUNDS PER SQUARE INCH GAUGE
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
RP RECIRCULATING PUMP
RPM REVOLUTIONS PER MINUTE
RWC RAINWATER CONDUCTOR
S SOIL LINE/STACK
SAN SANITARY SEWER
SK SINK
SH SHOWER
SI SOLIDS INTERCEPTOR
SS SERVICE SINK
T THERMOMETER
TD TRENCH DRAIN
TW TEPID WATER
UR URINAL
V VENT
VER VERTICAL
VTR VENT THRU ROOF
W WASTE
WC WATER CLOSET
WF WASHFOUNTAIN
WH WALL HYDRANT
WHA WATER HAMMER ARRESTER
WSV WATER SOLENOID VALVE
AD AREA DRAIN
AFG ABOVE FINISHED GRADE
AFR ABOVE FINISHED ROOF
AV ACID VENT
AW ACID WASTE
BFG BELOW FINISHED GRADE
BFP BACKFLOW PREVENTER
BLW BELOW
BOTT BOTTOM
BTUB BATHTUB
CA COMPRESSED AIR
CD CONDENSATE DRAIN
CFH CUBIC FEET PER HOUR
CIP CAST IRON PIPE
CO CLEAN OUT
CW COLD WATER
DF DRINKING FOUNTAIN
DIP DUCTILE IRON PIPE
DS DOWNSPOUT
DSN DOWNSPOUT NOZZLE
EEW EMERGENCY EYEWASH
ES EMERGENCY SHOWER
ESEW EMERGENCY SHOWER/EYEWASH
EWC ELECTRIC WATER COOLER
EXT EXTERIOR
FD FLOOR DRAIN
FDN FOUNDATION
FS FLOOR SINK
FT FEET
FT HD FEET OF HEAD
FTG FOOTING
GALV GALVANIZED
GH GROUND HYDRANT
GI GREASE INTERCEPTOR
GS GREASE SEPARATOR
GSV GAS SOLENOID VALVE
HB HOSE BIBB
HOR HORIZONTAL
HTG HEATING
HW HOT WATER
HWH HOT WATER HEATER
HWR HOT WATER RETURN
BACKWATER VALVE
1. PROVIDE ALL LABOR, MATERIAL, AND EQUIPMENT REQUIRED FOR THE COMPLETIONAND OPERATION OF ALL PLUMBING SYSTEMS IN THIS SECTION OF WORK INACCORDANCE WITH ALL APPLICABLE CODES.
2. THE PLUMBING DRAWINGS SHALL BE CONSIDERED AS BEING DIAGRAMMATIC AND ARENOT TO BE SCALED FOR THE ACCURATE CUTTING OF PIPE OR ITS EXACT PLACEMENT,BUT THEY SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONSTRUCTIONAND THE WORK OF OTHER TRADES WILL PERMIT. BEFORE ANY PIPING IS INSTALLED,CONFER WITH ALL OTHER CONTRACTORS IN ORDER TO ESTABLISH THE LOCATIONS OFTHEIR PIPING, CONDUIT, DUCTWORK, GRILLES, FOUNDATIONS, STRUCTURAL STEEL,LIGHTING FIXTURES AND OTHER EQUIPMENT SO AS TO AVOID INTERFERENCE.FAILURE TO COORDINATE SHALL NOT RESULT IN ANY ADDITIONAL EXPENSE TO THEOWNER.
3. LOCATIONS OF EXISTING PIPING ARE TAKEN FROM EXISTING RECORD DRAWINGS.VERIFY THE EXACT LOCATION OF ALL EXISTING LINES AND ALL INVERTS PRIOR TO THEINSTALLATION OF ANY NEW PIPING.
4. ALL FIXTURES SHALL BE COMPLETE AND INCLUDE SUPPLIES, STOPS, VALVES,FAUCETS, DRAINS, TRAPS, TAILPIECES, ESCUTCHEONS, ETC. TRAPS FOR ALLLAVATORIES AND SINKS SHALL BE REMOVABLE. LOCATE VALVES IN A READILYACCESSIBLE LOCATION. ALL EXPOSED WASTE AND SUPPLY PIPING LOCATED INFINISHED AREAS SHALL BE CHROME PLATED BRASS.
5. REFER TO THE RISER DIAGRAMS FOR ALL PIPE SIZES AND PIPING NOT SHOWN ON THEPLANS. UNLESS NOTED OTHERWISE ON THE DRAWINGS, ALL WASTE PIPING BELOWGRADE SHALL BE A MINIMUM OF 2" IN SIZE.
6. ALL MATERIALS SHALL BE NEW AND SHALL FIT THE SPACE AVAILABLE. VERIFYDIMENSIONS AT SITE.
7. ALL PIPING, APPARATUS, EQUIPMENT, ETC. SHALL BE PROPERLY SUPPORTED, BRACEDVERTICALLY AND HORIZONTALLY IN ACCORDANCE WITH APPLICABLE CODES AND ASREQUIRED TO PREVENT EXCESSIVE MOVEMENT DURING SEISMIC CONDITIONS.
8. REMOVE EXISTING CEILING TILES AND GRID OR PORTION OF EXISTING PLASTER ORGYPSUM BOARD AS REQUIRED TO OBTAIN ACCESS TO CEILING SPACE TOACCOMPLISH INDICATED PLUMBING WORK, UNLESS SPECIFICALLY INDICATEDOTHERWISE. PROVIDE ADDITIONAL TEMPORARY HANGERS/CABLES REQUIRED TOSUPPORT REMAINING CEILING, LIGHT FIXTURES, DEVICES, ETC. STORE EXISTINGCEILING TILES AND GRID IN A SAFE LOCATION AND RE-INSTALL ONCE THE WORK ISCOMPLETED. REPLACE DAMAGED TILES AND GRID WITH NEW TO MATCH EXISTING.PATCH/REPLACE DAMAGED PORTION OF PLASTER OR GYPSUM BOARD AND PAINT TOMATCH EXISTING. REMOVE ALL TEMPORARY FACILITIES ONCE THE WORK ISCOMPLETED. REFER TO THE ARCHITECTURAL DRAWINGS FOR FINISH TREATMENT OFSPACES.
9. ALL VALVES, CLEANOUTS, ETC., SHALL BE LOCATED AND INSTALLED TO PERMITACCESS FOR SERVICE WITHOUT DAMAGE TO BUILDING OR FINISHED MATERIALS.
10. PROVIDE CLEANOUTS ON ALL ACCESSIBLE TRAPS, AT THE BASE OF ALL SOIL/WASTESTACKS AND RAINWATER CONDUCTORS, AT EACH CHANGE OF DIRECTION OF PIPINGGREATER THAN 45 DEGREES AND LOCATED AT INTERVALS NOT TO EXCEED THEMAXIMUM PERMITTED BY THE APPLICABLE PLUMBING CODE AND AS INDICATED ONTHE DRAWINGS.
11. STERILIZE NEW DOMESTIC WATER PIPING AND PORTIONS OF THE EXISTING PIPINGTHAT HAVE BEEN ALTERED, EXTENDED, OR REPAIRED PRIOR TO USING. COMPLY WITHPURGING AND DISINFECTING PROCEDURES PRESCRIBED BY AUTHORITIES HAVINGJURISDICTION OR, IN THE ABSENCE OF PRESCRIBED METHOD, THE PROCEDURESDESCRIBED IN EITHER AWWA C651 OR AWWA C652, OR AS DESCRIBED IN THEAPPLICABLE PLUMBING CODE. FURNISH STERILIZATION REPORT TO ENGINEER UPONCOMPLETION.
12. ALL DOMESTIC WATER PIPING SHALL BE HUNG LEVEL WITHOUT PITCH.
13. COPPER PIPING SHALL BE PROTECTED AGAINST CONTACT WITH DISSIMILAR METALS.ALL HANGERS, SUPPORTS, ANCHORS, AND CLIPS SHALL BE COPPER OR COPPERPLATED. WHERE COPPER PIPING IS CARRIED ON IRON TRAPEZE HANGERS WITHOTHER PIPING, SATISFACTORY AND PERMANENT ELECTROLYTIC ISOLATION MATERIALSHALL PREVENT CONTACT WITH OTHER METALS.
14. WATER PIPING SHALL NOT BE RUN IN AREAS SUBJECT TO FREEZING TEMPERATURES.WATER PIPING IN EXTERIOR WALLS SHALL BE RUN ON CONDITIONED SIDE OF THEINSULATION.
15. ALL WATER PIPING SHALL BE INSULATED AND ALL WATER PIPING INSTALLED ABOVETHE CEILING SHALL BE BELOW THE BUILDING INSULATION.
16. PROVIDE DRAIN VALVES AT ALL LOW POINTS OF DOMESTIC WATER PIPING SYSTEMSFOR COMPLETE DRAINAGE AND INDICATE LOCATION OF SAME ON RECORDDRAWINGS.
17. PROVIDE VACUUM BREAKERS AS REQUIRED BY CODE.
18. ALL PLUMBING FIXTURES MUST BE VENTED IN ACCORDANCE WITH APPLICABLEPLUMBING CODE INCLUDING LOCAL CODES.
19. REFER TO THE ARCHITECTURAL PLANS FOR EXACT LOCATION OF DOORS, WINDOWS,FIXTURES, WALL DIMENSIONS, ETC.
20. THE ARCHITECTURAL DRAWINGS, INCLUDING INTERIOR ELEVATIONS, SHALL GOVERNTHE ARRANGEMENT, LOCATION, AND MOUNTING HEIGHTS OF ALL FIXTURES ANDEQUIPMENT, BUT NOT TO THE EXTENT OF PERMITTING ANY OMISSIONS OF FIXTURESOR EQUIPMENT SHOWN ON THE PLUMBING DRAWINGS. ANY DISCREPANCY BETWEENTHE DRAWINGS, OR BETWEEN THE DRAWINGS AND SPECIFICATIONS, SHALL BEBROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT AND ENGINEER.
21. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE SEALED WITH FIRERESISTANT CAULKING / MATERIALS. PATCH EXISTING OPENINGS FROM DEMOLISHEDPIPING IN FIRE RATED FLOORS AND WALLS AS REQUIRED TO MAINTAIN FIRE RATING.
22. COORDINATE FINAL FLOOR DRAIN LOCATIONS WITH ALL EQUIPMENT CONCRETE PADS,TOILET ROOM PARTITIONS, FURNITURE, ETC. OBTAIN EXACT LOCATIONS FROM ALLOTHER CONTRACTORS PRIOR TO INSTALLING DRAINS.
23. CAULK AROUND ALL PLUMBING FIXTURES INSTALLED. CAULK SHALL BENON-HARDENING, NON-YELLOWING, MILDEW RESISTANT SILICONE AND IN A COLORSELECTED BY THE ARCHITECT.
24. ANY REFERENCE TO "GC" OR "GENERAL CONTRACTOR" SHALL MEAN THEAPPROPRIATE GENERAL TRADES CONTRACTOR. THIS REFERENCE IS NOT TO OUTLINEWORK AMONG GENERAL TRADES CONTRACTORS, BUT TO NOTE WHAT WORK IS NOT APART OF THE PLUMBING CONTRACT.
25. ALL POTABLE WATER PIPING, DEVICES AND EQUIPMENT SHALL BE NSF-61 COMPLIANT.26. NO DEAD-LEG SUPPLY (3X PIPE DIA. MAXIMUM) SHALL BE IN PLACE UPON COMPLETION
OF PROJECT.
27. INCLUDE PRICE FOR 200' OF 2"COPPER DOMESTIC WATER PIPING INCLUDINGINSULATION AND HANGERS PER THE SPECIFICATION. THIS PRICE IS TO BE INCLUDEDIN BASE BID.
28. PROVIDE PRICE FOR 50' OF 4" CAST IRON DRAINAGE PIPE BELOW GRADE INCLUDINGSAWCUTTING EXCAVATION, BACKFILL, COMPACTION AND PATCHING OF CONCRETEFLOOR.
GENERAL PLUMBING NOTESGENERAL DEMOLITION NOTES
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P0.1LVE-14179
Cover Sheet
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
DRAWING LIST
F0.1 Cover SheetF2.0 Ground Floor PlanF2.1 First Floor PlanF2.2 Second Floor PlanF2.3 Third Floor Plan
P0.1 Cover SheetP1.0A Ground Floor Plan - DemolitionP2.0A Ground Floor Plan - Labs - DrainageP3.0A Ground Floor Plan - Labs - SupplyP1.1 First Floor Plan - DemolitionP1.2 Second Floor Plan - DemolitionP1.3 Roof Plan - DemolitionP1.0 Foundation Plan - DemolitionP2.1 First Floor Plan - Labs - DrainageP2.2 Second Floor Plan - Labs - DrainageP3.1 First Floor Plan - Labs - SupplyP3.2 Second Floor Plan - Labs - SupplyP2.3 Roof Plan - DrainageP2.0 Foundation Plan - Labs - DrainageP3.0 Foundation Plan - Labs - SupplyP8.1 Details and SchedulesP7.1 Riser Diagrams
H0.1 Cover SheetH1.0 Ground Floor Plan - DemolitionH1.1 First Floor Plan - DemolitionH1.2 Second Floor Plan - DemolitionH1.3 Third Floor Plan - DemolitionH2.0 Ground Floor Plan - HVACH2.1 First Floor Plan - HVACH2.2 Second Floor Plan - HVACH2.3 Third Floor Plan - HVACH7.0 DetailsH7.1 DetailsH8.0 SchedulesH8.1 SchedulesH5.1 Enlarged Plans & Sections-HVACH3.0 Ground Floor - HVAC - PipingH3.1 First Floor - HVAC - PipingH3.2 Second Floor - HVAC - PipingH7.2 DetailsH5.2 SectionsH5.3 SectionsH3.3 Third Floor - HVAC - PipingH8.2 SchedulesH8.3 SchedulesH7.3 DetailsH7.4 Details
E0.1 Cover SheetE1.0 Ground Floor Plan - DemolitionE1.1 First Floor Plan - DemolitionE1.2 Second Floor Plan - DemolitionE1.3 Third Floor Plan - DemolitionE2.0 Ground Floor Plan - LightingE2.1 First Floor Plan - LightingE2.2 Second Floor Plan - LightingE2.3 Third Floor Plan - LightingE3.0 Ground Floor Plan - PowerE3.1 First Floor Plan - PowerE3.2 Second Floor Plan - PowerE3.3 Third Floor Plan - PowerE4.0 Ground Floor Plan - Low-VoltageE4.1 First Floor Plan - Low-VoltageE4.2 Second Floor Plan - Low-VoltageE4.3 Third Floor Plan - Low-VoltageE7.1 Single Line DiagramsE8.1 SchedulesE5.1 Enlarged Kitchen PlanE7.2 DetailsE7.3 Teledata DetailsE8.2 SchedulesE8.3 SchedulesE8.4 SchedulesE8.5 Schedules
NO. ISSUE DATE: DESCRIPTION
3 4 5 6 7 8 9 10 11 12 13 14 15
L
K
H
G
F
E
D1
DC
B
A1
A
5.1
8.1
2.1 2.2
C1C2
C3
C4 C5
2"
4"EX. AW TOREMAIN
4"EX. AW TOREMAIN
4"EX. AW TOREMAIN
3"EX. AW TOREMAIN
4"EX. AWSTACK TOREMAIN
4"EX. AWSTACK TOREMAIN
8"EX. AW TOREMAIN
3"EX.AW TOREMAIN
3"EX.AW TOREMAIN
3"EX.AW TOREMAIN
3"EX.AW TOREMAIN
3"EX. AWSTACK TOREMAIN
1
6"W TOREMAIN
5"EX. WTOREMAIN
3"EX. AWTO REMAIN
2
2
2
22
2
2
2
2
2
2
22
2222
2
2
1
1
1
3
3
3
3
33
3
3
44
4
4
5
1
1
1
5"EX. WTOREMAIN
4
6
7
2.1 3 4 5 5.1 6 7 8 8.1 9 10 11 2.2 12 13 14 15
A
A1
B
CD
D1
E
F
G
H
K
L
6"EX. RWSTACK TOREMAIN
6"EX.RW TOREMAIN
4"EX. RWSTACK TOREMAIN
8"EX.RW TOREMAIN
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P1.0LVE-14179
Foundation Plan - Demolition
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
N
2'
Scale: 1/8" = 1'-0"
0 4' 8' 16'
FOUNDATION PLAN - DEMOLITION
NO. ISSUE DATE: DESCRIPTION
KeynotesKey Value Keynote Text
1 DISCONNECT AND REMOVE EXISTING SUPPLY PIPING IN ITS ENTIRETY.2 DISCONNECT AND REMOVE EXISTING WASTE AND SUPPLY PIPING SERVING SINK ON FLOOR ABOVE IN THEIR ENTIRETY.3 DISCONNECT AND REMOVE EXISTING GAS PIPING IN ITS ENTIRETY.4 DISCONNECT AND REMOVE EXISTING WASTE PIPING IN ITS ENTIRETY.5 DISCONNECT AND REMOVE EXISTING WASTE AND SUPPLY PIPING SERVING ELECTRIC WATER COOLER ON FLOOR ABOVE IN THEIR
ENTIRETY.6 PURGE EXISTING UNDERGROUND PROPANE TANK. FILL WITH PEA GRAVEL AND ABANDON IN PLACE.7 DEMOLISH EXISTING ROOF MOUNTED INTAKE/RELIEF ROOF CURB AND PATCH ROOF.
3 4 5 6 7 8 9 10 11 12 13 14 15
L
K
H
G
F
E
D1
DC
B
A1
A
5.1
8.1
2.1 2.2
C1C2
C3
C4 C5
PATIENT CARELAB
11
MEDICALASSISTANCE LAB
09
PHLEBOTOMYLAB
06
STAIR #3
S3-0
CORRIDOR #1
C1-0
M. TOIL
19
JC
18 STAIR #4
S4-0STORAGE
10
STORAGE
17
PATIENT CARELAB
16
STORAGE
12
?
?
W. TOIL
03
(2)G
(2)G
(1)G
(2)G
(4)G
(2)G
(2)G
(4)G
(2)G
(2)G
(4)G
(2)G
(4)G
(2)G
(4)G
(4)G
(2)G
(4)G
(4)G
(2)G
(4)G
(1)CW
(2)G
(4)G
(2)G
(2)G
(4)G
(2)G
(2)G
(4)G
(2)G
(4)G
(2)G
(4)G
(4)G
(2)G
(4)G
(4)G
(2)G
(4)G
(1)CW
11
2 22 3 3
3 3 3
3 3 3
3 3 3
33
3
3 3
3
3
33
3
3
3
3
3
3
3
3
33 3 3
3 3 3
3 3 3
3 3 (1)G
2
2
2
2
2
2
2
2
2
2
2
2
4
2
2
2
2
5
6
777
88
87
9
109
11
12
12
9
12
11
10
10
12
10
8
7
10
11
9
13
14
2.1 3 4 5 5.1 6 7 8 8.1 9 10 11 2.2 12 13 14 15
A
A1
B
CD
D1
E
F
G
H
K
L
5"EX. RWSTACK TOREMAIN
4"EX. RWSTACK TOREMAIN
15
EX. SUPPLY PIPINGTO REMAIN
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P1.0ALVE-14179
Ground Floor Plan -Demolition
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
N
2'
Scale: 1/8" = 1'-0"
0 4' 8' 16'
GROUND FLOOR PLAN - DEMOLITION
NO. ISSUE DATE: DESCRIPTION
KeynotesKey Value Keynote Text
1 DISCONNECT AND REMOVE EXISTING WASTE AND SUPPLY PIPING SERVING HOOD IN THEIR ENTIRETY.2 DISCONNECT AND REMOVE EXISTING SINK, FAUCET, HAND-HELD EMERGENCY EYEWASH, WASTE AND SUPPLY PIPING IN THEIR
ENTIRETY.3 DISCONNECT AND REMOVE EXISTING GAS OUTLETS AND SUPPLY GAS PIPING IN ITS ENTIRETY.4 DISCONNECT AND REMOVE EXISTING ELECTRIC WATER COOLER AND ALL ASSOCIATED COLD WATER SUPPLY PIPING IN ITS
ENTIRETY.5 DISCONNECT AND REMOVE EXISTING DISHWASHER, WASTE AND SUPPLY PIPING IN THEIR ENTIRETY.6 DISCONNECT AND REMOVE EXISTING WASTE AND SUPPLY PIPING SERVING STERILIZATION EQUIPMENT IN THEIR ENTIRETY.7 DISCONNECT AND REMOVE EXISTING SUPPLY BRANCHES, DROPS, AND RISERS IN THEIR ENTIRETY. CAP AT ACTIVE MAINS.8 DISCONNECT AND REMOVE EXISTING WASTE STACK, VENT STACK, COLD WATER, AND HOT WATER RISERS INSIDE OF CHASE IN
THEIR ENTIRETY.9 DISCONNECT AND REMOVE EXISTING SUPPLY PIPING IN ITS ENTIRETY.10 DISCONNECT AND REMOVE EXISTING GAS PIPING IN ITS ENTIRETY.11 DISCONNECT AND REMOVE EXISTING COMPRESSED AIR PIPING IN ITS ENTIRETY.12 DISCONNECT AND REMOVE EXISTING WASTE PIPING IN ITS ENTIRETY.13 DISCONNECT AND REMOVE EXISTING WASTE AND SUPPLY PIPING SERVING SINK ON FLOOR ABOVE IN THEIR ENTIRETY.14 DISCONNECT AND REMOVE EXISTING GAS, COMPRESSED AIR, AND VACUUM RISERS AND PIPING INSIDE CHASE IN THEIR ENTIRETY.15 DISCONNECT AND REMOVE EXISTING SINK, FAUCETS, WASTE AND SUPPLY PIPING IN THEIR ENTIRETY AND CAP AT ACTIVE MAINS.
3 4 5 6 7 8 9 10 11 12 13 14 15
L
K
H
G
F
E
D1
DC
B
A1
A
5.1
8.1
2.1 2.2
C1C2
C3
C4 C5
ELECTRICAL LAB
148
COMPUTER LAB
152
PROJECT ROOM
157
STEM LEARNINGCENTER
156
?
?
CLASSROOM
106
OFFICE
110A
CLASSROOM
115CLASSROOM
117
CLASSROOM
120
OFFICE
121
IDF
122
OFFICE
123
OFFICE
124
OFFICE
125
CONF. RM.
127
OFFICE
128
OFFICE
130
OFFICE
133
OFFICE
134
CLASSROOM
135
MECHANICAL
111
MECHANICAL
153
STAIR #3
S3-1
M. TOIL
159
STOR
160
STAIR #4
S4-1
?
?
CORRIDOR
C5-1
CORRIDOR
C4-1
UPPER LECTUREHALL
140
LECTURE HALL
141
LOBBY
142
STAIR #5
S5-1
?
?
?
?
CORRIDOR
C2-1
ELEV LOBBY
003
W. TOIL
102
MECH ROOM
101
W. TOIL
146
MECH PREP
155
MECHANICAL LAB
154
?
?
MECH STOR
151
OFFICE
110B
KITCHENETTE
110C
OFFICE
110F
OFFICE
110G
OFFICE
110H
OFFICE
110D
OFFICE
110E
STEM/PS OFFICES
110
OFFICE
122A
OFFICE
126
OFFICE
131
OFFICE
132A
OFFICE
132
?
?
OFFICE
129
ELECTRICAL LAB
148
LOBBY
142
(1)G
(2)G
(2)G
(2)G
(2)G
(2)G
(2)G
(2)G
(2)G
DW (1)G
(1)G
(1)VAC
(1)VAC
(1)VAC
DI WATER
1
2 32 3
44
4
4
44
4
4
4
4
5
5
5
5
5
5 5
6 6 6
7
8
9
EXISTING WASTE & VENTSTACK TO REMAIN
EXISTING WASTE & VENTSTACK TO REMAIN
EXISTING WASTE & VENTSTACK TO REMAIN
10 11
12
13
13
12
1111
13
11 1111
13
13
13
13
13
14
15
15
15
15
15
13
13
13
13
13
13
13
16 17
18
19
14
19
15
15
17
16
19
17
18
15
15
15
19
16
18
2.1 3 4 5 5.1 6 7 8 8.1 9 10 11 2.2 12 13 14 15
A
A1
B
CD
D1
E
F
G
H
K
L
5"EX. RWSTACK TOREMAIN
4"EX. RWSTACK TOREMAIN
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P1.1LVE-14179
First Floor Plan - Demolition
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
N
2'
Scale: 1/8" = 1'-0"
0 4' 8' 16'
FIRST FLOOR PLAN - DEMOLITION
NO. ISSUE DATE: DESCRIPTION
KeynotesKey Value Keynote Text
1 DISCONNECT AND REMOVE EXISTING ELECTRIC WATER COOLER AND ALL ASSOCIATED COLD WATER SUPPLY PIPING IN ITSENTIRETY.
2 DISCONNECT AND REMOVE EXISTING EMERGENCY SHOWER AND SUPPLY PIPING IN ITS ENTIRETY.3 DISCONNECT AND REMOVE EXISTING FLOOR DRAIN AND ALL ASSOCIATED WASTE PIPING. CUT AND PATCH EXISTING FLOOR AS
REQUIRED PER GENERAL DEMOLITION NOTES.4 DISCONNECT AND REMOVE EXISTING GAS OUTLETS AND SUPPLY GAS PIPING IN ITS ENTIRETY.5 DISCONNECT AND REMOVE EXISTING SINK, FAUCETS, WASTE AND SUPPLY PIPING IN THEIR ENTIRETY AND CAP AT ACTIVE MAINS.6 DISCONNECT AND REMOVE EXISTING VACUUM PIPING SERVING HOOD IN ITS ENTIRETY.7 DISCONNECT AND REMOVE EXISTING DISHWASHER, WASTE AND SUPPLY PIPING IN THEIR ENTIRETY.8 DISCONNECT AND REMOVE EXISTING SINK, FAUCETS, WASTE, SUPPLY AND DEIONIZED WATER PIPING IN THEIR ENTIRETY.9 DISCONNECT AND REMOVE EXISTING DEIONIZED WATER SYSTEM, TANKS, FILTER AND PIPING IN THEIR ENTIRETY.10 DISCONNECT AND REMOVE EXISTING GAS, COMPRESSED AIR, AND VACUUM RISERS AND PIPING INSIDE CHASE IN THEIR ENTIRETY.11 DISCONNECT AND REMOVE EXISTING WASTE STACK, VENT STACK, COLD WATER, AND HOT WATER RISERS INSIDE OF CHASE IN
THEIR ENTIRETY.12 EXISTING TANKS SHALL BE REMOVED AND HANDED OVER TO LAB TECHS.13 DISCONNECT AND REMOVE EXISTING WASTE AND SUPPLY PIPING SERVING SINK ON FLOOR ABOVE IN THEIR ENTIRETY.14 DISCONNECT AND REMOVE EXISTING VENT PIPING IN ITS ENTIRETY.15 DISCONNECT AND REMOVE EXISTING WASTE PIPING IN ITS ENTIRETY.16 DISCONNECT AND REMOVE EXISTING GAS PIPING IN ITS ENTIRETY.17 DISCONNECT AND REMOVE EXISTING COMPRESSED AIR PIPING IN ITS ENTIRETY.18 DISCONNECT AND REMOVE EXISTING VACUUM PIPING IN ITS ENTIRETY.19 DISCONNECT AND REMOVE EXISTING SUPPLY PIPING IN ITS ENTIRETY.
3 4 5 6 7 8 9 10 11 12 13 14 15
L
K
H
G
F
E
D1
DC
B
A1
A
5.1
8.1
2.1 2.2
C1C2
C3
C4 C5
COOKING ANDBAKING
CULINARYINSTRUCTIONAL
LAB
244
VOCATIONALCLASSROOM
247
COMPUTER LAB
250
ELEC.
221A
OFFICE
220
OFFICE
221
OFFICE
222
OFFICE
223
OFFICE
224
OFFICE
225
OFFICE
226
OFFICE
227
OFFICE
229
OFFICE
230
OFFICE
231
OFFICE
232
OFFICE
233
CLASSROOM
234
OFFICE
231A
CLASSROOM
212
CLASSROOM
214
CLASSROOM
216
CLASSROOM
218
OFFICE
205A
OFFICE
206
OFFICE
207
OFFICE
208
OFFICE
209
OFFICE
210
OFFICE
211
OFFICE
210A
OFFICE
205
CLASSROOM
204
ELEV VEST
203
W. TOIL
202
MECH ROOM
201
UPPER LECTUREHALL
239
CORRIDOR
C4-2
CORRIDOR
C5-2
CORRIDOR
C3-2 STAIR #4
S4-2
M. TOIL
255
STOR
256
CORRIDOR
C1-2
STAIR #5
S5-2
CORRIDOR #2
C2-2
?
?
W. TOIL
243
OBSERVATION /CONTROL ROOM
253C
?
?
?
?
OFFICE
228
STAIR #3
S3-2
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)A,G,V
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)A,G,V
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)G,V,A
(1)A,G,V
(2)G,V,A
(2)G,V,A
(2)G,V,A
(2)G,V,A
(2)G,V,A
(2)G,V,A
(2)G,V,A
(2)G,V,A
(2)G,V,A
(1)CW,G,V,A
(1)CW,G,V,A
CA TANK
He TANK
H TANK
He TANK
12
3
4
5
6
7
8
9
1 1
1 1 1 1 1 1
6
6
6
6
6
6
6
6
5
5
5
5
5
5
55
5
5
5
5
55
5
5
5
55
3
2
3
2
7 7
4
10 11 11
12 12
13 13
11
12
11
11
11
EXISTING WASTE/VENTSTACK TO REMAIN
EXISTING WASTE/VENTSTACK TO REMAIN
EXISTING WASTE/VENTSTACK TO REMAIN
2.1 3 4 5 5.1 6 7 8 8.1 9 10 11 2.2 12 13 14 15
A
A1
B
CD
D1
E
F
G
H
K
L
FOR CONTINUATION,REFER TOMECHANICAL RM 4XXON DWG P1.3.
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P1.2LVE-14179
Second Floor Plan -Demolition
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
N
2'
Scale: 1/8" = 1'-0"
0 4' 8' 16'
SECOND FLOOR PLAN - DEMOLITION
NO. ISSUE DATE: DESCRIPTION
KeynotesKey Value Keynote Text
1 DISCONNECT AND REMOVE EXISTING GAS, VACUUM, AIR OUTLETS AND ALL ASSOCIATED PIPING SERVING HOOD IN THEIR ENTIRETY.2 DISCONNECT AND REMOVE EXISTING EMERGENCY SHOWER AND SUPPLY PIPING IN ITS ENTIRETY.3 DISCONNECT AND REMOVE EXISTING FLOOR DRAIN AND ALL ASSOCIATED WASTE PIPING. CUT AND PATCH EXISTING FLOOR AS
REQUIRED PER GENERAL DEMOLITION NOTES.4 DISCONNECT AND REMOVE EXISTING GAS, VACUUM, AIR, COLD WATER AND ALL ASSOCIATED PIPING SERVING HOOD IN THEIR
ENTIRETY.5 DISCONNECT AND REMOVE EXISTING SINK, FAUCET, HAND-HELD EMERGENCY EYEWASH, WASTE AND SUPPLY PIPING IN THEIR
ENTIRETY.6 DISCONNECT AND REMOVE EXISTING GAS, VACUUM, AND AIR OUTLET STATIONS, COLD WATER OUTLETS, AND ALL ASSOCIATED
SUPPLY PIPING IN THEIR ENTIRETY.7 DISCONNECT AND REMOVE EXISTING GAS, VACUUM, AIR OUTLETS AND ALL ASSOCIATED SUPPLY PIPING IN THEIR ENTIRETY.8 DISCONNECT AND REMOVE EXISTING SINK, FAUCET, WASTE AND SUPPLY PIPING IN THEIR ENTIRETY.9 DISCONNECT AND REMOVE EXISTING ELECTRIC WATER COOLER AND ALL ASSOCIATED COLD WATER SUPPLY PIPING IN ITS
ENTIRETY.10 DISCONNECT AND REMOVE EXISTING GAS, COMPRESSED AIR, AND VACUUM RISERS AND PIPING INSIDE CHASE IN THEIR ENTIRETY.11 DISCONNECT AND REMOVE EXISTING WASTE STACK, VENT STACK, COLD WATER, AND HOT WATER RISERS INSIDE OF CHASE IN
THEIR ENTIRETY.12 EXISTING TANKS SHALL BE REMOVED AND HANDED OVER TO LAB TECHS.13 DISCONNECT AND REMOVE EXISTING VENT PIPING IN ITS ENTIRETY.
3 4 5 6 7 8 9 10 11 12 13 14 15
L
K
H
G
F
E
D1
DC
B
A1
A
5.1
8.1
2.1 2.2
C1C2
C3
C4 C5
CLASSROOM
306
CLASSROOM
307
CLASSROOM
308
CLASSROOM
309
CLASSROOM
310
CLASSROOM
311
CLASSROOM
312
CLASSROOM
313
CLASSROOM
314
CLASSROOM
315
CLASSROOM
316
CLASSROOM
317
CORRIDOR
C1-3
STAIR #5
S5-3
?
?
JC
304
MECH ROOM
305
MECH ROOM
320
VAC
CA
EX.FD
3"V FROM BLW
1 1
1
EXISTING VTR TOREMAIN
EXISTING VTR TOREMAIN
EXISTING VTR TOREMAIN
EXISTING VTR TOREMAIN
2
3
EXISTING VTRTO REMAIN
4
EXISTING VTR TOREMAIN
2.1 3 4 5 5.1 6 7 8 8.1 9 10 11 2.2 12 13 14 15
A
A1
B
CD
D1
E
F
G
H
K
L
5"EX. RW DN4"EX. RW DN
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P1.3LVE-14179
Roof Plan - Demolition
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
N
2'
Scale: 1/8" = 1'-0"
0 4' 8' 16'
ROOF PLAN - DEMOLITION
NO. ISSUE DATE: DESCRIPTION
KeynotesKey Value Keynote Text
1 DISCONNECT AND REMOVE EXISTING ROOF DRAIN AND ASSOCIATED PIPING DOWN TO AND INCLUDING FIRST ELBOW.2 DISCONNECT AND REMOVE EXISTING VENT THRU ROOF. CUT AND PATCH ROOF AS REQUIRED PER GENERAL DEMOLITION NOTES.3 DISCONNECT AND REMOVE EXISTING AIR COMPRESSOR, PIPING, AND ALL RELATED DEVICES IN THEIR ENTIRETY.4 DISCONNECT AND REMOVE EXISTING VACUUM PUMP PIPING AND ALL RELATED DEVICES IN THEIR ENTIRETY.
4 5 6 7 8 9 10
L
K
H
G
5.1 8.1
1
2"W FROMABV
2"W FROMSK-2 ABV
2" W2" W
2" W
2" W
2" W
2" W
2" W
2"W FROMSK-3 ABV
2"W FROMSK-4 ABV
2"W FROMSK-3 ABV
2"W FROMSK-1 ABV
2"W FROMSK-1 ABV
2"W FROMSK-1 ABV
2"W FROMSK-2 ABV
5" W5" W
6" W
3"EX. AW 3"EX. AW
3"EX. AW3"EX. AW
4"EX. AW 4"EX. AW 4"EX. AW 4"EX. AW
8"EX. AW
4"EX. AWFROM ABVTO REMAIN
1/8" / 1'-0"
2" W
1
1
1
1
1
1
2"W FROMLMB-1 ABV
2" W 1
EX. SANITARYMANHOLE
4" W
2
GI-1
3
4 5 5.1 6 7 8 8.1 9 10
G
H
K
L 4"EX. AWFROM ABV
4"W UP TOFCO
1/8" / 1'-0"
4" W
4" W
2"W FROMSK-1ABV
2" W1
1
3" V
4
REFER TO GREASEINTERCEPTOR DETAILON DWG. P8.1
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P2.0LVE-14179
Foundation Plan - Labs -Drainage
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
N
1'
Scale: 1/4" = 1'-0"
0 2' 4' 8'
FOUNDATION PLAN - LABS - DRAINAGE
NO. ISSUE DATE: DESCRIPTION
KeynotesKey Value Keynote Text
1 CONNECT NEW 2"WASTE TO EXISTING WASTE PIPING. VERIFY EXACT SIZE, INVERT, AND LOCATION OF CONNECTION POINT IN FIELD.2 CONNECT NEW 4"GREASE WASTE TO EXISTING WASTE/VENT STACK. VERIFY EXACT SIZE AND LOCATION OF CONNECTION POINT IN
FIELD.3 CONNECT NEW 4"WASTE TO EXISTING SANITARY MANHOLE. VERIFY EXACT SIZE, INVERT AND LOCATION OF CONNECTION POINT IN
FIELD.4 CONNECT NEW 3"VENT FROM GREASE INTERCEPTOR TO EXISTING WASTE AND VENT STACK IN CRAWL SPACE. VERIFY EXACT SIZE
AND LOCATION OF CONNECTION POINT IN FIELD.
4 5 6 7 8 9 10
L
K
H
G
5.1 8.1
PATIENT CARELAB
11
MEDICALASSISTANCE LAB
09
PHLEBOTOMYLAB
06
CORRIDOR #1
C1-0
M. TOIL
19
STORAGE
10
STORAGE
17
PATIENT CARELAB
16
STORAGE
12
W. TOIL
032"W FROM ABV
2" W
2"W DBF. FOR VENT PIPING,REFER TO AIR ADMITTANCEVALVE DETAIL ON DWG. P8.1.
2"W DBF
EX. WASTE ANDVENT STACK TOREMAIN
EX. WASTE ANDVENT STACK TOREMAIN
SK-3
SK-3
SK-1
SK-1
SK-1 SK-1
SK-2SK-2
SK-4
M. TOIL
19
STORAGE
04
2"W DBF. FOR VENT PIPING,REFER TO AIR ADMITTANCEVALVE DETAIL ON DWG. P8.1.
2"W DBF. FOR VENT PIPING,REFER TO AIR ADMITTANCEVALVE DETAIL ON DWG. P8.1.
2"W DBF. FOR VENT PIPING,REFER TO AIR ADMITTANCEVALVE DETAIL ON DWG. P8.1.
2"W DBF. FOR VENT PIPING,REFER TO AIR ADMITTANCEVALVE DETAIL ON DWG. P8.1.
2"W DBF. FOR VENT PIPING,REFER TO AIR ADMITTANCEVALVE DETAIL ON DWG. P8.1.
2"W DBF. FOR VENT PIPING,REFER TO AIR ADMITTANCEVALVE DETAIL ON DWG. P8.1.
2"W DBF 2"W DBF
2"W DBF, 2"V UP TO AIRADMITTANCE VALVE.
LMB-1
1/8" / 1'-0"2"V UP
2"V UP
2" V
FCO
FCO
GI-1
EX. WASTE ANDVENT STACK TOREMAIN
4 5 5.1 6 7 8 8.1 9 10
G
H
K
L
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P2.0ALVE-14179
Ground Floor Plan - Labs -Drainage
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
NO. ISSUE DATE: DESCRIPTION
N
1'
Scale: 1/4" = 1'-0"
0 2' 4' 8'
GROUND FLOOR PLAN - LABS - DRAINAGE
4 5 6 7 8 9 10
L
K
H
G
5.1 8.1
ELECTRICAL LAB
148
COMPUTER LAB
152
PROJECT ROOM
157
STEM LEARNINGCENTER
156
MECHANICAL
153
?
?
CORRIDOR
C5-1
MECH PREP
155
MECHANICAL LAB
154
?
?
MECH STOR
151
2"W FROMABV
2"W DBF
2" W 1/8" / 1'-0"
2"VUP 2" W
2" V
2"V UP
SK-1
SK-1
SK-5
1 1/2" W
MEETING RM 4
161
STG
156A
INSTALL WASTE PIPINGTHRU REAR OF BASECABINETS, TIGHT TOWALL.
3" W
3" W
3" W
3" W
3" W
3" W
2" W
3" W
3" W
3" W
2" W
VERTICAL 2"VENT UP OFFWASTE PIPING.
VERTICAL 2"VENT UP OFFWASTE PIPING.
3"W DNFROM FD-1ABV
3"W DNFROM FD-1ABV
3"W DNFROM FS-1ABV
2"W DNFROM ABV
2"W DNFROM ABV
3"W DNFROM FS-1ABV
3"W DNFROM FD-1ABV
3"W DNFROM FS-1ABV
3"W DNFROM FD-1ABV
3"W DNFROM FS-1ABV
2"V FROMBLW
2" V
2"VFROMBLW
3" W
3" W
3" W
EX. WASTE ANDVENT STACK
EX. WASTE ANDVENT STACK TOREMAIN
EX. WASTE ANDVENT STACK
1
4 5 5.1 6 7 8 8.1 9 10
G
H
K
L
2
3
2" W
2" V
3"W DNFROM FS-1ABV
3"W DNFROM FS-1ABV
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P2.1LVE-14179
First Floor Plan - Labs -Drainage
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
NO. ISSUE DATE: DESCRIPTION
KeynotesKey Value Keynote Text
1 CONNECT NEW 3"GREASE WASTE TO EXISTING WASTE/VENT STACK. VERIFY EXACT SIZE AND LOCATION OF CONNECTION POINT INFIELD.
2 CONNECT NEW 2"VENT TO EXISTING WASTE AND VENT STACK. VERIFY EXACT SIZE AND LOCATION OF CONNECTION POINT IN FIELD.3 CONNECT NEW 2"WASTE TO EXISTING WASTE AND VENT STACK. VERIFY EXACT SIZE AND LOCATION OF CONNECTION POINT IN FIELD.
N
1'
Scale: 1/4" = 1'-0"
0 2' 4' 8'
FIRST FLOOR PLAN - LABS - DRAINAGE
KETTLE, COUNTER-TOPE8 2"
ITEMNO.
DESCRIPTION
KITCHEN FIXTURE CONNECTION SCHEDULE
E17 14" 2"
DISHTABLE, STRAIGHT
18"
14"
--
E19 14" 1-1/2"14"
OVEN, CONVECTIONE12 18" --
-
-
-
-
1/2"
1/2"
COMBI-OVENE13 1-1/2"18" --
FILTER SYSTEM, STEAMERE14 -60" --
-
-
E20 16" 1-1/2"
SINK, HAND, WALL-MOUNT
16"
E22 -
WAREWASHER, DOOR TYPE, HIGH TEMP
18"
-
1-1/2"
1/2"
SINK, SCULLERY, 2-COMPARTMENTE25 14" 2"14" -1/2"
SINK, SCULLERY, 3-COMPARTMENT
CWROUGH-IN
HEIGHT
HWSIZE(B)
IDWSIZE(C)
DWSIZE(D)
HWROUGH-IN
HEIGHT
-
-
-
-
-
-
-
20"
-
DWROUGH-IN
HEIGHT
1/2"
(2) 1/2"
1/2"
1/2"
1/2"
CWSIZE(B)
1/2"
1/2"
1/2"
1/2"
-
18"1/2"
E20c - -12"WAREWASHER DRAIN TEMPERING -- -1/2"
E8
E1
E1
E4
E1
E1
E1
E1
E23
E4
E1
E8
E12
E1
E27
E15
E10
E11
E9
E28
E20
E13
24X60
24X6024X60
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
4 5 6 7 8 9 10
L
K
H
G
5.1 8.1
COOKING ANDBAKING
CULINARYINSTRUCTIONAL
LAB
244
VOCATIONALCLASSROOM
247
COMPUTER LAB
250
CORRIDOR
C5-2
CORRIDOR
C3-2
M. TOIL
255
STOR
256
OBSERVATION /CONTROL ROOM
253C
?
?
2" V
EX. WASTE DN,WASTE VENTTHRU ROOF
EX. VENT UPTO EX. 3"VTR
SK-2
STOR
256
SIM. LOBBY
253
ICU
253B
SIMULATION
253D
STORAGE
253F
SIMULATION
253E
SIMULATION
253A
FS-1
FS-1
FS-1
FD-1
FD-1
FD-1
FD-1
FS-1
FCO
FCO
FCO
2"W DBF,1-1/2"V UP
2"V FROM BLW1
2"V FROM BLW
2"W DBF,2"V UP
2"W DBF,2"V UP
2"V FROMBLW
1
2" V
2" V1
2" V
2" V
EX. VENT UPTO EX. 3"VTR
EX. VENT UPTO EX. 3"VTR
EX. WASTE DN,WASTE VENTTHRU ROOF
4 5 5.1 6 7 8 8.1 9 10
G
H
K
L
FS-1
FS-1
1/8" / 1'-0"
4" RW
2
2
34
3
5
4"RW FROMRD-1 ABV
4"RW FROMRD-1 ABV4"RW FROM
RD-1 ABV
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P2.2LVE-14179
Second Floor Plan - Labs -Drainage
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
NO. ISSUE DATE: DESCRIPTION
KeynotesKey Value Keynote Text
1 CONNECT NEW 2"VENT TO EXISTING VENT PIPING IN CEILING SPACE. VERIFY EXACT SIZE AND LOCATION OF CONNECTION POINT INFIELD.
2 CONNECT NEW 4"RW PIPING TO EXISTING RAINWATER PIPING IN CEILING. VERIFY EXACT SIZE, INVERT AND LOCATION OFCONNECTION POINT IN FIELD.
345 CONNECT NEW 4"RW PIPING TO EXISITING RAINWATER STACK IN MEN'S TOILET ROOM 255 CHASE. VERIFY EXACT SIZE, INVERT, AND
LOCATION OF CONNECTION POINT IN FIELD. CUT AND PATCH EXISTING WALL AS REQUIRED PER THE GENERAL DEMOLITION NOTES.
N
1'
Scale: 1/4" = 1'-0"
0 2' 4' 8'
SECOND FLOOR PLAN - LABS - DRAINAGE
3 4 5 6 7 8 9 10 11 12 13 14 15
L
K
H
G
F
E
D1
DC
B
A1
A
5.1
8.1
2.1 2.2
C1C2
C3
C4 C5
EX. VTR TOREMAIN
11
1
RD-1
EX. VTR TOREMAIN
EX. VTR TOREMAIN
RD-1
RD-1
EX. VTR TOREMAIN
EX. VTR TOREMAIN
EX. VTR TOREMAIN
2.1 3 4 5 5.1 6 7 8 8.1 9 10 11 2.2 12 13 14 15
A
A1
B
CD
D1
E
F
G
H
K
L
EX. VTR TOREMAIN
RD-1 RD-1RD-1
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P2.3LVE-14179
Roof Plan - Drainage
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
N
2'
Scale: 1/8" = 1'-0"
0 4' 8' 16'
ROOF PLAN - DRAINAGE
NO. ISSUE DATE: DESCRIPTION
KeynotesKey Value Keynote Text
1 PROVIDE NEW RD-1 AND CONNECT NEW RW PIPING TO EXISTING RAINWATER CONDUCTOR DOWN TO AND INCLUDING FIRST ELBOWIN CEILING SPACE. PROVIDE INSULATION ON DRAIN BODY AND PIPING AS REQUIRED.
P.C. TO FURNISH AND HAND OVER ROOF DRAINS TO G.C. FOR INSTALLATION.P.C. IS RESPONSIBLE FOR NEW PIPE CONNECTIONS FOR UNDERSIDE OFROOF.
4 5 6 7 8 9 10
L
K
H
G
5.1 8.1
1/2" HWR1/2" HW
1/2" CW1/2" CW1/2" HW
1/2" HW
1/2" CW
1/2" CW
1/2" HW
1/2" HWR3/4" HW3/4" CW
1/2" HWR1/2" HW
1/2" CW
1/2" CW
1/2" HWR1/2" HW
1/2" HW1/2" CW
1/2" HWR3/4" HW3/4" CW
1/2" HW
1/2" CW
1/2" HWR
1/2" CW1/2" HW
1/2" HWR
1/2"CW & HW UP1/2"CW & HW UP1/2"CW & HW UP
1/2"CW & HW UP
1/2"CW & HW UP
1/2"CW & HW UP
1/2"CW & HW UP1/2"CW & HW UP
1/2"CW & HW UP
1/2"CW & HW UP
1/2"CW & HW FROM ABV
1/2"HWR UP 1/2"HWR UP 3/4"CW & HW FROM ABV
1/2"HWR UP
1/2"HWR UP
3/4" CW
3/4" HW
3/4"CW & HWFROM ABV
4 5 5.1 6 7 8 8.1 9 10
G
H
K
L
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P3.0LVE-14179
Foundation Plan - Labs -Supply
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
N
1'
Scale: 1/4" = 1'-0"
0 2' 4' 8'
FOUNDATION PLAN - LABS - SUPPLY
NO. ISSUE DATE: DESCRIPTION
4 5 6 7 8 9 10
L
K
H
5.1 8.1
PATIENT CARELAB
11
MEDICALASSISTANCE LAB
09
PHLEBOTOMYLAB
06
CORRIDOR #1
C1-0
STORAGE
10
STORAGE
17
PATIENT CARELAB
16
STORAGE
12
3/4" CW
3/4" HW1/2" HWR
1/2" HWR1/2" HW1/2" CW
1/2"CW & HW FROMBLW
1/2"CW & HW FROMBLW
1/2"CW & HW FROMBLW
1/2"CW & HW FROMBLW
1/2"CW & HW FROMBLW
1/2"CW & HW UP
1/2"CW & HW FROMBLW
1/2"CW & HW FROMBLW
1/2"CW & HW FROMBLW
1/2"CW & HW FROMBLW1"CW, 1" HW &
1/2"HWR UP1/2" CW, HW &HWR DN
3/4" CW & HW DN1/2"HWR FROM BLW
1/2" CW, HW &HWR DN
3/4"CW & HW, AND1/2"HWR UP
1/2"CW & HWFROM BLW TOSERVE LMB-1
11212
31
INSTALL SUPPLY RISERS ALONGREAR OF BASE CABINET
INSTALL SUPPLY RISERS ALONGREAR OF BASE CABINET
INSTALL SUPPLY RISERS ALONGREAR OF BASE CABINET
INSTALL SUPPLY RISERS ALONGREAR OF BASE CABINET
INSTALL SUPPLY RISERS ALONGREAR OF BASE CABINET
INSTALL SUPPLY RISERS ALONGREAR OF BASE CABINET
INSTALL SUPPLY RISERS ALONGREAR OF BASE CABINET
LMB-1
SK-3
SK-1
SK-1
SK-3 SK-1 SK-1
SK-2SK-2
SK-4
1/2"CW & HW DN1/2"HWR FROM BLW
EXISTING SUPPLYMAINS IN CEILINGSPACE
MV-1 MV-1 MV-1
EXISTING SUPPLYMAINS IN CEILINGSPACE
4 5 5.1 6 7 8 8.1 9 10
H
K
L
EEW-1
EEW-1 EEW-1 EEW-1
MV-1
2.1 3 4
A1
B
C
D
1 1/2" CW
2 1/2" CW
?
?
BFP-1
4
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P3.0ALVE-14179
Ground Floor Plan - Labs -Supply
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
N
1'
Scale: 1/4" = 1'-0"
0 2' 4' 8'
GROUND FLOOR PLAN - LABS - SUPPLY
NO. ISSUE DATE: DESCRIPTION
KeynotesKey Value Keynote Text
1 CONNECT NEW 1/2"CW, HW AND HWR TO EXISTING SUPPLY MAINS IN CEILING SPACE. VERIFY EXACT SIZE AND LOCATION OFCONNECTION POINTS IN FIELD.
2 CONNECT NEW 3/4"CW & HW, 1/2"HWR TO EXISTING SUPPLY MAINS IN CEILING SPACE. VERIFY EXACT SIZE AND LOCATION OFCONNECTION POINTS IN FIELD.
3 CONNECT NEW 1"CW & HW, 1/2"HWR TO EXISTING SUPPLY MAINS IN CEILING SPACE. VERIFY EXACT SIZE AND LOCATION OFCONNECTION POINTS IN FIELD.
4 PROVIDE 1-1/2"CW CONNECTION FOR H.C.
N
1'
Scale: 1/4" = 1'-0"
0 2' 4' 8'
ENLARGED PLAN - MECH RM 21 - SUPPLY
4 5 6 7 8 9 10
L
K
H
G
5.1 8.1
ELECTRICAL LAB
148
COMPUTER LAB
152
PROJECT ROOM
157
STEM LEARNINGCENTER
156
MECHANICAL
153
M. TOIL
159
?
?
CORRIDOR
C5-1
W. TOIL
146
MECH PREP
155
MECHANICAL LAB
154
?
?
MECH STOR
151
?
?
3/4"CW & HW FROMBLW & 1/2"HWR DN
1/2"CW & HW UP
1/2" CW1/2" HW
1/2" HWR
1/2"CW & HWFROM BLW
INSTALL SUPPLY RISERS ALONGREAR OF BASE CABINET
1"CW & HW FROMBLW & 1/2"HWR DBF
SK-1
SK-1
SK-5
MEETING RM 4
161
MEETING RM 3
118
STG
156A
?
?
1"CW & HW UP &1/2"HWR FROM ABV
MV-1
MV-1
4 5 5.1 6 7 8 8.1 9 10
G
H
K
L
EEW-1MV-1
EEW-1
EEW-1
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P3.1LVE-14179
First Floor Plan - Labs -Supply
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
N
1'
Scale: 1/4" = 1'-0"
0 2' 4' 8'
FIRST FLOOR PLAN - LABS - SUPPLY
NO. ISSUE DATE: DESCRIPTION
KeynotesKey Value Keynote Text
KETTLE, COUNTER-TOPE8 2"
ITEMNO.
DESCRIPTION
KITCHEN FIXTURE CONNECTION SCHEDULE
E17 14" 2"
DISHTABLE, STRAIGHT
18"
14"
--
E19 14" 1-1/2"14"
OVEN, CONVECTIONE12 18" --
-
-
-
-
1/2"
1/2"
COMBI-OVENE13 1-1/2"18" --
FILTER SYSTEM, STEAMERE14 -60" --
-
-
E20 16" 1-1/2"
SINK, HAND, WALL-MOUNT
16"
E22 -
WAREWASHER, DOOR TYPE, HIGH TEMP
18"
-
1-1/2"
1/2"
SINK, SCULLERY, 2-COMPARTMENTE25 14" 2"14" -1/2"
SINK, SCULLERY, 3-COMPARTMENT
CWROUGH-IN
HEIGHT
HWSIZE(B)
IDWSIZE(C)
DWSIZE(D)
HWROUGH-IN
HEIGHT
-
-
-
-
-
-
-
20"
-
DWROUGH-IN
HEIGHT
1/2"
(2) 1/2"
1/2"
1/2"
1/2"
CWSIZE(B)
1/2"
1/2"
1/2"
1/2"
-
18"1/2"
E20c - -12"WAREWASHER DRAIN TEMPERING -- -1/2"
E8
E1
E1
E4
E1
E1
E1
E1
E23
E4
E1
E8
E12
E1
E27
E15
E10
E11
E9
E28
E20
E13
24X60
24X6024X60
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
Mag
naW
ave
TM
4 5 6 7 8 9 10
L
K
H
G
5.1 8.1
COOKING ANDBAKING
CULINARYINSTRUCTIONAL
LAB
244
VOCATIONALCLASSROOM
247
COMPUTER LAB
250
CORRIDOR
C5-2
CORRIDOR
C3-2
M. TOIL
255W. TOIL
243
OBSERVATION /CONTROL ROOM
253C
1/2"CW & HW FROMBLW
SK-2
SIM. LOBBY
253
ICU
253B
SIMULATION
253D
STORAGE
253F
SIMULATION
253E
SIMULATION
253A
1/2" HWR
1" HW
1" CW
1"CW & HW FROMBLW, 1/2"HWR DBF
3/4" CW3/4" HW
1/2" HWR
3/4" CW3/4" HW
1/2" HWR
3/4" HW
3/4" CW
3/4" CW
3/4" HW
4 5 5.1 6 7 8 8.1 9 10
G
H
K
L
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P3.2LVE-14179
Second Floor Plan - Labs -Supply
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
N
1'
Scale: 1/4" = 1'-0"
0 2' 4' 8'
SECOND FLOOR PLAN - LABS - SUPPLY
NO. ISSUE DATE: DESCRIPTION
GROUND FLOOR
CEILING
FIRST FLOOR
CEILING
SECOND FLOORFS-1
SK-1
FS-1FS-1FS-1
SK-1
FS-1FS-1CO FD-1 FD-1 CO CO FD-1 FD-1
CEILING
ROOF
EX. VTR EX. VTR
2" 2"2" 2"
3" 3" 3"3" 3"
3"
EXISTINGSANITARYMANHOLE
GI-14"
4"
3"COCO
3"
GROUND FLOOR
CEILING
FIRST FLOOR
CEILING
SECOND FLOOR
CEILING
ROOF
SK-3SK-1SK-1
EX. 3"
SK-4SK-3
EX. 6" EX. 8"
EX. 3"EX. 4"
EX. 4"
EX. VENT STACK
LMB-1
SK-1
EX. 4"
SK-2 SK-2SK-1
EX. 8"
EX. VTR EX. VTR
SK-5
SK-2
EX. VTR
SK-1SK-1
EX. VENT STACK
EX. 4"AW STACK
EX. 3"EX. 4"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
1611
090906
154155 157
253B
2"
244
KITCHEN RISER DIAGRAM - DRAINAGENO SCALE
RISER DIAGRAM - DRAINAGENO SCALE
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P7.1LVE-14179
Riser Diagrams
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
NO. ISSUE DATE: DESCRIPTION
FLOOR
COUNTERTOP
1. EXCAVATE TO THE REQUIRED DEPTH, LENGTH AND WIDTH IN ACCORDANCE WITH OSHA PRACTICES, PROVIDE 12" OF FREE SPACE AROUND THE UNIT AT THE BOTTOM.2. INSTALL & LEVEL 6" LAYER OF PEA GRAVEL OR APPROVED EQUIVALENT BACKFILL COMPACTED TO 98% S.P.D.3. IF USING APPROVED BACKFILL MATERIAL INSTEAD OF PEA GRAVEL, INSTALL GEOTEXTILE FILTER FABRIC TO PREVENT MIGRATION AND COMPACT BACKFILL IN 6" TO 8" LAYERS TO 98% S.P.D.4. INSTALL AND LEVEL TANK5. FILL THE SEPARATOR WITH WATER UP TO THE HEIGHT OF THE BUOYANCY SLAB6. POUR CONCRETE READY MIX ANTI-BUOYANCY SLAB 12" ALL AROUND THE SEPARATOR CELLS TO HEIGHT OF BUOYANCY SLAB.7. FILL SEPARATOR WITH WATER UP TO THE INLET/OUTLET PIPES.8. BACKFILL UP TO THE INLET/OUTLET PIPES WITH PEA GRAVEL OR APPROVED EQUIVALENT IN 6" TO 8" LAYERS. COMPACT BACKFILL TO 98% S.P.D.9. CONNECT THE INLET, OUTLET AND VENT PIPING.10. INSTALL EXTENSION COLLAR AND FIBERGLASS SIKAFLEX CAULKING FOR WATERTIGHT SEAL11. BACKFILL WITH PEA GRAVEL, COURSE SAND OR APPROVED EQUIVALENT TO MINIMUM 18" ABOVE THE BASE OF THE EXTENSION COLLAR FOR TRAFFIC LOADING SLAB FOR TRAFFIC CONDITIONS OR SURFACE COVER OF PAVEMENT SUBSURFACE COMPACT BACKFILL TO 98% S.P.D.12. INSTALL COVER13. POUR REINFORCED BEARING SLAB AT SURFACE GRADE. FOR TRAFFIC LOADING CONSULT WITH STRUCTURAL ENGINEER.14. US PATENT #5,746,912; CDN PATENT #2,195,822
NOTES:
INSTALL FLOW CONTROLAT INLET; USE ADAPTORSWHERE REQUIRED
12"
MIN. 6" PEA GRAVELOR APPROVED BACKFILLCOMPACTED TO 98% SPD
3000 psi CONCRETE READY MIX POUR 12" ALL AROUNDBASE OF UNIT TO HEIGHT OF BUOYANCY SLAB(82" LENGTH X 52" WIDTH X HEIGHT OF SLAB)
19"20"
LENGTH 62" WIDTH 32"
INLETOUTLET
PEA GRAVEL ORAPPROVEDEQUIVALENTCOMPACTED TO98% SPD
VENTING PER LOCALPLUMBING CODE
TWO VENT PORTS SUPPLIEDONE CAN BE CAPPED.
EXTENSION COLLAR ASREQUIRED
24" DIA. LIGHTDUTY FRAMECOVER
TERMINATE WITHVENT CAP
GRADEC/O C/O
(PROCEPTOR SEPARATORS MUST BE INSTALLEDIN ACCORDANCE WITH ALL RELEVANT FEDERAL,PROVINCIAL/STATE, AND LOCAL CODES INCLUDINGLOCAL PLUMBING CODE)* ACTUAL HEIGHT MAY VARY SLIGHTLY.
REFER TO FLOORPLANS FOR 3"VENTCONTINUATION
GREASE TRAPPROCEPTOR, Mo. GMC-100 WITH EXTENSION IF REQUIRED AND FLOWCONTROL FITTING. 42 GALLON GREASE CAPACITY, 100 GPM FLOW RATE.GREASE TRAP DESIGN SHALL BE IN ACCORDANCE WITH SEWERAUTHORITY REQUIREMENTS.
NO SCALE
ADA COMPLIANT SINK (SK-1)ELKAY LUSTERTONE, MODEL ELUHAD211555, SINGLE BOWL, 18 GAUGE TYPE 304STAINLESS STEEL, 5 1/2" DEEP, UNDERMOUNT WITH:a. CHICAGO MODEL 895-317GN8AE29VAB DECK MOUNTED SINK FAUCET WITH 8"
RIGID/SWING PLAIN END GOOSENECK SPOUT WITH 2.2 GPM LAMINAR FLOWCONTROL DEVICE IN SPOUT, 4" WRIST BLADE HANDLES AND QUATURNOPERATING CARTRIDGE;
b. LK-99 STAINLESS STEEL DRAIN OUTLET FITTING WITH CONICAL STRAINERBASKET WITH BALL BEARING LOCKING STEM AND RUBBER STOPPER AND 1 1/2"O.D. STAINLESS STEEL TAILPIECE;
c. McGUIRE CHROME PLATED HEAVY CAST BRASS P-TRAP TO WALL WITHCLEANOUT;
d. McGUIRE E-Z TURN MINI BALL VALVE STOPS WITH PREMIERE LINE HEAVYFLEXIBLE CHROME PLATED SUPPLY RISERS. (SWEAT WITH EXTENSION TOCOMPRESSION OR COMPRESSION TO COMPRESSION PREFERRED).
e. FURNISH A TEMPLATE TO THE GENERAL CONTRACTOR FOR THE ACCURATECUTTING OF THE COUNTERTOP AND COORDINATE EXACT LOCATION OFOPENING IN CASEWORK TO ENSURE SINK INSTALLATION WILL BE ADACOMPLIANT.
NOTE: INSULATE ALL EXPOSED DRAIN AND WATER PIPING ON ADA COMPLIANTFIXTURES WITH MODEL #102 E-Z LAV GUARD INSULATION KITS ASMANUFACTURED BY TRUEBRO, INC.
ADA COMPLIANT SINK (SK-3)ELKAY LUSTERTONE, MODEL ELUHAD311855, DOUBLE BOWL, 18 GAUGE TYPE 304STAINLESS STEEL, 5 1/2" DEEP, UNDERMOUNT WITH:a. CHICAGO MODEL 895-317GN8AE29VAB DECK MOUNTED SINK FAUCET WITH 8"
RIGID/SWING PLAIN END GOOSENECK SPOUT WITH 2.2 GPM LAMINAR FLOWCONTROL DEVICE IN SPOUT, 4" WRIST BLADE HANDLES AND QUATURNOPERATING CARTRIDGE;
b. LK-99 STAINLESS STEEL DRAIN OUTLET FITTING WITH CONICAL STRAINERBASKET WITH BALL BEARING LOCKING STEM AND RUBBER STOPPER AND 1 1/2"O.D. STAINLESS STEEL TAILPIECE;
c. McGUIRE CHROME PLATED HEAVY CAST BRASS P-TRAP TO WALL WITHCLEANOUT;
d. McGUIRE E-Z TURN MINI BALL VALVE STOPS WITH PREMIERE LINE HEAVYFLEXIBLE CHROME PLATED SUPPLY RISERS. (SWEAT WITH EXTENSION TOCOMPRESSION OR COMPRESSION TO COMPRESSION PREFERRED).
e. FURNISH A TEMPLATE TO THE GENERAL CONTRACTOR FOR THE ACCURATECUTTING OF THE COUNTERTOP AND COORDINATE EXACT LOCATION OFOPENING IN CASEWORK TO ENSURE SINK INSTALLATION WILL BE ADACOMPLIANT.
NOTE: INSULATE ALL EXPOSED DRAIN AND WATER PIPING ON ADA COMPLIANTFIXTURES WITH MODEL #102 E-Z LAV GUARD INSULATION KITS ASMANUFACTURED BY TRUEBRO, INC.
SINK (SK-4)ELKAY LUSTERTONE, MODEL ELUH4221L, DOUBLE BOWL, 18 GAUGE TYPE 304STAINLESS STEEL, UNDERMOUNT WITH:a. CHICAGO MODEL 895-317GN8AE29VAB DECK MOUNTED SINK FAUCET WITH 8"
RIGID/SWING PLAIN END GOOSENECK SPOUT WITH 2.2 GPM LAMINAR FLOWCONTROL DEVICE IN SPOUT, 4" WRIST BLADE HANDLES AND QUATURNOPERATING CARTRIDGE;
b. LK-99 STAINLESS STEEL DRAIN OUTLET FITTING WITH CONICAL STRAINERBASKET WITH BALL BEARING LOCKING STEM AND RUBBER STOPPER AND 1 1/2"O.D. STAINLESS STEEL TAILPIECE;
c. McGUIRE CHROME PLATED HEAVY CAST BRASS P-TRAP TO WALL WITHCLEANOUT;
d. McGUIRE E-Z TURN MINI BALL VALVE STOPS WITH PREMIERE LINE HEAVYFLEXIBLE CHROME PLATED SUPPLY RISERS. (SWEAT WITH EXTENSION TOCOMPRESSION OR COMPRESSION TO COMPRESSION PREFERRED).
e. FURNISH A TEMPLATE TO THE GENERAL CONTRACTOR FOR THE ACCURATECUTTING OF THE COUNTERTOP AND COORDINATE EXACT LOCATION OFOPENING IN CASEWORK TO ENSURE SINK INSTALLATION WILL BE ADACOMPLIANT.
NOTE: INSULATE ALL EXPOSED DRAIN AND WATER PIPING ON ADA COMPLIANTFIXTURES WITH MODEL #102 E-Z LAV GUARD INSULATION KITS ASMANUFACTURED BY TRUEBRO, INC.
ITEMNO.
FIXTURE
PLUMBING FIXTURE CONNECTIONS
MINIMUM PIPING CONNECTIONS
WASTETRAP & TRAP ARM VENT C.W. H.W.
LAVATORY (WALL HUNG - ADA)
SK-1
SK-2 1/2" 1/2"2"1-1/4" x 1-1/2"
T.W.
-
-
-
LMB-1 LAUNDRY MACHINE BOX 2" 1/2"2" 1/2"1-1/2" -
FD-1 FLOOR DRAIN - FINISHED AREAS 3" --3" NOTE 1
2" 1/2"1-1/2"1-1/2"COUNTERTOP SINK (ADA) -1/2"
3. CONNECTION SIZES ARE TO BE AS SHOWN ON SCHEDULE, EXCEPT ASOTHERWISE NOTED OR SHOWN ON PLANS.
1. WET VENT OR COMBINATION DRAIN AND VENT. REFER TO FLOOR PLAN.2. 1-1/2" UNLESS NOTED OTHERWISE.
NOTE 2
FIGURE NO.SMITHFIXTURE UNITSSYMBOL
FIGURE NO.
503061-113
5050155-330
5040114-154
D
F
E
A
B
C
WATER HAMMER ARRESTER SCHEDULE
SYMBOL
5020
5010
5005
SMITH
33-60
12-32
1-11
FIXTURE UNITS
SK-3 2" 1/2"1-1/2"1-1/2"COUNTERTOP DOUBLE BOWL SINK (ADA) -1/2"
SK-4 2" 1/2"1-1/2"1-1/2"COUNTERTOP DOUBLE BOWL SINK -1/2"
MIXING VALVE (MV-1)POWERS, MODEL LFLM-490, LEAD FREE, WITH INTEGRAL CHECKS ANDSCREENS, TEMPERATURE LOCKING MECHANISM AND UNION CONNECTIONS.
PLUMBING FIXTURE AND EQUIPMENT SCHEDULE
FLOOR DRAIN (FD-1)SMITH, FIG. 2005Y-A WITH 6" DIA. NICKEL BRONZE STRAINER. PROVIDE PROSETSYSTEMS INC. TRAP GUARD IN FLOOR DRAIN STRAINER AND DEEP SEAL P-TRAP ONDRAIN OUTLET. PROVIDE DEEP SEAL P-TRAP WITH CLEANOUT WHERE TRAPS ARELOCATED ABOVE ACCESSIBLE CEILINGS OR EXPOSED IN MECHANICAL ROOMS.
INTERIOR CLEANOUT (FLOOR TYPE)SMITH, FIG. 4028C, INSIDE CAULK OR SPEEDI-SET OUTLET WITH ROUND SCORIATEDNICKEL-BRONZE TOP AND TAPER THREAD BRONZE PLUG. PROVIDE CARPET CLAMPINGFRAME IN CARPETED FLOORS;
VENTS THRU ROOFALL VENTS PASSING THRU THE ROOF SHALL BE A MINIMUM OF 3" IN SIZE. CUT HOLESIN THE ROOF 1" IN DIAMETER LARGER THAN THE OUTSIDE DIAMETER OF THE VENTPIPE. EXTEND VENT PIPES A MINIMUM OF 12" ABOVE THE SURFACE OF THE ROOF.FLASHING FOR ALL VENTS WILL BE INSTALLED BY THE GENERAL CONTRACTOR.
NOTE: CONTRACTOR HAS THE OPTION TO RE-USE EXIST OPENINGS FROM OBSOLETEVENTS IF ADEQUATE SIZE AND LOCATED WITHIN A REASONABLE DISTANCE TO THENEW VENT THRU ROOF LOCATION AS SHOWN ON THE DRAWINGS AND DOES NOTINTERFERE WITH NEW EQUIPMENT ON ROOF.
LOCATE ALL VENTS A MINIMUM OF 15' FROM ANY AIR INTAKE OR ROOFTOP UNITINSTALLED BY THE HEATING CONTRACTOR.
FLOOR SINK (FS-1)SMITH, FIG. 3003-12 F-C(FLANGE AND FLASHING CLAMP), STAINLESS STEEL WITH DOMEBOTTOM STRAINER AND STAINLESS STEEL HALF-OPEN GRATE. OPEN PORTION OFGRATE SHALL BE POSITIONED TOWARD THE REAR OF THE PIECE OF EQUIPMENT ITSERVES. PROVIDE DEEP SEAL P-TRAP ON DRAIN OUTLET. PROVIDE DEEP SEAL P-TRAPWITH CLEANOUT WHERE TRAPS ARE LOCATED ABOVE ACCESSIBLE CEILINGS OREXPOSED IN MECHANICAL ROOMS.
PRIMARY ROOF DRAINPRIMARY DRAIN (RD-1): SMITH, FIG. 1010-C-R-CID;
LAUNDRY MACHINE BOX (LMB-1) WATTS, MODEL 2M2-DWB, DUOCLOZURE WITH WATTS DUOCLOZ SINGLE LEVER
SHUT-OFF VALVE, 2" DRAIN, TOP OR BOTTOM SUPPLIES AS REQUIRED AND WHITEFACEPLATE. PAINT FACEPLATE WITH A COLOR SELECTED BY THE ARCHITECT.PROVIDE WATTS FLEXIBLE BRAIDED STAINLESS STEEL WASHING MACHINE SUPPLYCONNECTORS, WATER HAMMER ARRESTORS ON SUPPLY PIPING AND PVC P-TRAP INWALL.
EMERGENCY EYEWASH (EEW-1)SPEAKMAN MODEL SE-570 DECK MOUNTED EYESAVER EYEWASH, SWING OPERATED,TWIN SPRAYS AND FLIP-TOP DUST COVERS. VERIFY EXACT LOCATION IN COUNTERTOPWITH OWNER INCLUDING LEFT HAND OR RIGHT HAND OPERATION AND COORDINATEEXACT LOCATION WITH SINK AND FAUCET.
ADA COMPLIANT WALL HUNG SINK (SK-2)AMERICAN STANDARD 0355.012 LUCERNE WITH:a. CHICAGO, MODEL 895-317E2805-5CP CHROME PLATED DECK MOUNT FAUCET, 5-3/8"
RIGID/SWING GOOSENECK SPOUT WITH 0.5 GPM VANDAL RESISTANT ECONO-FLOAERATOR, 4" INDEXED WRIST BLADE HANDLES AND QUATURN OPERATINGCARTRIDGES;
b. McGUIRE GRID DRAIN WITH TAILPIECE, (PROWRAP SERIES) MOLDED CLOSED CELLVINYL, ANTIMICROBIAL;
c. McGUIRE (PROWRAP SERIES) MOLDED, CLOSED CELL VINYL, ANTIMICROBIAL 'P'TRAP (1 1/4" x 1 1/2") TO WALL WITH CLEANOUT;
d. McGUIRE, MODEL LF-BV170 CHROME PLATED ALL BRASS QUARTER-TURN BALLVALVE STOPS WITH CHROME BRAIDED SUPPLIES. (SWEAT WITH EXTENSION TOCOMPRESSION OR COMPRESSION TO COMPRESSION PREFERRED);
e. SMITH, SERIES 700-M31 LAVATORY SUPPORT. BOLT SUPPORT TO FLOOR INACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS;
f. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS AND SPACING.VERIFY LOCATION ADA COMPLIANT FIXTURES SHOWN ON THE PLUMBINGDRAWINGS WITH THE ARCHITECTURAL DRAWINGS.
NOTE: INSULATE ALL EXPOSED DRAIN AND WATER PIPING ON ADA COMPLIANTFIXTURES WITH MODEL #102 E-Z LAV GUARD INSULATION KITS AS MANUFACTURED BYTRUEBRO, INC.
4"MINIMUM ABV.CROWN OF TRAP
TYP. SINK AND FAUCET
1-1/2"WASTE DOWNBELOW FLOOR
BALL VALVE STOP
1/2"SUPPLY PIPINGFROM BELOW
AIR ADMITTANCEVALVE
MV-1
EEW-1
1/2"SUPPLYPIPING
1/2" TEPIDWATER
TYPICAL PIPING HANGER DETAILNO SCALE
PIPE18 GAUGE PIPE
WITH FLARED ENDSSHIELD (MIN 12" LONG)
FIBERGLASS INSULATIONWITH PVC FITTING COVERS(REFER TO SPECIFICATIONSFOR INSULATION THICKNESS)
CLEVIS HANGER WITH THREADED ROD
REFER TO SPECIFICATIONS FORSPACING
ATTACHED TO BUILDING STRUCTURE.
TYPICAL SINK PIPING DETAILNO SCALE
GREASE INTERCEPTOR DETAIL
FULL SHEET SIZE: 30" x 42"
SHEET NUMBER
PROJECT NUMBER
REGISTRATION
CURRENT ISSUE
COPYRIGHT 2016 SFA
DRAWING HISTORY
SITE / CIVIL ENGINEER
LANDSCAPE ARCHITECT
STRUCTURAL ENGINEER
MECHANICAL / ELECTRICAL / PLUMBING
FIRE PROTECTION ENGINEER
TELECOM ENGINEER
AUDIO VISUAL ENGINEER
SECURITY ENGINEER
ACOUSTICAL ENGINEER
P8.1LVE-14179
Details and Schedules
BUCKS COUNTYCOMMUNITY COLLEGE
FOUNDERS HALLRENOVATIONS
FOUNDERS HALL RENOVATIONS
100% CD Submission -
NOT FOR CONSTRUCTION08/19/2016
N/A
N/A
BARRY ISETT ASSOCIATES85 PA-100,
Allentown, PA 18106
LEHIGH VALLEY ENGINEERING1 W Broad St #500,Bethlehem, PA 18018
LEHIGH VALLEY ENGINEERING
N/A
N/A
N/A
N/A
NO. ISSUE DATE: DESCRIPTION